RAD-MIB

File: RAD-MIB.mib (1855240 bytes)

Imported modules

FDDI-SMT73-MIB SNMP-REPEATER-MIB MAU-MIB
SNMPv2-SMI SNMPv2-TC ATM-TC-MIB
ATM-MIB FRNETSERV-MIB Q-BRIDGE-MIB
ATMF-CES IF-MIB IMA-MIB
DS1-MIB DS3-MIB PerfHist-TC-MIB
MULTI-MEDIA-REG-TC SNMP-FRAMEWORK-MIB ISDN-MIB
FR-ATM-PVC-SERVICE-IWF-MIB HDSL2-SHDSL-LINE-MIB RFC1381-MIB

Imported symbols

fddimibPORTPCMState rptrGroupOperStatus rptrPortOperStatus
rpMauMediaAvailable Integer32 Counter32
TimeTicks enterprises IpAddress
Gauge32 OBJECT-TYPE MODULE-IDENTITY
NOTIFICATION-TYPE OBJECT-IDENTITY TimeStamp
TAddress DisplayString RowStatus
DateAndTime TruthValue AtmTrafficDescrParamIndex
atmVplVpi atmVclVpi atmVclVci
aal5VccVpi aal5VccVci atmVclEntry
aal5VccEntry frPVCEndptDLCIIndex VlanIndex
atmfCESCbrIndex atmfCESConfEntry InterfaceIndex
ifAlias ifIndex imaGroupIndex
imaLinkIfIndex imaGroupFailureStatus dsx1LineStatus
dsx1LineStatusLastChange dsx1CurrentIndex dsx1LineIndex
dsx1IntervalIndex dsx1IntervalNumber dsx1LoopbackStatus
dsx1TotalIndex dsx3LineStatus dsx3LoopbackStatus
PerfCurrentCount PerfIntervalCount PerfTotalCount
MmTAddressTag MmEndpointID MmAliasAddress
MmGatekeeperID MmAliasTag SnmpAdminString
isdnSignalingEntry frAtmIwfConnectionEntry hdsl2ShdslEndpointCurrEntry
hdsl2ShdslInvIndex hdsl2ShdslEndpointSide hdsl2ShdslSpanConfProfileEntry
IfIndexType

Defined Objects

rad 1.3.6.1.4.1.164
RAD MIB, version 485.
MODULE-IDENTITY    

radTokenRing 1.3.6.1.4.1.164.1
OBJECT IDENTIFIER    

trGen 1.3.6.1.4.1.164.1.1
OBJECT IDENTIFIER    

agnRR 1.3.6.1.4.1.164.1.1.1
OBJECT IDENTIFIER    

agnRRcoprocHwVersion 1.3.6.1.4.1.164.1.1.1.1
ASCII string for description and display of the CML\IB hardware version. If the entry is not applicable, it will display the string -NOT APPLICABLE-
OBJECT-TYPE    
  DisplayString  

agnRRrecMode 1.3.6.1.4.1.164.1.1.1.2
The manager station can assist the agent in the autorecovery process by setting this value to SLOW(1). This value indicates the presence of old modules within the radring hub. Autorecovery process will be faster for new modules. However it might fail if set to FAST(2) and old modules are inserted.
OBJECT-TYPE    
  INTEGER unknown(1), slow(2), fast(3), notSupported(4)  

agnRRmaskIBMalrt 1.3.6.1.4.1.164.1.1.1.3
When this object is set to the value of Enabled(3), Agent-traps that are not masked will also be sent to the IBM LAN manager using IBM's Alert Transport Service Protocol. This object is applicable only for TR agents.
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), enabled(3)  

agnRRResetConfig 1.3.6.1.4.1.164.1.1.1.4
Setting the value to ON(3)is interpreted as a reset command for the agent NV Ram. When reset process is ended, a trap will be issued. If the entry is not applicable, The value notSupported will be read.
OBJECT-TYPE    
  INTEGER off(2), on(3), notSupported(4)  

agnRRSwReset 1.3.6.1.4.1.164.1.1.1.5
Setting the value to ON(3)is interpreted as a software reset command for the agent. When reset process is ended, a trap will be issued.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnRRRingReportMngr 1.3.6.1.4.1.164.1.1.1.6
Setting the value to ON(3) is interpreted as assigning the duty of Ring Report Manager on the agent
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnRRSubSysCommState 1.3.6.1.4.1.164.1.1.1.7
This attribute indicates the status of communication between the two agent's processors. The communication is failed when the CML/NM card is removed
OBJECT-TYPE    
  INTEGER failed(2), ok(3), notSupported(4)  

ringTR 1.3.6.1.4.1.164.1.1.2
OBJECT IDENTIFIER    

ringResetStatistics 1.3.6.1.4.1.164.1.1.2.1
Setting the value of this attribute to ON(3) resets all the inband statistics and error counters.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

ringCurrentTraffic 1.3.6.1.4.1.164.1.1.2.2
Momentary traffic for the last time interval. The traffic is expressed in percents of the maximum Tokenring traffic .
OBJECT-TYPE    
  Integer32  

ringPeakTraffic 1.3.6.1.4.1.164.1.1.2.3
Maximal traffic value since last reset of Agent or statistics. Expressed in percents of the maximum Tokenring traffic.
OBJECT-TYPE    
  Integer32  

ringTrafficTreshold 1.3.6.1.4.1.164.1.1.2.4
Traffic threshold value. When reached, a trap will be sent to the management console. Expressed in percents of the maximum Tokenring traffic
OBJECT-TYPE    
  Integer32  

ringLineErrCnt 1.3.6.1.4.1.164.1.1.2.5
This counter is incremented when a frame or token is copied or repeated by any of the stations on the ring, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame.
OBJECT-TYPE    
  Counter32  

ringLineErr 1.3.6.1.4.1.164.1.1.2.6
This counter is incremented when a frame or token is copied or repeated by any of the stations on the ring, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame.
OBJECT-TYPE    
  Integer32  

ringBurstErrCnt 1.3.6.1.4.1.164.1.1.2.7
This counter is incremented when any of the stations on the ring detects the absence of transitions for five half-bit timers (burst-five error).
OBJECT-TYPE    
  Counter32  

ringBurstErr 1.3.6.1.4.1.164.1.1.2.8
This counter is incremented when any of the stations on the ring detects the absence of transitions for five half-bit timers (burst-five error).
OBJECT-TYPE    
  Integer32  

ringACFCErrCnt 1.3.6.1.4.1.164.1.1.2.9
This counter is incremented when any of the stations on the ring receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly.
OBJECT-TYPE    
  Counter32  

ringACFCErr 1.3.6.1.4.1.164.1.1.2.10
This counter is incremented when any of the stations on the ring receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly.
OBJECT-TYPE    
  Integer32  

ringTotErrCnt 1.3.6.1.4.1.164.1.1.2.11
The total of the above described errors
OBJECT-TYPE    
  Counter32  

ringTotErr 1.3.6.1.4.1.164.1.1.2.12
The total of the above described errors
OBJECT-TYPE    
  Integer32  

ringTotErrThreshold 1.3.6.1.4.1.164.1.1.2.13
The threshold value of the total of the above described errors.When the threshold is reached a trap indicating the status of the ring (SOFT ERROR)will be sent to the management station
OBJECT-TYPE    
  Integer32  

ringStatus 1.3.6.1.4.1.164.1.1.2.14
Describes the status of the LAN segment the agent is attached to: Normal(2) - The LAN segment is operating normally SoftError(3) - The Token ring LAN segment (ring) is experiencing intermittent failures that temporarily harm the ring's performance and cause data to be transmitted more than ones. Beaconing(4) - The ring is not operative; no data is transmitted.
OBJECT-TYPE    
  INTEGER unknown(1), normal(2), softError(3), beacon(4)  

ringConfigMsg 1.3.6.1.4.1.164.1.1.2.15
Full configuration message coded in internal RAD application format. This entry describes ring information.
OBJECT-TYPE    
  OCTET STRING  

ringCurrentTrafficCnt 1.3.6.1.4.1.164.1.1.2.16
Momentary traffic for the last time interval. The traffic is expressed as bits per second.
OBJECT-TYPE    
  Counter32  

segTR 1.3.6.1.4.1.164.1.1.3
OBJECT IDENTIFIER    

segTRTable 1.3.6.1.4.1.164.1.1.3.1
Segments.
OBJECT-TYPE    
  SEQUENCE OF  
    SegTREntry

segTREntry 1.3.6.1.4.1.164.1.1.3.1.1
An entry in table segTRTable.
OBJECT-TYPE    
  SegTREntry  

segTRID 1.3.6.1.4.1.164.1.1.3.1.1.1
Segment unique identification number (internal). It is the extreme left slot, marking the beginning of the segment.
OBJECT-TYPE    
  Integer32 1..20  

segTRLastSlot 1.3.6.1.4.1.164.1.1.3.1.1.2
Location of the right most slot marking the end of the segment. In the RADring hub it is slot number 20 or the slot where end of segment module is inserted or the slot before a beginning of a new segment. ( End of segment module could be one with termination on or TIO, TFR, TCR etc.)
OBJECT-TYPE    
  Integer32  

segTRFirstSlot 1.3.6.1.4.1.164.1.1.3.1.1.3
Location of the left most slot marking the beginning of the segment. In the RADring hub it is slot number 1 or the slot number following the end of segment module, or where a repeater or TIO is inserted.
OBJECT-TYPE    
  Integer32  

segTRStatus 1.3.6.1.4.1.164.1.1.3.1.1.4
Describes the status of the segment : Normal(3) - The segment is operating normally Beaconing(2) - The ring is not operative; no data is transmitted. Segment without inband module within its limit will display Unknown(1). This entry is specially usefull when the hub is configured with multiple segments and each segment is part of another net
OBJECT-TYPE    
  INTEGER unknown(1), beaconing(2), normal(3)  

moduleTR 1.3.6.1.4.1.164.1.1.4
OBJECT IDENTIFIER    

mdlTRTable 1.3.6.1.4.1.164.1.1.4.1
Modules parameters structure contains general information about the modules.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlTREntry

mdlTREntry 1.3.6.1.4.1.164.1.1.4.1.1
An entry in table mdlTRTable.
OBJECT-TYPE    
  MdlTREntry  

mdlTRID 1.3.6.1.4.1.164.1.1.4.1.1.1
The slot number where the module is inserted. Can not be greater than chNoSlot
OBJECT-TYPE    
  Integer32  

mdlTRSegID 1.3.6.1.4.1.164.1.1.4.1.1.2
The segment number where the module belongs to. One of the segTRID values.
OBJECT-TYPE    
  Integer32  

mdlTRType 1.3.6.1.4.1.164.1.1.4.1.1.3
Indicates the type of the module connected at the specified slot number.
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), tl4s(3), tl4su(4), tl4sd(5), tl4cx(6), tl4u(7), tl2edu(8), tl2eds(9), tl2edsu(10), tl2f(11), tja(12), tio(13), tfr(14), tfc1(15), tfc2(16), tcr(17), tl4au(18), tl4as(19), tl4asd(20), tl4asu(21), tre1d(22), tre(23), tre8d(24), stc1(25), stc2(26), ftc(27), cmlib(28), tl2fsat(29), nonTR(30), tau(31), rmu(32)  

mdlTRHwVer 1.3.6.1.4.1.164.1.1.4.1.1.4
ASCII string for description and display of the module's hardware version, as it is known by the module's software. A manager can record his own hardware upgrade.
OBJECT-TYPE    
  DisplayString  

mdlTRSwVer 1.3.6.1.4.1.164.1.1.4.1.1.5
ASCII string for description and display of the module's software version. A value of NOT APPLICABLE will be recorded for module having no independent processor.
OBJECT-TYPE    
  DisplayString  

mdlTRTotalNoOfPrt 1.3.6.1.4.1.164.1.1.4.1.1.6
This entry describes the number of possible ports/lobes/links connection in the module (not all ports hardware should be active) .
OBJECT-TYPE    
  Integer32  

mdlTRSpecific 1.3.6.1.4.1.164.1.1.4.1.1.7
Object identifier of entity containing additional information regarding this instance. This entry is type specific.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

prtTR 1.3.6.1.4.1.164.1.1.5
OBJECT IDENTIFIER    

prtTRTable 1.3.6.1.4.1.164.1.1.5.1
TReral port table for any media type.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtTREntry

prtTREntry 1.3.6.1.4.1.164.1.1.5.1.1
An entry in table prtTRTable.
OBJECT-TYPE    
  PrtTREntry  

prtTRModuleID 1.3.6.1.4.1.164.1.1.5.1.1.1
A unique identifier of the module(slot no.)this port is attached to.
OBJECT-TYPE    
  Integer32  

prtTRID 1.3.6.1.4.1.164.1.1.5.1.1.2
A unique identifier of the port within its module.
OBJECT-TYPE    
  Integer32  

prtTRFunctionality 1.3.6.1.4.1.164.1.1.5.1.1.3
Describes the functionality of the port in a Token ring topology or other implementations.
OBJECT-TYPE    
  INTEGER unknown(1), ringin(2), ringout(3), satellite(4), lobe(5), link(6), tja(7), none(8), smart-port(9)  

prtTRConnectorType 1.3.6.1.4.1.164.1.1.5.1.1.4
Type of hardware connector in the port.
OBJECT-TYPE    
  INTEGER notApplicable(1), idc(2), rj45(3), srj45(4), db9(5), bnc(6), foSt(7), db25(8)  

prtTRAdminCmd 1.3.6.1.4.1.164.1.1.5.1.1.5
By setting this attribute to DISABLE(2) or SHORT(4) the management station can force this lobe/port/link-connection to be removed and block any access to the network via this lobe/port/link. It is not mandatory that a certain lobe/port/link will support all the enumerated states. The state of the lobe/port/link is type specific and indicated within the specific group
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3), short(4), normal(5)  

prtTRActiveState 1.3.6.1.4.1.164.1.1.5.1.1.6
This attribute describes the electrical or optical activity state of a lobe or the state of a port. Certain values may not be applicable in some cases
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3), standby(4)  

prtTRTrapMaskEnable 1.3.6.1.4.1.164.1.1.5.1.1.7
When this attribute is set to OFF by the management console the agent starts sending the unmasked traps related to this port. Otherwise no traps from this port are sent.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtTRstatus 1.3.6.1.4.1.164.1.1.5.1.1.8
This attribute indicates the status of this lobe/port connection: DISABLED - (2) to (6) indicates the reason for the disabled state. INSERTED - (7)indicates that the lobe hardware inserts this lobe into the ring , thus it becomes part of the ring. BYPASS - (8)indicates that the ring bypasses this lobe and the lobe hardware provides loopback connection towards the station for media test purposes. FORCEDLOOP - (9) indicates the port is in a loopback state and the main ring is connected to the backup path. TRUNKFAIL - (10) indicates that the ring connection is broken for a repeater, converter or a cable protector. NORMAL - (11) indicates the port is in normal condition. It is not mandatory that a certain lobe/port will support all the enumerated states.
OBJECT-TYPE    
  INTEGER unknown(1), disabledManuall(2), disabledAutorec(3), disabledSecurity(4), disableAuto(5), disableFlip(6), inserted(7), bypass(8), forcedloop(9), trunkfail(10), normal(11)  

prtTRCableProtectEnable 1.3.6.1.4.1.164.1.1.5.1.1.9
The value of this attribute determines activation of the cable-fault protection mechanism of TCR and the optical link mechanism of TFR and TFC .
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3), inhibit(4)  

prtTRCableState 1.3.6.1.4.1.164.1.1.5.1.1.10
The value of this attribute determines the cable status of TCR and the optical link mechanism of TFR and TFC .
OBJECT-TYPE    
  INTEGER unknown(1), failed(2), normal(3), remoteFailed(4)  

prtTRMACAddress 1.3.6.1.4.1.164.1.1.5.1.1.11
The value of this object is the specific MAC address of this interface which uniquely identifies this Interface on a ring.
OBJECT-TYPE    
  MacAddress  

prtTRSpecific 1.3.6.1.4.1.164.1.1.5.1.1.12
Object identifier of entity containing additional information regarding this instance. This entry is type specific.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

prtTRMacAddressTable 1.3.6.1.4.1.164.1.1.5.2
.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtTRMacAddressEntry

prtTRMacAddressEntry 1.3.6.1.4.1.164.1.1.5.2.1
An entry in table prtTRMacAddressTable.
OBJECT-TYPE    
  PrtTRMacAddressEntry  

prtTRMacAddressModuleID 1.3.6.1.4.1.164.1.1.5.2.1.1
A unique identifier of the module(slot no.)this port is attached to.
OBJECT-TYPE    
  Integer32  

prtTRMacAddressPortID 1.3.6.1.4.1.164.1.1.5.2.1.2
A unique identifier of the port within its module.
OBJECT-TYPE    
  Integer32  

prtTRMacAddressID 1.3.6.1.4.1.164.1.1.5.2.1.3
A identifier of the MAC address in the list according to the ring order
OBJECT-TYPE    
  Integer32 1..250  

prtTRMACAddressValue 1.3.6.1.4.1.164.1.1.5.2.1.4
MAC address from the list of addresses connected to this port
OBJECT-TYPE    
  MacAddress  

radRing 1.3.6.1.4.1.164.1.2
OBJECT IDENTIFIER    

chasRR 1.3.6.1.4.1.164.1.2.1
OBJECT IDENTIFIER    

chType 1.3.6.1.4.1.164.1.2.1.1
This value indicates which type of enclosure the Rad agent is managing. The default value will be RadRing
OBJECT-TYPE    
  DisplayString  

chNoSlot 1.3.6.1.4.1.164.1.2.1.2
This value indicates the number of manageable slots in the chassis. Not all slots must be occupied.
OBJECT-TYPE    
  Integer32  

chPSPrimary 1.3.6.1.4.1.164.1.2.1.3
This attribute indicates the status of the main (primary) power supply unit
OBJECT-TYPE    
  INTEGER unknown(1), off(2), fault(3), active(4), recovered(5), none(6)  

chPSSecondary 1.3.6.1.4.1.164.1.2.1.4
This attribute indicates the status of the secondary power supply unit
OBJECT-TYPE    
  INTEGER unknown(1), off(2), fault(3), active(4), recovered(5), none(6)  

chTemperature 1.3.6.1.4.1.164.1.2.1.5
This attribute indicates if the internal hub temperature exceeded the permissible maximum
OBJECT-TYPE    
  INTEGER ok(1), exceed(2)  

chEtMainClock 1.3.6.1.4.1.164.1.2.1.6
This attribute indicates the status of Eternet repeater main clock in RadRingII hub
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), fault(3)  

chEtSecClock 1.3.6.1.4.1.164.1.2.1.7
This attribute indicates the status of Eternet repeater secondary clock in RadRingII hub
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), fault(3)  

segRR 1.3.6.1.4.1.164.1.2.2
OBJECT IDENTIFIER    

segRRSecurityTable 1.3.6.1.4.1.164.1.2.2.1
RADRing segments' specific information
OBJECT-TYPE    
  SEQUENCE OF  
    SegRRSecEntry

segRRSecEntry 1.3.6.1.4.1.164.1.2.2.1.1
An entry in table segRRSecurityTable.
OBJECT-TYPE    
  SegRRSecEntry  

segRRID 1.3.6.1.4.1.164.1.2.2.1.1.1
Segment unique identification number (internal). It is the extreme left slot, marking the beginning of the segment. TR segment no.: 1 .. 20 Ethernet segment no.: 21.
OBJECT-TYPE    
  Integer32 1..21  

segRRSecID 1.3.6.1.4.1.164.1.2.2.1.1.2
Segment's security unique identification number
OBJECT-TYPE    
  Integer32  

segRRSecEnable 1.3.6.1.4.1.164.1.2.2.1.1.3
This entry indicates whether the specific segment's security is active or not
OBJECT-TYPE    
  INTEGER off(2), on(3)  

segRRSecurityPattern 1.3.6.1.4.1.164.1.2.2.1.1.4
A six-octet (48 bit) pattern, where the masked bits of segTRSecurityMask need to match the MAC address of each port within the segment. A Value of all-zeros indicates no security.
OBJECT-TYPE    
  MacAddress  

segRRSecurityMask 1.3.6.1.4.1.164.1.2.2.1.1.5
Mask of the allowed MAC address that can be connected through the ports within the segment
OBJECT-TYPE    
  MacAddress  

moduleRR 1.3.6.1.4.1.164.1.2.3
OBJECT IDENTIFIER    

mdlRRTable 1.3.6.1.4.1.164.1.2.3.1
RADRing specific modules' information
OBJECT-TYPE    
  SEQUENCE OF  
    MdlRREntry

mdlRREntry 1.3.6.1.4.1.164.1.2.3.1.1
An entry in table mdlRRTable.
OBJECT-TYPE    
  MdlRREntry  

mdlRRid 1.3.6.1.4.1.164.1.2.3.1.1.1
Unique number to identify the module. It indicates the slot number the module is inserted in.
OBJECT-TYPE    
  Integer32 1..20  

mdlRRTLRstatus 1.3.6.1.4.1.164.1.2.3.1.1.2
This entry specifies the status of the setup on the TL-2/Exx modules. When the value is ON, lobe one is the only active lobe. This entry will have the value UNKNOWN for all other modules
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

mdlRRtermination 1.3.6.1.4.1.164.1.2.3.1.1.3
Attribute describing the termination state as set by the switches on the lobe modules
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

mdlRRReset 1.3.6.1.4.1.164.1.2.3.1.1.4
When this object is set to the value of ON(3), the module performs software reset. Upon completion, a trap will be issued to the management station and the value will be set to OFF. This entry will have the value of UNKNOWN (1) for modules without independent processors. This command should be masked for the agent module
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

mdlRRLed 1.3.6.1.4.1.164.1.2.3.1.1.5
This entry specifies the LEDs status in the module . Each led will be represented by 4 bits where the first 2 bits will specify the status (NA, OFF, ON, BLINK), and the next two bits will specify the color (RED, GREEN, YELLOW)
OBJECT-TYPE    
  OCTET STRING  

mdlRRSpeed 1.3.6.1.4.1.164.1.2.3.1.1.6
Attribute describing the bandwidth of the media as set by the module switches.
OBJECT-TYPE    
  INTEGER unknown(1), fourMegabit(2), sixteenMegabit(3), tenMegabit(4)  

mdlRRMngAutoDis 1.3.6.1.4.1.164.1.2.3.1.1.7
Attribute describing the setup of the MNG switch on the TL- Active cards. Value ON indicates the ability of activating the auto-disable mechanism of the card via management command. Value OFF indicates that the activation of the auto-disable mechanism of the card is according to the switch setting.In this case the mdlRRAutodisable will not be available for write operation. Applicable to Token Ring cards only. Replaced by mdlRRMngState.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

mdlRRAutodisable 1.3.6.1.4.1.164.1.2.3.1.1.8
This attribute can be set by the manager if the value of mdlRRMngAutoDis is ON. It controls the behavior of the Active cards regarding the Auto-disable mechanism. All ports will be in the same mode. Applicable to Token Ring cards only.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

mdlRRConfigMsg 1.3.6.1.4.1.164.1.2.3.1.1.9
Full configuration message coded in internal RAD application format. This entry describes module' configuration.
OBJECT-TYPE    
  OCTET STRING  

mdlRRMngState 1.3.6.1.4.1.164.1.2.3.1.1.10
This entry indicates the setting of the module's switches. ENABLE means that the module can accept management commands.
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3)  

mdlRRType 1.3.6.1.4.1.164.1.2.3.1.1.11
Indicates the type of the module installed in the specified slot number.
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), tl4s(3), tl4su(4), tl4sd(5), tl4cx(6), tl4u(7), tl2edu(8), tl2eds(9), tl2edsu(10), tl2f(11), tja(12), tio(13), tfr(14), tfc1(15), tfc2(16), tcr(17), tl4au(18), tl4as(19), tl4asd(20), tl4asu(21), tre1d(22), tre(23), tre8d(24), stc1(25), stc2(26), ftc(27), cmlib(28), tl2fsat(29), taV24(30), taV11(31), wangVs(32), ta3x74(33), ta3x(34), sat-asu(35), sat-asd(36), sat-su(37), sat-sd(38), ep8t(39), ep4taui(40), ep4t2fl(41), ep4tfl(42), ep4fl(43), epr8t(45), epr4taui(46), epr4t2fl(47), epr4tfl(48), epr4fl(49), tl2fm(51), ftc2(53), mlbt(54), mlbtf(55), ftbDfo(56), ftbSfo(57), mbe8d(58), mbe1d(59), cmlibE(60)  

mdlRRHwVer 1.3.6.1.4.1.164.1.2.3.1.1.12
ASCII string for description and display of the module's hardware version, as it is known by the module's software. A manager can record his own hardware upgrade.
OBJECT-TYPE    
  DisplayString  

mdlRRSwVer 1.3.6.1.4.1.164.1.2.3.1.1.13
ASCII string for description and display of the module's software version. A value of NOT APPLICABLE will be recorded for a module having no independent processor.
OBJECT-TYPE    
  DisplayString  

mdlRRSpecific 1.3.6.1.4.1.164.1.2.3.1.1.14
Object identifier of entity containing additional information regarding this instance. This entry is module type specific.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

mdlIBTable 1.3.6.1.4.1.164.1.2.3.2
Additional parameters that can be monitored for a segment with an inband module. Module specific for Token Ring
OBJECT-TYPE    
  SEQUENCE OF  
    MdlIBEntry

mdlIBEntry 1.3.6.1.4.1.164.1.2.3.2.1
An entry in table mdlIBTable.
OBJECT-TYPE    
  MdlIBEntry  

mdlIBid 1.3.6.1.4.1.164.1.2.3.2.1.1
Unique number to identify the CML\IB module. It indicates the slot number the module is inserted in
OBJECT-TYPE    
  Integer32 1..20  

mdlIBsegID 1.3.6.1.4.1.164.1.2.3.2.1.2
Unique number to identify the segment where the CML\IB module is inserted. It is one of the segTRID values.
OBJECT-TYPE    
  Integer32 1..20  

mdlIBCorrelationEnable 1.3.6.1.4.1.164.1.2.3.2.1.3
When set to ON(3), the in-band agent should perform correlation each time a station enters/leaves the segment.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlIBAutorecEnable 1.3.6.1.4.1.164.1.2.3.2.1.4
When set to ON(3), the in-band agent should perform autorecovery each time a beacon status is detected.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlIBAutorecResult 1.3.6.1.4.1.164.1.2.3.2.1.5
When autorecovery is completed the result will be reported (3)..(7). While in autorecovery process, started(2) will be reported. Before autorecovery process, notStarted(1) will be reported.
OBJECT-TYPE    
  INTEGER notStarted(1), started(2), segmentOk(3), segmentFixed(4), segmentClosed(5), failed(6), hubProblem(7)  

mdlIBcommand 1.3.6.1.4.1.164.1.2.3.2.1.6
When this object is set to the value of open(2), the station should go into the open state. The progress and success of this command is given by the values of the object mdlIBstate. When this object is set to the value of reset(3), then the station should do a reset. On a reset, all MIB counters should retain their values, if possible. Other side effects depend on the hardware chip set. When this object is set to the value of close(4), the station should go into the closed state by removing itself from the ring. Setting this object to a value of no-op(1) has no effect. For read operation, this object has always a value of no-op(1). It is not permitted to apply this command on an agent module.
OBJECT-TYPE    
  INTEGER noOp(1), open(2), reset(3), close(4)  

mdlIBstate 1.3.6.1.4.1.164.1.2.3.2.1.7
The current adapter status, which can be used to diagnose fluctuating problems.
OBJECT-TYPE    
  INTEGER unknown(1), opened(2), closed(3), opening(4), closing(5), badParam(6), lobeFailed(7), signalLoss(8), insertionTimeout(9), ringFailed(10), beaconning(11), duplicateMac(12), requestFailed(13), removeReceived(14), budFailure(15), initFailure(16)  

mdlIBagnt 1.3.6.1.4.1.164.1.2.3.2.1.8
Indicates whether the specific inband module serves as: - Active hub agent - (on) - Ring Monitor (for TR module only) - (off) - Standby agent - (standBy)
OBJECT-TYPE    
  INTEGER off(2), on(3), standBy(4)  

mdlIBIpAddress 1.3.6.1.4.1.164.1.2.3.2.1.9
Indicates IP address of the module if the module serves as an agent of itself.
OBJECT-TYPE    
  IpAddress  

mdlIBLocalMacAddr 1.3.6.1.4.1.164.1.2.3.2.1.10
The value of this object is the specific MAC address of this interface which uniquely identifies this interface on a ring.It is the address set by the management and upon request it will replace the burn in address. Non-canonical format.
OBJECT-TYPE    
  MacAddress  

mdlIBLocalAddrStatus 1.3.6.1.4.1.164.1.2.3.2.1.11
The value of this object specifies whether the specific MAC address of this interface was set by the local management or it is the burn-in address in use.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

mdlIBbrnInMacAddr 1.3.6.1.4.1.164.1.2.3.2.1.12
The value of this object is the specific Burn-in MAC address of this interface which uniquely identifies this interface on a ring. Non-canonical format.
OBJECT-TYPE    
  MacAddress  

mdlIBTrapMaskEnable 1.3.6.1.4.1.164.1.2.3.2.1.13
When this attribute is set to OFF by the management console, the agent starts sending the unmasked traps related to this module. Otherwise, no traps are sent by this module.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlBRGTable 1.3.6.1.4.1.164.1.2.3.3
Special modules such as bridges/converters that are within the hub
OBJECT-TYPE    
  SEQUENCE OF  
    MdlBRGEntry

mdlBRGEntry 1.3.6.1.4.1.164.1.2.3.3.1
An entry in table mdlBRGTable.
OBJECT-TYPE    
  MdlBRGEntry  

mdlBRGid 1.3.6.1.4.1.164.1.2.3.3.1.1
Unique number to identify the module. It indicates the slot number the module is inserted in.
OBJECT-TYPE    
  Integer32 1..20  

mdlBRGReady 1.3.6.1.4.1.164.1.2.3.3.1.2
This entry will have the value ON when packets can be transferred in the TRE module. The value UNKNOWN will be used for all other modules where this characteristic is not applicable
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3), blink(4)  

mdlBRGStatus 1.3.6.1.4.1.164.1.2.3.3.1.3
This entry specifies the status of operation of the STC or FTC modules. For other modules this value will read NOAP
OBJECT-TYPE    
  DisplayString  

mdlBRGLocation 1.3.6.1.4.1.164.1.2.3.3.1.4
This entry indicates the configuration mode: - for the TRE bridge (main/remote) - for MLB-T, MLBT-F (main/secondary)
OBJECT-TYPE    
  INTEGER unknown(1), main(2), remote(3), secondary(4)  

mdlBRGIpAddress 1.3.6.1.4.1.164.1.2.3.3.1.5
Indicates IP address of the module if the module serves as an agent of itself. For all other modules the IP value will be 0.0.0.0
OBJECT-TYPE    
  IpAddress  

mdlBRGMacAddr 1.3.6.1.4.1.164.1.2.3.3.1.6
The value of this object is the specific MAC address of this interface which uniquely identifies this interface on a ring.
OBJECT-TYPE    
  MacAddress  

mdlBRGAdapterState 1.3.6.1.4.1.164.1.2.3.3.1.7
The current adapter status, which can be used to diagnose fluctuating problems. This object is applicable only for TR bridges with adapter. The value 'unknown' will be used for other module types.
OBJECT-TYPE    
  INTEGER unknown(1), opened(2), closed(3), opening(4), closing(5), badParam(6), lobeFailed(7), signalLoss(8), insertionTimeout(9), ringFailed(10), beaconning(11), duplicateMac(12), requestFailed(13), removeReceived(14), budFailure(15), initFailure(16)  

mdlBRGBypassSw 1.3.6.1.4.1.164.1.2.3.3.1.8
This entry is applicable only for FTB-D/FO module. It describes the status of the Bypass Switch. The value UNKNOWN will be used for all other modules where this characteristic is not applicable
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

mdlMMTable 1.3.6.1.4.1.164.1.2.3.4
Special 'WAN' modules that are within the RadRing hub
OBJECT-TYPE    
  SEQUENCE OF  
    MdlMMEntry

mdlMMEntry 1.3.6.1.4.1.164.1.2.3.4.1
An entry in table mdlMMTable.
OBJECT-TYPE    
  MdlMMEntry  

mdlMMid 1.3.6.1.4.1.164.1.2.3.4.1.1
Unique number to identify the module. It indicates the slot number the module is inserted in.
OBJECT-TYPE    
  Integer32 1..20  

mdlMMBertCmd 1.3.6.1.4.1.164.1.2.3.4.1.2
Setting this Object to ON, will start BERT test on all the channels that are currently in Remote Loop. If the value of mdlRRMngState is disabled, this parameter is read-only and reflects the module jumper setting.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

mdlETTable 1.3.6.1.4.1.164.1.2.3.5
'Ethernet' modules that are within the hub
OBJECT-TYPE    
  SEQUENCE OF  
    MdlETEntry

mdlETEntry 1.3.6.1.4.1.164.1.2.3.5.1
An entry in table mdlETTable.
OBJECT-TYPE    
  MdlETEntry  

mdlETid 1.3.6.1.4.1.164.1.2.3.5.1.1
Unique number to identify the module. It indicates the slot number the module is inserted in. It is the same as rptrGroupIndex in the Repeater MIB
OBJECT-TYPE    
  Integer32 1..20  

mdlETSAmode 1.3.6.1.4.1.164.1.2.3.5.1.2
Setting this Object to ON, will change the mode of operation of the Ethernet card to a stand alone operation mode. It will disconnect the card from the repeater bus. The rptrGroupOperStatus parameter in the Repeater MIB is changed to other(1). The parameter is read-only when the value of mdlRRMngState is disabled
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

prtRR 1.3.6.1.4.1.164.1.2.4
OBJECT IDENTIFIER    

prtRRTable 1.3.6.1.4.1.164.1.2.4.1
RADRing specific port information
OBJECT-TYPE    
  SEQUENCE OF  
    PrtRREntry

prtRREntry 1.3.6.1.4.1.164.1.2.4.1.1
An entry in table prtRRTable.
OBJECT-TYPE    
  PrtRREntry  

prtRRmdlID 1.3.6.1.4.1.164.1.2.4.1.1.1
A unique identifier of the module,(slot no.),this port is attached to.
OBJECT-TYPE    
  Integer32  

prtRRID 1.3.6.1.4.1.164.1.2.4.1.1.2
A unique identifier of the port within its module.
OBJECT-TYPE    
  Integer32  

prtRRSecurityState 1.3.6.1.4.1.164.1.2.4.1.1.3
This entry indicates whether a security check can be performed on the specific port. This value is directly related to the presence of an inband module in the segment where the port belongs to and to activation of the correlation process.
OBJECT-TYPE    
  INTEGER notactive(1), active(2)  

prtRRSecurityEnable 1.3.6.1.4.1.164.1.2.4.1.1.4
This value indicates whether a security check should be performed. Setting this value to ON(3) will activate the security mechanism if and only if, the value of prtRRSecurityState is ACTIVE.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtRRSecurityMask 1.3.6.1.4.1.164.1.2.4.1.1.5
Mask of the allowed MAC address that can be connected through this port. The security of the individual port overwrites the security of the segment where the port belongs to
OBJECT-TYPE    
  MacAddress  

prtRRSecurityPattern 1.3.6.1.4.1.164.1.2.4.1.1.6
A six-octet(48 bit) pattern, where the masked bits of prtRRSecurityMask should match the MAC address.
OBJECT-TYPE    
  MacAddress  

prtRRJitterAttenEnable 1.3.6.1.4.1.164.1.2.4.1.1.7
The value of this attribute determines activation of the jitters Attenuation mechanism of repeater's port .
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

prtRRConfigMsg 1.3.6.1.4.1.164.1.2.4.1.1.8
Full configuration message coded in internal RAD application format. This entry describes port' configuration.
OBJECT-TYPE    
  OCTET STRING  

prtRRFlipAutoDisable 1.3.6.1.4.1.164.1.2.4.1.1.9
Attribute describing the control on the flipping mechanism of a lobe . Value ON indicates the ability of the lobe to auto disable itself when flipping occur. Value OFF indicates that the auto disable mechanism should not be activated and the lobe should stay in a flipping state. This attribute applies on selected lobes (tl-2/f, or tl-2/fsat)
OBJECT-TYPE    
  INTEGER noApplicable(1), off(2), on(3)  

prtRRSecurityMask2 1.3.6.1.4.1.164.1.2.4.1.1.10
Mask of the allowed MAC address that can be connected through this port. The security of the individual port overwrites the security of the segment where the port belongs to
OBJECT-TYPE    
  MacAddress  

prtRRSecurityPattern2 1.3.6.1.4.1.164.1.2.4.1.1.11
A six-octet(48 bit) pattern: where the masked bits of prtRRSecurityMask2 should match the MAC address.
OBJECT-TYPE    
  MacAddress  

prtRRMode 1.3.6.1.4.1.164.1.2.4.1.1.12
Indicates the port status of rr-sat card after the communication is broken. When configured to smart-port, the port disables itself when there is no management communication with attachment. interRptrPort - this port is used to connect an external repeater. No security can be set for this port. MAC Address is set to 0. No traps 'MAC Address changed' are generated. multiConnPort - this port is used for connection of external 4 port repeater. 8 securities per port exist. MAC Address is set to 0. No traps 'MAC Address changed' are generated.
OBJECT-TYPE    
  INTEGER noApplicable(1), smart-port(2), port(3), interRptrPort(4), multiConnPort(5)  

prtRRAttachment 1.3.6.1.4.1.164.1.2.4.1.1.13
Indicates the type of the port attachment. Smart attachment types are applicable for rr-sat card only
OBJECT-TYPE    
  INTEGER none(1), station(2), sLau2(3), sLau4(4)  

prtMMTable 1.3.6.1.4.1.164.1.2.4.2
RADRing specific WAN modules port information.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtMMEntry

prtMMEntry 1.3.6.1.4.1.164.1.2.4.2.1
An entry in table prtMMTable.
OBJECT-TYPE    
  PrtMMEntry  

prtMMmdlID 1.3.6.1.4.1.164.1.2.4.2.1.1
A unique identifier of the module(slot no.)this port is attached to.
OBJECT-TYPE    
  Integer32  

prtMMID 1.3.6.1.4.1.164.1.2.4.2.1.2
A unique identifier of the port (link) within its module.
OBJECT-TYPE    
  Integer32  

prtMMAdminCmd 1.3.6.1.4.1.164.1.2.4.2.1.3
Setting the object to locLoop(2) or remLoop(3) will activate the corresponding test. Value remLoop(3) activates the BERT test on the related link if mdlMMBertCmd is set to on(3). Setting parameter to normal(1), restores the normal operation of the link. The parameter is read-only when value of mdlRRMngState is disable
OBJECT-TYPE    
  INTEGER normal(1), locLoop(2), remLoop(3)  

prtMMOperStatus 1.3.6.1.4.1.164.1.2.4.2.1.4
Reflects the Synchronization status.
OBJECT-TYPE    
  INTEGER operational(1), locSyncLoss(2), remSyncLoss(3)  

prtMMTestStatus 1.3.6.1.4.1.164.1.2.4.2.1.5
Reflects the link status. When the object is set to the value of bert(4), it means that the remote loopback is active too.
OBJECT-TYPE    
  INTEGER normal(1), locLoop(2), remLoop(3), bert(4)  

prtMMBertResult 1.3.6.1.4.1.164.1.2.4.2.1.6
The value of this object indicates the status of the last BERT test.
OBJECT-TYPE    
  INTEGER unknown(1), fault(2), ok(3)  

prtMMTrapMaskEnable 1.3.6.1.4.1.164.1.2.4.2.1.7
When this object is set to OFF by the management console, the agent starts sending the unmasked traps related to this module. Otherwise, no traps are sent by this module.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtETTable 1.3.6.1.4.1.164.1.2.4.3
RADRing specific Ethernet port information
OBJECT-TYPE    
  SEQUENCE OF  
    PrtETEntry

prtETEntry 1.3.6.1.4.1.164.1.2.4.3.1
An entry in table prtETTable.
OBJECT-TYPE    
  PrtETEntry  

prtETmdlID 1.3.6.1.4.1.164.1.2.4.3.1.1
A unique identifier of the module, (slot no.), this port is attached to.
OBJECT-TYPE    
  Integer32  

prtETID 1.3.6.1.4.1.164.1.2.4.3.1.2
A unique identifier of the port within its module.
OBJECT-TYPE    
  Integer32  

prtETTrapMaskEnable 1.3.6.1.4.1.164.1.2.4.3.1.3
When this attribute is set to OFF by the management console, the agent starts sending the unmasked traps related to this port. Otherwise, no traps are sent by this port.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtRRSecTable 1.3.6.1.4.1.164.1.2.4.4
RR Port Security Table (10.08.95)
OBJECT-TYPE    
  SEQUENCE OF  
    PrtRRSecEntry

prtRRSecEntry 1.3.6.1.4.1.164.1.2.4.4.1
An entry in table prtRRSecTable.
OBJECT-TYPE    
  PrtRRSecEntry  

prtRRSecmdlID 1.3.6.1.4.1.164.1.2.4.4.1.1
A unique identifier of the module,(slot no.),this port is attached to.
OBJECT-TYPE    
  Integer32  

prtRRSecPrtID 1.3.6.1.4.1.164.1.2.4.4.1.2
A unique identifier of the port within its module.
OBJECT-TYPE    
  Integer32  

prtRRSecID 1.3.6.1.4.1.164.1.2.4.4.1.3
A unique identifier of the security number within the port.
OBJECT-TYPE    
  Integer32  

prtRRSecMask 1.3.6.1.4.1.164.1.2.4.4.1.4
Mask of the allowed MAC address that can be connected through this port. The security of the individual port overwrites the security of the segment, the port belongs to
OBJECT-TYPE    
  MacAddress  

prtRRSecPattern 1.3.6.1.4.1.164.1.2.4.4.1.5
A six-octet(48 bit) pattern, where the masked bits of prtRRSecMask should match the MAC address.
OBJECT-TYPE    
  MacAddress  

radFddi 1.3.6.1.4.1.164.2
OBJECT IDENTIFIER    

radFddiStation 1.3.6.1.4.1.164.2.1
OBJECT IDENTIFIER    

radFddiStationsNumber 1.3.6.1.4.1.164.2.1.1
The number of manageable Stations implemented in the box.
OBJECT-TYPE    
  Integer32 0..65535  

radFddiStationTable 1.3.6.1.4.1.164.2.1.2
A list of FddiStation entries. The number of entries is given by the value of radFddiStationsNumber.
OBJECT-TYPE    
  SEQUENCE OF  
    RadFddiStationEntry

radFddiStationEntry 1.3.6.1.4.1.164.2.1.2.1
An entry in table radFddiStationTable.
OBJECT-TYPE    
  RadFddiStationEntry  

radFddiStationIndex 1.3.6.1.4.1.164.2.1.2.1.1
A unique value for each Station. Its value ranges between 1 and the value ofradFddiStationNumber.
OBJECT-TYPE    
  Integer32 1..65535  

radFddiStationType 1.3.6.1.4.1.164.2.1.2.1.2
Indicates the type of the station.
OBJECT-TYPE    
  INTEGER other(1), singleAttachedStation(2), dualAttachedStation(3), singleAttachedConcentrator(4), dualAttachedConcentrator(5), nullAttachedConcentrator(6)  

radFddiStationBus1TestResult 1.3.6.1.4.1.164.2.1.2.1.3
Indicates the result of a test performed on Bus1.
OBJECT-TYPE    
  INTEGER ok(1), faulty(2)  

radFddiStationBus2TestResult 1.3.6.1.4.1.164.2.1.2.1.4
Indicates the result of a test performed on Bus2.
OBJECT-TYPE    
  INTEGER ok(1), faulty(2)  

radFddiStationTempDeInsertAction 1.3.6.1.4.1.164.2.1.2.1.5
This action provides temporary deinsertion of the root station from the ring. Expressed in milliseconds.
OBJECT-TYPE    
  INTEGER  

radFddiStationPerformTest 1.3.6.1.4.1.164.2.1.2.1.6
A value ON of this attribute indicates that a test should be performed upon the Station.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

radFddiStationOpticalSwitchStatus 1.3.6.1.4.1.164.2.1.2.1.7
A value ON of this attribute indicates that the Station is in bypass mode.
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

radFddiSMTTable 1.3.6.1.4.1.164.2.2
A list of FddiSMT entries. The number of entries is given by the value of snmpFddiSMTNumber.
OBJECT-TYPE    
  SEQUENCE OF  
    RadFddiSMTEntry

radFddiSMTEntry 1.3.6.1.4.1.164.2.2.1
An entry in table radFddiSMTTable.
OBJECT-TYPE    
  RadFddiSMTEntry  

radFddiSMTIndex 1.3.6.1.4.1.164.2.2.1.1
A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber.
OBJECT-TYPE    
  Integer32 1..65535  

radFddiSMTStation 1.3.6.1.4.1.164.2.2.1.2
Indicates the Station inside the box to which the current SMT belongs. Its value ranges between 1 and the value of radFddiStationNumber.
OBJECT-TYPE    
  Integer32 1..65535  

radFddiSMTCFState 1.3.6.1.4.1.164.2.2.1.3
The attachement configuration for the Station. Extends the range of values provided by the SNMP variable snmpFddiSMTCFState from the SNMP FDDI MIB.
OBJECT-TYPE    
  INTEGER isolated(1), localA(2), localB(3), localAB(4), localS(5), wrapA(6), wrapB(7), wrapAB(8), wrapS(9), cWrapA(10), cWrapB(11), cWrapS(12), thru(13)  

radFddiSMTLeftSlot 1.3.6.1.4.1.164.2.2.1.4
Indicates the slot number of the leftmost card on the concentrator implemented inside the box and managed by the agent MAC.
OBJECT-TYPE    
  Integer32  

radFddiSMTRightSlot 1.3.6.1.4.1.164.2.2.1.5
Indicates the slot number of the rightmost card on the concentrator implemented inside the box and managed by the agent MAC. Note that the MAC-agent card itself is not taken into consideration.
OBJECT-TYPE    
  Integer32  

radFddiMACTable 1.3.6.1.4.1.164.2.3
A list of FddiMAC entries. The number of entries is given by the value of snmpFddiMACNumber.
OBJECT-TYPE    
  SEQUENCE OF  
    RadFddiMACEntry

radFddiMACEntry 1.3.6.1.4.1.164.2.3.1
An entry in table radFddiMACTable.
OBJECT-TYPE    
  RadFddiMACEntry  

radFddiMACSMTIndex 1.3.6.1.4.1.164.2.3.1.1
The value of the SMT index associated with this MAC.
OBJECT-TYPE    
  Integer32 1..65535  

radFddiMACIndex 1.3.6.1.4.1.164.2.3.1.2
A unique value for each MAC. Its value ranges between 1 and the value of snmpFddiMACNumber.
OBJECT-TYPE    
  Integer32 1..65535  

radFddiMACStation 1.3.6.1.4.1.164.2.3.1.3
Indicates the Station inside the box to which the current MAC belongs. Its value ranges between 1 and the value of radFddiStationNumber.
OBJECT-TYPE    
  Integer32 1..65535  

radFddiMACTestResult 1.3.6.1.4.1.164.2.3.1.4
Indicates the result of a test performed on MAC. The value is a sum. It takes the value 0 if the result of the test is OK and if faults occur, 2 raised to a power is added to the sum. The powers are according to the following table: Fault Power cardConfigError 0 GeneralError 1 MACError 2
OBJECT-TYPE    
  Integer32  

radFddiMACTokenCt 1.3.6.1.4.1.164.2.3.1.5
Token Counts - Refer to ANSI MAC {73}.
OBJECT-TYPE    
  Counter32  

radFddiMACRingLoad 1.3.6.1.4.1.164.2.3.1.6
Current traffic value. The traffic is expressed in percents of the maximum FDDI traffic in the range 1..20, expressed on a log(10) scale ( value = 10*log10(percent) ).
OBJECT-TYPE    
  Integer32  

radFddiMACRingLoadBuffer 1.3.6.1.4.1.164.2.3.1.7
Record of traffic for the last second with a resolution of 100 msec. The traffic is expressed in percents of the maximum FDDI traffic and each record contains 10 readings, in the range 1..20, expressed on a log(10) scale ( value = 10*log10(percent) ).
OBJECT-TYPE    
  OCTET STRING  

radFddiMACRingLoadTrsh 1.3.6.1.4.1.164.2.3.1.8
Traffic threshold value. When exceeded, a trap is send to the management console. Expressed in percents of the maximum FDDI traffic, in the range 1..20, expressed on a log(10) scale.
OBJECT-TYPE    
  Integer32  

radFddiMACRingLoadPeak 1.3.6.1.4.1.164.2.3.1.9
Maximal traffic value since last reset of hub or relay. Expressed in per- cents of the maximum FDDI traffic, in the range 1..20, expressed on log(10) scale.
OBJECT-TYPE    
  Integer32  

radFddiMACDownstreamNbr 1.3.6.1.4.1.164.2.3.1.10
The MAC's downstream neighbor's long individual MAC address. The value shall be reported as '00 00 00 00 00 00' if it is unknown.
OBJECT-TYPE    
  OCTET STRING SIZE(6)  

radFddiMACRingStatus 1.3.6.1.4.1.164.2.3.1.11
Attribute which summs the status of the ring controlled by the current MAC.
OBJECT-TYPE    
  INTEGER ringUp(1), ringDown(2)  

radFddiMACRingUtilization 1.3.6.1.4.1.164.2.3.1.12
Current traffic value. The traffic is expressed in percents of the maximum FDDI traffic.
OBJECT-TYPE    
  Integer32  

radFddiMACRingPeakUtilization 1.3.6.1.4.1.164.2.3.1.13
Peak traffic value since las reset of the hub or relay. The traffic is expressed in percents of the maximum FDDI traffic.
OBJECT-TYPE    
  Integer32  

radFddiGroupTable 1.3.6.1.4.1.164.2.4
A list of FddiGroup entries. The number of entries is given by the value of snmpFddiGroupNumber.
OBJECT-TYPE    
  SEQUENCE OF  
    RadFddiGroupEntry

radFddiGroupEntry 1.3.6.1.4.1.164.2.4.1
An entry in table radFddiGroupTable.
OBJECT-TYPE    
  RadFddiGroupEntry  

radFddiGroupId 1.3.6.1.4.1.164.2.4.1.1
Unique ID of the group in radFddiGroupTable. Equivalent to slot number in enclosures.
OBJECT-TYPE    
  Integer32  

radFddiGroupRedundancy 1.3.6.1.4.1.164.2.4.1.2
This attribute shows the usage of the A/B pair of ports in Tree mode. If the redundancy conditions are not fulfilled, value none(1) will be returned. If backup mode port A is a standby backup of port B, otherwise each of them is connected to a separate bus.
OBJECT-TYPE    
  INTEGER none(1), double-bandwidth(2), backup(3)  

radFddiGroupTopologyMode 1.3.6.1.4.1.164.2.4.1.3
Defines the topology mode of the FDDI PHY card.
OBJECT-TYPE    
  INTEGER none(1), tree(2), ring(3)  

radFddiGroupTestResult 1.3.6.1.4.1.164.2.4.1.4
Result of test performed upon an FDDI group. A value of faulty (1) indicates a CPU or communication at module level.
OBJECT-TYPE    
  INTEGER ok(1), faulty(2)  

radFddiGroupConfigStatus 1.3.6.1.4.1.164.2.4.1.5
Indicates the configuration status of the module (group).
OBJECT-TYPE    
  INTEGER ok(1), cardConfigErrorAB(2), cardConfigErrorS(3), switchTopologyError(4)  

radFddiGroupAutoRightLoop 1.3.6.1.4.1.164.2.4.1.6
Value ON of this attribute signifies that a hardware loop was automatically created on a FDDI module which does not sense the existence of another FDDI group on the right hand side.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

radFddiGroupAutoLeftLoop 1.3.6.1.4.1.164.2.4.1.7
Value ON of this attribute signifies that a hardware loop was automatically created on a FDDI module which does not sense the existence of another FDDI group on the left hand side.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

radFddiGroupManRightLoop 1.3.6.1.4.1.164.2.4.1.8
Setting this attribute to ON signifies a command to the hardware to create a loop on the FDDI module which isolates the ring from the right hand side.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

radFddiGroupManLeftLoop 1.3.6.1.4.1.164.2.4.1.9
Setting this attribute to ON signifies a command to the hardware to create a loop on the FDDI module which isolates the ring from the left hand side.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

radFddiGroupOpticalSwitchStatus 1.3.6.1.4.1.164.2.4.1.10
This attribute describes the presence of the optical switch and for existing optical switches describes the possibility of auto-reconfiguration of path resources (MACs and M-ports) in the case of bus fault or connection disabling. If merge(2), resources will try to move to another bus, if non-merge(1) resources are left on their dedicated bus.
OBJECT-TYPE    
  INTEGER not-present(1), inserted(2), not-inserted(3), present(4)  

radFddiPortTable 1.3.6.1.4.1.164.2.5
.
OBJECT-TYPE    
  SEQUENCE OF  
    RadFddiPortEntry

radFddiPortEntry 1.3.6.1.4.1.164.2.5.1
An entry in table radFddiPortTable.
OBJECT-TYPE    
  RadFddiPortEntry  

radFddiPortGroupID 1.3.6.1.4.1.164.2.5.1.1
ID of group to which the FDDI card belongs.
OBJECT-TYPE    
  Integer32  

radFddiPortID 1.3.6.1.4.1.164.2.5.1.2
Unique Id of the port in the radFddiPortEntry.
OBJECT-TYPE    
  Integer32  

radFddiPortTestResult 1.3.6.1.4.1.164.2.5.1.4
Indicates the result of a test performed on a port.
OBJECT-TYPE    
  INTEGER ok(1), faulty(2)  

radFddiPortNumberOfConnectedStations 1.3.6.1.4.1.164.2.5.1.5
Number of stations connected to the port.
OBJECT-TYPE    
  Integer32  

radFddiPortConnectedStations 1.3.6.1.4.1.164.2.5.1.6
This attribute displays the configuration of the stations connected to the port.The FDDI addresses of the stations are displayed in ring order, starting with the address of the first station connected to the port. The length of the string is equal to the value of radFddiPortNumberOfConnectedStations multiplied by 8 (length of FddiSMTStationIdType).
OBJECT-TYPE    
  OCTET STRING  

radFddiPortCurrentPath 1.3.6.1.4.1.164.2.5.1.8
Current Path in FDDI port on PHY cards.
OBJECT-TYPE    
  INTEGER isolated(1), local(2), secondary(3), primary(4), concatenated(5), thru(6)  

radFddiPortFunctionalStatus 1.3.6.1.4.1.164.2.5.1.9
Fubctional status of the port according to value of link error estimate relative to thresholds of alarm and cutoff.
OBJECT-TYPE    
  INTEGER ok(1), lerAlarm(2), lerCutoff(3)  

radFddiAgn 1.3.6.1.4.1.164.2.6
OBJECT IDENTIFIER    

radFddiAgnPriSwDesc 1.3.6.1.4.1.164.2.6.1
ASCII string for description and display of the Fddi agent software version.
OBJECT-TYPE    
  DisplayString  

radWan 1.3.6.1.4.1.164.3
OBJECT IDENTIFIER    

wanGen 1.3.6.1.4.1.164.3.1
OBJECT IDENTIFIER    

chasWanGen 1.3.6.1.4.1.164.3.1.1
OBJECT IDENTIFIER    

chasVersion 1.3.6.1.4.1.164.3.1.1.1
An ASCII string for description and display of the agent chassis version.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

chasTotalNoOfSlt 1.3.6.1.4.1.164.3.1.1.2
This entry indicates the number of physical slots in the chassis.
OBJECT-TYPE    
  Integer32  

chasTotalNoOfIoSlt 1.3.6.1.4.1.164.3.1.1.3
This entry indicates the total number of physical IO slots in the chassis, (not all slots hardware should be occupied and active) .
OBJECT-TYPE    
  Integer32  

chasTotalNoOfPsSlt 1.3.6.1.4.1.164.3.1.1.4
This entry indicates the number of physical Power Supply slots in the chassis.
OBJECT-TYPE    
  Integer32  

chasTotalNoOfClSlt 1.3.6.1.4.1.164.3.1.1.5
This entry indicates the number of physical Common Logic slots in the chassis.
OBJECT-TYPE    
  Integer32  

agnWanGen 1.3.6.1.4.1.164.3.1.2
OBJECT IDENTIFIER    

statAgnGen 1.3.6.1.4.1.164.3.1.2.1
OBJECT IDENTIFIER    

agnSDateFormat 1.3.6.1.4.1.164.3.1.2.1.1
This entry indicates the date and time format used for the agnSDateAndTimeCmd and for the alarm history report.
OBJECT-TYPE    
  INTEGER ddMMYYYY(1), mmDDYYYY(2), yyyyDDMM(3), yyyyMMDD(4)  

agnSDateCmd 1.3.6.1.4.1.164.3.1.2.1.2
This entry indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

agnSTimeCmd 1.3.6.1.4.1.164.3.1.2.1.3
This entry indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

agnSActiveCnfg 1.3.6.1.4.1.164.3.1.2.1.4
This entry specifies the unique identifier of the configuration, that is currently active and running.
OBJECT-TYPE    
  Integer32  

agnSEditCnfg 1.3.6.1.4.1.164.3.1.2.1.5
This entry indicates the unique identifier of the configuration that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process.
OBJECT-TYPE    
  Integer32  

agnSLastCnfgFlipTime 1.3.6.1.4.1.164.3.1.2.1.6
This entry indicates the Date & Time of the last flip to the current configuration at the agent.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

agnSLastCnfgFlipCause 1.3.6.1.4.1.164.3.1.2.1.7
This entry describes the flip's cause.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

agnSEditBy 1.3.6.1.4.1.164.3.1.2.1.8
This entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after an update(load) operation.
OBJECT-TYPE    
  INTEGER none(1), snmp(2), terCon1(3), terCon2(4), terInbandCon1(5), terInbandCon2(6), lcd(7)  

agnSClkSrc 1.3.6.1.4.1.164.3.1.2.1.9
This entry indicates the source of the system clock.
OBJECT-TYPE    
  INTEGER master(1), fallback(2), internal(3)  

agnSAlrStatus 1.3.6.1.4.1.164.3.1.2.1.10
Indicates the alarm state in the agent level, i.e. lower level (card/port) alarms not included. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSAlrStatusAll 1.3.6.1.4.1.164.3.1.2.1.11
Indicates the alarm state of the entire agent, i.e. including card and port alarms status. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSMaskedAlrStat 1.3.6.1.4.1.164.3.1.2.1.12
Indicates the alarm state in the agent level,[ i.e. lower level (card/port) alarms not included] including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSMaskedAlrStatAll 1.3.6.1.4.1.164.3.1.2.1.13
Indicates the alarm state of the entire agent, i.e. including card and port alarms status,including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSTstStatAll 1.3.6.1.4.1.164.3.1.2.1.14
on(3) - when there is at least one test in progress in one of the agent cards, otherwise the value will be off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSAlrTable 1.3.6.1.4.1.164.3.1.2.1.15
List of agent related alarms and indications for alarms at system level.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSAlrEntry

agnSAlrEntry 1.3.6.1.4.1.164.3.1.2.1.15.1
An entry in table.
OBJECT-TYPE    
  AgnSAlrEntry  

agnSAlrIdx 1.3.6.1.4.1.164.3.1.2.1.15.1.1
A unique number to identify an entry in the alarm status table of the agent.
OBJECT-TYPE    
  Integer32  

agnSAlrCodeDescription 1.3.6.1.4.1.164.3.1.2.1.15.1.2
This attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

agnSAlrCode 1.3.6.1.4.1.164.3.1.2.1.15.1.3
A code identifying the alarm of an entry in the alarm status table at system level.
OBJECT-TYPE    
  Integer32  

agnSAlrSeverity 1.3.6.1.4.1.164.3.1.2.1.15.1.4
The severity of the alarm.
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

agnSAlrState 1.3.6.1.4.1.164.3.1.2.1.15.1.5
State of the alarm.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSAlrCounter 1.3.6.1.4.1.164.3.1.2.1.15.1.6
A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
OBJECT-TYPE    
  Integer32  

agnSAlrMask 1.3.6.1.4.1.164.3.1.2.1.15.1.7
Alarm mask : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSAlrInvert 1.3.6.1.4.1.164.3.1.2.1.15.1.8
Alarm invert : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSClearAlrCmd 1.3.6.1.4.1.164.3.1.2.1.16
Setting this attribute to ON, enforce a clear operation on all the agent(general) events. General alarms are alarms which are not specific to a card or port. The clear operation will not be applied for masked/inverted alarms.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSClearAllAlrCmd 1.3.6.1.4.1.164.3.1.2.1.17
Setting this attribute to ON, enforce a clear operation on all MUX alarm events at the levels of agent, slots and ports. The clear operation will not be applied for masked/inverted alarms.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSSanityCheckStatus 1.3.6.1.4.1.164.3.1.2.1.18
Upon completion of the Sanity check process on the TmpCnfg this attribute will be set to: FAIL(2) - when there is at least one error encountered and possibly some warnings. WARNING(3) - when there are only warnings. otherwise, the value will be OK(4). The value will be UNKNOWN(1) if changes were made in the TmpCnfg following the last Sanity check.
OBJECT-TYPE    
  INTEGER unknown(1), fail(2), warning(3), ok(4)  

agnSNoOfSanityCheckErr 1.3.6.1.4.1.164.3.1.2.1.19
This entry indicates the number of errors/warnings discovered by the last SanityCheck process.
OBJECT-TYPE    
  Integer32  

agnSErrListTable 1.3.6.1.4.1.164.3.1.2.1.20
List of errors and warnings found during Sanity Check process.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSErrListEntry

agnSErrListEntry 1.3.6.1.4.1.164.3.1.2.1.20.1
An entry in table.
OBJECT-TYPE    
  AgnSErrListEntry  

agnSErrIdx 1.3.6.1.4.1.164.3.1.2.1.20.1.1
Unique number to identify an entry in the error list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'.
OBJECT-TYPE    
  Integer32  

agnSErrDescription 1.3.6.1.4.1.164.3.1.2.1.20.1.2
This attribute is a full text description of the sanity check error including error code, slot and port numbers related to the code .
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

agnSMaxNoOfCnfg 1.3.6.1.4.1.164.3.1.2.1.21
Maximum number of configurations that can be defined and stored in the MUX. If the mux has a large capacity, the maximum will be limited to 254.
OBJECT-TYPE    
  Integer32  

agnSCnfgTable 1.3.6.1.4.1.164.3.1.2.1.22
This table contains an entry per configuration. It indicates if the configuration is valid.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSCnfgEntry

agnSCnfgEntry 1.3.6.1.4.1.164.3.1.2.1.22.1
An entry in table.
OBJECT-TYPE    
  AgnSCnfgEntry  

agnSEntryIdx 1.3.6.1.4.1.164.3.1.2.1.22.1.1
Unique number to identify an entry in the configuration table.
OBJECT-TYPE    
  Integer32  

agnSEntryIsValid 1.3.6.1.4.1.164.3.1.2.1.22.1.2
This attribute indicates whether the specific configuration is valid in the MUX . Value of NO indicates: no such configuration in the MUX.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

cnfgAgnGen 1.3.6.1.4.1.164.3.1.2.2
OBJECT IDENTIFIER    

agnCSanityCheckCmd 1.3.6.1.4.1.164.3.1.2.2.1
Setting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion the value will automatically be changed to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCSaveCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.2
This attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown
OBJECT-TYPE    
  Integer32 1..100  

agnCLoadCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.3
This attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on Valid configurations (agnSEntryIsValid)
OBJECT-TYPE    
  Integer32 1..100  

agnCClkSrcTable 1.3.6.1.4.1.164.3.1.2.2.4
All the entries of this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCClkSrcEntry

agnCClkSrcEntry 1.3.6.1.4.1.164.3.1.2.2.4.1
An entry in table.
OBJECT-TYPE    
  AgnCClkSrcEntry  

agnCClkCnfgIdx 1.3.6.1.4.1.164.3.1.2.2.4.1.1
This attribute indicates the Idx of the Cnfg(1..100) being accessed and Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

agnCClkSrcIdx 1.3.6.1.4.1.164.3.1.2.2.4.1.2
An index to the table. There are only two entries to this table. Index 1 points to the Master clock parameters and Index 2 points to the Fallback clock parameters
OBJECT-TYPE    
  Integer32 1..2  

agnCClkSrcMode 1.3.6.1.4.1.164.3.1.2.2.4.1.3
The source of the nodal timing.
OBJECT-TYPE    
  INTEGER internal(1), rxClk(2), adaptive(3)  

agnCClkSrcSlt 1.3.6.1.4.1.164.3.1.2.2.4.1.4
This entry is valid only when we are working in rxClk mode. For an invalid entry, the return value will be '7fff'h.
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

agnCClkSrcPrt 1.3.6.1.4.1.164.3.1.2.2.4.1.5
This entry is valid only when we are working in rxClk or adaptive mode. For an invalid entry, the return value will be '7fff'h. - For rxClk mode, the values can be: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , notApplicable (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) - For adaptive mode, the value will be the ifIndex of the selected IP Bundle.
OBJECT-TYPE    
  Integer32  

agnCDeleteCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.5
Setting this attribute will delete the requested DB from the NVRAM .
OBJECT-TYPE    
  Integer32 1..100  

agnCDefaultCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.6
Setting this attribute will define the desired working configuration when no conditions of the Flip DB Table are fulfilled and no Net GO command was issued. This command will be accepted only if the Configuration number exists (agnSEntryIsValid=yes).
OBJECT-TYPE    
  Integer32 1..100  

agnCnfgDataTable 1.3.6.1.4.1.164.3.1.2.2.7
This table contains data about the agent configurations. The table will support only data about valid configurations of the agent.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCnfgDataEntry

agnCnfgDataEntry 1.3.6.1.4.1.164.3.1.2.2.7.1
An entry in table.
OBJECT-TYPE    
  AgnCnfgDataEntry  

agnCnfgIdx 1.3.6.1.4.1.164.3.1.2.2.7.1.1
This object indicates the Idx of the agent' Cnfg the following objects refer. 255=Temporary Cnfg (Set is done only to this configuration).
OBJECT-TYPE    
  Integer32 1..255  

agnCnfgDesc 1.3.6.1.4.1.164.3.1.2.2.7.1.2
This object is a description of the Configuration, entered by user, to enhance Cnfg recognition.
OBJECT-TYPE    
  DisplayString SIZE(0..30)  

agnCnfgUpdDate 1.3.6.1.4.1.164.3.1.2.2.7.1.3
This object indicates the date when last update of this configuration was performed, as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. When update is performed, the agent should save the date.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

agnCnfgUpdTime 1.3.6.1.4.1.164.3.1.2.2.7.1.4
This object indicates the time when last update of this configuration was performed, as it is known by the agent using its own real-time clock. When update is performed, the agent should save the time.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

agnCnfgUpdMnger 1.3.6.1.4.1.164.3.1.2.2.7.1.5
This object indicates the IP Address of the Manager who performed the last update of this configuration. When update is performed, the agent should save the IP Address of the Manager who commanded the update. That will enable a manager to know if he performed the last update, or another manager did.
OBJECT-TYPE    
  IpAddress  

agnCnfgAlarm 1.3.6.1.4.1.164.3.1.2.2.8
OBJECT IDENTIFIER    

agnCnfgAlrFilterWindow 1.3.6.1.4.1.164.3.1.2.2.8.1
Window of time, in seconds. During this Window, the alarms filter is performed. Same Window for all agent alarms that need filtering. Upon end of the Window, the state of the alarm is updated and a new Window starts. If no alarm needs filtering, this object's value will not be used.
OBJECT-TYPE    
  Integer32 0..255  

agnCnfgAlrTable 1.3.6.1.4.1.164.3.1.2.2.8.2
This table enables the user to set attributes to each alarm. Setting for a non-existing entry agnCnfgAlrMask, agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave for Mask) will add this new entry to the table. Setting for an existing entry agnCnfgAlrMask/ agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no' (noAndSave for Mask) so that ALL these objects' values are 'no' , will delete this entry from the table. For agnCnfgAlrMask, only if [(last saved value=noAndSave) AND (new value is 'no' or 'noAndSave')] the object's value is considered 'no' for deleting the entry. For some products (like MP, MPH, Vmux2100) the Active Alarms are always part of the table and cannot be removed even if their Mask/Invert/Filter are No.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCnfgAlrEntry

agnCnfgAlrEntry 1.3.6.1.4.1.164.3.1.2.2.8.2.1
An entry in table.
OBJECT-TYPE    
  AgnCnfgAlrEntry  

agnCnfgAlrCode 1.3.6.1.4.1.164.3.1.2.2.8.2.1.1
The alarm code. The following attributes refer this code.
OBJECT-TYPE    
  Integer32  

agnCnfgAlrSlot 1.3.6.1.4.1.164.3.1.2.2.8.2.1.2
The alarm slot. The following attributes apply for the alarm code and slot selected. all = the attributes apply to all slots. notApplicable = the selected alarm is for system level. For the Vmux2100 Main Board clA (3) is used.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), all(200), notApplicable(255)  

agnCnfgAlrPort 1.3.6.1.4.1.164.3.1.2.2.8.2.1.3
The alarm port. The following attributes apply for the alarm code,slot and port selected. 200 = all = the attributes apply to all ports of the selected slot. When selected Slot is 'all', only 'all' or 'notApplicable' are valid Port selections. notApplicable = the selected alarm is for system or card level. =255 for MP =100 for DXC - For MP: - valid cards' ports are: exPrt1(1)..exPrt16(16) inPrt1(101)..inPrt48 (148) - IP Bundles - For DXC, the port index will include the Slot, as for all DXC tables: [(IO Slot+10)&n] ; n=odd for external ports n=even for internal ports.
OBJECT-TYPE    
  Integer32  

agnCnfgAlrMask 1.3.6.1.4.1.164.3.1.2.2.8.2.1.4
An attribute defining the desired Mask state of an alarm . no - unmask (this command is not saved in agent's common database) noAndSave - unmask ; this command is saved in agent's common database yes - mask (this command is not saved in agent's common database) yesAndSave - mask ; this command is saved in agent's common database. Commands that are not saved, will be lost upon power-up or selected card removal.
OBJECT-TYPE    
  INTEGER no(1), noAndSave(2), yes(3), yesAndSave(4)  

agnCnfgAlrInvert 1.3.6.1.4.1.164.3.1.2.2.8.2.1.5
An attribute defining the desired Invert state of an alarm . no - not inverted. yes - inverted. For MP, it is not applicable for alarms that are currently OFF.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCnfgAlrFilter 1.3.6.1.4.1.164.3.1.2.2.8.2.1.6
An attribute defining if Filter is desired for the alarm . no - no filter. yes - filter activate. This filter is activated within a window of time defined by agnCnfgAlrFilterWindow. Its purpose is to avoid frequent changes of an alarm between ON/OFF states.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCnfgAlrFilterSet 1.3.6.1.4.1.164.3.1.2.2.8.2.1.7
This is a top threshold causing the alarm that passes it, to be declared Set (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at least, during the window in order to be considered ON. The maximum value will be 255. This value should be greater than the one of agnCnfgAlrFilterReset. Agents that do not support Alarms Filter, will return 0.
OBJECT-TYPE    
  Integer32  

agnCnfgAlrFilterReset 1.3.6.1.4.1.164.3.1.2.2.8.2.1.8
This is a bottom threshold causing the alarm that does not pass it, to be declared Reset (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at most, during the window, in order to be considered OFF. This value should be less than the one of agnCnfgAlrFilterSet. Agents that do not support Alarms Filter, will return 0.
OBJECT-TYPE    
  Integer32  

agnCnfgAlrReportTable 1.3.6.1.4.1.164.3.1.2.2.8.3
This table enables the user to configure the desired Alarm Reports according to alarms severity.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCnfgAlrReportEntry

agnCnfgAlrReportEntry 1.3.6.1.4.1.164.3.1.2.2.8.3.1
An entry in table.
OBJECT-TYPE    
  AgnCnfgAlrReportEntry  

agnCnfgAlrReportType 1.3.6.1.4.1.164.3.1.2.2.8.3.1.1
The alarm report type. trap - traps will be sent only for alarms having the selected On/Off severity or higher. buffer - only alarms having the selected On/Off severity and higher, will be reported to the buffer. relay - relay contact will be activated only for alarms having the selected On severity or higher. For products having 2 relays, this is the R1 Relay. alrLedOn/alrLedBlink - user should select a higher severity (ReportOn) for alrLedBlink than for alrLedOn (Blinking Led means a more severe alarm than steady ON Led). alrLedOn - MTCL-1 Alarm Led will be ON only when agnSAlrStatusAll equals the selected severity or higher, but lower severity than that selected for 'alrLedBlink'. For products having 2 LEDs, this is the Minor LED. alrLedBlink - MTCL-1 Alarm Led will Blink only when agnSAlrStatusAll equals the selected severity or higher. For products having 2 LEDs, this is the Major LED. relay2 - relay 2 contact will be activated only for alarms having the selected On severity or higher. This is the R2 Relay.
OBJECT-TYPE    
  INTEGER trap(1), buffer(2), relay(3), alrLedOn(4), alrLedBlink(5), relay2(6)  

agnCnfgAlrStartReportOn 1.3.6.1.4.1.164.3.1.2.2.8.3.1.2
This object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to ON state. noReport - no Report at all (for any severity).
OBJECT-TYPE    
  INTEGER noReport(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnCnfgAlrStartReportOff 1.3.6.1.4.1.164.3.1.2.2.8.3.1.3
This object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to OFF state. notApplicable - for 'relay','alrLedOn','alrLedBlink', 'relay2' report types, in MP. noReport - no Report at all (for any severity).
OBJECT-TYPE    
  INTEGER notApplicable(1), noReport(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnCOffsetCmd 1.3.6.1.4.1.164.3.1.2.2.9
An object defining special user request. notApplicable - is RO value for products that do not support this object. normal - nothing special u1 - user 1 - for all Voice cards, the DISPLAYED Tx and Rx Levels will have the following Offsets: - 2 Wires port: Tx Level: the base value (for 0dBm) = 0 Rx Level: the base value (for 0dBm) = -2 - 4 Wires port: Tx Level: the base value (for 0dBm) = -16 Rx Level: the base value (for 0dBm) = 7 The MIB and application DB will use the values without Offset.
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), u1(3)  

agnCT1E1RingTable 1.3.6.1.4.1.164.3.1.2.2.10
Configuration of all T1/E1 Ring ML cards and ports. The write operation into the table objects is valid only for the TmpCnfg. A Slot/Port that does not participate in the T1/E1 Ring, will not exist in this table. A ML port that exists in this table, cannot exist at the same time in the IO Redundancy table (sysCRdnTable).
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCT1E1RingEntry

agnCT1E1RingEntry 1.3.6.1.4.1.164.3.1.2.2.10.1
An Entry in table agnCT1E1RingTable
OBJECT-TYPE    
  AgnCT1E1RingEntry  

agnCT1E1RingCnfgIdx 1.3.6.1.4.1.164.3.1.2.2.10.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32  

agnCT1E1RingPrimeSlot 1.3.6.1.4.1.164.3.1.2.2.10.1.2
The slot number of the Primary card of the Ring Pair.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnCT1E1RingPrimePort 1.3.6.1.4.1.164.3.1.2.2.10.1.3
The port number in the Primary Card. For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104
OBJECT-TYPE    
  Integer32  

agnCT1E1RingSecSlot 1.3.6.1.4.1.164.3.1.2.2.10.1.4
The slot number of the Secondary card of the Ring Pair.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnCT1E1RingSecPort 1.3.6.1.4.1.164.3.1.2.2.10.1.5
The port number in the Secondary Card. For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104
OBJECT-TYPE    
  Integer32  

agnCT1E1RingRecTime 1.3.6.1.4.1.164.3.1.2.2.10.1.6
T1/E1 Ring Recovery Time (sec).
OBJECT-TYPE    
  Integer32 1..99  

agnCT1E1RingRowStatus 1.3.6.1.4.1.164.3.1.2.2.10.1.7
This parameter allows NMS to create/delete entries of this table. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

cmprAgnGen 1.3.6.1.4.1.164.3.1.2.3
OBJECT IDENTIFIER    

agnCmprTable 1.3.6.1.4.1.164.3.1.2.3.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCmprEntry

agnCmprEntry 1.3.6.1.4.1.164.3.1.2.3.1.1
An entry in table.
OBJECT-TYPE    
  AgnCmprEntry  

agnCmprTypIdx 1.3.6.1.4.1.164.3.1.2.3.1.1.1
This attribute indicates the Type of the Compressed being referred.
OBJECT-TYPE    
  Integer32  

agnCmprCnfgIdx 1.3.6.1.4.1.164.3.1.2.3.1.1.2
This attribute indicates the configuration to which the Compressed information is related.
OBJECT-TYPE    
  Integer32  

agnCmprVersion 1.3.6.1.4.1.164.3.1.2.3.1.1.3
This attribute indicates the version of the internal format of the Compressed data
OBJECT-TYPE    
  Integer32  

agnCmprObj 1.3.6.1.4.1.164.3.1.2.3.1.1.4
This attribute is the compressed information itself.
OBJECT-TYPE    
  OCTET STRING  

agnDlciCmprTable 1.3.6.1.4.1.164.3.1.2.3.2
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnDlciCmprEntry

agnDlciCmprEntry 1.3.6.1.4.1.164.3.1.2.3.2.1
An entry in table.
OBJECT-TYPE    
  AgnDlciCmprEntry  

agnDlciCmprCnfgIdx 1.3.6.1.4.1.164.3.1.2.3.2.1.1
This attribute indicates the configuration to which the Compressed information is related.
OBJECT-TYPE    
  Integer32  

agnDlciCmprVersion 1.3.6.1.4.1.164.3.1.2.3.2.1.2
This attribute indicates the version of the internal format of the Compressed data
OBJECT-TYPE    
  Integer32  

agnDlciCmprDlciIdx 1.3.6.1.4.1.164.3.1.2.3.2.1.3
This attribute indicates a unique identifier of the Dlci, the compressed information relates to. The values are between 16 - 991.
OBJECT-TYPE    
  Integer32  

agnDlciCmprObj 1.3.6.1.4.1.164.3.1.2.3.2.1.4
This attribute is the compressed information itself.
OBJECT-TYPE    
  OCTET STRING  

agnAlarmsCmprTable 1.3.6.1.4.1.164.3.1.2.3.3
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnAlarmsCmprEntry

agnAlarmsCmprEntry 1.3.6.1.4.1.164.3.1.2.3.3.1
An entry in table.
OBJECT-TYPE    
  AgnAlarmsCmprEntry  

agnAlarmsCmprVersion 1.3.6.1.4.1.164.3.1.2.3.3.1.1
This attribute indicates the version of the internal format of the Compressed data
OBJECT-TYPE    
  Integer32  

agnAlarmsCmprAlarmIdx 1.3.6.1.4.1.164.3.1.2.3.3.1.2
A unique number to identify an entry in the alarm status table of the agent.
OBJECT-TYPE    
  Integer32  

agnAlarmsCmprObj 1.3.6.1.4.1.164.3.1.2.3.3.1.3
This attribute is the compressed information itself.
OBJECT-TYPE    
  OCTET STRING  

agnAlrBufCmprTable 1.3.6.1.4.1.164.3.1.2.3.4
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnAlrBufCmprEntry

agnAlrBufCmprEntry 1.3.6.1.4.1.164.3.1.2.3.4.1
An entry in table.
OBJECT-TYPE    
  AgnAlrBufCmprEntry  

agnAlrBufCmprVersion 1.3.6.1.4.1.164.3.1.2.3.4.1.1
This attribute indicates the version of the internal format of the Compressed data
OBJECT-TYPE    
  Integer32  

agnAlrBufCmprAlarmIdx 1.3.6.1.4.1.164.3.1.2.3.4.1.2
A unique number to identify an entry in the history alarms buffer of the agent.
OBJECT-TYPE    
  Integer32  

agnAlrBufCmprObj 1.3.6.1.4.1.164.3.1.2.3.4.1.3
This attribute is the compressed information itself.
OBJECT-TYPE    
  OCTET STRING  

agnSCmprErrListTable 1.3.6.1.4.1.164.3.1.2.3.5
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSCmprErrListEntry

agnSCmprErrListEntry 1.3.6.1.4.1.164.3.1.2.3.5.1
An entry in table.
OBJECT-TYPE    
  AgnSCmprErrListEntry  

agnSCmprErrVersion 1.3.6.1.4.1.164.3.1.2.3.5.1.1
The version of the compressed data
OBJECT-TYPE    
  Integer32  

agnSCmprErrIdx 1.3.6.1.4.1.164.3.1.2.3.5.1.2
Unique number to identify an entry in the errors list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'.
OBJECT-TYPE    
  Integer32  

agnSCmprErrObj 1.3.6.1.4.1.164.3.1.2.3.5.1.3
This attribute is a full text description of the error, including: error code, slot and port numbers related to the code .
OBJECT-TYPE    
  OCTET STRING  

agnTsCmprTable 1.3.6.1.4.1.164.3.1.2.3.6
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnTsCmprEntry

agnTsCmprEntry 1.3.6.1.4.1.164.3.1.2.3.6.1
An entry in table.
OBJECT-TYPE    
  AgnTsCmprEntry  

agnTsCmprVerIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.1
This object indicates the version of the internal format of the Compressed data.
OBJECT-TYPE    
  Integer32  

agnTsCmprCnfgIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.2
This object indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration.
OBJECT-TYPE    
  Integer32  

agnTsCmprSlotIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.3
This object indicates the Slot to which the Compressed information is related. For MP-2100: IO-1..IO-12 = (5).. (16) For DXC-30 : IO-1..IO-15 = (5).. (19).
OBJECT-TYPE    
  Integer32  

agnTsCmprPortIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.4
This object indicates the Port within the Slot, to which the Compressed information is related. For Port Index see each product's spec.
OBJECT-TYPE    
  Integer32  

agnTsCmprPduIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.5
This object indicates the PDU index within the same port. That provides for the case when one PDU is not sufficient for all TS Assignment data of the same port.
OBJECT-TYPE    
  Integer32  

agnTsCmprData 1.3.6.1.4.1.164.3.1.2.3.6.1.6
This object is the compressed information itself. It provides information about all TSs of a port.
OBJECT-TYPE    
  OCTET STRING  

agnXCmprTable 1.3.6.1.4.1.164.3.1.2.3.7
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnXCmprEntry

agnXCmprEntry 1.3.6.1.4.1.164.3.1.2.3.7.1
An entry in table.
OBJECT-TYPE    
  AgnXCmprEntry  

agnXCmprTypIdx 1.3.6.1.4.1.164.3.1.2.3.7.1.1
This attribute indicates the Type of the Compressed being referred. One of the types is V5.1 Variant data.
OBJECT-TYPE    
  Integer32  

agnXCmprVersion 1.3.6.1.4.1.164.3.1.2.3.7.1.2
This attribute indicates the version of the internal format of the Compressed data.
OBJECT-TYPE    
  Integer32  

agnXCmprIdx3 1.3.6.1.4.1.164.3.1.2.3.7.1.3
3rd index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant, this attribute indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration.
OBJECT-TYPE    
  Integer32  

agnXCmprIdx4 1.3.6.1.4.1.164.3.1.2.3.7.1.4
4th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique number of the slot position where the card is inserted. Valid values: psA(1),psB(2),clA(3),clB(4),io1(5)..io12(16); notApplicable=255.
OBJECT-TYPE    
  Integer32  

agnXCmprIdx5 1.3.6.1.4.1.164.3.1.2.3.7.1.5
5th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt12 (12) , inPrt1 (101) .. inPrt48 (148).
OBJECT-TYPE    
  Integer32  

agnXCmprIdx6 1.3.6.1.4.1.164.3.1.2.3.7.1.6
6th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates the Variant index. Valid values are: 0..127, 255 (= temp cnfg).Set can be performed only to the temporary configuration.
OBJECT-TYPE    
  Integer32  

agnXCmprIdx7 1.3.6.1.4.1.164.3.1.2.3.7.1.7
7th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute is not needed. Therefore, its value will be always 255=notApplicable.
OBJECT-TYPE    
  Integer32  

agnXCmprObj 1.3.6.1.4.1.164.3.1.2.3.7.1.8
This attribute is the compressed information itself.
OBJECT-TYPE    
  OCTET STRING  

alrBuffGen 1.3.6.1.4.1.164.3.1.2.4
OBJECT IDENTIFIER    

alrBufTable 1.3.6.1.4.1.164.3.1.2.4.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    AlrBufEntry

alrBufEntry 1.3.6.1.4.1.164.3.1.2.4.1.1
An entry in table.
OBJECT-TYPE    
  AlrBufEntry  

alrBufIdx 1.3.6.1.4.1.164.3.1.2.4.1.1.1
This attribute indicates a unique number to identify this entry
OBJECT-TYPE    
  Integer32  

alrBufDescription 1.3.6.1.4.1.164.3.1.2.4.1.1.2
This entry is a unique text description of the alarm in the buffer. The alarm description includes the following information: alarm code, slot id, card type, channel id , alarm text, alarm status, masked flag and event counter
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

agnFlipDb 1.3.6.1.4.1.164.3.1.2.5
OBJECT IDENTIFIER    

agnCAgendaTable 1.3.6.1.4.1.164.3.1.2.5.1
This table devides the week days into categories needed for DB flip consideration.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCAgendaEntry

agnCAgendaEntry 1.3.6.1.4.1.164.3.1.2.5.1.1
An entry in table.
OBJECT-TYPE    
  AgnCAgendaEntry  

agnCAgendaCnfgIdx 1.3.6.1.4.1.164.3.1.2.5.1.1.1
Active or Temporary Agenda Table. Both configurations can be read but only the Temporary can be written to.
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnCAgendaDayIdx 1.3.6.1.4.1.164.3.1.2.5.1.1.2
Day of week
OBJECT-TYPE    
  INTEGER sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7)  

agnCAgendaDayCategory 1.3.6.1.4.1.164.3.1.2.5.1.1.3
The Category of the Day
OBJECT-TYPE    
  INTEGER fullWorkday(1), partialWorkday(2), weekend(3)  

agnCFlipNetEventsTable 1.3.6.1.4.1.164.3.1.2.5.2
This table holds the Net Events the MUX should trace
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCFlipNetEventsEntry

agnCFlipNetEventsEntry 1.3.6.1.4.1.164.3.1.2.5.2.1
An entry in table.
OBJECT-TYPE    
  AgnCFlipNetEventsEntry  

agnCFlipNetEventsCnfgIdx 1.3.6.1.4.1.164.3.1.2.5.2.1.1
Active or Temporary Net Events Table. Both configurations can be read but only the Temporary can be written to.
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnCFlipNetEventIdx 1.3.6.1.4.1.164.3.1.2.5.2.1.2
Entry within the table
OBJECT-TYPE    
  Integer32 1..10  

agnCFlipNetEventActive 1.3.6.1.4.1.164.3.1.2.5.2.1.3
Indicates if the entry is valid. In order to Add/Modify parameters of an entry, this object should be set to Yes. In order to delete an entry, this object should be Set to No.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCFlipNetEventType 1.3.6.1.4.1.164.3.1.2.5.2.1.4
The Net Event type
OBJECT-TYPE    
  INTEGER time(1), linkDown(2), congestion(3)  

agnCFlipNetEventNo 1.3.6.1.4.1.164.3.1.2.5.2.1.5
The Net Event No. (Bit Index)
OBJECT-TYPE    
  Integer32 1..512  

agnCFlipNetEventSlot 1.3.6.1.4.1.164.3.1.2.5.2.1.6
The slot to which the net event relates . Not applicable for time event
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

agnCFlipNetEventPort 1.3.6.1.4.1.164.3.1.2.5.2.1.7
The port within the relevant slot. Valid values: - extPrt1(1)..exPrt16(16) - notApplicable(100) - inPrt1(101)..inPrt48(148)
OBJECT-TYPE    
  Integer32  

agnCFlipNetEventISD 1.3.6.1.4.1.164.3.1.2.5.2.1.8
The time in seconds since the Net Event was reported as ON until it is considered as ON. Not relevant for time events.
OBJECT-TYPE    
  Integer32 1..999  

agnCFlipNetEventOSD 1.3.6.1.4.1.164.3.1.2.5.2.1.9
The time in seconds since the net event was reported as OFF until it is considered as OFF. Not relevant for time events.
OBJECT-TYPE    
  Integer32 1..999  

agnCFlipNetEventDayType 1.3.6.1.4.1.164.3.1.2.5.2.1.10
The time event relates to all days defined in this category in the agnCAgendaTable. Applicable only for time event
OBJECT-TYPE    
  INTEGER notApplicable(1), fullWorkday(2), partialWorkday(3), weekend(4)  

agnCFlipNetEventStartTime 1.3.6.1.4.1.164.3.1.2.5.2.1.11
The time event will be activated at this time. The format is hh:mm.
OBJECT-TYPE    
  DisplayString SIZE(5)  

agnCFlipNetEventEndTime 1.3.6.1.4.1.164.3.1.2.5.2.1.12
The time event will be deactivated at this time. The format is hh:mm.
OBJECT-TYPE    
  DisplayString SIZE(5)  

agnCFlipTable 1.3.6.1.4.1.164.3.1.2.5.3
The DB Flip Decisions Table
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCFlipEntry

agnCFlipEntry 1.3.6.1.4.1.164.3.1.2.5.3.1
An entry in table.
OBJECT-TYPE    
  AgnCFlipEntry  

agnCFlipCnfgIdx 1.3.6.1.4.1.164.3.1.2.5.3.1.1
Active or Temporary Flip Decisions Table. Both configurations can be read but only the Temporary can be written to.
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnCFlipIdx 1.3.6.1.4.1.164.3.1.2.5.3.1.2
Entry number within the table
OBJECT-TYPE    
  Integer32 1..10  

agnCFlipActive 1.3.6.1.4.1.164.3.1.2.5.3.1.3
Indicates if the entry is valid. In order to Add/Modify parameters of an entry this object should be Set to Yes. In order to delete an entry, this object should be Set to No.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCFlipLogicalExp 1.3.6.1.4.1.164.3.1.2.5.3.1.4
A logical expression composed of events numbers (which were configured in the 'AgnCFlipNetEvantsTable') and logical operators ('|', '&', '!', '(', ')') between them. e.g - (1 & !2) | (121 & 230)
OBJECT-TYPE    
  DisplayString SIZE(1..20)  

agnCFlipDbNo 1.3.6.1.4.1.164.3.1.2.5.3.1.5
The ID of the required DB
OBJECT-TYPE    
  Integer32 1..10  

agnCFlipDiscardDe 1.3.6.1.4.1.164.3.1.2.5.3.1.6
Indicates whether the Mux should start discarding all DE. (MP3000 Only).
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

agnFlipDbControls 1.3.6.1.4.1.164.3.1.2.5.4
OBJECT IDENTIFIER    

agnCFlipDbSanityCheckCmd 1.3.6.1.4.1.164.3.1.2.5.4.1
Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and automatically be changed to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCSaveFlipDbCmd 1.3.6.1.4.1.164.3.1.2.5.4.2
Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and if it is OK, it will save the Flip Db in the NVRAM, activating the new Flip DB . If check detects errors, the save will not be performed. Afterwards, the object's value will change automatically to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCSaveNetCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.5.4.3
This attribute specifies the Id of the target NVRAM Cnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown. This attribute doesn't cause actual Flip.
OBJECT-TYPE    
  Integer32 1..10  

agnCSaveNetFlipDbCmd 1.3.6.1.4.1.164.3.1.2.5.4.4
Setting this attribute to on(3) will save the Temp Flip DB Into the NVRAM without actual flip.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCNetGoCmd 1.3.6.1.4.1.164.3.1.2.5.4.5
Setting this attribute to On will broadcast a 'GO' command to the network. When a Mux receives a 'GO' command it issues a delay for 'agnCNetDelay' seconds and then activates the DB which was pre-defined by one of the commands : 'agnCSaveNetCnfgIdxCmd' or 'agnCSaveNetFlipDbCmd'.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCNetDelay 1.3.6.1.4.1.164.3.1.2.5.4.6
This attribute determines the period of time in seconds that takes for a message to be transferred over all the network. After a 'GO' command the MUX issues a delay of 'agnCNetDelay' before activating the appropriate DB. The delay will be applied only after performing agnCSaveFlipDbCmd.
OBJECT-TYPE    
  Integer32 1..999  

agnCNetEventsBcast 1.3.6.1.4.1.164.3.1.2.5.4.7
This object determines if the Net Events will be Broadcasted to other Muxes of the Net or not. disabled - Net Events will NOT be Broadcasted enabled - Net Events will be Broadcasted. Default=disabled. The value will be applied only after performing agnCSaveFlipDbCmd.
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

agnCNetEventsBcastInterval 1.3.6.1.4.1.164.3.1.2.5.4.8
When agnCNetEventsBcast is enabled, this object determines the interval of time in seconds, between two consecutive Net Events transferred over the network. Default=40 sec. The interval will be applied only after performing agnCSaveFlipDbCmd.
OBJECT-TYPE    
  Integer32 10..60  

agnSa 1.3.6.1.4.1.164.3.1.2.6
OBJECT IDENTIFIER    

agnSaSwchStatus 1.3.6.1.4.1.164.3.1.2.6.1
This object indicates the status of the switches on the stand-alone unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits: bit 0 NMS (LSB) bit 1 Terminal '1' = forces the DCE to be terminal with Rate=9600bps, Data bits=8, Stop bits=1 bit 2 Xray bit 3 SW-Load '1' = when SW is loaded bit 4 DBS Default of all bits=0 When the status of these switches is unknown, the value of this object is 255.
OBJECT-TYPE    
  Integer32  

agnListDecoding 1.3.6.1.4.1.164.3.1.2.7
OBJECT IDENTIFIER    

agnListDecodingTable 1.3.6.1.4.1.164.3.1.2.7.1
A decoding table . For each type of list, a description is given for each existing code.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnListDecodingEntry

agnListDecodingEntry 1.3.6.1.4.1.164.3.1.2.7.1.1
An entry in table.
OBJECT-TYPE    
  AgnListDecodingEntry  

agnListDecodingType 1.3.6.1.4.1.164.3.1.2.7.1.1.1
The type of list the decoding data refers to. alr - Alarms list sanity - Sanity Check Error list.
OBJECT-TYPE    
  INTEGER alr(1), sanity(2)  

agnListDecodingCode 1.3.6.1.4.1.164.3.1.2.7.1.1.2
The specific code for which decoding is needed.
OBJECT-TYPE    
  Integer32  

agnListDecodingDescription 1.3.6.1.4.1.164.3.1.2.7.1.1.3
The description fitting the specific code and type of list required.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

agnListDecodingDefState 1.3.6.1.4.1.164.3.1.2.7.1.1.4
This object is applicable only for agnListDecodingType=alr. It reports the default state/severity of each alarm. User can change the severity of the alarms defined by this default via the agnListDecodingSeverity object.
OBJECT-TYPE    
  INTEGER notApplicable(1), event(3), minor(4), major(5), warning(6), critical(7)  

agnListDecodingSeverity 1.3.6.1.4.1.164.3.1.2.7.1.1.5
This object is applicable only for agnListDecodingType=alr. It enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code). event - can be set only for an alarm that is defined by default as 'event'. User can change the severity of the alarms defined by default as minor or major. The severity of an event may be set to another severity, but the change will actually happen only if the event threshold is active and passed the Set/ON condition. An event alarm that passed the threshold and changed its severity, will return automatically to event severity when meeting its Reset/OFF condition.
OBJECT-TYPE    
  INTEGER notApplicable(1), event(3), minor(4), major(5), warning(6), critical(7)  

agnListDecodingAcmRelaySlt 1.3.6.1.4.1.164.3.1.2.7.1.1.6
This object indicates the ACM slot, desired for outbound relay (report) for the selected alarm. In the ?004 Unit the entries io6(10)..io12(16) are not valid. none - when agnListDecodingType=alr AND the selected alarm should not be reported by an ACM card. notApplicable - when agnListDecodingType=sanity OR when [agnListDecodingType=alr and there is no ACM card installed in the Mux].
OBJECT-TYPE    
  INTEGER none(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnListDecodingAcmRelayPrt 1.3.6.1.4.1.164.3.1.2.7.1.1.7
This object indicates the ACM port within the slot, desired for outbound relay (report) for the selected alarm. notApplicable - when agnListDecodingType=sanity OR when agnListDecodingAcmRelaySlt=notApplicable.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), notApplicable(255)  

agnSystemDlci 1.3.6.1.4.1.164.3.1.2.8
OBJECT IDENTIFIER    

agnDlciTable 1.3.6.1.4.1.164.3.1.2.8.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnDlciEntry

agnDlciEntry 1.3.6.1.4.1.164.3.1.2.8.1.1
An entry in table.
OBJECT-TYPE    
  AgnDlciEntry  

agnDlciCnfgIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

agnDlciLSltIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.2
This attribute indicates a unique slot position where the card is inserted. vs=Voice Switching In the ?004 Unit the entries io6(10)..io16) are not valid. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) LSlotIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
OBJECT-TYPE    
  INTEGER cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), vs(254), notApplicable(255)  

agnDlciLPrtIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.3
This attribute indicates a unique external or internal port number, including linkSelector or encapsulator. 100=noConnect (for voice switching) LPrtIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
OBJECT-TYPE    
  Integer32  

agnDlciLIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.4
This attribute indicates a unique index for each possible used dlci(16..991). 0=notApplicable (for voice switching) LIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
OBJECT-TYPE    
  Integer32 0..991  

agnDlciHSltIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.5
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io16) are not valid
OBJECT-TYPE    
  INTEGER cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnDlciHPrtIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.6
This attribute indicates a unique port id which the dlci is routed to.
OBJECT-TYPE    
  Integer32  

agnDlciHIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.7
This attribute indicates a unique internal connection dlci number which the src dlci is routed to.
OBJECT-TYPE    
  Integer32 1..991  

agnDlciTxBc 1.3.6.1.4.1.164.3.1.2.8.1.1.8
This attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line.
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc5100bps(3), txBc6400bps(4), txBc8300bps(5), txBc9600bps(6), txBc14400bps(7), txBc19200bps(8), txBc28800bps(9), txBc32000bps(10), txBc38400bps(11), txBc48000bps(12), txBc56000bps(13), txBc57600bps(14), txBc64Kbps(15), txBc128Kbps(16), txBc192Kbps(17), txBc256Kbps(18), txBc320Kbps(19), txBc384Kbps(20), txBc448Kbps(21), txBc512Kbps(22), txBc768Kbps(23), txBc896Kbps(24), txBc1024Kbps(25), txBc1152Kbps(26), txBc1280Kbps(27), txBc1344Kbps(28), txBc1472Kbps(29), txBc1600Kbps(30), txBc1728Kbps(31), txBc1856Kbps(32), txBc1920Kbps(33), txBc1984Kbps(34), txBc2048Kbps(35), txBc16000bps(36), txBc112Kbps(37), txBc168Kbps(38), txBc224Kbps(39), txBc336Kbps(40), txBc672Kbps(41), txBc1536Kbps(42), txBc1792Kbps(43)  

agnDlciTxBe 1.3.6.1.4.1.164.3.1.2.8.1.1.9
This attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line.
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe5100bps(3), txBe6400bps(4), txBe8300bps(5), txBe9600bps(6), txBe14400bps(7), txBe19200bps(8), txBe28800bps(9), txBe32000bps(10), txBe38400bps(11), txBe48000bps(12), txBe56000bps(13), txBe57600bps(14), txBe64Kbps(15), txBe128Kbps(16), txBe192Kbps(17), txBe256Kbps(18), txBe320Kbps(19), txBe384Kbps(20), txBe448Kbps(21), txBe512Kbps(22), txBe768Kbps(23), txBe896Kbps(24), txBe1024Kbps(25), txBe1152Kbps(26), txBe1280Kbps(27), txBe1344Kbps(28), txBe1472Kbps(29), txBe1600Kbps(30), txBe1728Kbps(31), txBe1856Kbps(32), txBe1920Kbps(33), txBe1984Kbps(34), txBe2048Kbps(35), txBe16000bps(36), txBe112Kbps(37), txBe168Kbps(38), txBe224Kbps(39), txBe336Kbps(40), txBe672Kbps(41), txBe1536Kbps(42), txBe1792Kbps(43)  

agnDlciRxBc 1.3.6.1.4.1.164.3.1.2.8.1.1.10
This attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line.
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc5100bps(3), rxBc6400bps(4), rxBc8300bps(5), rxBc9600bps(6), rxBc14400bps(7), rxBc19200bps(8), rxBc28800bps(9), rxBc32000bps(10), rxBc38400bps(11), rxBc48000bps(12), rxBc56000bps(13), rxBc57600bps(14), rxBc64Kbps(15), rxBc128Kbps(16), rxBc192Kbps(17), rxBc256Kbps(18), rxBc320Kbps(19), rxBc384Kbps(20), rxBc448Kbps(21), rxBc512Kbps(22), rxBc768Kbps(23), rxBc896Kbps(24), rxBc1024Kbps(25), rxBc1152Kbps(26), rxBc1280Kbps(27), rxBc1344Kbps(28), rxBc1472Kbps(29), rxBc1600Kbps(30), rxBc1728Kbps(31), rxBc1856Kbps(32), rxBc1920Kbps(33), rxBc1984Kbps(34), rxBc2048Kbps(35), rxBc16000bps(36), rxBc112Kbps(37), rxBc168Kbps(38), rxBc224Kbps(39), rxBc336Kbps(40), rxBc672Kbps(41), rxBc1536Kbps(42), rxBc1792Kbps(43)  

agnDlciRxBe 1.3.6.1.4.1.164.3.1.2.8.1.1.11
This attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line.
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe5100bps(3), rxBe6400bps(4), rxBe8300bps(5), rxBe9600bps(6), rxBe14400bps(7), rxBe19200bps(8), rxBe28800bps(9), rxBe32000bps(10), rxBe38400bps(11), rxBe48000bps(12), rxBe56000bps(13), rxBe57600bps(14), rxBe64Kbps(15), rxBe128Kbps(16), rxBe192Kbps(17), rxBe256Kbps(18), rxBe320Kbps(19), rxBe384Kbps(20), rxBe448Kbps(21), rxBe512Kbps(22), rxBe768Kbps(23), rxBe896Kbps(24), rxBe1024Kbps(25), rxBe1152Kbps(26), rxBe1280Kbps(27), rxBe1344Kbps(28), rxBe1472Kbps(29), rxBe1600Kbps(30), rxBe1728Kbps(31), rxBe1856Kbps(32), rxBe1920Kbps(33), rxBe1984Kbps(34), rxBe2048Kbps(35), rxBe16000bps(36), rxBe112Kbps(37), rxBe168Kbps(38), rxBe224Kbps(39), rxBe336Kbps(40), rxBe672Kbps(41), rxBe1536Kbps(42), rxBe1792Kbps(43)  

agnDlciPriority 1.3.6.1.4.1.164.3.1.2.8.1.1.12
This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 7 is the highest priority.
OBJECT-TYPE    
  Integer32 1..8  

agnDlciStatus 1.3.6.1.4.1.164.3.1.2.8.1.1.13
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

agnDlciSpoofing 1.3.6.1.4.1.164.3.1.2.8.1.1.14
This object refers to sending of RIP messages: - yes : RIP messages will be sent ONLY if there is a change in the Net. - no : RIP messages will be always sent. This object is relevant only when one side of the DLCI is a CL-NMS interface. Default=no.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnDlciFunnelEnable 1.3.6.1.4.1.164.3.1.2.8.1.1.15
This object selects Funnel activation enable/disable: - disabled: Funnel operation disabled. The agnDlciTxBe and agnDlciTxBc values are not used for funneling. - enabled : Funnel operation enabled. The agnDlciTxBe and agnDlciTxBc values are used for funneling calculations. This object is relevant only for an encapsulating DLCI. In case of a Link Selector DLCI, the agnDlciTxBe and agnDlciTxBc values are used for bandwidth of Link Selector. Default=disabled.
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

agnDlciRoutingProtocol 1.3.6.1.4.1.164.3.1.2.8.1.1.16
This object is relevant only when one side of the DLCI is a CL-NMS interface. It defines which Routing Protocol will be used for management via CL-NMS port. notApplicable will be used for all slots but CL. rip is a proprietary rip protocol. Default=rip.
OBJECT-TYPE    
  INTEGER notApplicable(1), rip(2), rip2(3), none(4)  

agnDlciRowStatus 1.3.6.1.4.1.164.3.1.2.8.1.1.17
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set agnRowStatus.255.id2.id3.id4.id5.id6.id7 = active(1). For destroying a row, the NMS should set: agnRowStatus.255.id2.id3.id4.id5.id6.id7 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

agnVoiceSwitching 1.3.6.1.4.1.164.3.1.2.9
OBJECT IDENTIFIER    

agnVoiceSwConfTable 1.3.6.1.4.1.164.3.1.2.9.1
MXcess Configuration for Voice Switching.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnVoiceSwConfEntry

agnVoiceSwConfEntry 1.3.6.1.4.1.164.3.1.2.9.1.1
An entry in table.
OBJECT-TYPE    
  AgnVoiceSwConfEntry  

agnVoiceSwConfIdx 1.3.6.1.4.1.164.3.1.2.9.1.1.1
Active or Temporary Table. Both configurations can be read but only the Temporary can be written to.
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnVoiceSwConfZoneId 1.3.6.1.4.1.164.3.1.2.9.1.1.2
1 or 2 digits, (0-9)(1-9).
OBJECT-TYPE    
  DisplayString SIZE(1..2)  

agnVoiceSwConfNodeId 1.3.6.1.4.1.164.3.1.2.9.1.1.3
1, 2 or 3 digits, (1-9),(0-9),(0-9).
OBJECT-TYPE    
  DisplayString SIZE(1..3)  

agnVoiceSwConfNoOfHops 1.3.6.1.4.1.164.3.1.2.9.1.1.4
Number of hops the frame will go through the net before deciding to discard the frame (like time-to-live in IP). 0 = notApplicable Default=20 .
OBJECT-TYPE    
  Integer32 0..20  

agnVoiceSwConfSidt 1.3.6.1.4.1.164.3.1.2.9.1.1.5
SIDT: Short Inter Digit Timeout used as timer (in sec.) between digits after routing is completed. The timeout indicates end of dialing and the call can then be setup. 0 = notApplicable Default=2 sec.
OBJECT-TYPE    
  Integer32 0..30  

agnVoiceSwConfLidt 1.3.6.1.4.1.164.3.1.2.9.1.1.6
LIDT: Long Inter Digit Timeout used as timer between digits before routing is completed. If no digits were dialed and LIDT expired then the user will get an error tone and the call will be disconnected. 0 = notApplicable Default=15 sec.
OBJECT-TYPE    
  Integer32 0..30  

agnVoiceSwConfDialPlan 1.3.6.1.4.1.164.3.1.2.9.1.1.7
This is the Dialing Plan method that will be used in the Voice Switching. Static Dialing Plan - Routing is defined by the current device Zone and Node ID in the Network. Static Dialing Plan Plus - Includes the Static Dialing Plan but contains an addition of defining the number of dialed digits. Flexible Dialing Plan - Routing is defined in a flexible form. In this plan the user can configure the extension number of a local voice channel, Route a call to a remote destination and enter the Number of Digits for a specific dial prefix.
OBJECT-TYPE    
  INTEGER staticDialPlan(2), staticDialPlanPlus(3), flexDialPlan(4)  

agnVoiceSwConfRtTable 1.3.6.1.4.1.164.3.1.2.9.2
Routing Table for Voice Switching.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnVoiceSwConfRtEntry

agnVoiceSwConfRtEntry 1.3.6.1.4.1.164.3.1.2.9.2.1
An entry in table.
OBJECT-TYPE    
  AgnVoiceSwConfRtEntry  

agnVoiceSwConfRtDbId 1.3.6.1.4.1.164.3.1.2.9.2.1.1
Active or Temporary Table. Both configurations can be read but only the Temporary can be written to.
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnVoiceSwConfRtIdx 1.3.6.1.4.1.164.3.1.2.9.2.1.2
The Index of the row.
OBJECT-TYPE    
  Integer32  

agnVoiceSwConfRtDigits 1.3.6.1.4.1.164.3.1.2.9.2.1.3
Dialed digits: Series of digits 0...9, '*', '#' or '%'. The '*' and '#' can have many uses according to the user's decision. For example, they can be used as part of the Dialed Number, they exist on the phone number panel. '*' can also be used instead of a series of numbers. The '%' means any digits (wildcard) and is used without a series of digits. When the agnVoiceSwConfRtAction is del (7), the series of digits that are configured via this MIB object will be deleted from the prefix of the dialed number.
OBJECT-TYPE    
  DisplayString SIZE(1..7)  

agnVoiceSwConfRtAction 1.3.6.1.4.1.164.3.1.2.9.2.1.4
Action that the system should perform for the digits: agnVoiceSwConfRtDigits. The action that is allowed depends on the Dialing Plan. Here is the list of the allowed actions: For Static Dialing Plan - zone, node, in, shortDialing, hgr, del, rep For Static Dialing Plan Plus - zone, node, in, shortDialing, hgr, del, rep, numDigDP For Flexible Dialing Plan - hgr, del, rep, numDigDP, route, ext
OBJECT-TYPE    
  INTEGER notApplicable(1), zone(2), node(3), shortDialing(4), in(5), hgr(6), del(7), rep(8), pri(9), bri(10), numDigDP(11), route(12), ext(13)  

agnVoiceSwConfRtData 1.3.6.1.4.1.164.3.1.2.9.2.1.5
This field is relevant for actions hgr(6), and rep(8), numDigDP(11) and contains the following information: For hgr - the number of the Hunt Group. For rep - the number of digits to be replaced with. For numDigDP - the number of digits collected before establishing the call. 0 indicates no defined length. In this case SIDT will be used.
OBJECT-TYPE    
  DisplayString SIZE(1..7)  

agnVoiceSwConfRtSlot 1.3.6.1.4.1.164.3.1.2.9.2.1.6
Routing Slot- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13).
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnVoiceSwConfRtPort 1.3.6.1.4.1.164.3.1.2.9.2.1.7
Routing Port- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13). 100=noConnect (for non-routing case).
OBJECT-TYPE    
  Integer32  

agnVoiceSwConfRtDlci 1.3.6.1.4.1.164.3.1.2.9.2.1.8
Routing DLCI- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13). Valid values: 0=notApplicable (for non-routing case). 1, 16..991
OBJECT-TYPE    
  Integer32  

agnVoiceSwConfRtRowStatus 1.3.6.1.4.1.164.3.1.2.9.2.1.9
Status of the row for creating/deleting entries in the table. The only possible supported RowStatus vaules are active (1), notInService (2), notReady(3), createAndGo(4), createAndWait(5) and destroy(6).
OBJECT-TYPE    
  RowStatus  

agnVoiceSwConfRtMaxCalls 1.3.6.1.4.1.164.3.1.2.9.2.1.10
Maximum no. of simultaneous voice calls that are allowed in the direction defined by the current entry. Default=0 (No Limit).
OBJECT-TYPE    
  Integer32  

agnVoiceSwConfHGTable 1.3.6.1.4.1.164.3.1.2.9.5
Table of Hunt Groups.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnVoiceSwConfHGEntry

agnVoiceSwConfHGEntry 1.3.6.1.4.1.164.3.1.2.9.5.1
An entry in table.
OBJECT-TYPE    
  AgnVoiceSwConfHGEntry  

agnVoiceSwConfHGdbIdx 1.3.6.1.4.1.164.3.1.2.9.5.1.1
Active or Temporary Table. Both configurations can be read but only the Temporary can be written to.
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnVoiceSwConfHGIdx 1.3.6.1.4.1.164.3.1.2.9.5.1.2
There may be up to 10 Hunt Groups per MXcess. That's the index of the hunt group relevant to this row.
OBJECT-TYPE    
  Integer32 1..10  

agnVoiceSwConfHGConnect 1.3.6.1.4.1.164.3.1.2.9.5.1.3
This attribute indicates whether the hunt group should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnVoiceSwConfHGExt 1.3.6.1.4.1.164.3.1.2.9.5.1.4
This is the extension number of the hunt group. 0 is for not valid. The allowed range is 10 - 99.
OBJECT-TYPE    
  Integer32 0..99  

agnSigProfile 1.3.6.1.4.1.164.3.1.2.10
OBJECT IDENTIFIER    

agnSigProfileTable 1.3.6.1.4.1.164.3.1.2.10.1
The write operation into the Table Objects is valid only to the TmpCnfg entry. The table includes signaling profile parameters for Legacy Profiles.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSigProfileEntry

agnSigProfileEntry 1.3.6.1.4.1.164.3.1.2.10.1.1
An entry in table.
OBJECT-TYPE    
  AgnSigProfileEntry  

agnSigProfileCnfgIdx 1.3.6.1.4.1.164.3.1.2.10.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

agnSigProfileIdx 1.3.6.1.4.1.164.3.1.2.10.1.1.2
This attribute indicates the Signaling Profile (1..5).
OBJECT-TYPE    
  Integer32 1..5  

agnSigProfileRxTx 1.3.6.1.4.1.164.3.1.2.10.1.1.3
This attribute indicates if the following objects refer to: Rx or Tx translation. Rx : ML->IO Tx : IO->ML .
OBJECT-TYPE    
  INTEGER rx(1), tx(2)  

agnSigProfileABCD 1.3.6.1.4.1.164.3.1.2.10.1.1.4
This object represents 6 parameters, by 3 Octets : Busy Code-MSB nibble, - applicable only for Rx translation Idle Code- nibble, - applicable only for Rx translation D Bit Code- nibble, C Bit Code- nibble, B Bit Code- nibble, A Bit Code-LSB nibble. Each of Busy and Idle Code nibble will have the valid values: 0000 .. FFFF. Each of A,B,C,D Bit Code nibble represents: 0 hex = 0000 = 0 1 hex = 0001 = 1 2 hex = 0010 = A bit 3 hex = 0011 = B bit 4 hex = 0100 = C bit 5 hex = 0101 = D bit 6 hex = 0110 = A bit inverse 7 hex = 0111 = B bit inverse 8 hex = 1000 = C bit inverse 9 hex = 1001 = D bit inverse A-F hex - not used (invalid values) When the object is not applicable, the Octet String will have 0 bytes.
OBJECT-TYPE    
  OCTET STRING  

agnSigProfTable 1.3.6.1.4.1.164.3.1.2.10.2
The write operation into the Table Objects is valid only to the TmpCnfg entry. This is the general table of signaling profiles.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSigProfEntry

agnSigProfEntry 1.3.6.1.4.1.164.3.1.2.10.2.1
An entry in table.
OBJECT-TYPE    
  AgnSigProfEntry  

agnSigProfCnfgIdx 1.3.6.1.4.1.164.3.1.2.10.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

agnSigProfIdx 1.3.6.1.4.1.164.3.1.2.10.2.1.2
This attribute indicates the Signaling Profile (1..5).
OBJECT-TYPE    
  Integer32 1..5  

agnSigProfName 1.3.6.1.4.1.164.3.1.2.10.2.1.3
Profile Name given by user.
OBJECT-TYPE    
  DisplayString SIZE(0..12)  

agnSigProfType 1.3.6.1.4.1.164.3.1.2.10.2.1.4
Profile Type. legacy - usual signaling. The parameters for the Legacy Profiles are detailed in the agnSigProfileTable, above. r2Cas - R2 signaling. The parameters for the R2 Profiles are detailed in the r2 ProfileCnfg tables (belong to r2If).
OBJECT-TYPE    
  INTEGER notApplicable(1), legacy(2), r2Cas(3)  

agnSystemTs 1.3.6.1.4.1.164.3.1.2.11
OBJECT IDENTIFIER    

agnTsTable 1.3.6.1.4.1.164.3.1.2.11.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnTsEntry

agnTsEntry 1.3.6.1.4.1.164.3.1.2.11.1.1
An entry in table.
OBJECT-TYPE    
  AgnTsEntry  

agnTsCnfgIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

agnTsSltIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.2
This attribute indicates a unique slot position where the card is inserted.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

agnTsPrtIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.3
This attribute indicates a unique external or internal port number. For MP, the valid values will be (for MLs only): - exPrt1(1)..exPrt4(4) - inPrt1(101)..inPrt4(104)
OBJECT-TYPE    
  Integer32  

agnTsIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.4
This attribute indicates a unique index for TS (Time-Slot). - for T1 ports - 1..24, Fbit(25) - for E1 ports - 1..31 - for HDSL ports - 1..32 ; 32 will represent TS0.
OBJECT-TYPE    
  Integer32 1..32  

agnTsBitIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.5
This attribute indicates a unique index for the Bit of each TS (Time-Slot). 1..8 - Bit 1.. Bit 8 255 - notApplicable This object is applicable only in Split Time-Slot cases.
OBJECT-TYPE    
  Integer32  

agnTsConSltIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.6
This attribute indicates a unique slot position In the Mux where the TS is routed to.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

agnTsConPrtIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.7
This attribute indicates a unique port id the TS is routed to. notApplicable - when agnTsType=mng or spare For MP: exPrt1 (1) .. exPrt16 (16) , notApplicable(100), inPrt1 (101) .. inPrt48 (148).
OBJECT-TYPE    
  Integer32  

agnTsConIdx 1.3.6.1.4.1.164.3.1.2.11.1.1.8
This attribute indicates a unique TS number the Src TS is routed to. Valid values: - for T1 ports - 1..24, Fbit(25) - for E1 ports - 1..31 - for HDSL ports - 1..32 ; 32 will represent TS0. - notApplicable - 255 (for ports that don't have TSs).
OBJECT-TYPE    
  Integer32 1..255  

agnTsType 1.3.6.1.4.1.164.3.1.2.11.1.1.9
Time-Slot Type - regarding its connection and media type. voice, data, vcMP - connected and the media is specified. mng - management. This TS is Dedicated to Management (not disconnected, but not connected to another port). spare - applicable for ML-20 only. These TSs should be reserved for future connection, though at the moment are not connected. reserved - these TSs are not connected, but they are Reserved for Protection (back-up) of a certain Path. Therefore, should NOT be used for connection of other Paths. dChannel - is used only when the TS is connected to a V5.1 ML (Bypass) and it contains ISDN D Channel data. In this case, agnTsConSltIdx, agnTsConPrtIdx and agnTsConIdx, will be 'notApplicable', since no TS is assigned for D Ch in V5.1 ML.
OBJECT-TYPE    
  INTEGER unknown(1), voice(2), data(3), vcMP(4), mng(6), spare(7), reserved(8), dChannel(9)  

agnTsRowStatus 1.3.6.1.4.1.164.3.1.2.11.1.1.10
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set agnTsRowStatus.255.id2.id3.id4.id5.id6.id7.id8 = active(1). For destroying a row, the NMS should set: agnTsRowStatus.255.id2.id3.id4.id5.id6.id7.id8 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

agnTsDirection 1.3.6.1.4.1.164.3.1.2.11.1.1.11
Direction of the connection. This parameter is especially important when in MP a ML is connected to an IO port that has no TSs, so it doesn't appear in the TS Assignment for the first 5 indexes. notApplicable - for products that do not support this object or for certain TS Types (for example: mng, spare) rx - the ML only Receives from the IO Port (the ML will appear in the first 5 indexes). tx - the ML only Transmits to the IO Port (the ML will appear in the first 5 indexes). Nothing is received back. both - the ML Receives and Transmits to the IO Port (the ML will appear in the first 5 indexes). bcastSrc - the ML is a Broadcast-Bidirectional Source. It Transmits to one or several IO Ports (including the one that appears in the last 3 indexes) and sometimes receives. The Port that responds is dynamic (it can be another each time). The ML will appear in the first 5 indexes. bcastDst - the ML is a Broadcast-Bidirectional Destination. Therefore, it Receives and sometimes Transmits. The ML will appear in the first 5 indexes. internal - for connection of TSs internally, within the same card. Such an assignment has no effect on the external TS connections of the same TS. A TS can be connected with 'internal' direction to a port of the same card and at the same time, connected by another direction to ports (and TSs) of other cards.
OBJECT-TYPE    
  INTEGER notApplicable(1), rx(2), tx(3), both(4), bcastSrc(5), bcastDst(6), internal(7)  

systemVoice 1.3.6.1.4.1.164.3.1.2.12
OBJECT IDENTIFIER    

systemVoiceTable 1.3.6.1.4.1.164.3.1.2.12.1
General Parameters for voice - system level.
OBJECT-TYPE    
  SEQUENCE OF  
    SystemVoiceEntry

systemVoiceEntry 1.3.6.1.4.1.164.3.1.2.12.1.1
An entry in table.
OBJECT-TYPE    
  SystemVoiceEntry  

systemVoiceConfIdx 1.3.6.1.4.1.164.3.1.2.12.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed - Active or Temporary Configurations. Idx 255 relates to the temporary TmpCnfg. All configurations can be read but only the Temporary can be written to.
OBJECT-TYPE    
  Integer32  

systemVoiceNationalTone 1.3.6.1.4.1.164.3.1.2.12.1.1.2
Tone Characteristics (Amplitude, Frequency, delays etc.). These characteristics are defined according to the country.
OBJECT-TYPE    
  INTEGER notApplicable(1), usa(2), australia(3), brazil(4), canada(5), france(6), germany(7), israel(8), mexico(9), portugal(10), russia(11), spain(12), unitedKingdom(13), czech(14), china(15)  

mdlWanGen 1.3.6.1.4.1.164.3.1.3
OBJECT IDENTIFIER    

statMdlGen 1.3.6.1.4.1.164.3.1.3.1
OBJECT IDENTIFIER    

mdlSInstTable 1.3.6.1.4.1.164.3.1.3.1.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlSInstEntry

mdlSInstEntry 1.3.6.1.4.1.164.3.1.3.1.1.1
An entry in table.
OBJECT-TYPE    
  MdlSInstEntry  

mdlSInstSltIdx 1.3.6.1.4.1.164.3.1.3.1.1.1.1
A unique number to identify a slot position in the mux. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlSInstCardType 1.3.6.1.4.1.164.3.1.3.1.1.1.2
This attribute indicates the type of card installed in the specific slot position. Only PS cards are possible in the PS slots. Only CL cards are possible in the CL slots. Only IO cards are possible in the IO slots.
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), acm(9), ps60W(10), ps100W(11), cl1(20), clEth(21), cl2(22), cl2Eth(23), cl3(24), cl3Eth(25), mPh1(31), mPh3(32), mPh1T1DSU(33), mPh1T1CSU(34), mPh1E1DSU(35), mPh1E1LTU(36), mtmlFT1(37), mtmlFE1(38), mtmlH4E1(39), mtmlH4E12W(40), mtmlH4T1(41), mtmlH4T12W(42), mtHsh4E1(43), mtHsh4E12W(44), mtHsh4T1(45), mtHsh4T12W(46), mtmlH2E1(47), mtmlH2E12W(48), mtmlH2T1(49), mtmlH2T12W(50), hsh2E1(51), hsh2E12W(52), hsh2T1(53), hsh2T12W(54), mlIp(55), mtml4Ip(56), mPl6(60), mPl3(61), ml2E1(68), ml4E1(69), ml2T1(70), ml4T1(71), mPv4(72), vc16A(73), vc8EandM(74), vc8Fxo(75), vc8Fxs(76), vc16EandM(77), vc16Fxo(78), vc16Fxs(79), vf3EandM(80), vf3Fxs(81), vf3Fxo(82), vfPbx(83), vfPbxT1(84), vfPbxE1(85), mtMlE2S(86), mtMlE2D(87), mtMlF2T1(88), mtMlF2E1(89), mtMlT1Fiber(90), mtMlE1Fiber(91), mtMlT1FiberFb(92), mtMlE1FiberFb(93), mtmlHE1(94), mtmlH1E1(95), mtmlHSE1(96), ml20(97), mtMl4T1(98), mtMl4E1(99), mtMl1T1DSU(100), mtMl1T1CSU(101), mtMl1E1DSU(102), mtMl1E1LTU(103), mtMl1T1DSUfb(104), mtMl1T1CSUfb(105), mtMl1E1DSUfb(106), mtMl1E1LTUfb(107), mtMl2T1(108), mtMl2E1(109), ls2CcittX50(110), ls2CcittX58(111), ls2ATandTSdm(112), ls2ACcittX50(113), ls2ACcittX58(114), ls2AATandTSdm(115), ls2A2Ts(116), ls2M(117), mtMlT1(118), mtMlE1(119), hs2(120), hs3(121), hsq(122), hs703(123), hsQM(124), hsqN(125), hs6(126), hs12(127), hsDp(128), hsp(129), hs4T1(130), hs4E1(131), hs4(132), hsEth(133), vc2E1(136), vc4E1(137), vc2T1(138), vc4T1(139), vc2EandM(140), vc2Fxs1Plar(141), vc2Fxo1(142), vc2Fxs2(143), vc2Fxo2(144), vc2Fxs3(145), vc2Fxo3(146), vc26EandM(147), mtvc2(148), vc2R2Fxs(149), hsu(150), mbeA(151), mbeB(152), mbeU(153), tre(154), hsuI(155), hsr(156), hss(157), hsu1(158), ls12(159), ls6(160), ls6V1EandM(161), ls6V1Fxo(162), ls6V1Fxs(163), ls6V2EandM(164), ls6V2Fxo(165), ls6V2Fxs(166), ls6VfEandM(167), ls6VfFxo(168), ls6VfFxs(169), vc3EandM(170), vc3Fxo(171), vc3Fxs(172), vcPbx(173), vcPbxT1(174), vcPbxE1(175), vc6EandM(176), vc6Fxo(177), vc6Fxs(178), vcq(179), ls6n(180), mhs1V36(181), mhs1V35(182), mhs1G703(183), mhs1DDS(184), mhs3(185), mhs1X21(186), mhs1V24(187), mhs4(188), mhsE1Hs(189), mhsT1Hs(190), mhsHyE1Hs(191), mhsHyT1Hs(192), mlfHybE1Hs(193), mlfHybT1Hs(194), mhs2e1(195), mhs2t1(196), mhsHy2e1(197), mhsHy2t1(198), mlfHybE12(199), mls6(200), mls3(201), mlHybAtmE1(202), mlHybAtmT1(203), mlfHybT12(204), mvc8(205), mvc8PbxE1(206), mvc8PbxT1Dsu(207), mvc8PbxT1Csu(208), mvc8PbxE1Slave(209), mvc4(210), mvc4PbxE1(211), mvc4PbxT1Dsu(212), mvc4PbxT1Csu(213), mvc4PbxE1Slave(214), mvc4PbxT1Slave(215), mvc8PbxT1Slave(216), mvc8ExtAnalog(217), mvcE1(218), mvcT1(219), mhsS(220), mhsU(221), mhsPriE1(222), mhsPriT1(223), mPriE1FramerCcs(225), mPriT1FramerCcs(226), mPriE1SlaveCcs(227), mPriT1SlaveCcs(228), mDualBri(229), vc12EandM(230), vc12Fxo(231), vc12Fxs(232), vc6aEandM(233), vc6aFxo(234), vc6aFxs(235), vc6AgFxo(236), vc6AgFxs(237), vc6a4LB(238), hsu12(240), hsu6(241), hss12(242), hss6(243), mhsHyE1(247), mhsHyT1(248), mhsIp(249), mlIpHs(250), mlHybIpE1(251), mlHybIpT1(252), mvg1Lan(253), mvg2Lan(254)  

mdlSHwVersion 1.3.6.1.4.1.164.3.1.3.1.1.1.3
This attribute indicates the Hardware version of the installed card in the specific slot position.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

mdlSSwVersion 1.3.6.1.4.1.164.3.1.3.1.1.1.4
This attribute indicates the Software version of the installed card in the specific slot position.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

mdlSAlrStatus 1.3.6.1.4.1.164.3.1.3.1.1.1.5
Indicates the alarm state at module level, i.e. lower level (port alarms) status is not included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSAlrStatusAll 1.3.6.1.4.1.164.3.1.3.1.1.1.6
Indicates the alarm state in the module-all level, i.e. lower level (port alarms) included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSMaskedAlrStat 1.3.6.1.4.1.164.3.1.3.1.1.1.7
Indicates the alarm state at module level, [i.e. lower level (port alarms) status is not included],including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSMaskedAlrStatAll 1.3.6.1.4.1.164.3.1.3.1.1.1.8
Indicates the alarm state in the module-all level, i.e. lower level (port alarms) included, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSTstStatusAll 1.3.6.1.4.1.164.3.1.3.1.1.1.9
This attribute will be set to on(3) when there is at least one test in progress on a channel of the card, otherwise the value will be off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSClearAlrCmd 1.3.6.1.4.1.164.3.1.3.1.1.1.10
Setting this command to ON, enforces a clear of all the alarms in the given slot, excluding alarms of port level. The clear operation will not be applied for masked/inverted alarms.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSClearAllAlrCmd 1.3.6.1.4.1.164.3.1.3.1.1.1.11
Setting this command to ON, enforces a clear of all the alarms in the given slot, including all its ports alarms. The clear operation will not be applied for masked/inverted alarms.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrTable 1.3.6.1.4.1.164.3.1.3.1.2
The list of card agent alarms ; includes also an alarm indicating existence of alarms on its ports if there are any.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlSAlrEntry

mdlSAlrEntry 1.3.6.1.4.1.164.3.1.3.1.2.1
An entry in table.
OBJECT-TYPE    
  MdlSAlrEntry  

mdlSAlrIdx 1.3.6.1.4.1.164.3.1.3.1.2.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive.
OBJECT-TYPE    
  Integer32  

mdlSAlrSltIdx 1.3.6.1.4.1.164.3.1.3.1.2.1.2
This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlSAlrCodeDescription 1.3.6.1.4.1.164.3.1.3.1.2.1.3
This attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

mdlSAlrCode 1.3.6.1.4.1.164.3.1.3.1.2.1.4
A code identifying the alarm of an entry in the alarm status table at card level.
OBJECT-TYPE    
  Integer32  

mdlSAlrSeverity 1.3.6.1.4.1.164.3.1.3.1.2.1.5
The severity of the alarm.
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

mdlSAlrState 1.3.6.1.4.1.164.3.1.3.1.2.1.6
State of the alarm.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrCounter 1.3.6.1.4.1.164.3.1.3.1.2.1.7
A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
OBJECT-TYPE    
  Integer32  

mdlSAlrMask 1.3.6.1.4.1.164.3.1.3.1.2.1.8
Alarm mask : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrInvert 1.3.6.1.4.1.164.3.1.3.1.2.1.9
Alarm invert : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

cnfgMdlGen 1.3.6.1.4.1.164.3.1.3.2
OBJECT IDENTIFIER    

mdlCPrgTable 1.3.6.1.4.1.164.3.1.3.2.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlCPrgEntry

mdlCPrgEntry 1.3.6.1.4.1.164.3.1.3.2.1.1
An entry in table.
OBJECT-TYPE    
  MdlCPrgEntry  

mdlCCnfgIdx 1.3.6.1.4.1.164.3.1.3.2.1.1.1
This attribute indicates the Idx of the Cnfg(1..100) being referred. Value 255 specifies the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

mdlCSltIdx 1.3.6.1.4.1.164.3.1.3.2.1.1.2
This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlCPrgCardType 1.3.6.1.4.1.164.3.1.3.2.1.1.3
This attribute indicates the type of card assigned to the specific slot in the common configuration. This object is identical in all the configurations (1..100). Only the TmpCnf(255) may have different value. The write operation is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), acm(9), ps48x60W(10), ps48x100W(11), ps110x60W(12), ps110x100W(13), ps220x60W(14), ps220x100W(15), ps180W(16), cl1(20), clEth(21), cl2(22), cl2Eth(23), cl3(24), cl3Eth(25), mPh1(31), mPh3(32), mPh1T1DSU(33), mPh1T1CSU(34), mPh1E1DSU(35), mPh1E1LTU(36), mtmlFT1(37), mtmlFE1(38), mtmlH4E1(39), mtmlH4E12W(40), mtmlH4T1(41), mtmlH4T12W(42), mtHsh4E1(43), mtHsh4E12W(44), mtHsh4T1(45), mtHsh4T12W(46), mtmlH2E1(47), mtmlH2E12W(48), mtmlH2T1(49), mtmlH2T12W(50), hsh2E1(51), hsh2E12W(52), hsh2T1(53), hsh2T12W(54), mlIp(55), mtml4Ip(56), mPl6(60), ml2E1(68), ml4E1(69), ml2T1(70), ml4T1(71), vc16A(73), vc8EandM(74), vc8Fxo(75), vc8Fxs(76), vc16EandM(77), vc16Fxo(78), vc16Fxs(79), vf3EandM(80), vf3Fxs(81), vf3Fxo(82), vfPbx(83), vfPbxT1(84), vfPbxE1(85), mtMlE2S(86), mtMlE2D(87), mtMlF2T1(88), mtMlF2E1(89), mtMlT1Fiber(90), mtMlE1Fiber(91), mtMlT1FiberFb(92), mtMlE1FiberFb(93), mtmlHE1(94), mtmlH1E1(95), mtmlHSE1(96), ml20(97), mtMl4T1(98), mtMl4E1(99), mtMl1T1DSU(100), mtMl1T1CSU(101), mtMl1E1DSU(102), mtMl1E1LTU(103), mtMl1T1DSUfb(104), mtMl1T1CSUfb(105), mtMl1E1DSUfb(106), mtMl1E1LTUfb(107), mtMl2T1(108), mtMl2E1(109), ls2CcittX50(110), ls2CcittX58(111), ls2ATandTSdm(112), ls2ACcittX50(113), ls2ACcittX58(114), ls2AATandTSdm(115), ls2A2Ts(116), ls2M(117), mtMlT1(118), mtMlE1(119), hs2(120), hs3(121), hsq(122), hs703(123), hsQM(124), hsqN(125), hs6(126), hs12(127), hsDp(128), hsp(129), hs4T1(130), hs4E1(131), hsEth(133), vc2E1(136), vc4E1(137), vc2T1(138), vc4T1(139), vc2EandM(140), vc2Fxs1Plar(141), vc2Fxo1(142), vc2Fxs2(143), vc2Fxo2(144), vc2Fxs3(145), vc2Fxo3(146), vc26EandM(147), mtvc2(148), vc2R2Fxs(149), hsu(150), mbeA(151), mbeB(152), mbeU(153), tre(154), hsuI(155), hsr(156), hss(157), hsu1(158), ls12(159), ls6(160), ls6V1EandM(161), ls6V1Fxo(162), ls6V1Fxs(163), ls6V2EandM(164), ls6V2Fxo(165), ls6V2Fxs(166), ls6VfEandM(167), ls6VfFxo(168), ls6VfFxs(169), vc3EandM(170), vc3Fxo(171), vc3Fxs(172), vcPbx(173), vcPbxT1(174), vcPbxE1(175), vc6EandM(176), vc6Fxo(177), vc6Fxs(178), vcq(179), ls6n(180), mhs1V36(181), mhs1V35(182), mhs1G703(183), mhs1DDS(184), mhs3(185), mhs1X21(186), mhs1V24(187), mhs4(188), mhsE1Hs(189), mhsT1Hs(190), mhsHyE1Hs(191), mhsHyT1Hs(192), mlfHybE1Hs(193), mlfHybT1Hs(194), mhs2e1(195), mhs2t1(196), mhsHy2e1(197), mhsHy2t1(198), mlfHybE12(199), mls6(200), mls3(201), mlHybAtmE1(202), mlHybAtmT1(203), mlfHybT12(204), mvc8(205), mvc8PbxE1(206), mvc8PbxT1Dsu(207), mvc8PbxT1Csu(208), mvc8PbxE1Slave(209), mvc4(210), mvc4PbxE1(211), mvc4PbxT1Dsu(212), mvc4PbxT1Csu(213), mvc4PbxE1Slave(214), mvc4PbxT1Slave(215), mvc8PbxT1Slave(216), mvc8ExtAnalog(217), mvcE1(218), mvcT1(219), mhsS(220), mhsU(221), mhsPriE1(222), mhsPriT1(223), mPriE1FramerCcs(225), mPriT1FramerCcs(226), mpriE1SlaveCcs(227), mpriT1SlaveCcs(228), mDualBri(229), vc12EandM(230), vc12Fxo(231), vc12Fxs(232), vc6aEandM(233), vc6aFxo(234), vc6aFxs(235), vc6AgFxo(236), vc6AgFxs(237), vc6a4LB(238), hsu12(240), hsu6(241), hss12(242), hss6(243), mhsHyE1(247), mhsHyT1(248), mhsIp(249), mlIpHs(250), mlHybIpE1(251), mlHybIpT1(252), mvg1Lan(253), mvg2Lan(254)  

mdlCNoOfExternPrt 1.3.6.1.4.1.164.3.1.3.2.1.1.4
Number of external ports in the programmed card of the specific slot position
OBJECT-TYPE    
  Integer32  

mdlCNoOfInternPrt 1.3.6.1.4.1.164.3.1.3.2.1.1.5
Number of internal ports in the programmed card of the specific slot position.
OBJECT-TYPE    
  Integer32  

mdlCWorkMode 1.3.6.1.4.1.164.3.1.3.2.1.1.6
Working mode of the card. The user may configure the card to work in a stand alone mode or integrated with the device. Example for use in MHS-IP cards: - standAlone - in this mode, the router works so that data is received via the LAN (Eth) port and is transmitted via the WAN (HS) external port without going through the MPH device. - integrated - in this mode, the router works so that it is integrated in the MPH and routes DLCIs into the device.
OBJECT-TYPE    
  INTEGER notApplicable(1), standAlone(2), integrated(3)  

cmprMdlGen 1.3.6.1.4.1.164.3.1.3.3
OBJECT IDENTIFIER    

mdlCmprTable 1.3.6.1.4.1.164.3.1.3.3.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlCmprEntry

mdlCmprEntry 1.3.6.1.4.1.164.3.1.3.3.1.1
An entry in table.
OBJECT-TYPE    
  MdlCmprEntry  

mdlCmprTypIdx 1.3.6.1.4.1.164.3.1.3.3.1.1.1
This attribute indicates the Type of the Compressed being referred.
OBJECT-TYPE    
  Integer32  

mdlCmprCnfgIdx 1.3.6.1.4.1.164.3.1.3.3.1.1.2
This attribute indicates the configuration to which the Compressed information is related.
OBJECT-TYPE    
  Integer32  

mdlCmprVersion 1.3.6.1.4.1.164.3.1.3.3.1.1.3
This attribute indicates the version of the internal format of the Compressed data
OBJECT-TYPE    
  Integer32  

mdlCmprSltIdx 1.3.6.1.4.1.164.3.1.3.3.1.1.4
This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlCmprObj 1.3.6.1.4.1.164.3.1.3.3.1.1.5
This attribute is the compressed information itself.
OBJECT-TYPE    
  OCTET STRING  

mdlAlarmsCmprTable 1.3.6.1.4.1.164.3.1.3.3.2
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlAlarmsCmprEntry

mdlAlarmsCmprEntry 1.3.6.1.4.1.164.3.1.3.3.2.1
An entry in table.
OBJECT-TYPE    
  MdlAlarmsCmprEntry  

mdlAlarmsCmprVersion 1.3.6.1.4.1.164.3.1.3.3.2.1.1
This attribute indicates the version of the internal format of the Compressed data
OBJECT-TYPE    
  Integer32  

mdlAlarmsCmprAlarmSlot 1.3.6.1.4.1.164.3.1.3.3.2.1.2
This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid.
OBJECT-TYPE    
  Integer32  

mdlAlarmsCmprAlarmIdx 1.3.6.1.4.1.164.3.1.3.3.2.1.3
A unique number to identify an entry in the alarm status table of the agent.
OBJECT-TYPE    
  Integer32  

mdlAlarmsCmprObj 1.3.6.1.4.1.164.3.1.3.3.2.1.4
This attribute is the compressed information itself.
OBJECT-TYPE    
  OCTET STRING  

prtWanGen 1.3.6.1.4.1.164.3.1.4
OBJECT IDENTIFIER    

statPrtGen 1.3.6.1.4.1.164.3.1.4.1
OBJECT IDENTIFIER    

prtSInstTable 1.3.6.1.4.1.164.3.1.4.1.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSInstEntry

prtSInstEntry 1.3.6.1.4.1.164.3.1.4.1.1.1
An entry in table.
OBJECT-TYPE    
  PrtSInstEntry  

prtSInstSltIdx 1.3.6.1.4.1.164.3.1.4.1.1.1.1
This attribute indicates a unique number to identify the slot where the card is inserted. In the ?004 Unit the entries io6(10)..io(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtSInstPrtIdx 1.3.6.1.4.1.164.3.1.4.1.1.1.2
This attribute indicates a unique number to identify a port in a specific card. The valid ports depend on the installed card: the valid external ports (interfaces) are (1..mdlCNoOfExternPrt) if any, and the valid internal ports are (101..100+mdlCNoOfInternPrt) if any. Generally: exPrt1 (1) .. exPrt16 (16),inPrt1 (101) .. inPrt48 (148) For the Vmux-2100 device: This index will have values of 1...4 for the physical ports & values of ifIndex for the bundles.
OBJECT-TYPE    
  Integer32  

prtSInstPrtType 1.3.6.1.4.1.164.3.1.4.1.1.1.3
This attribute describes the type of the designated port. In MX 3000 only external & internal options are used. All the other options are only for MX 30/300 which need special handling. In order to support interface types in MX 3000, return an ascii string for prtSInterfaceType in this table or support the general RAD value of physicalConnector. External port - is a port with a physical connector. Internal port - might be of two types: a) A composite port which collects a few external ports data into a common bandwidth (usually routed through DS1 link) b) A port which gets only part of the external ports (usually a few DS0's) The following types are used when all ports are external/ internal and the connector/interface type is necessary (for example, stand-alone units): High Speed port types Low Speed port types Voice port types, CL port types. ISDN Voice in MX 30/300 Phase 4: voiceS0 (16), voiceU (17) should be used. ISDN Voice in MX 30/300 Phase 5: voiceQsigS(18), voiceQsigU (19) should be used.
OBJECT-TYPE    
  INTEGER external(2), internal(3), highSpeedV35(4), highSpeedV24(5), highSpeedV36(6), highSpeedX21(7), highSpeedG703(8), highSpeedDDS(9), lowSpeed(10), voice(11), cl(12), isdns(13), isdnu(14), ethernet(15), voiceS0(16), voiceU(17), voiceQsigS(18), voiceQsigU(19)  

prtSInstIfIndex 1.3.6.1.4.1.164.3.1.4.1.1.1.4
This attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx the value will be '7fffffff'h.
OBJECT-TYPE    
  Integer32  

prtSActiveStatus 1.3.6.1.4.1.164.3.1.4.1.1.1.5
This attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the ch is not connected according to the active config. offLine(3) indicates that the ch is down (not working) because of any problem. onLine(4) indicates that the ch is up (working) offLineRedundancy(5) indicates that the ch is down, because it is redundant port. onLineRedundancy(6) indicates that the ch is up, and it is the active link
OBJECT-TYPE    
  INTEGER unknown(1), notUsed(2), offLine(3), onLine(4), offLineRedundancy(5), onLineRedundancy(6)  

prtSAlrStatus 1.3.6.1.4.1.164.3.1.4.1.1.1.6
Indicates the alarm state in the port(ch) agent level. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

prtSMaskedAlrStat 1.3.6.1.4.1.164.3.1.4.1.1.1.7
Indicates the alarm state in the port(ch) agent level, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

prtSClearAlrCmd 1.3.6.1.4.1.164.3.1.4.1.1.1.8
Setting this attribute to on(3) enforces a clear operation of the alarm status events in the given port. The clear operation will not be applied for masked/inverted alarms.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSTestMask 1.3.6.1.4.1.164.3.1.4.1.1.1.9
This is a mask which indicates which tests from the 'prtSTstCmd' list are allowed for the requested port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- local-loop 1 remote-loop 2 loc-and-rem-main-loops 3 remote-analog-loop 4 remote-digital-loop 5 rem-loop-on-ext-unit 6 bert 7 tone-injection 8 dlci local-loop 9 all dlci local-loop 10 dlci remote-loop 11 all dlci remote-loop 12 bert-and-rem-loop-on-rem-unit 13 rem-loop-on-rem-unit 14 block 15 backward-tone-inject 16 llb 17 rlb 18 ft1Enable 21 lbbd 22 --for 2B+D lb1 23 --for B1 lb2 24 --for B2 llb-on-rem-unit 25 bert-on-rem-unit 26 bert-on-rem-and-llb-on-rem-unit 27 local-and-bert-on-rem-unit 28 local-loop-on-rem-unit 29 localBert 30 --towards IO ports test-per-TS 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
OBJECT-TYPE    
  Integer32  

prtSTstCmd 1.3.6.1.4.1.164.3.1.4.1.1.1.10
Setting this attribute to any of the above values will initiate a test on the specific port if the operation is legal. If the operation is not legal, the mux will ignore the operation. testPerTS(31) - when this test is selected, the selection of tests for each TS is done via the prtExPh1MlTsTest object. If a test time out is needed, the test will be set with a default timeout of 2 minutes until the user will set the parameter 'prtSTstDuration' to the required time out. If no time out is needed , the test will be set with infinite timeout until the user will set the parameter 'prtSTstDuration' to the required time out.
OBJECT-TYPE    
  INTEGER none(1), localLoop(2), remoteLoop(3), locAndRemMainLoops(4), remoteAnalogLoop(5), remoteDigitalLoop(6), remLoopOnExtUnit(7), bert(8), toneInjection(9), dlciLocalLoop(10), allDlciLocalLoop(11), dlciRemoteLoop(12), allDlciRemoteLoop(13), extInitLocalLoop(14), bertAndRemLoopOnRemUnit(15), remLoopOnRemUnit(16), block(17), backwardToneInject(18), llb(19), rlb(20), ft1Enable(21), lbbd(22), lb1(23), lb2(24), llbOnRemUnit(25), bertOnRemUnit(26), bertOnRemAndLlbOnRemUnit(27), localAndBertOnRemUnit(28), localLoopOnRemUnit(29), localBert(30), testPerTS(31)  

prtSTstDuration 1.3.6.1.4.1.164.3.1.4.1.1.1.11
This attribute indicates the maximum duration of executing a test on the specific port. This entry applies to all the test operations. The resolution will be a minute, and the maximum duration is limited to 30 minutes . A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtSTstCmd' parameter.
OBJECT-TYPE    
  Integer32  

prtSBertClrCmd 1.3.6.1.4.1.164.3.1.4.1.1.1.12
Setting this attribute initiates bert count clear operation. It is valid only when bert test is active on the specific port.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSBertTstRslt 1.3.6.1.4.1.164.3.1.4.1.1.1.13
This attribute indicates the number of Bit Error Rate indicated during the BERT operation. It is valid only when bert test is active on the specific port.
OBJECT-TYPE    
  Integer32  

prtSInterfaceType 1.3.6.1.4.1.164.3.1.4.1.1.1.14
This attribute indicates a unique HW interface type of the selected port.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

prtSParamStatus 1.3.6.1.4.1.164.3.1.4.1.1.1.15
This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For ACM external port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |_________| spare Alarm State Alarm State: according to bits 1,0: 00=NA ; 01=unused ; 10=Off ; 11=On - For HS-U/1 external port - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For MTML-2 external ports, MTML-E2 internal ports - 1 Octet : Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs/Bits) 1 = ON (BERT is running on this port OR on one of its TSs/Bits)
OBJECT-TYPE    
  OCTET STRING  

prtSAlrTable 1.3.6.1.4.1.164.3.1.4.1.2
The list of port agent alarms.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSAlrEntry

prtSAlrEntry 1.3.6.1.4.1.164.3.1.4.1.2.1
An entry in table.
OBJECT-TYPE    
  PrtSAlrEntry  

prtSAlrIdx 1.3.6.1.4.1.164.3.1.4.1.2.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive
OBJECT-TYPE    
  Integer32  

prtSAlrSltIdx 1.3.6.1.4.1.164.3.1.4.1.2.1.2
This attribute indicates a unique identifier of the slot where the card is inserted. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtSAlrPrtIdx 1.3.6.1.4.1.164.3.1.4.1.2.1.3
This attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a port which does not exist. Valid values: exPrt1 (1) .. exPrt16 (16) , inPrt1 (101) .. inPrt48 (148), IP Bundles.
OBJECT-TYPE    
  Integer32  

prtSAlrCodeDescription 1.3.6.1.4.1.164.3.1.4.1.2.1.4
This attribute is a full text description of the alarm. The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

prtSAlrCode 1.3.6.1.4.1.164.3.1.4.1.2.1.5
A code identifying the alarm of an entry in the alarm status table at port level.
OBJECT-TYPE    
  Integer32  

prtSAlrSeverity 1.3.6.1.4.1.164.3.1.4.1.2.1.6
The severity of the alarm.
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

prtSAlrState 1.3.6.1.4.1.164.3.1.4.1.2.1.7
State of the alarm.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlrCounter 1.3.6.1.4.1.164.3.1.4.1.2.1.8
A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
OBJECT-TYPE    
  Integer32  

prtSAlrMask 1.3.6.1.4.1.164.3.1.4.1.2.1.9
Alarm mask : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlrInvert 1.3.6.1.4.1.164.3.1.4.1.2.1.10
Alarm invert : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

statisPrtGen 1.3.6.1.4.1.164.3.1.4.1.3
OBJECT IDENTIFIER    

prtFrStatis 1.3.6.1.4.1.164.3.1.4.1.3.1
OBJECT IDENTIFIER    

prtFrStatisTable 1.3.6.1.4.1.164.3.1.4.1.3.1.1
This table is applicable only for an active port running an FR protocol .
OBJECT-TYPE    
  SEQUENCE OF  
    PrtFrStatisEntry

prtFrStatisEntry 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1
An entry in table.
OBJECT-TYPE    
  PrtFrStatisEntry  

prtFrStatisSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtFrStatisPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.2
This attribute indicates a unique port number.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtFrStatisInvIdx 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.3
The Interval of 15 min. for which the following statistics counters are applicable.
OBJECT-TYPE    
  INTEGER currentInv(1), last(2)  

prtFrTimeElapsed 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.4
The number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0.
OBJECT-TYPE    
  Integer32 0..899  

prtFrRxTotalFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.5
The total number of frames received by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrTxTotalFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.6
The total number of frames sent by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrRxTotalBytes 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.7
The total number of bytes received by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrTxTotalBytes 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.8
The total number of bytes sent by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrRxMngFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.9
The management number of frames received by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrTxMngFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.10
The management number of frames sent by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrRxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.11
The number of De frames received by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrTxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.12
The number of De frames sent by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrRxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.13
The number of De frames discarded due to congestion, received by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrTxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.14
The number of De frames discarded due to congestion, sent by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrRxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.15
All the frames discarded due to congestion, received by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrTxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.16
All the frames discarded due to congestion, sent by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtFrRxFecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.17
Number of frames received by this port during the selected interval, indicating forward congestion.
OBJECT-TYPE    
  Counter32  

prtFrTxFecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.18
Number of frames sent by this port during the selected interval, indicating forward congestion.
OBJECT-TYPE    
  Counter32  

prtFrRxBecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.19
Number of frames received by this port during the selected interval, indicating backward congestion.
OBJECT-TYPE    
  Counter32  

prtFrTxBecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.20
Number of frames sent by this port during the selected interval, indicating backward congestion.
OBJECT-TYPE    
  Counter32  

prtFrRxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.21
Number of data frames received by this port during the selected interval, exceeding the Burst Excess value.
OBJECT-TYPE    
  Counter32  

prtFrTxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.22
Number of data frames sent by this port during the selected interval, exceeding the Burst Excess value.
OBJECT-TYPE    
  Counter32  

prtFrRxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.23
Number of data frames received by this port during the selected interval, exceeding the Burst Committed value.
OBJECT-TYPE    
  Counter32  

prtFrTxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.24
Number of data frames sent by this port during the selected interval, exceeding the Burst Committed value.
OBJECT-TYPE    
  Counter32  

prtCrStatis 1.3.6.1.4.1.164.3.1.4.1.3.2
OBJECT IDENTIFIER    

prtCrStatisTable 1.3.6.1.4.1.164.3.1.4.1.3.2.1
This table is applicable only for an active port running a CR protocol .
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCrStatisEntry

prtCrStatisEntry 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1
An entry in table.
OBJECT-TYPE    
  PrtCrStatisEntry  

prtCrStatisSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtCrStatisPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.2
This attribute indicates a unique port number.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtCrStatisInvIdx 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.3
The Interval of 15 min. for which the following statistics counters are applicable.
OBJECT-TYPE    
  INTEGER currentInv(1), last(2)  

prtCrTimeElapsed 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.4
The number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0.
OBJECT-TYPE    
  Integer32 0..899  

prtCrRxTotalCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.5
The total number of cells received by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtCrTxTotalCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.6
The total number of cells sent by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtCrRxDataCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.7
The number of Data Cells received by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtCrTxDataCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.8
The number of Data Cells sent by this port during the selected interval.
OBJECT-TYPE    
  Counter32  

prtDlciStatis 1.3.6.1.4.1.164.3.1.4.1.3.3
OBJECT IDENTIFIER    

prtDlciStatisTable 1.3.6.1.4.1.164.3.1.4.1.3.3.1
This table is applicable only for an active port running an FR, FR+ or CR protocol, with valid DLCIs .
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDlciStatisEntry

prtDlciStatisEntry 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1
An entry in table.
OBJECT-TYPE    
  PrtDlciStatisEntry  

prtDlciSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtDlciPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.2
This attribute indicates a unique port number.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtDlciIdx 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.3
This attribute indicates a unique DLCI index for each valid DLCI (16..991).
OBJECT-TYPE    
  Integer32 1..991  

prtDlciRxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.4
The number of De frames received by this DLCI.
OBJECT-TYPE    
  Counter32  

prtDlciTxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.5
The number of De frames sent by this DLCI.
OBJECT-TYPE    
  Counter32  

prtDlciRxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.6
The number of De frames discarded due to congestion, received by this DLCI.
OBJECT-TYPE    
  Counter32  

prtDlciTxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.7
The number of De frames discarded due to congestion, sent by this DLCI.
OBJECT-TYPE    
  Counter32  

prtDlciRxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.8
All the frames discarded due to congestion, received by this DLCI.
OBJECT-TYPE    
  Counter32  

prtDlciTxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.9
All the frames discarded due to congestion, sent by this DLCI.
OBJECT-TYPE    
  Counter32  

prtDlciTxFecn 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.10
Number of frames sent by this DLCI, indicating forward congestion.
OBJECT-TYPE    
  Counter32  

prtDlciTxBecn 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.11
Number of frames sent by this DLCI, indicating backward congestion.
OBJECT-TYPE    
  Counter32  

prtDlciRxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.12
Number of data frames received by this DLCI, exceeding the Burst Excess value.
OBJECT-TYPE    
  Counter32  

prtDlciTxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.13
Number of data frames sent by this DLCI, exceeding the Burst Excess value.
OBJECT-TYPE    
  Counter32  

prtDlciRxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.14
Number of data frames received by this DLCI, exceeding the Burst Committed value.
OBJECT-TYPE    
  Counter32  

prtDlciTxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.15
Number of data frames sent by this DLCI, exceeding the Burst Committed value.
OBJECT-TYPE    
  Counter32  

prtT1Statis 1.3.6.1.4.1.164.3.1.4.1.3.4
OBJECT IDENTIFIER    

prtT1FdlMsgTable 1.3.6.1.4.1.164.3.1.4.1.3.4.1
This table is applicable for a T1 interface with 'esf' LineType .
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1FdlMsgEntry

prtT1FdlMsgEntry 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1
An entry in table.
OBJECT-TYPE    
  PrtT1FdlMsgEntry  

prtT1FdlMsgSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtT1FdlMsgPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.2
This attribute indicates a unique port number. MTML-1/T1 modules have just one external interface.
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtT1FdlMsgFdlTxRx 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.3
The Fdl tx/rx reference of the Fdl message.
OBJECT-TYPE    
  INTEGER tx(1), rx(2)  

prtT1FdlMsg 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.4
FDL message.
OBJECT-TYPE    
  OCTET STRING  

cnfgPrtGen 1.3.6.1.4.1.164.3.1.4.2
OBJECT IDENTIFIER    

prtExTsSplitTable 1.3.6.1.4.1.164.3.1.4.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry, except prtExTsBitTest that will be written directly to the Active Configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExTsSplitEntry

prtExTsSplitEntry 1.3.6.1.4.1.164.3.1.4.2.1.1
An entry in table.
OBJECT-TYPE    
  PrtExTsSplitEntry  

prtExTsCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtExTsSltIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExTsPrtIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.3
This attribute indicates a unique port number. Most ML cards have only one external interface. inPrt1 - for MTML-H/E1 cards. For other products' index see their specification.
OBJECT-TYPE    
  Integer32  

prtExTsIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.4
This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling.
OBJECT-TYPE    
  Integer32  

prtExTsBit 1.3.6.1.4.1.164.3.1.4.2.1.1.5
This attribute indicates a unique Bit within the time slot. The valid Bits are: 1..8.
OBJECT-TYPE    
  Integer32 1..8  

prtExTsIConSlot 1.3.6.1.4.1.164.3.1.4.2.1.1.6
This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units.
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExTsIConPrt 1.3.6.1.4.1.164.3.1.4.2.1.1.7
This attribute indicates the internally (In Mux) connected/routed port. For other products' index see their specification.
OBJECT-TYPE    
  Integer32  

prtExTsBitTest 1.3.6.1.4.1.164.3.1.4.2.1.1.8
This attribute indicates a test to be activated on the selected Bit. It is applicable only when prtExPh1MlTsTest=split(254). none - no test is applied for the selected Bit. notApplicable - when prtExPh1MlTsTest is NOT split(254).
OBJECT-TYPE    
  INTEGER none(1), remoteBert(8), localBert(30), notApplicable(255)  

prtExTsTxSignaling 1.3.6.1.4.1.164.3.1.4.2.1.1.9
Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It defines what is sent for the selected TS for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
OBJECT-TYPE    
  OCTET STRING  

prtExTsRxSignaling 1.3.6.1.4.1.164.3.1.4.2.1.1.10
Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It defines what is sent for the selected TS for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
OBJECT-TYPE    
  OCTET STRING  

prtCnfgAgenda 1.3.6.1.4.1.164.3.1.4.2.2
OBJECT IDENTIFIER    

prtAgendaBehaviourTable 1.3.6.1.4.1.164.3.1.4.2.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAgendaBehaviourEntry

prtAgendaBehaviourEntry 1.3.6.1.4.1.164.3.1.4.2.2.1.1
An entry in table.
OBJECT-TYPE    
  PrtAgendaBehaviourEntry  

prtAgendaBehaviourCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.2.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtAgendaBehaviourSltIdx 1.3.6.1.4.1.164.3.1.4.2.2.1.1.2
This parameter should be: - slot number for MX3000 - 255 = N/A for MX300/30.
OBJECT-TYPE    
  Integer32  

prtAgendaBehaviourPrtIdx 1.3.6.1.4.1.164.3.1.4.2.2.1.1.3
This parameter should be: - port number for MX300/30 - 100 = N/A for MX3000.
OBJECT-TYPE    
  Integer32  

prtAgendaBehaviourOnOff 1.3.6.1.4.1.164.3.1.4.2.2.1.1.4
Setting this command to on(3) enables the agenda function at module (3000) or port (300/30) level.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtCnfgAgendaTable 1.3.6.1.4.1.164.3.1.4.2.2.2
This table allows the user to schedule the time a session is active per week basis.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCnfgAgendaEntry

prtCnfgAgendaEntry 1.3.6.1.4.1.164.3.1.4.2.2.2.1
An entry in table.
OBJECT-TYPE    
  PrtCnfgAgendaEntry  

prtCnfgAgendaCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtCnfgAgendaSltIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.2
This attribute is equal to: -slot number for MX3000 -255 = N/A for MX300/30
OBJECT-TYPE    
  Integer32  

prtCnfgAgendaPrtIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.3
This attribute is equal to: - port number for MX300/30 - port number for MX3000. For example 1-4 in MHS-4 cards. - 100 = N/A for MX3000 when not used.
OBJECT-TYPE    
  Integer32  

prtCnfgAgendaDayIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.4
This attribute for which day of the week this row applies.
OBJECT-TYPE    
  INTEGER monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6), sunday(7)  

prtCnfgAgendaSesId 1.3.6.1.4.1.164.3.1.4.2.2.2.1.5
The user may define 4 different active intervals per day.
OBJECT-TYPE    
  Integer32 1..4  

prtCnfgAgendaFrom 1.3.6.1.4.1.164.3.1.4.2.2.2.1.6
Start from time interval in seconds.
OBJECT-TYPE    
  Integer32 0..86400  

prtCnfgAgendaTo 1.3.6.1.4.1.164.3.1.4.2.2.2.1.7
To time interval in seconds.
OBJECT-TYPE    
  Integer32 0..86400  

prtGenCnfgTable 1.3.6.1.4.1.164.3.1.4.2.3
This table allows the user to configure general port parameters.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenCnfgEntry

prtGenCnfgEntry 1.3.6.1.4.1.164.3.1.4.2.3.1
An entry in table.
OBJECT-TYPE    
  PrtGenCnfgEntry  

prtGenCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtGenCnfgSltIdx 1.3.6.1.4.1.164.3.1.4.2.3.1.2
This attribute indicates a unique slot position where the card is inserted.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtGenCnfgPrtIdx 1.3.6.1.4.1.164.3.1.4.2.3.1.3
This attribute indicates a unique external or internal port number. For MP: exPrt1 (1) .. exPrt16 (16) , notApplicable(100), inPrt1 (101) .. inPrt48 (148)
OBJECT-TYPE    
  Integer32  

prtGenCnfgLinkToSlot 1.3.6.1.4.1.164.3.1.4.2.3.1.4
This attribute indicates the slot of the ML card to which the IO port is mapped.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtGenCnfgLinkToPort 1.3.6.1.4.1.164.3.1.4.2.3.1.5
This attribute indicates the port in the prtGenCnfgLinkToSlot of the ML card to which the IO port is mapped. For MP: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , notApplicable (255)
OBJECT-TYPE    
  Integer32  

prtGenCnfgPortId 1.3.6.1.4.1.164.3.1.4.2.3.1.6
IO Port Id for V5.1 use. This object is applicable only for part of the PSTN and ISDN IO ports. Generally, 0 is a valid value. Nevertheless, for ports that do not support this object, the value will be: notApplicable= 0
OBJECT-TYPE    
  Integer32 0..16777215  

cmprPrtGen 1.3.6.1.4.1.164.3.1.4.3
OBJECT IDENTIFIER    

prtCmprTable 1.3.6.1.4.1.164.3.1.4.3.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCmprEntry

prtCmprEntry 1.3.6.1.4.1.164.3.1.4.3.1.1
An entry in table.
OBJECT-TYPE    
  PrtCmprEntry  

prtCmprTypIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.1
This attribute indicates the Type of the Compressed being referred.
OBJECT-TYPE    
  Integer32  

prtCmprCnfgIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.2
This attribute indicates the configuration to which the Compressed information is related.
OBJECT-TYPE    
  Integer32  

prtCmprVersion 1.3.6.1.4.1.164.3.1.4.3.1.1.3
This attribute indicates the version of the internal format of the Compressed data
OBJECT-TYPE    
  Integer32  

prtCmprSltIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.4
This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtCmprPrtIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.5
This attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt16 (16) , inPrt1 (101) .. inPrt48 (148).
OBJECT-TYPE    
  Integer32  

prtCmprObj 1.3.6.1.4.1.164.3.1.4.3.1.1.6
This attribute is the compressed information itself.
OBJECT-TYPE    
  OCTET STRING  

prtCmprStatisticObj 1.3.6.1.4.1.164.3.1.4.3.1.1.7
This attribute is the compressed statistics information itself.
OBJECT-TYPE    
  OCTET STRING  

prtDlciCmprTable 1.3.6.1.4.1.164.3.1.4.3.2
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDlciCmprEntry

prtDlciCmprEntry 1.3.6.1.4.1.164.3.1.4.3.2.1
An entry in table.
OBJECT-TYPE    
  PrtDlciCmprEntry  

prtDlciCmprCnfgIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.1
This attribute indicates the configuration to which the Compressed information is related.
OBJECT-TYPE    
  Integer32  

prtDlciCmprVersion 1.3.6.1.4.1.164.3.1.4.3.2.1.2
This attribute indicates the version of the internal format of the Compressed data
OBJECT-TYPE    
  Integer32  

prtDlciCmprSltIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.3
This attribute indicates a unique number of the slot position where the module is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtDlciCmprPrtIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.4
This attribute indicates a unique identifier of the port the compressed information relates to. All the values are valid.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

prtDlciCmprDlciIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.5
This attribute indicates a unique identifier of the Dlci the compressed information relates to. The values are between 16 - 991.
OBJECT-TYPE    
  Integer32  

prtDlciCmprObj 1.3.6.1.4.1.164.3.1.4.3.2.1.6
This attribute is the compressed information itself.
OBJECT-TYPE    
  OCTET STRING  

prtAlarmsCmprTable 1.3.6.1.4.1.164.3.1.4.3.3
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAlarmsCmprEntry

prtAlarmsCmprEntry 1.3.6.1.4.1.164.3.1.4.3.3.1
An entry in table.
OBJECT-TYPE    
  PrtAlarmsCmprEntry  

prtAlarmsCmprVersion 1.3.6.1.4.1.164.3.1.4.3.3.1.1
This attribute indicates the version of the internal format of the Compressed data
OBJECT-TYPE    
  Integer32  

prtAlarmsCmprAlarmSlot 1.3.6.1.4.1.164.3.1.4.3.3.1.2
This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For Stand-alone units, notApplicable(255) will appear.
OBJECT-TYPE    
  Integer32  

prtAlarmsCmprAlarmPort 1.3.6.1.4.1.164.3.1.4.3.3.1.3
This attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a non-existing port. IP Bundles are considered a port too, for this matter.
OBJECT-TYPE    
  Integer32  

prtAlarmsCmprAlarmIdx 1.3.6.1.4.1.164.3.1.4.3.3.1.4
A unique number to identify an entry in the alarm status table of the agent.
OBJECT-TYPE    
  Integer32  

prtAlarmsCmprObj 1.3.6.1.4.1.164.3.1.4.3.3.1.5
This attribute is the compressed information itself.
OBJECT-TYPE    
  OCTET STRING  

mapWanGen 1.3.6.1.4.1.164.3.1.5
OBJECT IDENTIFIER    

agnLinkMapTable 1.3.6.1.4.1.164.3.1.5.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    AgnLinkMapEntry

agnLinkMapEntry 1.3.6.1.4.1.164.3.1.5.1.1
An entry in table.
OBJECT-TYPE    
  AgnLinkMapEntry  

mapLinkId 1.3.6.1.4.1.164.3.1.5.1.1.1
A unique identifier of the link
OBJECT-TYPE    
  Integer32  

mapLinkSltIdx 1.3.6.1.4.1.164.3.1.5.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries clA(3), io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER noConnect(2), clA(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

mapLinkPrtIdx 1.3.6.1.4.1.164.3.1.5.1.1.3
This attribute indicates a unique port number.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

mapLinkStatus 1.3.6.1.4.1.164.3.1.5.1.1.4
This attribute indicates the status of the link between the two muxes
OBJECT-TYPE    
  INTEGER unknown(1), down(2), up(3)  

diverseIfWanGen 1.3.6.1.4.1.164.3.1.6
OBJECT IDENTIFIER    

ethIf 1.3.6.1.4.1.164.3.1.6.1
OBJECT IDENTIFIER    

ethIfTable 1.3.6.1.4.1.164.3.1.6.1.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfEntry

ethIfEntry 1.3.6.1.4.1.164.3.1.6.1.1.1
An entry in table.
OBJECT-TYPE    
  EthIfEntry  

ethIfIdx 1.3.6.1.4.1.164.3.1.6.1.1.1.1
A unique index of the ethernet interface/port.
OBJECT-TYPE    
  Integer32  

ethMode 1.3.6.1.4.1.164.3.1.6.1.1.1.2
This object indicates the Ethernet mode of operation.
OBJECT-TYPE    
  INTEGER halfDuplex(1), fullDuplex(2), notApplicable(255)  

ethBridgingMode 1.3.6.1.4.1.164.3.1.6.1.1.1.3
This object indicates the bridging mode of the Ethernet interface.
OBJECT-TYPE    
  INTEGER filtered(1), transparent(2)  

ethEncapsulationCRCMode 1.3.6.1.4.1.164.3.1.6.1.1.1.4
This object define the encapsulation type requested for the Ethernet interface. It indicates if we transfer the Ethernet frame to the other side with or without the CRC.
OBJECT-TYPE    
  INTEGER notApplicable(1), withCRC(2), withoutCRC(3)  

ethBackPressure 1.3.6.1.4.1.164.3.1.6.1.1.1.5
This parameter defines whether to enable or disable Back pressure. Back Pressure is a flow control parameter.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ethLimit4 1.3.6.1.4.1.164.3.1.6.1.1.1.6
This parameter determine the Back off algorithm mode. Every 4 following collisions the Framer will be thrown out (4 times more than usuall).
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ethSkipInitReset 1.3.6.1.4.1.164.3.1.6.1.1.1.7
This parameter defines whether read status on reset.
OBJECT-TYPE    
  INTEGER notApplicable(1), notSkip(2), skip(3)  

ethMulticastBlock 1.3.6.1.4.1.164.3.1.6.1.1.1.8
This parameter defines whether to send multicast message to WAN from LAN or not.
OBJECT-TYPE    
  INTEGER notApplicable(1), unBlock(2), block(3)  

ethBroadcastBlock 1.3.6.1.4.1.164.3.1.6.1.1.1.9
This parameter defines whether to send broadcast message to WAN from LAN or not.
OBJECT-TYPE    
  INTEGER notApplicable(1), unBlock(2), block(3)  

ethSpeed 1.3.6.1.4.1.164.3.1.6.1.1.1.10
This parameter defines the line speed.
OBJECT-TYPE    
  INTEGER notApplicable(1), s10Mbps(2), s100Mbps(3)  

ethIfPerformance 1.3.6.1.4.1.164.3.1.6.1.2
OBJECT IDENTIFIER    

ethIfCurrentTable 1.3.6.1.4.1.164.3.1.6.1.2.1
The Ethernet Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfCurrentEntry

ethIfCurrentEntry 1.3.6.1.4.1.164.3.1.6.1.2.1.1
An entry in the Ethernet Current table.
OBJECT-TYPE    
  EthIfCurrentEntry  

ethIfCurrentIndex 1.3.6.1.4.1.164.3.1.6.1.2.1.1.1
The index of the Ethernet interface. It may be ifIndex.
OBJECT-TYPE    
  Integer32  

ethIfCurrentStatus 1.3.6.1.4.1.164.3.1.6.1.2.1.1.2
The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

ethIfCurrentInFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.3
The counter associated with the number of received frames, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentInOctets 1.3.6.1.4.1.164.3.1.6.1.2.1.1.4
The counter associated with the number of received octets, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentAlignmentErrors 1.3.6.1.4.1.164.3.1.6.1.2.1.1.5
The counter associated with the number of received frames, which are not complete (The result of dividing the number of bits by 8 is not an Integer), encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentFCSErrors 1.3.6.1.4.1.164.3.1.6.1.2.1.1.6
The counter associated with the number of received frames that didn't pass the FCS test, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentLengthError 1.3.6.1.4.1.164.3.1.6.1.2.1.1.7
The counter associated with the number of received frames with length error, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOutFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.8
The counter associated with the number of transmitted frames, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOutOctets 1.3.6.1.4.1.164.3.1.6.1.2.1.1.9
The counter associated with the number of transmitted octets, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentSingleCollisionFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.10
The counter associated with the number of successfully transmitted frames for which transmission was inhibited by exactly one collision, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentMultipleCollisionFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.11
The counter associated with the number of successfully transmitted frames for which transmission was inhibited by more than one collision, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentDeferredTransmissions 1.3.6.1.4.1.164.3.1.6.1.2.1.1.12
The counter associated with the number of transmitted frames for which the first transmission attempt was delayed due to a busy media, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentLateCollisions 1.3.6.1.4.1.164.3.1.6.1.2.1.1.13
The counter associated with the number of times that a collision was detected later than the first 64 bytes of the frame, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfCurrentCarrierSenseErrors 1.3.6.1.4.1.164.3.1.6.1.2.1.1.14
The counter associated with the number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame, encountered by the Ethernet interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalTable 1.3.6.1.4.1.164.3.1.6.1.2.2
The Ethernet Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfIntervalEntry

ethIfIntervalEntry 1.3.6.1.4.1.164.3.1.6.1.2.2.1
An entry in the Ethernet Interval table.
OBJECT-TYPE    
  EthIfIntervalEntry  

ethIfIntervalIndex 1.3.6.1.4.1.164.3.1.6.1.2.2.1.1
The index of the Ethernet interface. It may be ifIndex.
OBJECT-TYPE    
  Integer32  

ethIfIntervalNumber 1.3.6.1.4.1.164.3.1.6.1.2.2.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist).
OBJECT-TYPE    
  Integer32 1..96  

ethIfIntervalStatus 1.3.6.1.4.1.164.3.1.6.1.2.2.1.3
The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

ethIfIntervalInFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.4
The counter associated with the number of received frames, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalInOctets 1.3.6.1.4.1.164.3.1.6.1.2.2.1.5
The counter associated with the number of received octets, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalAlignmentErrors 1.3.6.1.4.1.164.3.1.6.1.2.2.1.6
The counter associated with the number of received frames, which are not complete (The result of dividing the number of bits by 8 is not an Integer), encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalFCSErrors 1.3.6.1.4.1.164.3.1.6.1.2.2.1.7
The counter associated with the number of received frames that didn't pass the FCS test, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalLengthError 1.3.6.1.4.1.164.3.1.6.1.2.2.1.8
The counter associated with the number of received frames with length error, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOutFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.9
The counter associated with the number of transmitted frames, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOutOctets 1.3.6.1.4.1.164.3.1.6.1.2.2.1.10
The counter associated with the number of transmitted octets, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalSingleCollisionFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.11
The counter associated with the number of successfully transmitted frames for which transmission was inhibited by exactly one collision, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalMultipleCollisionFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.12
The counter associated with the number of successfully transmitted frames for which transmission was inhibited by more than one collision, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalDeferredTransmissions 1.3.6.1.4.1.164.3.1.6.1.2.2.1.13
The counter associated with the number of transmitted frames for which the first transmission attempt was delayed due to a busy media, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalLateCollisions 1.3.6.1.4.1.164.3.1.6.1.2.2.1.14
The counter associated with the number of times that a collision was detected later than the first 64 bytes of the frame, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

ethIfIntervalCarrierSenseErrors 1.3.6.1.4.1.164.3.1.6.1.2.2.1.15
The counter associated with the number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

muxHub 1.3.6.1.4.1.164.3.2
OBJECT IDENTIFIER    

muxHubEvents 1.3.6.1.4.1.164.3.2.0
The events for .
OBJECT-IDENTITY    

alarmsTrap 1.3.6.1.4.1.164.3.2.0.1
This trap is sent whenever alarm occurs in the agent.
NOTIFICATION-TYPE    
  alrBufDescription  

sanityTrap 1.3.6.1.4.1.164.3.2.0.2
This trap is sent after a data base update. It returns the sanity result status and the configuration no. checked. If the result is of Flip DB Sanity Check, the configuration no. sent will be 0. If the result is of Variant Sanity Check, the configuration no. sent will be 100.
NOTIFICATION-TYPE    
  agnSSanityCheckStatus  
  agnCSaveCnfgIdxCmd  

cnfgFlipTrap 1.3.6.1.4.1.164.3.2.0.3
This trap is sent upon change of the active Configuration DB. Attached, is the new active Configuration no.
NOTIFICATION-TYPE    
  agnSActiveCnfg  

flipDbChangeTrap 1.3.6.1.4.1.164.3.2.0.4
This trap is sent upon change of the active Flip tables (Flip DB).
NOTIFICATION-TYPE    

statusChangedTrap 1.3.6.1.4.1.164.3.2.0.5
This trap is sent upon any change of the LEDs status.
NOTIFICATION-TYPE    
  agnLed  

agnMux 1.3.6.1.4.1.164.3.2.1
OBJECT IDENTIFIER    

mdlMux 1.3.6.1.4.1.164.3.2.2
OBJECT IDENTIFIER    

cnfgMdlMux 1.3.6.1.4.1.164.3.2.2.1
OBJECT IDENTIFIER    

mdlPbxFramerCnfg 1.3.6.1.4.1.164.3.2.2.1.1
OBJECT IDENTIFIER    

mdlPbxFramerCnfgTable 1.3.6.1.4.1.164.3.2.2.1.1.1
This table contains parameters relevant to a module belonging to a digital voice system, except mdlPbxFraEnhEcho which is relevant also for analog cards.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlPbxFramerCnfgEntry

mdlPbxFramerCnfgEntry 1.3.6.1.4.1.164.3.2.2.1.1.1.1
An entry in table.
OBJECT-TYPE    
  MdlPbxFramerCnfgEntry  

mdlPbxFraCnfgIdx 1.3.6.1.4.1.164.3.2.2.1.1.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32  

mdlPbxFraSltIdx 1.3.6.1.4.1.164.3.2.2.1.1.1.1.2
The slot relevant to this module.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlPbxFraEnhEcho 1.3.6.1.4.1.164.3.2.2.1.1.1.1.3
Refers to external ports of an analogue module and to the internal ports of the other mvc4 types of modules. ms16(3) means that the four voice ports have enhanced echo of 16ms. ms32(4) means that the two first ports have enhanced echo of 32 ms while the last two ports have no enhanced echo.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), ms16(3), ms32(4)  

mdlPbxFraTSGroupAss 1.3.6.1.4.1.164.3.2.2.1.1.1.1.4
In case of T1 modules: group1=(1,2,3,4), ...., group6=(21,22,23,24) while in case of E1 modules: - If prtExPh1MlLineType=g732sE1 or g732sE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,17), group5=(18,19,20,21),...,group7=(26,27,28,29) group8=(30,31). - If prtExPh1MlLineType=g732nE1 or g732nE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,16), group5=(17,18,19,20),...,group7=(25,26,27,28) group8=(29,30,31).
OBJECT-TYPE    
  INTEGER group1(1), group2(2), group3(3), group4(4), group5(5), group6(6), group7(7), group8(8), notApplicable(255)  

mdlPbxFraSignalMode 1.3.6.1.4.1.164.3.2.2.1.1.1.1.5
Refers to the signaling mode of the Framer module. tieTrunk(2), tieInvert(3), casTrans(4) are standard coding of the signaling protocol. casTrans(4) is Channel Associated Signaling (the signaling is within the channels time slot). ccsTrans(6) is Transparent Common Channel Signaling (the signaling is not within the channels time slot - a TS for signaling is used). userDefined(5) allows the user to define the signaling protocol he wants. In this case, the next two MIB fields are relevant.
OBJECT-TYPE    
  INTEGER notApplicable(1), tieTrunk(2), tieInvert(3), casTrans(4), userDefined(5), ccsTrans(6), noSignaling(7)  

mdlPbxFraSignalVector 1.3.6.1.4.1.164.3.2.2.1.1.1.1.6
In the case of mdlPbxFraSignalMode = userDefined(5), this field defines the A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote In conjunction with the Mask, mdlPbxFraSignalMask, it is possible to compute the signal mode.
OBJECT-TYPE    
  OCTET STRING  

mdlPbxFraSignalMask 1.3.6.1.4.1.164.3.2.2.1.1.1.1.7
In the case of mdlPbxFraSignalMode = userDefined(5), this field defines the 'don't care' A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote.
OBJECT-TYPE    
  OCTET STRING  

mdlPbxFraFramerSlot 1.3.6.1.4.1.164.3.2.2.1.1.1.1.8
Slot where is sitting the Framer.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlPbxFraSignaling 1.3.6.1.4.1.164.3.2.2.1.1.1.1.9
Signaling - describes the way the signaling ABCD bits pass from the local extension to the remote extension and vice-versa. endToEnd = the signaling ABCD bits pass without change from local to remote extension. localTermination = the signaling ABCD bits received from the local extension are translated to different ON Hook/OFF Hook bit values and then passed to remote extension. This is relevant when the Local and Remote ON Hook/OFF Hook values are different.
OBJECT-TYPE    
  INTEGER notApplicable(1), endToEnd(2), localTermination(3)  

mdlPbxFraTransSigTs 1.3.6.1.4.1.164.3.2.2.1.1.1.1.10
This is the Time Slot that is used for Transparent CCS signaling. The values of this TS are 1-24 for T1 & 1-31 for E1. The default for E1 is 16 & for T1 it is 24. If no signaling is used then the TS should be 255 (None).
OBJECT-TYPE    
  Integer32  

prtMux 1.3.6.1.4.1.164.3.2.3
OBJECT IDENTIFIER    

statPrtMux 1.3.6.1.4.1.164.3.2.3.1
OBJECT IDENTIFIER    

prtSExHsfStatTable 1.3.6.1.4.1.164.3.2.3.1.6
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSExHsfStatEntry

prtSExHsfStatEntry 1.3.6.1.4.1.164.3.2.3.1.6.1
An entry in table.
OBJECT-TYPE    
  PrtSExHsfStatEntry  

prtSExHsfSltIdx 1.3.6.1.4.1.164.3.2.3.1.6.1.1
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtSExHsfPrtIdx 1.3.6.1.4.1.164.3.2.3.1.6.1.2
This attribute indicates a unique port number.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtSExHsfInterfaceTyp 1.3.6.1.4.1.164.3.2.3.1.6.1.3
This attribute indicates a unique interface type of a selected port.
OBJECT-TYPE    
  INTEGER unknown(1), v35(2), rs422(3)  

prtSExHsfRts 1.3.6.1.4.1.164.3.2.3.1.6.1.4
This attribute indicates a unique RTS control signal state.
OBJECT-TYPE    
  INTEGER unknown(1), notActive(2), active(3)  

cnfgPrtMux 1.3.6.1.4.1.164.3.2.3.2
OBJECT IDENTIFIER    

prtClCnfg 1.3.6.1.4.1.164.3.2.3.2.1
OBJECT IDENTIFIER    

prtExClCnfgTable 1.3.6.1.4.1.164.3.2.3.2.1.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExClCnfgEntry

prtExClCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.1.1.1
All the entries at this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  PrtExClCnfgEntry  

prtExClCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.1.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtExClSltIdx 1.3.6.1.4.1.164.3.2.3.2.1.1.1.2
This attribute indicates a unique slot position where the card is inserted. Because the second Cl is only for redundancy, all the parameters are identical in the two modules, i.e. change of any parameter in one module will change automatically the value of the other module.. In the ?004 Unit the entry clB(4) is not valid.
OBJECT-TYPE    
  INTEGER clA(3), clB(4), notApplicable(255)  

prtExClPrtIdx 1.3.6.1.4.1.164.3.2.3.2.1.1.1.3
This attribute indicates a unique port number.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2)  

prtExClUsage 1.3.6.1.4.1.164.3.2.3.2.1.1.1.4
This attribute indicates what is the usage of the port.
OBJECT-TYPE    
  INTEGER unknown(1), noUse(2), nmsSlip(3), nmsPpp(4), muxSlip(5), muxPpp(6), terminal(7)  

prtExClRate 1.3.6.1.4.1.164.3.2.3.2.1.1.1.5
This attribute indicates the operation rate of the port.
OBJECT-TYPE    
  INTEGER r300Bps(1), r1200Bps(2), r2400Bps(3), r4800Bps(4), r9600Bps(5), r19200Bps(6), r38400Bps(7), r57600Bps(8), r115200Bps(9)  

prtExClDataBits 1.3.6.1.4.1.164.3.2.3.2.1.1.1.6
This attribute indicates the number of data bits in async frame
OBJECT-TYPE    
  INTEGER dataBits7Bits(1), dataBits8Bits(2)  

prtExClParity 1.3.6.1.4.1.164.3.2.3.2.1.1.1.7
This attribute indicates if the parity operation mode in async frame
OBJECT-TYPE    
  INTEGER odd(1), even(2), none(3)  

prtExClStopBits 1.3.6.1.4.1.164.3.2.3.2.1.1.1.8
This attribute indicates the minimum number of stop bits in the tx async frame
OBJECT-TYPE    
  INTEGER stopBits1Bit(1), stopBits1dot5Bits(2), stopBits2Bits(3)  

prtExClRoutingProtocol 1.3.6.1.4.1.164.3.2.3.2.1.1.1.9
This attribute indicates the routing protocol of the port. When prtExClUsage is nmsSlip or nmsPpp - all values are applicable . Else - only 'none' is applicable.
OBJECT-TYPE    
  INTEGER none(1), rip2(2)  

prtExClEnabled 1.3.6.1.4.1.164.3.2.3.2.1.1.1.10
This attribute indicates if Ethernet port of CL is enabled or not for management. It is applicable only on the ETH port of the CL, when the MP includes an ML-IP card. disabled - will happen when there is Inband Management via the ML-IP link/s enabled - will happen when ML-IP link/s is not used for Inband Management, but CL's ETH port .
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtPh1MlCnfg 1.3.6.1.4.1.164.3.2.3.2.2
OBJECT IDENTIFIER    

prtExPh1MlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPh1MlCnfgEntry

prtExPh1MlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.2.1.1
An entry in table.
OBJECT-TYPE    
  PrtExPh1MlCnfgEntry  

prtExPh1MlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtExPh1MlSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.1.1.2
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid. For the Vmux2100 Main Board notApplicable (1) is used.
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.1.1.3
This attribute indicates a unique port number. MTML-1/E1 and MTML-1/T1 cards have only one external interface. inPrt1, inPrt2 - for MTML-H/2E1 and HSH cards. inPrt1..inPrt4 - for MTML-E2 cards. exPrt2..exPrt4 - for MTML-4 cards and others.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104)  

prtExPh1MlConnect 1.3.6.1.4.1.164.3.2.3.2.2.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the card considerations because it may indicate that the module has only one physical interface.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPh1MlLineType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.5
This attribute is the line type parameter for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for the MPH.1/T1 E1 line code parameters for the MPH.1/E1. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7)
OBJECT-TYPE    
  INTEGER esfT1(2), sfT1(3), g732nE1(4), g732nE1CRC(5), g732sE1(6), g732sE1CRC(7)  

prtExPh1MlLineCode 1.3.6.1.4.1.164.3.2.3.2.2.1.1.6
This attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for MPH.1/T1 E1 line code parameters for MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
OBJECT-TYPE    
  INTEGER b7T1(1), b8zsT1(2), transT1(3), hdb3E1(4), notApplicable(255)  

prtExPh1MlLineLen 1.3.6.1.4.1.164.3.2.3.2.2.1.1.7
This attribute is the line length parameter used only for T1/DSU interfaces. lenXXXpXXXft = len-XXX-XXXft.
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), lenFcc68(7), notApplicable(255)  

prtExPh1MlRestoreTime 1.3.6.1.4.1.164.3.2.3.2.2.1.1.8
The time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface.
OBJECT-TYPE    
  INTEGER restoreT1secFast(2), restoreT10sec62411(3), ccittE1(4)  

prtExPh1MlTxGain 1.3.6.1.4.1.164.3.2.3.2.2.1.1.9
This attribute is the tx gain parameter used only for T1/CSU interfaces.
OBJECT-TYPE    
  INTEGER notApplicable(1), txGain0db(2), txGain7dot5db(3), txGain15db(4), txGain22dot5db(5)  

prtExPh1MlRxSensitivity 1.3.6.1.4.1.164.3.2.3.2.2.1.1.10
This attribute is the rx line sensitivity parameter. low26dBm, high36dBm - applicable for T1-CSU shortHaul, longHaul - applicable for MTML-4 cards.
OBJECT-TYPE    
  INTEGER notApplicable(1), low26dBm(2), high36dBm(3), shortHaul(4), longHaul(5)  

prtExPh1MlIdleCode 1.3.6.1.4.1.164.3.2.3.2.2.1.1.11
Determines the code for transmission in empty time slots. Type value(00-FFH), Excluding 0H,8H,10H,12H,21H,24H,42H,49H, 84H,92H
OBJECT-TYPE    
  Integer32  

prtExPh1MlTdmTrunk 1.3.6.1.4.1.164.3.2.3.2.2.1.1.12
This attribute indicates whether the port is used to transfer TDM cards data and through which Bus.
OBJECT-TYPE    
  INTEGER linkA(1), linkB(2), none(3), notApplicable(255)  

prtExPh1MlClkMode 1.3.6.1.4.1.164.3.2.3.2.2.1.1.13
Defines the clock operation mode of the T1/E1 interface. Ports that are connected to the TDM Buses must be in nodalTiming(3) clock mode.
OBJECT-TYPE    
  INTEGER internalLocal(1), loopBackLocal(2), nodalTiming(3)  

prtExPh1MlMfClkSrcSlt 1.3.6.1.4.1.164.3.2.3.2.2.1.1.14
This attribute indicates whether the port Tx multiframe is synchronized with Rx multiframe of another port and the slot position of that port. This operation is required in order to bypass signaling of PCM voice channels. Its value is always local(2) when the port isn't connected to any TDM bus. When it's value is local(2) there is no meaning to 'prtExPh1MlMfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlMfClkSrcPrt 1.3.6.1.4.1.164.3.2.3.2.2.1.1.15
A unique number to identify a port position in the mux. It has no effect when the prtExPh1MlMfClkSrcSlt selected is Local. inPrt1 - for MTML-H/E1 cards.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), inPrt1(101), notApplicable(255)  

prtExPh1MlFdlType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.16
A unique number to identify the side of the FDL operation. Normal: 'response' for the user side and 'command' for the PTT side. Applicable only when working with ESF-T1 link
OBJECT-TYPE    
  INTEGER notApplicable(1), response(2), command(3)  

prtExPh1MlInbandMng 1.3.6.1.4.1.164.3.2.3.2.2.1.1.17
A unique number to identify an Inband management over the link.
OBJECT-TYPE    
  INTEGER off(2), fdlOrTs0(3), dedicatedTs(4), dedicatedPpp(5), dedicatedFr(6), notApplicable(255)  

prtExPh1MlInbandMngRate 1.3.6.1.4.1.164.3.2.3.2.2.1.1.18
A unique number to identify the rate of the Inband management. E1 port - it is not applicable when prtExPh1MlInbandMng selected is off. T1 port - it is not applicable when prtExPh1MlInbandMng selected is off OR fdlOrTs0.
OBJECT-TYPE    
  INTEGER notApplicable(1), r4k(2), r8k(3), r12k(4), r16k(5), r32k(6), r64k(7), r20k(8)  

prtExPh1MlRedundType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.19
This object determines the ML redundancy type: none - no ML redundacy dualCableAIS - each ML card is connected by a separate dualCableParallelTx cable to the other MUX (two cables connect two MUXes). There are two types of dual redundancy. yCable - Y cable is connected to both ML cards (one cable connects two MUXes). Default=none When only one ML card exists, the type can be only 'none'. The value should be the same for both ML slots.
OBJECT-TYPE    
  INTEGER none(1), dualCableAIS(2), yCable(3), dualCableParallelTx(4)  

prtExPh1MlRedundSlot 1.3.6.1.4.1.164.3.2.3.2.2.1.1.20
This object indicates the slot containing the redundacy ML card, coupled with the current ML (prtExPh1MlSltIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. In the ?004 Unit the entries io6(10)..io12(16) are not valid When value is not 'none', it should be mutual to the redundant ML slot.
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlRedundPort 1.3.6.1.4.1.164.3.2.3.2.2.1.1.21
This object indicates the redundacy ML port, coupled with the current ML port (prtExPh1MlPrtIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. When value is not 'none', it should be mutual to the redundant ML port. inPrt1 - for MTML-H/E1 cards. inPrt1..inPrt4 - for MTML-E2 cards. exPrt2..exPrt4 - for MTML-4 cards.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), notApplicable(255)  

prtExPh1MlRedundRecTime 1.3.6.1.4.1.164.3.2.3.2.2.1.1.22
Redundancy Recovery Time (sec). After switching the ML card to the current (prtExPh1MlSltIdx), the next ML switch can be performed only after a minimum time, indicated by this object.
OBJECT-TYPE    
  Integer32 1..99  

prtExPh1MlInbandMngRoutProt 1.3.6.1.4.1.164.3.2.3.2.2.1.1.23
This attribute indicates the Inband Mng routing protocol of the port.
OBJECT-TYPE    
  INTEGER none(1), rip2(2), proprietary(3)  

prtExPh1MlIfType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.24
Interface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values.
OBJECT-TYPE    
  INTEGER notApplicable(1), csu(2), dsu(3), ltu(4)  

prtExPh1MlMultiplier 1.3.6.1.4.1.164.3.2.3.2.2.1.1.25
The data rate of each TS. The multiplier values can be 56 kbps or 64 kbps.
OBJECT-TYPE    
  INTEGER notApplicable(1), br56(2), br64(3)  

prtExPh1MlSupportedTS 1.3.6.1.4.1.164.3.2.3.2.2.1.1.26
Number of Supported Time Slots by the agent. For Vmux-110 there is HW that supports less than 31/24 Time Slots for the E1/T1 port.
OBJECT-TYPE    
  INTEGER  

prtExPh1MlTsTable 1.3.6.1.4.1.164.3.2.3.2.2.2
The write operation into the Table Objects is valid only to the TmpCnfg entry, except prtExPh1MlTsTest that will be written directly to the Active Configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPh1MlTsEntry

prtExPh1MlTsEntry 1.3.6.1.4.1.164.3.2.3.2.2.2.1
An entry in table.
OBJECT-TYPE    
  PrtExPh1MlTsEntry  

prtExPh1MlTsCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtExPh1MlTsSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid. For the Vmux2100 Main Board notApplicable (255) is used.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPh1MlTsPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.3
This attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have only one external interface. exPrt2 - for ME1-2, MT1-2 and mhsPri cards. exPrt3, exPrt4 - for mhsPri cards. inPrt1 - for MTML-H/E1 cards.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101)  

prtExPh1MlTsIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.4
This attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
OBJECT-TYPE    
  Integer32  

prtExPh1MlTsIConSlot 1.3.6.1.4.1.164.3.2.3.2.2.2.1.5
This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS).
OBJECT-TYPE    
  INTEGER unknown(1), noConnect(2), split(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPh1MlTsIConPrt 1.3.6.1.4.1.164.3.2.3.2.2.2.1.6
This attribute indicates the internally (In Mux) connected/routed port. For MP, the values will be: { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) }
OBJECT-TYPE    
  Integer32  

prtExPh1MlTsIConTs 1.3.6.1.4.1.164.3.2.3.2.2.2.1.7
This attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated to multiframe synchronization and voice signaling.
OBJECT-TYPE    
  Integer32  

prtExPh1MlTsExt 1.3.6.1.4.1.164.3.2.3.2.2.2.1.8
A pointer to an extension of this table: prtExTsSplitTable. - If prtExPh1MlTsIConSlot='split', its value should be set to the OBJECT IDENTIFIER of the prtExTsSplitTable, with its relevant CnfgIdx, SltIdx, PrtIdx, TsIdx and 1st TsBit. - If prtExPh1MlTsIConSlot is not 'split', its value should be set to the OBJECT IDENTIFIER { 0 0 }.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

prtExPh1MlTsTest 1.3.6.1.4.1.164.3.2.3.2.2.2.1.9
This attribute indicates a test to be activated on the selected TS. It is applicable only when prtSTstCmd=testPerTS(31). notApplicable - when prtSTstCmd is NOT testPerTS(31). none - no test is applied for the selected TS. split - when the tests are per Bit of the selected TS.
OBJECT-TYPE    
  INTEGER none(1), localLoop(2), remoteLoop(3), remoteBert(8), localToneInjection(9), remoteToneInjection(18), localBert(30), split(254), notApplicable(255)  

prtExPh1MlTsType 1.3.6.1.4.1.164.3.2.3.2.2.2.1.10
The Time Slot Type.
OBJECT-TYPE    
  INTEGER noConnect(2), data(3), voice(4), cas(5), notApplicable(255)  

prtExPh1MlTsBundle 1.3.6.1.4.1.164.3.2.3.2.2.2.1.11
The number of the bundle containing this Time Slot. If no bundle exists for this TS or the bundle number is irrelevant, the value will be 0.
OBJECT-TYPE    
  INTEGER  

prtExPh1MlTsTestDuration 1.3.6.1.4.1.164.3.2.3.2.2.2.1.12
This attribute indicates the maximum duration of executing a test on the specific TS. This entry applies to all the test operations. For the Vmux2100 the values are: 0 - 60 seconds. A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtExPh1MlTsTest' parameter.
OBJECT-TYPE    
  Integer32  

prtInPh1MlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.2.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInPh1MlCnfgEntry

prtInPh1MlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.2.3.1
An entry in table.
OBJECT-TYPE    
  PrtInPh1MlCnfgEntry  

prtInPh1MlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtInPh1MlSltType 1.3.6.1.4.1.164.3.2.3.2.2.3.1.2
This attribute indicates a unique slot position where the card is inserted. For ISDN BRI port of MX300/30: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io12(16) are not valid
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtInPh1MlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.3.1.3
This attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have three internal interfaces. MX3000 modules may have up to 50 internal ports.
OBJECT-TYPE    
  Integer32  

prtInPh1MlConnect 1.3.6.1.4.1.164.3.2.3.2.2.3.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInPh1MlRate 1.3.6.1.4.1.164.3.2.3.2.2.3.1.5
This attribute indicates the port speed.
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17), r9x64eq576Kbps(18), r10x56eq560Kbps(19), r10x64eq640Kbps(20), r11x56eq616Kbps(21), r11x64eq704Kbps(22), r12x56eq672Kbps(23), r12x64eq768Kbps(24), r13x56eq728Kbps(25), r13x64eq832Kbps(26), r14x56eq784Kbps(27), r14x64eq896Kbps(28), r15x56eq840Kbps(29), r15x64eq960Kbps(30), r16x56eq896Kbps(31), r16x64eq1024Kbps(32), r17x56eq952Kbps(33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), noRate(100)  

prtInPh1MlProtocol 1.3.6.1.4.1.164.3.2.3.2.2.3.1.6
This attribute indicates the applied protocol.
OBJECT-TYPE    
  INTEGER fr(1), frPlus(2), pCellRelay(3), hdlcSdlc(4), transparentHdlc(5)  

prtInPh1MlConnectionTyp 1.3.6.1.4.1.164.3.2.3.2.2.3.1.7
This attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management operation (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetNotMana - indicates network internal line, but the remote mux is not managed by the nms. User - User to Network Interface. OtherNet - Network To Network Interfce. PubNet - Access Mux To PubNet Interface.
OBJECT-TYPE    
  INTEGER sameNetManaged(1), sameNetNotMana(2), user(3), otherNet(4), pubNet(5), notApplicable(255)  

prtInPh1MlCongResponse 1.3.6.1.4.1.164.3.2.3.2.2.3.1.8
This attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/receive becn to/from the network). no - do nothing FlowControl - translate the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done in both directions.
OBJECT-TYPE    
  INTEGER no(2), flowControl(3)  

prtInPh1MlCongLevel 1.3.6.1.4.1.164.3.2.3.2.2.3.1.9
This attribute indicates the level of delayed data in precents of the total available dynamic memory, for which the port will start to operate . The resolution of the parameter is 5 percent. Valid values: 10..70, 255. 255=notApplicable.
OBJECT-TYPE    
  Integer32  

prtInPh1MlTc 1.3.6.1.4.1.164.3.2.3.2.2.3.1.10
This attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports in the specific card. 255=notApplicable.
OBJECT-TYPE    
  INTEGER tc1sec(1), tc2sec(2), tc3sec(3), tc4sec(4), notApplicable(255)  

prtInPh1MlFlowControl 1.3.6.1.4.1.164.3.2.3.2.2.3.1.11
This attribute indicates the required flow control betweeen the port and the remote equipment.
OBJECT-TYPE    
  INTEGER none(2), fecnBecn(3)  

prtInPh1MlSegment 1.3.6.1.4.1.164.3.2.3.2.2.3.1.12
This object is the Segmentation in Bytes. In protocol FR+, ISDN internals, MX 30/300 the segmentation is: 50 (2) ,158 (3) ,266 (4) ,376 (5), 484 (6) In MX 3000/4: For protocol FR+ (internal ISDN ports of MHS.S, MHS.U, MHS.E1, MHS.T1 cards) segmentation values are: 236 (7),472 (8), 708 (9), 944 (10) ,1180 (11)
OBJECT-TYPE    
  INTEGER notApplicable(1), s36Byte(2), s150Byte(3), s264Byte(4), s378Byte(5), s492Byte(6), s236Byte(7), s472Byte(8), s708Byte(9), s944Byte(10), s1180Byte(11)  

prtInPh1MlFrMngProt 1.3.6.1.4.1.164.3.2.3.2.2.3.1.13
This object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtInPh1MlConnectionTyp = sameNetManaged, this object will be RO (internally determined).
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), lmi(3), ansiT1(4), annexA(5)  

prtInPh1MlEnqPeriod 1.3.6.1.4.1.164.3.2.3.2.2.3.1.14
This object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
OBJECT-TYPE    
  Integer32 0..30  

prtInPh1MlFullRptPeriod 1.3.6.1.4.1.164.3.2.3.2.2.3.1.15
This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite (never sent). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
OBJECT-TYPE    
  Integer32 0..255  

prtInPh1MlFrWindowSize 1.3.6.1.4.1.164.3.2.3.2.2.3.1.16
This object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
OBJECT-TYPE    
  Integer32 0..10  

prtInPh1MlErrorsThreshold 1.3.6.1.4.1.164.3.2.3.2.2.3.1.17
This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
OBJECT-TYPE    
  Integer32 0..10  

prtInPh1MlMaxIdleTime 1.3.6.1.4.1.164.3.2.3.2.2.3.1.18
Move to higher prioritized connected link after this period of seconds of silence on the current link. 0=Never. Never move to higher prioritized connected link. UNIT is seconds. Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300, 360, 420, 480, 540, 600, 900, 1200, 1500, 1800. Attempt to Set an invalid value will result in getting the default value.
OBJECT-TYPE    
  Integer32 0..1800  

prtInPh1MlBearerCh 1.3.6.1.4.1.164.3.2.3.2.2.3.1.19
Defines which B (bearer) channels are used for transferring ISDN data. Default value is: none (255). anyChannel (2) is skipped because it is not in use here.
OBJECT-TYPE    
  INTEGER notApplicable(1), channelB1(3), channelB2(4), chB1andchB2(5), none(255)  

prtInPh1MlAssociatedExCh 1.3.6.1.4.1.164.3.2.3.2.2.3.1.20
This object indicates the external port associated to this internal port. At present, it is used by the Hybrid (mp2100h), MHS-4 cards which can have up to 64 dynamic internal ports associated with External ports. For ISDN cards, the value will be: notApplicable (255). The associated external of an ISDN internal port is represented by the MIB object: prtIsdnDirectoryPrtNu.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), notApplicable(255)  

prtInPh1MlClockEncoding 1.3.6.1.4.1.164.3.2.3.2.2.3.1.21
This object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols.
OBJECT-TYPE    
  INTEGER notApplicable(1), nrz(2), nrzI(3), fm0(4), manchester(5), diffManchester(6)  

prtInPh1MlMinSeparators 1.3.6.1.4.1.164.3.2.3.2.2.3.1.22
Minimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable
OBJECT-TYPE    
  Integer32 0..16  

prtInPh1MlCcittCrc 1.3.6.1.4.1.164.3.2.3.2.2.3.1.23
This object indicates how many Bits are used for CRC (HDLC item).
OBJECT-TYPE    
  INTEGER notApplicable(1), crc16(2), crc32(3)  

prtInPh1MlFrameSeparator 1.3.6.1.4.1.164.3.2.3.2.2.3.1.24
This object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line.
OBJECT-TYPE    
  INTEGER notApplicable(1), idles(2), flags(3)  

prtInPh1MlDlciTable 1.3.6.1.4.1.164.3.2.3.2.2.4
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInPh1MlDlciEntry

prtInPh1MlDlciEntry 1.3.6.1.4.1.164.3.2.3.2.2.4.1
An entry in table.
OBJECT-TYPE    
  PrtInPh1MlDlciEntry  

prtInPh1MlDlciCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtInPh1MlDlciSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInPh1MlDlciPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.3
This attribute indicates a unique internal port number. MPH.1/E1 and MPH.1/T1 cards have three internal ports.
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102), inPrt3(103)  

prtInPh1MlDlciIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.4
This attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, then its type is 'user' and the only valid index is 1.
OBJECT-TYPE    
  Integer32 1..991  

prtInPh1MlDlciValid 1.3.6.1.4.1.164.3.2.3.2.2.4.1.5
This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInPh1MlDlciIConSlt 1.3.6.1.4.1.164.3.2.3.2.2.4.1.6
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInPh1MlDlciIConPrt 1.3.6.1.4.1.164.3.2.3.2.2.4.1.7
This attribute indicates a unique port id which the dlci is routed to.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), clNMS(99), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

prtInPh1MlDlciIConDlci 1.3.6.1.4.1.164.3.2.3.2.2.4.1.8
This attribute indicates a unique internal connection dlci number which the src dlci is routed to.
OBJECT-TYPE    
  Integer32 1..991  

prtInPh1MlDlciTxBc 1.3.6.1.4.1.164.3.2.3.2.2.4.1.9
This attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line.
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc9600bps(3), txBc14200bps(4), txBc19200bps(5), txBc28800bps(6), txBc32000bps(7), txBc38400bps(8), txBc48000bps(9), txBc56000bps(10), txBc57600bps(11), txBc64Kbps(12), txBc128Kbps(13), txBc192Kbps(14), txBc256Kbps(15), txBc320Kbps(16), txBc384Kbps(17), txBc448Kbps(18), txBc512Kbps(19), txBc768Kbps(20), txBc1024Kbps(21)  

prtInPh1MlDlciTxBe 1.3.6.1.4.1.164.3.2.3.2.2.4.1.10
This attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line.
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe9600bps(3), txBe14200bps(4), txBe19200bps(5), txBe28800bps(6), txBe32000bps(7), txBe38400bps(8), txBe48000bps(9), txBe56000bps(10), txBe57600bps(11), txBe64Kbps(12), txBe128Kbps(13), txBe192Kbps(14), txBe256Kbps(15), txBe320Kbps(16), txBe384Kbps(17), txBe448Kbps(18), txBe512Kbps(19), txBe768Kbps(20), txBe1024Kbps(21)  

prtInPh1MlDlciRxBc 1.3.6.1.4.1.164.3.2.3.2.2.4.1.11
This attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line.
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc9600bps(3), rxBc14200bps(4), rxBc19200bps(5), rxBc28800bps(6), rxBc32000bps(7), rxBc38400bps(8), rxBc48000bps(9), rxBc56000bps(10), rxBc57600bps(11), rxBc64Kbps(12), rxBc128Kbps(13), rxBc192Kbps(14), rxBc256Kbps(15), rxBc320Kbps(16), rxBc384Kbps(17), rxBc448Kbps(18), rxBc512Kbps(19), rxBc768Kbps(20), rxBc1024Kbps(21)  

prtInPh1MlDlciRxBe 1.3.6.1.4.1.164.3.2.3.2.2.4.1.12
This attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line.
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe9600bps(3), rxBe14200bps(4), rxBe19200bps(5), rxBe28800bps(6), rxBe32000bps(7), rxBe38400bps(8), rxBe48000bps(9), rxBe56000bps(10), rxBe57600bps(11), rxBe64Kbps(12), rxBe128Kbps(13), rxBe192Kbps(14), rxBe256Kbps(15), rxBe320Kbps(16), rxBe384Kbps(17), rxBe448Kbps(18), rxBe512Kbps(19), rxBe768Kbps(20), rxBe1024Kbps(21)  

prtInPh1MlDlciPriority 1.3.6.1.4.1.164.3.2.3.2.2.4.1.13
This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority.
OBJECT-TYPE    
  Integer32 1..8  

prtInPh1MlDlciStatus 1.3.6.1.4.1.164.3.2.3.2.2.4.1.14
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

prtPhMlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.2.5
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhMlCnfgEntry

prtPhMlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.2.5.1
An entry in table.
OBJECT-TYPE    
  PrtPhMlCnfgEntry  

prtPhMlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.5.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtPhMlSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.5.1.2
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtPhMlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.5.1.3
This attribute indicates a unique port number. ML-20 cards have just one external interface.
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtPhMlConnect 1.3.6.1.4.1.164.3.2.3.2.2.5.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtPhMlRate 1.3.6.1.4.1.164.3.2.3.2.2.5.1.5
This attribute indicates the port speed.
OBJECT-TYPE    
  INTEGER r2x64eq128Kbps(4), r3x64eq192Kbps(6), r4x64eq256Kbps(8), r5x64eq320Kbps(10), r6x64eq384Kbps(12), r7x64eq448Kbps(14), r8x64eq512Kbps(16), r9x64eq576Kbps(18), r10x64eq640Kbps(20), r11x64eq704Kbps(22), r12x64eq768Kbps(24), r13x64eq832Kbps(26), r14x64eq896Kbps(28), r15x64eq960Kbps(30), r16x64eq1024Kbps(32), r17x64eq1088Kbps(34), r18x64eq1152Kbps(36), r19x64eq1216Kbps(38), r20x64eq1280Kbps(40), r21x64eq1344Kbps(42), r22x64eq1408Kbps(44), r23x64eq1472Kbps(46), r24x64eq1536Kbps(48), r25x64eq1600Kbps(50), r26x64eq1664Kbps(52), r27x64eq1728Kbps(54), r28x64eq1792Kbps(56), r29x64eq1856Kbps(58), r30x64eq1920Kbps(60), r31x64eq1984Kbps(62)  

prtPhMlCAS 1.3.6.1.4.1.164.3.2.3.2.2.5.1.6
This attribute indicates whether Channel Associated Signaling (CAS) is used.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtPhMlClockMode 1.3.6.1.4.1.164.3.2.3.2.2.5.1.7
Clock mode.
OBJECT-TYPE    
  INTEGER dce(2), ext-dce(3), dte(4)  

prtPhMlSatBuffer 1.3.6.1.4.1.164.3.2.3.2.2.5.1.8
Satellite Buffer (+/- 256).
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtPhMlDialProcess 1.3.6.1.4.1.164.3.2.3.2.2.5.1.9
Dial Process.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), callIn(3), callOut(4)  

prtPhMlSyncRestore 1.3.6.1.4.1.164.3.2.3.2.2.5.1.10
Sync Restoration time, in seconds. notApplicable=0.
OBJECT-TYPE    
  Integer32 0..10  

prtPhMlBus 1.3.6.1.4.1.164.3.2.3.2.2.5.1.11
The TDM BUS this port is linked to.
OBJECT-TYPE    
  INTEGER none(1), busA(2), busB(3)  

prtPhMlMfSyncSlot 1.3.6.1.4.1.164.3.2.3.2.2.5.1.12
This attribute indicates whether the sync is synchronized according to a certain card and the slot of this card. This operation is required in order to bypass signaling of PCM voice channels. In the ?004 Unit the entries io6(10)..io12(16) are not valid
OBJECT-TYPE    
  INTEGER none(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtPhPlCnfg 1.3.6.1.4.1.164.3.2.3.2.3
OBJECT IDENTIFIER    

prtExPhPlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.3.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPhPlCnfgEntry

prtExPhPlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.3.1.1
An entry in table.
OBJECT-TYPE    
  PrtExPhPlCnfgEntry  

prtExPhPlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.3.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtExPhPlSltIdx 1.3.6.1.4.1.164.3.2.3.2.3.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.3.1.1.3
This attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtExPhPlConnect 1.3.6.1.4.1.164.3.2.3.2.3.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPhPlHRate 1.3.6.1.4.1.164.3.2.3.2.3.1.1.5
This attribute indicates the port speed for HIGH speed cards. The card has limitations about the maximum sigma channel speeds and about the possible rates for each clock mode . N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. 'r9d6KbpsNLE' means rate of 9.6 Kbps ('d'=dot). Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r2048KbpsE (63), -- r2048KbpsNLE
OBJECT-TYPE    
  INTEGER notApplicable(1), r32KbpsNLE(2), r48KbpsNLE(3), r56KbpsNLE(4), r64KbpsNLE(5), r112KbpsNLE(6), r128KbpsNLE(7), r168KbpsNLE(8), r192KbpsNLE(9), r224KbpsNLE(10), r256KbpsNLE(11), r280KbpsE(12), r320KbpsE(13), r336KbpsNLE(14), r384KbpsNLE(15), r392KbpsE(16), r448KbpsNLE(17), r504KbpsLE(18), r512KbpsE(19), r560KbpsE(20), r576KbpsLE(21), r616KbpsE(22), r640KbpsE(23), r672KbpsNLE(24), r704KbpsE(25), r728KbpsE(26), r768KbpsNLE(27), r784KbpsE(28), r832KbpsE(29), r840KbpsE(30), r896KbpsNLE(31), r952KbpsE(32), r960KbpsE(33), r1008KbpsLE(34), r1024KbpsE(35), r1064KbpsE(36), r1088KbpsE(37), r1120KbpsE(38), r1152KbpsLE(39), r1176KbpsE(40), r1216KbpsE(41), r1232KbpsE(42), r1280KbpsE(43), r1288KbpsE(44), r1344KbpsNLE(45), r1400KbpsE(46), r1408KbpsE(47), r1456KbpsE(48), r1472KbpsE(49), r1512KbpsE(50), r1536KbpsE(51), r1568KbpsE(52), r1600KbpsE(53), r1624KbpsE(54), r1664KbpsE(55), r1680KbpsE(56), r1728KbpsE(57), r1736KbpsE(58), r1792KbpsNLE(59), r1856KbpsE(60), r1920KbpsE(61), r1984KbpsE(62), r2048KbpsE(63), r9d6KbpsNLE(65), r14d4KbpsNLE(66), r16KbpsNLE(67), r19d2KbpsNLE(68), r28d8KbpsNLE(69), r38d4KbpsNLE(70), r57d6KbpsNLE(71), r115d2KbpsNLE(72), r24000bps(73)  

prtExPhPlLRate 1.3.6.1.4.1.164.3.2.3.2.3.1.1.6
This attribute indicates the port speed for LOW speed cards. The card has limitations about the possible rates for each clock mode. N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r57600bpsLE (16), -- r57600bpsNLE
OBJECT-TYPE    
  INTEGER notApplicable(1), r300bpsNLE(2), r600bpsNLE(3), r800bpsNLE(4), r1200bpsNLE(5), r2400bpsNLE(6), r4800bpsNLE(7), r9600bpsNLE(8), r14400bpsLE(9), r19200bpsNLE(10), r28800bpsLE(11), r32000bpsNLE(12), r38400bpsNLE(13), r48000bpsNLE(14), r56000bpsNLE(15), r57600bpsLE(16), r64000bpsNLE(17), r112000bps(18), r115200bps(19), r16000bpsNLE(20), r100bpsNLE(21), r128000bps(22), r24000bps(23)  

prtExPhPlProtocol 1.3.6.1.4.1.164.3.2.3.2.3.1.1.7
This object indicates the applied protocol.
OBJECT-TYPE    
  INTEGER fr(1), frPlus(2), pCellRelay(3), hdlcSdlc(4), transparentHdlc(5), async(6), asyncReliable(7), activePPP(8), slip(9), pppAgent(10), slipAgent(11), transparent(12), sna(13)  

prtExPhPlConnectionTyp 1.3.6.1.4.1.164.3.2.3.2.3.1.1.8
This attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management opration (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetMotMana - indicates network internal line, but the remote mux is not managed by the NMS. User - User to Network Interface. OtherNet - Network To Network Interface. PubNet - Access Mux To PubNet Interface.
OBJECT-TYPE    
  INTEGER sameNetManaged(1), sameNetNotMana(2), user(3), otherNet(4), pubNet(5), notApplicable(255)  

prtExPhPlClkMode 1.3.6.1.4.1.164.3.2.3.2.3.1.1.9
Clock mode.
OBJECT-TYPE    
  INTEGER dce(1), extDce(2), dte(3), int(4), lbt(5)  

prtExPhPlDceClkSrc 1.3.6.1.4.1.164.3.2.3.2.3.1.1.10
This attribute indicates the source of the clock when working in dce or ext-dce clock mode. notApplicable(1) - is applied for dte(3) and lbt(5) clock modes. When clock mode is dte, the clock source is always external, therefore this object's value is notApplicable. local(2) and nodalTiming(3) - are valid in dce(1), extDce(2) or int(4) clock modes. The recommended clock source is local(2).
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), nodalTiming(3)  

prtExPhPlCongResponse 1.3.6.1.4.1.164.3.2.3.2.3.1.1.11
This attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/received becn to/from the network). no - do nothing flowControl - translates the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done on both directions. toFlowControl- translates the backward congestion indication received from the internal connection port (normally the network side) to flow control and do nothing in the other direction.
OBJECT-TYPE    
  INTEGER no(2), flowControl(3), toFlowControl(4)  

prtExPhPlCongLevel 1.3.6.1.4.1.164.3.2.3.2.3.1.1.12
This attribute indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5 percent.
OBJECT-TYPE    
  Integer32 0..70  

prtExPhPlTc 1.3.6.1.4.1.164.3.2.3.2.3.1.1.13
This attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports of a specific card .
OBJECT-TYPE    
  INTEGER tc1sec(1), tc2sec(2), tc3sec(3), tc4sec(4), notApplicable(255)  

prtExPhPlFlowControl 1.3.6.1.4.1.164.3.2.3.2.3.1.1.14
This attribute indicates the required flow control betweeen the port and the remote equipment. fecnBecn - is valid only for FR, FR+ and CR protocols. xonXoff,dtrCts - are valid only for Async protocols. speedReduction - is valid only for DLC protocol when the Clock Mode is DCE and the Clock Source is Local.
OBJECT-TYPE    
  INTEGER none(2), fecnBecn(3), xonXoff(4), dtrCts(5), speedReduction(6)  

prtExPhPlDcdRts 1.3.6.1.4.1.164.3.2.3.2.3.1.1.15
Protocol may require end to end connect indication over the network. End to end link connection establishment over the FR network will be indicated to the user by using DCD or RTS control signals, depending on the clock mode: DCE or DTE respectively. The options are : - On : DCD(DCE)/RTS(DTE) will be constantly ON no matter if the End to End connection is established or not. - End to End: The DCD(DCE)/RTS(DTE) will be according to the status of the End to End connection.
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), endToEnd(3)  

prtExPhPlDcdRtsControlPath 1.3.6.1.4.1.164.3.2.3.2.3.1.1.16
Protocol may require end to end connect indication over the network. This parameter defines whether to take the user connection status (RTS(DCE)/DCD(DTE)) and forward it to the network side. - on : Transmit active connection to the network regardless the RTS/DCD control lines status. - off: Transmit active connection to the network according to the status of the RTS/DCD pin.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtExPhPlDataBits 1.3.6.1.4.1.164.3.2.3.2.3.1.1.17
This attribute indicates the number of data bits in async frame. It is relevant only for Async protocols.
OBJECT-TYPE    
  INTEGER notApplicable(1), dataBits7Bits(2), dataBits8Bits(3)  

prtExPhPlParity 1.3.6.1.4.1.164.3.2.3.2.3.1.1.18
This attribute indicates the parity operation mode in async frame. It is relevant only for Async protocols.
OBJECT-TYPE    
  INTEGER notApplicable(1), odd(2), even(3), none(4)  

prtExPhPlStopBits 1.3.6.1.4.1.164.3.2.3.2.3.1.1.19
This attribute indicates the minimum number of stop bits in the tx async frame. It is relevant only for Async protocols.
OBJECT-TYPE    
  INTEGER notApplicable(1), sb1Bit(2), sb1dot5Bits(3), sb2Bits(4)  

prtExPhPlLXon 1.3.6.1.4.1.164.3.2.3.2.3.1.1.20
This attribute indicates the character used as X-On to notify receive enable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable
OBJECT-TYPE    
  Integer32  

prtExPhPlLXoff 1.3.6.1.4.1.164.3.2.3.2.3.1.1.21
This attribute indicates the character used as X-Off to notify receive disable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable
OBJECT-TYPE    
  Integer32  

prtExPhPlFrMngProt 1.3.6.1.4.1.164.3.2.3.2.3.1.1.22
This object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtExPhPlConnectionTyp = sameNetManaged, this object will be RO (internally determined).
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), lmi(3), ansiT1(4), annexA(5)  

prtExPhPlEnqPeriod 1.3.6.1.4.1.164.3.2.3.2.3.1.1.23
This object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
OBJECT-TYPE    
  Integer32 1..30  

prtExPhPlFullRptPeriod 1.3.6.1.4.1.164.3.2.3.2.3.1.1.24
This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
OBJECT-TYPE    
  Integer32 1..255  

prtExPhPlFrWindowSize 1.3.6.1.4.1.164.3.2.3.2.3.1.1.25
This object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
OBJECT-TYPE    
  Integer32 1..10  

prtExPhPlErrorsThreshold 1.3.6.1.4.1.164.3.2.3.2.3.1.1.26
This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
OBJECT-TYPE    
  Integer32 1..10  

prtExPhPlPvcCreateMsg 1.3.6.1.4.1.164.3.2.3.2.3.1.1.27
This object is Update Message (if required or not). It determines whether a message of a New PVC Creation is requested or not (yes/no). Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPhPlCllmMsg 1.3.6.1.4.1.164.3.2.3.2.3.1.1.28
This object is CLLM Message (if required or not). It determines whether to send (or not) a congestion message when the port is Rx congested. Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPhPlProtDelayLevel 1.3.6.1.4.1.164.3.2.3.2.3.1.1.29
This object is the Segmentation in Bytes. In some cases, the enumerated values will mean other segmentation values than specified: Product: MX-3000 MX-3000 MX-300/MX-30 Protocol: FR+ Transparent FR+ ----------------------------------------------------- level 1 50 Bytes 44 Bytes 50 Bytes level 2 158 Bytes 155 Bytes 158 Bytes level 3 266 Bytes 266 Bytes 266 Bytes level 4 376 Bytes 377 Bytes 376 Bytes level 5 484 Bytes 488 Bytes 484 Bytes Defval=level 1 value This parameter is applicable only for FR+ and transparent protocols.
OBJECT-TYPE    
  INTEGER notApplicable(1), s36Byte(2), s150Byte(3), s264Byte(4), s378Byte(5), s492Byte(6)  

prtExPhPlClockEncoding 1.3.6.1.4.1.164.3.2.3.2.3.1.1.30
This object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols. For MAXCESS 3000 & MP2100H: when setting to nrzI (3) the nrzI works as nrzI Mark. For MAXCESS 30/300 when setting to nrzI (3) the nrzI works as nrzI Space.
OBJECT-TYPE    
  INTEGER notApplicable(1), nrz(2), nrzI(3), fm0(4), manchester(5), diffManchester(6), nrzISpace(7), nrzIMark(8)  

prtExPhPlMinSeparators 1.3.6.1.4.1.164.3.2.3.2.3.1.1.31
Minimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable
OBJECT-TYPE    
  Integer32 0..16  

prtExPhPlCcittCrc 1.3.6.1.4.1.164.3.2.3.2.3.1.1.32
This object indicates how many Bits are used for CRC (HDLC item).
OBJECT-TYPE    
  INTEGER notApplicable(1), crc16(2), crc32(3)  

prtExPhPlFrameSeparator 1.3.6.1.4.1.164.3.2.3.2.3.1.1.33
This object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line.
OBJECT-TYPE    
  INTEGER notApplicable(1), idles(2), flags(3)  

prtExPhPlIdleCode 1.3.6.1.4.1.164.3.2.3.2.3.1.1.34
Determines the code for transmission when there are no frames to transmit on the line. The value should be 0 to FFH.
OBJECT-TYPE    
  Integer32  

prtExPhPlJitter 1.3.6.1.4.1.164.3.2.3.2.3.1.1.35
Maximum variant delay of the FR network, in msec.
OBJECT-TYPE    
  Integer32 0..1000  

prtExPhPlDlciTable 1.3.6.1.4.1.164.3.2.3.2.3.2
The write operation into the Table Objects is valid only at the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPhPlDlciEntry

prtExPhPlDlciEntry 1.3.6.1.4.1.164.3.2.3.2.3.2.1
An entry in table.
OBJECT-TYPE    
  PrtExPhPlDlciEntry  

prtExPhPlDlciCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtExPhPlDlciSltIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlDlciPrtIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.3
This attribute indicates a unique internal port number. PH.1/E1 and PH.1/T1 cards have three internal ports. Stand-alone units may have six such ports.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtExPhPlDlciIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.4
This attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, its type is 'user' and the only valid index is 1.
OBJECT-TYPE    
  Integer32 1..991  

prtExPhPlDlciValid 1.3.6.1.4.1.164.3.2.3.2.3.2.1.5
This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPhPlDlciIConSlt 1.3.6.1.4.1.164.3.2.3.2.3.2.1.6
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. cl - will represent any of the CL slots. This value can be selected for multiple DLCIs of the product. In the ?004 Unit the entries io6(10)..io16) are not valid
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlDlciIConPrt 1.3.6.1.4.1.164.3.2.3.2.3.2.1.7
This attribute indicates a unique port id which the dlci is routed to. clNMS - will be used for NMS SNMP messages. It can be any port of the CL card. This value will be selectable only if prtExPhPlDlciIConSlt='cl' or 'notApplicable'.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), clNMS(99), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110)  

prtExPhPlDlciIConDlci 1.3.6.1.4.1.164.3.2.3.2.3.2.1.8
This attribute indicates a unique internal connection dlci number, the dlci is routed to.
OBJECT-TYPE    
  Integer32 1..991  

prtExPhPlDlciTxBc 1.3.6.1.4.1.164.3.2.3.2.3.2.1.9
This attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line).
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc9600bps(3), txBc14400bps(4), txBc19200bps(5), txBc28800bps(6), txBc32000bps(7), txBc38400bps(8), txBc48000bps(9), txBc56000bps(10), txBc57600bps(11), txBc64Kbps(12), txBc128Kbps(13), txBc192Kbps(14), txBc256Kbps(15), txBc320Kbps(16), txBc384Kbps(17), txBc448Kbps(18), txBc512Kbps(19), txBc768Kbps(20), txBc1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPhPlDlciTxBe 1.3.6.1.4.1.164.3.2.3.2.3.2.1.10
This attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line).
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe9600bps(3), txBe14400bps(4), txBe19200bps(5), txBe28800bps(6), txBe32000bps(7), txBe38400bps(8), txBe48000bps(9), txBe56000bps(10), txBe57600bps(11), txBe64Kbps(12), txBe128Kbps(13), txBe192Kbps(14), txBe256Kbps(15), txBe320Kbps(16), txBe384Kbps(17), txBe448Kbps(18), txBe512Kbps(19), txBe768Kbps(20), txBe1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPhPlDlciRxBc 1.3.6.1.4.1.164.3.2.3.2.3.2.1.11
This attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line).
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc9600bps(3), rxBc14400bps(4), rxBc19200bps(5), rxBc28800bps(6), rxBc32000bps(7), rxBc38400bps(8), rxBc48000bps(9), rxBc56000bps(10), rxBc57600bps(11), rxBc64Kbps(12), rxBc128Kbps(13), rxBc192Kbps(14), rxBc256Kbps(15), rxBc320Kbps(16), rxBc384Kbps(17), rxBc448Kbps(18), rxBc512Kbps(19), rxBc768Kbps(20), rxBc1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPhPlDlciRxBe 1.3.6.1.4.1.164.3.2.3.2.3.2.1.12
This attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line).
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe9600bps(3), rxBe14400bps(4), rxBe19200bps(5), rxBe28800bps(6), rxBe32000bps(7), rxBe38400bps(8), rxBe48000bps(9), rxBe56000bps(10), rxBe57600bps(11), rxBe64Kbps(12), rxBe128Kbps(13), rxBe192Kbps(14), rxBe256Kbps(15), rxBe320Kbps(16), rxBe384Kbps(17), rxBe448Kbps(18), rxBe512Kbps(19), rxBe768Kbps(20), rxBe1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPhPlDlciPriority 1.3.6.1.4.1.164.3.2.3.2.3.2.1.13
This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority.
OBJECT-TYPE    
  Integer32 1..8  

prtExPhPlDlciStatus 1.3.6.1.4.1.164.3.2.3.2.3.2.1.14
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

prtExPhPlModemTable 1.3.6.1.4.1.164.3.2.3.2.3.3
External Modem Parameters. The write operation into the Table Objects is valid only for the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPhPlModemEntry

prtExPhPlModemEntry 1.3.6.1.4.1.164.3.2.3.2.3.3.1
An entry in table.
OBJECT-TYPE    
  PrtExPhPlModemEntry  

prtExPhPlModemCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.3.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtExPhPlModemSltIdx 1.3.6.1.4.1.164.3.2.3.2.3.3.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlModemPrtIdx 1.3.6.1.4.1.164.3.2.3.2.3.3.1.3
This attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtExPhPlModemStatus 1.3.6.1.4.1.164.3.2.3.2.3.3.1.4
This object indicates whether a Dial Up Modem is enabled on this port. Default: disable
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

prtExPhPlModemActivate 1.3.6.1.4.1.164.3.2.3.2.3.3.1.5
This object indicates whether the Dial Up Modem is activated when the first frame is received or it is always activated. Default: onFirstFrame
OBJECT-TYPE    
  INTEGER onFirstFrame(2), always(3), notApplicable(255)  

prtExPhPlModemMaxIdleTime 1.3.6.1.4.1.164.3.2.3.2.3.3.1.6
Max Time allowed in Seconds without any traffic before the line is disconnected. Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec.. 1 min, 2 min .. 10 min, 15 min, 20 min, 25 min, 30 min. 65535 sec. means that this parameter is not applicable. Default: 1 sec.
OBJECT-TYPE    
  Integer32  

prtExPhPlModemTimeBtwnCalls 1.3.6.1.4.1.164.3.2.3.2.3.3.1.7
Minimum Time in Seconds which is required after a call was disconnected. In this time no other call will be initiated from this Modem port even if there were frames transmitted to this port. This time is required for some Modems which have initializations that take a few seconds. Legal Values are: 0 sec. - 30 sec., 1-5 min. 65535 sec. means that this parameter is not applicable. Default: 0 sec
OBJECT-TYPE    
  Integer32  

prtExPhPlModemCallDelay 1.3.6.1.4.1.164.3.2.3.2.3.3.1.8
Time in Seconds that the device will wait before dialing to the remote device. This feature is mostly used when there is a backup modem to the main link and the main link is down. In this case it is important to prevent the 2 devices from dialing through the backup modems to each other at the same time. It is advised to configure one side with a small call delay and the other side with a large call delay. Legal Values are: 0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 . 65535 sec. means that this parameter is not applicable. Default: 0 sec
OBJECT-TYPE    
  Integer32  

prtLs2Cnfg 1.3.6.1.4.1.164.3.2.3.2.4
OBJECT IDENTIFIER    

prtExLs2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.4.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExLs2CnfgEntry

prtExLs2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.4.1.1
An entry in table.
OBJECT-TYPE    
  PrtExLs2CnfgEntry  

prtExLs2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExLs2SltIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExLs2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.3
This attribute indicates a unique port index. For the Ls2/X.58 exPrt(7)..exPrt(10) are not valid.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10)  

prtExLs2Connect 1.3.6.1.4.1.164.3.2.3.2.4.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExLs2Rate 1.3.6.1.4.1.164.3.2.3.2.4.1.1.5
Port rates.
OBJECT-TYPE    
  INTEGER r2400bps(2), r4800bps(3), r9600bps(4), r19200bps(5)  

prtExLs2ClkMode 1.3.6.1.4.1.164.3.2.3.2.4.1.1.6
This attribute indicates a unique port operation clock mode.
OBJECT-TYPE    
  INTEGER dce(1), ext-dce(2), dte(3)  

prtExLs2Cts 1.3.6.1.4.1.164.3.2.3.2.4.1.1.7
CTS.
OBJECT-TYPE    
  INTEGER on(2), rts-min(3), rts-max(4)  

prtExLs2Dcd 1.3.6.1.4.1.164.3.2.3.2.4.1.1.8
DCD.
OBJECT-TYPE    
  INTEGER on(2), card-sync(3)  

prtExLs2EnvIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.9
Envelope Index. When prtInLs2EnvAssign=auto, the value is 0 (not applicable).
OBJECT-TYPE    
  Integer32 0..24  

prtInLs2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.4.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInLs2CnfgEntry

prtInLs2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.4.2.1
An entry in table.
OBJECT-TYPE    
  PrtInLs2CnfgEntry  

prtInLs2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.4.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtInLs2SltIdx 1.3.6.1.4.1.164.3.2.3.2.4.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInLs2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.4.2.1.3
This attribute indicates a unique internal port index.
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102)  

prtInLs2Connect 1.3.6.1.4.1.164.3.2.3.2.4.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInLs2Group 1.3.6.1.4.1.164.3.2.3.2.4.2.1.5
This attribute indicates the group number of the port. LS-2 internal ports with the same group number share the same Time slot of the main link
OBJECT-TYPE    
  Integer32 1..12  

prtInLs2Member 1.3.6.1.4.1.164.3.2.3.2.4.2.1.6
This attribute indicates the group member id of the port. This parameter is for the automatic envelope assignment algorithm.
OBJECT-TYPE    
  Integer32 1..4  

prtInLs2LinkTo 1.3.6.1.4.1.164.3.2.3.2.4.2.1.7
It indicates the slot of the main link card to which the LS2 card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInLs2EnvAssign 1.3.6.1.4.1.164.3.2.3.2.4.2.1.8
Envelope assignment type.
OBJECT-TYPE    
  INTEGER auto(2), manual(3)  

prtVc2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.5
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtVc2CnfgEntry

prtVc2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.5.1
An entry in table.
OBJECT-TYPE    
  PrtVc2CnfgEntry  

prtVc2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.5.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtVc2SltIdx 1.3.6.1.4.1.164.3.2.3.2.5.1.2
This attribute indicates a unique slot position where the card is inserted. For Stand Alone products like WR: notApplicable (255)
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtVc2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.5.1.3
A unique identifier of the port, within the card. For Megaplex card ports, Web Ranger and FCD-IP Voice ports the values will be: exPrt1 (1) exPrt2 (2) exPrt3 (3) exPrt4 (4) exPrt5 (5) exPrt6 (6) exPrt7 (7) exPrt8 (8) exPrt9 (9) exPrt10 (10) exPrt11 (11) exPrt12 (12) exPrt13 (13) exPrt14 (14) exPrt15 (15) exPrt16 (16) For LA-240: The index for fixed voice ports will be - exPrt6 (6) exPrt7 (7) exPrt8 (8) exPrt9 (9) The index for voice card ports will be - Slot number * 100 + ch (for IO-1: 101..104, for IO-2: 201..204).
OBJECT-TYPE    
  Integer32  

prtExVc2Connect 1.3.6.1.4.1.164.3.2.3.2.5.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3), v51(4)  

prtExVc2TransGain 1.3.6.1.4.1.164.3.2.3.2.5.1.5
Transmit gain in dBm. For ports of VC-6A, VC-6AG, VC-8 and VC-16 cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps.
OBJECT-TYPE    
  Integer32  

prtExVc2ReceiveGain 1.3.6.1.4.1.164.3.2.3.2.5.1.6
Receive gain in dBm. For ports of VC-6A, VC-6AG, VC-8 and VC-16 cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps.
OBJECT-TYPE    
  Integer32  

prtExVc2Wire 1.3.6.1.4.1.164.3.2.3.2.5.1.7
For some cards, this object is equal for all the ports in the specific card because of HW limitations. For FXO & FXS this parameter is not applicable.
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2), notApplicable(255)  

prtExVc2CodingLaw 1.3.6.1.4.1.164.3.2.3.2.5.1.8
This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations
OBJECT-TYPE    
  INTEGER aLAW(1), uLAW(2)  

prtExVc2Sig 1.3.6.1.4.1.164.3.2.3.2.5.1.9
This attribute indicates the method for decoding/encoding the signaling information(on/off hook). noSignaling (1) - not using signaling (only voice). robbedBitMultiFrame(2) - is the standard method for T1 links and proprietary method for E1 links. chAssociatedE1 (3) - is valid only for E1 G.732S links. robbedBitFrame (4) - is proprietary method implimenting 7 bit for the voice and 1 bit dedicated for signaling. For some cards, this object is equal for all the ports in the specific module because of HW limitations.
OBJECT-TYPE    
  INTEGER noSignaling(1), robbedBitMultiFrame(2), chAssociatedE1(3), robbedBitFrame(4)  

prtExVc2Oos 1.3.6.1.4.1.164.3.2.3.2.5.1.10
This object is equal for all the ports in the specific card because of HW limitations
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2), busyIdle(3), idleBusy(4), notApplicable(5)  

prtExVc2LinkTo 1.3.6.1.4.1.164.3.2.3.2.5.1.11
This attribute indicates the slot of the ML card to which the VC card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVc2OperMode 1.3.6.1.4.1.164.3.2.3.2.5.1.12
This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request.
OBJECT-TYPE    
  INTEGER normal(2), unidirectRx(3), broadcast(4)  

prtExVc2SigProfile 1.3.6.1.4.1.164.3.2.3.2.5.1.13
This object indicates the Signaling Profile of the port. notApplicable - for VC-2 family and when prtExVc2Sig=noSignaling(1) p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4
OBJECT-TYPE    
  INTEGER notApplicable(1), manual(2), p1(3), p2(4), p3Fxo3S3(5), reversePolarity(6), meteringPulse(7), p4(8)  

prtExVc2CallEnable 1.3.6.1.4.1.164.3.2.3.2.5.1.14
This object indicates the Enabled Call direction. notApplicable - for all cards except VC-2/R2. both - incoming + outgoing.
OBJECT-TYPE    
  INTEGER notApplicable(1), incoming(2), outgoing(3), both(4)  

prtExVc2R2Delay 1.3.6.1.4.1.164.3.2.3.2.5.1.15
This object indicates the R2 Delay. notApplicable - for all cards except VC-2/R2.
OBJECT-TYPE    
  INTEGER notApplicable(1), terrestrial(2), satellite(3)  

prtExVc2CasStd 1.3.6.1.4.1.164.3.2.3.2.5.1.16
This object indicates the CAS (Channel Associated Signaling) Standard. notApplicable - for all cards except VC-2/R2.
OBJECT-TYPE    
  INTEGER notApplicable(1), r2Q422(2), specialA(3), specialB(4), specialC(5), specialD(6), specialE(7), specialF(8), specialG(9)  

prtExVc2EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.5.1.17
Echo canceler activation. notApplicable - for VC-2 and VC-6 cards.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtExVc2IfType 1.3.6.1.4.1.164.3.2.3.2.5.1.18
Interface Type.
OBJECT-TYPE    
  INTEGER notApplicable(1), w2Em(2), w4Em(3), fxo(4), fxs(5)  

prtExVc2Encoding 1.3.6.1.4.1.164.3.2.3.2.5.1.19
Voice Encoding Mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), pcm(2), adpcm(3)  

prtExVc2TxBitCode 1.3.6.1.4.1.164.3.2.3.2.5.1.20
- - - For MP & FCD - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = M lead 2 hex = 0010 = M lead inverse 3 hex = 0011 = Reverse Polarity 4 hex = 0100 = Metering Pulse 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For WR II - - - This object represents the following 4 parameters by 2 Octets: 1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1). 2. Default signaling bits that are not in use (nibble 2). 3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3). 4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook Default sig. Ring Detect. M (Mouth) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable 1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit 2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv. 3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit 4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv. 5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid 6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid 7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid 8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid 9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid C-F hex not used-invalid ABCD not Used-invalid not Used-invalid Default value: 11 11
OBJECT-TYPE    
  OCTET STRING  

prtExVc2RxBitOutput 1.3.6.1.4.1.164.3.2.3.2.5.1.21
- - - For MP (VC-Q card only) & FCD - - - This object represents 3 parameters by 2 Octets: Spare -MSB nibble, always=0 hex E Lead Output - nibble, Reverse Polarity Output- nibble, Metering Pulse Output -LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = Rx A bit 2 hex = 0010 = Rx A bit inverse 3 hex = 0011 = Rx B bit 4 hex = 0100 = Rx B bit inverse 5 hex = 0101 = Rx C bit 6 hex = 0110 = Rx C bit inverse 7 hex = 0111 = Rx D bit 8 hex = 1000 = Rx D bit inverse 9 hex = 1001 = none A-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For MP (VC-8, VC-16, VC-16A cards) - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = not used (invalid value) 2 hex = 0010 = not used (invalid value) 3 hex = 0011 = not used (invalid value) 4 hex = 0100 = not used (invalid value) 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO. - - - For WR II - - - This object represents the following 2 parameters in 1 Octet: 1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1). 2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook E (Ear) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable 1 hex = 0001 Rx A bit Rx A bit 2 hex = 0010 Rx A bit inverse Rx A bit inverse 3 hex = 0011 Rx B bit Rx B bit 4 hex = 0100 Rx B bit inverse Rx B bit inverse 5-F hex not used-invalid not Used-invalid Default value: 11
OBJECT-TYPE    
  OCTET STRING  

prtExVc2MeterRate 1.3.6.1.4.1.164.3.2.3.2.5.1.22
This entry is applicable only for VC-6A/FXO, VC-6A/FXS, VC-8/FXO, VC-8/FXS, VC-16/FXO and VC-16/FXS. Meter Rate means rate of Call Meter in Public Phones, in KHz units. For some cards, the value must be the same for all card's ports.
OBJECT-TYPE    
  INTEGER notApplicable(1), r16Khz(2), r12Khz(3)  

prtExVc2IfSignaling 1.3.6.1.4.1.164.3.2.3.2.5.1.23
This entry is applicable only for VC-6A, VC-6AG, VC-8/FXO, VC-8/FXS, VC-16/FXO and VC-16/FXS cards. Interface Analog Signaling. Must be the same for all card's ports. loopStart - for the usual trunk/phone types. groundStart - for trunks that need Ground signaling . winkStart - for trunks that need Reverse Polarity.
OBJECT-TYPE    
  INTEGER notApplicable(1), loopStart(2), groundStart(3), winkStart(4)  

prtExVc2SeizeAck 1.3.6.1.4.1.164.3.2.3.2.5.1.24
This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Default value for WR FXO: no(2).
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExVc2EandMType 1.3.6.1.4.1.164.3.2.3.2.5.1.25
This is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters.
OBJECT-TYPE    
  INTEGER notApplicable(1), type1(2), type2(3), type3(4), type5(5)  

prtExVc2RemType 1.3.6.1.4.1.164.3.2.3.2.5.1.26
Remote Type. Applicable for VC-6A/4LB card & for IPMUX-1E Far End Type - E1,T1(T1-ESF) or T1-D4 .
OBJECT-TYPE    
  INTEGER notApplicable(1), lb(2), pbx(3), e1(4), t1(5), t1D4(6)  

prtExVc2ConvTime 1.3.6.1.4.1.164.3.2.3.2.5.1.27
Conversation Time in minutes. Applicable for VC-6A/4LB card.
OBJECT-TYPE    
  INTEGER notApplicable(1), m2(2), m3(3), m5(4), unlimited(5)  

prtExVc2SigFeedback 1.3.6.1.4.1.164.3.2.3.2.5.1.28
Signaling Feedback. Applicable for VC-8/FXO and VC-16/FXO cards.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExVc2EchoCancelerModule 1.3.6.1.4.1.164.3.2.3.2.5.1.29
This parameter indicates whether Echo canceler module exists for this port.
OBJECT-TYPE    
  INTEGER notApplicable(1), notExist(2), exist(3)  

prtHsfCnfgTable 1.3.6.1.4.1.164.3.2.3.2.6
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHsfCnfgEntry

prtHsfCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.6.1
An entry in table.
OBJECT-TYPE    
  PrtHsfCnfgEntry  

prtHsfCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.6.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relate to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtHsfSltIdx 1.3.6.1.4.1.164.3.2.3.2.6.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtHsfPrtIdx 1.3.6.1.4.1.164.3.2.3.2.6.1.3
This attribute indicates a unique external port index. Hs2 has only two ports (exPrt1,exPrt2). Hs3 has three ports (exPrt1,exPrt2,exPrt3). Hsq and hsqN has four ports. Hs6 has six external ports. Hs12 has twelve external ports.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtExHsfConnect 1.3.6.1.4.1.164.3.2.3.2.6.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExHsfRate 1.3.6.1.4.1.164.3.2.3.2.6.1.5
This attribute indicates the port speed.
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17), r9x64eq576Kbps(18), r10x56eq560Kbps(19), r10x64eq640Kbps(20), r11x56eq616Kbps(21), r11x64eq704Kbps(22), r12x56eq672Kbps(23), r12x64eq768Kbps(24), r13x56eq728Kbps(25), r13x64eq832Kbps(26), r14x56eq784Kbps(27), r14x64eq896Kbps(28), r15x56eq840Kbps(29), r15x64eq960Kbps(30), r16x56eq896Kbps(31), r16x64eq1024Kbps(32), r17x56eq952Kbps(33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), r32Kbps(63)  

prtExHsfClkMode 1.3.6.1.4.1.164.3.2.3.2.6.1.6
This attribute indicates a unique port operation clock mode.
OBJECT-TYPE    
  INTEGER dce(1), ext-dce(2), dte(3), none(4)  

prtExHsfCts 1.3.6.1.4.1.164.3.2.3.2.6.1.7
This attribute indicates a unique CTS control line operation mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3)  

prtExHsfFifoSize 1.3.6.1.4.1.164.3.2.3.2.6.1.8
Size in bits.
OBJECT-TYPE    
  INTEGER auto(2), s16bits(3), s30bits(4), s52bits(5), s72bits(6)  

prtExHsfLinkTo 1.3.6.1.4.1.164.3.2.3.2.6.1.9
This attribute indicates a slot of Main Link module, that the port is linked to. This object is the same for all the ports in the specific card because of HW limitations. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsfOperMode 1.3.6.1.4.1.164.3.2.3.2.6.1.10
This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request.
OBJECT-TYPE    
  INTEGER normal(2), unidirectRx(3), broadcast(4)  

prtExHsfInbandLoopback 1.3.6.1.4.1.164.3.2.3.2.6.1.11
This object indicates if Inband Loopback from the Network should be enabled or disabled.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), ft1Enabled(3)  

prtExHsfClkPolarity 1.3.6.1.4.1.164.3.2.3.2.6.1.12
This object indicates the clock polarity. For FCD-M this object will be applicable only for the fixed HS port (the fixed port on the device).
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), invert(3)  

prtExHsfControlSignal 1.3.6.1.4.1.164.3.2.3.2.6.1.13
This object indicates the Control Signal according to G.797 ITU-T standard. For FCD-M this object will be applicable for the fixed HS port (the fixed port on the device) and HS-Q/N channels. Local and End to End are applicable only when channel Interface type is RS-530, else it will be Not Applicable.
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), endToEnd(3)  

prtHs4Cnfg 1.3.6.1.4.1.164.3.2.3.2.7
OBJECT IDENTIFIER    

prtExHs4CnfgTable 1.3.6.1.4.1.164.3.2.3.2.7.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHs4CnfgEntry

prtExHs4CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.7.1.1
An entry in table.
OBJECT-TYPE    
  PrtExHs4CnfgEntry  

prtExHs4CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.7.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExHs4SltIdx 1.3.6.1.4.1.164.3.2.3.2.7.1.1.2
This attribute indicates a unique slot position where the card is inserted.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHs4PrtIdx 1.3.6.1.4.1.164.3.2.3.2.7.1.1.3
A unique identifier of the port, within the card.
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExHs4Connect 1.3.6.1.4.1.164.3.2.3.2.7.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithm. It also affects all the module considerations because the card has only one external (physical) interface.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExHs4LineType 1.3.6.1.4.1.164.3.2.3.2.7.1.1.5
This attribute is the line type parameter for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the HS-4/1 and E1 line code parameters for the HS-4/2. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) dsx1ESF (2) dsx1D4 (3) dsx1E1 (4) dsx1E1-CRC (5) dsx1E1-MF (6) dsx1E1-MF-CRC (7)
OBJECT-TYPE    
  INTEGER esfT1(2), sfT1(3), g732nE1(4), g732nE1CRC(5), g732sE1(6), g732sE1CRC(7)  

prtExHs4LineCode 1.3.6.1.4.1.164.3.2.3.2.7.1.1.6
This attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the MPH.1/T1 and E1 line code parameters for the MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
OBJECT-TYPE    
  INTEGER b7T1(1), b8zsT1(2), hdb3E1(4)  

prtExHs4LineLen 1.3.6.1.4.1.164.3.2.3.2.7.1.1.7
This attribute is the line length parameter used only for T1 interfaces. len399p533ft=len-399-533ft
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), fcc68(7)  

prtExHs4RestoreT 1.3.6.1.4.1.164.3.2.3.2.7.1.1.8
Time passing from the disappearance of the loss of synchronization condition (red alarm), to the restoration of normal service.
OBJECT-TYPE    
  INTEGER restoreT1secFast(2), restoreT10sec62411(3), ccittE1(4)  

prtExHs4OosSig 1.3.6.1.4.1.164.3.2.3.2.7.1.1.9
Out of Service signal type.
OBJECT-TYPE    
  INTEGER notsupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtExHs4OosCode 1.3.6.1.4.1.164.3.2.3.2.7.1.1.10
OOS Code
OBJECT-TYPE    
  INTEGER notsupported(2), oosCode00H(3), oosCode1aH(4), oosCode54H(5), oosCode7eH(6), oosCode7fH(7), oosCode98H(8), oosCode9eH(9), oosCoded5H(10), oosCodee4H(11), oosCodeffH(12)  

prtExHs4IdleCode 1.3.6.1.4.1.164.3.2.3.2.7.1.1.11
Type value(00 - FF HEX), excluding 0H,8H,10H,12H,21H,24H, 42H,49H,84H,92H
OBJECT-TYPE    
  Integer32  

prtExHs4MfClkSrcSlt 1.3.6.1.4.1.164.3.2.3.2.7.1.1.12
This attribute indicates whether the port Tx is multiframe synchronized with Rx multiframe of another port and the slot position of that port. This opration is required in order to bypass signaling of PCM voice channels. When its value is Local(2) there is no meaning to 'prtExHs4MfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid
OBJECT-TYPE    
  INTEGER local(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHs4MfClkSrcPrt 1.3.6.1.4.1.164.3.2.3.2.7.1.1.13
A unique number to identify a port position in the mux if the MultiFrame clock source is valid (YES). inPrt1 - for MTML-H/E1 cards.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), inPrt1(101)  

prtExHs4TsCnfgTable 1.3.6.1.4.1.164.3.2.3.2.7.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHs4TsEntry

prtExHs4TsEntry 1.3.6.1.4.1.164.3.2.3.2.7.2.1
An entry in table.
OBJECT-TYPE    
  PrtExHs4TsEntry  

prtExHs4TsCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtExHs4TsSltIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHs4TsPrtIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.3
This attribute indicates a unique port number. Hs4/T1 and Hs4/T1 cards have only one external interface.
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExHs4TsIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.4
This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling.
OBJECT-TYPE    
  Integer32  

prtExHs4TsIConSlot 1.3.6.1.4.1.164.3.2.3.2.7.2.1.5
This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS).
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), split(100)  

prtExHs4TsIConPrt 1.3.6.1.4.1.164.3.2.3.2.7.2.1.6
This attribute indicates the internally (In Mux) connected/routed port.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), noConnect(100)  

prtExHs4TsIConTs 1.3.6.1.4.1.164.3.2.3.2.7.2.1.7
This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Module and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
OBJECT-TYPE    
  Integer32  

prtHsiCnfg 1.3.6.1.4.1.164.3.2.3.2.8
OBJECT IDENTIFIER    

prtExHsiCnfgTable 1.3.6.1.4.1.164.3.2.3.2.8.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHsiCnfgEntry

prtExHsiCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.8.1.1
An entry in table.
OBJECT-TYPE    
  PrtExHsiCnfgEntry  

prtExHsiCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.8.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExHsiSltIdx 1.3.6.1.4.1.164.3.2.3.2.8.1.1.2
This attribute indicates a unique slot position where the card is inserted.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

prtExHsiPrtIdx 1.3.6.1.4.1.164.3.2.3.2.8.1.1.3
A unique port identifier within the card. For MP : 1..12 For DXC: 111 .. 2531. See DXC R6 spec for port index convention. For FCD-A, 'S' Interface external ports: 131, 141, 151, 161.
OBJECT-TYPE    
  Integer32  

prtExHsiConnect 1.3.6.1.4.1.164.3.2.3.2.8.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. v51 - this port is connected to a V5.1 interface. All rest of the values will be 'notApplicable' in this case. V5.1 MIB will be used instead.
OBJECT-TYPE    
  INTEGER no(2), yes(3), v51(4)  

prtExHsiRate 1.3.6.1.4.1.164.3.2.3.2.8.1.1.5
This attribute indicates the port speed.
OBJECT-TYPE    
  INTEGER r600bps(2), r1200bps(3), r2400bps(4), r4800bps(5), r9600bps(6), r19200bps(7), r38400bps(8), r48kbps(9), r56kbps(10), r64kbps(11), r128kbps(12), notApplicable(255)  

prtExHsiLinkTo 1.3.6.1.4.1.164.3.2.3.2.8.1.1.6
It indicates the slot of the main link card to which the HS-? card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsiInterface 1.3.6.1.4.1.164.3.2.3.2.8.1.1.7
It indicates the interface type: lt = line termination nt = network termination te = terminal equipment. lt1 - for ASMi-31 connection (not ISDN) For MP: For HS-U/I and HS-U/1 only 'lt' and 'nt' are applicable. For HS-S , only 'te' and 'nt' are applicable. For HS-U, this object is not applicable. For HS-U6, HS-U12, are applicable: 'lt'=lt-i,'nt'=nt-i, lt1. For DXC: For HS-U8, HS-U16, are applicable: 'lt'=LT-I,'nt'=NT-I, 'lt1'=LT-1.
OBJECT-TYPE    
  INTEGER lt(1), nt(2), te(3), lt1(4), notApplicable(255)  

prtExHsiActType 1.3.6.1.4.1.164.3.2.3.2.8.1.1.8
It indicates the Activation Type. Activation Type is the Synchronization type towards the PBX. It is applicable only when prtExHsiInterface=nt. notApplicable - for cards that do not support this object, or when prtExHsiInterface is NOT nt.
OBJECT-TYPE    
  INTEGER notApplicable(1), type1(2), type2(3), type3(4)  

prtInHsiCnfgTable 1.3.6.1.4.1.164.3.2.3.2.8.2
The write operation into the Table Objects is valid only to the TmpCnfg entry. This table is not applicable for MP-2100 HS-U card type.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInHsiCnfgEntry

prtInHsiCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.8.2.1
An entry in table.
OBJECT-TYPE    
  PrtInHsiCnfgEntry  

prtInHsiCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.8.2.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtInHsiSltIdx 1.3.6.1.4.1.164.3.2.3.2.8.2.1.2
This object indicates a unique slot position where the card is inserted.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

prtInHsiPrtIdx 1.3.6.1.4.1.164.3.2.3.2.8.2.1.3
A unique port identifier within the card. Valid values for MP: inPrt1 (101) .. inPrt48 (148). Valid values for DXC: 11012.. 25316. See DXC R6 spec for port index convention.
OBJECT-TYPE    
  Integer32  

prtInHsiConnect 1.3.6.1.4.1.164.3.2.3.2.8.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInHsiRate 1.3.6.1.4.1.164.3.2.3.2.8.2.1.5
This object indicates the port speed. For HS-U/I and HS-S ports: 2 bit - up to 9600bps 4 bit - 19200bps 8 bit - 38400bps .. 64kbps. concentrated - this D channel goes to a Concentration channel, that represents many channels that this value was selected for them. The Concentrated channel is an Internal D Channel of the same card. This value is applicable only for D channels, except Concentration channel itself. --for HS-S and HS-U/I cards the Concentration channel will always be: internal-13 --for MP-2200 HS-S12, HS-S6, HS-U12, HS-U6 and DXC HS-U8 and HS-U16 cards, the Concentration channel is selected via the prtInHsiConcentratedTo object. notConnected - same as prtInHsiConnect=no.
OBJECT-TYPE    
  INTEGER r600bps(2), r1200bps(3), r2400bps(4), r4800bps(5), r9600bps(6), r19200bps(7), r38400bps(8), r48kbps(9), r56kbps(10), r64kbps(11), r128kbps(12), concentrated(13), notConnected(100), notApplicable(255)  

prtInHsiConcentratedTo 1.3.6.1.4.1.164.3.2.3.2.8.2.1.6
The Concentration D Channel of the prtInHsiPrtIdx port. The port always belongs to the same card as prtInHsiPrtIdx port. This object is applicable only when prtInHsiRate=concentrated. Valid values: - notApplicable: 255 - for MP-2200: HS-S12, HS-U12 cards: inPrt37 (137) .. inPrt48 (148). HS-S6, HS-U6 cards: inPrt19 (119) .. inPrt24 (124). - for DXC: HS-U8 cards: 112 .. 254 HS-U16 cards: 112 .. 258. See DXC R6 spec for port index convention.
OBJECT-TYPE    
  Integer32  

prtPVc4Cnfg 1.3.6.1.4.1.164.3.2.3.2.9
OBJECT IDENTIFIER    

prtExPVc4CnfgTable 1.3.6.1.4.1.164.3.2.3.2.9.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPVc4CnfgEntry

prtExPVc4CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.9.1.1
An entry in table.
OBJECT-TYPE    
  PrtExPVc4CnfgEntry  

prtExPVc4CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExPVc4SltIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.2
This attribute indicates a unique slot position where the card is inserted.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPVc4PrtIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.3
This object indicates the port number in the selected card (slot).
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108)  

prtExPVc4PrtType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.4
This object indicates the type of the selected port. In Mx 30/300 phase 4: s0 & u are for Voice over ISDN. In MX 30/300 phase 5: sQsig & uQsig are used for Voice over ISDN with Qsig option. In MX MVC4 voice cards, each pair of ports 1-2, 3-4 may have a different type: E&M, FXO, FXS. In MVC4 compressed voice cards ports 1..4 have the same interface for all ports. In MVC8 compressed voice cards each group of ports 1..4, 5..8 may have a different type: E&M, FXO, FXS.
OBJECT-TYPE    
  INTEGER eAndM(1), fxo(2), fxs(3), internal(4), s0(5), u(6), sQsig(7), uQsig(8)  

prtExPVc4Connect 1.3.6.1.4.1.164.3.2.3.2.9.1.1.5
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPVc4IfType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.6
This attribute indicates the interface type of the port. eAndM4wires and eAndM2wires - are valid only for E&M port type eAndM4wires - means 2/4 wires fxoGnd and fxoLoop - are valid only for FXO port type fxsGnd and fxsLoop - are valid only for FXS port type e1Framer, e1Slave, t1Framer, t1Slave - are applicable for the mvc4Pbx cards only.
OBJECT-TYPE    
  INTEGER unknown(1), eAndM4wires(2), eAndM2wires(3), fxoGnd(4), fxoLoop(5), fxsGnd(6), fxsLoop(7), e1Framer(8), e1Slave(9), t1Framer(10), t1Slave(11)  

prtExPVc4TxGain 1.3.6.1.4.1.164.3.2.3.2.9.1.1.7
Transmission gain in dBm.
OBJECT-TYPE    
  Integer32  

prtExPVc4RxGain 1.3.6.1.4.1.164.3.2.3.2.9.1.1.8
Reception gain in dBm.
OBJECT-TYPE    
  Integer32  

prtExPVc4MaxRate 1.3.6.1.4.1.164.3.2.3.2.9.1.1.9
Voice rate.
OBJECT-TYPE    
  INTEGER notConnected(1), r4800bps(2), r7200bps(3), r9600bps(4), notApplicatble(255)  

prtExPVc4Tc 1.3.6.1.4.1.164.3.2.3.2.9.1.1.10
Time interval for CIR control, in seconds. The value will be the same for all cards' ports.
OBJECT-TYPE    
  INTEGER t1sec(1), t2sec(2), t3sec(3), t4sec(4)  

prtExPVc4Oos 1.3.6.1.4.1.164.3.2.3.2.9.1.1.11
Handling type, when connection is lost.
OBJECT-TYPE    
  INTEGER notSupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtExPVc4EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.9.1.1.12
Echo canceler activation.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtExPVc4VarDelay 1.3.6.1.4.1.164.3.2.3.2.9.1.1.13
Maximum variant delay of the FR network, in msec.
OBJECT-TYPE    
  Integer32 0..300  

prtExPVc4CongLevel 1.3.6.1.4.1.164.3.2.3.2.9.1.1.14
This object indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5%.
OBJECT-TYPE    
  Integer32 0..70  

prtExPVc4Wire 1.3.6.1.4.1.164.3.2.3.2.9.1.1.15
This object indicates the wiring of the E&M port. It is applicable only for E&M card type.
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2), notApplicable(255)  

prtExPVc4ExtensionType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.16
This object indicates the type of extension relevant for this port. ipForceConnect (6) is used for automatic connection or automatic dialing when the phone is off hook (hot line). permanentDial (7) means that the call is established upon power up. The hook may be on or off. Permanent Dialing can be used when there is no signaling. autoAccept (8) means that the called party in the Permanent Dialing will accept the call from the remote side automatically upon on or off hook.
OBJECT-TYPE    
  INTEGER notApplicable(1), forceConnect(2), voiceSwitching(3), transparent(4), transparentPlus(5), ipForceConnect(6), permanentDial(7), autoAccept(8)  

prtExPVc4ExtensionNumber 1.3.6.1.4.1.164.3.2.3.2.9.1.1.17
This is the extension number of this port. This field is relevant only when the extension type is voice switching and is read only if the port is member of a hunt group.
OBJECT-TYPE    
  DisplayString SIZE(2)  

prtExPVc4OutPulsing 1.3.6.1.4.1.164.3.2.3.2.9.1.1.18
This field indicates whether to outpulse the received digits. It is notApplicable(1) when the extension type is forceConnect(2).
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4HuntGroupMb 1.3.6.1.4.1.164.3.2.3.2.9.1.1.19
This object indicates if this port belongs to an hunt group.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4HuntGroupIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.20
If it belongs to an hunt group, this fields indicates the index of the relevant hunt group. 0 = notApplicable
OBJECT-TYPE    
  Integer32 0..10  

prtExPVc4AutoFaxMode 1.3.6.1.4.1.164.3.2.3.2.9.1.1.21
This object indicates if the system will switch automatically to FAX mode when detecting FAX activity. Default=Yes.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4FaxRate 1.3.6.1.4.1.164.3.2.3.2.9.1.1.22
FAX initial rate. Default=9600 bps.
OBJECT-TYPE    
  INTEGER notConnected(1), r4800bps(2), r7200bps(3), r9600bps(4), r12000bps(5), r14400bps(6), r2400bps(7)  

prtExPVc4SeizeAck 1.3.6.1.4.1.164.3.2.3.2.9.1.1.23
This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Example: If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook) from the PBX it will send an Off Hook to the PBX. The Seize Parameter is relevant for all the following cards: MVC-4 MVC-4/E1-Framer MVC-4/T1-DSU-Framer MVC-4/T1-CSU-Framer MVC-4/E1-SLAVE MVC-4/T1-SLAVE Default values: Analog FXS - No (value can't be changed). Analog FXO - Yes (value can't be changed). Analog E&M - No (values NO/YES). Digital E1/T1 Framer & Slave - No.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPVc4SignalingProtocol 1.3.6.1.4.1.164.3.2.3.2.9.1.1.24
The signaling protocol that will be used between the PABX & the voice port. Delay Start Protocol: the line is seized by sending an Off hook signal and after a delay, if the called party is available (On hook) DTMF (Dual Tone Multi Frequency) digits are sent towards the called party. Immediate Start Protocol: the line is seized by sending an Off Hook signal and immediately DTMF digits are sent towards the called party. Wink start protocol: the line is seized by sending an Off Hook signal and then the called party sends a short Off Hook wink signal. Now the calling party starts sending DTMF digits.
OBJECT-TYPE    
  INTEGER delayStart(2), immediateStart(3), winkStart(4)  

prtExPVc4DelayStart 1.3.6.1.4.1.164.3.2.3.2.9.1.1.25
This parameter is used only for Delay Protocol. This is the time that the calling party will wait after sending an Off hook signal and before sending DTMF digits to the called party. The delay values are 100..5000 msec in intervals of 100 msec.
OBJECT-TYPE    
  Integer32  

prtExPVc4WinkMinDuration 1.3.6.1.4.1.164.3.2.3.2.9.1.1.26
This parameter is used only for Wink Protocol. Min Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec.
OBJECT-TYPE    
  Integer32  

prtExPVc4WinkMaxDuration 1.3.6.1.4.1.164.3.2.3.2.9.1.1.27
This parameter is used only for Wink Protocol. Max Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec.
OBJECT-TYPE    
  Integer32  

prtExPVc4GenerateTone 1.3.6.1.4.1.164.3.2.3.2.9.1.1.28
This parameter indicates whether the device (MX or MPH) should generate dial tones for the channel. If the value is yes (3), it generates dial tones. If the value is no (2), the connected equipment will generate dial tones. For example for some ISDN sets the dial tone is generated by the phone itself while for others sets it is generated by the MX.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4CodingLaw 1.3.6.1.4.1.164.3.2.3.2.9.1.1.29
This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations
OBJECT-TYPE    
  INTEGER aLAW(1), uLAW(2)  

prtExPVc4GenerateRingBack 1.3.6.1.4.1.164.3.2.3.2.9.1.1.30
Determines whether the Ring Back tone is generated locally or from the remote end. The default is - NO (Meaning coming from the remote end). Yes means that the Ring Back Tone is generated locally. Applicable only for Force Connect.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4ChannelId 1.3.6.1.4.1.164.3.2.3.2.9.1.1.31
Channel Identifier. According to FRF11 each voice port that works as force connect should add a CH Id after the DLCI in the frame header. Default : 1 Applicable only for Force Connect. Not Applicable value will be 0.
OBJECT-TYPE    
  Integer32 0..256  

prtExPVc4PortConnection 1.3.6.1.4.1.164.3.2.3.2.9.1.1.32
Port connection determines whether the port is connected to a PABX (Trunk) or to Telephone set (Line) . It determines whether to send certain messages to the port or not. If the type is LINE then the port generates a ring back tone , if TRUNK it doesn't (The PBX does it).
OBJECT-TYPE    
  INTEGER notApplicable(1), line(2), trunk(3)  

prtExPVc4CoderAndRate 1.3.6.1.4.1.164.3.2.3.2.9.1.1.33
Coder and Rate for the Voice Compression. Relevant for MVC-8 card only.
OBJECT-TYPE    
  INTEGER notApplicable(1), g7231r6300BPS(2), g7231r5300BPS(3), g729A8KBPS(4), g711aLAW(5), g711uLAW(6), g726r16KBPS(7), g726r24KBPS(8), g726r32KBPS(9), g726r40KBPS(10), g727r16KBPS(11), g727r24r16KBPS(12), g727r24KBPS(13), g727r16r32KBPS(14), g727r32r24KBPS(15), g727r32KBPS(16), g727r40r16KBPS(17), g727r40r24KBPS(18), g727r40r32KBPS(19), transparent(20), netcoder6400BPS(21), netcoder7200BPS(22), netcoder8KBPS(23), netcoder8800BPS(24), netcoder9600BPS(25)  

prtExPVc4DestinationNum 1.3.6.1.4.1.164.3.2.3.2.9.1.1.34
The destination phone number: 0 to 22 digits. Applicable for Auto Dial - ipForceConnect(6), Permanent Dial and Auto Accept Extension Types. Default: Null String
OBJECT-TYPE    
  DisplayString  

prtExPVc4DtmfRelay 1.3.6.1.4.1.164.3.2.3.2.9.1.1.35
When DTMF RELAY is disabled, the DTMF digits (dialed by the user) are transmitted as compressed voice and in the remote unit are decompressed. When DTMF RELAY is enabled, the DTMF digits are detected at the near side and not transmitted as voice. Instead, only an indication of what digits were dialed are transmitted and in the far end the tone is regenerated.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

prtExPVc4DiscOnSilence 1.3.6.1.4.1.164.3.2.3.2.9.1.1.36
No. of silenced seconds after which the call will be disconected. A value of 0 means that there will be no disconnect when there is silence. Possible values: 0 - 900 sec.
OBJECT-TYPE    
  Integer32  

prtExPVc4DynamicJitter 1.3.6.1.4.1.164.3.2.3.2.9.1.1.37
The MVC8 uses two mechanisms to overcome the network delay. The first one is a static jitter buffer which holds a constant buffer of up to 300 Msec and can be controled by the JITTER parameter (prtExPVc4VarDelay). The second one is the dynamic jitter which calculates, in real time, the network delay and handles a jitter buffer dynamically. The dynamic mechanism that is implemented in MVC8, was intended to overcome network delay yet when the network bursts, the MVC8 dynamic mechanism is not able to overcome the delay. Therefore it is better not to use the dynamic jitter (DISABLE - should be the default) where bursts may occur often.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

prtExPVc4EandMType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.38
This is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters.
OBJECT-TYPE    
  INTEGER notApplicable(1), type1(2), type2(3), type3(4), ssdc5(5)  

prtExPVc4DlciTable 1.3.6.1.4.1.164.3.2.3.2.9.2
The write operation into the Table Objects is valid only at the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPVc4DlciEntry

prtExPVc4DlciEntry 1.3.6.1.4.1.164.3.2.3.2.9.2.1
An entry in table.
OBJECT-TYPE    
  PrtExPVc4DlciEntry  

prtExPVc4DlciCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.9.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtExPVc4DlciSltIdx 1.3.6.1.4.1.164.3.2.3.2.9.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPVc4DlciPrtIdx 1.3.6.1.4.1.164.3.2.3.2.9.2.1.3
This attribute indicates a unique internal port number. VC4 cards have four external ports.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4)  

prtExPVc4DlciValid 1.3.6.1.4.1.164.3.2.3.2.9.2.1.4
This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPVc4DlciIConSlt 1.3.6.1.4.1.164.3.2.3.2.9.2.1.5
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPVc4DlciIConPrt 1.3.6.1.4.1.164.3.2.3.2.9.2.1.6
This attribute indicates a unique port id which the dlci is routed to.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

prtExPVc4DlciIConDlci 1.3.6.1.4.1.164.3.2.3.2.9.2.1.7
This attribute indicates a unique internal connection dlci number, the dlci is routed to.
OBJECT-TYPE    
  Integer32 1..991  

prtExPVc4DlciTxBc 1.3.6.1.4.1.164.3.2.3.2.9.2.1.8
This attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line).
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc9600bps(3), txBc14400bps(4), txBc19200bps(5), txBc28800bps(6), txBc32000bps(7), txBc38400bps(8), txBc48000bps(9), txBc56000bps(10), txBc57600bps(11), txBc64Kbps(12), txBc128Kbps(13), txBc192Kbps(14), txBc256Kbps(15), txBc320Kbps(16), txBc384Kbps(17), txBc448Kbps(18), txBc512Kbps(19), txBc768Kbps(20), txBc1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPVc4DlciTxBe 1.3.6.1.4.1.164.3.2.3.2.9.2.1.9
This attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line).
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe9600bps(3), txBe14400bps(4), txBe19200bps(5), txBe28800bps(6), txBe32000bps(7), txBe38400bps(8), txBe48000bps(9), txBe56000bps(10), txBe57600bps(11), txBe64Kbps(12), txBe128Kbps(13), txBe192Kbps(14), txBe256Kbps(15), txBe320Kbps(16), txBe384Kbps(17), txBe448Kbps(18), txBe512Kbps(19), txBe768Kbps(20), txBe1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPVc4DlciRxBc 1.3.6.1.4.1.164.3.2.3.2.9.2.1.10
This attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line).
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc9600bps(3), rxBc14400bps(4), rxBc19200bps(5), rxBc28800bps(6), rxBc32000bps(7), rxBc38400bps(8), rxBc48000bps(9), rxBc56000bps(10), rxBc57600bps(11), rxBc64Kbps(12), rxBc128Kbps(13), rxBc192Kbps(14), rxBc256Kbps(15), rxBc320Kbps(16), rxBc384Kbps(17), rxBc448Kbps(18), rxBc512Kbps(19), rxBc768Kbps(20), rxBc1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPVc4DlciRxBe 1.3.6.1.4.1.164.3.2.3.2.9.2.1.11
This attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line).
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe9600bps(3), rxBe14400bps(4), rxBe19200bps(5), rxBe28800bps(6), rxBe32000bps(7), rxBe38400bps(8), rxBe48000bps(9), rxBe56000bps(10), rxBe57600bps(11), rxBe64Kbps(12), rxBe128Kbps(13), rxBe192Kbps(14), rxBe256Kbps(15), rxBe320Kbps(16), rxBe384Kbps(17), rxBe448Kbps(18), rxBe512Kbps(19), rxBe768Kbps(20), rxBe1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPVc4DlciPriority 1.3.6.1.4.1.164.3.2.3.2.9.2.1.12
This attribute indicates a unique priority of the pvc. 6 is the lowest priority and 8 is the highest priority.
OBJECT-TYPE    
  Integer32 6..8  

prtExPVc4DlciStatus 1.3.6.1.4.1.164.3.2.3.2.9.2.1.13
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

prtHsrCnfg 1.3.6.1.4.1.164.3.2.3.2.10
OBJECT IDENTIFIER    

prtExHsrCnfgTable 1.3.6.1.4.1.164.3.2.3.2.10.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHsrCnfgEntry

prtExHsrCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.10.1.1
An entry in table.
OBJECT-TYPE    
  PrtExHsrCnfgEntry  

prtExHsrCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.10.1.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExHsrSltIdx 1.3.6.1.4.1.164.3.2.3.2.10.1.1.2
This object indicates a unique slot position where the card is inserted.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19)  

prtExHsrPrtIdx 1.3.6.1.4.1.164.3.2.3.2.10.1.1.3
A unique prt identifier within the card. Valid values: For MP: - For HS-R cards: exPrt1 (1) .. exPrt4 (4) - For HS-U/1 cards: inPrt1 (101) .. inPrt4 (104) - For HS-S12, HS-S6, HS-U12, HS-U6 cards: exPrt1 (1) .. exPrt12 (12). This MIB table is used only for LT-1 interface. For DXC: - For HS-U8, HS-U16 cards: 111 .. 2531 (See DXC R6 spec for port index convention). This MIB table is used only for LT-1 interface.
OBJECT-TYPE    
  Integer32  

prtExHsrConnect 1.3.6.1.4.1.164.3.2.3.2.10.1.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExHsrProtocol 1.3.6.1.4.1.164.3.2.3.2.10.1.1.5
This object indicates the protocol.
OBJECT-TYPE    
  INTEGER sync(2), async(3)  

prtExHsrRate 1.3.6.1.4.1.164.3.2.3.2.10.1.1.6
This object indicates the port speed. The 16,32,48,56,64 and 128 kbps rates are applicable only for Sync protocol. The 57.6 and 115.2 kbps rates are applicable only for Async protocol. notConnected= 0 rate.
OBJECT-TYPE    
  INTEGER r600bps(2), r1200bps(3), r2400bps(4), r4800bps(5), r9600bps(6), r19200bps(7), r38400bps(8), r48kbps(9), r56kbps(10), r64kbps(11), r16000bps(12), r32000bps(13), r57600bps(14), r115200bps(15), r128000bps(16), notConnected(100)  

prtExHsrDataBits 1.3.6.1.4.1.164.3.2.3.2.10.1.1.7
Data Bits. This object is applicable for Async protocol only.
OBJECT-TYPE    
  INTEGER d5bits(1), d6bits(2), d7bits(3), d8bits(4), notApplicable(255)  

prtExHsrParity 1.3.6.1.4.1.164.3.2.3.2.10.1.1.8
- For HS-R card, this object indicates if the parity bit is needed or not. Therefore, the 'no' and 'yes; values are applicable. - For HS-S12, HS-U12, the parity type is selected: no, odd, even. This object is applicable for Async protocol only.
OBJECT-TYPE    
  INTEGER no(2), yes(3), odd(4), even(5), notApplicable(255)  

prtExHsrStopBits 1.3.6.1.4.1.164.3.2.3.2.10.1.1.9
This object indicates the minimum number of stop bits in the tx async frame. This object is applicable for Async protocol only.
OBJECT-TYPE    
  INTEGER stopBits1Bit(1), stopBits2Bits(2), notApplicable(255)  

prtExHsrCts 1.3.6.1.4.1.164.3.2.3.2.10.1.1.10
CTS. This object is applicable for Async protocol only.
OBJECT-TYPE    
  INTEGER on(2), rts(3), notApplicable(255)  

prtExHsrClkMode 1.3.6.1.4.1.164.3.2.3.2.10.1.1.11
Clock mode. This object is applicable for Sync protocol only.
OBJECT-TYPE    
  INTEGER dce(1), extDce(2), notApplicable(255)  

prtExHsrLinkTo 1.3.6.1.4.1.164.3.2.3.2.10.1.1.12
It indicates the slot of the main link card to which the HS-R card is mapped. notApplicable - for HS-U/1 internal ports. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsrDcdDsr 1.3.6.1.4.1.164.3.2.3.2.10.1.1.13
DCD & DSR.
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), endToEnd(3)  

prtExHsrOperMode 1.3.6.1.4.1.164.3.2.3.2.10.1.1.14
This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request.
OBJECT-TYPE    
  INTEGER normal(2), unidirectRx(3), broadcast(4)  

prtExHsrRtsDtr 1.3.6.1.4.1.164.3.2.3.2.10.1.1.15
RTS & DTR.
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), endToEnd(3)  

prtExHsrLlbEnable 1.3.6.1.4.1.164.3.2.3.2.10.1.1.16
Enable/Disable LLB.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtExHsrRlbEnable 1.3.6.1.4.1.164.3.2.3.2.10.1.1.17
Enable/Disable RLB.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtExHsrRateAdapt 1.3.6.1.4.1.164.3.2.3.2.10.1.1.18
Rate Adaptation - takes a low rate and adapts it to 64Kbps. This object specifies the means this adaptation is done by.
OBJECT-TYPE    
  INTEGER notApplicable(1), proprietary(2), v110(3)  

prtExHsrRemoteModem 1.3.6.1.4.1.164.3.2.3.2.10.1.1.19
Remote modem. asmi31s2 = ASMi-31/2
OBJECT-TYPE    
  INTEGER notApplicable(1), asmi31(2), asmi31s2(3)  

prtMbeCnfg 1.3.6.1.4.1.164.3.2.3.2.11
OBJECT IDENTIFIER    

prtExMbeCnfgTable 1.3.6.1.4.1.164.3.2.3.2.11.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExMbeCnfgEntry

prtExMbeCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.11.1.1
An entry in table.
OBJECT-TYPE    
  PrtExMbeCnfgEntry  

prtExMbeCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.11.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExMbeSltIdx 1.3.6.1.4.1.164.3.2.3.2.11.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExMbePrtIdx 1.3.6.1.4.1.164.3.2.3.2.11.1.1.3
A unique port identifier within the card.
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExMbeLan 1.3.6.1.4.1.164.3.2.3.2.11.1.1.4
This attribute indicates whether the MBE port is operated as main or remote bridge.
OBJECT-TYPE    
  INTEGER remote(1), main(2)  

prtInMbeCnfgTable 1.3.6.1.4.1.164.3.2.3.2.11.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInMbeCnfgEntry

prtInMbeCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.11.2.1
An entry in table.
OBJECT-TYPE    
  PrtInMbeCnfgEntry  

prtInMbeCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.11.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtInMbeSltIdx 1.3.6.1.4.1.164.3.2.3.2.11.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInMbePrtIdx 1.3.6.1.4.1.164.3.2.3.2.11.2.1.3
A unique port identifier within the card.
OBJECT-TYPE    
  INTEGER inPrt1(101)  

prtInMbeConnect 1.3.6.1.4.1.164.3.2.3.2.11.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInMbeRate 1.3.6.1.4.1.164.3.2.3.2.11.2.1.5
This attribute indicates the port speed.
OBJECT-TYPE    
  INTEGER r1x64eq64Kbps(1), r2x64eq128Kbps(2), r3x64eq192Kbps(3), r4x64eq256Kbps(4), r5x64eq320Kbps(5), r6x64eq384Kbps(6), r7x64eq448Kbps(7), r8x64eq512Kbps(8), r9x64eq576Kbps(9), r10x64eq640Kbps(10), r11x64eq704Kbps(11), r12x64eq768Kbps(12), r13x64eq832Kbps(13), r14x64eq896Kbps(14), r15x64eq960Kbps(15), r16x64eq1024Kbps(16), r17x64eq1088Kbps(17), r18x64eq1152Kbps(18), r19x64eq1216Kbps(19), r20x64eq1280Kbps(20), r21x64eq1344Kbps(21), r22x64eq1408Kbps(22), r23x64eq1472Kbps(23), r24x64eq1536Kbps(24)  

prtInMbeLinkTo 1.3.6.1.4.1.164.3.2.3.2.11.2.1.6
It indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtTreCnfg 1.3.6.1.4.1.164.3.2.3.2.12
OBJECT IDENTIFIER    

prtExTreCnfgTable 1.3.6.1.4.1.164.3.2.3.2.12.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExTreCnfgEntry

prtExTreCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.12.1.1
An entry in table.
OBJECT-TYPE    
  PrtExTreCnfgEntry  

prtExTreCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.12.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExTreSltIdx 1.3.6.1.4.1.164.3.2.3.2.12.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExTrePrtIdx 1.3.6.1.4.1.164.3.2.3.2.12.1.1.3
A unique port identifier within the card.
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExTreLan 1.3.6.1.4.1.164.3.2.3.2.12.1.1.4
This attribute indicates whether the TRE port is operated as main or remote bridge. Default=remote.
OBJECT-TYPE    
  INTEGER remote(1), main(2)  

prtExTreLanRate 1.3.6.1.4.1.164.3.2.3.2.12.1.1.5
This attribute indicates the Rate of the TRE port in Mbit/sec. Default-r4M.
OBJECT-TYPE    
  INTEGER r4M(1), r16M(2)  

prtInTreCnfgTable 1.3.6.1.4.1.164.3.2.3.2.12.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInTreCnfgEntry

prtInTreCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.12.2.1
An entry in table.
OBJECT-TYPE    
  PrtInTreCnfgEntry  

prtInTreCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.12.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtInTreSltIdx 1.3.6.1.4.1.164.3.2.3.2.12.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInTrePrtIdx 1.3.6.1.4.1.164.3.2.3.2.12.2.1.3
A unique port identifier within the card.
OBJECT-TYPE    
  INTEGER inPrt1(101)  

prtInTreConnect 1.3.6.1.4.1.164.3.2.3.2.12.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInTreRate 1.3.6.1.4.1.164.3.2.3.2.12.2.1.5
This attribute indicates the port speed.
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17)  

prtInTreLinkTo 1.3.6.1.4.1.164.3.2.3.2.12.2.1.6
It indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtLs6Cnfg 1.3.6.1.4.1.164.3.2.3.2.13
OBJECT IDENTIFIER    

prtExLs6CnfgTable 1.3.6.1.4.1.164.3.2.3.2.13.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExLs6CnfgEntry

prtExLs6CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.13.1.1
An entry in table.
OBJECT-TYPE    
  PrtExLs6CnfgEntry  

prtExLs6CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.13.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExLs6SltIdx 1.3.6.1.4.1.164.3.2.3.2.13.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExLs6PrtIdx 1.3.6.1.4.1.164.3.2.3.2.13.1.1.3
This attribute indicates a unique port index.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtExLs6Connect 1.3.6.1.4.1.164.3.2.3.2.13.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExLs6Protocol 1.3.6.1.4.1.164.3.2.3.2.13.1.1.5
This attribute indicates the protocol. async - can be selected only for ports 1-2.
OBJECT-TYPE    
  INTEGER sync(2), async(3)  

prtExLs6Rate 1.3.6.1.4.1.164.3.2.3.2.13.1.1.6
Port rates in bps. g1 - contains the values : (2)-(6),(9),(12),(16) g2 - contains the values : (7),(10),(14),(19) g3 - contains the values : (8),(11),(13),(15),(17),(18),(20); it is not applicable when using Async protocol. Rates of pair ports (1-2, 3-4, 5-6) must be from the same group.
OBJECT-TYPE    
  INTEGER r300bps(2), r600bps(3), r1200bps(4), r2400bps(5), r4800bps(6), r7200bps(7), r8000bps(8), r9600bps(9), r14400bps(10), r16000bps(11), r19200bps(12), r24000bps(13), r28800bps(14), r32000bps(15), r38400bps(16), r48000bps(17), r56000bps(18), r57600bps(19), r64000bps(20)  

prtExLs6ClkMode 1.3.6.1.4.1.164.3.2.3.2.13.1.1.7
This attribute indicates a unique port operation clock mode. It is applicable for Sync protocol only .
OBJECT-TYPE    
  INTEGER dce(1), extDce(2), dte1(3), notApplicable(255)  

prtExLs6CtrlSignal 1.3.6.1.4.1.164.3.2.3.2.13.1.1.8
Control Signal.
OBJECT-TYPE    
  INTEGER local(2), rts(3), dtrAndRts(4)  

prtExLs6DataBits 1.3.6.1.4.1.164.3.2.3.2.13.1.1.9
Data Bits. This object is applicable for Async protocol only.
OBJECT-TYPE    
  INTEGER d6bits(1), d7bits(2), d8bits(3), d9bits(4), notApplicable(255)  

prtExLs6Cts 1.3.6.1.4.1.164.3.2.3.2.13.1.1.10
This object indicates the CTS control line operation mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3)  

prtExLs6LinkToInternal 1.3.6.1.4.1.164.3.2.3.2.13.1.1.11
This object indicates which internal port of the card, the external port is linked to.
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102), notApplicable(255)  

prtExLs6VCnfgTable 1.3.6.1.4.1.164.3.2.3.2.13.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExLs6VCnfgEntry

prtExLs6VCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.13.2.1
An entry in table.
OBJECT-TYPE    
  PrtExLs6VCnfgEntry  

prtExLs6VCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.13.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExLs6VSltIdx 1.3.6.1.4.1.164.3.2.3.2.13.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExLs6VPrtIdx 1.3.6.1.4.1.164.3.2.3.2.13.2.1.3
A unique identifier of the port, within the card.
OBJECT-TYPE    
  INTEGER exPrt7(7), exPrt8(8)  

prtExLs6VConnect 1.3.6.1.4.1.164.3.2.3.2.13.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExLs6VRate 1.3.6.1.4.1.164.3.2.3.2.13.2.1.5
Rate (bps) used for FAX transmission and Voice coding.
OBJECT-TYPE    
  INTEGER r6400bps(2), r7200bps(3), r8000bps(4), r9600bps(5), r16000bps(6), r24000bps(7), r32000bps(8), r64000bps(9)  

prtExLs6VEchoCanceler 1.3.6.1.4.1.164.3.2.3.2.13.2.1.6
Echo canceler activation.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtExLs6VIfType 1.3.6.1.4.1.164.3.2.3.2.13.2.1.7
This attribute indicates the interface type of the port. w4wire - is applicable only for E&M port type.
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2)  

prtExLs6VTxGain 1.3.6.1.4.1.164.3.2.3.2.13.2.1.8
Transmit gain in dBm. E&M - values range: -17 .. 8 FXO - values range: -16 .. 4 FXS - values range: -13 .. 8
OBJECT-TYPE    
  Integer32  

prtExLs6VRxGain 1.3.6.1.4.1.164.3.2.3.2.13.2.1.9
Receive gain in dBm. E&M - values range: -17 .. 2 FXO - values range: -17 .. -1 FXS - values range: -17 .. 2
OBJECT-TYPE    
  Integer32  

prtExLs6VOos 1.3.6.1.4.1.164.3.2.3.2.13.2.1.10
Out of Service signaling mode.
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2), busyIdle(3), idleBusy(4)  

prtInLs6CnfgTable 1.3.6.1.4.1.164.3.2.3.2.13.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInLs6CnfgEntry

prtInLs6CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.13.3.1
An entry in table.
OBJECT-TYPE    
  PrtInLs6CnfgEntry  

prtInLs6CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.13.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtInLs6SltIdx 1.3.6.1.4.1.164.3.2.3.2.13.3.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInLs6PrtIdx 1.3.6.1.4.1.164.3.2.3.2.13.3.1.3
This attribute indicates a unique internal port index.
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102)  

prtInLs6Connect 1.3.6.1.4.1.164.3.2.3.2.13.3.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInLs6TandemMode 1.3.6.1.4.1.164.3.2.3.2.13.3.1.5
This object indicates the Tandem Mode. tandemSlave - is valid only for an LS-6 card having on the (current slot-1) an LS-6 card with 'tandemMaster' mode.
OBJECT-TYPE    
  INTEGER noTandem(1), tandemMaster(2), tandemSlave(3)  

prtInLs6Rate 1.3.6.1.4.1.164.3.2.3.2.13.3.1.6
Main Rate in Kbps.
OBJECT-TYPE    
  INTEGER r32Kbps(1), r56Kbps(2), r64Kpbs(3), r128Kbps(4), r256Kbps(5), r384Kbps(6), r192Kbps(7), r512Kbps(8), r768Kbps(9), r14400bps(10)  

prtInLs6RemoteType 1.3.6.1.4.1.164.3.2.3.2.13.3.1.7
Remote Type. notApplicable - when prtInLs6TandemMode=tandemSlave
OBJECT-TYPE    
  INTEGER ls6(1), km2kSlave(2), km2kStandalone(3), notApplicable(255)  

prtInLs6LinkTo 1.3.6.1.4.1.164.3.2.3.2.13.3.1.8
It indicates the slot of the main link card to which the Ls6 card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - when prtInLs6TandemMode=tandemSlave. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtVc3Cnfg 1.3.6.1.4.1.164.3.2.3.2.14
OBJECT IDENTIFIER    

prtExVc3CnfgTable 1.3.6.1.4.1.164.3.2.3.2.14.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExVc3CnfgEntry

prtExVc3CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.14.1.1
An entry in table.
OBJECT-TYPE    
  PrtExVc3CnfgEntry  

prtExVc3CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.14.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExVc3SltIdx 1.3.6.1.4.1.164.3.2.3.2.14.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVc3PrtIdx 1.3.6.1.4.1.164.3.2.3.2.14.1.1.3
A unique identifier of the port, within the card.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3)  

prtExVc3Connect 1.3.6.1.4.1.164.3.2.3.2.14.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExVc3TransGain 1.3.6.1.4.1.164.3.2.3.2.14.1.1.5
Transmit gain in dBm.
OBJECT-TYPE    
  Integer32  

prtExVc3ReceiveGain 1.3.6.1.4.1.164.3.2.3.2.14.1.1.6
Receive gain in dBm.
OBJECT-TYPE    
  Integer32  

prtExVc3Wire 1.3.6.1.4.1.164.3.2.3.2.14.1.1.7
This object is equal for all the ports in the specific card because of HW limitations
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2)  

prtExVc3Rate 1.3.6.1.4.1.164.3.2.3.2.14.1.1.8
Rate in bps.
OBJECT-TYPE    
  INTEGER r9600bps(1), r4800bps(2)  

prtExVc3EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.14.1.1.9
Echo canceler activation. The value will be the same for all the card's external ports.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtInVc3CnfgTable 1.3.6.1.4.1.164.3.2.3.2.14.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInVc3CnfgEntry

prtInVc3CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.14.2.1
An entry in table.
OBJECT-TYPE    
  PrtInVc3CnfgEntry  

prtInVc3CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.14.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtInVc3SltIdx 1.3.6.1.4.1.164.3.2.3.2.14.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInVc3PrtIdx 1.3.6.1.4.1.164.3.2.3.2.14.2.1.3
A unique identifier of the port, within the card.
OBJECT-TYPE    
  INTEGER inPrt1(101)  

prtInVc3Connect 1.3.6.1.4.1.164.3.2.3.2.14.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInVc3Rate 1.3.6.1.4.1.164.3.2.3.2.14.2.1.5
Rate in bps.
OBJECT-TYPE    
  INTEGER r32000bps(1), r16000bps(2)  

prtInVc3Oos 1.3.6.1.4.1.164.3.2.3.2.14.2.1.6
This object is equal for all the ports in the specific card because of HW limitations
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2), busyIdle(3), idleBusy(4)  

prtInVc3LinkTo 1.3.6.1.4.1.164.3.2.3.2.14.2.1.7
This attribute indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtVcPbxCnfg 1.3.6.1.4.1.164.3.2.3.2.15
OBJECT IDENTIFIER    

prtExVcPbxCnfgTable 1.3.6.1.4.1.164.3.2.3.2.15.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExVcPbxCnfgEntry

prtExVcPbxCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.15.1.1
An entry in table.
OBJECT-TYPE    
  PrtExVcPbxCnfgEntry  

prtExVcPbxCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.1.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtExVcPbxSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.1.1.2
This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.1.1.3
A unique identifier of the port, within the card.
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExVcPbxConnect 1.3.6.1.4.1.164.3.2.3.2.15.1.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExVcPbxGroup 1.3.6.1.4.1.164.3.2.3.2.15.1.1.5
The group object links together several VC-PBX cards, concerning compression of the same input T1/E1 link time-slots. When ports of different slots have the same group, they are linked. When ports have a different group, they are not linked. For VC-PBX/T1 and E1 cards, this object is - their own IO Slot. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVcPbxTransparent 1.3.6.1.4.1.164.3.2.3.2.15.1.1.6
This object indicates whether the Transparent transfer of Time-Slots is required or not. Time-Slots transferred by Transparent, will not be compressed. no - applicable only for VC-PBX/T1 and VC-PBX/E1 cards yes - applicable only for VC-PBX/T1 and VC-PBX/E1 cards notApplicable - only for VC-PBX cards.
OBJECT-TYPE    
  INTEGER no(2), yes(3), notApplicable(255)  

prtExVcPbxTransSignalTs 1.3.6.1.4.1.164.3.2.3.2.15.1.1.7
This object specifies the ML Time-Slot dedicated to the signaling of the PABX Transparent TSs. None = 255. When prtExVcPbxTransparent=no this object's value=None (255) When prtExVcPbxTransparent=notApplicable, this object's value=None (255). When prtExVcPbxTransparent=yes: - for VC-PBX/T1 ports, this object's valid values are 1..16 or None (255). - for VC-PBX/E1 ports, this object's value will be 16 or None (255).
OBJECT-TYPE    
  Integer32  

prtExVcPbxFrame 1.3.6.1.4.1.164.3.2.3.2.15.1.1.8
This object is the frame parameter for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 values for the VC-PBX/T1 card. E1 values for the VC-PBX/E1 card. notApplicable - for the VC-PBX card. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7)
OBJECT-TYPE    
  INTEGER esfT1(2), sfT1(3), g732nE1(4), g732nE1CRC(5), g732sE1(6), g732sE1CRC(7), notApplicable(255)  

prtExVcPbxRestoreTime 1.3.6.1.4.1.164.3.2.3.2.15.1.1.9
The time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface. ccittE1 - is applicable only for VC-PBX/E1 card notApplicable - is applicable for VC-PBX card
OBJECT-TYPE    
  INTEGER restoreT1secFast(2), restoreT10sec62411(3), ccittE1(4), notApplicable(255)  

prtExVcPbxLineCode 1.3.6.1.4.1.164.3.2.3.2.15.1.1.10
This object is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for VC-PBX/T1 E1 line code parameters for VC-PBX/E1 notApplicable - for VC-PBX This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
OBJECT-TYPE    
  INTEGER b7zsT1(1), b8zsT1(2), transT1(3), hdb3E1(4), notApplicable(255)  

prtExVcPbxLineLength 1.3.6.1.4.1.164.3.2.3.2.15.1.1.11
This object is the line length parameter. It is applicable only for the VC-PBX/T1 card. notApplicable - for the VC-PBX and VC-PBX/E1 card. lenXXXpXXXft = len-XXX-XXXft.
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), notApplicable(255)  

prtExVcPbxLinkTo 1.3.6.1.4.1.164.3.2.3.2.15.1.1.12
This object indicates the slot of the ML card to which the VC-PBX/T1, VC-PBX/E1 card Transparent TSs are mapped. notApplicable - for VC-PBX card AND for VC-PBX/T1, VC-PBX/E1 cards, when prtExVcPbxTransparent=no . In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVcPbxSignalOper 1.3.6.1.4.1.164.3.2.3.2.15.1.1.13
This object indicates the Signaling Operation of the VC-PBX/T1, VC-PBX/E1 external port. notApplicable - for VC-PBX card normal - all 4 signaling bits are transferred. bEqA - copy the A bit into the B bit. Applicable only for VC-PBX/T1.
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), bEqA(3), inverseA(4)  

prtExVcPbxIdleCode 1.3.6.1.4.1.164.3.2.3.2.15.1.1.14
Determines the code for transmission in empty time slots. notApplicable - for VC-PBX card .
OBJECT-TYPE    
  INTEGER notApplicable(1), hff(2), he4(3), hd5(4), h9e(5), h98(6), h7f(7), h7e(8), h54(9), h1a(10)  

prtIn1p6VcPbxCnfgTable 1.3.6.1.4.1.164.3.2.3.2.15.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIn1p6VcPbxCnfgEntry

prtIn1p6VcPbxCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.15.2.1
An entry in table.
OBJECT-TYPE    
  PrtIn1p6VcPbxCnfgEntry  

prtIn1p6VcPbxCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.2.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtIn1p6VcPbxSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.2.1.2
This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtIn1p6VcPbxPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.2.1.3
A unique identifier of the port, within the card.
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106)  

prtIn1p6VcPbxConnect 1.3.6.1.4.1.164.3.2.3.2.15.2.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtIn1p6VcPbxRate 1.3.6.1.4.1.164.3.2.3.2.15.2.1.5
This object indicates the port Rate. For Normal mode (prtIn7p8VcPbxMode=normal), only part of the values are valid (constant rate). For Server mode (prtIn7p8VcPbxMode=server), all values are applicable (user can select the desired compression rate).
OBJECT-TYPE    
  INTEGER r4800bps(1), r6400bps(2), r7200bps(3), r8000bps(4), r9600bps(5), r12800bps(6)  

prtIn1p6VcPbxEchoCanceler 1.3.6.1.4.1.164.3.2.3.2.15.2.1.6
Echo canceler activation.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtIn1p6VcPbxPabxTs 1.3.6.1.4.1.164.3.2.3.2.15.2.1.7
This object defines the PABX Time-Slot assigned to this internal port. For a T1 link, the valid values are: 1 .. 24. For an E1 link, the valid values are: 1 .. 31. This object is NOT applicable when prtIn1p6VcPbxConnect=no. This object is applicable for all cards of VC-PBX family. Default=the internal port index (1..6).
OBJECT-TYPE    
  Integer32 1..31  

prtIn7p8VcPbxCnfgTable 1.3.6.1.4.1.164.3.2.3.2.15.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIn7p8VcPbxCnfgEntry

prtIn7p8VcPbxCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.15.3.1
An entry in table.
OBJECT-TYPE    
  PrtIn7p8VcPbxCnfgEntry  

prtIn7p8VcPbxCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.3.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
OBJECT-TYPE    
  Integer32 1..255  

prtIn7p8VcPbxSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.3.1.2
This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtIn7p8VcPbxPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.3.1.3
A unique identifier of the port, within the card.
OBJECT-TYPE    
  INTEGER inPrt7(107), inPrt8(108)  

prtIn7p8VcPbxConnect 1.3.6.1.4.1.164.3.2.3.2.15.3.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtIn7p8VcPbxMode 1.3.6.1.4.1.164.3.2.3.2.15.3.1.5
This object indicates the working mode of the port: - normal - the compressed voice will be sent to an MTML card inside the Mux. - server - the compressed voice will be sent to the Digital Voice connector, as a service to an outside user.
OBJECT-TYPE    
  INTEGER normal(1), server(2)  

prtIn7p8VcPbxRate 1.3.6.1.4.1.164.3.2.3.2.15.3.1.6
This object indicates the port Main Rate. For Server mode (prtIn7p8VcPbxMode=server), the value will be notApplicable.
OBJECT-TYPE    
  INTEGER r32Kbps(1), r16Kbps(2), notApplicable(255)  

prtIn7p8VcPbxSignalMode 1.3.6.1.4.1.164.3.2.3.2.15.3.1.7
This object indicates the Signal Mode. For Server mode (prtIn7p8VcPbxMode=server), the only valid values are: - none - aBit
OBJECT-TYPE    
  INTEGER none(1), aBit(2), abcBit(3), abcdBit(4)  

prtIn7p8VcPbxOos 1.3.6.1.4.1.164.3.2.3.2.15.3.1.8
Out of service Signaling mode.
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2)  

prtIn7p8VcPbxLinkTo 1.3.6.1.4.1.164.3.2.3.2.15.3.1.9
This object indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For Server mode (prtIn7p8VcPbxMode=server), this object is not applicable. Both ports, 7 and 8 should be linked to the same Slot. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVcPbxTsTable 1.3.6.1.4.1.164.3.2.3.2.15.4
The write operation into the table objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExVcPbxTsEntry

prtExVcPbxTsEntry 1.3.6.1.4.1.164.3.2.3.2.15.4.1
An entry in table.
OBJECT-TYPE    
  PrtExVcPbxTsEntry  

prtExVcPbxTsCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtExVcPbxTsSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxTsPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.3
This attribute indicates a unique port number. VCPBX/E1 and VCPBX/T1 cards have only one external interface.
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExVcPbxTsIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.4
This attribute indicates a unique PABX time slot position. The valid time slots are 1..24 for VC-PBX/T1 and 1..31 for VC-PBX/E1.
OBJECT-TYPE    
  Integer32  

prtExVcPbxTsMode 1.3.6.1.4.1.164.3.2.3.2.15.4.1.5
This attribute indicates the usage, process and way of the specific PABX TS towards its destination: unused - the TS is not used (no processing, no destination). compressed - the TS is used, sent for compression to an internal port 1..6 of either the same card or a VC-PBX card of the same group. transparent - the TS is used, no processing, it is sent directly to the ML card the VC-PBX/T1,(E1) is linked to.
OBJECT-TYPE    
  INTEGER unused(1), compressed(2), transparent(3)  

prtExVcPbxTsIConSlot 1.3.6.1.4.1.164.3.2.3.2.15.4.1.6
The object's io1..io12 values are applicable only when prtExVcPbxTsMode=compressed. Otherwise, its value should be noConnect. This object indicates whether the specified compressed time slot is connected/routed internally in the Agent and to which card it is connected. The valid selectable slots are either the current one, (prtExVcPbxTsSltIdx), or a slot containing a VC-PBX card. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxTsIConPrt 1.3.6.1.4.1.164.3.2.3.2.15.4.1.7
This attribute indicates the internal VC-PBX port to which this PABX TS is connected for compression. noConnect - when prtExVcPbxTsIConSlot=noConnect.
OBJECT-TYPE    
  INTEGER noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106)  

prtIsdnCnfg 1.3.6.1.4.1.164.3.2.3.2.16
OBJECT IDENTIFIER    

prtIsdnCnfgTable 1.3.6.1.4.1.164.3.2.3.2.16.1
The write operation into the table objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIsdnCnfgEntry

prtIsdnCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.16.1.1
An entry in table.
OBJECT-TYPE    
  PrtIsdnCnfgEntry  

prtIsdnCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.16.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtIsdnSltIdx 1.3.6.1.4.1.164.3.2.3.2.16.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA(103), kmxMlB(104), notApplicable(255)  

prtIsdnPrtIdx 1.3.6.1.4.1.164.3.2.3.2.16.1.1.3
This attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch
OBJECT-TYPE    
  Integer32  

prtIsdnConnect 1.3.6.1.4.1.164.3.2.3.2.16.1.1.4
This attribute indicates if the port is connected.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtIsdnSignalingProtocol 1.3.6.1.4.1.164.3.2.3.2.16.1.1.5
This attribute fixes which signaling protocol is used at this port (D-Channel). It is equivalent to isdnSignalingProtocol in the isdn MIB.
OBJECT-TYPE    
  INTEGER other(1), etsi(3), ess5(6), dms100(7), ni1(9), ni2(10), ins64(17), ins1500(18), qsig(21), notApplicable(255)  

prtIsdnBasicRateLineTopology 1.3.6.1.4.1.164.3.2.3.2.16.1.1.6
This attribute is relevant for ISDN BRI only. It is equivalent to isdnBasicRateLineTopology in the isdn MIB.
OBJECT-TYPE    
  INTEGER pointToPoint(1), pointToMultipoint(2), notApplicable(255)  

prtIsdnMode 1.3.6.1.4.1.164.3.2.3.2.16.1.1.7
This attribute allows the user to configure the port as leased(2) in case of connection to a TDM network.
OBJECT-TYPE    
  INTEGER dialup(1), leased(2), syncLeased(3), notApplicable(255)  

prtIsdnFilter 1.3.6.1.4.1.164.3.2.3.2.16.1.1.8
This attribute allows the user to configure the port: answerAll(2): accept all incoming calls, rejectAll(3): reject all incoming calls, selective(4): accept or reject according directory table. callBack (5): In this mode the ISDN Ch will reject incoming calls and will initiate call back to the rejected phone number.
OBJECT-TYPE    
  INTEGER notApplicable(1), answerAll(2), rejectAll(3), selective(4), callBack(5)  

prtIsdnSimultaneousCall 1.3.6.1.4.1.164.3.2.3.2.16.1.1.9
In case of simultaneous call (local,remote and remote,local): accept(2): accept the incoming call, reject(3): reject the incoming call.
OBJECT-TYPE    
  INTEGER notApplicable(1), accept(2), reject(3)  

prtIsdnNumOfAbstractTerm 1.3.6.1.4.1.164.3.2.3.2.16.1.1.10
An object for KM2100/4 agents. 255=Not Applicable When ISDN Standard = ETSI or NTT (European) the value should be 255 (NotApplicable) else If ML speed is 64Kbps value should be 1. If ML speed is 128Kbps value can be either 1 or 2 (user selection).
OBJECT-TYPE    
  Integer32  

prtIsdnSwitchMode 1.3.6.1.4.1.164.3.2.3.2.16.1.1.11
For KM2100. auto - The call is initiated automatically by one of the IO cards connected to KML.10(ISDN card) having ISDN Switch Mode. manual - The call is initiated by the user manually, for KML.10 having ISDN Switch Mode (via mdlSCmd). connect- The call is initiated 'immediately', for KML.10 having ISDN Switch Mode. 'immediately'- means: immediately after power-up (when product performed Reset) OR, since this value appears in the active configuration. In this case, the call can be disconnected only by power-off of the product or by changing this object to another value (or actual Remove of the KML.10 relevant card). notApplicable - For other card types.
OBJECT-TYPE    
  INTEGER notApplicable(1), auto(2), manual(3), connect(4)  

prtIsdnAbSide 1.3.6.1.4.1.164.3.2.3.2.16.1.1.12
This parameter indicates the QSIG side in layer 3. This definition is from the QSIG Standard.
OBJECT-TYPE    
  INTEGER notApplicable(1), aSide(2), bSide(3)  

prtIsdnQsigRole 1.3.6.1.4.1.164.3.2.3.2.16.1.1.13
This parameter indicates the QSIG side in layer 1 & 2.
OBJECT-TYPE    
  INTEGER notApplicable(1), slave(2), master(3)  

prtIsdnInterface 1.3.6.1.4.1.164.3.2.3.2.16.1.1.14
It indicates the interface type: lt = line termination nt = network termination te = terminal equipment.
OBJECT-TYPE    
  INTEGER lt(1), nt(2), te(3), notApplicable(255)  

prtIsdnCallMode 1.3.6.1.4.1.164.3.2.3.2.16.1.1.15
This object indicates the acceptance of incoming calls. Initiate - Callout Listen - Callin.
OBJECT-TYPE    
  INTEGER notApplicable(1), initiate(2), listen(3)  

prtIsdnCallBackTimeout 1.3.6.1.4.1.164.3.2.3.2.16.1.1.16
This object is applicable only if 'prtIsdnFilter' is 'CallBack' and determines how long to wait from receiving the incoming call until initiating the call back call. The vaules range should be '1..20 sec' and the default 10 sec.
OBJECT-TYPE    
  INTEGER  

prtIsdnEndpointTable 1.3.6.1.4.1.164.3.2.3.2.16.2
The write operation into the table objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIsdnEndpointEntry

prtIsdnEndpointEntry 1.3.6.1.4.1.164.3.2.3.2.16.2.1
An entry in table.
OBJECT-TYPE    
  PrtIsdnEndpointEntry  

prtIsdnEndpointCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtIsdnEndpointSltIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.2
This attribute indicates a unique slot position where the card is inserted. In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA(103), kmxMlB(104), notApplicable(255)  

prtIsdnEndpointPrtIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.3
This attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch
OBJECT-TYPE    
  Integer32  

prtIsdnEndpointIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.4
Since more than one endpoint may be defined per isdn entity, this field is a simple index. It corresponds to isdnEndpointIdx in the isdn MIB.
OBJECT-TYPE    
  INTEGER atei1(1), atei2(2)  

prtIsdnEndpointTeiType 1.3.6.1.4.1.164.3.2.3.2.16.2.1.5
The type of TEI (Terminal Endpoint Identifier) used for this Terminal Endpoint. In case of dynamic(1), the TEI value is selected by the switch. In case of static(2), a valid TEI value has to be entered in the isdnEndpointTeiValue object. interface type as well as the Terminal Endpoint type. static(2). On Basic Rate interfaces the default value is dynamic(1) for isdn(63) Terminal Endpoints. It corresponds to isdnEndpointTeiType in the isdn MIB.
OBJECT-TYPE    
  INTEGER dynamic(1), static(2), notApplicable(255)  

prtIsdnEndpointTeiValue 1.3.6.1.4.1.164.3.2.3.2.16.2.1.6
When the TEI Type is static, the value of the TEI should be between 0 and 63. Else, it is not selectable by user. 255 = notApplicable. It corresponds to isdnEndpointTeiValue in the isdn MIB
OBJECT-TYPE    
  Integer32  

prtIsdnEndpointSpid 1.3.6.1.4.1.164.3.2.3.2.16.2.1.7
The Service profile IDentifier (SPID) information for this Terminal Endpoint. It is is composed of 9-20 numeric characters. It corresponds to isdnEndpointSpid in the isdn MIB.
OBJECT-TYPE    
  DisplayString  

prtIsdnEndpointBearerCh 1.3.6.1.4.1.164.3.2.3.2.16.2.1.8
This is the selected dialing channel. anyChannel - the system selects the dialing channel.
OBJECT-TYPE    
  INTEGER notApplicable(1), anyChannel(2), channelB1(3), channelB2(4)  

prtIsdnEndpointRowStatus 1.3.6.1.4.1.164.3.2.3.2.16.2.1.9
This field indicates whether to consider this endpoint or not. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

prtIsdnDirectoryTable 1.3.6.1.4.1.164.3.2.3.2.16.3
The write operation into the table objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIsdnDirectoryEntry

prtIsdnDirectoryEntry 1.3.6.1.4.1.164.3.2.3.2.16.3.1
An entry in table.
OBJECT-TYPE    
  PrtIsdnDirectoryEntry  

prtIsdnDirectoryCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.16.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtIsdnDirectorySltIdx 1.3.6.1.4.1.164.3.2.3.2.16.3.1.2
This attribute indicates a unique slot position where the card is inserted. For MX300/30 ports: io1(5) = isdn1(5) and io2(6) = isdn2(6). In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA(103), kmxMlB(104), notApplicable(255)  

prtIsdnDirectoryPrtIdx 1.3.6.1.4.1.164.3.2.3.2.16.3.1.3
For MAXcess this is the internal port number: 101, 102,.... For KM-2100 the port index is calculated as follows: 100*Slot+Ch
OBJECT-TYPE    
  Integer32  

prtIsdnDirectoryLocalAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.4
This is the local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
OBJECT-TYPE    
  DisplayString SIZE(17..20)  

prtIsdnDirectoryLocalSubAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.5
This is the local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
OBJECT-TYPE    
  DisplayString SIZE(4..6)  

prtIsdnDirectoryRemoteAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.6
This is the remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
OBJECT-TYPE    
  DisplayString SIZE(17..20)  

prtIsdnDirectoryRemoteSubAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.7
This is the remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
OBJECT-TYPE    
  DisplayString SIZE(4..6)  

prtIsdnDirectoryPrtNu 1.3.6.1.4.1.164.3.2.3.2.16.3.1.8
This is the external port number connected to this entry.
OBJECT-TYPE    
  Integer32  

prtIsdnDirectoryTeiId 1.3.6.1.4.1.164.3.2.3.2.16.3.1.9
This is the abstract terminal id if relevant, connected to this entry.
OBJECT-TYPE    
  Integer32  

prtIsdnDirectoryRowStatus 1.3.6.1.4.1.164.3.2.3.2.16.3.1.10
This is the status for the row. It allows to know whether to consider this row or not. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

prtIsdnDirectoryLocalAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.11
This is the second local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
OBJECT-TYPE    
  DisplayString SIZE(17..20)  

prtIsdnDirectoryLocalSubAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.12
This is the second local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
OBJECT-TYPE    
  DisplayString SIZE(4..6)  

prtIsdnDirectoryRemoteAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.13
This is the second remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank(20 characters)
OBJECT-TYPE    
  DisplayString SIZE(17..20)  

prtIsdnDirectoryRemoteSubAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.14
This is the second remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
OBJECT-TYPE    
  DisplayString SIZE(4..6)  

prtLogicalCnfg 1.3.6.1.4.1.164.3.2.3.2.17
OBJECT IDENTIFIER    

prtLogicalCnfgTable 1.3.6.1.4.1.164.3.2.3.2.17.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtLogicalCnfgEntry

prtLogicalCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.17.1.1
An entry in table.
OBJECT-TYPE    
  PrtLogicalCnfgEntry  

prtLogicalCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.17.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtLogicalSltIdx 1.3.6.1.4.1.164.3.2.3.2.17.1.1.2
Slot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtLogicalPrtIdx 1.3.6.1.4.1.164.3.2.3.2.17.1.1.3
This attribute indicates a unique port number. This port number should be an internal port number: inPrt1(101)->inPrt50(150), linkSel1(200)->linkSel50(250), encaps1(300)-> encaps50(350), huntGr1(101) -> huntGr10(110).
OBJECT-TYPE    
  Integer32  

prtLogicalConnect 1.3.6.1.4.1.164.3.2.3.2.17.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtLogicalFunction 1.3.6.1.4.1.164.3.2.3.2.17.1.1.5
This parameter defines the function of the relevant channel.
OBJECT-TYPE    
  INTEGER notApplicable(1), linkSelector(2), encapsulator(3), huntGroup(4)  

prtLogicalRowStatus 1.3.6.1.4.1.164.3.2.3.2.17.1.1.6
This parameter allows the NMS to create/delete logical ports. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

linkSelectorCnfgTable 1.3.6.1.4.1.164.3.2.3.2.17.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    LinkSelectorCnfgEntry

linkSelectorCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.17.2.1
An entry in table.
OBJECT-TYPE    
  LinkSelectorCnfgEntry  

linkSelectorCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.17.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

linkSelectorSltIdx 1.3.6.1.4.1.164.3.2.3.2.17.2.1.2
Slot Index
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

linkSelectorPrtIdx 1.3.6.1.4.1.164.3.2.3.2.17.2.1.3
This attribute indicates a unique port number. This port number should be internal port number: higher or equal to linkSeL1(201).
OBJECT-TYPE    
  Integer32  

linkSelectorMaxIdleTime 1.3.6.1.4.1.164.3.2.3.2.17.2.1.4
Move to higher prioritized connected link after this period of seconds of silence on the current link. 0=move immediately to higher prioritized connected link. UNIT is seconds.
OBJECT-TYPE    
  Integer32 0..255  

linkSelectorMode 1.3.6.1.4.1.164.3.2.3.2.17.2.1.5
If the link selector is in mode: backup(2)=then the link with the lower priority will be used in case of failure of the higher priority link, bod(3)=bandwidth on demand or dynamic bandwidth allocation means that links with lower priority will be used whenever additional bandwidth is required.
OBJECT-TYPE    
  INTEGER notApplicable(1), backup(2), bod(3)  

linkSelectorRevert 1.3.6.1.4.1.164.3.2.3.2.17.2.1.6
If the link selector is in mode backup: auto(2)=return automatically to Main link when it is OK. manual(3)=stays connected to backup link.
OBJECT-TYPE    
  INTEGER notApplicable(1), auto(2), manual(3)  

linkSelectorMinBUSession 1.3.6.1.4.1.164.3.2.3.2.17.2.1.7
Minimum duration of a backup session before returning to Main Link. Relevant in Backup Mode and when Revert is auto(2). Value 255 is for NEVER which means never return to Main Link. UNIT is minutes.
OBJECT-TYPE    
  Integer32 1..255  

linkSelectorPLinkTable 1.3.6.1.4.1.164.3.2.3.2.17.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    LinkSelectorPLinkEntry

linkSelectorPLinkEntry 1.3.6.1.4.1.164.3.2.3.2.17.3.1
An entry in table.
OBJECT-TYPE    
  LinkSelectorPLinkEntry  

pLinkCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

pLinkSltIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.2
Slot Index
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

pLinkPrtIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.3
This attribute indicates a unique port number. This port number should be the link selector number.
OBJECT-TYPE    
  Integer32 200..250  

pLinkIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.4
This index is the row number.
OBJECT-TYPE    
  Integer32 1..8  

pLinkSlotNu 1.3.6.1.4.1.164.3.2.3.2.17.3.1.5
The slot of the prioritized link. For ISDN BRI ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

pLinkPortNu 1.3.6.1.4.1.164.3.2.3.2.17.3.1.6
The port of the prioritized link. Value 100 is for noConnect.
OBJECT-TYPE    
  Integer32  

pLinkPrioNu 1.3.6.1.4.1.164.3.2.3.2.17.3.1.7
The priority of the prioritized link. MIN=1...., MAX=8.
OBJECT-TYPE    
  Integer32 1..8  

pLinkVRate 1.3.6.1.4.1.164.3.2.3.2.17.3.1.8
The rate to use with this link.
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17), r9x64eq576Kbps(18), r10x56eq560Kbps(19), r10x64eq640Kbps(20), r11x56eq616Kbps(21), r11x64eq704Kbps(22), r12x56eq672Kbps(23), r12x64eq768Kbps(24), r13x56eq728Kbps(25), r13x64eq832Kbps(26), r14x56eq784Kbps(27), r14x64eq896Kbps(28), r15x56eq840Kbps(29), r15x64eq960Kbps(30), r16x56eq896Kbps(31), r16x64eq1024Kbps(32), r17x56eq952Kbps(33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), noRate(100)  

prtFrPlusCnfg 1.3.6.1.4.1.164.3.2.3.2.18
OBJECT IDENTIFIER    

prtFrPlusCnfgTable 1.3.6.1.4.1.164.3.2.3.2.18.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtFrPlusCnfgEntry

prtFrPlusCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.18.1.1
An entry in table.
OBJECT-TYPE    
  PrtFrPlusCnfgEntry  

prtFrPlusCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.18.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtFrPlusSltIdx 1.3.6.1.4.1.164.3.2.3.2.18.1.1.2
Slot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtFrPlusPrtIdx 1.3.6.1.4.1.164.3.2.3.2.18.1.1.3
This attribute indicates a unique port number. This port number should be: - for ISDN cards: inPrt1(101)->inPrt50(150) - for MHS1 card : exPrt1(1) - for MHS3, MLS3 cards: exPrt1(1)->exPrt3(3) - for MLS6 cards: exPrt1(1)->exPrt6(6).
OBJECT-TYPE    
  Integer32  

prtFrPlusNotSegmentedPriorities 1.3.6.1.4.1.164.3.2.3.2.18.1.1.4
This parameter is relevant only for FR+ protocol and asks the MXcess NOT to segment data with specified priorities: from LSB: bit 1 is for priority 1, bit 2 is for priority 2, .... till bit 7 for priority 7. - a priority selected to be segmented : its bit will be '0' - a priority not to be segmented : its bit will be '1' Default is 00000000; i.e, segment all priorities.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

prtMl4Cnfg 1.3.6.1.4.1.164.3.2.3.2.19
OBJECT IDENTIFIER    

prtMl4CnfgTable 1.3.6.1.4.1.164.3.2.3.2.19.1
This is an extension table for MTML-4 card parameters.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtMl4CnfgEntry

prtMl4CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.19.1.1
An entry in table.
OBJECT-TYPE    
  PrtMl4CnfgEntry  

prtMl4CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.19.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtMl4SltIdx 1.3.6.1.4.1.164.3.2.3.2.19.1.1.2
This attribute indicates a unique slot position where the module is inserted.
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtMl4PrtIdx 1.3.6.1.4.1.164.3.2.3.2.19.1.1.3
This attribute indicates a unique port number.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104)  

prtMl4SigProfile 1.3.6.1.4.1.164.3.2.3.2.19.1.1.4
This object indicates the Signaling Profile of the port. none - when the Frame is G732N (no MF). p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 p5 = profile 5
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), p1(3), p2(4), p3(5), p4(6), p5(7)  

prtMl4CGA 1.3.6.1.4.1.164.3.2.3.2.19.1.1.5
This object selects the method used to signal the CGA state to the other end, through the main link. 'none' - non-transparent mode. When one of the links (main) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos' will be transmitted to the other end. 'trans' - when one of the links (main) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos' will be transmitted to the other end.
OBJECT-TYPE    
  INTEGER none(1), trans(2), full(3)  

prtMl4Oos 1.3.6.1.4.1.164.3.2.3.2.19.1.1.6
'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0
OBJECT-TYPE    
  INTEGER notSupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtMl4VoiceOos 1.3.6.1.4.1.164.3.2.3.2.19.1.1.7
Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
OBJECT-TYPE    
  OCTET STRING SIZE(0..4)  

prtMl4DataOos 1.3.6.1.4.1.164.3.2.3.2.19.1.1.8
Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
OBJECT-TYPE    
  OCTET STRING SIZE(0..4)  

prtMl4Service 1.3.6.1.4.1.164.3.2.3.2.19.1.1.9
Link Service. leasedLine - usual TDM interface. v51 - V5.1 interface.
OBJECT-TYPE    
  INTEGER notApplicable(1), leasedLine(2), v51(3)  

prtMl4IpAddress 1.3.6.1.4.1.164.3.2.3.2.19.1.1.10
IP Address of the port.
OBJECT-TYPE    
  IpAddress  

prtMl4IpMask 1.3.6.1.4.1.164.3.2.3.2.19.1.1.11
IP subnet mask of the port.
OBJECT-TYPE    
  IpAddress  

prtMl4SignalingMode 1.3.6.1.4.1.164.3.2.3.2.19.1.1.12
Refers to the signaling mode of the Framer module. cas(2) means Channel Associated Signaling. Used for E1 Links. ccs(3) is the Common Channel Signaling (the signaling is not within the channels time slot - a TS for signaling is used). robbedBit(4) is a method implementing 7 bits for the voice and 1 bit dedicated for signaling. Used for T1 Links.
OBJECT-TYPE    
  INTEGER notApplicable(1), cas(2), ccs(3), robbedBit(4)  

prtMl4EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.19.1.1.13
Echo canceler activation.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtMl4OosErrorSource 1.3.6.1.4.1.164.3.2.3.2.19.1.1.14
OOS (Out-of-Service) Error Source. This object is applicable for T1 ports only.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), framing(3), bpv(4)  

prtMl4OosEntryThreshold 1.3.6.1.4.1.164.3.2.3.2.19.1.1.15
This object defines the number of Errors per Second that determine the minimum unacceptable noise level. This value will be the Entry Threshold to the OOS (Out-of-Service) state. This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable.
OBJECT-TYPE    
  Integer32 0..999  

prtMl4OosExitThreshold 1.3.6.1.4.1.164.3.2.3.2.19.1.1.16
This object defines the number of consecutive Error-Free-Seconds before going from OOS state to Normal state. This value will be the Exit Threshold from the OOS (Out-of-Service) state. Units=seconds This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable.
OBJECT-TYPE    
  Integer32 0..99  

prtAcmCnfg 1.3.6.1.4.1.164.3.2.3.2.20
OBJECT IDENTIFIER    

prtAcmCnfgTable 1.3.6.1.4.1.164.3.2.3.2.20.1
This is a table for ACM port parameters.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAcmCnfgEntry

prtAcmCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.20.1.1
An entry in table.
OBJECT-TYPE    
  PrtAcmCnfgEntry  

prtAcmCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.20.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtAcmSltIdx 1.3.6.1.4.1.164.3.2.3.2.20.1.1.2
This attribute indicates a unique slot position where the module is inserted.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtAcmPrtIdx 1.3.6.1.4.1.164.3.2.3.2.20.1.1.3
This attribute indicates a unique port number.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtAcmConnect 1.3.6.1.4.1.164.3.2.3.2.20.1.1.4
This attribute indicates whether the port should be connected or not. Only a connected port can perform activity.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtAcmActiveState 1.3.6.1.4.1.164.3.2.3.2.20.1.1.5
This attribute indicates the Electric Active State of the port.
OBJECT-TYPE    
  INTEGER low(2), high(3)  

prtAcmAlrString 1.3.6.1.4.1.164.3.2.3.2.20.1.1.6
Alarm string selected by user for the Inbound ports. This object is applicable only for the Inbound Ports: ext-5..ext-12. For the Outbound Ports (ext-1..ext-4), the size of this string will be 0.
OBJECT-TYPE    
  DisplayString SIZE(0..35)  

prtE2Cnfg 1.3.6.1.4.1.164.3.2.3.2.21
OBJECT IDENTIFIER    

prtE2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.21.1
This is a table for E2 port parameters.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtE2CnfgEntry

prtE2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.21.1.1
An entry in table.
OBJECT-TYPE    
  PrtE2CnfgEntry  

prtE2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.21.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtE2SltIdx 1.3.6.1.4.1.164.3.2.3.2.21.1.1.2
This attribute indicates a unique slot position where the module is inserted.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtE2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.21.1.1.3
This attribute indicates a unique port number.
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2)  

prtE2Connect 1.3.6.1.4.1.164.3.2.3.2.21.1.1.4
This attribute indicates whether the port should be connected or not. Only a connected port can perform activity.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtE2MngOnNationalBit 1.3.6.1.4.1.164.3.2.3.2.21.1.1.5
This attribute indicates whether National Bit will be used for Management or not.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

dacsMux 1.3.6.1.4.1.164.3.3
OBJECT IDENTIFIER    

dacsMuxEvents 1.3.6.1.4.1.164.3.3.0
The events for DACS MUX.
OBJECT-IDENTITY    

sanityCheckTrap 1.3.6.1.4.1.164.3.3.0.1
This trap is sent after a data base download attempt. It returns the sanity result status and the configuration no.checked.
NOTIFICATION-TYPE    
  sysSSanityCheckStatus  
  sysDbaseDownloadCnfgIdxCmd  

dacsMuxAlarmsTrap 1.3.6.1.4.1.164.3.3.0.2
This trap is sent when an alarm occurs.
NOTIFICATION-TYPE    

mdlConnectTrap 1.3.6.1.4.1.164.3.3.0.3
This trap is sent when a card is removed.
NOTIFICATION-TYPE    
  mdlSCardType  
  mdlSActivity  

sysAlrStatusTrap 1.3.6.1.4.1.164.3.3.0.4
This trap is sent upon any change in the value of any of the variables.
NOTIFICATION-TYPE    
  sysSAlrStatusAll  
  sysSAlrStatus  

sysStatusChangedTrap 1.3.6.1.4.1.164.3.3.0.5
This trap is sent when Leds status is changed.
NOTIFICATION-TYPE    
  agnLed  

cnfgUpdateTrap 1.3.6.1.4.1.164.3.3.0.6
This trap is sent upon change of the active Configuration DB.
NOTIFICATION-TYPE    

systemDacsMux 1.3.6.1.4.1.164.3.3.1
OBJECT IDENTIFIER    

sysSa 1.3.6.1.4.1.164.3.3.1.1
OBJECT IDENTIFIER    

sysSaSwchStatus 1.3.6.1.4.1.164.3.3.1.1.1
This object indicates the status of the switches on the SA unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits. For SMODs products see modem's specification. For DXC product see the following: There are 4 switches: bit 0 SP-PAR (LSB) '1' - Default parameters bit 1 PSWRD '1' - Password=default '0' - Password=user selected bit 2 DB-INIT '1' - DB initiated with default '0' - DB initiated with NVRAM contents bit 3 PC-SP (MSB) '1' - Management by terminal only '0' - Management by NMS Example: If SP-PAR and PSWRD bits are set ('1'), the value will be 3 (2**1 + 2**0). When the status of the switches is unknown, the value of this object will be 255.
OBJECT-TYPE    
  Integer32  

sysSaSwRevision 1.3.6.1.4.1.164.3.3.1.1.2
This object indicates the Software revision of the system.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

sysSaHwVersion 1.3.6.1.4.1.164.3.3.1.1.3
This object indicates the Hardware version of the system.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

sysSaPorts 1.3.6.1.4.1.164.3.3.1.1.4
This object indicates the ports that are present in the system. Each possible port is represented by a bit. The value of this object is a sum of 2**n, n=number of bits. '1' - means that the port exists '0' - means that the port does not exist For detailed bit assignment, see product's spec. Bit 0 = LSB When this object is not relevant, the value will be 0. In some cases, this object may represent ports configuration of the system AND its far-end unit.
OBJECT-TYPE    
  Integer32  

sysSaReadSwch 1.3.6.1.4.1.164.3.3.1.1.5
This object indicates wether the configuration will be read from the DIP switches on the SA (stand alone) unit. Each switch is represented by a bit. If the bit is 1: the configuration will be read from the HW switch position. If the bit is 0: the configuration will be read from the SW user configuration. The DIP switches are different in each of the RAD devices. In the Tiny Router (starting from the LSB) the following switches exist: Bit 0: WAN Loop Bit 1: LAN Full Duplex (When LAN AUI connector, it is SQE) Bit 2: PPP (When WAN 4 Wire connector, it is LONG) Bit 3: IP Learn
OBJECT-TYPE    
  Integer32  

sysHub 1.3.6.1.4.1.164.3.3.1.2
OBJECT IDENTIFIER    

sysChas 1.3.6.1.4.1.164.3.3.1.2.1
OBJECT IDENTIFIER    

chassTotalNoOfSlt 1.3.6.1.4.1.164.3.3.1.2.1.1
This object indicates the number of physical slots in the Hub chassis.
OBJECT-TYPE    
  Integer32  

chassTotalNoOfIoSlt 1.3.6.1.4.1.164.3.3.1.2.1.2
This object indicates the total number of physical IO slots in the chassis, (not all slots must be occupied and active).
OBJECT-TYPE    
  Integer32  

chassTotalNoOfPsSlt 1.3.6.1.4.1.164.3.3.1.2.1.3
This object indicates the number of physical Power Supply slots in the chassis.
OBJECT-TYPE    
  Integer32  

chassTotalNoOfClSlt 1.3.6.1.4.1.164.3.3.1.2.1.4
This object indicates the number of physical Common Logic slots in the chassis.
OBJECT-TYPE    
  Integer32  

chassTotalNoOfMlSlt 1.3.6.1.4.1.164.3.3.1.2.1.5
This object indicates the number of physical Main Link slots in the chassis (Kmux).
OBJECT-TYPE    
  Integer32  

sysDcl 1.3.6.1.4.1.164.3.3.1.2.2
OBJECT IDENTIFIER    

sysDclTable 1.3.6.1.4.1.164.3.3.1.2.2.1
All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    SysDclEntry

sysDclEntry 1.3.6.1.4.1.164.3.3.1.2.2.1.1
An entry in table.
OBJECT-TYPE    
  SysDclEntry  

sysDclCnfgIdx 1.3.6.1.4.1.164.3.3.1.2.2.1.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg. This object is identical for all the configurations (1..255). Only the TmpCnf(255) might have a different value.
OBJECT-TYPE    
  Integer32 1..255  

sysDclRedundancy 1.3.6.1.4.1.164.3.3.1.2.2.1.1.2
DCL redundancy desired state.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysDclActiveCl 1.3.6.1.4.1.164.3.3.1.2.2.1.1.3
Active desired DCL. When 'auto' is selected, the system automatically selects the active DCL.
OBJECT-TYPE    
  INTEGER auto(1), dclA(2), dclB(3)  

sysDclFlipDelay 1.3.6.1.4.1.164.3.3.1.2.2.1.1.4
If one DCL flip occured and a second one should be performed, the time from the previous flip is checked. If the time is shorter than the delay specified here (in minutes), the system should delay the flip operation until time reaches the specified delay.
OBJECT-TYPE    
  INTEGER t1min(1), t2min(2), t3min(3), t4min(4)  

sysDclFlipUponStnClk 1.3.6.1.4.1.164.3.3.1.2.2.1.1.5
This object allows user to decide (yes/no) if Agent should Flip from one DCL card to another, when there is Station Clock Fail in the Online DCL card.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

sysDclOnline 1.3.6.1.4.1.164.3.3.1.2.2.2
The active Dcl card of the agent.
OBJECT-TYPE    
  INTEGER dclA(1), dclB(2)  

sysDclCopyDbTable 1.3.6.1.4.1.164.3.3.1.2.2.3
This table enables to copy a cofiguration from the Offline Dcl to the Online Dcl.
OBJECT-TYPE    
  SEQUENCE OF  
    SysDclCopyDbEntry

sysDclCopyDbEntry 1.3.6.1.4.1.164.3.3.1.2.2.3.1
An entry in table.
OBJECT-TYPE    
  SysDclCopyDbEntry  

sysDclCopyDbIdx 1.3.6.1.4.1.164.3.3.1.2.2.3.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed.
OBJECT-TYPE    
  Integer32 1..255  

sysDclCopyDbCmd 1.3.6.1.4.1.164.3.3.1.2.2.3.1.2
When this command is sent to the agent, on(3), the Database specified (Db Idx), will be copied from the Offline Dcl to the Online Dcl. Afterwards the value of this object will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysStatus 1.3.6.1.4.1.164.3.3.1.3
OBJECT IDENTIFIER    

sysSDateFormat 1.3.6.1.4.1.164.3.3.1.3.1
This object indicates the date and time format used for the sysSDateAndTimeCmd and for the alarm buffer report.
OBJECT-TYPE    
  INTEGER ddMMYYYY(1), mmDDYYYY(2), yyyyMMDD(4)  

sysSDateCmd 1.3.6.1.4.1.164.3.3.1.3.2
This object indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the sysSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent. * For KM-2100 V1 and FCD-T1/E1 - the string should contain '/' signs between day, month and year. Example: 12/08/1998. * For DXC and rest of the products - the string should contain '-' signs between day, month and year. Example: 12-08-1998. The day value will be in the range: 1..31. The month value will be in the range: 1..12. The year value will be in the range: 1996..2050 for products supporting the '-' format.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

sysSTimeCmd 1.3.6.1.4.1.164.3.3.1.3.3
This object indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent. The string should contain ':' signs between hour, minute and second. Example: 11:05:58.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

sysSActiveCnfg 1.3.6.1.4.1.164.3.3.1.3.4
This object specifies the configuration number, that is currently active and running.
OBJECT-TYPE    
  Integer32  

sysSEditCnfg 1.3.6.1.4.1.164.3.3.1.3.5
This object indicates the unique configuration number that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process.
OBJECT-TYPE    
  Integer32  

sysSEditBy 1.3.6.1.4.1.164.3.3.1.3.6
This entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after a load operation.
OBJECT-TYPE    
  INTEGER none(1), snmp(2), terCon1(3), terCon2(4), terInbandCon1(5), terInbandCon2(6), lcd(7)  

sysSClkSrc 1.3.6.1.4.1.164.3.3.1.3.7
This entry indicates the source of the system clock.
OBJECT-TYPE    
  INTEGER master(1), fallback(2), internal(3), ml(4)  

sysSAlrStatus 1.3.6.1.4.1.164.3.3.1.3.8
Indicates the current alarm state only for system level. This object will be : - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4), event(5), warning(6), critical(7)  

sysSAlrStatusAll 1.3.6.1.4.1.164.3.3.1.3.9
Indicates the current alarm state including all levels: system, card, port. - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4), event(5), warning(6), critical(7)  

sysSTestStatus 1.3.6.1.4.1.164.3.3.1.3.10
Indicates the current test status (for all levels: system, card, port). This attribute will be set to: - on(3): when there is at least one test in progress on the system/card/port otherwise the value will be off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSSanityCheckStatus 1.3.6.1.4.1.164.3.3.1.3.11
Upon completion of the Sanity Check process on the TmpCnfg this object will be set to: - fail(2): when there is at least one error (which is not just a warning) encountered otherwise, - warning(3): when there are only warnings otherwise, - ok(4). The value should be unknown(1), if the TmpCnfg was changed after the last Sanity check.
OBJECT-TYPE    
  INTEGER unknown(1), fail(2), warning(3), ok(4)  

sysSNoOfSanityCheckErr 1.3.6.1.4.1.164.3.3.1.3.12
This object indicates the number of errors/warnings discovered by the last Sanity Check process.
OBJECT-TYPE    
  Integer32  

sysSErrListTable 1.3.6.1.4.1.164.3.3.1.3.13
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    SysSErrListEntry

sysSErrListEntry 1.3.6.1.4.1.164.3.3.1.3.13.1
An entry in table.
OBJECT-TYPE    
  SysSErrListEntry  

sysSErrType 1.3.6.1.4.1.164.3.3.1.3.13.1.1
The errors are recorded in the agent, in two separate lists, according to their type: error or warning.
OBJECT-TYPE    
  INTEGER error(1), warning(2)  

sysSErrIdx 1.3.6.1.4.1.164.3.3.1.3.13.1.2
Unique index number to identify an entry in the error or warning list . The maximum value cannot exceed the value of 'sysSNoOfSanityCheckErr' (actually, the sum of the Errors list max. index and the Warning list max. index should equal the value of'sysSNoOfSanityCheckErr').
OBJECT-TYPE    
  Integer32  

sysSErrDescription 1.3.6.1.4.1.164.3.3.1.3.13.1.3
This object is a full text description of the sanity check error including error code, IO slot and port numbers related to the code .
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

sysSMaxNoOfCnfg 1.3.6.1.4.1.164.3.3.1.3.14
Maximum number of configurations that can be defined and stored in the DACS agent. If the DACS agent has a large capacity, the maximum will be limited to 254.
OBJECT-TYPE    
  Integer32  

sysSSelfTestResult 1.3.6.1.4.1.164.3.3.1.3.15
The test is performed by the active Common Logic card. The result will be a sum of 2**n according to the following bit convention: For DXC: bit 0 Database 1 Checksum Error (LSB) bit 1 Database 2 Checksum Error bit 2 I/O Expander Error bit 3 Counter Error bit 4 Matrix DPR Error bit 5 PS-A 5 Volt Error bit 6 PS-A 12 Volt Error bit 7 PS-B 5 Volt Error bit 8 PS-B 12 Volt Error bit 9 EPROM Failure For FCD: bit 0 I/O Expander Error (LSB) bit 1 Counter Error bit 2 EPROM Failure bit 3 Illegal Sys Config bit 4 SFIFO bit 5 EPIC Failure (ISDN) bit 6 XL Flash Fail -- for MSDSL interface bit 7 XL MITEL Fail -- for MSDSL interface bit 8 XL Framer Fail -- for MSDSL interface bit 9 XL DSP Fail -- for MSDSL interface For LRS52 - refer to product's spec When a bit is ('1'), the error exists. When NO ERROR is encountered, this object's value will be 0.
OBJECT-TYPE    
  Integer32  

sysSRelayState 1.3.6.1.4.1.164.3.3.1.3.16
Indicates the current state of the alarm relay. notApplicable - for agents that do not support this object.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

sysSInvertedAlr 1.3.6.1.4.1.164.3.3.1.3.17
Indicates if there is any Inverted alarm at any level of the system (sys, card, port). notApplicable - for agents that do not support this object.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

sysSRdnFlipTable 1.3.6.1.4.1.164.3.3.1.3.18
This table includes all the Flip events due to I/O Redundancy since last Clear command of this table.
OBJECT-TYPE    
  SEQUENCE OF  
    SysSRdnFlipEntry

sysSRdnFlipEntry 1.3.6.1.4.1.164.3.3.1.3.18.1
An entry in table.
OBJECT-TYPE    
  SysSRdnFlipEntry  

sysSRdnFlipIdx 1.3.6.1.4.1.164.3.3.1.3.18.1.1
Unique index number to identify an entry in the Redundancy Flip list.
OBJECT-TYPE    
  Integer32  

sysSRdnFlipSlot 1.3.6.1.4.1.164.3.3.1.3.18.1.2
The slot number from which Flip was performed.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

sysSRdnFlipPort 1.3.6.1.4.1.164.3.3.1.3.18.1.3
The port number from which Flip was performed. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 100=notApplicable (when Redundancy is at card level).
OBJECT-TYPE    
  Integer32  

sysSRdnFlipCause 1.3.6.1.4.1.164.3.3.1.3.18.1.4
The last cause that caused the Flip from the Slot (Port) of sysSRdnSlot, sysSRdnPort.
OBJECT-TYPE    
  DisplayString  

sysSRdnFlipDate 1.3.6.1.4.1.164.3.3.1.3.18.1.5
Flip event Date. The format will be the one selected by user for sysSDateFormat.
OBJECT-TYPE    
  DisplayString  

sysSRdnFlipTime 1.3.6.1.4.1.164.3.3.1.3.18.1.6
Flip event Time. The format will be hh:mm:ss.
OBJECT-TYPE    
  DisplayString  

sysSRdnFlipTableClearCmd 1.3.6.1.4.1.164.3.3.1.3.19
This command, when Set to 'on', clears the Redundancy Flip table (sysSRdnFlipTable). After clear is performed, the agent will turn the value to 'off' automatically.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSRdnFlipCmd 1.3.6.1.4.1.164.3.3.1.3.20
This object enables the user to send a command to the Agent, to Flip from a current Online IO card to its Redundant card. The value sent will be an Object Identifier of an entry in the sysCRdnTable. This entry defines the Redundant couple of Slots on which the Flip is applied. Setting this object, will cause the Agent to Flip from current Online card to its Redundant card. This manual flip command is applicable only for entries having Redundancy Mode=Y Cable. Agent will send the value 0 for Get.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

sysSBusTable 1.3.6.1.4.1.164.3.3.1.3.21
This table includes data and status about the internal DXC BUS.
OBJECT-TYPE    
  SEQUENCE OF  
    SysSBusEntry

sysSBusEntry 1.3.6.1.4.1.164.3.3.1.3.21.1
An entry in table.
OBJECT-TYPE    
  SysSBusEntry  

sysSBusPortIdx 1.3.6.1.4.1.164.3.3.1.3.21.1.1
The DXC BUS port number: - first two digits will be: (IO slot number+10) - last one/two digits will be the Bus port number, in odd numbers: port1 = 1 port2 = 3 Example: port2 of IO slot 11 will be: 213.
OBJECT-TYPE    
  Integer32  

sysSBusStatus 1.3.6.1.4.1.164.3.3.1.3.21.1.2
The Status of sysSBusPortIdx. free - not used physical - captured by the port of the card physically installed virtual - captured virtually by another port. Example: DIM port (by Destination) or by Transparent T3/E3 port.
OBJECT-TYPE    
  INTEGER free(1), physical(2), virtual(3)  

sysSBusCapturePort 1.3.6.1.4.1.164.3.3.1.3.21.1.3
The Port that Captured the sysSBusPortIdx. - if sysSBusStatus=free, the value will be 'none'=0 - else, if sysSBusStatus=fixed, the value will be: sysSBusPortIdx - else, the value will be according to the port index that captured this Bus Port (according to DXC port index convention): - xx1, xx3, xx11, xx13, xx31, xx33, xx2..xx56(even numbers) - xx = (IO slot number+10)
OBJECT-TYPE    
  Integer32  

sysSBusUtilization 1.3.6.1.4.1.164.3.3.1.3.21.1.4
Utilization of sysSBusPortIdx resources, in percent [%].
OBJECT-TYPE    
  Integer32  

sysSRdnCmdTable 1.3.6.1.4.1.164.3.3.1.3.22
This table includes commands used for IO Redundancy.
OBJECT-TYPE    
  SEQUENCE OF  
    SysSRdnCmdEntry

sysSRdnCmdEntry 1.3.6.1.4.1.164.3.3.1.3.22.1
An entry in table.
OBJECT-TYPE    
  SysSRdnCmdEntry  

sysSRdnEnforcedChannel 1.3.6.1.4.1.164.3.3.1.3.22.1.1
This is a command to override all switching considerations and enforce use of primary/ secondary connection only. noEnforcement - cancels the state of override and goes back to usual switching considerations. Default = noEnforcement(2).
OBJECT-TYPE    
  INTEGER notApplicable(1), noEnforcement(2), primary(3), secondary(4)  

sysCurrentAlr 1.3.6.1.4.1.164.3.3.1.4
OBJECT IDENTIFIER    

sysSAlrTable 1.3.6.1.4.1.164.3.3.1.4.1
List of system level current existing alarms .
OBJECT-TYPE    
  SEQUENCE OF  
    SysSAlrEntry

sysSAlrEntry 1.3.6.1.4.1.164.3.3.1.4.1.1
An entry in table.
OBJECT-TYPE    
  SysSAlrEntry  

sysSAlrIdx 1.3.6.1.4.1.164.3.3.1.4.1.1.1
An index number of the current system alarms.
OBJECT-TYPE    
  Integer32  

sysSAlrCode 1.3.6.1.4.1.164.3.3.1.4.1.1.2
This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
OBJECT-TYPE    
  Integer32  

sysSAlrState 1.3.6.1.4.1.164.3.3.1.4.1.1.3
This object indicates the alarm Severity.
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

sysSAlarmMask 1.3.6.1.4.1.164.3.3.1.4.1.1.4
Alarm Mask is : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlarmInvert 1.3.6.1.4.1.164.3.3.1.4.1.1.5
Alarm Invert is : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlarmOnOff 1.3.6.1.4.1.164.3.3.1.4.1.1.6
Alarm state is : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlarmCounter 1.3.6.1.4.1.164.3.3.1.4.1.1.7
A counter - how many times the alarm occured (ON) since last clear operation or since last Reset.
OBJECT-TYPE    
  Integer32  

sysSAlrClearCmd 1.3.6.1.4.1.164.3.3.1.4.2
Setting this attribute to ON, will enforce a clear operation on the system level alarms . Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlrClearAllCmd 1.3.6.1.4.1.164.3.3.1.4.3
Setting this attribute to ON, will enforce a clear operation on all levels alarms . Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlrMaskAll 1.3.6.1.4.1.164.3.3.1.4.4
on(3) - will cause masking of all the system level alarms. These alarms will not be sent to NMS and will not be taken into account for Alarms Status. off(2) - will unmask all system level alarms except those masked via the sysSAlrMask.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlrMask 1.3.6.1.4.1.164.3.3.1.4.5
This object is a mask that indicates which system level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the system level will be 0. This object is applicable only when sysSAlrMaskAll=off (otherwise all system alarms are masked). Example: When Alarms having the codes 6 and 11 are masked, the value of this object will be 840 (hex).
OBJECT-TYPE    
  OCTET STRING SIZE(8)  

sysSAlrDataUpdateCmd 1.3.6.1.4.1.164.3.3.1.4.6
on(3) - will cause Update of the Alarms Severity, Attributes and Report tables. off(2) - Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysBufferAlr 1.3.6.1.4.1.164.3.3.1.5
OBJECT IDENTIFIER    

sysBufferAlrTable 1.3.6.1.4.1.164.3.3.1.5.1
List of current existing alarms (of all levels).
OBJECT-TYPE    
  SEQUENCE OF  
    SysBufferAlrEntry

sysBufferAlrEntry 1.3.6.1.4.1.164.3.3.1.5.1.1
An entry in table.
OBJECT-TYPE    
  SysBufferAlrEntry  

sysBufferAlrIdx 1.3.6.1.4.1.164.3.3.1.5.1.1.1
An index number of the current alarms.
OBJECT-TYPE    
  Integer32  

sysBufferAlrCode 1.3.6.1.4.1.164.3.3.1.5.1.1.2
This object indicates a code related to a specific alarm description. The list of codes and thir related descriptions will be known by the NMS (for display purpose) and will appear in the unit's user manual.
OBJECT-TYPE    
  Integer32  

sysBufferAlrState 1.3.6.1.4.1.164.3.3.1.5.1.1.3
This object indicates the alarm type. minor/major/warning/critical - indicates appearance of the problem and the type. event - indicates occurence of an event. off - indicates disappearance of an alarm.
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

sysBufferAlrSlot 1.3.6.1.4.1.164.3.3.1.5.1.1.4
The slot number this alarm refers to. When the alarm refers to a system function OR the DACS agent is a stand-alone unit, the value will be 'notApplicable(255)'.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable(255)  

sysBufferAlrPort 1.3.6.1.4.1.164.3.3.1.5.1.1.5
The port number this alarm refers to. If the port number is irrelevant to this alarm (if it is a system/card level alarm) the value will be 9999.
OBJECT-TYPE    
  Integer32  

sysBufferAlrDate 1.3.6.1.4.1.164.3.3.1.5.1.1.6
The date when the alarm occured. The format will be according to sysSDateFormat.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

sysBufferAlrTime 1.3.6.1.4.1.164.3.3.1.5.1.1.7
The time when the alarm occured.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

sysBufferAlrClearCmd 1.3.6.1.4.1.164.3.3.1.5.2
Setting this attribute to ON, will enforce a clear operation on the Alarms Buffer. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysConfig 1.3.6.1.4.1.164.3.3.1.6
OBJECT IDENTIFIER    

sysCClkSrcTable 1.3.6.1.4.1.164.3.3.1.6.1
All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    SysCClkSrcEntry

sysCClkSrcEntry 1.3.6.1.4.1.164.3.3.1.6.1.1
An entry in table.
OBJECT-TYPE    
  SysCClkSrcEntry  

sysCClkCnfgIdx 1.3.6.1.4.1.164.3.3.1.6.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

sysCClkSrcIdx 1.3.6.1.4.1.164.3.3.1.6.1.1.2
An index in the table. There are only two entries in the table. master - refers Master clock parameters fallback - refers Fallback clock parameters
OBJECT-TYPE    
  INTEGER master(1), fallback(2)  

sysCClkSrcMode 1.3.6.1.4.1.164.3.3.1.6.1.1.3
This entry indicates the source the nodal timing is locked to. none - is an invalid option for Master clock. internal - is an invalid option for Fallback clock . station - is an invalid option for a stand-alone unit. lbt - loop-back timing ntr - A system locked reference clock adaptive - clcok locking is achieved by altering the clock according to the data load notApplicable - for ML source of Kmux or ML Timing combinations when Master/Fallback clock are not applicable.
OBJECT-TYPE    
  INTEGER none(1), internal(2), rxClk(3), station(4), lbt(5), ntr(6), adaptive(7), notApplicable(255)  

sysCClkSrcPrt 1.3.6.1.4.1.164.3.3.1.6.1.1.4
This entry is valid only when working in rxClk mode. For ACE2002 in case of invalid entry the return value will be 0. For other products in case of invalid entry the return value will be 9999. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The SP ports will be numbered as follows: - SP port 1 : 1 - SP port 2 : 2 For external ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For Kmux, the port will be according to : Slot*100+Ch. For ACE2002 and LA140, the port will be ifIndex.
OBJECT-TYPE    
  Integer32  

sysCClkStationFreq 1.3.6.1.4.1.164.3.3.1.6.1.1.5
This entry indicates the frequency of the station clock when the source is 'station'. The value will be applicable only when the sysCClkSrcMode is 'station'.
OBJECT-TYPE    
  INTEGER notApplicable(1), f1544Khz(2), f2048Khz(3)  

sysCClkRevertiveTimeout 1.3.6.1.4.1.164.3.3.1.6.1.1.6
The time in seconds in which the system will monitor the higher level clock source, before decision to revert to that clock. In case the time is zero, revertive mode will be disabled.
OBJECT-TYPE    
  Integer32  

sysCClkStationIf 1.3.6.1.4.1.164.3.3.1.6.1.1.7
This entry indicates the electrical interface connected to the station clock, when the source is 'station'. The value will be applicable only when the sysCClkSrcMode is 'station'.
OBJECT-TYPE    
  INTEGER notApplicable(1), g703(2), rs422(3)  

sysCnfgTable 1.3.6.1.4.1.164.3.3.1.6.2
All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    SysCnfgEntry

sysCnfgEntry 1.3.6.1.4.1.164.3.3.1.6.2.1
An entry in table.
OBJECT-TYPE    
  SysCnfgEntry  

sysCnfgIdx 1.3.6.1.4.1.164.3.3.1.6.2.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

sysCMatrixMode 1.3.6.1.4.1.164.3.3.1.6.2.1.2
Indicates the TS Matrix Mode: bidirectional - TS Assignment Matrix is symmetric. unidirectional - TS Assignment Matrix can be asymmetric. notApplicable - for agents that do not support this feature.
OBJECT-TYPE    
  INTEGER notApplicable(1), bidirectional(2), unidirectional(3)  

sysCIsdnFormat 1.3.6.1.4.1.164.3.3.1.6.2.1.3
ISDN format. This parameter controls the operation mode of the ISDN ports. te - ISDN timing is derived from the signal received from the equipment it is connected to. nt - timing of the transmit path is locked to the nodal timing source. notApplicable - for agents that do not support this feature.
OBJECT-TYPE    
  INTEGER notApplicable(1), te(2), nt(3)  

sysCRoutingOnEth 1.3.6.1.4.1.164.3.3.1.6.2.1.4
Mng Routing Protocol on the online CL Ethernet port.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

sysCAutoConfigEnable 1.3.6.1.4.1.164.3.3.1.6.2.1.5
This object enables user to enable/disable activating the Auto Configuration. When Auto Configuration is activated, the device learns its configuration Automatically from the Net it is connected to.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

sysCIntTsAllocMode 1.3.6.1.4.1.164.3.3.1.6.2.1.6
This object enables user to select the mode of Internal TS Allocation. static - user has to select for each Dynamic card port, the Maximum TSs expected to be connected (including future growth). This number will be allocated to the ports, so that if number of connected TSs will grow within the limits of this Maximum TS limit, no disruption of data flow will occur for other ports. dynamic- TS allocation is done dynamically according to the connected TSs. No future reservations are done. This mode may cause data disruption on other ports/slots if user will want to change the number of connected TSs for a Dynamic card port. Default=static(2).
OBJECT-TYPE    
  INTEGER notApplicable(1), static(2), dynamic(3)  

sysCRdnTable 1.3.6.1.4.1.164.3.3.1.6.3
Configuration of all Redundant I/O cards and ports. The write operation into the table objects is valid only for the TmpCnfg. A Slot/Port that have no Redundancy, will not exist in this table.
OBJECT-TYPE    
  SEQUENCE OF  
    SysCRdnEntry

sysCRdnEntry 1.3.6.1.4.1.164.3.3.1.6.3.1
An entry in table.
OBJECT-TYPE    
  SysCRdnEntry  

sysCRdnCnfgIdx 1.3.6.1.4.1.164.3.3.1.6.3.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32  

sysCRdnPrimeSlot 1.3.6.1.4.1.164.3.3.1.6.3.1.2
The slot number of the Primary card of Redundancy. The Primary card should be the card that user wishes to be the online card (usually the more important one). For some Redundancy modes the importance of the redundant cards/ports is the same.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

sysCRdnPrimePort 1.3.6.1.4.1.164.3.3.1.6.3.1.3
The port number. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 For IP Bundles, the value will be the Bundle ifIndex. For other products - refer to product specification. 100=notApplicable (when Redundancy is at card level).
OBJECT-TYPE    
  Integer32  

sysCRdnSecSlot 1.3.6.1.4.1.164.3.3.1.6.3.1.4
The slot number of the Secondary card of Redundancy matching the Primary slot.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

sysCRdnSecPort 1.3.6.1.4.1.164.3.3.1.6.3.1.5
The port number. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 For IP Bundles, the value will be the Bundle ifIndex. For other products - refer to product specification. 100=notApplicable (when Redundancy is at card level).
OBJECT-TYPE    
  Integer32  

sysCRdnMode 1.3.6.1.4.1.164.3.3.1.6.3.1.6
Redundancy Mode. DXC supports: yCable(3), singleSlotProtection(6) and dualCableParallelTx(4) MP supports: dualCableAIS(2), yCable(3), dualCableParallelTx(4) and backup(5). backup - will be used when a port is backup of more than one port. IPmux: onePlusOne(7) and oneToOne(8) use for Bundle redundancy.
OBJECT-TYPE    
  INTEGER dualCableAIS(2), yCable(3), dualCableParallelTx(4), backup(5), singleSlotProtection(6), onePlusOne(7), oneToOne(8)  

sysCRdnRecMode 1.3.6.1.4.1.164.3.3.1.6.3.1.7
Recovery Mode. This object determines if after recovery of the failed card/port it will become on-line again or not: auto - automatic . In this case, the failed card/port will become on-line again after recovery, automatically. manual - In this case, the failed card/port will not become on-line again after recovery.
OBJECT-TYPE    
  INTEGER auto(2), manual(3)  

sysCRdnRecTime 1.3.6.1.4.1.164.3.3.1.6.3.1.8
Redundancy Recovery Time (sec). After switching to the current online card, the next switch can be performed only after a minimum time, indicated by this object. This object is applicable only when sysCRdnRecMode=auto.
OBJECT-TYPE    
  Integer32 1..99  

sysCRdnHwSwFlip 1.3.6.1.4.1.164.3.3.1.6.3.1.9
HW or SW decision for Redundancy Flip. This object is applicable only for sysCRdnMode=singleSlotProtection. HW - decision is by I/O card SW - decision is by CL SW.
OBJECT-TYPE    
  INTEGER notApplicable(1), hw(2), sw(3)  

sysCRdnRowStatus 1.3.6.1.4.1.164.3.3.1.6.3.1.10
This parameter allows NMS to create/delete entries of this table. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

sysCRdnOnline 1.3.6.1.4.1.164.3.3.1.6.3.1.11
Status - who is the Online (current) Redundancy Slot/Port. This object shows only the Online Slot/Port regarding the Redundancy. mdlSActivity or prtGenActiveStatus of the same Slot/Port may be Offline.
OBJECT-TYPE    
  INTEGER notApplicable(1), primary(2), secondary(3)  

sysCRdnSwitchingMode 1.3.6.1.4.1.164.3.3.1.6.3.1.12
This object defines which Self Healing Ring (SHR) SDH ring is used: Uni Directional or BiDirectional. The type of the ring is defined according to the direction of traffic flow under normal working conditions. In Bi Directional ring, the duplex traffic is on the same path and transverses the same set of nodes for both directions of transmission. In Uni Directional ring, the duplex traffic travels over opposite path (per direction) and all the node of the ring are involved. For Uni Directional SHR Protection Switching (Single Ended Switching) is controlled by one node of the SDH ring, and does not require a protocol. For Bi Directional SHR Protection Switching (Dual Ended switching) is controlled by some nodes of the ring and requires a protocol
OBJECT-TYPE    
  INTEGER notApplicable(1), biDirectional(2), uniDirectional(3)  

sysCRdnFlipUponEvent 1.3.6.1.4.1.164.3.3.1.6.3.1.13
This object allows user to define if Flip to the other port will be performed (or not), for certain possible events. Each event is represented by a bit. The value of the object is a sum of 2**n, according to the bits having '1' value. '1' - means that Flip should occur due to this event. Bit 0 (LSB) = SD (Signal Degraded). For IPmux: Bit 0 (LSB) = TDM Line LOS/LOF. Bit 1 = Sequence Number. Bit 2 = Jitter Buffer errors.
OBJECT-TYPE    
  Integer32  

sysCRdnLosOrLofTime 1.3.6.1.4.1.164.3.3.1.6.3.1.14
This parameter determines how much time to wait before switching, after LOF or LOS are detected on the TDM Line. For Ipmux time is counted in msec.
OBJECT-TYPE    
  Integer32  

sysCRdnEventsTimeWindow 1.3.6.1.4.1.164.3.3.1.6.3.1.15
This parameter determines the time window in which to count events to trigger protection switching. For Ipmux time is counted in seconds.
OBJECT-TYPE    
  Integer32  

sysCRdnSequenceNumberThreshold 1.3.6.1.4.1.164.3.3.1.6.3.1.16
This parameter determines the number of Sequence Number errors that should occur in the time window in order to cause switching.
OBJECT-TYPE    
  Integer32  

sysCRdnBufferErrorsThreshold 1.3.6.1.4.1.164.3.3.1.6.3.1.17
This parameter determines the number of Buffer undeflow/ overflow events occured in the time window that cause switching.
OBJECT-TYPE    
  Integer32  

sysCRdnBuffUnderrunTime 1.3.6.1.4.1.164.3.3.1.6.3.1.18
This parameter determines how much time to wait before switching, after jitter buffer underrun. Switching occurs if no frame arrives within that time. For Ipmux time is counted in msec.
OBJECT-TYPE    
  Integer32  

sysDbase 1.3.6.1.4.1.164.3.3.1.7
OBJECT IDENTIFIER    

sysDbaseSanityCheckCmd 1.3.6.1.4.1.164.3.3.1.7.1
Setting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysDbaseDownloadCnfgIdxCmd 1.3.6.1.4.1.164.3.3.1.7.2
This attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command, the DACS agent will initiate the Sanity-Check process. If successful, the actual transfer will be performed. If there will be errors, the user will have to perform the command again after errors correction. The operation is valid only on configuration numbers that do not exceed sysSMaxNoOfCnfg.
OBJECT-TYPE    
  Integer32 1..255  

sysDbaseUploadCnfgIdxCmd 1.3.6.1.4.1.164.3.3.1.7.3
This attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on configuration numbers that do not exceed sysSMaxNoOfCnfg.
OBJECT-TYPE    
  Integer32 1..255  

sysDbaseFlipTable 1.3.6.1.4.1.164.3.3.1.7.4
Dbase Flip time and activation for every configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    SysDbaseFlipEntry

sysDbaseFlipEntry 1.3.6.1.4.1.164.3.3.1.7.4.1
An entry in table.
OBJECT-TYPE    
  SysDbaseFlipEntry  

sysDbaseFlipIdx 1.3.6.1.4.1.164.3.3.1.7.4.1.1
This attribute indicates the Idx of the Cnfg being the target Configuration.
OBJECT-TYPE    
  Integer32 1..255  

sysDbaseFlipTime 1.3.6.1.4.1.164.3.3.1.7.4.1.2
This attribute indicates the time (HH:MM) when this data base will start being used by the Tmp config.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

sysDbaseFlipActivation 1.3.6.1.4.1.164.3.3.1.7.4.1.3
This attribute indicates if the Dbase flip will be activated at the time specified for this configuration (enable) or not (disable). No more than one flip should be enabled for the same time.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

mdlDacsMux 1.3.6.1.4.1.164.3.3.2
OBJECT IDENTIFIER    

mdlGen 1.3.6.1.4.1.164.3.3.2.1
OBJECT IDENTIFIER    

mdlSTable 1.3.6.1.4.1.164.3.3.2.1.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlSEntry

mdlSEntry 1.3.6.1.4.1.164.3.3.2.1.1.1
An entry in table.
OBJECT-TYPE    
  MdlSEntry  

mdlSSltIdx 1.3.6.1.4.1.164.3.3.2.1.1.1.1
A unique number to identify a slot position in the DACS. The Kilomux should use enumerated values starting with kmx.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlSCardType 1.3.6.1.4.1.164.3.3.2.1.1.1.2
This attribute indicates the type of the card installed in the specific slot position. Only PS's are possible in the PS slots. Only CL's are possible in the CL slots. Only IO modules are possible in the IO slots. Kmux card type start with the letter k. LA card type start with the letters la.
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), psAC(10), psDC(11), dCl(20), kCl(21), dcl2(22), dcl2Eth(23), kClEth(24), dcl3(25), dcl3Eth(26), d4T1(28), d8T1(29), dT1DSU(30), dT1CSU(31), dE1DSU(32), dE1LTU(33), dE1aDSU(34), dE1aLTU(35), dT1F(36), dE1F(37), d4E1(38), d8E1(39), dE1Hdsl(40), dT1Hdsl(41), dE1HdslS(42), dT1HdslS(43), d16gsdsl(44), d8sl(45), kML1(50), kML2(51), kML3(52), kML4(53), kML5(54), kML6(55), kML7(56), kML8(57), kML10(59), kMLF(60), kML10New(61), kML11RJ45(62), kML11FO(63), kLS1(70), kLS1New(71), kLS2(72), kTRE(80), kMBE(81), kMBENew(82), fLAN(83), kai(90), kdi(91), kdiCH(92), dHS2(100), d8U(101), d16U(102), kHS1(110), kHS2(111), kHSU1(112), kHSU2(113), kHS703(114), kVC1EM(130), kVC1FXO(131), kVC1FXS(132), kVC1MEM(133), kVC1MFXO(134), kVC1MFXS(135), kVC1MFXSW(136), kVC2EM(137), kVC2FXO(138), kVC2FXS(139), kVC2s1EM(140), kVC2s1FXO(141), kVC2s1FXS(142), kVC3EM(143), kVC3FXO(144), kVC3FXS(145), kVC3S0(146), kVF1EM(170), kVF1FXO(171), kVF1FXS(172), kVF3EM(173), kVF3FXO(174), kVF3FXS(175), kVF4EM(176), kVF4FXO(177), kVF4FXS(178), kVF4FXSW(179), kVF4S0(180), kVF5PbxE1(181), kVF5E1PbxSlave(182), kVF5PbxT1(183), kVF5T1PbxSlave(184), kVF5PbxE1New(185), kVF5E1PbxSlaveNew(186), kVF5PbxT1New(187), kVF5T1PbxSlaveNew(188), kVF4FXO3(189), kVF4FXS3(190), kVF4NS0(191), kVF6E1s16(192), kVF6E1s31(193), kVF6T1s12(194), kVF6T1s24(195), kVF8EM(196), kVF8FXO(197), kVF8FXS(198), dimV35(201), dimRS422(202), dimRS530(203), dimHssi(204), dimX21(205), dim10BaseT(206), dimE1(207), dim100(208), dt3G747(209), dt3(210), dt3f(211), de3(212), de3f(213), dstm1s1(214), dstm1s2(215), fSTM1(216), dstm1(217), dstm1R(218), f2stm1(219), laSUB(230), laVEM(231), laVFXO(232), laVFXS(233), laV11(234), laV24(235), laV35(236), laT1(237), laT1Vxx(238), laE1(239), laE1Vxx(240), laISDN(241), laVxx(242), laEth(243), laISDNwBU(244), laIsdnNT(245), laIsdnNTwBU(246), laIsdnTE(247), laFXSwBU(248), laFXSs(249), laFXSwBUs(250), laIsdnNTs(251), laIsdnNTwBUs(252), laIsdnTEs(253), laDp(254), laSdsl(255), laSdslDp(256), laAdslA(257), laAdslADp(258), laAdslB(259), laAdslBDp(260), laShdsl(261), laShdslDp(262), laT1b(263), laT1bDp(264), laIsdnTEwBU(265), laIsdnTEwBUs(266)  

mdlSHwVer 1.3.6.1.4.1.164.3.3.2.1.1.1.3
This attribute indicates the Hardware version of the card installed in the specific slot position.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

mdlSSwVer 1.3.6.1.4.1.164.3.3.2.1.1.1.4
This attribute indicates the Software version of the card installed in the specific slot position.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

mdlSAlarmStatus 1.3.6.1.4.1.164.3.3.2.1.1.1.5
Indicates the current alarm state only for card level. This object will be set to: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4), event(5), warning(6), critical(7)  

mdlSAlarmStatusAll 1.3.6.1.4.1.164.3.3.2.1.1.1.6
Indicates the current card alarm state including the lower level: card, port. This object will be set to: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4), event(5), warning(6), critical(7)  

mdlSTestStatus 1.3.6.1.4.1.164.3.3.2.1.1.1.7
This attribute will be on(3) when there is at least one test running on a port of the module; otherwise the value will be off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSHwStatus 1.3.6.1.4.1.164.3.3.2.1.1.1.8
This attribute will be fail(2) when a HW FAIL exists on this module (discovered by periodic self test); otherwise the value will be ok(3).
OBJECT-TYPE    
  INTEGER fail(2), ok(3)  

mdlSActivity 1.3.6.1.4.1.164.3.3.2.1.1.1.9
notApplicable - when the slot is empty (no module) offline(1) - when the module is not active (redundant) online (2) - when the module is active .
OBJECT-TYPE    
  INTEGER notApplicable(1), offline(2), online(3)  

mdlSAlrClearCmd 1.3.6.1.4.1.164.3.3.2.1.1.1.10
Setting this attribute to ON, will enforce a clear operation on the card level alarms . Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrClearAllCmd 1.3.6.1.4.1.164.3.3.2.1.1.1.11
Setting this attribute to ON, will enforce a clear operation on card and port level alarms . Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrMaskAll 1.3.6.1.4.1.164.3.3.2.1.1.1.12
on(3) - will cause masking of all the card level alarms. These alarms will not be sent to NMS and will not be taken into account for Alarms Status. off(2) - will unmask all card level alarms except those masked via the mdlAlrMaskTable.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSCmd 1.3.6.1.4.1.164.3.3.2.1.1.1.13
General object for any special command at card level. 0=NotApplicable, for cards that don't support this object. For KML.10(ISDN) card of KM-2100, the object will indicate Manual Call Command in Switch mode. It is applicable only when for KML.10, prtIsdnSwitchMode=manual. KML.10 valid values: '1' = noOp, will be used by agents that do not support this feature or object (old KM agents) '2' = off, Set call command mode to disconnect state. Disconnects the call. '3' = on, Set call command mode to connect state. Connects the call. For DXC IO cards, the object will be used for IO Card Reset HW command: '2' = off, this will be always the Get value for these cards. '3' = on, this is the Set command used to Reset the IO card. Upon completing the operation, the value will automatically change to off(2), by Agent. For Slots that are NOT IO Slots and for empty IO Slots, the Get value will be always '0' (NotApplicable).
OBJECT-TYPE    
  Integer32  

mdlSReset 1.3.6.1.4.1.164.3.3.2.1.1.1.14
Reset action to be performed on the module.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSRebuildFrame 1.3.6.1.4.1.164.3.3.2.1.1.1.15
Applicable only for KiloMux Main Link cards only. '2' = off, this will be always the Get value. '3' = on, this is the Set command used to Rebuild the Frame. Upon completing the operation, the value will automatically change to off(2), by Agent.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

mdlCTable 1.3.6.1.4.1.164.3.3.2.1.2
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlCEntry

mdlCEntry 1.3.6.1.4.1.164.3.3.2.1.2.1
An entry in table.
OBJECT-TYPE    
  MdlCEntry  

mdlCConfigIdx 1.3.6.1.4.1.164.3.3.2.1.2.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch).
OBJECT-TYPE    
  Integer32 1..255  

mdlCSlotIdx 1.3.6.1.4.1.164.3.3.2.1.2.1.2
This object indicates a unique number of the slot position in which the module is inserted. The Kilomux should use enumerated values starting with kmx.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlCProgCardType 1.3.6.1.4.1.164.3.3.2.1.2.1.3
This object indicates the card type assigned to the specific slot in the common configuration. This object is identical for all the configurations (1..255). Only the TmpCnf(255) might have a different value. The write operation is valid only for the TmpCnfg entry.
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), psAC(10), psDC(11), dCl(20), kCl(21), dcl2(22), dcl2Eth(23), kClEth(24), dcl3(25), dcl3Eth(26), d4T1(28), d8T1(29), dT1DSU(30), dT1CSU(31), dE1DSU(32), dE1LTU(33), dE1aDSU(34), dE1aLTU(35), dT1F(36), dE1F(37), d4E1(38), d8E1(39), dE1Hdsl(40), dT1Hdsl(41), dE1HdslS(42), dT1HdslS(43), d16gsdsl(44), d8sl(45), kML1(50), kML2(51), kML3(52), kML4(53), kML5(54), kML6(55), kML7(56), kML8(57), kML10(59), kMLF(60), kML10New(61), kML11RJ45(62), kML11FO(63), kLS1(70), kLS1New(71), kLS2(72), kTRE(80), kMBE(81), kMBENew(82), fLAN(83), kai(90), kdi(91), kdiCH(92), dHS2(100), d8U(101), d16U(102), kHS1(110), kHS2(111), kHSU1(112), kHSU2(113), kHS703(114), kVC1EM(130), kVC1FXO(131), kVC1FXS(132), kVC1MEM(133), kVC1MFXO(134), kVC1MFXS(135), kVC1MFXSW(136), kVC2EM(137), kVC2FXO(138), kVC2FXS(139), kVC2s1EM(140), kVC2s1FXO(141), kVC2s1FXS(142), kVC3EM(143), kVC3FXO(144), kVC3FXS(145), kVC3S0(146), kVF1EM(170), kVF1FXO(171), kVF1FXS(172), kVF3EM(173), kVF3FXO(174), kVF3FXS(175), kVF4EM(176), kVF4FXO(177), kVF4FXS(178), kVF4FXSW(179), kVF4S0(180), kVF5PbxE1(181), kVF5E1PbxSlave(182), kVF5PbxT1(183), kVF5T1PbxSlave(184), kVF5PbxE1New(185), kVF5E1PbxSlaveNew(186), kVF5PbxT1New(187), kVF5T1PbxSlaveNew(188), kVF4FXO3(189), kVF4FXS3(190), kVF4NS0(191), kVF6E1s16(192), kVF6E1s31(193), kVF6T1s12(194), kVF6T1s24(195), kVF8EM(196), kVF8FXO(197), kVF8FXS(198), dimV35(201), dimRS422(202), dimRS530(203), dimHssi(204), dimX21(205), dim10BaseT(206), dimE1(207), dim100(208), dt3G747(209), dt3(210), dt3f(211), de3(212), de3f(213), dstm1s1(214), dstm1s2(215), fstm1(216), dstm1(217), dstm1R(218), f2stm1(219)  

mdlCNoOfExtPrt 1.3.6.1.4.1.164.3.3.2.1.2.1.4
Number of external ports in the programmed module of the specific slot position
OBJECT-TYPE    
  Integer32  

mdlCNoOfIntPrt 1.3.6.1.4.1.164.3.3.2.1.2.1.5
Number of internal ports in the programmed module of the specific slot position.
OBJECT-TYPE    
  Integer32  

mdlCParam 1.3.6.1.4.1.164.3.3.2.1.2.1.6
General configuration object at card level (per configuration). NotApplicable=0, for cards that don't support this object. For D8U and D16U cards of DXC, the object will indicate the port on which BERT will be performed. The port can be one of the external ports, any of its associated B1, B2, D ports or no port of the card (None=0). For port indexes see DXC R6 spec.
OBJECT-TYPE    
  Integer32  

mdlAlr 1.3.6.1.4.1.164.3.3.2.1.3
OBJECT IDENTIFIER    

mdlAlrTable 1.3.6.1.4.1.164.3.3.2.1.3.1
The list of card alarms.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlAlrEntry

mdlAlrEntry 1.3.6.1.4.1.164.3.3.2.1.3.1.1
An entry in table.
OBJECT-TYPE    
  MdlAlrEntry  

mdlAlrIdx 1.3.6.1.4.1.164.3.3.2.1.3.1.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive
OBJECT-TYPE    
  Integer32  

mdlAlrSltIdx 1.3.6.1.4.1.164.3.3.2.1.3.1.1.2
This attribute indicates the desired slot position. The Kilomux should use enumerated values starting with kmx.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlAlrCode 1.3.6.1.4.1.164.3.3.2.1.3.1.1.3
This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
OBJECT-TYPE    
  Integer32  

mdlAlrState 1.3.6.1.4.1.164.3.3.2.1.3.1.1.4
This object indicates the card alarm severity.
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

mdlAlarmMask 1.3.6.1.4.1.164.3.3.2.1.3.1.1.5
Alarm Mask is : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlAlarmInvert 1.3.6.1.4.1.164.3.3.2.1.3.1.1.6
Alarm Invert is : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlAlarmOnOff 1.3.6.1.4.1.164.3.3.2.1.3.1.1.7
Alarm state is : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlAlarmCounter 1.3.6.1.4.1.164.3.3.2.1.3.1.1.8
A counter - how many times the alarm occured (ON) since last clear operation or since last Reset.
OBJECT-TYPE    
  Integer32  

mdlAlrMaskTable 1.3.6.1.4.1.164.3.3.2.1.3.2
The list of card masked alarms.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlAlrMaskEntry

mdlAlrMaskEntry 1.3.6.1.4.1.164.3.3.2.1.3.2.1
An entry in table.
OBJECT-TYPE    
  MdlAlrMaskEntry  

mdlAlrMaskSltIdx 1.3.6.1.4.1.164.3.3.2.1.3.2.1.1
This attribute indicates the desired slot position. The Kilomux should use enumerated values starting with kmx.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlAlrMask 1.3.6.1.4.1.164.3.3.2.1.3.2.1.2
This object is a mask that indicates which card level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the card level will be 0. This object is applicable only when mdlSAlrMaskAll=off (otherwise all card alarms are masked). Example: When Alarm having the code 8 is masked, the value of this object will be 100 (hex).
OBJECT-TYPE    
  OCTET STRING SIZE(8..10)  

mdlCl 1.3.6.1.4.1.164.3.3.2.2
OBJECT IDENTIFIER    

mdlClTable 1.3.6.1.4.1.164.3.3.2.2.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlClEntry

mdlClEntry 1.3.6.1.4.1.164.3.3.2.2.1.1
An entry in table.
OBJECT-TYPE    
  MdlClEntry  

mdlClIdx 1.3.6.1.4.1.164.3.3.2.2.1.1.1
This object indicates the Cl slot referred.
OBJECT-TYPE    
  INTEGER clA(3), clB(4)  

mdlClSwchStatus 1.3.6.1.4.1.164.3.3.2.2.1.1.2
This object indicates the status of the switches on the referred DCL card. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits. There are 4 switches: bit 0 SP-PAR (LSB) '1' - Default parameters bit 1 PSWRD '1' - Password=default '0' - Password=user selected bit 2 DB-INIT '1' - DB initiated with default '0' - DB initiated with NVRAM contents bit 3 PC-SP (MSB) '1' - Management by terminal only '0' - Management by NMS Example: If SP-PAR and PSWRD bits are set ('1'), the value will be 3 (2**1 + 2**0). When the status of the switches is unknown, the value of this object will be 255.
OBJECT-TYPE    
  Integer32  

mdlClLastFlipDate 1.3.6.1.4.1.164.3.3.2.2.1.1.3
Date when last flip occured. The format would be as specified by the sysSDateFormat.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

mdlClLastFlipTime 1.3.6.1.4.1.164.3.3.2.2.1.1.4
Time when last flip occured.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

mdlClLastFlipCause 1.3.6.1.4.1.164.3.3.2.2.1.1.5
The cause of last flip.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

mdlPs 1.3.6.1.4.1.164.3.3.2.3
OBJECT IDENTIFIER    

mdlPsTable 1.3.6.1.4.1.164.3.3.2.3.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlPsEntry

mdlPsEntry 1.3.6.1.4.1.164.3.3.2.3.1.1
An entry in table.
OBJECT-TYPE    
  MdlPsEntry  

mdlPsIdx 1.3.6.1.4.1.164.3.3.2.3.1.1.1
This object indicates the PS card referred.
OBJECT-TYPE    
  INTEGER psA(1), psB(2)  

mdlPsStatus 1.3.6.1.4.1.164.3.3.2.3.1.1.2
This object indicates the status of the PS card.
OBJECT-TYPE    
  INTEGER notActive(1), active(2)  

mdlPsTestResult 1.3.6.1.4.1.164.3.3.2.3.1.1.3
This object indicates the result of the PS card test. ok (1) - the test passed successfully. f12V (2) - 12V FAIL was detected f5V (3) - 5V FAIL was detected.
OBJECT-TYPE    
  INTEGER ok(1), f12V(2), f5V(3)  

prtDacsMux 1.3.6.1.4.1.164.3.3.3
OBJECT IDENTIFIER    

prtGen 1.3.6.1.4.1.164.3.3.3.1
OBJECT IDENTIFIER    

prtGenParamTable 1.3.6.1.4.1.164.3.3.3.1.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenEntry

prtGenEntry 1.3.6.1.4.1.164.3.3.3.1.1.1
An entry in table.
OBJECT-TYPE    
  PrtGenEntry  

prtGenPrtIdx 1.3.6.1.4.1.164.3.3.3.1.1.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
OBJECT-TYPE    
  Integer32  

prtGenSlt 1.3.6.1.4.1.164.3.3.3.1.1.1.2
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used. The Kilomux should use the enumerated starting with kmx.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), standAlone(255)  

prtGenExtInt 1.3.6.1.4.1.164.3.3.3.1.1.1.3
This attribute describes the type of the designated port. Exteral port is a port with a physical connector. Internal port might be of two types, one is a composite port which collects data of a few external ports into a common bandwidth (usually routed trough DS1 link); the other type is internal ports which get only part of external port data (usually a few DS0's). In the Kilomux-2100, the internal(3) value is used for composite channels or sub-channels of an ISDN Ch.
OBJECT-TYPE    
  INTEGER external(2), internal(3)  

prtGenIfIndex 1.3.6.1.4.1.164.3.3.3.1.1.1.4
This attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx, the value will be '7fffffff'h.
OBJECT-TYPE    
  Integer32  

prtGenActiveStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.5
This attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the port is not connected according to the active config. offLine(3) indicates that the port is down (not working) due to any problem. onLine (4) indicates that the port is up (working) offLineRedundancy(5) indicates that the port is down because it is a redundant port. onLineRedundancy (6) indicates that this is a redundant port which is up and works as the active link.
OBJECT-TYPE    
  INTEGER unknown(1), notUsed(2), offLine(3), onLine(4), offLineRedundancy(5), onLineRedundancy(6)  

prtGenAlrStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.6
Indicates the alarm state at port (ch) agent level. This object will be: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4), event(5), warning(6), critical(7)  

prtGenTestStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.7
This attribute will be on(3) when there is at least one test in progress (running) on the port; otherwise the value will be off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtGenTestMask 1.3.6.1.4.1.164.3.3.3.1.1.1.8
This is a mask which indicates which tests from the 'prtGenTestCmd' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
OBJECT-TYPE    
  Integer32  

prtGenTestCmd 1.3.6.1.4.1.164.3.3.3.1.1.1.9
Setting this object to a value as detailed furter on (except 0) will initiate a test on the specific port, if the operation is allowed (according to TestMask). If the operation is not allowed, the mux will ignore the operation. The test/s requested will be set according to the respective bit: TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the requested value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the requested tests are : local-loop remote-loop Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port; it will NOT stop the tests initiated by the system.
OBJECT-TYPE    
  Integer32  

prtGenTestRunning 1.3.6.1.4.1.164.3.3.3.1.1.1.10
This object indicates which tests are running currently on the selected port (initiated by user and/or by the system). If a specific test is currently running on the port, its respective bit will be SET: TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 llb 5 txInband 6 rxInband 7 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 DDS DSU loop 11 DDS CSU loop 12 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 Local DTE loop (HSSI)17 Local Line loop (HSSI)18 Remote Line loop (HSSI)19 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Network Line Loopback 24 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the running tests are : local-loop remote-loop llb (Bit 5) - can be initiated by system only!
OBJECT-TYPE    
  Integer32  

prtGenType 1.3.6.1.4.1.164.3.3.3.1.1.1.11
This object describes the type of the selected port. idsl - applicable for external ports of HS-U cards (of DXC) when interface is LT-1.
OBJECT-TYPE    
  INTEGER unknown(1), t1(2), e1(3), hs(4), t1Csu(5), t1Dsu(6), e1Ltu(7), e1Dsu(8), hdsl(9), sp(10), t1F(11), e1F(12), dim(13), isdn(14), t3(15), e3(16), t3f(17), e3f(18), idsl(19), stm1(20), vc4(21), vc12(22), msdsl(23), vc11(24), vc3(25), soh(26), eth(27), shdsl(28), other(255)  

prtGenInterfaceType 1.3.6.1.4.1.164.3.3.3.1.1.1.12
This attribute indicates a unique HW interface type of the selected port. Examples: - for T1 cards: DSU, CSU - for E1 cards: DSU, LTU - for HS cards: v35, rs422, x21 etc...
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

prtGenAlrClearCmd 1.3.6.1.4.1.164.3.3.3.1.1.1.13
Setting this attribute to ON, will enforce a clear operation on the port level alarms . Upon completion, the value will automatically change to off(2). noOp - will be used by agents that do not support this feature or object.
OBJECT-TYPE    
  INTEGER noOp(1), off(2), on(3)  

prtGenAlrMaskAll 1.3.6.1.4.1.164.3.3.3.1.1.1.14
on(3) - will mask all the alarms of the selected port off(2)- will unmask all alarms of the selected port except the ones selected by the prtAlrMaskTable. noOp - will be used by agents that do not support this feature or object.
OBJECT-TYPE    
  INTEGER noOp(1), off(2), on(3)  

prtGenParamStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.15
This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For HS cards (Dxc cards) - 1 octet: Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 0 and 1 indicates RTS control signal state: Bit 1: '1'=active ; '0'=notActive Bit 0 (LSB): '1'=unknown ; '0'=NA - For HS-U/1 external port (MP card, used in FCD-M) - 1 Octet: Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For VC-6, VC-12, VC-12/6 external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=Unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For KM2100, KVF.5 cards - indicates the status of A and B signaling for each internal channel. 1 Octet: Bit - 7 6 5 4 3 2 1 0 |_____| |_| |_| spare B A Bit 0 (LSB) and Bit 1 : A status Bit 2 and Bit 3 : B status 00 - Off 01 - On 11 - Unknown - For FCD-W, NETWORK and USER ports - 1 Octet Status of Control Signals: '1'=On ; '0'=Off or when not applicable Bit - 7 6 5 4 3 2 1 0 Bit 7 (MSB) - Signal Loss (applicable only for G.703 interface) Bit 6 - CONTROL (applicable only for X.21 interface) Bit 5 - INDICATION (applicable only for X.21 interface) Bit 4 - DSR (applicable only for V.35 interface) Bit 3 - RTS (applicable only for V.35 interface) Bit 2 - CTS (applicable only for V.35 interface) Bit 1 - DTR (applicable only for V.35 interface) Bit 0 - DCD (applicable only for V.35 interface) - For DXC R6 , D8U, D16U External ports - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For DXC DE1-HDSL, DT1-HDSL, D16GSDSL, D8SL External ports - 2 Octets MSB octet: far-end modem channel interface LSB octet: Sub Link existence (Y/N), far-end modem type, synchronization with far-end modem MSB octet: 0000 0000 = no interface 0000 0001 = db15 (X21) 0000 0010 = IR-IP 0000 0011 = IR-ETH-Q 0000 0100 = V35 0000 0101 = ETH-RJ45 0000 0110 = G703 0000 0111 = db25 (RS530) 0000 1000 = ETH-BNC 0000 1001 = E1(Balanced) 0000 1010 = E1(Unbalanced) Rest of the combinations: reserved LSB octet: Bit 7 6 5 4 3 2 1 0 LSB | |___________| |__| SL modem sync or Box material SL: modem: 00000 = other sync: 00 = not sync 0=not exist 00001 = unknown 01 = sync 1=exists 00010 = ASMi-31/2 10 = reserved 00011 = HCD-E1 11 = reserved Box material 00100 = HTU-E1 (for D8SL card): 00101 = HTU-2 0=metal 00110 = ASMi-52 SA/2W/Slave 1=plastic 00111 = ASMi-52 SA/2W/Master 01000 = ASMi-52/CQ card of LRS-24 01001 = ASMi-52/CD card of LRS-24 01010 = D16GSDSL card of DXC-3000 01011 = LRS-52 01100 = FCD 01110 = D8GSDSL card of DXC-3000 Rest = reserved
OBJECT-TYPE    
  OCTET STRING  

prtGenRdnStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.16
This object indicates if this port is part of a redundant pair and in this case, if it is On or Off. none(1) - No redundancy or Not Applicable off (2) - the port is part of a redundant pair and it is Off from Redundancy point of view (not the port used). on (3) - the port is part of a redundant pair and it is On from Redundancy point of view (it is the port used).
OBJECT-TYPE    
  INTEGER none(1), off(2), on(3)  

prtGenTestMaskXP 1.3.6.1.4.1.164.3.3.3.1.1.1.17
This is an Expanded test mask of the prtGenTestMask object. The prtGenTestMask object reached its maximum, being an Integer with 31 bits. This object indicates which tests from the 'prtGenTestCmdXP' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
OBJECT-TYPE    
  OCTET STRING  

prtGenTestCmdXP 1.3.6.1.4.1.164.3.3.3.1.1.1.18
This is an Expanded test command of the prtGenTestCmd object. The prtGenTestCmd object reached its maximum, being an Integer with 31 bits. Setting this object to a value as detailed furter on (except 0) will initiate a test on the specific port, if the operation is allowed (according to TestMaskXP). If the operation is not allowed, the mux will ignore the operation. The test/s requested will be set according to the respective bit: TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 e.g : If the requested value is 00000003 hex -> Bits 1 & 2 are set -> the requested tests are : local-loop remote-loop Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port; it will NOT stop the tests initiated by the system.
OBJECT-TYPE    
  OCTET STRING  

prtGenTestRunningXP 1.3.6.1.4.1.164.3.3.3.1.1.1.19
This is an Expanded object of the prtGenTestRunning object. The prtGenTestRunning object reached its maximum, being an Integer with 31 bits. This object indicates which tests are running currently on the selected port (initiated by user and/or by the system). If a specific test is currently running on the port, its respective bit will be SET: TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 llb 5 txInband 6 rxInband 7 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 DDS DSU loop 11 DDS CSU loop 12 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 Local DTE loop (HSSI)17 Local Line loop (HSSI)18 Remote Line loop (HSSI)19 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Network Line Loopback 24 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the running tests are : local-loop remote-loop llb (Bit 5) - can be initiated by system only!
OBJECT-TYPE    
  OCTET STRING  

prtGenTestDurationTable 1.3.6.1.4.1.164.3.3.3.1.2
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenTestDurationEntry

prtGenTestDurationEntry 1.3.6.1.4.1.164.3.3.3.1.2.1
An entry in table.
OBJECT-TYPE    
  PrtGenTestDurationEntry  

prtGenTestPrtIdx 1.3.6.1.4.1.164.3.3.3.1.2.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
OBJECT-TYPE    
  Integer32  

prtGenTestIdx 1.3.6.1.4.1.164.3.3.3.1.2.1.2
This attribute indicates the test, the duration refers.
OBJECT-TYPE    
  INTEGER localLoop(1), remoteLoop(2), bert(3), plb(4), rlb(5), llb(6), toneInjection(7), txInband(8), rxInband(9), remLoopOnRemUnit(10), bertOnRemUnit(11), llbOnRemUnit(12), txPlb(14), txLlb(15), dteLoop(16), hdslTxInband(20), hdslRxInband(21), monitor(22), userLineLoopback(23), lbbd(26), lb1(27), lb2(28), tsRemoteLoop(30), downstreamAis(32), upstreamAis(33), sendRdi(34)  

prtGenTestDuration 1.3.6.1.4.1.164.3.3.3.1.2.1.3
This attribute indicates the maximum duration of executing a test on the specific port. This entry applies to the specified test . The resolution will be a minute, and the maximum duration is limited to 30 minutes . A zero value specifies no time limitation. When the test isn't active the agent initiates this object to 2 min. when the duration is needed and to 0 if it's not required.
OBJECT-TYPE    
  Integer32  

prtGenTsTable 1.3.6.1.4.1.164.3.3.3.1.3
The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch),exept some products which enable direct writing to the ActiveCnfg. This is written in the respective product's spec.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenTsEntry

prtGenTsEntry 1.3.6.1.4.1.164.3.3.3.1.3.1
An entry in table.
OBJECT-TYPE    
  PrtGenTsEntry  

prtGenTsCnfgIdx 1.3.6.1.4.1.164.3.3.3.1.3.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtGenTsPrtIdx 1.3.6.1.4.1.164.3.3.3.1.3.1.2
This attribute indicates a unique port number. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
OBJECT-TYPE    
  Integer32  

prtGenTsIdx 1.3.6.1.4.1.164.3.3.3.1.3.1.3
This attribute indicates a unique time slot position. The valid time slots are 1..25 for T1 Card (25=Fbit) 0..31 for E1 or HS Card . In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
OBJECT-TYPE    
  Integer32  

prtGenTsType 1.3.6.1.4.1.164.3.3.3.1.3.1.4
The type of Timeslot. If the source or destination port is an HS port,'TS Type' must be 'data'. nc - means that this TimeSlot is not connected. voice, data, vcMP - also mean that this TS is connected. mng - means that this TS is dedicated to Management (not connected to another port.
OBJECT-TYPE    
  INTEGER unknown(1), voice(2), data(3), vcMP(4), nc(5), mng(6)  

prtGenTsIConPrt 1.3.6.1.4.1.164.3.3.3.1.3.1.5
This attribute indicates the internally (In Mux) connected port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside ports will be for example, the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * noConnection - will be indicated as 10 for DXC and FCD-E1/T1. - will be indicated as 100 for FCD-E1/I and SMODs. * Split TS (same TS is Split to several ports) - 11. * notApplicable- will be indicated as 100 for LRS IMODs. All HS port's timeslots must have the same destination port.
OBJECT-TYPE    
  Integer32  

prtGenTsIConTs 1.3.6.1.4.1.164.3.3.3.1.3.1.6
This attribute indicates a unique time slot position. The valid time slots are 1..25 for T1 Card (25=Fbit) 0..31 for E1 (or HS) Card. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling. * For DXC: All HS port's timeslots must start with Timeslot no.1
OBJECT-TYPE    
  Integer32  

prtAlr 1.3.6.1.4.1.164.3.3.3.1.4
OBJECT IDENTIFIER    

prtSAlarmTable 1.3.6.1.4.1.164.3.3.3.1.4.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSAlarmEntry

prtSAlarmEntry 1.3.6.1.4.1.164.3.3.3.1.4.1.1
An entry in table.
OBJECT-TYPE    
  PrtSAlarmEntry  

prtSAlarmIdx 1.3.6.1.4.1.164.3.3.3.1.4.1.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive.
OBJECT-TYPE    
  Integer32  

prtSAlarmPrtIdx 1.3.6.1.4.1.164.3.3.3.1.4.1.1.2
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
OBJECT-TYPE    
  Integer32  

prtSAlarmCode 1.3.6.1.4.1.164.3.3.3.1.4.1.1.3
This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
OBJECT-TYPE    
  Integer32  

prtSAlarmState 1.3.6.1.4.1.164.3.3.3.1.4.1.1.4
This object indicates the port alarm severity.
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

prtSAlarmMask 1.3.6.1.4.1.164.3.3.3.1.4.1.1.5
Alarm Mask is : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlarmInvert 1.3.6.1.4.1.164.3.3.3.1.4.1.1.6
Alarm Invert is : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlarmOnOff 1.3.6.1.4.1.164.3.3.3.1.4.1.1.7
Alarm state is : on/off.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlarmCounter 1.3.6.1.4.1.164.3.3.3.1.4.1.1.8
A counter - how many times the alarm occured (ON) since last clear operation or since last Reset.
OBJECT-TYPE    
  Integer32  

prtAlrMaskTable 1.3.6.1.4.1.164.3.3.3.1.4.2
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAlrMaskEntry

prtAlrMaskEntry 1.3.6.1.4.1.164.3.3.3.1.4.2.1
An entry in table.
OBJECT-TYPE    
  PrtAlrMaskEntry  

prtAlrMaskPrtIdx 1.3.6.1.4.1.164.3.3.3.1.4.2.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
OBJECT-TYPE    
  Integer32  

prtAlrMask 1.3.6.1.4.1.164.3.3.3.1.4.2.1.2
This object is a mask that indicates which port level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the port level will be 0. This object is applicable only when prtGenAlrMaskAll=off (otherwise all port alarms are masked). Example: When Alarms having the codes 31 and 40 are masked, the value of this object will be 10080000000 (hex).
OBJECT-TYPE    
  OCTET STRING SIZE(8)  

prtBertTable 1.3.6.1.4.1.164.3.3.3.1.5
This table includes the BERT parameters, counters and commands. The configurable parameters: - prtBertPattern - prtBertInjectRate - prtBertTs are not Set per configuration (same for all Configurations) but start being applied by the Agent only upon successful Update/Download operation. Therefore, Set will enter the values to the Temporary Configuration of the agent, while Get will get the values of the Active Configuration.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtBertEntry

prtBertEntry 1.3.6.1.4.1.164.3.3.3.1.5.1
An entry in table.
OBJECT-TYPE    
  PrtBertEntry  

prtBertPrtIdx 1.3.6.1.4.1.164.3.3.3.1.5.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . In the MP : - first two digits will be: (IO slot number+10) - last one/two digits will be according to the external port number within the card: exPrt1 -> 1 exPrt2 -> 3 exPrt3 -> 5 exPrt4 -> 7 .
OBJECT-TYPE    
  Integer32  

prtBertPattern 1.3.6.1.4.1.164.3.3.3.1.5.1.2
This object indicates the pattern of the BERT. p2Exxm1 = 2Exx-1. pxx = pattern xx. This object is the same for all configurations. notApplicable - when this object is not supported.
OBJECT-TYPE    
  INTEGER p2E3m1(1), p2E4m1(2), p2E5m1(3), p2E6m1(4), p2E7m1(5), p511(6), p2E10m1(7), p2047(8), p2E15m1(9), p2E17m1(10), p2E18m1(11), p2E20m1(12), qrss(13), p2E21m1(14), p2E22m1(15), p2E23m1(16), p2E25m1(17), p2E28m1(18), p2E29m1(19), p2E31m1(20), p2E32m1(21), rj011(22), p63(23), p1M7S(24), p1S7M(25), alternate(26), mark(27), space(28), notApplicable(255)  

prtBertInjectRate 1.3.6.1.4.1.164.3.3.3.1.5.1.3
This object indicates the error rate injection of the BERT. r10Emx = 10E-x This object is the same for all configurations. single - single error injection. notApplicable - when this object is not supported.
OBJECT-TYPE    
  INTEGER noError(1), r10Em1(2), r10Em2(3), r10Em3(4), r10Em4(5), r10Em5(6), r10Em6(7), r10Em7(8), single(9), notApplicable(255)  

prtBertInjectErrRateCmd 1.3.6.1.4.1.164.3.3.3.1.5.1.4
This object controls activation/deactivation of the Error Rate Injection during BERT.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtBertInjectSingleErrCmd 1.3.6.1.4.1.164.3.3.3.1.5.1.5
This object enables to initiate a Single Error Injection during BERT (on). Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtBertRunTime 1.3.6.1.4.1.164.3.3.3.1.5.1.6
This object indicates how much time (seconds) passed since BERT started to run.
OBJECT-TYPE    
  Integer32  

prtBertESs 1.3.6.1.4.1.164.3.3.3.1.5.1.7
How many Errored Seconds were detected since BERT started to run. Counter for Kmux and MP.
OBJECT-TYPE    
  Integer32  

prtBertSyncLoss 1.3.6.1.4.1.164.3.3.3.1.5.1.8
How many times Sync Loss was detected since BERT started to run. For some products: number of seconds in which Sync Loss occured since BERT started to run. See product specification.
OBJECT-TYPE    
  Integer32  

prtBertErrorBits 1.3.6.1.4.1.164.3.3.3.1.5.1.9
How many Error Bits were detected since BERT started to run.
OBJECT-TYPE    
  Integer32  

prtBertClearCounters 1.3.6.1.4.1.164.3.3.3.1.5.1.10
Setting this object to ON, will enforce a clear operation of some BERT Counters. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtBertSyncStatus 1.3.6.1.4.1.164.3.3.3.1.5.1.11
Sync Status while BERT runs.
OBJECT-TYPE    
  INTEGER notApplicable(1), syncLoss(2), sync(3)  

prtBertTs 1.3.6.1.4.1.164.3.3.3.1.5.1.12
This object indicates on which TSs of the selected port, BERT should be applied. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - BERT should be applied on this TS. For a T1 port, the valid raised bits ('1') are: 1..25. For an E1 port, the valid raised bits ('1') are: 1..31. Agents that do not support this feature will send SIZE 0.
OBJECT-TYPE    
  OCTET STRING SIZE(0..4)  

prtBertResult 1.3.6.1.4.1.164.3.3.3.1.5.1.13
This object indicates Result of BERT for the selected port (number of error bits divided to the total number of data bits.) Applicable only if BERT is running on this port Agents that do not support this feature will send SIZE 0.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

prtMonTable 1.3.6.1.4.1.164.3.3.3.1.6
For DXC, the write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch).
OBJECT-TYPE    
  SEQUENCE OF  
    PrtMonEntry

prtMonEntry 1.3.6.1.4.1.164.3.3.3.1.6.1
An entry in table.
OBJECT-TYPE    
  PrtMonEntry  

prtMonCnfgIdx 1.3.6.1.4.1.164.3.3.3.1.6.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg. For products that do not support configurations, 1 will be always used.
OBJECT-TYPE    
  Integer32 1..255  

prtMonitoringIdx 1.3.6.1.4.1.164.3.3.3.1.6.1.2
This object indicates the Monitoring Port Index. For DXC: The valid port number depends on the IO slot no., the installed card type and the port type: external, internal. * The external ports will according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The internal ports will be according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For Optimux-T3: 255 (Not Applicable) will be always used. The Monitoring port is always the Station Clock (not considered an interface).
OBJECT-TYPE    
  Integer32  

prtMonitoringEnable 1.3.6.1.4.1.164.3.3.3.1.6.1.3
This object indicates if the prtMonitoringIdx is configured as a monitoring port or not. disabled = the port is NOT configured to monitor. Setting this object to this value will cause reset (to 0) of the prtMonitoringTSs and prtMonitoredTSs objects. enabled = the port IS configured to monitor. For Optimux-T3: always enabled (RO supported).
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtMonitoringTSs 1.3.6.1.4.1.164.3.3.3.1.6.1.4
This object indicates which TSs of the Monitoring port, the test equipment should monitor. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - this TS should be monitored. For a T1 port, the valid raised bits ('1') are: 1..24. For an E1 port, the valid raised bits ('1') are: 1..31. Default: all bits='0' Agents that do not support this feature will send SIZE 0. This object can be Set as described only if prtMonitoringEnable=enabled.
OBJECT-TYPE    
  OCTET STRING SIZE(0..4)  

prtMonitoredPort 1.3.6.1.4.1.164.3.3.3.1.6.1.5
This object indicates the MONITORED Port Index that the Monitoring port monitors. For DXC: The valid port number depends on the IO slot no., the installed card type and the port type: external, internal. * The external ports will according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The internal ports will be according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * 100 - no port monitored For Optimux-T3: The valid channels are: 0 = no Ch monitored 1..21 or 1..28 (=CH1..CH21 or CH1..CH28) according to product's configuration.
OBJECT-TYPE    
  Integer32  

prtMonitoredTSs 1.3.6.1.4.1.164.3.3.3.1.6.1.6
This object indicates which TSs of the Monitored port, should be monitored. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - this TS should be monitored. For a T1 port, the valid raised bits ('1') are: 1..24. For an E1 port, the valid raised bits ('1') are: 1..31. Default: all bits='0' Agents that do not support this feature will send SIZE 0. This object can be Set as described only if prtMonitoringEnable=enabled.
OBJECT-TYPE    
  OCTET STRING SIZE(0..4)  

prtCfgParam 1.3.6.1.4.1.164.3.3.3.1.7
OBJECT IDENTIFIER    

prtCfgParamTable 1.3.6.1.4.1.164.3.3.3.1.7.1
The write operation into the Table Objects is valid only to the TmpCnfg entry. Parameters for the channels of the KMUX Cards: KMBE/New, KVF.6 family.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCfgParamEntry

prtCfgParamEntry 1.3.6.1.4.1.164.3.3.3.1.7.1.1
An entry in table.
OBJECT-TYPE    
  PrtCfgParamEntry  

prtCfgParamCnfgIdx 1.3.6.1.4.1.164.3.3.3.1.7.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtCfgParamIdx 1.3.6.1.4.1.164.3.3.3.1.7.1.1.2
A unique identifier of the port (within the card when applicable). - For KM-2100: Slot*100+Ch external ports: Ch=1..10 internal ports (sub-channels): Ch=11..20. - For FCD-T1/E1: SUB=113, CH1=122, CH2=124.
OBJECT-TYPE    
  Integer32  

prtCfgParamSlt 1.3.6.1.4.1.164.3.3.3.1.7.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid. notApplicable(255) - for products that do not have Slots.
OBJECT-TYPE    
  INTEGER kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable(255)  

prtCfgParamOperatedMl 1.3.6.1.4.1.164.3.3.3.1.7.1.1.4
The main link for this channel. The field is relevant only for ML modes of Dual, Priority Bumping and Switched Backup.
OBJECT-TYPE    
  INTEGER notApplicable(1), kmxMlA(103), kmxMlB(104)  

prtCfgParamMlAtoMlBPrio 1.3.6.1.4.1.164.3.3.3.1.7.1.1.5
ML-A to ML-B Priority. The field is relevant only for ML modes of Priority Bumping and Switched Backup.
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

prtCfgParamMlBtoMlAPrio 1.3.6.1.4.1.164.3.3.3.1.7.1.1.6
ML-B to ML-A Priority. The field is relevant only for ML modes of Priority Bumping.
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

prtCfgParamInbandLoopDetection 1.3.6.1.4.1.164.3.3.3.1.7.1.1.7
Inband Loop Detection. The field is relevant for the following FCD-T1/E1 ports: SUB, CH1, CH2.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtT1E1 1.3.6.1.4.1.164.3.3.3.2
OBJECT IDENTIFIER    

prtT1E1StatTable 1.3.6.1.4.1.164.3.3.3.2.1
T1/E1 port statistics table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1E1StatEntry

prtT1E1StatEntry 1.3.6.1.4.1.164.3.3.3.2.1.1
An entry in the T1/E1 port statistics table.
OBJECT-TYPE    
  PrtT1E1StatEntry  

prtT1E1SPrtIdx 1.3.6.1.4.1.164.3.3.3.2.1.1.1
This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 .
OBJECT-TYPE    
  Integer32  

prtT1E1SSlt 1.3.6.1.4.1.164.3.3.3.2.1.1.2
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtT1E1OosCount 1.3.6.1.4.1.164.3.3.3.2.1.1.3
This object is applicable only for an E1 active port. It provides the number of red alarm events since the last count clearing.
OBJECT-TYPE    
  Gauge32  

prtT1E1BpvLastMin 1.3.6.1.4.1.164.3.3.3.2.1.1.4
This object is applicable only for an E1 active port. It provides the number of BPV (BiPolar Violation) events detected during the last minute.
OBJECT-TYPE    
  Gauge32  

prtT1E1BpvMax 1.3.6.1.4.1.164.3.3.3.2.1.1.5
This object is applicable only for an E1 active port. It provides the maximal number of BPV (BiPolar Violation) events (per minute), detected during the worst minute.
OBJECT-TYPE    
  Gauge32  

prtT1E1CnfgTable 1.3.6.1.4.1.164.3.3.3.2.2
T1/E1 port configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1E1CnfgEntry

prtT1E1CnfgEntry 1.3.6.1.4.1.164.3.3.3.2.2.1
An entry in the T1/E1 port configuration table.
OBJECT-TYPE    
  PrtT1E1CnfgEntry  

prtT1E1CnfgIdx 1.3.6.1.4.1.164.3.3.3.2.2.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
OBJECT-TYPE    
  Integer32 1..255  

prtT1E1PrtIdx 1.3.6.1.4.1.164.3.3.3.2.2.1.2
This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20.
OBJECT-TYPE    
  Integer32  

prtT1E1Slt 1.3.6.1.4.1.164.3.3.3.2.2.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxMlA(103), kmxMlB(104), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), standAlone(255)  

prtT1E1LineType 1.3.6.1.4.1.164.3.3.3.2.2.1.4
This variable indicates the variety of T1/E1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: esf Extended SuperFrame DS1 d4 AT&T D4 format DS1 - SF e1 CCITT Recommendation G.704 (Table 4a) - G732N e1Crc CCITT Recommendation G.704 (Table 4b) - G732N with CRC e1MF G.704 (Table 4a) with TS16 multiframing enabled - G732S e1CrcMF G.704 (Table 4b) with TS16 multiframing enabled - G732S with CRC unframed T1 - applicable values: (1),(2),(3),(8) E1 - applicable values: (1),(4),(5),(6),(7),(8)
OBJECT-TYPE    
  INTEGER other(1), esf(2), d4(3), e1(4), e1Crc(5), e1MF(6), e1CrcMF(7), unframed(8)  

prtT1E1LineCode 1.3.6.1.4.1.164.3.3.3.2.2.1.5
This variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteristics. jbzs=b7zs refers the Jammed Bit Zero Suppres- sion, in which the AT&T specification of at least one pulse every 8 bit periods is literal- ly implemented by forcing a pulse in bit 8 of each channel. Thus, only seven bits per chan- nel, or 1.344 Mbps, is available for data (used for T1). b8zs refers to the use of a specified pattern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits (used for T1). ANSI Clear Channels may use zbtsi, or Zero Byte Time Slot Interchange. E1 links, with or without CRC, use hdb3 or ami (= TRAN). amI (=TRAN) refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density re- quirements, such as inverting HDLC data.
OBJECT-TYPE    
  INTEGER jbzs(1), b8zs(2), hdb3(3), zbtsi(4), ami(5), other(6)  

prtT1E1SignalMode 1.3.6.1.4.1.164.3.3.3.2.2.1.6
'none' indicates that no bits are reserved for signaling on this channel. 'robbedBit' indicates that T1 Robbed Bit Signaling is in use. 'bitOriented' indicates that E1 Channel Associated Signaling (CAS) is in use. 'messageOriented' indicates that Common Channel Signaling (CCS) is in use either on channel 16 of an E1 link or channel 24 of a T1.
OBJECT-TYPE    
  INTEGER none(1), robbedBit(2), bitOriented(3), messageOriented(4)  

prtT1E1Fdl 1.3.6.1.4.1.164.3.3.3.2.2.1.7
This bitmap describes the use of the facili- ties data link, and is the sum of the capabili- ties: 'other' indicates that a protocol other than one following is used. 'ansi-T1-403' refers to the FDL exchange recommended by ANSI. 'att-54016' refers to ESF FDL exchanges. 'fdl-none' indicates that the device does not use the FDL. 'transFdl' indicates transition between two ports of the same card.
OBJECT-TYPE    
  INTEGER other(1), ansi-T1-403(2), att-54016(4), fdl-none(8), transFdl(16)  

prtT1E1FdlMode 1.3.6.1.4.1.164.3.3.3.2.2.1.8
Fdl Mode of the T1 selected port. notApplicable - will be used for an E1 port.
OBJECT-TYPE    
  INTEGER other(1), user(2), carrier(3), notApplicable(255)  

prtT1E1Sync 1.3.6.1.4.1.164.3.3.3.2.2.1.9
This object enables returning to normal operation, after the end of a main/sub link red alarm event, in reduced time. 'tr62411' - complies with AT&T TR-62411 (after 10 seconds). Applicable for both T1 and E1 interfaces. 'ccitt' - complies with CCITT standard. Applicable only for E1 interfaces. 'fast' - after 1 second.
OBJECT-TYPE    
  INTEGER other(1), tr62411(2), ccitt(3), fast(4)  

prtT1E1CGA 1.3.6.1.4.1.164.3.3.3.2.2.1.10
This object selects the method used to signal the CGA state to the other end, through the main/sub link. 'none' - non-transparent mode. When one of the links (main/sub) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos Signal' will be transmitted to the other end. 'trans' - when one of the links (main/sub) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main/sub) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos Signal' will be transmitted to the other end.
OBJECT-TYPE    
  INTEGER none(1), trans(2), full(3)  

prtT1E1IdleCode 1.3.6.1.4.1.164.3.3.3.2.2.1.11
This object selects the code transmitted to fill idle (unused) time slots in the main link frame. Valid range: (0 - FF HEX) .
OBJECT-TYPE    
  OCTET STRING SIZE(0..4)  

prtT1E1OosSignal 1.3.6.1.4.1.164.3.3.3.2.2.1.12
'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0
OBJECT-TYPE    
  INTEGER notsupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtT1E1VoiceOos 1.3.6.1.4.1.164.3.3.3.2.2.1.13
Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
OBJECT-TYPE    
  OCTET STRING SIZE(0..4)  

prtT1E1DataOos 1.3.6.1.4.1.164.3.3.3.2.2.1.14
Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
OBJECT-TYPE    
  OCTET STRING SIZE(0..4)  

prtT1E1LineLengthMask 1.3.6.1.4.1.164.3.3.3.2.2.1.15
This attribute is the line length mask parameter used only for T1/DSU interfaces. len400p533ft=length range: 400ft to 533ft 'fcc68' - provides compliance with the FCC 68.308 Option A output pulse mask.
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), fcc68(7)  

prtT1E1TxGainMask 1.3.6.1.4.1.164.3.3.3.2.2.1.16
This attribute is the tx gain mask parameter (dB), used only for T1/CSU interfaces.
OBJECT-TYPE    
  INTEGER notApplicable(1), txGain0db(2), txGain7dot5db(3), txGain15db(4), txGain22dot5db(5)  

prtT1E1InbandMng 1.3.6.1.4.1.164.3.3.3.2.2.1.17
A unique number to identify an Inband management over the link. internal - supported by KM-2100 only. It means that the management is internal to the frame. It takes part of the ML Frame bits (instead of data).
OBJECT-TYPE    
  INTEGER off(2), fdlOrTs0(3), dedicatedTs(4), dedicatedPpp(5), dedicatedFr(6), internal(7)  

prtT1E1InbandMngRate 1.3.6.1.4.1.164.3.3.3.2.2.1.18
A unique number to identify the rate of the Inband management. It is required only for E1 links and is applicable only when prtExT1E1InbandMng selected is FdlOrTs0 or dedicatedTs.
OBJECT-TYPE    
  INTEGER notApplicable(1), r4k(2), r8k(3), r12k(4), r16k(5), r32k(6), r64k(7), r20k(8)  

prtT1E1DedicatedTs 1.3.6.1.4.1.164.3.3.3.2.2.1.19
The value is differently determined for different products. There are two methods: 1) A unique number to identify Dedicated TS of the T1/E1 port. It is applicable only when prtExT1E1InbandMng selected is dedicatedTs. 1..24 - Dedicated TS of T1 1..31 - Dedicated TS of E1 255 - notApplicable (for agents that do not support this feature) Other values are invalid. 2) For FCD-STM, up to five TSs may be dedicated to management. This object value is the Sum (sigma) of 2**n, where n =TS-1 e.g. Time slots 3,5,7,9,11 are dedicated to management: 2** 2 +2** 4 +2** 6 +2** 8 +2**10 = 4+16+64+256+1024=1364 User should consult the product specification, to find out the method employed.
OBJECT-TYPE    
  Integer32  

prtT1E1InbandMngRoutProt 1.3.6.1.4.1.164.3.3.3.2.2.1.20
Inband Mng Routing Protocol of the port. When prtT1E1InbandMng is 'dedicatedPpp'-'proprietary' and 'rip2' are applicable. For other values - only 'proprietary' is applicable. For FCD-M and FCD-A: When prtT1E1InbandMng is 'dedicatedPpp' or 'dedicatedFr': 'None', 'proprietary' and 'rip2' are applicable. When prtT1E1InbandMng is 'fdlOrTS0' or 'dedicatedTs': 'None' and 'proprietary' are applicable. When prtT1E1InbandMng is 'off': 'None' is applicable.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtT1E1LinkMode 1.3.6.1.4.1.164.3.3.3.2.2.1.21
regular - TSs are connected by user via TS Assignment only transparent - when a port with this Link Mode is connected to an internal T1/E1 port of a T3/E3 card, TS0, TS16 and Fbit are transparently transferred to the E3/T3 stream.
OBJECT-TYPE    
  INTEGER notApplicable(1), regular(2), transparent(3)  

prtT1E1Multiplier 1.3.6.1.4.1.164.3.3.3.2.2.1.22
The data rate of each TS. The multiplier values can be 56 kbps or 64 kbps. For T1 only.
OBJECT-TYPE    
  INTEGER notApplicable(1), br56(2), br64(3)  

prtT1E1RxGain 1.3.6.1.4.1.164.3.3.3.2.2.1.23
This attribute is the rx volume (dB).
OBJECT-TYPE    
  INTEGER notApplicable(1), rxGain12dB(2), rxGain30dB(3), rxGain36dB(4), shortHaul(5), longHaul(6)  

prtT1E1RAI 1.3.6.1.4.1.164.3.3.3.2.2.1.24
Remote Alarm Signal
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtT1E1LineMode 1.3.6.1.4.1.164.3.3.3.2.2.1.25
Interface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values
OBJECT-TYPE    
  INTEGER notApplicable(1), csu(2), dsu(3), ltu(4)  

prtT1E1TS0SaBits 1.3.6.1.4.1.164.3.3.3.2.2.1.26
This object is applicable only for E1 ports. For T1, string size will be 0. For E1, it enables user to select the use of TS0 Sa Bits 4..8, by 3 octets: The order (in hexa display): free Sa-Bit-4 Sa-Bit-5 Sa-Bit-6 Sa-Bit-7 Sa-Bit-8 |___________| |________________| |________________| MSByte LSByte Each Sa Bit will be represented by a nibble, having the following meaning: 0000 = zero 0001 = one 0010 = management 0011 = transparent the rest are reserved for future use.
OBJECT-TYPE    
  OCTET STRING  

prtT1E1ConnectedTS 1.3.6.1.4.1.164.3.3.3.2.2.1.27
This parameter indicates if there is any connected TS for this interface.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtT1E1Ts0SaBit 1.3.6.1.4.1.164.3.3.3.2.2.1.28
This parameter indicates whether to send TS 0, or not. noMng= TS 0 is looped, therefore not sent. mng= TS 0 isn't looped, therefore it is sent.
OBJECT-TYPE    
  INTEGER notApplicable(1), noMng(2), mng(3)  

prtT1E1SameFeCnfg 1.3.6.1.4.1.164.3.3.3.2.2.1.29
This parameter indicates whether the same E1 configuration parameters and TS assignment are set both to the local and remote device. Read-Write access is applicable only in G732N framed mode. For G732S and UNFRAMED this parameter is set by agent to YES and is Read Only. In Case of conflict during power-up between the central and remote, the value set by the central unit is the valid one.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtT1E1RemCrc4 1.3.6.1.4.1.164.3.3.3.2.2.1.30
This object indicates whether the E1 of the Remote device connected to this E1 port, will have CRC-4 or not.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtT1E1MaxTSs 1.3.6.1.4.1.164.3.3.3.2.2.1.31
This object is applicable only for DXC D4T1, D4E1, D8T1, D8E1 external ports and D8GSL internal E1 ports. It is relevant only when sysCIntTsAllocMode=static(2). 255=not applicable If prtT1E1LineType=unframed(8), the value of this object must be 32. Else, the valid values are 0..31.
OBJECT-TYPE    
  Integer32  

prtT1E1EocTsConfig 1.3.6.1.4.1.164.3.3.3.2.2.1.32
This object indicates whether the use of EOC for TS Configuration is enabled or not.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtT1E1FdlMsgTable 1.3.6.1.4.1.164.3.3.3.2.3
This table is applicable for a T1 interface with 'esf' LineType or E1 interface, when CRC is enabled (LineType).
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1E1FdlMsgEntry

prtT1E1FdlMsgEntry 1.3.6.1.4.1.164.3.3.3.2.3.1
An entry in table.
OBJECT-TYPE    
  PrtT1E1FdlMsgEntry  

prtT1E1FdlMsgPrtIdx 1.3.6.1.4.1.164.3.3.3.2.3.1.1
This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 .
OBJECT-TYPE    
  Integer32  

prtT1E1FdlMsgFdlType 1.3.6.1.4.1.164.3.3.3.2.3.1.2
The Fdl type reference of the Fdl message.
OBJECT-TYPE    
  INTEGER send(1), receive(2)  

prtT1E1FdlMsgSlt 1.3.6.1.4.1.164.3.3.3.2.3.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtT1E1FdlMsg 1.3.6.1.4.1.164.3.3.3.2.3.1.4
FDL message.
OBJECT-TYPE    
  OCTET STRING  

prtHS 1.3.6.1.4.1.164.3.3.3.3
OBJECT IDENTIFIER    

prtHSParamTable 1.3.6.1.4.1.164.3.3.3.3.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHSParamEntry

prtHSParamEntry 1.3.6.1.4.1.164.3.3.3.3.1.1
An entry in table.
OBJECT-TYPE    
  PrtHSParamEntry  

prtHSCnfgIdx 1.3.6.1.4.1.164.3.3.3.3.1.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
OBJECT-TYPE    
  Integer32 1..255  

prtHSPrtIdx 1.3.6.1.4.1.164.3.3.3.3.1.1.2
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
OBJECT-TYPE    
  Integer32  

prtHSSlt 1.3.6.1.4.1.164.3.3.3.3.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtHSRate 1.3.6.1.4.1.164.3.3.3.3.1.1.4
This object indicates the port rate (speed). auto - rate is selected automatically by system.
OBJECT-TYPE    
  INTEGER r0x56eq0Kbps(1), r1x56eq56Kbps(2), r2x56eq112Kbps(3), r3x56eq168Kbps(4), r4x56eq224Kbps(5), r5x56eq280Kbps(6), r6x56eq336Kbps(7), r7x56eq392Kbps(8), r8x56eq448Kbps(9), r9x56eq504Kbps(10), r10x56eq560Kbps(11), r11x56eq616Kbps(12), r12x56eq672Kbps(13), r13x56eq728Kbps(14), r14x56eq784Kbps(15), r15x56eq840Kbps(16), r16x56eq896Kbps(17), r17x56eq952Kbps(18), r18x56eq1008Kbps(19), r19x56eq1064Kbps(20), r20x56eq1120Kbps(21), r21x56eq1176Kbps(22), r22x56eq1232Kbps(23), r23x56eq1288Kbps(24), r24x56eq1344Kbps(25), r25x56eq1400Kbps(26), r26x56eq1456Kbps(27), r27x56eq1512Kbps(28), r28x56eq1568Kbps(29), r29x56eq1624Kbps(30), r30x56eq1680Kbps(31), r31x56eq1736Kbps(32), r0x64eq0Kbps(33), r1x64eq64Kbps(34), r2x64eq128Kbps(35), r3x64eq192Kbps(36), r4x64eq256Kbps(37), r5x64eq320Kbps(38), r6x64eq384Kbps(39), r7x64eq448Kbps(40), r8x64eq512Kbps(41), r9x64eq576Kbps(42), r10x64eq640Kbps(43), r11x64eq704Kbps(44), r12x64eq768Kbps(45), r13x64eq832Kbps(46), r14x64eq896Kbps(47), r15x64eq960Kbps(48), r16x64eq1024Kbps(49), r17x64eq1088Kbps(50), r18x64eq1152Kbps(51), r19x64eq1216Kbps(52), r20x64eq1280Kbps(53), r21x64eq1344Kbps(54), r22x64eq1408Kbps(55), r23x64eq1472Kbps(56), r24x64eq1536Kbps(57), r25x64eq1600Kbps(58), r26x64eq1664Kbps(59), r27x64eq1728Kbps(60), r28x64eq1792Kbps(61), r29x64eq1856Kbps(62), r30x64eq1920Kbps(63), r31x64eq1984Kbps(64), r32x64eq2048Kbps(65), r32x56eq1792Kbps(66), r64x64eq4096Kbps(67), auto(200)  

prtHSFifoSize 1.3.6.1.4.1.164.3.3.3.3.1.1.5
This object selects the size of the user data channel buffer FIFO used in the DTE2 mode. In the other modes, buffer size is automatically set by the DACS agent. Buffer FIFO size in bits, corresponds to FIFO lengths of +/-16, +/-30, +/-52, +/-72 bits.
OBJECT-TYPE    
  INTEGER auto(1), b32bit(2), b60bit(3), b104bit(4), b144bit(5), notApplicable(255)  

prtHSClkMode 1.3.6.1.4.1.164.3.3.3.3.1.1.6
Clock Mode of the user data channel. dce - DACS operates as a DCE and provides transmit and receive clocks to the synchronous user DTE. dte1- DACS supplies the receive clock to the user equipment and accepts the user transmit clock. dte2- DACS requires transmit and receive clocks from the user equipment.
OBJECT-TYPE    
  INTEGER dce(1), dte1(2), dte2(3), notApplicable(255)  

prtHSCTS 1.3.6.1.4.1.164.3.3.3.3.1.1.7
Selection of CTS line state in the user data channel. on - CTS continuously ON. rts - CTS line follows the RTS line.
OBJECT-TYPE    
  INTEGER on(1), rts(2), notApplicable(255)  

prtHSRtsState 1.3.6.1.4.1.164.3.3.3.3.1.1.8
RTS state of the port.
OBJECT-TYPE    
  INTEGER off(2), on(3), notApplicable(255)  

prtHSInbandLoopback 1.3.6.1.4.1.164.3.3.3.3.1.1.9
This object indicates if Inband Loopback from the Network should be enabled or disabled.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtHSInbandLoopPatternCfg 1.3.6.1.4.1.164.3.3.3.3.1.1.10
This object indicates if Inband Loop polynomial pattern will be according to RDL Loop (the standard) or User Configurated according to prtHSActivatePolyPattern and prtHSDeactivatePolyPattern.
OBJECT-TYPE    
  INTEGER notApplicable(1), rdlLoop(2), userConfig(3)  

prtHSInbandLoopActPattern 1.3.6.1.4.1.164.3.3.3.3.1.1.11
This object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Activate the Inband Loop. This object is relevant only when prtHSInbandLoopPatternCfg=userConfig.
OBJECT-TYPE    
  DisplayString  

prtHSInbandLoopDeactPattern 1.3.6.1.4.1.164.3.3.3.3.1.1.12
This object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Deactivate the Inband Loop. This object is relevant only when prtHSInbandLoopPatternCfg=userConfig.
OBJECT-TYPE    
  DisplayString  

prtHSDCD 1.3.6.1.4.1.164.3.3.3.3.1.1.13
Selection of DCD line state in the user data channel. linkOK - DCD line is ON only when active link is OK. on - DCD continuously ON.
OBJECT-TYPE    
  INTEGER notApplicable(1), linkOK(2), on(3)  

prtHSBertTable 1.3.6.1.4.1.164.3.3.3.3.2
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHSBertEntry

prtHSBertEntry 1.3.6.1.4.1.164.3.3.3.3.2.1
An entry in table.
OBJECT-TYPE    
  PrtHSBertEntry  

prtHSBertPrtIdx 1.3.6.1.4.1.164.3.3.3.3.2.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
OBJECT-TYPE    
  Integer32  

prtHSBertSlt 1.3.6.1.4.1.164.3.3.3.3.2.1.2
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtHSBertCountClr 1.3.6.1.4.1.164.3.3.3.3.2.1.3
Setting this object (to on) initiate bert counter clear operation. Valid only when bert test is active on the specific port. (Every time a new bert test starts, the counter is automatically cleared; this command enables clearing the counter while the test is running).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtHSBertTestResult 1.3.6.1.4.1.164.3.3.3.3.2.1.4
This object indicates the number of Bit Error Rate indicated during the BERT test. Active only when bert test is running on the selected port.
OBJECT-TYPE    
  Integer32  

prtSP 1.3.6.1.4.1.164.3.3.3.4
OBJECT IDENTIFIER    

prtSpCnfgTable 1.3.6.1.4.1.164.3.3.3.4.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSpCnfgEntry

prtSpCnfgEntry 1.3.6.1.4.1.164.3.3.3.4.1.1
All the entries at this table are identical(have the same value) at all the configurations(1..255) except at the TmpCnfg. - For products supporting more than one configuration, the write operation into the Table Objects is valid only at the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table Objects will be to prtSpCnfgIdx=1.
OBJECT-TYPE    
  PrtSpCnfgEntry  

prtSpCnfgIdx 1.3.6.1.4.1.164.3.3.3.4.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtSpPrtIdx 1.3.6.1.4.1.164.3.3.3.4.1.1.2
This attribute indicates a unique port number of the SPor DP port. For DXC, it is the port in the active DCL card: - SP = 1 - NP ; DP = 2 For Kilomux, the port index is calculated as follows: 100*Slot+Ch. For FCD, PRBi, the SP port index=1. For Optimux-T3, the SP port index=71.
OBJECT-TYPE    
  Integer32  

prtSpUsage 1.3.6.1.4.1.164.3.3.3.4.1.1.3
This attribute indicates what is the usage of the port.
OBJECT-TYPE    
  INTEGER unknown(1), noUse(2), nmsSlip(3), nmsPpp(4), muxSlip(5), muxPpp(6), terminal(7), dialOut(8)  

prtSpRate 1.3.6.1.4.1.164.3.3.3.4.1.1.4
This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent.
OBJECT-TYPE    
  INTEGER auto(1), s300bps(2), s1200bps(3), s2400bps(4), s4800bps(5), s9600bps(6), s19200bps(7), s38400bps(8), s57600bps(9), s115200bps(10)  

prtSpDataBits 1.3.6.1.4.1.164.3.3.3.4.1.1.5
This attribute indicates the number of data bits in async frame
OBJECT-TYPE    
  INTEGER dataBits7(1), dataBits8(2)  

prtSpParity 1.3.6.1.4.1.164.3.3.3.4.1.1.6
This attribute indicates the parity mode in async frame
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3)  

prtSpCallOutMode 1.3.6.1.4.1.164.3.3.3.4.1.1.7
This attribute indicates the call-out mode. For DXC - this object is applicable only for the DP port (2).
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), all(3), major(4)  

prtSpInterface 1.3.6.1.4.1.164.3.3.3.4.1.1.8
This attribute indicates the supervisory port interface. dce - the DACS appears as a DCE for the port. dte - the DACS operates as a DTE, for connection via modem, for the port.
OBJECT-TYPE    
  INTEGER dce(1), dte(2)  

prtSpCTS 1.3.6.1.4.1.164.3.3.3.4.1.1.9
CTS line state. This object is applicable only for port (1) = SP
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3)  

prtSpDcdDelay 1.3.6.1.4.1.164.3.3.3.4.1.1.10
DCD delay in msec. d10 = delay of 10msec. This object is applicable only for port (1) = SP
OBJECT-TYPE    
  INTEGER notApplicable(1), d0(2), d10(3), d50(4), d100(5), d200(6), d300(7)  

prtSpDsr 1.3.6.1.4.1.164.3.3.3.4.1.1.11
DSR line state. This object is applicable only for port (1) = SP
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), dtr(3)  

prtSpNoOfRetries 1.3.6.1.4.1.164.3.3.3.4.1.1.12
For DXC - this object is applicable only for port (2) = DP. The number of dialing retries requested. Default = 0
OBJECT-TYPE    
  Integer32 0..8  

prtSpWaitForConnect 1.3.6.1.4.1.164.3.3.3.4.1.1.13
For DXC - this object is applicable only for port (2) = DP. Waiting time for connect, in seconds. Default = 30 sec.
OBJECT-TYPE    
  INTEGER notApplicable(1), t30sec(2), t45sec(3), t60sec(4)  

prtSpDialMode 1.3.6.1.4.1.164.3.3.3.4.1.1.14
For DXC - this object is applicable only for port (2) = DP. Dialing mode. Default=tone
OBJECT-TYPE    
  INTEGER notApplicable(1), tone(2), pulse(3)  

prtSpAltNumMode 1.3.6.1.4.1.164.3.3.3.4.1.1.15
For DXC - this object is applicable only for port (2) = DP. It determines wether to use the alternate number or not. Default = no.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtSpPrimaryNum 1.3.6.1.4.1.164.3.3.3.4.1.1.16
For DXC - this object is applicable only for port (2) = DP. It is the Primary dialing number.
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

prtSpAltNum 1.3.6.1.4.1.164.3.3.3.4.1.1.17
For DXC - this object is applicable only for port (2) = DP. It is the Alternate dialing number. This number is applicable only if prtSpAltNumMode is 'yes'.
OBJECT-TYPE    
  DisplayString SIZE(0..20)  

prtSpRoutProtocol 1.3.6.1.4.1.164.3.3.3.4.1.1.18
This attribute indicates the routing protocol of the port. notApplicable - for DP.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtSpCmd 1.3.6.1.4.1.164.3.3.3.4.1.1.19
SP Command. For LRS this parameter will be used for a Modem Command. Upon NMS's Get operation for devices that this parameter is notApplicable, agent will send NULL string.
OBJECT-TYPE    
  OCTET STRING SIZE(20)  

prtSpActCallOut 1.3.6.1.4.1.164.3.3.3.4.1.1.20
This object indicates when to Activate Call-Out. It is used by FCD-T1/E1. always - to activate call-out always. linkFail - to activate call-out only when Link of Inband Management fails.
OBJECT-TYPE    
  INTEGER notApplicable(1), always(2), linkFail(3)  

prtSpAlrRelayMode 1.3.6.1.4.1.164.3.3.3.4.1.1.21
This attribute indicates the Alarm Relay Mode. notApplicable - for DP.
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), invert(3)  

prtSpStopBits 1.3.6.1.4.1.164.3.3.3.4.1.1.22
This attribute indicates number of stop bits in an async frame.
OBJECT-TYPE    
  INTEGER notApplicable(1), stopBits1(2), stopBits1dot5(3), stopBits2(4)  

prtDim 1.3.6.1.4.1.164.3.3.3.5
OBJECT IDENTIFIER    

prtDimCnfgTable 1.3.6.1.4.1.164.3.3.3.5.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDimCnfgEntry

prtDimCnfgEntry 1.3.6.1.4.1.164.3.3.3.5.1.1
The write operation into the Table Objects is valid only for the TmpCnfg entry (prtDimCnfgIdx=255).
OBJECT-TYPE    
  PrtDimCnfgEntry  

prtDimCnfgIdx 1.3.6.1.4.1.164.3.3.3.5.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtDimIdx 1.3.6.1.4.1.164.3.3.3.5.1.1.2
This attribute indicates a unique port number of the DIM card. The convention used for DXC: (IO slot number+10)*10 + 1 Example: port1 of IO slot 11 will be: 211 .
OBJECT-TYPE    
  Integer32  

prtDimTxMode 1.3.6.1.4.1.164.3.3.3.5.1.1.3
Tx mode. regularTx - the links are connected to a similar outfit on the other side. In this mode, if a link fails, the transmitted bandwidth is decreased accordingly. broadcast - the links are connected to MORE than one similar outfit on the other side. In this mode, if a link fails, the transmitted bandwidth is not affected
OBJECT-TYPE    
  INTEGER regularTx(2), broadcast(3)  

prtDimPolarity 1.3.6.1.4.1.164.3.3.3.5.1.1.4
Polarity.
OBJECT-TYPE    
  INTEGER normalClk(2), inverted(3)  

prtDimClkMode 1.3.6.1.4.1.164.3.3.3.5.1.1.5
Clock Mode. smooth - a clock that is not 'pulsed'(has no 'gaps'). In this mode the DXC does NOT receive back the clock signal. extSmooth - same as 'smooth' but in this mode, the DXC receives back the clock signal.
OBJECT-TYPE    
  INTEGER extDce(2), dce(3), smooth(4), extSmooth(5)  

prtDimMaxDelay 1.3.6.1.4.1.164.3.3.3.5.1.1.6
Max Delay permitted between the links, in msec.
OBJECT-TYPE    
  INTEGER t16msec(2), t64msec(3)  

prtDimMng 1.3.6.1.4.1.164.3.3.3.5.1.1.7
Use of DIM port for management. disabled - no management on DIM ts1 - 1 bit of TS1 is used for management.
OBJECT-TYPE    
  INTEGER disabled(2), ts1(3)  

prtDimDestTable 1.3.6.1.4.1.164.3.3.3.5.2
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDimDestEntry

prtDimDestEntry 1.3.6.1.4.1.164.3.3.3.5.2.1
The write operation is valid only for the TmpCnfg entry (prtDimDestCnfgIdx=255).
OBJECT-TYPE    
  PrtDimDestEntry  

prtDestCnfgIdx 1.3.6.1.4.1.164.3.3.3.5.2.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtDestDimIdx 1.3.6.1.4.1.164.3.3.3.5.2.1.2
This attribute indicates a unique port number of the DIM card. The convention used for DXC: (IO slot number+10) & 1 Example: port1 of IO slot 11 will be: 211 .
OBJECT-TYPE    
  Integer32  

prtDestIdx 1.3.6.1.4.1.164.3.3.3.5.2.1.3
This attribute indicates a destination number of the DIM card.
OBJECT-TYPE    
  Integer32 1..8  

prtDest 1.3.6.1.4.1.164.3.3.3.5.2.1.4
Destination port,(of a T1/E1 port), that is connected to the DIM card, for the specified Destination number. 0 = No destination port. Else: For external ports: (IO Slot+10) & 1 for port 1 (IO Slot+10) & 3 for port 2 Example: port2 of IO slot 12 will be: 223 . For internal ports : (IO Slot+10) & 2 for port 1 (IO Slot+10) & 4 for port 2 (IO Slot+10) & 6 for port 3 (IO Slot+10) & 8 for port 4, etc...
OBJECT-TYPE    
  Integer32  

prtDestConnect 1.3.6.1.4.1.164.3.3.3.5.2.1.5
Connection Status of the specified destination number. For a specified destination port, it depends both on the status of the port and on the status of the far-end port. Since this is a RO object, same value will be received for all configurations.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtI 1.3.6.1.4.1.164.3.3.3.6
OBJECT IDENTIFIER    

prtICnfgTable 1.3.6.1.4.1.164.3.3.3.6.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtICnfgEntry

prtICnfgEntry 1.3.6.1.4.1.164.3.3.3.6.1.1
An entry in table.
OBJECT-TYPE    
  PrtICnfgEntry  

prtICnfgIdx 1.3.6.1.4.1.164.3.3.3.6.1.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
OBJECT-TYPE    
  Integer32 1..255  

prtIIdx 1.3.6.1.4.1.164.3.3.3.6.1.1.2
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The ISDN B1, B2, D channels will be inside ports. For port index, see product specification.
OBJECT-TYPE    
  Integer32  

prtIRate 1.3.6.1.4.1.164.3.3.3.6.1.1.3
This object indicates the port rate in bits. Each TS contains 8 bits. Thus, 1 bit is equivalent to 8Kbps rate.
OBJECT-TYPE    
  INTEGER notApplicable(1), nc(2), r2bit(3), r4bit(4), r8bit(5)  

prtIConnect 1.3.6.1.4.1.164.3.3.3.6.1.1.4
D channel connection. no - disconnected yes - connected.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtHdsl 1.3.6.1.4.1.164.3.3.3.7
OBJECT IDENTIFIER    

prtHdslTable 1.3.6.1.4.1.164.3.3.3.7.1
HDSL port table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHdslEntry

prtHdslEntry 1.3.6.1.4.1.164.3.3.3.7.1.1
An entry in table.
OBJECT-TYPE    
  PrtHdslEntry  

prtHdslIdx 1.3.6.1.4.1.164.3.3.3.7.1.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The HDSL ports will be external. For port index, see product specification.
OBJECT-TYPE    
  Integer32  

prtHdslMode 1.3.6.1.4.1.164.3.3.3.7.1.1.2
This object indicates the HDSL mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), central(2), remote(3)  

prtHdslRptrType 1.3.6.1.4.1.164.3.3.3.7.1.1.3
The Repeater between Near and Far modem. none - no repeater exists between the modems hrpt - HRPT repeater exists between the modems.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), hrpt(3)  

prtHdslMaxRate 1.3.6.1.4.1.164.3.3.3.7.1.1.4
Maximum Rate of the xDSL Line, in Kbps units. This object can be Set only for a Central unit.
OBJECT-TYPE    
  INTEGER notApplicable(1), r192(2), r256(3), r320(4), r384(5), r448(6), r512(7), r576(8), r640(9), r768(10), r896(11), r1024(12), r1152(13), r1280(14), r1536(15), r1920(16), r2048(17)  

prtHdslLinkType 1.3.6.1.4.1.164.3.3.3.7.1.1.5
The Link Type. msdsl2w - MSDSL 2 Wire hdsl2w - HDSL 2 Wire hdsl4w - HDSL 4 Wire gDsl - G.DSL
OBJECT-TYPE    
  INTEGER notApplicable(1), msdsl2w(2), hdsl2w(3), hdsl4w(4), gDsl(5)  

prtHdslCompSwVer 1.3.6.1.4.1.164.3.3.3.7.1.1.6
This object indicates the Software Version of the component (Piggyback card) supporting this interface.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

prtHdslCompHwVer 1.3.6.1.4.1.164.3.3.3.7.1.1.7
This object indicates the Hardware Version of the component (Piggyback card) supporting this interface.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

prtT3E3 1.3.6.1.4.1.164.3.3.3.8
OBJECT IDENTIFIER    

prtT3E3CnfgTable 1.3.6.1.4.1.164.3.3.3.8.1
T3/E3 port configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT3E3CnfgEntry

prtT3E3CnfgEntry 1.3.6.1.4.1.164.3.3.3.8.1.1
An entry in the T3/E3 port configuration table.
OBJECT-TYPE    
  PrtT3E3CnfgEntry  

prtT3E3CnfgIdx 1.3.6.1.4.1.164.3.3.3.8.1.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For DXC, write operations can be performed only on the Temp Config. For products that do not support configurations, always 1 will be used.
OBJECT-TYPE    
  Integer32 1..255  

prtT3E3PrtIdx 1.3.6.1.4.1.164.3.3.3.8.1.1.2
This attribute indicates a unique port number. For DXC: The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The external ports convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For Optimux-T3: Link-A: 51 Link-B: 61 .
OBJECT-TYPE    
  Integer32  

prtT3E3Slt 1.3.6.1.4.1.164.3.3.3.8.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtT3E3LineLength 1.3.6.1.4.1.164.3.3.3.8.1.1.4
This object is the length of the ds3 line in feet. It provides information for line build out circuitry if it exists and can use this object to adjust the line build out. len0p450ft = 0 - 450 feet len451p900ft = 451 - 900 feet.
OBJECT-TYPE    
  INTEGER notApplicable(1), len0p450ft(2), len451p900ft(3)  

prtT3E3InbandMng 1.3.6.1.4.1.164.3.3.3.8.1.1.5
A unique number to identify the Frame Type over the link. For Optimux-T3: only values (4), (7) are supported.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), cBit(3), cBitTxRxMng(4), cBitTx(5), cBitTxMng(6), m13(7)  

prtT3E3AisFrame 1.3.6.1.4.1.164.3.3.3.8.1.1.6
This object is applicable only for Optimux-T3. It allows user to select whether the AIS sent will be framed or unframed.
OBJECT-TYPE    
  INTEGER notApplicable(1), unframed(2), framed(3)  

prtT3E3TxClockSource 1.3.6.1.4.1.164.3.3.3.8.1.1.7
Tx Clock Source.
OBJECT-TYPE    
  INTEGER external(1), internal(2), notApplicable(255)  

prtT3E3RoutProt 1.3.6.1.4.1.164.3.3.3.8.1.1.8
Routing Protocol of the port. This object is applicable only for T3 ports.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

genDacsMux 1.3.6.1.4.1.164.3.3.4
OBJECT IDENTIFIER    

cmprTable 1.3.6.1.4.1.164.3.3.4.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    CmprEntry

cmprEntry 1.3.6.1.4.1.164.3.3.4.1.1
An entry in table.
OBJECT-TYPE    
  CmprEntry  

cmprTypeIdx 1.3.6.1.4.1.164.3.3.4.1.1.1
This object indicates the Type of the Compressed data referred (which table, which level, etc). The type is a code according to a convention between agent and NMS.
OBJECT-TYPE    
  Integer32  

cmprCnfgIdx 1.3.6.1.4.1.164.3.3.4.1.1.2
This object indicates the configuration number the Compressed information relates to.
OBJECT-TYPE    
  Integer32  

cmprVersion 1.3.6.1.4.1.164.3.3.4.1.1.3
This object indicates the version of the internal format of the Compressed data (the version of the convention used).
OBJECT-TYPE    
  Integer32  

cmprSltIdx 1.3.6.1.4.1.164.3.3.4.1.1.4
This attribute indicates a unique number of the slot position where the card is inserted. When the unit is stand-alone or this object is not applicable, 255 will be used.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

cmprPrtIdx 1.3.6.1.4.1.164.3.3.4.1.1.5
This object indicates a unique identifier of the port, the compressed information relates to. For DXC - according to the order in the card of cmprSltIdx: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For FCD: see product's specification. If the port number is irrelevant to this parameter (if it is a system/card level alarm) the value will be 9999.
OBJECT-TYPE    
  Integer32  

cmprObj 1.3.6.1.4.1.164.3.3.4.1.1.6
This object is the compressed information itself, according to a predefined format, both agent and NMS agreed about.
OBJECT-TYPE    
  OCTET STRING  

mapLinkTable 1.3.6.1.4.1.164.3.3.4.2
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    MapLinkEntry

mapLinkEntry 1.3.6.1.4.1.164.3.3.4.2.1
An entry in table.
OBJECT-TYPE    
  MapLinkEntry  

mapLinkIdx 1.3.6.1.4.1.164.3.3.4.2.1.1
A unique identifier of the link
OBJECT-TYPE    
  Integer32  

mapLinkSlotIdx 1.3.6.1.4.1.164.3.3.4.2.1.2
This attribute indicates a unique slot position where the module is inserted.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

mapLinkPortIdx 1.3.6.1.4.1.164.3.3.4.2.1.3
This attribute indicates a unique port number. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
OBJECT-TYPE    
  Integer32  

mapLinkState 1.3.6.1.4.1.164.3.3.4.2.1.4
This attribute indicates the status of the link between the two muxes
OBJECT-TYPE    
  INTEGER unknown(1), down(2), up(3)  

alrGenTable 1.3.6.1.4.1.164.3.3.4.3
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    AlrGenEntry

alrGenEntry 1.3.6.1.4.1.164.3.3.4.3.1
An entry in table.
OBJECT-TYPE    
  AlrGenEntry  

alrGenCode 1.3.6.1.4.1.164.3.3.4.3.1.1
This object is a unique code number, identifying a certain alarm.
OBJECT-TYPE    
  Integer32  

alrGenDescription 1.3.6.1.4.1.164.3.3.4.3.1.2
This entry is a unique text description, of the alarm corresponding to the specified code.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

alrGenLevel 1.3.6.1.4.1.164.3.3.4.3.1.3
Alarm level.
OBJECT-TYPE    
  INTEGER notApplicable(1), system(2), card(3), port(4)  

alrGenSlotType 1.3.6.1.4.1.164.3.3.4.3.1.4
Slot type that the alarm is relevant to. clAndIo - an alarm that is relevant for both CL and IO slots.
OBJECT-TYPE    
  INTEGER notApplicable(1), ps(2), cl(3), io(4), clAndIo(5)  

alrGenSeverity 1.3.6.1.4.1.164.3.3.4.3.1.5
This object enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code).
OBJECT-TYPE    
  INTEGER notApplicable(1), event(3), minor(4), major(5), warning(6), critical(7)  

alrGenDebounce 1.3.6.1.4.1.164.3.3.4.3.1.6
Debounce time for each alarm code, in seconds. The meaning is, that an alarm will be 'declared' as ON (or OFF), only after it was actually ON/OFF the Debouncing time selected by user. 0 = default debounce selection (each alarm has a default value). 250 = maximum value of seconds for debounce. 253 = mask = the alarm will Never be reported. 254 = default debounce selection (each alarm has a default value). 255 = not applicable
OBJECT-TYPE    
  Integer32 0..255  

alrGenDefSeverity 1.3.6.1.4.1.164.3.3.4.3.1.7
This object reports the default severity of each alarm. User can change the severity of the alarms defined by this default via the alrGenSeverity object.
OBJECT-TYPE    
  INTEGER notApplicable(1), event(3), minor(4), major(5)  

modmSys 1.3.6.1.4.1.164.3.4
OBJECT IDENTIFIER    

modmSysEvents 1.3.6.1.4.1.164.3.4.0
The events for General Modems.
OBJECT-IDENTITY    

modmHubConfigChange 1.3.6.1.4.1.164.3.4.0.3
The trap is sent when any card of the modems Hub is inserted or removed.
NOTIFICATION-TYPE    
  mdlCardType  
  mdlSPanelType  

modemMasterSlaveComm 1.3.6.1.4.1.164.3.4.0.4
This trap is applicable only for IMOD modems . The trap is sent when communication between a Master modem and its Slave is stopped or resumed. 'modemMngLink' includes the modemIdx.
NOTIFICATION-TYPE    
  modemMngLink  

modemMasterChange 1.3.6.1.4.1.164.3.4.0.5
This trap is applicable only for IMOD modems . The trap is sent when a modem's permanent or temporary mode is changed. 'modemConfigMode' and 'modemModeTemporary' include the modemIdx.
NOTIFICATION-TYPE    
  modemConfigMode  
  modemModeTemporary  

mngmntControlChange 1.3.6.1.4.1.164.3.4.0.6
This trap is applicable only for LRS-12. The trap is sent when the Hub management controller is changed (NMS<->Terminal).
NOTIFICATION-TYPE    
  modmHubController  

modemInvalidParameter 1.3.6.1.4.1.164.3.4.0.7
This trap is applicable only for IMOD cards of a Hub. The trap is sent when an invalid parameter was Set to the modem.
NOTIFICATION-TYPE    
  modemIdx  

modemAlarm 1.3.6.1.4.1.164.3.4.0.8
This trap is applicable only for IMOD modems . The trap is sent when the active alarms of an IMOD modem, change.
NOTIFICATION-TYPE    
  modemActiveAlarms  

cardStatusChange 1.3.6.1.4.1.164.3.4.0.9
The trap is sent upon any change of the Leds status in the PS, CL or IMOD cards.
NOTIFICATION-TYPE    
  mdlSLed  

modemSignalingChange 1.3.6.1.4.1.164.3.4.0.10
The trap is sent for any IMOD modem, when an unmasked signal change occured in the attached variable (see modemMaskSignaling object).
NOTIFICATION-TYPE    
  modmPrtDteSignaling  

modmHubPsFail 1.3.6.1.4.1.164.3.4.0.11
The trap is sent when a PS card of the modems-Hub failed. 'mdlSLed' includes the mdlSIdx.
NOTIFICATION-TYPE    
  mdlSLed  

modmHubIPModeChange 1.3.6.1.4.1.164.3.4.0.12
The trap is sent upon any change of modmHubIpMode parameter.
NOTIFICATION-TYPE    
  modmHubIpMode  

modmInterfaceChange 1.3.6.1.4.1.164.3.4.0.13
The trap is sent upon any change of interfaces for a modem that is a card of a Hub or part of it. In order to know what changed, for each product, specific variables will be attached. These variables will be specified in the product's spec. For FOMi-E3/T3 and Optimux-4E1/T1-C : the trap will be sent when the connectors card in LRS is removed/inserted.
NOTIFICATION-TYPE    

modmRackAlarms 1.3.6.1.4.1.164.3.4.0.14
The trap is applicable for LRS-52. The trap is sent when an alarm occurs. Attached variables are detailed in product specification.
NOTIFICATION-TYPE    

modmSystem 1.3.6.1.4.1.164.3.4.1
OBJECT IDENTIFIER    

modmSa 1.3.6.1.4.1.164.3.4.1.1
OBJECT IDENTIFIER    

modmSaEvents 1.3.6.1.4.1.164.3.4.1.1.0
The events for Stand Alone Modems.
OBJECT-IDENTITY    

modmSAlarmTrap 1.3.6.1.4.1.164.3.4.1.1.0.1
The trap is sent every 5 seconds in which a change has occurred in the status of the variables sent. For modems containing a T1/E1 interface, dsx1LineStatus will be sent as well in the variables, after modmSaStatAlarms. This trap is applicable for Stand-alone modems or Agents that are cards of a Hub.
NOTIFICATION-TYPE    
  modmSaStatAlarms  

modmSLedTrap 1.3.6.1.4.1.164.3.4.1.1.0.2
The trap is sent every 5 seconds in which a change has occurred in the state of one of the LEDs. This trap is applicable for Stand-Alone modems or Agents that are cards of a Hub. 'agnLed' - will include both central and remote modems: first central, last remote.
NOTIFICATION-TYPE    
  agnLed  

modmSaConfigTable 1.3.6.1.4.1.164.3.4.1.1.1
Configuration parameters of the Central and Remote Modems. The table will be RW for a Central agent and RO for a Remote agent.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmSaConfigEntry

modmSaConfigEntry 1.3.6.1.4.1.164.3.4.1.1.1.1
An entry in table.
OBJECT-TYPE    
  ModmSaConfigEntry  

modmSaConfigMode 1.3.6.1.4.1.164.3.4.1.1.1.1.1
The mode indicates if the configuration parameters refer the Central or the Remote Modem. For AMC 102 the remote means regenerator. There can be some regenerators connecting one by the other.
OBJECT-TYPE    
  INTEGER central(1), remote(2), remote2(3), remote3(4), remote4(5), remote5(6), remote6(7), remote7(8), remote8(9), remote9(10), remote10(11)  

modmSaConfigLoopback 1.3.6.1.4.1.164.3.4.1.1.1.1.2
The possible loopbacks. It is not possible to have a remPortLoop(4) in both, Central and Remote units simultaneously.
OBJECT-TYPE    
  INTEGER noLoopback(1), localPortLoop(2), localLineLoop(3), remPortLoop(4)  

modmSaConfigAlrClearOnCmd 1.3.6.1.4.1.164.3.4.1.1.1.1.3
Setting this attribute to on, clears all the events, both from the active alarms list and from the alarms buffer. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

modmSaConfigAlrClearAllCmd 1.3.6.1.4.1.164.3.4.1.1.1.1.4
Setting this attribute to on, clears all the alarms of the alarm buffer and active alarms list. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

modmSaConfigTestClearCmd 1.3.6.1.4.1.164.3.4.1.1.1.1.5
Setting this attribute to on, clears all the user-initiated tests and loopbacks. The variable modmSaConfigLoopback should automatically change to noLoopback. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

modmSaConfigClkMaster 1.3.6.1.4.1.164.3.4.1.1.1.1.6
Modem configured as Central: External - Locked to the clock signal provided by the user's equipment by user's port. Internal - Internal oscillator. Station - Station clock (is relevant only for cards). Modem configured as Remote: External - Always locked to the recovered receive clock of the HDSL line.
OBJECT-TYPE    
  INTEGER external(2), internal(3), station(4)  

modmSaConfigResetStatistics 1.3.6.1.4.1.164.3.4.1.1.1.1.7
In the on state all statistics counters (including E1 counters) are zeroed. Upon completion, the value will automatically change to off(2). Modems that do not support statistics - the value will always be off (this object is not applicable for them). notApplicable - for modems with no statistics support.
OBJECT-TYPE    
  INTEGER off(2), on(3), notApplicable(255)  

modmSaConfigActiveTs 1.3.6.1.4.1.164.3.4.1.1.1.1.8
This object will be RO for the Remote modem. This is the number of active HDSL Time Slots, that determines user's data rate. Valid values: 1..maximum supported by the specific modem. 255 = notApplicable.
OBJECT-TYPE    
  Integer32 1..255  

modmSaConfigReset 1.3.6.1.4.1.164.3.4.1.1.1.1.9
Reset of modem. hw - HW Reset. The configured values will not change. hwAndConfig - HW Reset and initializing the default values. notApplicable - for modems with no Reset support. After 'hw' or 'hwAndConfig' is Set, agent will turn the value to 'off'.
OBJECT-TYPE    
  INTEGER off(2), hw(3), hwAndConfig(4), notApplicable(255)  

modmSaConfigRemote 1.3.6.1.4.1.164.3.4.1.1.1.1.10
This parameter enables or disables automatic configuration of the remote moden in Proxy mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

modmSaConfigPsType 1.3.6.1.4.1.164.3.4.1.1.1.1.11
The type of PS.
OBJECT-TYPE    
  INTEGER notApplicable(1), ac(2), dc(3), ac-dc(4)  

modmSaConfigWorkMode 1.3.6.1.4.1.164.3.4.1.1.1.1.12
The work mode indicates if devices work in transparent mode or termination mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), transparent(2), termination(3)  

modmSaStatTable 1.3.6.1.4.1.164.3.4.1.1.2
Status of the Central and Remote Modems.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmSaStatEntry

modmSaStatEntry 1.3.6.1.4.1.164.3.4.1.1.2.1
An entry in table.
OBJECT-TYPE    
  ModmSaStatEntry  

modmSaStatHwTest 1.3.6.1.4.1.164.3.4.1.1.2.1.1
The variable contains the results of the last hardware test. It is a sum of 2**n where n is as follows: 0 - EPROM Failure (or Database chksum error) 1 - I/O Expander Error 2 - Counter Error 3 - HDSL Framer Failure 4 - Transceiver Failure 5 - NVRAM Failure (applicable only for HCD-E1>=r3) 6 - NSFIFO Failure (applicable for HCD-E1>=r3 and HCD-4) 7 - BERT Failure (applicable only for HCD-E1>=r3) 8 - E1 Framer Failure (applicable only for HCD-E1>=r3) 9 - XRT Failure (applicable only for HCD-E1>=r3) 10- HDSL Framer 1 Failure (applicable only for HCD-4) 11- HDSL Framer 2 Failure (applicable only for HCD-4) 12- DSP 1 Failure (applicable only for HCD-4) 13- DSP 2 Failure (applicable only for HCD-4) 14- XRT 1 Failure (applicable only for HCD-4) 15- XRT 2 Failure (applicable only for HCD-4) if the variable is 0 then there are No Errors
OBJECT-TYPE    
  Integer32  

modmSaStatAlarms 1.3.6.1.4.1.164.3.4.1.1.2.1.2
The variable contains the status of the Alarms in the alarm buffer. For bit location of each Alarm in the OctetString see Modem's specification. If the value is 0 then there are No 'On' Alarms in the alarm buffer.
OBJECT-TYPE    
  OCTET STRING SIZE(10)  

modmSaStatClkSrc 1.3.6.1.4.1.164.3.4.1.1.2.1.3
This entry indicates the source of the modem clock.
OBJECT-TYPE    
  INTEGER master(1), fallback(2)  

modmSaStatAlarmsMask 1.3.6.1.4.1.164.3.4.1.1.2.1.4
This variable uses to mask alarms. Location of each Alarm Mask in the OctetString, is identical to the Alarm OctetString. If the value is 0 then none of the alarms is masked.
OBJECT-TYPE    
  OCTET STRING SIZE(10)  

modmSaStatDeviceType 1.3.6.1.4.1.164.3.4.1.1.2.1.5
This entry indicates the device type (or utility).
OBJECT-TYPE    
  INTEGER notApplicable(1), amc102SA(2), amc102Card(3)  

modmSaStatSwVersion 1.3.6.1.4.1.164.3.4.1.1.2.1.6
Display String of the modem SW version. Format: W. X Y Z 0..9 0..99 A,B,E 0..99 (Z+P are optional.) A=alpha, B=beta, E=end of development. Examples: 2.23A8 3.4
OBJECT-TYPE    
  DisplayString  

modmSaStatHwVersion 1.3.6.1.4.1.164.3.4.1.1.2.1.7
Display String of the modem HW version.
OBJECT-TYPE    
  DisplayString  

modmSaAlarmBuffTable 1.3.6.1.4.1.164.3.4.1.1.3
The alarm buffer of the Central and Remote Modems.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmSaAlarmBuffEntry

modmSaAlarmBuffEntry 1.3.6.1.4.1.164.3.4.1.1.3.1
An entry in table.
OBJECT-TYPE    
  ModmSaAlarmBuffEntry  

modmSaAlarmBuffIndex 1.3.6.1.4.1.164.3.4.1.1.3.1.1
The index of the alarm buffer Table.
OBJECT-TYPE    
  Integer32  

modmSaAlarmBuffCode 1.3.6.1.4.1.164.3.4.1.1.3.1.2
The code of the alarm. For text description of each Alarm code see Modem's specification.
OBJECT-TYPE    
  Integer32  

modmSaAlarmBuffTime 1.3.6.1.4.1.164.3.4.1.1.3.1.3
The time stamp at which the alarm has occurred. The format is hh:mm:ss
OBJECT-TYPE    
  DisplayString  

modmSaAlarmBuffState 1.3.6.1.4.1.164.3.4.1.1.3.1.4
The new status of the alarm.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

modmSaParam 1.3.6.1.4.1.164.3.4.1.1.4
OBJECT IDENTIFIER    

modmSaMode 1.3.6.1.4.1.164.3.4.1.1.4.1
The agent's current mode. For AMC 102 remote means regenerator. There can be some regenerators connecting one by the other.
OBJECT-TYPE    
  INTEGER central(1), remote(2), remote2(3), remote3(4), remote4(5), remote5(6), remote6(7), remote7(8), remote8(9), remote9(10), remote10(11)  

modmSaFarEndIpAddress 1.3.6.1.4.1.164.3.4.1.1.4.2
The IP address of the agent on the far end. If the Remote modem is NOT an agent, the variable will be 0.0.0.0. Set - will be enabled only to a Central modem that works as Proxy.
OBJECT-TYPE    
  IpAddress  

modmSaFarEndType 1.3.6.1.4.1.164.3.4.1.1.4.3
The type of the Far-End modem.
OBJECT-TYPE    
  INTEGER unknown(1), sa(2), card(3), saLowCost(4), hcdSa(5), hcdSaL(6), hcdCard(7), htu2Sa(8), htu2Card(9), htuE1Sa(10), htuE1SaL(11), htuE1Card(12), hcd4Sa(13), hcdPF(14), unmanaged(100)  

modmSaRptrType 1.3.6.1.4.1.164.3.4.1.1.4.4
The Repeater between the Near and Far modem. none - no repeater exists between the modems. notApplicable - for modems that do not support this feature.
OBJECT-TYPE    
  INTEGER none(2), hrpt(3), notApplicable(255)  

modmSaLearnLineMode 1.3.6.1.4.1.164.3.4.1.1.4.5
This parameter is for the central unit only. Indicates if learn the regenerator order and number every time there is a fail in line or manually by user.
OBJECT-TYPE    
  INTEGER notApplicable(1), manually(2), automatic(3)  

modmSaNumOfUnits 1.3.6.1.4.1.164.3.4.1.1.4.6
This object will hold the number of regenerators in the line.
OBJECT-TYPE    
  Integer32  

modmSaRptrTable 1.3.6.1.4.1.164.3.4.1.1.5
The Repeaters parameters known to the central modem.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmSaRptrEntry

modmSaRptrEntry 1.3.6.1.4.1.164.3.4.1.1.5.1
An entry in table.
OBJECT-TYPE    
  ModmSaRptrEntry  

modmSaIndex 1.3.6.1.4.1.164.3.4.1.1.5.1.1
A unique number to identify the modem that reports about the repeater.
OBJECT-TYPE    
  Integer32  

modmSaRptrIndex 1.3.6.1.4.1.164.3.4.1.1.5.1.2
The index of the Repeater.
OBJECT-TYPE    
  Integer32  

modmSaRptrTest 1.3.6.1.4.1.164.3.4.1.1.5.1.3
The possible loopbacks.
OBJECT-TYPE    
  INTEGER none(1), loopLHrpt(2)  

modmSaRptrActiveAlarms 1.3.6.1.4.1.164.3.4.1.1.5.1.4
Status of the Alarms. Each bit represents a specific alarm . For bit location of each alarm in the Octet String see modem's specification. If the value is 0 then there are No Alarms.
OBJECT-TYPE    
  OCTET STRING  

modmSaRptrAlrClear 1.3.6.1.4.1.164.3.4.1.1.5.1.5
Setting this attribute to on, clears all the active (On) alarms of the repeater. Upon completion, the value will automatically change to off(2)..
OBJECT-TYPE    
  INTEGER off(1), on(2)  

modmSaRptrVersion 1.3.6.1.4.1.164.3.4.1.1.5.1.6
SW/HW version of the repeater
OBJECT-TYPE    
  DisplayString  

modmHub 1.3.6.1.4.1.164.3.4.1.2
OBJECT IDENTIFIER    

modmHubParam 1.3.6.1.4.1.164.3.4.1.2.1
OBJECT IDENTIFIER    

modmHubTermConnect 1.3.6.1.4.1.164.3.4.1.2.1.1
Status: is the Terminal connected or not.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

modmHubController 1.3.6.1.4.1.164.3.4.1.2.1.2
Selection of Hub controller during normal operation. If 'terminal' is selected, NMS can still return control to itself by setting this object to 'nms'. While terminal is the controller, NMS can perform Get operations and Set trap masks.
OBJECT-TYPE    
  INTEGER nms(1), terminal(2)  

modmHubId 1.3.6.1.4.1.164.3.4.1.2.1.3
4 Hex characters, identifying the Hub. The last two characters (least significant) will be displayed on the Hub's CL card by a 7 segment display.
OBJECT-TYPE    
  OCTET STRING SIZE(2)  

modmHubT1E1 1.3.6.1.4.1.164.3.4.1.2.1.4
The T1/E1 value determines the Hub's clock rate.
OBJECT-TYPE    
  INTEGER other(1), t1(2), e1(3)  

modmHubClockSource 1.3.6.1.4.1.164.3.4.1.2.1.5
Clock source.
OBJECT-TYPE    
  INTEGER other(1), external(2), internal(3), g703Section10(4), receive(5), station(6)  

modmHubClockRate 1.3.6.1.4.1.164.3.4.1.2.1.6
Clock Rate in bps. The rates are the original T1/E1 rates or the rates divided by 2n. For modmHubT1E1=e1, instances (1)-(9) are applicable. For modmHubT1E1=t1, instances (31)-(36) are applicable. For modmHubT1E1=other, instance (255) is applicable.
OBJECT-TYPE    
  INTEGER e1r2048000(1), e1r1024000(2), e1r512000(3), e1r256000(4), e1r128000(5), e1r64000(6), e1r32000(7), e1r16000(8), e1r8000(9), t1r1544000(31), t1r772000(32), t1r386000(33), t1r193000(34), t1r96500(35), t1r48250(36), notApplicable(255)  

modmHubIpMode 1.3.6.1.4.1.164.3.4.1.2.1.7
single - Upon BootP request from S-MOD, CM-2 will assign a 'private IP' (CM-2 IP + slot number of S-MOD), which will be applicable only between the S-MOD and CM-2. multi - CM-2 assigns up to 12/24 consequent IP addresses. One for each S-MOD according to the slot number.
OBJECT-TYPE    
  INTEGER single(1), multi(2)  

modmHubInstallation 1.3.6.1.4.1.164.3.4.1.2.1.8
The string will be a multiple set of 16 bit corresponds to its card position, and each set corresponds to a modem, where set #1 is the first modem on each card, and set n is the n-st modem in each card. 1........10.....16|1........10.....16| modem 1 | modem 2 | MSB LSB Bits 1-3 and 16 will be ignored. For LRS-52 detailed bit assignment see product's spec.
OBJECT-TYPE    
  OCTET STRING  

modmHubAlarms 1.3.6.1.4.1.164.3.4.1.2.2
OBJECT IDENTIFIER    

modmHubActiveAlarms 1.3.6.1.4.1.164.3.4.1.2.2.1
Status of the Alarms for each Slot. Each bit represents a Slot of the Hub. For bit location of each Alarm in the Octet String see Hub's specification. A bit is '1' (On) if at least one 'On' alarm exists for this Slot. If the value is 0 then there are No 'On' Alarms in any Slot. For LRS52 - read 'modem' instead of the word 'slot'
OBJECT-TYPE    
  OCTET STRING  

modmHubAlrClear 1.3.6.1.4.1.164.3.4.1.2.2.2
Setting this attribute to on, clears all the active (On) alarms of the Hub. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

modmHubMaskAlarms 1.3.6.1.4.1.164.3.4.1.2.2.3
Mask of Alarms per Slot. Each bit represents a Slot of the Hub. For bit location of each Slot in the Octet String see Hub's specification (same as modmHubActiveAlarms). When a bit is '1' (On) it is masked ; all alarms of this Slot should not be sent and Alarm LED should not be lit. This mask overrides the mask on the specific alarms of each Slot or modem. If the value is 0 then all alarms should be sent. For LRS52 - read 'modem' instead of the word 'slot'.
OBJECT-TYPE    
  OCTET STRING  

modmMdl 1.3.6.1.4.1.164.3.4.2
OBJECT IDENTIFIER    

modmMdlParam 1.3.6.1.4.1.164.3.4.2.1
OBJECT IDENTIFIER    

mdlParamTable 1.3.6.1.4.1.164.3.4.2.1.1
Parameters table of cards in the Hub.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlParamEntry

mdlParamEntry 1.3.6.1.4.1.164.3.4.2.1.1.1
An entry in table.
OBJECT-TYPE    
  MdlParamEntry  

mdlSIdx 1.3.6.1.4.1.164.3.4.2.1.1.1.1
A unique number to identify a slot position in the modems Hub.
OBJECT-TYPE    
  INTEGER psA(1), psB(2), cl(3), io1(4), io2(5), io3(6), io4(7), io5(8), io6(9), io7(10), io8(11), io9(12), io10(13), io11(14), io12(15)  

mdlSNoOfModems 1.3.6.1.4.1.164.3.4.2.1.1.1.2
Number of modems on this card. 255 = notApplicable.
OBJECT-TYPE    
  Integer32  

mdlCardType 1.3.6.1.4.1.164.3.4.2.1.1.1.3
Card's type.
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), ps48V(3), ps110V(4), ps230V(5), cm2(6), smod(7), asmi24(8), asmi31(9), asmi32(10), asmi50(11), mtmi20(12), fomi40(13), fomiE1T1(14), asm40cd(15), asmi50cd(16), fomi40cd(17), fomiE1T1cd(18), ps110V-24(19), ps230V-24(20), ps48V-24(21), asmi31cq(22), asmi51cq(23), asmi51cd(24), asmi52cd(25), asmi52cq(26), fomiE3(51), fomiT3(52), optimux4E1(53), optimux4T1(54), amc102(55), notApplicable(255)  

mdlSPanelType 1.3.6.1.4.1.164.3.4.2.1.1.1.4
LRS-12 Card connectors' panel type. fx - IMOD panels psxxx - PS panels fxCm2 - CM-2 panels.
OBJECT-TYPE    
  INTEGER empty(1), f2(2), f3(3), f5(5), f6(6), f7(7), f9(9), f10(10), f11(11), f12(12), f13(13), f14(14), f18(15), f19(16), f22(17), f20(18), f21(19), f23(20), fO1(21), fO2(22), fO3(23), fO4(24), fO5(25), fO6(26), fO7(27), fO8(28), fO9(29), fO10(30), fO11(31), fO12(32), fO13(33), fO14(34), fO15(35), fO16(36), fO17(37), fO18(38), fO19(39), fO20(40), fO21(41), fO22(42), ps230And115(81), psp230And115(82), ps48(83), psp48(84), f1Cm2(91), f2Cm2(92), f3Cm2(93), f4Cm2(94), f5Cm2(95), f1Cm2New(96), notApplicable(255)  

mdlSLed 1.3.6.1.4.1.164.3.4.2.1.1.1.5
LEDs status on the card . Each led will be represented by 4 bits where the first 2 bits (left) will specify the Status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) will specify the Color : (00=GREEN, 01=RED, 10=YELLOW, 11=ORANGE). This object is not applicable for the 'smod', 'empty' and 'unknown' card types. For them 0 will be sent.
OBJECT-TYPE    
  OCTET STRING  

mdlSActiveAlarms 1.3.6.1.4.1.164.3.4.2.1.1.1.6
This object is applicable only for PS and CL cards. It gives the status of the Alarms for each Slot. Each bit represents an alarm in the slot. For bit location of each Alarm in the Octet String see Hub's specification. A bit is '1' if the alarm is On. If the value is 0 then there are No 'On' Alarms in the Slot.
OBJECT-TYPE    
  OCTET STRING  

mdlAlrClear 1.3.6.1.4.1.164.3.4.2.1.1.1.7
Setting this attribute to on, clears all the active (On) alarms of the Slot. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSConfigMismatch 1.3.6.1.4.1.164.3.4.2.1.1.1.8
This object is applicable only for slots containing IMOD cards. ON - when CM-2 realizes that the configuration of the Near-End modem1 is different from that of its Far-End modem. In this case it expects user to decide which of the modems' configuration is the correct one (by 'mdlConfigSource'), or change the incorrect modem configuration. When one of these conditions is fulfilled, the value will automatically turn to OFF. Applicable for a single modem. Line1 - The same as for ON but for modem-1 line. Applicable for a double modem. Line2 - The same as for ON but for modem-2 line. Applicable for a double modem. OFF - Near-End and Far-End modems have the same configuration (OK).
OBJECT-TYPE    
  INTEGER off(2), on(3), line1(4), line2(5), notApplicable(255)  

mdlConfigSource 1.3.6.1.4.1.164.3.4.2.1.1.1.9
This object is applicable only for slots containing IMOD cards, when mdlSConfigMismatch=on/on1/on2. nearEnd - Near End - 1 modem has the correct configuration farEnd - Far End - 1 has the correct configuration nearEnd - Near End - 2 has the correct configuration farEnd - Far End - 2 has the correct configuration.
OBJECT-TYPE    
  INTEGER nearEnd(1), farEnd(2), nearEnd2(3), farEnd2(4), notApplicable(255)  

mdlConfigGround 1.3.6.1.4.1.164.3.4.2.1.1.1.10
Enables to connect or disconnect an IMOD card to the ground. disconnect - not connected to ground. connect - connected to ground. notApplicable - for other cards.
OBJECT-TYPE    
  INTEGER notApplicable(1), disconnect(2), connect(3)  

modem 1.3.6.1.4.1.164.3.4.3
OBJECT IDENTIFIER    

modemParam 1.3.6.1.4.1.164.3.4.3.1
OBJECT IDENTIFIER    

modemParamTable 1.3.6.1.4.1.164.3.4.3.1.1
This parameters table is applicable only for modems that are not agents.
OBJECT-TYPE    
  SEQUENCE OF  
    ModemParamEntry

modemParamEntry 1.3.6.1.4.1.164.3.4.3.1.1.1
An entry in table.
OBJECT-TYPE    
  ModemParamEntry  

modemIdx 1.3.6.1.4.1.164.3.4.3.1.1.1.1
For LRS: A unique number to identify a modem in the Hub or its far-end modem. For DXC: This will be the ifIndex of the External Port of DSL16 card, that works with this modem/product.
OBJECT-TYPE    
  Integer32  

modemType 1.3.6.1.4.1.164.3.4.3.1.1.1.2
Modem type. xxxxxx - Stand-Alone modem. xxxxxxc - Modem on a Card within a Hub having an Agent. xxxxxxr - Modem on a Card within a Hub having no Agent. xxxxxxcd - Modem on a Double-Modem Card within a Hub having an Agent. Each modem has it's own CPU. xxxxxxcq - Modem on a Quad-Modem Card within a Hub having an Agent. One CPU for all modems. lrs52 - Modem within the LRS-52 device.
OBJECT-TYPE    
  INTEGER unknown(1), asmi24c(2), asmi31c(3), asmi32c(4), asmi50c(5), mtmi20c(6), fomi40c(7), fomiE1T1c(8), asm40cd(9), asmi31cq(10), asmi51cq(11), asmi51cd(12), asmi52cq(13), asmi52cd(14), asmi24r(22), asmi31r(23), asmi32r(24), asmi50r(25), mtmi20r(26), asmi24(42), asmi31(43), asmi32(44), asmi50(45), mtmi20(46), fomi40(47), fomiE1T1(48), asmi51(49), asmi52S(50), asmi52M(51), lrs52(71)  

modemConfigMode 1.3.6.1.4.1.164.3.4.3.1.1.1.3
The mode identifies if the Modem operates as the Master unit or as the Slave unit. For modems having a jumper for this function, this object will be RO. This object can be Set only to the Master unit when modemModeTemporary=no (the Far-End unit will receive its new mode from the Central unit, via management link between the modems). Regarding other objects (except modemModeTemporary): If Modem is Master, it can perform RW operations for both Master and Slave modem. If Modem is Slave, it can perform RO operations for both Master and Slave modem.
OBJECT-TYPE    
  INTEGER master(1), slave(2)  

modemModeTemporary 1.3.6.1.4.1.164.3.4.3.1.1.1.4
This object specifies if the Modem operates as modemConfigMode value (Master/Slave) temporarily or permanently. This object can be Set only when: - modemConfigMode=master AND modemModeTemporary=no - modemConfigMode=slave AND modemModeTemporary=yes this is an exception to the fact that all other objects in this case are RO. The other unit will receive its value for this object from the Set unit, via management link between the modems.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

modemNoOfDte 1.3.6.1.4.1.164.3.4.3.1.1.1.5
Number of DTE ports in the modem.
OBJECT-TYPE    
  Integer32  

modemWire 1.3.6.1.4.1.164.3.4.3.1.1.1.6
Modem wiring.
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2), notApplicable(255)  


modemReset 1.3.6.1.4.1.164.3.4.3.1.1.1.8
When this object is set to the value of hwReset(3), the module performs HW Reset. When this object is set to the value of configReset(4), the modem performs Configuration Reset, which will set the modem to the last parameters it was configured.
OBJECT-TYPE    
  INTEGER off(2), hwReset(3), configReset(4)  

modemSlot 1.3.6.1.4.1.164.3.4.3.1.1.1.9
A unique number to identify the slot position of the modem (card)in its Hub. notApplicable - for a stand-alone modem or Rack 214 card. io13..io15 - are for DXC use in case of a Far-Unit that is DSL16 card.
OBJECT-TYPE    
  INTEGER io1(4), io2(5), io3(6), io4(7), io5(8), io6(9), io7(10), io8(11), io9(12), io10(13), io11(14), io12(15), io13(16), io14(17), io15(18), notApplicable(255)  

modemHubId 1.3.6.1.4.1.164.3.4.3.1.1.1.10
4 Hex characters, identifying the Hub. The last two characters (least significant) will be displayed on the Hub's CL card by a 7 segment display. This object is applicable only for LRS-12 modems.
OBJECT-TYPE    
  OCTET STRING SIZE(2)  

modemIpAddress 1.3.6.1.4.1.164.3.4.3.1.1.1.11
For LRS: The IP address of the LRS-12 agent . If the modem is NOT an LRS-12 card, the variable will be 0.0.0.0. For DXC: the IP Address of the Far-End unit.
OBJECT-TYPE    
  IpAddress  

modemPsType 1.3.6.1.4.1.164.3.4.3.1.1.1.12
The type of PS, for a stand-alone modem. notApplicable - for LRS-12 or Rack 214 card.
OBJECT-TYPE    
  INTEGER ac(1), dc(2), notApplicable(255)  

modemMaskTraps 1.3.6.1.4.1.164.3.4.3.1.1.1.13
The value determines the modem traps the agent should mask and not send to the management console. The value is a sum of 2**n, where n is a bit assigned to a certain trap. For bit assignment see modem's specification. Value of '0', means that no trap should be masked.
OBJECT-TYPE    
  Integer32  

modemActiveAlarms 1.3.6.1.4.1.164.3.4.3.1.1.1.14
Status of the Alarms for each modem. Each bit represents an alarm. For bit location of each Alarm in the Octet String see modem's specification. A bit is '1' if the alarm is On. If the value is 0 then there are no 'On' alarms on this modem.
OBJECT-TYPE    
  OCTET STRING  

modemAlrClear 1.3.6.1.4.1.164.3.4.3.1.1.1.15
Setting this attribute to on, clears all the active (On) alarms of the modem. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

modemAlrBufClear 1.3.6.1.4.1.164.3.4.3.1.1.1.16
Setting this attribute to on, clears all the alarms in the buffer alarm of the modem. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

modemMaskSignaling 1.3.6.1.4.1.164.3.4.3.1.1.1.17
Mask of Signals per modem. When a signal is masked, the agent will not send the modemSignalingChange TRAP, upon change of this signal's value and it will not enter the History Log. Each bit represents a signal of the modem. For bit location of each signal in the Octet String see modem's specification. When a bit is '1' (On) it is masked .
OBJECT-TYPE    
  OCTET STRING  

modemPanelType 1.3.6.1.4.1.164.3.4.3.1.1.1.18
The panel type of the modem. This parameter is applicable only for Far-End modems that are stand-alone or cards of another LRS-12. It enables displaying the correct panel of the modem. - Stand-alone : applicable only for ASMi-24 and ASMi-50 modems. pcu - with connector for Portable Control Unit lcd - LCD display and buttons. - LRS-12 card : fx is the connectors panel of the modem.
OBJECT-TYPE    
  INTEGER f2(2), f3(3), f7(7), f9(9), f10(10), f11(11), f12(12), fO1(21), fO2(22), fO3(23), fO4(24), fO5(25), fO6(26), fO7(27), fO8(28), fO9(29), fO10(30), pcu(101), lcd(102), notApplicable(255)  

modemIType 1.3.6.1.4.1.164.3.4.3.1.1.1.19
Is the modem Intelligent (ASMi-xx) ; or not - (ASM-xx). This object is used only for the Far-End modem (with the relevant modemIdx). notApplicable - for ASMi-32, ASMi-50 no - modem is NOT I-Type so it doesn't have a management link to its pair-modem. yes - modem is I-Type so it has a management link to its pair-modem.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

modemRcvPower 1.3.6.1.4.1.164.3.4.3.1.1.1.20
The Rx Level of the modem, in dBm. Valid values: -99 .. 0. 255=not applicable.
OBJECT-TYPE    
  Integer32  

modemSwVersion 1.3.6.1.4.1.164.3.4.3.1.1.1.21
SW version of the modem, multiplied by 100. Example: 115 means SW ver: 1.15 0 = notApplicable.
OBJECT-TYPE    
  Integer32  

modemLed 1.3.6.1.4.1.164.3.4.3.1.1.1.22
LEDs status on the card . Each led will be represented by 4 bits where the first 2 bits (left) will specify the Status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) will specify the Color : (00=GREEN, 01=RED, 10=YELLOW, 11=ORANGE). This object is applicable for modems located on a card that contains more than one modem. When not applicable 0 will be sent.
OBJECT-TYPE    
  OCTET STRING  

modemRemoteType 1.3.6.1.4.1.164.3.4.3.1.1.1.23
Remote modem card type. Not applicable to near - end modems. For LRS-52, sa(3)=saMaster.
OBJECT-TYPE    
  INTEGER notApplicable(1), unknown(2), sa(3), single(4), double(5), rack(6), quad(7), saSlave(8), fcd(9), dxcCard4p(10), dxcCard8p(11), lrs52(12)  

modemConfigPhantom 1.3.6.1.4.1.164.3.4.3.1.1.1.24
Enables to supply electric power to remote devices (SA modem, repeaters), through the current module. off - remote devices will not get PS through the current modem. on - remote devices will get PS through the current modem. notApplicable - for a modem without a phantom unit. notValid - In case the unit exists but is not functioning.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3), notValid(4)  

modemRemoteTestEnable 1.3.6.1.4.1.164.3.4.3.1.1.1.25
This parameter identifies if the remote Modem allowed to operates tests. For Near-End modems this parameter will be ON.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

modemSwVerString 1.3.6.1.4.1.164.3.4.3.1.1.1.26
Display String of the modem SW version. Format: X. Y Z P 0..9 0..99 A,B,E 0..99 (Z+P are optional.) A=alpha, B=beta, E=end of development. Examples: 2.23A8 3.4
OBJECT-TYPE    
  DisplayString  

modemRemoteIdx 1.3.6.1.4.1.164.3.4.3.1.1.1.27
0 = notApplicable. For LRS: The Remote modem index. Applicable only for modemRemoteType=double(5) or quad(7). For DXC and LRS-52: - if Remote unit is an LRS Quad card: remote modem index (1..4) - if Remote unit is a DXC DSL16 card: external port index (1..16). - if Remote unit is an LRS-52 modem: 1..24.
OBJECT-TYPE    
  Integer32  

modemHwVerString 1.3.6.1.4.1.164.3.4.3.1.1.1.28
Display String of the modem HW version.
OBJECT-TYPE    
  DisplayString  

modemResetStatistics 1.3.6.1.4.1.164.3.4.3.1.1.1.29
In the on state all statistics counters (including E1 counters) are zeroed. Upon completion, the value will automatically change to off(2). notApplicable - for modems with no statistics support.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

modemMaxRate 1.3.6.1.4.1.164.3.4.3.1.1.1.30
Maximum rate supported by the modem
OBJECT-TYPE    
  INTEGER notApplicable(1), r2Mbps(2), r4Mbps(3)  

modemBoxMaterial 1.3.6.1.4.1.164.3.4.3.1.1.1.31
Shape (picture) of modem box is related to box material. Applicable for ASMi52 SA
OBJECT-TYPE    
  INTEGER notApplicable(1), plastic(2), metal(3)  

modemAlrBuffer 1.3.6.1.4.1.164.3.4.3.2
OBJECT IDENTIFIER    

modemAlrBufTable 1.3.6.1.4.1.164.3.4.3.2.1
This parameters table is applicable only for modems that are not agents.
OBJECT-TYPE    
  SEQUENCE OF  
    ModemAlrBufEntry

modemAlrBufEntry 1.3.6.1.4.1.164.3.4.3.2.1.1
An entry in table.
OBJECT-TYPE    
  ModemAlrBufEntry  

modemAlrBufIdx 1.3.6.1.4.1.164.3.4.3.2.1.1.1
Running index of the alarm buffer table.
OBJECT-TYPE    
  Integer32  

modemAlrBufCode 1.3.6.1.4.1.164.3.4.3.2.1.1.2
The code of the alarm. For text description of each Alarm code see Modem's specification.
OBJECT-TYPE    
  Integer32  

modemAlrBufState 1.3.6.1.4.1.164.3.4.3.2.1.1.3
The new status of the alarm.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

modemAlrBufDate 1.3.6.1.4.1.164.3.4.3.2.1.1.4
The Date at which the alarm has occurred. The format is according to the entered systemDate format.
OBJECT-TYPE    
  DisplayString  

modemAlrBufTime 1.3.6.1.4.1.164.3.4.3.2.1.1.5
The time stamp at which the alarm has occurred. The format is hh:mm:ss
OBJECT-TYPE    
  DisplayString  

modemAlrBufSysUpTime 1.3.6.1.4.1.164.3.4.3.2.1.1.6
The value of sysUpTime at the time the alarm has occurred. This object is applicable only for products that cannot support calendar date (modemAlrBufDate) and time (modemAlrBufTime) When not applicable, this object contains a zero value
OBJECT-TYPE    
  TimeTicks  

modemStatistics 1.3.6.1.4.1.164.3.4.3.3
OBJECT IDENTIFIER    

modemGeneralTable 1.3.6.1.4.1.164.3.4.3.3.1
The IMOD General data Table. The data is specific to each modem.
OBJECT-TYPE    
  SEQUENCE OF  
    ModemGeneralEntry

modemGeneralEntry 1.3.6.1.4.1.164.3.4.3.3.1.1
An entry in the modemGeneralTable. This entry is per modem. Each modem has a specific index, which identifies it.
OBJECT-TYPE    
  ModemGeneralEntry  

modemCurrentElapsedTime 1.3.6.1.4.1.164.3.4.3.3.1.1.1
The number of seconds that have elapsed since the beginning of the current error-measurement period.
OBJECT-TYPE    
  Integer32 0..899  

modemValidIntervals 1.3.6.1.4.1.164.3.4.3.3.1.1.2
The number of previous intervals for which data was collected. The value will be 96 unless the interface was brought on-line within the last 24 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online.
OBJECT-TYPE    
  Integer32 0..96  

modemIntervalTable 1.3.6.1.4.1.164.3.4.3.3.2
The IMOD Interval Table. The data is specific to each modem.
OBJECT-TYPE    
  SEQUENCE OF  
    ModemIntervalEntry

modemIntervalEntry 1.3.6.1.4.1.164.3.4.3.3.2.1
An entry in the modemIntervalTable. This entry is per modem and per interval selected.
OBJECT-TYPE    
  ModemIntervalEntry  

modemIntervalNumber 1.3.6.1.4.1.164.3.4.3.3.2.1.1
The number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid). Maximum valid number is modemValidIntervals.
OBJECT-TYPE    
  Integer32 1..96  

modemSyncLoss 1.3.6.1.4.1.164.3.4.3.3.2.1.2
Percent of interval, SyncLoss signal is ON. 101 = notApplicable/unknown.
OBJECT-TYPE    
  Integer32 0..101  

modemLineQuality 1.3.6.1.4.1.164.3.4.3.3.2.1.3
Quality of Line for the selected modem, in the selected valid interval.
OBJECT-TYPE    
  INTEGER notApplicable(1), bad(2), mid(3), good(4), unknown(5), syncLoss(6)  

modemLineUtility 1.3.6.1.4.1.164.3.4.3.3.2.1.4
Percent of interval, Line is utilized. 101 = notApplicable/unknown.
OBJECT-TYPE    
  Integer32 0..101  

modemRTS 1.3.6.1.4.1.164.3.4.3.3.2.1.5
Percent of interval, RTS signal is ON. 101 = notApplicable/unknown.
OBJECT-TYPE    
  Integer32 0..101  

modemCD 1.3.6.1.4.1.164.3.4.3.3.2.1.6
Percent of interval, CD signal is ON. 101 = notApplicable/unknown.
OBJECT-TYPE    
  Integer32 0..101  

modemBertResult 1.3.6.1.4.1.164.3.4.3.3.2.1.7
Result of BERT for the selected modem, in the selected valid interval.
OBJECT-TYPE    
  DisplayString  

modemBpvError 1.3.6.1.4.1.164.3.4.3.3.2.1.8
BPV Error. The Octet will be built as follows: MSB 7 6 5 4 3 2 1 0 LSB |__| |______________| y=0..3 x=0..63 BPV Error = x * (10**y) An Agent that does not support this object will send Size=0.
OBJECT-TYPE    
  OCTET STRING SIZE(0..1)  

modemFoError 1.3.6.1.4.1.164.3.4.3.3.2.1.9
FO Error. The Octet will be built as follows: MSB 7 6 5 4 3 2 1 0 LSB |__| |______________| y=0..3 x=0..63 FO Error = x * (10**y) An Agent that does not support this object will send Size=0.
OBJECT-TYPE    
  OCTET STRING SIZE(0..1)  

modmPrt 1.3.6.1.4.1.164.3.4.4
OBJECT IDENTIFIER    

modmSpPort 1.3.6.1.4.1.164.3.4.4.1
OBJECT IDENTIFIER    

modmPrtSpTable 1.3.6.1.4.1.164.3.4.4.1.1
Configuration parameters of the Local or Remote Modem Supervisory Ports. The port will be identified by its specific ifIndex value.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmPrtSpEntry

modmPrtSpEntry 1.3.6.1.4.1.164.3.4.4.1.1.1
An entry in table.
OBJECT-TYPE    
  ModmPrtSpEntry  

modmPrtSpUsage 1.3.6.1.4.1.164.3.4.4.1.1.1.1
This attribute indicates what is the usage of the port.
OBJECT-TYPE    
  INTEGER nmsSlip(2), terminal(3), agentSlip(4), nmsPpp(5), agentPpp(6)  

modmPrtSpRate 1.3.6.1.4.1.164.3.4.4.1.1.1.2
This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent.
OBJECT-TYPE    
  INTEGER auto(1), s300bps(2), s1200bps(3), s2400bps(4), s4800bps(5), s9600bps(6)  

modmPrtSpDataBits 1.3.6.1.4.1.164.3.4.4.1.1.1.3
This attribute indicates the number of data bits in the word format.
OBJECT-TYPE    
  INTEGER dataBits7(1), dataBits8(2)  

modmPrtSpParity 1.3.6.1.4.1.164.3.4.4.1.1.1.4
This attribute indicates the parity mode in async frame
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3)  

modmPrtSpInterface 1.3.6.1.4.1.164.3.4.4.1.1.1.5
This attribute indicates the supervisory port interface. dce - the modem appears as a DCE for the SP port. dte - the modem operates as a DTE, for connection via modem, for the SP port.
OBJECT-TYPE    
  INTEGER dce(1), dte(2)  

modmPrtSpCTS 1.3.6.1.4.1.164.3.4.4.1.1.1.6
CTS line state.
OBJECT-TYPE    
  INTEGER on(2), rts(3)  

modmPrtSpDcdDelay 1.3.6.1.4.1.164.3.4.4.1.1.1.7
DCD delay in msec. d10 = delay of 10msec.
OBJECT-TYPE    
  INTEGER d0(2), d10(3), d50(4), d100(5), d200(6), d300(7)  

modmPrtSpDsr 1.3.6.1.4.1.164.3.4.4.1.1.1.8
DSR line state.
OBJECT-TYPE    
  INTEGER on(2), dtr(3)  

modmDs1Port 1.3.6.1.4.1.164.3.4.4.2
OBJECT IDENTIFIER    

modmPrtDs1Table 1.3.6.1.4.1.164.3.4.4.2.1
Statistics parameters of the Local and Remote modem Ds1 ports. The port will be identified by its specific ifIndex value.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmPrtDs1Entry

modmPrtDs1Entry 1.3.6.1.4.1.164.3.4.4.2.1.1
An entry in table.
OBJECT-TYPE    
  ModmPrtDs1Entry  

modmPrtDs1HdslPriorityBumping 1.3.6.1.4.1.164.3.4.4.2.1.1.1
The 4 bytes represent the 32 time slots of the E1 frame. Each bit can be set to one, making the corresponding time slot a HIGH priority. Bits 16 and 32 cannot be modified by the user. The maximum number of HIGH priority time slots is 16. The default value is LOW, i.e., 0. This variable is RO in the Remote unit.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

modmPrtDs1Sync 1.3.6.1.4.1.164.3.4.4.2.1.1.2
The standard used for the time required for the E1 port to return to normal operation after local loss of synchronization. Default: itu(2).
OBJECT-TYPE    
  INTEGER itu(2), fast(3), s62411(4)  

modmPrtDs1BpvLastMin 1.3.6.1.4.1.164.3.4.4.2.1.1.3
This object is applicable only for an E1 active port. It provides the number of BPV (BiPolar Violation) events detected during the last minute.
OBJECT-TYPE    
  Gauge32  

modmPrtDs1BpvMax 1.3.6.1.4.1.164.3.4.4.2.1.1.4
This object is applicable only for an E1 active port. It provides the maximal number of BPV (BiPolar Violation) events (per minute), detected during the worst minute.
OBJECT-TYPE    
  Gauge32  

modmPrtDs1LineLength 1.3.6.1.4.1.164.3.4.4.2.1.1.5
This attribute is the line length mask parameter used only for T1/DSU interfaces. len400p533ft=length range: 400ft to 533ft 'fcc68' - provides compliance with the FCC 68.308 Option A output pulse mask.
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), fcc68(7), notApplicable(255)  

modmPrtDs1CRCAvgError 1.3.6.1.4.1.164.3.4.4.2.1.1.6
Counts the average number of CRC error events per second. The average is updated every second
OBJECT-TYPE    
  Gauge32  

modmHdslPort 1.3.6.1.4.1.164.3.4.4.3
OBJECT IDENTIFIER    

modmPrtHdslCurrentTable 1.3.6.1.4.1.164.3.4.4.3.1
The HDSL Current Table. The data collected is for the current 15-minute interval.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmPrtHdslCurrentEntry

modmPrtHdslCurrentEntry 1.3.6.1.4.1.164.3.4.4.3.1.1
An entry in the HDSL Current Table. This entry is per HDSL interface (LOOP1 or LOOP2). Each modem (Central/Remote) has a specific ifIndex value for the port, which identifies it.
OBJECT-TYPE    
  ModmPrtHdslCurrentEntry  

modmPrtHdslCurrentElapsedTime 1.3.6.1.4.1.164.3.4.4.3.1.1.1
The number of seconds that have elapsed since the beginning of the current error-measurement period.
OBJECT-TYPE    
  Integer32 0..899  

modmPrtHdslCurrentESs 1.3.6.1.4.1.164.3.4.4.3.1.1.2
The number of Errored Seconds encountered by an HDSL interface in the current 15 minute interval. An Errored Second is any second containing one or more Errored Blocks or an occurrence of an SDP.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslCurrentSESs 1.3.6.1.4.1.164.3.4.4.3.1.1.3
The number of Severely Errored Seconds encountered by an HDSL interface in the current 15 minute interval. An SES is any second containing more than 30% Errored Blocks (50 blocks) or one or more SDPs.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslCurrentBBEs 1.3.6.1.4.1.164.3.4.4.3.1.1.4
The number of Background Block Errors encountered by an HDSL interface in the current 15 minute interval. A BBE is an errored block not occurring as part of an SES.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslCurrentUASs 1.3.6.1.4.1.164.3.4.4.3.1.1.5
The number of Unavailable Seconds encountered by an HDSL interface in the current 15 minute interval. A UAS is any second in which a failed signal state exists. A failure state is declared when 10 consecutive SESs occur, and is cleared after 10 consecutive seconds free of an SES.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslCurrentNoiseMargin 1.3.6.1.4.1.164.3.4.4.3.1.1.6
The current noise margin in DB. This object is not an accumulative one, therefore it's value will appear only in this table.
OBJECT-TYPE    
  Integer32  

modmPrtHdslCurrentAttenuation 1.3.6.1.4.1.164.3.4.4.3.1.1.7
The current attenuation in DB. This object is not an accumulative one, therefore it's value will appear only in this table.
OBJECT-TYPE    
  Integer32  

modmPrtHdslIntervalTable 1.3.6.1.4.1.164.3.4.4.3.2
The HDSL Interval Table. The data collected is for the last 96 completed 15-minute intervals.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmPrtHdslIntervalEntry

modmPrtHdslIntervalEntry 1.3.6.1.4.1.164.3.4.4.3.2.1
An entry in the HDSL Interval Table. This entry is per an HDSL interface (LOOP1 or LOOP2) and per 15 minute interval. The port and unit (Central/Remote) is identified by its specific ifIndex value.
OBJECT-TYPE    
  ModmPrtHdslIntervalEntry  

modmPrtHdslIntervalNumber 1.3.6.1.4.1.164.3.4.4.3.2.1.1
The number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
OBJECT-TYPE    
  Integer32 1..96  

modmPrtHdslIntervalESs 1.3.6.1.4.1.164.3.4.4.3.2.1.2
The number of Errored Seconds encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslIntervalSESs 1.3.6.1.4.1.164.3.4.4.3.2.1.3
The number of Severely Errored Seconds encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslIntervalBBEs 1.3.6.1.4.1.164.3.4.4.3.2.1.4
The number of Background Block Errors encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslIntervalUASs 1.3.6.1.4.1.164.3.4.4.3.2.1.5
The number of Unavailable Seconds encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslIntervalESR 1.3.6.1.4.1.164.3.4.4.3.2.1.6
The ratio of ESs to 900 seconds, encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Integer32 0..100  

modmPrtHdslIntervalSESR 1.3.6.1.4.1.164.3.4.4.3.2.1.7
The ratio of SESs to 900 seconds, encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Integer32 0..100  

modmPrtHdslIntervalBBER 1.3.6.1.4.1.164.3.4.4.3.2.1.8
The ratio of BBEs to 900 seconds, encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Integer32 0..100  

modmPrtHdslTotalTable 1.3.6.1.4.1.164.3.4.4.3.3
The HDSL Total Table. The data collected is the cumulative sum of the various statistics for the 24 hour period preceding the current interval.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmPrtHdslTotalEntry

modmPrtHdslTotalEntry 1.3.6.1.4.1.164.3.4.4.3.3.1
An entry in the HDSL Total Table. This entry is per an HDSL interface (LOOP1 or LOOP2). The port and unit (Central/Remote) is identified by its specific ifIndex value.
OBJECT-TYPE    
  ModmPrtHdslTotalEntry  

modmPrtHdslTotalValidIntervals 1.3.6.1.4.1.164.3.4.4.3.3.1.1
The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought on-line within the last 24 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online.
OBJECT-TYPE    
  Integer32 0..96  

modmPrtHdslTotalESs 1.3.6.1.4.1.164.3.4.4.3.3.1.2
The number of Errored Seconds encountered by an HDSL interface in the previous 24 hour interval.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslTotalSESs 1.3.6.1.4.1.164.3.4.4.3.3.1.3
The number of Severely Errored Seconds encountered by an HDSL interface in the previous 24 hour interval.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslTotalBBEs 1.3.6.1.4.1.164.3.4.4.3.3.1.4
The number of Background Block Errors encountered by an HDSL interface in the previous 24 hour interval.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslTotalUASs 1.3.6.1.4.1.164.3.4.4.3.3.1.5
The number of Unavailable Seconds encountered by an HDSL interface in the previous 24 hour interval.
OBJECT-TYPE    
  Gauge32  

modmPrtHdslTable 1.3.6.1.4.1.164.3.4.4.3.4
The HDSL Table.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmPrtHdslEntry

modmPrtHdslEntry 1.3.6.1.4.1.164.3.4.4.3.4.1
An entry in the HDSL Table. The port and unit (Central/Remote) is identified by its specific modmPrtHdslIndex value.
OBJECT-TYPE    
  ModmPrtHdslEntry  

modmPrtHdslIndex 1.3.6.1.4.1.164.3.4.4.3.4.1.1
The HDSL port index. In some cases it can equal ifIndex.
OBJECT-TYPE    
  Integer32  

modmPrtHdslDedicatedTs 1.3.6.1.4.1.164.3.4.4.3.4.1.2
The HDSL Current Dedicated TS. Valid values: 0..31. 255 = None (no dedicated TS).
OBJECT-TYPE    
  Integer32 0..255  

modmPrtHdslPriorityBumping 1.3.6.1.4.1.164.3.4.4.3.4.1.3
The 4 bytes represent time slots 0..31 of the E1 frame. Each bit can be set to '1', making the corresponding time slot a HIGH priority. Bit 0 is always HIGH (cannot be modified by the user). The maximum number of HIGH priority time slots is: 16 for E1 ; 13 for T1 (including TS0). The default value is LOW, i.e., 0.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

modmPrtHdslMngProtocol 1.3.6.1.4.1.164.3.4.4.3.4.1.4
A unique number to identify an Inband management over the link.
OBJECT-TYPE    
  INTEGER off(2), dedicatedTs(4), dedicatedPpp(5), dedicatedFr(6)  

modmPrtHdslRoutProtocol 1.3.6.1.4.1.164.3.4.4.3.4.1.5
Inband Mng Routing Protocol of the port. When modmPrtHdslMngProtocol is 'dedicatedPpp'-'proprietary' and 'rip2' are applicable. For other values - only 'proprietary' is applicable.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

modmPrtHdslInbandMngRate 1.3.6.1.4.1.164.3.4.4.3.4.1.6
A unique number to identify the rate of the Inband management. It is applicable only when modmPrtHdslDedicatedTs <> (255 Or 0).
OBJECT-TYPE    
  INTEGER notApplicable(1), r4k(2), r8k(3), r12k(4), r16k(5), r32k(6), r64k(7)  

modmDtePort 1.3.6.1.4.1.164.3.4.4.4
OBJECT IDENTIFIER    

modmPrtDteTable 1.3.6.1.4.1.164.3.4.4.4.1
Configuration parameters of the Master and Slave Modem DTE Ports. The port and unit (Master/Slave) is identified by its specific modmPrtDteIndex value.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmPrtDteEntry

modmPrtDteEntry 1.3.6.1.4.1.164.3.4.4.4.1.1
An entry in table.
OBJECT-TYPE    
  ModmPrtDteEntry  

modmPrtDteIndex 1.3.6.1.4.1.164.3.4.4.4.1.1.1
The DTE port index.
OBJECT-TYPE    
  Integer32  

modmPrtDteProtocol 1.3.6.1.4.1.164.3.4.4.4.1.1.2
The DTE port Protocol.
OBJECT-TYPE    
  INTEGER sync(2), async(3)  

modmPrtDteDataBits 1.3.6.1.4.1.164.3.4.4.4.1.1.3
The DTE number of data bits.
OBJECT-TYPE    
  INTEGER dataBits6(1), dataBits7(2), dataBits8(3), dataBits9(4), dataBits10(5), dataBits11(6), dataBits5(7)  

modmPrtDteStopBits 1.3.6.1.4.1.164.3.4.4.4.1.1.4
The DTE minimum number of stop bits in the tx async frame.
OBJECT-TYPE    
  INTEGER stopBits1Bit(1), stopBits1dot5Bits(2), stopBits2Bits(3)  

modmPrtDteRate 1.3.6.1.4.1.164.3.4.4.4.1.1.5
The DTE port rate.
OBJECT-TYPE    
  INTEGER r300bps(1), r600bps(2), r1200bps(3), r2400bps(4), r4800bps(5), r9600bps(6), r14400bps(7), r16000bps(8), r19200bps(9), r28800bps(10), r32000bps(11), r38400bps(12), r48000bps(13), r56000bps(14), r57600bps(15), r64000bps(16), r72000bps(17), r96000bps(18), r112000bps(19), r115200bps(20), r128Kbps(21), r144Kbps(22), r192Kbps(23), r256Kbps(24), r320Kbps(25), r384Kbps(26), r448Kbps(27), r512Kbps(28), r576Kbps(29), r640Kbps(30), r704Kbps(31), r768Kbps(32), r1024Kbps(33), r1536Kbps(34), r1544Kbps(35), r2048Kbps(36), e1(37), t1(38), r896Kbps(39), r960Kbps(40), r1152Kbps(41), r1920Kbps(42), r34Mbps(43), r45Mbps(44), r1088Kbps(45), r1216Kbps(46), r1344Kbps(47), r1408Kbps(48), r1472Kbps(49), r1600Kbps(50), r1664Kbps(51), r1728Kbps(52), r1792Kbps(53), r1856Kbps(54), r1984Kbps(55), r1280Kbps(56), r2304Kbps(57), r832Kbps(58), r2176Kbps(59), r2432Kbps(60), r2560Kbps(61), r2688Kbps(62), r2816Kbps(63), r2944Kbps(64), r3072Kbps(65), r3200Kbps(66), r3328Kbps(67), r3456Kbps(68), r3584Kbps(69), r3712Kbps(70), r3840Kbps(71), r3968Kbps(72), r4096Kbps(73), r2112Kbps(74), r2240Kbps(75), r4224Kbps(76), r4352Kbps(77), r4480Kbps(78), r4608Kbps(79)  

modmPrtDteCtsDelay 1.3.6.1.4.1.164.3.4.4.4.1.1.6
CTS/RTS delay, in msec. dxx = xx msec. notApplicable - for ASMi-31, ASMi-32.
OBJECT-TYPE    
  INTEGER d0(1), d1(2), d7(3), d8(4), d10(5), d70(6), disabled(7), enabled(8), notApplicable(255)  

modmPrtDteParity 1.3.6.1.4.1.164.3.4.4.4.1.1.7
This attribute indicates the parity mode in async frame.
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3)  

modmPrtDteIfType 1.3.6.1.4.1.164.3.4.4.4.1.1.8
The interface type of the DTE port.
OBJECT-TYPE    
  INTEGER v24(1), rs530(2), x21(3), g703(4), v36(5), v35(6), g703r64k(7), hdb3(8), ethernet(9), g703T1(10), ethBNC(11), noIR(15), ipUtp(16), ethQ(17), rs530WA(18), v35WA(19), g704E1(20), ethQN(21), other(255)  

modmPrtDteRlbEnable 1.3.6.1.4.1.164.3.4.4.4.1.1.9
Enable/Disable Remote Loop-Back on this modem, externally initiated.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

modmPrtDteAlbEnable 1.3.6.1.4.1.164.3.4.4.4.1.1.10
Enable/Disable Analog Loop-Back on this modem, externally initiated.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

modmPrtDteRtsDcdEnable 1.3.6.1.4.1.164.3.4.4.4.1.1.11
Enable/Disable RTS-DCD.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

modmPrtDteDsrDtrEnable 1.3.6.1.4.1.164.3.4.4.4.1.1.12
Enable/Disable DSR-DTR.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

modmPrtDteSignaling 1.3.6.1.4.1.164.3.4.4.4.1.1.13
Each bit represents a specific signal state. 1 - means : signal is ON , Enabled, Yes (exists) 0 - means : signal is OFF, Disabled, No . For detailed bit assignment see product's spec.
OBJECT-TYPE    
  OCTET STRING  

modmPrtDteLoops 1.3.6.1.4.1.164.3.4.4.4.1.1.14
Loops that can be run on the DTE port. none - no loop (stop running loop) ana - Local Analog Line loop rem - Remote Analog Line loop anaAndBert - ana & BERT together remAndBert - rem & BERT together bert - BERT test twoBerts - 2 BERT test digital - A remote loop on the local modem. dual - Remote loop and ana loop. clb - Local loop on the DTE connection. Must be set together with modmPrtDteTestTimeOut parameter. Applicable to asmi51/CQ/CD. clbAndBert - CLB & BERT together. Applicable to asmi51/CQ/CD.
OBJECT-TYPE    
  INTEGER none(1), ana(2), rem(3), anaAndBert(4), remAndBert(5), bert(6), twoBerts(7), digital(8), dual(9), clb(10), clbAndBert(11)  

modmPrtDteTests 1.3.6.1.4.1.164.3.4.4.4.1.1.15
This is a mask which indicates - for Get: which tests are running on the DTE port. - for Set: tests the user wishes to start or stop. Each test has its specific bit. - '1' means the test runs (Set: should run). - '0' means the test does not run (Set: should stop): TEST BIT ----------- --- LEDs 0 e.g : If the return value is 1 the LEDs test is running.
OBJECT-TYPE    
  Integer32  

modmPrtDteClearAllTests 1.3.6.1.4.1.164.3.4.4.4.1.1.16
Setting this attribute to on, clears all the running loops and tests of the DTE port. Upon completion, the value will automatically change to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3)  

modmPrtDteBertResult 1.3.6.1.4.1.164.3.4.4.4.1.1.17
Result of BERT for the selected DTE port. Applicable only if BERT is running on the DTE port.
OBJECT-TYPE    
  DisplayString  

modmPrtDteErrCorrect 1.3.6.1.4.1.164.3.4.4.4.1.1.18
notApplicable - for modems that do not support this object on - will start a random error correction process. onBurst - will start a burst error correction process. Setting this object to 'off', will stop any kind of error correction process.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3), onBurst(4)  

modmPrtDteV54DigitalTest 1.3.6.1.4.1.164.3.4.4.4.1.1.19
Enables to start a remote digital loopback upon recognition of a special pattern. disable - will not start a digital loopback when a special pattern is recognized. enable - will start a loopback upon recognition of a special pattern.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

modmPrtDteV54DigitalTestStatus 1.3.6.1.4.1.164.3.4.4.4.1.1.20
Indicates whether a remote digital test was triggered by a pattern by the remote modem or not. no - the digital test wasn't triggered by a pattern by the remote modem. yes - the digital test was triggered by a pattern by the remote modem.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

modmPrtDteTestTimeOut 1.3.6.1.4.1.164.3.4.4.4.1.1.21
Indicates the timeout for LLB test. 0=Forever
OBJECT-TYPE    
  Integer32  

modmLinePort 1.3.6.1.4.1.164.3.4.4.5
OBJECT IDENTIFIER    

modmPrtLineTable 1.3.6.1.4.1.164.3.4.4.5.1
Configuration parameters of the Master and Slave Modem Line Ports. The port and unit (Master/Slave) is identified by its specific modmPrtLineIndex value.
OBJECT-TYPE    
  SEQUENCE OF  
    ModmPrtLineEntry

modmPrtLineEntry 1.3.6.1.4.1.164.3.4.4.5.1.1
An entry in table.
OBJECT-TYPE    
  ModmPrtLineEntry  

modmPrtLineIndex 1.3.6.1.4.1.164.3.4.4.5.1.1.1
The Line port index.
OBJECT-TYPE    
  Integer32  

modmPrtLineClkSrc 1.3.6.1.4.1.164.3.4.4.5.1.1.2
The clock source of the Line port. (5),(6) - applicable only for ASMi-24 and ASMi-50. (7),(8) - System level Clock Source. Applicable to CQ modems.
OBJECT-TYPE    
  INTEGER localExtRemoteRcv(1), localIntRemoteRcv(2), localRcvRemoteInt(3), localRcvRemoteExt(4), localExtAutoRemoteRcv(5), localRcvRemoteExtAuto(6), localSysRemoteRcv(7), localRcvRemoteSys(8), internal(9), external(10), system(11), receive(12), notApplicable(255)  

modmPrtLineTxLevel 1.3.6.1.4.1.164.3.4.4.5.1.1.3
Transmit level in dBm. pxx = positive xx = +xx nxx = negative xx = -xx
OBJECT-TYPE    
  INTEGER n12(1), n9(2), n6(3), n3(4), p0(5), p4(6), p6(7), p10(8)  

modmPrtLineRxLevel 1.3.6.1.4.1.164.3.4.4.5.1.1.4
Rx Sensitivity in dBm. pxx = positive xx = +xx nxx = negative xx = -xx.
OBJECT-TYPE    
  INTEGER n14(1), n12(2), n10(3), n9(4), n6(5), n3(6), p0(7), low(8), high(9)  

modmPrtLineOutImp 1.3.6.1.4.1.164.3.4.4.5.1.1.5
Output impedance in Ohm.
OBJECT-TYPE    
  INTEGER infinite(1), i75ohm(2), i100ohm(3), i120ohm(4), i150ohm(5), i300ohm(6), i600ohm(7)  

modmPrtLineInImp 1.3.6.1.4.1.164.3.4.4.5.1.1.6
Input impedance in Ohm.
OBJECT-TYPE    
  INTEGER infinite(1), i75ohm(2), i100ohm(3), i120ohm(4), i150ohm(5), i300ohm(6), i600ohm(7)  

modmPrtLineCarrCntrl 1.3.6.1.4.1.164.3.4.4.5.1.1.7
Carrier control.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

modmPrtLineRAP 1.3.6.1.4.1.164.3.4.4.5.1.1.8
Rate Adapting Protocol.
OBJECT-TYPE    
  INTEGER private(1), v110(2), v220(3), notApplicable(255)  

modmPrtLineWaveLength 1.3.6.1.4.1.164.3.4.4.5.1.1.9
Wave Length of the optical Line. notApplicable - when the modem Line is not optical. The units are nano-meters [nm].
OBJECT-TYPE    
  INTEGER notApplicable(1), nm850(2), nm1300(3), nm780Laser(4), nm1300Laser(5), nm1550Laser(6)  

modmPrtLineCdSense 1.3.6.1.4.1.164.3.4.4.5.1.1.10
Carrier Detect Sense - Detection Sensitivity of Carrier Wave. high - high sensitivity low - low sensitivity.
OBJECT-TYPE    
  INTEGER notApplicable(1), high(2), low(3)  

modmPrtLineAIS 1.3.6.1.4.1.164.3.4.4.5.1.1.11
AIS enable/disable. notApplicable - for modems that do not support this feature.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

modmPrtLineCoding 1.3.6.1.4.1.164.3.4.4.5.1.1.12
Line Coding.
OBJECT-TYPE    
  INTEGER notApplicable(1), ami(2), hdb3(3), b8zs(4)  

modmPrtLineLength 1.3.6.1.4.1.164.3.4.4.5.1.1.13
This attribute is the line length mask parameter used only for T1/DSU interfaces. len400p533ft=length range: 400ft to 533ft.
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), notApplicable(255)  

modmPrtLineClkSrcPort 1.3.6.1.4.1.164.3.4.4.5.1.1.14
Clock Source Port. This parameter is relevant for external clock source.
OBJECT-TYPE    
  INTEGER notApplicable(1), modem1(2), modem2(3), modem3(4), modem4(5)  

modmPrtLineDteClkConfig 1.3.6.1.4.1.164.3.4.4.5.1.1.15
Indicates the clock source of the modems, which were not selected to supply the external clock.
OBJECT-TYPE    
  INTEGER notApplicable(1), dceExternal(2), dce(3)  

modmPrtLineMaskAlr 1.3.6.1.4.1.164.3.4.4.5.1.1.16
This parameter determine whether masking or not the alarms for this line.
OBJECT-TYPE    
  INTEGER notApplicable(1), dontMask(2), mask(3)  

kmux 1.3.6.1.4.1.164.3.6
OBJECT IDENTIFIER    

systemKmux 1.3.6.1.4.1.164.3.6.1
OBJECT IDENTIFIER    

generalKmux 1.3.6.1.4.1.164.3.6.1.1
OBJECT IDENTIFIER    

sysGenKmuxTable 1.3.6.1.4.1.164.3.6.1.1.1
A table containing the general Kmux parameters.
OBJECT-TYPE    
  SEQUENCE OF  
    SysGenKmuxEntry

sysGenKmuxEntry 1.3.6.1.4.1.164.3.6.1.1.1.1
An entry in table.
OBJECT-TYPE    
  SysGenKmuxEntry  

sysGenConfigIdx 1.3.6.1.4.1.164.3.6.1.1.1.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). The write operation in this Table is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  Integer32 1..255  

sysGenFlipIntegration 1.3.6.1.4.1.164.3.6.1.1.1.1.2
The parameter is relevant only for KM-2100 and only when sysGenMlMode=redundancy, switchBackup, or priorityBumping.
OBJECT-TYPE    
  INTEGER notApplicable(1), short(2), long(3)  

sysGenMlMode 1.3.6.1.4.1.164.3.6.1.1.1.1.3
The Main Link operation mode. Determines how many links are used (one/two) and how they are used.
OBJECT-TYPE    
  INTEGER single(2), redundancy(3), dualLink(4), priorityBumping(5), switchBackup(6)  

sysGenFaType 1.3.6.1.4.1.164.3.6.1.1.1.1.4
Frame Allocation type: auto - automatic frame allocation (by Kmux) manual - manually configured frame allocation (by user).
OBJECT-TYPE    
  INTEGER auto(2), manual(3)  

sysGenLinkRecovery 1.3.6.1.4.1.164.3.6.1.1.1.1.5
The parameter determines the Link Recovery mode. The parameter is relevant only when the sysGenMlMode is either switchBackup or priorityBumping.
OBJECT-TYPE    
  INTEGER notApplicable(1), auto(2), manual(3)  

sysGenLinkSourceClock 1.3.6.1.4.1.164.3.6.1.1.1.1.6
The source clock for the links. The parameter is relevant only for KM-2100 having a KDI or KDI/CH cards. ML-A or ML-B are selectable only when sysGenMlMode=dual or priorityBumping.
OBJECT-TYPE    
  INTEGER none(1), kmxMlA(103), kmxMlB(104)  

sysGenMngBwA 1.3.6.1.4.1.164.3.6.1.1.1.1.7
The required management rate for ML-A, in bps. It is very important when a remote unit is managed. The selected value must be < ML-A Rate value. 0 = None or not applicable 800 bps = minimum value 19200 bps = maximum value
OBJECT-TYPE    
  Integer32  

sysGenMngBwB 1.3.6.1.4.1.164.3.6.1.1.1.1.8
The required management rate for ML-B, in bps. It is very important when a remote unit is managed. The selected value must be < ML-B Rate value. 0 = None or not applicable 800 bps = minimum value 19200 bps = maximum value
OBJECT-TYPE    
  Integer32  

sysGenAutoDialSlot 1.3.6.1.4.1.164.3.6.1.1.1.1.9
This object indicates the IO-SLOTs that can be used to initiate Automatic DialUp. This field will be applicable when KML.10 is a ML and its prtIsdnSwitchMode=auto. Each IO Slot is represented by a bit: 11 .............0 MSB(IO12) LSB(IO1) bit 0 (LSB) kmxIO1: '1'- used '0'- not used bit 1 kmxIO2: '1'- used '0'- not used bit 2 kmxIO3: '1'- used . '0'- not used . bit 11(MSB) kmxIO12: '1'- used '0'- not used The value will be: SUM of [2**n] ; n=bit number.
OBJECT-TYPE    
  Integer32  

sysGenResetBypassEnable 1.3.6.1.4.1.164.3.6.1.1.1.1.10
Enable/Disable Reset Bypass operation when a KDI card exists and one of its links failed. notApplicable - when no KDI card exists in the Hub.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

sysGenLinkRecoveryCmd 1.3.6.1.4.1.164.3.6.1.1.2
Command to recover from ML failure. When 'on', the agent will perform manual link recovery and reset the variable to 'off'. The conditions for this action are: sysGenMlMode= priorityBumping or switchBackup and also sysGenLinkRecovery=manual(3).
OBJECT-TYPE    
  INTEGER noOp(1), off(2), on(3)  

sysGenFlipMlCmd 1.3.6.1.4.1.164.3.6.1.1.3
Command to flip the ML when sysGenMlMode=redundancy. When 'on', the agent will flip the ML and reset the variable to 'off'.
OBJECT-TYPE    
  INTEGER noOp(1), off(2), on(3)  

sysGenMonitorChannel 1.3.6.1.4.1.164.3.6.1.1.4
The variable specifies the channel to be monitored and presented on the front panel LEDs. The channel will be specified according to: Slot*100+Ch. 0 - no monitoring.
OBJECT-TYPE    
  Integer32  

statusKmux 1.3.6.1.4.1.164.3.6.1.2
OBJECT IDENTIFIER    

sysStatusOnLineML 1.3.6.1.4.1.164.3.6.1.2.1
The main links which are online.
OBJECT-TYPE    
  INTEGER both(1), kmxMlA(103), kmxMlB(104)  

sysKmuxStatus 1.3.6.1.4.1.164.3.6.1.2.2
A BIT string indicating the system status as follows On - the bit is set to '1': Bit 0 (LSB): Alarm Relay. Bit 1: SP param. Off- Configure the SP port from the database On - Default parameters (9600bps, 8 data bits, no parity, one stop bit). Bit 2: DBinit. The status of the dip switch in the Common Logic Card. Off- Configuration parameters were determined by the user. On - Default configuration parameters are loaded on mux power-on. Bit 3: DownloadBw. Off - Disable in-band management. On - Enable in-band management. Bit 4 (MSB): Passwd. Off - No password is required. On - Password is required. Example: 8 (10000) means Passwd.=On and all the others off.
OBJECT-TYPE    
  Integer32  

sysKmuxOffset 1.3.6.1.4.1.164.3.6.1.2.3
'on' - slots 1..4 of KM-2104 match slots 11..14 of KM-2100. 'off'- slots 1..4 of KM-2104 match slots 7..10 of KM-2100. notApplicable - for KM-2100.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

backupKmux 1.3.6.1.4.1.164.3.6.1.3
OBJECT IDENTIFIER    

sysBackupTable 1.3.6.1.4.1.164.3.6.1.3.1
A table containing the backup parameters.
OBJECT-TYPE    
  SEQUENCE OF  
    SysBackupEntry

sysBackupEntry 1.3.6.1.4.1.164.3.6.1.3.1.1
An entry in table.
OBJECT-TYPE    
  SysBackupEntry  

sysBackupConfigIdx 1.3.6.1.4.1.164.3.6.1.3.1.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch).
OBJECT-TYPE    
  Integer32 1..255  

sysBackupDatabase 1.3.6.1.4.1.164.3.6.1.3.1.1.2
Determines the database to switch to, when ML recovery occurs.
OBJECT-TYPE    
  INTEGER onLine(2), alternate(3)  

sysBackupMode 1.3.6.1.4.1.164.3.6.1.3.1.1.3
isdn - for connection to ISDN network. pstn - for connection to PSTN network.
OBJECT-TYPE    
  INTEGER isdn(2), pstn(3)  

sysBackupDialTimeout 1.3.6.1.4.1.164.3.6.1.3.1.1.4
The dial timeout in seconds (when backup is attempted).
OBJECT-TYPE    
  INTEGER sec30(2), sec45(3), sec60(4), sec120(5)  

sysBackupOptions 1.3.6.1.4.1.164.3.6.1.3.1.1.5
The Backup options: noBackup - No backup is applicable line - Line Data backup path - Line Mng backup .
OBJECT-TYPE    
  INTEGER noBackup(2), line(3), path(4)  

sysBackupAgendaTable 1.3.6.1.4.1.164.3.6.1.3.2
A table containing the backup schedule. It is possible to define 4 different time zone schedules per day of the week.
OBJECT-TYPE    
  SEQUENCE OF  
    SysBackupAgendaEntry

sysBackupAgendaEntry 1.3.6.1.4.1.164.3.6.1.3.2.1
An entry in table.
OBJECT-TYPE    
  SysBackupAgendaEntry  

sysBackupCfgIdx 1.3.6.1.4.1.164.3.6.1.3.2.1.1
This object indicates the Configuration number (1,255) referred. Write operation for the table entries is allowed only to the temporary configuration (255).
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

sysBackupDay 1.3.6.1.4.1.164.3.6.1.3.2.1.2
Day of the week.
OBJECT-TYPE    
  INTEGER sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7)  

sysBackupZone 1.3.6.1.4.1.164.3.6.1.3.2.1.3
The time zone.
OBJECT-TYPE    
  INTEGER zone1(1), zone2(2), zone3(3), zone4(4), zone5(5)  

sysBackupEndTime 1.3.6.1.4.1.164.3.6.1.3.2.1.4
The end time for this time zone. The format is HH:MM. For example 23:59. For Zone 4, End Time = 23:59 (constant).
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

sysBackupStatus 1.3.6.1.4.1.164.3.6.1.3.2.1.5
Enable or disable this backup schedule entry.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

frameAllocationKmux 1.3.6.1.4.1.164.3.6.1.4
OBJECT IDENTIFIER    

sysFrameAllocationTable 1.3.6.1.4.1.164.3.6.1.4.1
A table for manually configuring the frame allocation. The table will contain always all the programmed cards' ports. sysFaNumOfBits
OBJECT-TYPE    
  SEQUENCE OF  
    SysFrameAllocationEntry

sysFrameAllocationEntry 1.3.6.1.4.1.164.3.6.1.4.1.1
An entry in table.
OBJECT-TYPE    
  SysFrameAllocationEntry  

sysFaConfigIdx 1.3.6.1.4.1.164.3.6.1.4.1.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). Write operation for the table entries is allowed only to Config=255.
OBJECT-TYPE    
  Integer32 1..255  


sysFaPrt 1.3.6.1.4.1.164.3.6.1.4.1.1.3
The Frame Allocation (FA) port. The ports will be specified by: Slot*100+Ch. - for Bypass of KDI or KDI/CH the port will be: Slot*100+11 (internal-1=non-existent port ; just for use of the same MIB table) - for all the programmed cards, there will be an artificial port entry that will represent the card, in order to specify the Control Signal Bits that are at card level: Slot*100+0 .
OBJECT-TYPE    
  Integer32  

sysFaStartingBit 1.3.6.1.4.1.164.3.6.1.4.1.1.4
The data starting bit for the channel. - for Bypass of KDI or KDI/CH, this will be the Starting Bit of the Bypass Window on the specific sysFaLink. - for Control Signals of a card ( sysFaPrt=Slot*100+0) this will be the Starting Bit of the Control Signals of the card.
OBJECT-TYPE    
  Integer32 0..239  

sysFaNumOfBits 1.3.6.1.4.1.164.3.6.1.4.1.1.5
The data size in number of bits for the channel. - for Bypass of KDI or KDI/CH, this will be the Bypass Window size. In this case, this value must be the same for both MLs. - for Control Signals of a card ( sysFaPrt=Slot*100+0) this will be the number of Control Signal Bits of the card.
OBJECT-TYPE    
  Integer32 0..239  

sysDisconnectSupervisionEventTable 1.3.6.1.4.1.164.3.6.1.5
Disconnect Supervision Event table.
OBJECT-TYPE    
  SEQUENCE OF  
    SysDisconnectSupervisionEventEntry

sysDisconnectSupervisionEventEntry 1.3.6.1.4.1.164.3.6.1.5.1
An entry in the table.
OBJECT-TYPE    
  SysDisconnectSupervisionEventEntry  

sysDsEventIdx 1.3.6.1.4.1.164.3.6.1.5.1.1
This object indicates a unique Event Index.
OBJECT-TYPE    
  Integer32  

sysDsEventSlot 1.3.6.1.4.1.164.3.6.1.5.1.2
This object indicates a unique number of the slot position, where the KVF.6 or KVF.8 card is inserted, and the Disconnect Supervision Event occurred.
OBJECT-TYPE    
  INTEGER kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

sysDsEventTS 1.3.6.1.4.1.164.3.6.1.5.1.3
This object defines the Time Slot number, where the Disconnect Supervision Event occurred.
OBJECT-TYPE    
  Integer32 1..31  

sysDsEventDescr 1.3.6.1.4.1.164.3.6.1.5.1.4
This object defines the Description of the Disconnect Supervision Event.
OBJECT-TYPE    
  DisplayString  

sysDsEventDateAndTime 1.3.6.1.4.1.164.3.6.1.5.1.5
This object defines the Date and Time, when the Disconnect Supervision Event occurred. It will be displayed in the following format: YYYY-MM-DD HH:MM:SS.
OBJECT-TYPE    
  DisplayString  

mdlKmux 1.3.6.1.4.1.164.3.6.2
OBJECT IDENTIFIER    

mdlKmxTable 1.3.6.1.4.1.164.3.6.2.2
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlKmxEntry

mdlKmxEntry 1.3.6.1.4.1.164.3.6.2.2.1
An entry in table.
OBJECT-TYPE    
  MdlKmxEntry  

mdlKmxConfigIdx 1.3.6.1.4.1.164.3.6.2.2.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). Write operation for the table entries is allowed only to Config=255.
OBJECT-TYPE    
  Integer32 1..255  

mdlKmxSlotIdx 1.3.6.1.4.1.164.3.6.2.2.1.2
This object indicates a unique number of the slot position in which the module is inserted.
OBJECT-TYPE    
  INTEGER kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlKmxOperatedMl 1.3.6.1.4.1.164.3.6.2.2.1.3
The main link for this card. The field is relevant only for ML modes of Dual, Priority Bumping and Switched Backup.
OBJECT-TYPE    
  INTEGER notApplicable(1), kmxMlA(103), kmxMlB(104), kmxMlAandMlB(119)  

mdlKmxMlAtoMlBPrio 1.3.6.1.4.1.164.3.6.2.2.1.4
ML-A to ML-B Priority. The field is relevant only for ML modes of Priority Bumping and Switched Backup.
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

mdlKmxMlBtoMlAPrio 1.3.6.1.4.1.164.3.6.2.2.1.5
ML-B to ML-A Priority. The field is relevant only for ML modes of Priority Bumping.
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

mdlKmxOutSrvMethod 1.3.6.1.4.1.164.3.6.2.2.1.6
Out of service method. For KVC.1 and KVC.1M all values are applicable. For KVC.2, KVC.3, KVF.1, KVF.3, KVF.4: only forcedIdle and forcedBusy are applicable.
OBJECT-TYPE    
  INTEGER notApplicable(1), idleBusy(2), forcedIdle(3), busyIdle(4), forcedBusy(5)  

mdlKmxV54Config 1.3.6.1.4.1.164.3.6.2.2.1.7
Relevant only for KLS.1/New card.
OBJECT-TYPE    
  INTEGER notApplicable(1), dceDce(2), dceDte(3), dteDce(4), dteDte(5)  

mdlKmxTiming 1.3.6.1.4.1.164.3.6.2.2.1.8
Applicable only for KHSU.1, KHSU.2, KVF.4/S0, KVC.3/S0 cards. lt - local timing nt - network timing te - terminal equipment
OBJECT-TYPE    
  INTEGER notApplicable(1), lt(2), nt(3), te(4)  

mdlKvf5PbxTable 1.3.6.1.4.1.164.3.6.2.3
Parameters specific to KVF.5, KVF.6 and KVF.8 PBX cards.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlKvf5PbxEntry

mdlKvf5PbxEntry 1.3.6.1.4.1.164.3.6.2.3.1
An entry in table.
OBJECT-TYPE    
  MdlKvf5PbxEntry  

mdlKvf5PbxConfigIdx 1.3.6.1.4.1.164.3.6.2.3.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). Write operation for the table entries is allowed only to Config=255.
OBJECT-TYPE    
  Integer32 1..255  

mdlKvf5PbxSlotIdx 1.3.6.1.4.1.164.3.6.2.3.1.2
This object indicates a unique number of the slot position in which the module is inserted.
OBJECT-TYPE    
  INTEGER kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlKvf5PbxSig 1.3.6.1.4.1.164.3.6.2.3.1.3
Signaling type. When 'mdlKvf5PbxSig' is valid, 'mdlKvf5PbxSigTxPbx' and 'mdlKvf5PbxSigRxPbx' are not valid. mdlKvf5PbxSig - is supported by KVF.5 OLD SW ver and KVF.6 card. mdlKvf5PbxSigTxPbx and mdlKvf5PbxSigRxPbx - are supported by KVF.5 NEW SW ver and KVF.6.
OBJECT-TYPE    
  INTEGER notApplicable(1), a(2), aANDb(3), b(4), ccs(5), cas(6)  

mdlKvf5PbxSigMode 1.3.6.1.4.1.164.3.6.2.3.1.4
Signaling Mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), direct(2), inverse(3)  

mdlKvf5PbxTsAssign 1.3.6.1.4.1.164.3.6.2.3.1.5
Ts Assignment group. Each KVF.5 card of the Mux should have a different value. For KVF.5/E1 values: 2,3,4,8,9,10,11,12 are applicable. For KVF.5/T1 values: 2,3,4,5,6,7 are applicable.
OBJECT-TYPE    
  INTEGER s1s2s3s4(2), s5s6s7s8(3), s9s10s11s12(4), s13s14s15s16(5), s17s18s19s20(6), s21s22s23s24(7), s13s14s15s17(8), s18s19s20s21(9), s22s23s24s25(10), s26s27s28s29(11), s30s31(12)  

mdlKvf5PbxCcsTs 1.3.6.1.4.1.164.3.6.2.3.1.6
CCS TS of the KVF.5/T1/E1 and KVF.6/T1/E1 card. It is applicable for Kmux KVF.5 Framer cards and KVF.6 cards when mdlKvf5PbxSig=ccs. Valid values: 1..24 - CCS TS of T1 1..31 - CCS TS of E1 255 - notApplicable (for agents that do not support this feature or for irrelevant cards) Other values are invalid. The value selected should not be the same as one of the TSs assigned for any card of the same group via mdlKvf5PbxTsAssign.
OBJECT-TYPE    
  Integer32  

mdlKvf5PbxOos 1.3.6.1.4.1.164.3.6.2.3.1.7
'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0
OBJECT-TYPE    
  INTEGER notSupported(2), forcedIdle(3), forcedBusy(4)  

mdlKvf5PbxSigTxPbx 1.3.6.1.4.1.164.3.6.2.3.1.8
TxPbx signaling means transmit signaling from KM to PBX (KM-->PBX) When 'mdlKvf5PbxSigTxPbx' is valid, 'mdlKvf5PbxSig' field is not valid. mdlKvf5PbxSig - is supported by KVF.5 OLD SW ver. mdlKvf5PbxSigTxPbx and mdlKvf5PbxSigRxPbx - are supported by KVF.5 NEW SW ver.
OBJECT-TYPE    
  INTEGER notApplicable(1), a(2), b(3), aANDb(4), crossAandB(5), ccs(6), aEqualsB(7)  

mdlKvf5PbxSigRxPbx 1.3.6.1.4.1.164.3.6.2.3.1.9
RxPbx signaling means receive signaling from PBX to KM (PBX-->KM-->KM) When 'mdlKvf5PbxSigRxPbx' is valid, 'mdlKvf5PbxSig' field is not valid. mdlKvf5PbxSig - is supported by KVF.5 OLD SW ver. mdlKvf5PbxSigTxPbx and mdlKvf5PbxSigRxPbx - are supported by KVF.5 NEW SW ver.
OBJECT-TYPE    
  INTEGER notApplicable(1), a(2), b(3), aANDb(4), ccs(6)  

mdlKvf5PbxDefABCD 1.3.6.1.4.1.164.3.6.2.3.1.10
This object determines what KM will send for the ABCD Bits that are not 'filled' by the dynamic signaling. This field is applicable only for signaling transmit to PBX ('mdlKvf5PbxSigTxPbx'). For KVF.5 cards: valid range (00 - 0F HEX) - ABCD Bits.
OBJECT-TYPE    
  OCTET STRING SIZE(0..1)  

mdlKvf5PbxFramerSlot 1.3.6.1.4.1.164.3.6.2.3.1.11
This object indicates the Framer's slot number this card belongs to. Several cards having the same mdlKvf5PbxFramerSlot value, work together as a group.
OBJECT-TYPE    
  INTEGER kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable(255)  

mdlKvf5PbxCcsRate 1.3.6.1.4.1.164.3.6.2.3.1.12
Determines the Ccs speed - for KVF.6 and KVF.5 cards.
OBJECT-TYPE    
  INTEGER notConnected(1), bps4800(2), bps6400(3), bps9600(4), bps12800(5), bps16000(6), bps19200(7), bps32000(8), bps64000(9)  

mdlKvf5PbxTxAbcdBit 1.3.6.1.4.1.164.3.6.2.3.1.13
This object is applicable only for KVF.6 and KVF.8 cards, when mdlKvf5PbxSig=cas(6). It represents 4 parameters, by 2 Octets : D Bit Code-MSB nibble, C Bit Code- nibble, B Bit Code- nibble, A Bit Code-LSB nibble. Each of A,B,C,D Bit Code nibble represents: 0 hex = 0000 = 0 1 hex = 0001 = 1 2 hex = 0010 = A bit 3 hex = 0011 = B bit 4 hex = 0100 = C bit 5 hex = 0101 = D bit 6 hex = 0110 = A bit inverse 7 hex = 0111 = B bit inverse 8 hex = 1000 = C bit inverse 9 hex = 1001 = D bit inverse A-E hex - not used (invalid values) When the object is not applicable, 0 Octets will be sent.
OBJECT-TYPE    
  OCTET STRING  

mdlKvf5PbxHdlcCrc 1.3.6.1.4.1.164.3.6.2.3.1.14
Determines the CRC type of HDLC protocol, that CCS signaling is working with. Applicable for KVF.6 cards when Signaling is CCS (only).
OBJECT-TYPE    
  INTEGER notApplicable(1), crc16(2), crc32(3)  

mdlDisconnectSupervisionTable 1.3.6.1.4.1.164.3.6.2.4
Disconnect Supervision table.
OBJECT-TYPE    
  SEQUENCE OF  
    MdlDisconnectSupervisionEntry

mdlDisconnectSupervisionEntry 1.3.6.1.4.1.164.3.6.2.4.1
An entry in the table.
OBJECT-TYPE    
  MdlDisconnectSupervisionEntry  

mdlDsConfigIdx 1.3.6.1.4.1.164.3.6.2.4.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). Write operation for the table entries is allowed only to Config=255.
OBJECT-TYPE    
  Integer32 1..255  

mdlDsSlotIdx 1.3.6.1.4.1.164.3.6.2.4.1.2
This object indicates a unique number of the slot position in which the module is inserted.
OBJECT-TYPE    
  INTEGER kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlDs 1.3.6.1.4.1.164.3.6.2.4.1.3
This object defines which terms will cause disconnection of call. disable = the Disconnect Supervision feature is disabled. In this case, all other objects of this table are irrelevant. Remote Sanity - If mdlDsUserLoc = Remote Location , the valid values are : disable(1), silenceOnly(4), fastBusyOnly(5), silenceOrFastBusy(6). If mdlDsUserLoc = Local , the valid values are disable(1), remoteDisconnect(2), remoteDisconnectAndSilence (3).
OBJECT-TYPE    
  INTEGER disable(1), remoteDisconnect(2), remoteDisconnectAndSilence(3), silenceOnly(4), fastBusyOnly(5), silenceOrFastBusy(6)  

mdlDsUserLoc 1.3.6.1.4.1.164.3.6.2.4.1.4
User located in local or remote station. Local station will disconnect the call actually if needed. Applicable only if Disconnect Supervision (mdlDs) is different from disable. Should be a Sanity check between the mdlDs and the mdlDsUserLoc parameters (see mdlDs).
OBJECT-TYPE    
  INTEGER notApplicable(1), remote(2), local(3)  

mdlDsMode 1.3.6.1.4.1.164.3.6.2.4.1.5
This object defines the action, which will be done after remote disconnect occurred. This object is relevant only when mdlDsUserLoc = local(3). Applicable only if Disconnect Supervision (mdlDs) is different from disable AND User Location (mdlDsUserLoc) = local(3).
OBJECT-TYPE    
  INTEGER notApplicable(1), reportOnly(2), disconnect(3)  

mdlDsSilence 1.3.6.1.4.1.164.3.6.2.4.1.6
This object defines the silence period needed for an indication (seconds). Applicable only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Silence', i.e. is one of the following: remoteDisconnectAndSilence(3), silenceOnly(4), silenceOrFastBusy(6). Valid values: 0,20,40..(every 20 seconds)..300, 0 = notApplicable. notApplicable = silence disabled when mdlDs doesn't include 'silence'.
OBJECT-TYPE    
  Integer32  

mdlDsClrFwSig 1.3.6.1.4.1.164.3.6.2.4.1.7
This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards. This object is an indication of Near PBX to the Far PBX, that it wants to disconnect the call. Applicable only if Disconnect Supervision (mdlDs) is different from disable. Applicable only for KVF.6 cards. It represents 4 parameters, by an Octet: ( Bit 7 = MSB, Bit 0 = LSB ) D Bit - bits 6,7 of the MSB nibble, C Bit - bits 4,5 of the MSB nibble, B Bit - bits 2,3 of the LSB nibble, A Bit - bits 0,1 of the LSB nibble. For each of A,B,C,D Bits: 00 = 0, 01 = 1, 10 = reserved, 11 = x. For A,B Bits - only one of them can be 'x' (not both at the same time). For C,D Bits - 'x' won't be in use. When the object is not applicable, a 0 Octet will be sent.
OBJECT-TYPE    
  OCTET STRING  

mdlDsAnswerSig 1.3.6.1.4.1.164.3.6.2.4.1.8
This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards. This object is an indication of Near PBX to the Far PBX, taht a call is present now on the line. Applicable only if Disconnect Supervision (mdlDs) is different from disable. Applicable only for KVF.6 cards. It represents 4 parameters, by an Octet: ( Bit 7 = MSB, Bit 0 = LSB ) D Bit - bits 6,7 of the MSB nibble, C Bit - bits 4,5 of the MSB nibble, B Bit - bits 2,3 of the LSB nibble, A Bit - bits 0,1 of the LSB nibble. For each of A,B,C,D Bits: 00 = 0, 01 = 1, 10 = reserved, 11 = x. For A,B Bits - only one of them can be 'x' (not both at the same time). For C,D Bits - 'x' won't be in use. When the object is not applicable, a 0 Octet will be sent.
OBJECT-TYPE    
  OCTET STRING  

mdlDsClrBwSig 1.3.6.1.4.1.164.3.6.2.4.1.9
This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards. This object is an indication of Far PBX to the Near PBX, that the call was disconnected (on the Far side). Applicable only if Disconnect Supervision (mdlDs) is different from disable. Applicable only for KVF.6 cards. It represents 4 parameters, by an Octet: ( Bit 7 = MSB, Bit 0 = LSB ) D Bit - bits 6,7 of the MSB nibble, C Bit - bits 4,5 of the MSB nibble, B Bit - bits 2,3 of the LSB nibble, A Bit - bits 0,1 of the LSB nibble. For each of A,B,C,D Bits: 00 = 0, 01 = 1, 10 = reserved, 11 = x. For A,B,C,D Bits - 'x' won't be in use. When the object is not applicable, a 0 Octet will be sent.
OBJECT-TYPE    
  OCTET STRING  

mdlDsFbtLowFreq 1.3.6.1.4.1.164.3.6.2.4.1.10
First frequency in Fast Busy Tone (Fbt) combination (Hz). Valid values: 0..4000,4095. 4095 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6).
OBJECT-TYPE    
  Integer32  

mdlDsFbtHighFreq 1.3.6.1.4.1.164.3.6.2.4.1.11
Second frequency in Fast Busy Tone (Fbt) combination (Hz). Valid values: 0..4000,4095. 4095 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6).
OBJECT-TYPE    
  Integer32  

mdlDsFbtTimeOn1 1.3.6.1.4.1.164.3.6.2.4.1.12
This object defines the Time On 1 cadence (in msec). Valid values: 0,10,20..(every 10 msec)..10000,10230. 0 = disable, 10230 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6).
OBJECT-TYPE    
  Integer32  

mdlDsFbtTimeOff1 1.3.6.1.4.1.164.3.6.2.4.1.13
This object defines the Time Off 1 cadence (in msec). Valid values: 0,10,20..(every 10 msec)..10000,10230. 0 = disable, 10230 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6).
OBJECT-TYPE    
  Integer32  

mdlDsFbtTimeOn2 1.3.6.1.4.1.164.3.6.2.4.1.14
This object defines the Time On 2 cadence (in msec). Valid values: 0,10,20..(every 10 msec)..10000,10230. 0 = disable, 10230 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6).
OBJECT-TYPE    
  Integer32  

mdlDsFbtTimeOff2 1.3.6.1.4.1.164.3.6.2.4.1.15
This object defines the Time Off 2 cadence (in msec). Valid values: 0,10,20..(every 10 msec)..10000,10230. 0 = disable, 10230 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6).
OBJECT-TYPE    
  Integer32  

mdlDsFbtLowFreqLevel 1.3.6.1.4.1.164.3.6.2.4.1.16
First frequency level for Fast Busy Tone (Fbt) in dBm units. Valid values: -32..31. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6).
OBJECT-TYPE    
  Integer32  

mdlDsFbtHighFreqLevel 1.3.6.1.4.1.164.3.6.2.4.1.17
Second frequency level for Fast Busy Tone (Fbt) in dBm units. Valid values: -32..31. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6).
OBJECT-TYPE    
  Integer32  

prtKmux 1.3.6.1.4.1.164.3.6.3
OBJECT IDENTIFIER    


prtMlFrameStatsTable 1.3.6.1.4.1.164.3.6.3.1.1
Frame diagnostics for the main links.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtMlFrameStatsEntry

prtMlFrameStatsEntry 1.3.6.1.4.1.164.3.6.3.1.1.1
An entry in table.
OBJECT-TYPE    
  PrtMlFrameStatsEntry  

prtMlFrameIdx 1.3.6.1.4.1.164.3.6.3.1.1.1.1
The prtGenPrtIdx index of this link. Slot*100+1.
OBJECT-TYPE    
  Integer32  

prtMlFrameSlt 1.3.6.1.4.1.164.3.6.3.1.1.1.2
This attribute indicates a unique number to identify the slot where the ML card is inserted.
OBJECT-TYPE    
  INTEGER kmxMlA(103), kmxMlB(104)  

prtMlBitWeight 1.3.6.1.4.1.164.3.6.3.1.1.1.3
This attribute indicates the Bit Weight [bps/bit] used for the selected prtMlFrameSlt. The Bit Weight is according to the ML Speed.
OBJECT-TYPE    
  INTEGER bps400(1), bps800(2), bps1600(3), bps3200(4), bps6400(5)  

prtMlDataUsage 1.3.6.1.4.1.164.3.6.3.1.1.1.4
Data usage in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value.
OBJECT-TYPE    
  Integer32  

prtMlControlSig 1.3.6.1.4.1.164.3.6.3.1.1.1.5
Control Signals usage of the ML in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value.
OBJECT-TYPE    
  Integer32  

prtMlDownload 1.3.6.1.4.1.164.3.6.3.1.1.1.6
Download bandwidth usage of the ML in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value.
OBJECT-TYPE    
  Integer32  

prtMlSync 1.3.6.1.4.1.164.3.6.3.1.1.1.7
Sync bandwidth usage of the ML in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value.
OBJECT-TYPE    
  Integer32  

prtMlTotalUsage 1.3.6.1.4.1.164.3.6.3.1.1.1.8
Total bandwidth usage of the ML in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value.
OBJECT-TYPE    
  Integer32  

prtMlTotalFree 1.3.6.1.4.1.164.3.6.3.1.1.1.9
Free bandwidth of the ML in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value.
OBJECT-TYPE    
  Integer32  

prtMlTable 1.3.6.1.4.1.164.3.6.3.1.2
Parameters for the main links. KML.1 - KML.6, KML.7(T1), KML.8(E1), KML.10(ISDN) and KML.F(KML.11 Fiber-optic).
OBJECT-TYPE    
  SEQUENCE OF  
    PrtMlEntry

prtMlEntry 1.3.6.1.4.1.164.3.6.3.1.2.1
An entry in table.
OBJECT-TYPE    
  PrtMlEntry  

prtMlCnfgIdx 1.3.6.1.4.1.164.3.6.3.1.2.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. Write operation for the table entries is allowed only to Config=255.
OBJECT-TYPE    
  Integer32 1..255  

prtMlIdx 1.3.6.1.4.1.164.3.6.3.1.2.1.2
The prtGenPrtIdx index of this link. Slot*100+1 .
OBJECT-TYPE    
  Integer32  

prtMlSlt 1.3.6.1.4.1.164.3.6.3.1.2.1.3
This attribute indicates a unique number to identify the slot where the ML card is inserted in.
OBJECT-TYPE    
  INTEGER kmxMlA(103), kmxMlB(104)  

prtMlTiming 1.3.6.1.4.1.164.3.6.3.1.2.1.4
The clock source for this link. For KML.1-KML.4, valid values: dte, eDce, or dce. For KML.5-KML.8, valid values: int or lbt. notApplicable - for KML.10 and KML.F.
OBJECT-TYPE    
  INTEGER notApplicable(1), dte(2), dce(3), eDce(4), int(5), lbt(6), adaptive(7)  

prtMlBufferSize 1.3.6.1.4.1.164.3.6.3.1.2.1.5
The buffer size in bits for absorbing timing jitters.
OBJECT-TYPE    
  INTEGER notApplicable(1), bits8(2), bits256(3)  

prtMlDsrCts 1.3.6.1.4.1.164.3.6.3.1.2.1.6
Determines the DSR and CTS signal handling. notApplicable - for KML.4-KML.6.
OBJECT-TYPE    
  INTEGER notApplicable(1), internal(2), external(3)  

prtMlSpeed 1.3.6.1.4.1.164.3.6.3.1.2.1.7
Determines the Main Link port speed. KML.1, KML.3, KML.4 support (Kbps): 9.6, 14.4, 19.2, 28.8, 32, 48, 56, 64, 128, 192, 256, 384, 512, 768, 1024, 1536. KML.2 supports (Kbps): 9.6, 14.4, 19.2, 28.8, 32, 48, 56, 64, 128 KML.5 supports (Kbps): 64, 128. KML.6 supports (Kbps): 9.6, 19.2, 56. KML.7-KML.8 support (Kbps): 56, 64, 128, 192, 256, 384, 512, 768, 1024, 1536. KML.10 supports (Kbps): 64, 128. KML.F supports (Kbps): 128, 256, 384, 512, 768, 1024, 1536.
OBJECT-TYPE    
  INTEGER bps9600(2), bps14400(3), bps19200(4), bps28800(5), bps32000(6), bps48000(7), bps56000(8), bps64000(9), bps128000(10), bps192000(11), bps256000(12), bps384000(13), bps512000(14), bps768000(15), bps1024000(16), bps1536000(17)  

prtMlStartTS 1.3.6.1.4.1.164.3.6.3.1.2.1.8
0=notApplicable - for all cards except KML.7, KML.8 For KML.7 - valid values: 1..24 For KML.8 - valid values: 1..31.
OBJECT-TYPE    
  Integer32 0..31  

prtMlBypassTs16 1.3.6.1.4.1.164.3.6.3.1.2.1.9
notApplicable - for all cards except KML.8.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtMlCallMode 1.3.6.1.4.1.164.3.6.3.1.2.1.10
This object will be used when using an external modem linked to the KML.1-KML.4 or KML.10 cards. Initiate - KML card can initiate calls to the modem Listen - KML card listens only ; cannot initiate a call.
OBJECT-TYPE    
  INTEGER notApplicable(1), initiate(2), listen(3)  

prtMlBondingEnable 1.3.6.1.4.1.164.3.6.3.1.2.1.11
Disable/Enable applying the Bonding process, for KML.10 cards. notApplicable - for all cards except KML.10.
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtMlIsdnTable 1.3.6.1.4.1.164.3.6.3.1.3
Parameters for ISDN main links: KML.10.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtMlIsdnEntry

prtMlIsdnEntry 1.3.6.1.4.1.164.3.6.3.1.3.1
An entry in table.
OBJECT-TYPE    
  PrtMlIsdnEntry  

prtMlIsdnCnfgIdx 1.3.6.1.4.1.164.3.6.3.1.3.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. Write operation for the table entries is allowed only to Config=255.
OBJECT-TYPE    
  Integer32 1..255  

prtMlIsdnIdx 1.3.6.1.4.1.164.3.6.3.1.3.1.2
The prtGenPrtIdx index of this link. Slot*100+1 .
OBJECT-TYPE    
  Integer32  

prtMlIsdnSlt 1.3.6.1.4.1.164.3.6.3.1.3.1.3
This attribute indicates a unique number to identify the slot where the ML card is inserted in.
OBJECT-TYPE    
  INTEGER kmxMlA(103), kmxMlB(104)  

prtMlIsdnMode 1.3.6.1.4.1.164.3.6.3.1.3.1.4
ISDN Mode. switched - when ML Mode is Switched Backup. leased - in all other cases.
OBJECT-TYPE    
  INTEGER leased(2), switched(3)  

prtMlIsdnStandard 1.3.6.1.4.1.164.3.6.3.1.3.1.5
The ISDN standard.
OBJECT-TYPE    
  INTEGER european(2), israeli(3), ess5Multipoint(4), ess5Ptp(5), dms100(6), ntt(7), nationalIsdn1(8)  

prtMlIsdnLocSubNum 1.3.6.1.4.1.164.3.6.3.1.3.1.6
Local sub-number. 4 chars (digits 0..9).
OBJECT-TYPE    
  DisplayString SIZE(0..25)  

prtMlIsdnLocNum 1.3.6.1.4.1.164.3.6.3.1.3.1.7
Local number. 20 chars (digits: 0..9).
OBJECT-TYPE    
  DisplayString SIZE(0..25)  

prtMlIsdnOutSubNum 1.3.6.1.4.1.164.3.6.3.1.3.1.8
Out sub-number. 4 chars (digits 0..9).
OBJECT-TYPE    
  DisplayString SIZE(0..25)  

prtMlIsdnBackupCallNum 1.3.6.1.4.1.164.3.6.3.1.3.1.9
Backup call number. 20 chars (digits: 0..9).
OBJECT-TYPE    
  DisplayString SIZE(0..25)  

prtMlIsdnInNumMode 1.3.6.1.4.1.164.3.6.3.1.3.1.10
In number mode.
OBJECT-TYPE    
  INTEGER none(2), all(3), local(4)  

prtHsLs 1.3.6.1.4.1.164.3.6.3.2
OBJECT IDENTIFIER    

prtHsLsTable 1.3.6.1.4.1.164.3.6.3.2.1
Parameters for the High and Low speed channels. Cards: KLS.1,KLS.2, KHS.1, KHS.2, KDI/CH, KHSU.1, KHSU.2, KHS.703.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHsLsEntry

prtHsLsEntry 1.3.6.1.4.1.164.3.6.3.2.1.1
An entry in table.
OBJECT-TYPE    
  PrtHsLsEntry  

prtHsLsCnfgIdx 1.3.6.1.4.1.164.3.6.3.2.1.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. Write operation for the table entries is allowed only to Config=255.
OBJECT-TYPE    
  Integer32 1..255  

prtHsLsIdx 1.3.6.1.4.1.164.3.6.3.2.1.1.2
The prtGenPrtIdx index of this channel. In KHSU.1 and KHSU.2 there are three ISDN sub-channels on each port (2B+D).The sub-channels are numbered: Slot*100+11 ; Slot*100+12 ; Slot*100+13 (First Port), Slot*100+14 ; Slot*100+15 ; Slot*100+16 (Second Port).
OBJECT-TYPE    
  Integer32  

prtHsLsSlt 1.3.6.1.4.1.164.3.6.3.2.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid. The entry kmxOpt(106) is valid only for KDI/CH card.
OBJECT-TYPE    
  INTEGER kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

prtHsLsCommProtocol 1.3.6.1.4.1.164.3.6.3.2.1.1.4
The communication protocol.
OBJECT-TYPE    
  INTEGER notApplicable(1), async(2), sync(3)  

prtHsLsAsyncDataLen 1.3.6.1.4.1.164.3.6.3.2.1.1.5
Async Data Length in Bits. notApplicable - when prtHsLsCommProtocol=sync or notApplicable.
OBJECT-TYPE    
  INTEGER notApplicable(1), bit6(2), bit7(3), bit8(4), bit9(5)  

prtHsLsTiming 1.3.6.1.4.1.164.3.6.3.2.1.1.6
The variable is RW only if the communications protocol is sync. When the comm protocol is async, the variable is RO and its value is DCE.
OBJECT-TYPE    
  INTEGER notApplicable(1), dce(2), dte1(3), dte2(4)  

prtHsLsCtrlSignal 1.3.6.1.4.1.164.3.6.3.2.1.1.7
Control signals.
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), dtrAndRts(3), rts(4)  

prtHsLsCts 1.3.6.1.4.1.164.3.6.3.2.1.1.8
CTS Signal.
OBJECT-TYPE    
  INTEGER notApplicable(1), equalRts(2), on(3)  

prtHsLsRtsCtsDelay 1.3.6.1.4.1.164.3.6.3.2.1.1.9
RTS-CTS delay in ms. notApplicable - when prtHsLsCts=on.
OBJECT-TYPE    
  INTEGER notApplicable(1), min(2), ms10(3), ms50(4), ms100(5), ms200(6)  

prtHsLsDsrMode 1.3.6.1.4.1.164.3.6.3.2.1.1.10
DSR Mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), permanentOn(2), sync(3)  

prtHsLsSpeed 1.3.6.1.4.1.164.3.6.3.2.1.1.11
KLS.1 supports (Kbps): 0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4. KLS.1/New, KDI/CH support (Kbps): Group 1: 0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4 Group 2: 7.2, 14.4, 28.8, 57.6 Group 3: 8, 16, 24, 32, 48, 56, 64 KLS.2 supports (Kbps): 2.4, 4.8, 9.6, 19.2. KHS.1 supports (Kbps): 32, 48, 56, 64, 128, 192, 256, 384 KHS.2 supports (Kbps): ... KHSU.1/2 support (Kbps): 16, 32, 64. KHS.703 support (Kbps): 64.
OBJECT-TYPE    
  INTEGER notConnected(1), bps300(2), bps600(3), bps1200(4), bps2400(5), bps4800(6), bps7200(7), bps8000(8), bps9600(9), bps12000(10), bps14400(11), bps16000(12), bps16800(13), bps19200(14), bps21600(15), bps24000(16), bps26400(17), bps28800(18), bps31200(19), bps32000(20), bps33600(21), bps36000(22), bps38400(23), bps40800(24), bps43200(25), bps45600(26), bps48000(27), bps50400(28), bps52800(29), bps55200(30), bps56000(31), bps57600(32), bps60000(33), bps62400(34), bps64000(35), bps64800(36), bps67200(37), bps69600(38), bps72000(39), bps74400(40), bps76800(41), bps79200(42), bps81600(43), bps84000(44), bps86400(45), bps88800(46), bps91200(47), bps93600(48), bps96000(49), bps98400(50), bps100800(51), bps103200(52), bps105600(53), bps108000(54), bps110400(55), bps112800(56), bps115200(57), bps117600(58), bps120000(59), bps122400(60), bps124800(61), bps127200(62), bps128000(63), bps129600(64), bps134400(65), bps139200(66), bps144000(67), bps148800(68), bps153600(69), bps158400(70), bps163200(71), bps168000(72), bps172800(73), bps177600(74), bps182400(75), bps187200(76), bps192000(77), bps196800(78), bps201600(79), bps206400(80), bps211200(81), bps216000(82), bps220800(83), bps225600(84), bps230400(85), bps235200(86), bps240000(87), bps244800(88), bps249600(89), bps254400(90), bps256000(91), bps259200(92), bps264000(93), bps268800(94), bps273600(95), bps278400(96), bps283200(97), bps288000(98), bps292800(99), bps297600(100), bps302400(101), bps307200(102), bps316800(103), bps326400(104), bps336000(105), bps345600(106), bps355200(107), bps364800(108), bps374400(109), bps384000(110), bps393600(111), bps403200(112), bps412800(113), bps422400(114), bps432000(115), bps441600(116), bps451200(117), bps460800(118), bps470400(119), bps480000(120), bps489600(121), bps499200(122), bps508800(123), bps518400(124), bps528000(125), bps537600(126), bps547200(127), bps556800(128), bps566400(129), bps576000(130), bps585600(131), bps595200(132), bps604800(133), bps614400(134)  

prtHsLsUType 1.3.6.1.4.1.164.3.6.3.2.1.1.12
U Interface Type. Applicable for KHSU.1/2 cards. The value will be the same for B1 and B2 pair; B3 and B4.
OBJECT-TYPE    
  INTEGER notApplicable(1), regular(2), type1(3)  

prtTreMbe 1.3.6.1.4.1.164.3.6.3.3
OBJECT IDENTIFIER    

prtTreMbeTable 1.3.6.1.4.1.164.3.6.3.3.2
The write operation into the Table Objects is valid only to the TmpCnfg entry. Parameters for the channels of the TRE and MBE cards: KTRE, KMBE, KMBE/NEW.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtTreMbeEntry

prtTreMbeEntry 1.3.6.1.4.1.164.3.6.3.3.2.1
An entry in table.
OBJECT-TYPE    
  PrtTreMbeEntry  

prtTreMbeCnfgIdx 1.3.6.1.4.1.164.3.6.3.3.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtTreMbeIdx 1.3.6.1.4.1.164.3.6.3.3.2.1.2
A unique port identifier within the card. Slot*100+11 .
OBJECT-TYPE    
  Integer32  

prtTreMbeSlt 1.3.6.1.4.1.164.3.6.3.3.2.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid.
OBJECT-TYPE    
  INTEGER kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

prtTreMbeLan 1.3.6.1.4.1.164.3.6.3.3.2.1.4
This attribute indicates whether the TRE/MBE port is operated as main or remote bridge. Default=remote.
OBJECT-TYPE    
  INTEGER notApplicable(1), main(2), remote(3)  

prtTreMbeLanRate 1.3.6.1.4.1.164.3.6.3.3.2.1.5
This attribute indicates the Rate of the TRE port in Mbit/sec. Default-r4M.
OBJECT-TYPE    
  INTEGER notApplicable(1), r4M(2), r16M(3)  

prtTreMbeLinkSpeed 1.3.6.1.4.1.164.3.6.3.3.2.1.6
The Link Speed.
OBJECT-TYPE    
  INTEGER notConnected(1), bps9600(2), bps19200(3), bps28800(4), bps38400(5), bps48000(6), bps57600(7), bps67200(8), bps76800(9), bps86400(10), bps96000(11), bps105600(12), bps115200(13), bps124800(14), bps128000(15), bps160000(16), bps192000(17), bps224000(18), bps240000(19), bps272000(20), bps304000(21), bps336000(22), bps368000(23)  

prtVoiceFax 1.3.6.1.4.1.164.3.6.3.4
OBJECT IDENTIFIER    

prtVoiceFaxTable 1.3.6.1.4.1.164.3.6.3.4.1
The write operation into the Table Objects is valid only to the TmpCnfg entry. Parameters for the channels of the Voice and Fax channels. Cards: KVC.1/E&M, KVC.1/FXO, KVC.1/FXS, KVC.1M/E&M, KVC.1M/FXO, KVC.1M/FXS, KVC.1M/FXSW, KVC.2/E&M, KVC.2/FXO, KVC.2/FXS, KVC.2/1/E&M,KVC.2/1/FXO,KVC.2/1/FXS, KVC.3/E&M, KVC.3/FXO, KVC.3/FXS, KVC.3/S0 KVF.1/E&M, KVF.1/FXO, KVF.1/FXS, KVF.3/E&M, KVF.3/FXO, KVF.3/FXS, KVF.4/E&M, KVF.4/FXO, KVF.4/FXS, KVF.4/FXSW, KVF.4/S0, KVF.4/FXO3, KVF.4/FXS3, KVF.4/NS0 KVF.5 family, KVF.6 family, KVF.8 family.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtVoiceFaxEntry

prtVoiceFaxEntry 1.3.6.1.4.1.164.3.6.3.4.1.1
An entry in table.
OBJECT-TYPE    
  PrtVoiceFaxEntry  

prtVoiceFaxCnfgIdx 1.3.6.1.4.1.164.3.6.3.4.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

prtVoiceFaxIdx 1.3.6.1.4.1.164.3.6.3.4.1.1.2
A unique identifier of the port, within the card. Slot*100+Ch external ports: Ch=1..10 internal ports (sub-channels): Ch=11..20.
OBJECT-TYPE    
  Integer32  

prtVoiceFaxSlt 1.3.6.1.4.1.164.3.6.3.4.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid.
OBJECT-TYPE    
  INTEGER kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

prtVoiceFaxTransGain 1.3.6.1.4.1.164.3.6.3.4.1.1.4
Transmit gain in dBm. A value of 255 is for notApplicable. The value will be: real value+50dBm (in order to avoid negative values).
OBJECT-TYPE    
  Integer32  

prtVoiceFaxReceiveGain 1.3.6.1.4.1.164.3.6.3.4.1.1.5
Receive gain in dBm. A value of 255 is for notApplicable. The value will be: real value+50dBm (in order to avoid negative values).
OBJECT-TYPE    
  Integer32  

prtVoiceFaxWire 1.3.6.1.4.1.164.3.6.3.4.1.1.6
Applicable only for E&M cards.
OBJECT-TYPE    
  INTEGER notApplicable(1), w2wire(2), w4wire(3)  

prtVoiceFaxTimeOut 1.3.6.1.4.1.164.3.6.3.4.1.1.7
Fax timeout in seconds.
OBJECT-TYPE    
  INTEGER notApplicable(1), manual(2), sec30(3), sec60(4), sec90(5)  

prtVoiceFaxEchoCanceler 1.3.6.1.4.1.164.3.6.3.4.1.1.8
Echo canceler activation.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtVoiceFaxSpeed 1.3.6.1.4.1.164.3.6.3.4.1.1.9
The channel speed. For KVF.6 and KVF.8 cards, each value will represent [4 x value], since each channel (Internal or External) is comprised of 4 sub-channels having the selected value.
OBJECT-TYPE    
  INTEGER notConnected(1), bps4800(2), bps6400(3), bps7200(4), bps8000(5), bps9600(6), bps12800(7), bps16000(8), bps24000(9), bps32000(10), bps64000(11), bps11200(12)  

prtVoiceFaxMeterRate 1.3.6.1.4.1.164.3.6.3.4.1.1.10
This entry is valid to KVF.4/FXO3 and KVF.4/FXS3. Meter Rate means rate of Call Meter in Public Phones, in KHz units. Must be equal for both channels.
OBJECT-TYPE    
  INTEGER notApplicable(1), r16Khz(2), r12Khz(3)  

prtVoiceFaxCodingLaw 1.3.6.1.4.1.164.3.6.3.4.1.1.11
Coding Law. This entry is valid for KVF.4/NS0 external channel and KVF.6 internal channels.
OBJECT-TYPE    
  INTEGER notApplicable(1), aLaw(2), uLaw(3)  

prtVoiceFaxOperMode 1.3.6.1.4.1.164.3.6.3.4.1.1.12
Operation Mode. This parameter is valid for KVF.6 and KVF.8 family.
OBJECT-TYPE    
  INTEGER notApplicable(1), voiceANDfax(2), voice(3), voiceAndFaxAndData(4)  

prtVoiceFaxSigInOutband 1.3.6.1.4.1.164.3.6.3.4.1.1.13
This object is applicable for KVF.4/FXO3, KVF.4/FXS3, KVF.8 family cards. For KVF.4/FXO3, KVF.4/FXS3: Octet 1 for Receive parameters. Octet 2 for Transmit parameters. It represents 4 parameters, in each Octet : Bit 7 6 5 4 3 2 1 0 |_____| |_____| |_____| |_____| MSB Spare On/Off Hook Metering Polarity LSB Each parameter's bits represent: 00 = NC 01 = Inband(A/B) 10 = Outband(A) 11 = Outband(B) For KVF.8 family: It represents 4 parameters, by 2 Octets : General Bit Code- MSB nibble, On/Off Hook Bit Code- nibble, Metering Bit Code- nibble, Polarity Bit Code- LSB nibble. Each of General, On/Off Hook, Metering, Polarity Bit Code nibble represents: 0 hex = 0000 = 0 1 hex = 0001 = 1 2 hex = 0010 = A bit 3 hex = 0011 = B bit 4 hex = 0100 = C bit 5 hex = 0101 = D bit 6 hex = 0110 = A bit inverse 7 hex = 0111 = B bit inverse 8 hex = 1000 = C bit inverse 9 hex = 1001 = D bit inverse A-E hex - not used (invalid values) When the object is not applicable, 0 Octets will be sent.
OBJECT-TYPE    
  OCTET STRING SIZE(2)  

prtVoiceFaxTsGroup 1.3.6.1.4.1.164.3.6.3.4.1.1.14
Ts Assignment group. Each KVF.6 internal channel should have a different value. 's21s22s23s24' = TSs: 21, 22, 23, 24 For KVF.6/E1/16, KVF.6/E1/31 values: 2..9 are applicable. For KVF.6/T1/12, KVF.6/T1/24 values: 2..7 are applicable.
OBJECT-TYPE    
  INTEGER notApplicable(1), s1s2s3s4(2), s5s6s7s8(3), s9s10s11s12(4), s13s14s15s16(5), s17s18s19s20(6), s21s22s23s24(7), s25s26s27s28(8), s29s30s31(9)  

prtVoiceFaxRxFaxGain 1.3.6.1.4.1.164.3.6.3.4.1.1.15
FAX Receive gain in dBm. The value will be: (real value*10)+500dBm (in order to avoid negative and fractional values).
OBJECT-TYPE    
  Integer32  

prtVoiceFaxSigHold 1.3.6.1.4.1.164.3.6.3.4.1.1.16
Signal Hold in [sec]. Applicable for all KVF.4 cards except S0/NS0. When a ML fails, instead of interrupting immediately a conversation and connecting it again when ML operation is resumed, user can select to Hold the signal a few seconds before interruption (ML operation may return during this time). sec0 = No Hold = 0 sec sec10= 10 sec hold.
OBJECT-TYPE    
  INTEGER notApplicable(1), sec0(2), sec10(3)  

prtVoiceFaxIfSignaling 1.3.6.1.4.1.164.3.6.3.4.1.1.17
Applicable only for KVF.8/FXO, KVF.8/FXS cards. Interface Analog Signaling.
OBJECT-TYPE    
  INTEGER notApplicable(1), loopStart(2), groundStart(3), winkStart(4)  

prtVoiceFaxEMTypes 1.3.6.1.4.1.164.3.6.3.4.1.1.18
Applicable only for KVF.8/E&M card.
OBJECT-TYPE    
  INTEGER notApplicable(1), em1(2), em2(3), em3(4), ssdc5(5)  

prtVoiceFaxRingFrequency 1.3.6.1.4.1.164.3.6.3.4.1.1.19
Applicable only for KVF.8/E&M card. The Ringing Frequency units will be in Hz.
OBJECT-TYPE    
  INTEGER notApplicable(1), f16dot7Hz(2), f20Hz(3), f25Hz(4), f50Hz(5)  

prtVoiceFaxSignalingStatus 1.3.6.1.4.1.164.3.6.3.4.1.1.20
For KM-2100 this parameter should be Read Only. This object is applicable for KVF.6 and KVF.5 family cards. It shows the status (0 or 1) of each Signaling Bit (A, B, C, D), for each TS of a TS Group (according to it's position in the group). Each nibble represent a TS from the 'TS Group' selected for the channel (two Octets represents 4 TSs of each group): Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 |________| |________| |________| |________| MSB TS i+3 TS i+2 TS i+1 TS i LSB It represents 4 parameters for each TS: TS-i TS-i+1 .. 0 - A bit 4 - A bit 1 - B bit 5 - B bit 2 - C bit 6 - C bit 3 - D bit 7 - D bit When the object is not applicable, 0 Octets will be sent.
OBJECT-TYPE    
  OCTET STRING SIZE(0..2)  

imx 1.3.6.1.4.1.164.3.7
OBJECT IDENTIFIER    

systemImx 1.3.6.1.4.1.164.3.7.1
OBJECT IDENTIFIER    

generalImx 1.3.6.1.4.1.164.3.7.1.1
OBJECT IDENTIFIER    

sysGenClearAlarm 1.3.6.1.4.1.164.3.7.1.1.1
Clear the alarm buffer. The agent resets the variable automatically to off.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

sysGenAlarmBuffTable 1.3.6.1.4.1.164.3.7.1.1.2
The alarm buffer of the imx.
OBJECT-TYPE    
  SEQUENCE OF  
    SysGenAlarmBuffEntry

sysGenAlarmBuffEntry 1.3.6.1.4.1.164.3.7.1.1.2.1
An entry in table sysGenAlarmBuffTable.
OBJECT-TYPE    
  SysGenAlarmBuffEntry  

sysGenAlarmBuffIndex 1.3.6.1.4.1.164.3.7.1.1.2.1.1
The index of the alarm buffer Table.
OBJECT-TYPE    
  Integer32 1..100  

sysGenAlarmDescr 1.3.6.1.4.1.164.3.7.1.1.2.1.2
The description of the alarm. Up to 80 chars.
OBJECT-TYPE    
  DisplayString  

sysGenClearLog 1.3.6.1.4.1.164.3.7.1.1.3
Clear the log buffer. The agent resets the variable automatically to off.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

sysGenLogTable 1.3.6.1.4.1.164.3.7.1.1.4
The call log buffer of the imx.
OBJECT-TYPE    
  SEQUENCE OF  
    SysGenLogEntry

sysGenLogEntry 1.3.6.1.4.1.164.3.7.1.1.4.1
An entry in table sysGenLogTable.
OBJECT-TYPE    
  SysGenLogEntry  

sysGenLogIndex 1.3.6.1.4.1.164.3.7.1.1.4.1.1
The index of the log Table.
OBJECT-TYPE    
  Integer32 1..100  

sysGenLogDescr 1.3.6.1.4.1.164.3.7.1.1.4.1.2
The description of the entry in the log buffer. Up to 80 chars.
OBJECT-TYPE    
  DisplayString  

profilesImx 1.3.6.1.4.1.164.3.7.1.2
OBJECT IDENTIFIER    

callProfileImx 1.3.6.1.4.1.164.3.7.1.2.1
OBJECT IDENTIFIER    

sysCallProfileTable 1.3.6.1.4.1.164.3.7.1.2.1.1
A table containing call profile parameters. There are 40 call profiles.
OBJECT-TYPE    
  SEQUENCE OF  
    SysCallProfileEntry

sysCallProfileEntry 1.3.6.1.4.1.164.3.7.1.2.1.1.1
An entry in table sysCallProfileTable.
OBJECT-TYPE    
  SysCallProfileEntry  

sysCallProfileIndex 1.3.6.1.4.1.164.3.7.1.2.1.1.1.1
A running index for the table.
OBJECT-TYPE    
  Integer32 1..40  

sysCallProfileConnectCmd 1.3.6.1.4.1.164.3.7.1.2.1.1.1.2
On(2) - Connect the call profile. The agent will automatically reset the variable to off(1) .
OBJECT-TYPE    
  INTEGER off(1), on(2)  

sysCallProfileDisconnectCmd 1.3.6.1.4.1.164.3.7.1.2.1.1.1.3
On(2) - Disconnect the call profile. The agent will automatically reset the variable to off(1).
OBJECT-TYPE    
  INTEGER off(1), on(2)  

sysCallProfileIncrBwCmd 1.3.6.1.4.1.164.3.7.1.2.1.1.1.4
Increment bandwidth of a call. The number of channels to increment 1..6. The agent will automatically reset the variable to 0.
OBJECT-TYPE    
  Integer32 0..6  

sysCallProfileDecrBwCmd 1.3.6.1.4.1.164.3.7.1.2.1.1.1.5
Decrement bandwidth of a call. The number of channels to decrement 1..6. The agent will automatically reset the variable to 0.
OBJECT-TYPE    
  Integer32 0..6  

portImx 1.3.6.1.4.1.164.3.7.2
OBJECT IDENTIFIER    

userPortImx 1.3.6.1.4.1.164.3.7.2.1
OBJECT IDENTIFIER    

prtCnfgTable 1.3.6.1.4.1.164.3.7.2.1.1
A table containing configuration parameters for the user ports.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCnfgEntry

prtCnfgEntry 1.3.6.1.4.1.164.3.7.2.1.1.1
An entry in table prtCnfgTable.
OBJECT-TYPE    
  PrtCnfgEntry  

prtIndex 1.3.6.1.4.1.164.3.7.2.1.1.1.1
The user port index.
OBJECT-TYPE    
  Integer32 1..2  

prtCnfgDecrBwChNum 1.3.6.1.4.1.164.3.7.2.1.1.1.2
Decrement the port bandwidth by the specified number of channels. The agent resets the variable to 0.
OBJECT-TYPE    
  Integer32 0..6  

prtCnfgIncrBwChNum 1.3.6.1.4.1.164.3.7.2.1.1.1.3
Increment the port bandwidth by the specified number of channels. The agent resets the variable to 0.
OBJECT-TYPE    
  Integer32 0..6  

prtCnfgDisconnect 1.3.6.1.4.1.164.3.7.2.1.1.1.4
Disconnect the port (on(1)). The agent resets the variable to off(2).
OBJECT-TYPE    
  INTEGER on(1), off(2)  

prtCnfgActivateLoop 1.3.6.1.4.1.164.3.7.2.1.1.1.5
Activate the desired loop on the port. The agent will reset the variable to none(1).
OBJECT-TYPE    
  INTEGER none(1), local(2), remote(3), bonding(4)  

prtCnfgClearLoop 1.3.6.1.4.1.164.3.7.2.1.1.1.6
Clear the desired loop from the port. The agent will reset the variable to none(1)
OBJECT-TYPE    
  INTEGER none(1), local(2), remote(3), bonding(4), all(5)  

prtCnfgLoopStatus 1.3.6.1.4.1.164.3.7.2.1.1.1.7
The loop status at this port. The variable is a sum of 2**n where n is as follows: 0 - Local Loop is on. 1 - Remote Loop is on. 2 - BONDING Loop is on. If the variable is 0, there is no active loop.
OBJECT-TYPE    
  Integer32  

supervisoryPortImx 1.3.6.1.4.1.164.3.7.2.2
OBJECT IDENTIFIER    

prtSpUsageImx 1.3.6.1.4.1.164.3.7.2.2.1
The supervisory port terminal usage definition.
OBJECT-TYPE    
  INTEGER nmsSlip(2), terminal(3)  

channelImx 1.3.6.1.4.1.164.3.7.4
OBJECT IDENTIFIER    

channelCnfgTable 1.3.6.1.4.1.164.3.7.4.1
A table containing configuration parameters for the channels.
OBJECT-TYPE    
  SEQUENCE OF  
    ChannelCnfgEntry

channelCnfgEntry 1.3.6.1.4.1.164.3.7.4.1.1
An entry in table channelCnfgTable.
OBJECT-TYPE    
  ChannelCnfgEntry  

chIndex 1.3.6.1.4.1.164.3.7.4.1.1.1
The channel index.
OBJECT-TYPE    
  Integer32 1..6  

chCnfgUnlock 1.3.6.1.4.1.164.3.7.4.1.1.2
Unlock the channel (on). The agent resets the variable to off.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

chCnfgPing 1.3.6.1.4.1.164.3.7.4.1.1.3
Ping the channel (on). The agent resets the variable to off.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

channelStatTable 1.3.6.1.4.1.164.3.7.4.2
A table containing status and statistics information for the channels.
OBJECT-TYPE    
  SEQUENCE OF  
    ChannelStatEntry

channelStatEntry 1.3.6.1.4.1.164.3.7.4.2.1
An entry in table channelStatTable.
OBJECT-TYPE    
  ChannelStatEntry  

chStatOperStatus 1.3.6.1.4.1.164.3.7.4.2.1.1
The operational state of the channel based on a ping operation.
OBJECT-TYPE    
  INTEGER up(1), down(2), engaged(3), notDedicated(4)  

radBridges 1.3.6.1.4.1.164.4
OBJECT IDENTIFIER    

genBridge 1.3.6.1.4.1.164.4.1
OBJECT IDENTIFIER    

radBridgeAction 1.3.6.1.4.1.164.4.1.1
This variable enables the operator to perform one of the specified actions on the tables maintained by the network device. Send actions are not currently implemented. Not all actions can be performed on all bridges.
OBJECT-TYPE    
  INTEGER reset(1), sendNetworkTab(2), deleteNetworkTab(3), sendRoutingTab(4), deleteRoutinTab(5), sendLanTab(6), deleteLanTab(7), deleteArpTab(8), sendArpTab(9), deleteRouteTab(10), sendRouteTab(11), deactivateAllMasks(12), saveAllActiveMasks(13), loadAndActivateAllMasksFromNVRAM(14), clearAllMasksFromNVRAM(15), defaultConfig(16), resetNVRAM(17), clearIPNVRAM(18), noOp(255)  

radBridgeInactiveArpTimeOut 1.3.6.1.4.1.164.4.1.2
This variable defines the maximum time period that can pass between ARP requests concerning an entry in the ARP table. After this time period, the entry is deleted from the table.
OBJECT-TYPE    
  Integer32  

radBridgeMaskTable 1.3.6.1.4.1.164.4.1.3
Mask tables enable definition of forwarding restrictions and control of message flow in the internetwork. Each entry in this table defines a mask statement consisting of up to three mask definitions and an action defined by radBridgeMaskOper. Different types of mask entries are supported, as defined by radBridgeMaskType.
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeMaskEntry

radBridgeMaskEntry 1.3.6.1.4.1.164.4.1.3.1
An entry in table radBridgeMaskTable.
OBJECT-TYPE    
  RadBridgeMaskEntry  

radBridgeMaskType 1.3.6.1.4.1.164.4.1.3.1.1
Defines the type of mask entry.
OBJECT-TYPE    
  INTEGER tx(1), rx(2), compress(3), priority(4), loadSharing(5), facs(6), codConnect(7), codDisconnect(8)  

radBridgeMaskIfIndex 1.3.6.1.4.1.164.4.1.3.1.2
Specifies the if Index of the interface to which the mask is applied.
OBJECT-TYPE    
  Integer32  

radBridgeMaskNum 1.3.6.1.4.1.164.4.1.3.1.3
The Mask entry number, defined by its line number in the mask table.
OBJECT-TYPE    
  Integer32  

radBridgeMaskDest 1.3.6.1.4.1.164.4.1.3.1.4
Specifies the type of destination address carried by the frame to which the mask will be applied. Unassigned-condition deactivates the mask entry.
OBJECT-TYPE    
  INTEGER unassigned-cond(1), broadcast-msge(2), multicast-msge(3), all-msge(4), none(5)  

radBridgeMaskPat1 1.3.6.1.4.1.164.4.1.3.1.5
Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern.
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskActiveBit1 1.3.6.1.4.1.164.4.1.3.1.6
Specifies the positions of the wild card characters (*) in the radBridgeMaskPat1 field.
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskFrom1 1.3.6.1.4.1.164.4.1.3.1.7
Offset base of radBridgeMaskPat1 within the frame. Net can be in some cases the data start point.
OBJECT-TYPE    
  INTEGER mac(1), llc(2), net(3)  

radBridgeMaskOffset1 1.3.6.1.4.1.164.4.1.3.1.8
Specifies the radBridgeMaskPat1 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm1.The mask offset is an even decimal number in the range of 0 to 1518.
OBJECT-TYPE    
  Integer32  

radBridgeMaskCond1 1.3.6.1.4.1.164.4.1.3.1.9
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset1 the packet contains data that matches the content of radBridgeMaskPat1. false - Condition is valid if at the position specified by radBridgeMaskOffset1 the packet contains data that does not match the content of radBridgeMaskPat1.
OBJECT-TYPE    
  INTEGER false(1), true(2)  

radBridgeMaskPat2 1.3.6.1.4.1.164.4.1.3.1.10
Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern.
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskActiveBit2 1.3.6.1.4.1.164.4.1.3.1.11
Specifies the positions of the wild card characters (*) in the radBridgeMaskPat2 field.
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskFrom2 1.3.6.1.4.1.164.4.1.3.1.12
Offset base of radBridgeMaskPat2 within the frame. Net can be in some cases the data start point.
OBJECT-TYPE    
  INTEGER mac(1), llc(2), net(3)  

radBridgeMaskOffset2 1.3.6.1.4.1.164.4.1.3.1.13
Specifies the radBridgeMaskPat2 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm2.The mask offset is an even decimal number in the range of 0 to 1518.
OBJECT-TYPE    
  Integer32  

radBridgeMaskCond2 1.3.6.1.4.1.164.4.1.3.1.14
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset2 the packet contains data that matches the content of radBridgeMaskPat2. false - Condition is valid if at the position specified by radBridgeMaskOffset2 the packet contains data that does not match the content of radBridgeMaskPat2.
OBJECT-TYPE    
  INTEGER false(1), true(2)  

radBridgeMaskPat3 1.3.6.1.4.1.164.4.1.3.1.15
Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern.
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskActiveBit3 1.3.6.1.4.1.164.4.1.3.1.16
Specifies the positions of the wild card characters (*) in the radBridgeMaskPat3 field.
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskFrom3 1.3.6.1.4.1.164.4.1.3.1.17
Offset base of radBridgeMaskPat3 within the frame. Net can be in some cases the data start point.
OBJECT-TYPE    
  INTEGER mac(1), llc(2), net(3)  

radBridgeMaskOffset3 1.3.6.1.4.1.164.4.1.3.1.18
Specifies the radBridgeMaskPat3 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm3. The mask offset is an even decimal number in the range of 0 to 1518.
OBJECT-TYPE    
  Integer32  

radBridgeMaskCond3 1.3.6.1.4.1.164.4.1.3.1.19
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset3 the packet contains data that matches the content of radBridgeMaskPat3 false - Condition is valid if at the position specified by radBridgeMaskOffset3 the packet contains data that does not match the content of radBridgeMaskPat3.
OBJECT-TYPE    
  INTEGER false(1), true(2)  

radBridgeMaskOper 1.3.6.1.4.1.164.4.1.3.1.20
The type of action to be taken if the frame meets the conditions of the mask. noOp = disabled (mask remains on list, but is not active) delete = mask is removed from the list.
OBJECT-TYPE    
  INTEGER block(1), forward(2), route(3), forward-route(4), high-priority(5), noOp(6), delete(7)  

radBridgeCOD 1.3.6.1.4.1.164.4.1.4
OBJECT IDENTIFIER    

radBridgeCODParamTable 1.3.6.1.4.1.164.4.1.4.1
The table of COD parameters
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeCODEntry

radBridgeCODEntry 1.3.6.1.4.1.164.4.1.4.1.1
Each radBridgeCODEntry consists of the following parameters
OBJECT-TYPE    
  RadBridgeCODEntry  

radBridgeCODIfIndex 1.3.6.1.4.1.164.4.1.4.1.1.1
The interface to which this COD entry is applicable.
OBJECT-TYPE    
  Integer32  

radBridgeCODManualConnect 1.3.6.1.4.1.164.4.1.4.1.1.2
The management station can start connection manually by setting this parameter
OBJECT-TYPE    
  INTEGER connect(1), disconnect(2)  

radBridgeCODMode 1.3.6.1.4.1.164.4.1.4.1.1.3
In answer mode only one incoming call may be accepted at a time. Other nodes attempting to access the local modem will receive a busy signal until the connection is terminated. (Answer mode has no difficulty supporting multiple remote connections to one local port, as blocking multiple incoming calls is just a modem function. Originate mode, on the other hand will only support a single local port to remote port connection). The disable parameter disables the COD utility for this interface. Choosing any other mode will enable the COD utility.
OBJECT-TYPE    
  INTEGER answer(1), originate(2), disable(3), answerAndOriginate(4)  

radBridgeCODConnectDelay 1.3.6.1.4.1.164.4.1.4.1.1.4
The connect delay defines the minimum time period that the link must stay disconnected, between 2 succesive connections (in seconds).
OBJECT-TYPE    
  Integer32  

radBridgeCODisConnectDelay 1.3.6.1.4.1.164.4.1.4.1.1.5
The disconnect delay defines the minimum time period the link must stay connected, between 2 succesive disconnections (in seconds).
OBJECT-TYPE    
  Integer32  

radBridgeCODImplicitSwitch 1.3.6.1.4.1.164.4.1.4.1.1.6
The inplicit switch allows the user to ignore implicit triggers provided by the COD software.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

radBridgeCODNumAccess 1.3.6.1.4.1.164.4.1.4.1.1.7
The number of successful connections that have been established since the COD has been reset.
OBJECT-TYPE    
  Counter32  

radBridgeCODTotalConnecTime 1.3.6.1.4.1.164.4.1.4.1.1.8
The sum of all the connect time intervals since the COD was reset.
OBJECT-TYPE    
  Integer32  

radBridgeCODTimeTriggerTable 1.3.6.1.4.1.164.4.1.4.2
The table of COD parameters
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeCODTimeTriggerEntry

radBridgeCODTimeTriggerEntry 1.3.6.1.4.1.164.4.1.4.2.1
Each radBridgeCODTimeTriggerEntry consists of the following parameters
OBJECT-TYPE    
  RadBridgeCODTimeTriggerEntry  

radBridgeCODTimeIfIndex 1.3.6.1.4.1.164.4.1.4.2.1.1
The interface to which this COD Time Trigger entry is applicable.
OBJECT-TYPE    
  Integer32  

radBridgeCODDay 1.3.6.1.4.1.164.4.1.4.2.1.2
The day of the week in which the dial up connection operates.
OBJECT-TYPE    
  INTEGER mon(1), tue(2), wed(3), thu(4), fri(5), sat(6), sun(7)  

radBridgeCODTimeTriggerNum 1.3.6.1.4.1.164.4.1.4.2.1.3
Every day of the week the user can configure 3 dial up connections.
OBJECT-TYPE    
  Integer32 1..3  

radBridgeCODTimeTriggerFrom 1.3.6.1.4.1.164.4.1.4.2.1.4
Time to start Dial Up connection, in format hh:mm.
OBJECT-TYPE    
  DisplayString  

radBridgeCODTimeTriggerTo 1.3.6.1.4.1.164.4.1.4.2.1.5
Time to terminate Dial Up connection, in format HH:MM.
OBJECT-TYPE    
  DisplayString  

radBridgeCODTimeTriggerStatus 1.3.6.1.4.1.164.4.1.4.2.1.6
The status of a table entry.
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

radBridgeCODTraffic 1.3.6.1.4.1.164.4.1.4.3
OBJECT IDENTIFIER    

radBridgeCODTrafficTable 1.3.6.1.4.1.164.4.1.4.3.1
The table of COD Traffic trigger
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeCODTrafficEntry

radBridgeCODTrafficEntry 1.3.6.1.4.1.164.4.1.4.3.1.1
Each radBridgeCODTrafficEntry consists of the following parameters.
OBJECT-TYPE    
  RadBridgeCODTrafficEntry  

radBridgeCODProtocolType 1.3.6.1.4.1.164.4.1.4.3.1.1.1
The Protocol Type of the Traffic Table
OBJECT-TYPE    
  INTEGER ip(1), ipx(2), other(3)  

radBridgeCODTrafficTriggerStatus 1.3.6.1.4.1.164.4.1.4.3.1.1.2
Command of Status of the Protocol Traffic Trigger
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

radBridgeCODRemoteIPAddr 1.3.6.1.4.1.164.4.1.4.3.2
This is the Remote IP Address
OBJECT-TYPE    
  IpAddress  

radBridgeCODIPMask 1.3.6.1.4.1.164.4.1.4.3.3
This is the Mask of the Remote IP Address
OBJECT-TYPE    
  IpAddress  

radBridgeCODTrafficTriggerProtType 1.3.6.1.4.1.164.4.1.4.3.4
Protocol Type for the User Defined Protocol Traffic Trigger (3).
OBJECT-TYPE    
  OCTET STRING  

radBridgeCODCondTable 1.3.6.1.4.1.164.4.1.4.4
The table of COD Condition parameters
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeCODCondEntry

radBridgeCODCondEntry 1.3.6.1.4.1.164.4.1.4.4.1
Each radBridgeCODCondEntry consists of the following parameters
OBJECT-TYPE    
  RadBridgeCODCondEntry  

radBridgeCODCondIfIndex 1.3.6.1.4.1.164.4.1.4.4.1.1
The interface, this COD entry is applicable to.
OBJECT-TYPE    
  Integer32  

radBridgeCODOriginateConnectCondition 1.3.6.1.4.1.164.4.1.4.4.1.2
This condition, allows the user to specify the condition under which the link is connected. The options are onPowerOn - On power on. whenAnyStationOnLan - When any station on lan. onTraffic - On traffic. The user can specify the condition/s for connection. The connection will be defined in CODSpecificOnTrafficConditionOID . onManualConnect - depends on radBridgeCODManualConnect OBJECT-TYPE (=connect).
OBJECT-TYPE    
  INTEGER onPowerOn(1), whenAnyStationOnLan(2), onTraffic(3), onManualConnect(4)  

radBridgeCODOriginateDisConnectCondition 1.3.6.1.4.1.164.4.1.4.4.1.3
This condition allows the user to specify the condition under which the link is disconnected. The options are: noStationOnLan - When there is no station on lan. Counts 15 minutes from the point the last frame from lan has been received. If no frame have been transmitted on lan by the end of this period, disconnect the connection. onTraffic - On traffic. The user can specify the condition/s for disconnection. The disconnection will be defined in CODSpecificOnTrafficConditionOID . onDelayFromConnectionOnRequest - On Delay From Connection On Request . The delay time period will be defined in CODOriginateDisConnectDelay . onManualDisConnect - depends on radBridgeCODManualConnect OBJECT-TYPE (=disconnect).
OBJECT-TYPE    
  INTEGER noStationOnLan(1), onTraffic(2), onDelayFromConnectionOnRequest(3), onManualDisConnect(4)  

radBridgeCODOriginateDisConnectDelay 1.3.6.1.4.1.164.4.1.4.4.1.4
Delay time in seconds.
OBJECT-TYPE    
  Integer32  

radBridgeCODAnswerConnectCondition 1.3.6.1.4.1.164.4.1.4.4.1.5
CODCondAnswerConnect allows the user to specify the condition under which the link is connected. The options are: onPowerOn - On power on. whenAnyStationOnLan - When any station on lan. onTraffic - On traffic. The user can specify the condition/s for connection. The connection will be defined in CODSpecificOnTrafficConditionOID . onManualConnect - depends on radBridgeCODManualConnect OBJECT-TYPE .
OBJECT-TYPE    
  INTEGER onPowerOn(1), whenAnyStationOnLan(2), onTraffic(3), onManualConnect(4)  

radBridgeCODSpecificOnTrafficOIDCondition 1.3.6.1.4.1.164.4.1.4.4.1.6
A reference to a specific entry in the radBridgeMaskTable, which describes the particular COD condition . If Connect or Disconnect Conditions are not onTraffic, its value should be set to the OBJECT IDENTIFIER { 0 0 }.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

radBridgeCODDisConnectMinimunFramesNumber 1.3.6.1.4.1.164.4.1.4.4.1.7
Frames rate.
OBJECT-TYPE    
  Integer32  

radBridgeIPX 1.3.6.1.4.1.164.4.1.5
OBJECT IDENTIFIER    

radBridgeIPXdriver 1.3.6.1.4.1.164.4.1.5.1
OBJECT IDENTIFIER    

radBridgeIPXForwarding 1.3.6.1.4.1.164.4.1.5.1.1
The indication of whether this entity is acting as an IPX gateway in respect to the forwarding of datagrams received by, but not addressed to, this entity. IPX gateways forward datagrams. IPX hosts do not. Note that changing this parameter requiers RESET of the router.
OBJECT-TYPE    
  INTEGER forwarding(1), not-forwarding(2)  

radBridgeIPXRip 1.3.6.1.4.1.164.4.1.5.2
OBJECT IDENTIFIER    

radBridgeIPXRipOutPackets 1.3.6.1.4.1.164.4.1.5.2.1
The total number of packets transmitted by RIP.
OBJECT-TYPE    
  Counter32  

radBridgeIPXRipInPackets 1.3.6.1.4.1.164.4.1.5.2.2
The total number of packets received by RIP. This will include any packets that are subsequently discarded.
OBJECT-TYPE    
  Counter32  

radBridgeIPXRipInDiscards 1.3.6.1.4.1.164.4.1.5.2.3
The number of received packets discarded by RIP.
OBJECT-TYPE    
  Counter32  

radBridgeIPXRipTblNoOfEntries 1.3.6.1.4.1.164.4.1.5.2.4
The max number of entries that exist in the RIP routing table.
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipTblBcastTrigUpdateInterval 1.3.6.1.4.1.164.4.1.5.2.5
The default time interval (in seconds)between triggered RIP updates on a broadcast type interface. A triggered update occurs when a change is detected in the routing database. This time interval delays the broadcasting of these updates so that changes on the network will not result in a lot of triggered updates.
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipTable 1.3.6.1.4.1.164.4.1.5.2.6
The routing table used by RIP to calculate routes to remote desination networks.
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeIPXRipTableEntry

radBridgeIPXRipTableEntry 1.3.6.1.4.1.164.4.1.5.2.6.1
The routing information for one of this entity's destination networks.
OBJECT-TYPE    
  RadBridgeIPXRipTableEntry  

radBridgeIPXRipDestNetwork 1.3.6.1.4.1.164.4.1.5.2.6.1.1
The destination network address to which this entry's routing information pertains.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

radBridgeIPXRipPolicy 1.3.6.1.4.1.164.4.1.5.2.6.1.2
A value specifying the precidence of the route. A value of zero means that the route is the best route, a value of one means that the route is the second best route and so on.
OBJECT-TYPE    
  INTEGER main(1), alternate(2)  

radBridgeIPXRipForwardingRouter 1.3.6.1.4.1.164.4.1.5.2.6.1.3
The IPX node address of the next hop (router) for the entry's associated destination network.
OBJECT-TYPE    
  OCTET STRING SIZE(6)  

radBridgeIPXRipNIC 1.3.6.1.4.1.164.4.1.5.2.6.1.4
An interface identifier specifying what IPX interface the next hop can be found on.
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipTickMetric 1.3.6.1.4.1.164.4.1.5.2.6.1.5
The metric, in terms of transit time, associated with the route given by the entry. This time is in terms of 1/18ths of a second.
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipHopMetric 1.3.6.1.4.1.164.4.1.5.2.6.1.6
The metric, in terms of distance , associated with the route given by the entry.
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipAgingTime 1.3.6.1.4.1.164.4.1.5.2.6.1.7
The last time that the entry was updated. The time will be provided in terms of the MIB-I object sysUpTime.
OBJECT-TYPE    
  TimeTicks  

radBridgeIPXRipValueStatus 1.3.6.1.4.1.164.4.1.5.2.6.1.8
The entry status value; whether the entry is permanent (added statically), reachable or unreachable. In the latter two cases it would be added by RIP. A semiDynamic entry is an entry enterd manualy by the user and can be updated by the router.
OBJECT-TYPE    
  INTEGER static(1), dynamic(2), invalid(3), semiDynamic(4)  

radBridgeIPXRipForwardType 1.3.6.1.4.1.164.4.1.5.2.6.1.9
The type of route. Note that local(2) refers to a route for which the next hop is the final destination; remote(3) refers to a route for which the next hop is not the final destination.
OBJECT-TYPE    
  INTEGER other(1), local(2), remote(3)  

radBridgeIPXRipInfTable 1.3.6.1.4.1.164.4.1.5.2.7
The RIP interface table.
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeIPXRipInfEntry

radBridgeIPXRipInfEntry 1.3.6.1.4.1.164.4.1.5.2.7.1
Each entry corresponds to one ifindex.
OBJECT-TYPE    
  RadBridgeIPXRipInfEntry  

radBridgeIPXRipInfIfIndex 1.3.6.1.4.1.164.4.1.5.2.7.1.1
This value of Ifindex is same as radBridgeIPXIfIndex in the IPX Interface Table.
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipInfBcastUpdate 1.3.6.1.4.1.164.4.1.5.2.7.1.2
The RIP periodic update interval, in seconds. Zero value corresponds to infinite interval.
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipInfAgeMultiplier 1.3.6.1.4.1.164.4.1.5.2.7.1.3
The holding multiplier for information received in RIP periodic updates. Zero value corresponds to infinite aging time.
OBJECT-TYPE    
  Integer32  

radBridgeIPXSap 1.3.6.1.4.1.164.4.1.5.3
OBJECT IDENTIFIER    

radBridgeIPXSapOutPackets 1.3.6.1.4.1.164.4.1.5.3.1
The total number of packets transmitted by SAP.
OBJECT-TYPE    
  Counter32  

radBridgeIPXSapInPackets 1.3.6.1.4.1.164.4.1.5.3.2
The total number of packets received by SAP. This will include any packets that are subsequently discarded.
OBJECT-TYPE    
  Counter32  

radBridgeIPXSapInDiscards 1.3.6.1.4.1.164.4.1.5.3.3
The number of received packets discarded by SAP.
OBJECT-TYPE    
  Counter32  

radBridgeIPXSapTblNoOfEntries 1.3.6.1.4.1.164.4.1.5.3.4
The max number of entries that exist in the SAP Server Information table.
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapTblBcastTrigUpdateInterval 1.3.6.1.4.1.164.4.1.5.3.5
The default time interval (in seconds) between triggered SAP updates on a broadcast style interface. A triggered update occurs when a change is detected in the service database. This time interval delays the transmission of these updates so that changes on the network will not result in a lot of triggered updates.
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapTable 1.3.6.1.4.1.164.4.1.5.3.6
The Server Information table is used by SAP to store information of services which are available on the internetwork.
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeIPXSapTableEntry

radBridgeIPXSapTableEntry 1.3.6.1.4.1.164.4.1.5.3.6.1
The server information for one of this entity's server entries.
OBJECT-TYPE    
  RadBridgeIPXSapTableEntry  

radBridgeIPXSapServerType 1.3.6.1.4.1.164.4.1.5.3.6.1.1
The type of the server for which this entry pertains.
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapName 1.3.6.1.4.1.164.4.1.5.3.6.1.2
The name of the server for which this entry pertains.
OBJECT-TYPE    
  DisplayString SIZE(48)  

radBridgeIPXSapNetwork 1.3.6.1.4.1.164.4.1.5.3.6.1.3
The IPX network address of the host on which this server exists.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

radBridgeIPXSapNode 1.3.6.1.4.1.164.4.1.5.3.6.1.4
The IPX node address of the host on which this server exists.
OBJECT-TYPE    
  OCTET STRING SIZE(6)  

radBridgeIPXSapSocket 1.3.6.1.4.1.164.4.1.5.3.6.1.5
The IPX socket number that is being used by the server to which this entry pertains.
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapHopsToServer 1.3.6.1.4.1.164.4.1.5.3.6.1.6
The number of hops to the entity on which this server exists.
OBJECT-TYPE    
  Integer32 1..16  

radBridgeIPXSapNIC 1.3.6.1.4.1.164.4.1.5.3.6.1.7
An Network Interface Card identifier specifying what IPX interface the next hop can be found on.
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapAgingTime 1.3.6.1.4.1.164.4.1.5.3.6.1.8
The last time that the entry was updated. The time will be provided in terms of the MIB-I object sysUpTime.
OBJECT-TYPE    
  TimeTicks  

radBridgeIPXSapStatus 1.3.6.1.4.1.164.4.1.5.3.6.1.9
The status of the entry.
OBJECT-TYPE    
  INTEGER permanent(1), dynamic(2), invalid(3), semiDynamic(4)  

radBridgeIPXSapInfTable 1.3.6.1.4.1.164.4.1.5.3.7
The Sap interface table.
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeIPXSapInfEntry

radBridgeIPXSapInfEntry 1.3.6.1.4.1.164.4.1.5.3.7.1
Each entry corresponds to one ifindex.
OBJECT-TYPE    
  RadBridgeIPXSapInfEntry  

radBridgeIPXSapInfIfIndex 1.3.6.1.4.1.164.4.1.5.3.7.1.1
This value of Ifindex is same as radBridgeIPXIfIndex in the IPX Interface Table.
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapInfBcastUpdate 1.3.6.1.4.1.164.4.1.5.3.7.1.2
The SAP periodic update interval, in seconds. Zero value corresponds to infinite interval.
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapInfAgeMultiplier 1.3.6.1.4.1.164.4.1.5.3.7.1.3
The holding multiplier for information received in SAP periodic updates. Zero value corresponds to infinite aging time.
OBJECT-TYPE    
  Integer32  

newMasking 1.3.6.1.4.1.164.4.1.6
OBJECT IDENTIFIER    

maskingMaxEntries 1.3.6.1.4.1.164.4.1.6.1
The maximum number of entries in the masking table.
OBJECT-TYPE    
  Integer32  

maskingCurrentEntries 1.3.6.1.4.1.164.4.1.6.2
The number of entries in the mask table.
OBJECT-TYPE    
  Integer32  

maskingTable 1.3.6.1.4.1.164.4.1.6.3
This is the new masking scheme. Mask tables enable definition of forwarding restrictions and control of message flow in the internetwork. Each entry in this table defines a mask statement and an action defined by maskingOperation.
OBJECT-TYPE    
  SEQUENCE OF  
    MaskingEntry

maskingEntry 1.3.6.1.4.1.164.4.1.6.3.1
Defines the contents of each line in the mask table.
OBJECT-TYPE    
  MaskingEntry  

maskingType 1.3.6.1.4.1.164.4.1.6.3.1.1
Defines the type of mask entry.
OBJECT-TYPE    
  INTEGER tx(1), rx(2), compress(3), priority(4), loadSharing(5), facs(6), codConnect(7), codDisconnect(8)  

maskingIfIndex 1.3.6.1.4.1.164.4.1.6.3.1.2
Specifies the ifIndex of the interface to which the mask is applied.
OBJECT-TYPE    
  Integer32  

maskingIndex 1.3.6.1.4.1.164.4.1.6.3.1.3
An index to the masking table. This number should not be greater than maskingMaxEntries
OBJECT-TYPE    
  Integer32  

maskingProtocolType 1.3.6.1.4.1.164.4.1.6.3.1.4
The base protocol for masking. IPX, IP, others.
OBJECT-TYPE    
  INTEGER unknown(1), ip(2), ipx(3), sna(4), netbios(5), apple(6), dec(7), all(255)  

maskingSmartMaskOID 1.3.6.1.4.1.164.4.1.6.3.1.5
A reference to a specific Smart mask table (old radBridgeMaskTable) which enables a more specific mask type. If this information is not available, its value should be set to the OBJECT IDENTIFIER { 0 0 }.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

maskingFrameType 1.3.6.1.4.1.164.4.1.6.3.1.6
Enables the user to decide about frame type * all frame * just broadcast * just multicast.
OBJECT-TYPE    
  INTEGER unknown(1), all(2), broadcast(3), multicast(4)  

maskingFrameTypeCondition 1.3.6.1.4.1.164.4.1.6.3.1.7
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingFrameType the packet contains data that matches the content of maskingFrameType. fa lse - Condition is valid if at the position specified by maskingFrameType the packet contains data that does not match the content of maskingFrameType.
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingSourceAddress 1.3.6.1.4.1.164.4.1.6.3.1.8
The source address is according to the maskingMacOrNet and maskingProtocolType variables. In case of 'MAC' enter 6 bytes (48 bit) of source address. In case of 'NET' if the maskingProtocolType is IP, this is the IP address if the maskingProtocolType is IPX, this is the IPX address (nnnnmmmmmmss) nnnn - IPX net address mmmmmm - Node address (Mac) ss - IPX socket In case of 'Apple' nn - net address (4 nibbles) ss - socket (4 nibbles).
OBJECT-TYPE    
  GenAddress  

maskingSourceActiveBits 1.3.6.1.4.1.164.4.1.6.3.1.9
Specifies the positions of the wild card characters (*) in the maskingSourceAddress field. Only the 1's bit will be taken in considerations.
OBJECT-TYPE    
  GenAddress  

maskingSourceMacOrNet 1.3.6.1.4.1.164.4.1.6.3.1.10
The variable maskingSourceAddress and maskingSourceActiveBits will be treated as MAC, or NET address. - If maskingProtocolType = 'all', 'sna', 'netbios', dec or 'unknown', the maskingSourceMacOrNet can be macAddress only! - If maskingProtocolType = 'ip' the maskingSourceMacOrNet can be macAddress or netAddress or appleAddress. - If maskingProtocolType = 'ipx', the maskingSourceMacOrNet can be either macAddress or netAddress. - If maskingProtocolType = 'apple', the maskingSourceMacOrNet can be either macAddress or appleAddress.
OBJECT-TYPE    
  INTEGER macAddress(1), netAddress(2), ipRange(3), appleAddress(4)  

maskingSourceCondition 1.3.6.1.4.1.164.4.1.6.3.1.11
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingSourceAddress (in conjunction with maskingSourceActiveBits) the packet contains data that matches the content of maskingSourceAddress. false - Condition is valid if at the position specified by maskingSourceAddress (in conjunction with maskingSourceActiveBits) the packet contains data that does not match the content of maskingSourceAddress.
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingDestAddress 1.3.6.1.4.1.164.4.1.6.3.1.12
If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. The destination address is according to the maskingMacOrNet and maskingProtocolType variables. In case of 'MAC' enter 6 bytes (48 bit) of source address. In case of 'NET' if the maskingProtocolType is IP, this is the IP address if the maskingProtocolType is IPX, this is the IPX address (nnnnmmmmmmss) nnnn - IPX net address mmmmmm - Node address (Mac) ss - IPX socket. In case of 'Apple' nn - net address (4 nibbles) ss - socket (4 nibbles). The IPX socket entered here has priority over the value of maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, unless the entered IPX socket is don't care.
OBJECT-TYPE    
  GenAddress  

maskingDestActiveBits 1.3.6.1.4.1.164.4.1.6.3.1.13
If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. Specifies the positions of the wild card characters (*) in the maskingDestAddress field. Only the 1's bit will be taken in considerations.
OBJECT-TYPE    
  GenAddress  

maskingDestMacOrNet 1.3.6.1.4.1.164.4.1.6.3.1.14
If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. - If maskingProtocolType = 'all', 'sna', 'netbios', dec or 'unknown', the maskingDestMacOrNet can be macAddress only! - If maskingProtocolType = 'ip' the maskingDestMacOrNet can be macAddress or netAddress or appleAddress. - If maskingProtocolType = 'ipx', the maskingDestMacOrNet can be either macAddress or netAddress. - If maskingProtocolType = 'apple', the maskingDestMacOrNet can be either macAddress or appleAddress. The variable maskingDestAddress and maskingDestActiveBits will be treated as MAC, or NET address.
OBJECT-TYPE    
  INTEGER macAddress(1), netAddress(2), ipRange(3), appleAddress(4)  

maskingDestCondition 1.3.6.1.4.1.164.4.1.6.3.1.15
If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingDestAddress (in conjunction with maskingDestActiveBits) the packet contains data that matches the content of maskingDestAddress. false - Condition is valid if at the position specified by maskingDestAddress (in conjunction with maskingDestActiveBits) the packet contains data that does not match the content of maskingDestAddress.
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingLowLevelProt 1.3.6.1.4.1.164.4.1.6.3.1.16
This field is set in conjunction with the maskingProtocolType variable. This variable specifies the low level protocol. The IPX socket entered in maskingDestAddress has priority over the value of maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, unless the entered IPX socket is don't care.
OBJECT-TYPE    
  INTEGER unknown(1), ipxRip(2), ipxSap(3), ipxSpx(4), ipUdp(5), ipTcp(6), ipIcmp(7), ipxNcp(8), ipxWan(9), ipxEco(10), ipxErr(11), ipxPep(12)  

maskingLowLevelProtCondition 1.3.6.1.4.1.164.4.1.6.3.1.17
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingLowLevelProt the packet contains data that matches the content of maskingLowLevelProt. false - Condition is valid if at the position specified by maskingLowLevelProt the packet contains data that does not match the content of maskingLowLevelProt.
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingHighLevelProt 1.3.6.1.4.1.164.4.1.6.3.1.18
This field is set in connection to the maskingProtocolType variable. This variable specifies the high level protocols (application). As for today it supports just IP protocol stack. The object's value is a sum of the following instances values (selected by user): none (0), -- don't care ftp (1), ftpC (2), telnet (4), smtp (8), tftp (16), snmp (32), snmpTrap (64), ipRip (128), www (256), email (512), dns (1024), For Apple Protocol only: rtmp (2048), nbp (4096), atp (8192), aep (16384), zip (32768), adsp (65536), pap (131072), asp (262144) Example: if ftp(1), snmp(32) and snmpTrap(64) instances were selected, the value should be 97 (=1+32+64).
OBJECT-TYPE    
  Integer32  

maskingHighLevelProtCondition 1.3.6.1.4.1.164.4.1.6.3.1.19
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingHighLevelProt the packet contains data that matches the content of maskingHighLevelProt. false - Condition is valid if at the position specified by maskingHighLevelProt the packet contains data that does not match the content of maskingHighLevelProt.
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingPortNum 1.3.6.1.4.1.164.4.1.6.3.1.20
The port number is the same as in high level protocol. It specifies the dest. port in IP case or the dest. socket in case of IPX & apple protocols. IP - This object is applicable only if none (0) value was selected in maskingHighLevelProt. IPX - This object is applicable only if the socket entered in maskingDestAddress is 'don't care'(00) AND maskingLowLevelProt is NOT ipxRip or ipxSap. Apple - This option is applicable only if the socket entered in maskingDestAddress is 'don't care'(00).
OBJECT-TYPE    
  Integer32  

maskingPortNumCondition 1.3.6.1.4.1.164.4.1.6.3.1.21
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingPortNum the packet contains data that matches the content of maskingPortNum. false - Condition is valid if at the position specified by maskingPortNum the packet contains data that does not match the content of maskingPortNum. This object is applicable only when maskingPortNum is applicable.
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingOperation 1.3.6.1.4.1.164.4.1.6.3.1.22
The type of action to be taken if the frame meets the conditions of the mask. noOp = disabled (mask remains on list, but is not active) delete = mask is removed from the list. smartMask = the operation and destination of the mask will be determined by the objects of the Smart Table (old masking table: radBridgeMaskTable). If maskingType is codConnect, the 'block' value is NOT allowed. If maskingType is codDisconnect, the 'forward' value is NOT allowed.
OBJECT-TYPE    
  INTEGER block(1), forward(2), route(3), forward-route(4), high-priority(5), noOp(6), delete(7), smartMask(8)  

maskingSrcPortNum 1.3.6.1.4.1.164.4.1.6.3.1.23
The source port number. For IP: No Condition. For IPX: This object is applicable only if the socket entered in maskingSourceAddress is don't care (00) and maskingLowLevelProt is NOT ipxRip or ipxSap. For Apple:This object is applicable only if the socket entered in maskingSourceAddress is don't care (00).
OBJECT-TYPE    
  Integer32  

maskingSrcPortNumCondition 1.3.6.1.4.1.164.4.1.6.3.1.24
The same as 'maskingPortNumCondition'. Relates to source port.
OBJECT-TYPE    
  INTEGER false(1), true(2)  

radBridgePerformance 1.3.6.1.4.1.164.4.1.7
OBJECT IDENTIFIER    

radBridgeCurrentTable 1.3.6.1.4.1.164.4.1.7.1
The RAD Bridge Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeCurrentEntry

radBridgeCurrentEntry 1.3.6.1.4.1.164.4.1.7.1.1
An entry in the RAD Bridge Current table.
OBJECT-TYPE    
  RadBridgeCurrentEntry  

radBridgeCurrentIndex 1.3.6.1.4.1.164.4.1.7.1.1.1
The index of the Bridge interface. It may be ifIndex.
OBJECT-TYPE    
  Integer32  

radBridgeCurrentIngressFilteringDiscardedFrames 1.3.6.1.4.1.164.4.1.7.1.1.2
The counter associated with the number of Discarded Frames upon Ingress Filtering, encountered by a Bridge interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentFrameTypeDiscardedFrames 1.3.6.1.4.1.164.4.1.7.1.1.3
The counter associated with the number of Discarded Frames upon Frame Type and Tagging Mismatch, encountered by a Bridge interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalTable 1.3.6.1.4.1.164.4.1.7.2
The RAD Bridge Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeIntervalEntry

radBridgeIntervalEntry 1.3.6.1.4.1.164.4.1.7.2.1
An entry in the RAD Bridge Interval table.
OBJECT-TYPE    
  RadBridgeIntervalEntry  

radBridgeIntervalIndex 1.3.6.1.4.1.164.4.1.7.2.1.1
The index of the bridge interface. It may be ifIndex.
OBJECT-TYPE    
  Integer32  

radBridgeIntervalNumber 1.3.6.1.4.1.164.4.1.7.2.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist).
OBJECT-TYPE    
  Integer32 1..96  

radBridgeIntervalIngressFilteringDiscardedFrames 1.3.6.1.4.1.164.4.1.7.2.1.3
The counter associated with the number of Discarded Frames upon Ingress Filtering, encountered by a Bridge interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalFrameTypeDiscardedFrames 1.3.6.1.4.1.164.4.1.7.2.1.4
The counter associated with the number of Discarded Frames upon Frame Type and Tagging Mismatch, encountered by a Bridge interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

lanranger 1.3.6.1.4.1.164.4.2
OBJECT IDENTIFIER    

lanrangerEvents 1.3.6.1.4.1.164.4.2.0
The events for the LANRANger.
OBJECT-IDENTITY    

lanrangerLogLinkUp 1.3.6.1.4.1.164.4.2.0.1
The lanrangerLogLinkUp trap indicates that the indicated logical link is connected.
NOTIFICATION-TYPE    
  lanrangerLinkConnPhysLink  
  lanrangerLinkConnAid  

lanrangerLogLinkDown 1.3.6.1.4.1.164.4.2.0.2
The lanrangerLogLinkDown trap indicates that the indicated logical link is disconnected.
NOTIFICATION-TYPE    
  lanrangerLinkConnPhysLink  
  lanrangerLinkConnAid  

lanrangerLanTableOverflow 1.3.6.1.4.1.164.4.2.0.3
The station table has the maximum number of addresses for the LANRANger.
NOTIFICATION-TYPE    

lanrangerStatusChanged 1.3.6.1.4.1.164.4.2.0.4
The trap indicates changes in the device status .
NOTIFICATION-TYPE    
  agnLed  

lanrangerConfig 1.3.6.1.4.1.164.4.2.1
OBJECT IDENTIFIER    

lanrangerLoc 1.3.6.1.4.1.164.4.2.1.1
lanrangerLoc is set to main if the LANRANger is located on the main LAN and it is set to remote if it is located on a LAN at a remote site.
OBJECT-TYPE    
  INTEGER main(1), remote(2)  

lanrangerBurnAddress 1.3.6.1.4.1.164.4.2.1.2
This is the burned-in MacAddress on the LANRANger.
OBJECT-TYPE    
  MacAddress  

lanrangerLocAddress 1.3.6.1.4.1.164.4.2.1.3
This is a locally administered address. If a zero value appears, the network administrator did not set a locally administered address.
OBJECT-TYPE    
  MacAddress  

lanrangerActiveAddress 1.3.6.1.4.1.164.4.2.1.4
The MAC address that is in use on the LANRANger. The address selected will appear in ifPhysAddress.
OBJECT-TYPE    
  INTEGER burnedIn(1), locallyAdministered(2)  

lanrangerLearningStationTopology 1.3.6.1.4.1.164.4.2.1.5
The Learning station topology defines for the LANRANger which type of station will be inserted in the station list. The default value is permanentAndDynamic(3). dynamic(1) - Learning lan station only. permanent(2) - permanentAndDynamic(3)- Setting this parameter will reset the LANRANger . -----
OBJECT-TYPE    
  INTEGER dynamic(1), permanent(2), permanentAndDynamic(3)  

lanrangerIpRouterInfo 1.3.6.1.4.1.164.4.2.1.6
OBJECT IDENTIFIER    


lanrangerIpFastReTxLevel 1.3.6.1.4.1.164.4.2.1.6.2
The maximum buffer depth (queue length) for which lanranger will accept retransmission (for each station; the level is the same for all the stations). The valid values range is: 1..255 .
OBJECT-TYPE    
  Integer32  

lanrangerIpAgingTimeout 1.3.6.1.4.1.164.4.2.1.6.3
Ip aging time for a station - in min.
OBJECT-TYPE    
  Integer32  

lanrangerIpBootP 1.3.6.1.4.1.164.4.2.1.6.4
OBJECT IDENTIFIER    

lanrangerBootPAction 1.3.6.1.4.1.164.4.2.1.6.4.1
Activating (disable/enable) the BootP operation.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

lanrangerBootPAvailableEntries 1.3.6.1.4.1.164.4.2.1.6.4.2
The number of available entries in the BootP table.
OBJECT-TYPE    
  Integer32  

lanrangerBootPCurrentEntries 1.3.6.1.4.1.164.4.2.1.6.4.3
The current number of BootP entries in the BootP table.
OBJECT-TYPE    
  Integer32  

lanrangerBootPTable 1.3.6.1.4.1.164.4.2.1.6.4.4
A list of BootP entries. The number of entries is up to BootP current entries, according to the LANRANger model.
OBJECT-TYPE    
  SEQUENCE OF  
    LanrangerBootPEntry

lanrangerBootPEntry 1.3.6.1.4.1.164.4.2.1.6.4.4.1
BootP parameters per entry of the BootP table.
OBJECT-TYPE    
  LanrangerBootPEntry  

lanrangerBootPIpAddress 1.3.6.1.4.1.164.4.2.1.6.4.4.1.1
BootP Ip Address.
OBJECT-TYPE    
  IpAddress  

lanrangerBootPIfIndex 1.3.6.1.4.1.164.4.2.1.6.4.4.1.2
The number is the same as the ifIndex of the link.
OBJECT-TYPE    
  INTEGER notAllocated(255)  

lanrangerBootPOperation 1.3.6.1.4.1.164.4.2.1.6.4.4.1.3
This object indicates the status of this entry. active(1) - this entry is currently in use and will remain so even after the next reset of the LANRANger. delete(2) - writing this value to the object, removes the corresponding entry from the table.
OBJECT-TYPE    
  INTEGER active(1), delete(2)  

lanrangerSpoofingInfo 1.3.6.1.4.1.164.4.2.1.7
OBJECT IDENTIFIER    

lanrangerSpoofingAction 1.3.6.1.4.1.164.4.2.1.7.1
Spoofing action is applied by bit code: enable : bit 0 set (disable: bit 0 is 0) keepAlive : bit 1 ... : bit 2 and so on. For the above example, to set spoofing to keepAlive action, the object's value will be 3 = [ 2**0 + 2**1 ] Only the Remote LANRANger will accept this object ! -------
OBJECT-TYPE    
  Integer32  

lanrangerSpoofingAgingStation 1.3.6.1.4.1.164.4.2.1.7.2
Aging time of stations list, in min. The agent 'translates' the time entered in minutes, to 10 min. resolution, as follows: 1..10 min - 10 min 11..20 min - 20 min and so on... 0 is not a valid value. Only the Remote LANRANger will accept this object ! ----------------
OBJECT-TYPE    
  Integer32  

lanrangerInterface 1.3.6.1.4.1.164.4.2.2
OBJECT IDENTIFIER    

lanrangerLinkTable 1.3.6.1.4.1.164.4.2.2.1
A list of link entries. The number of entries is up to 8, according to the LANRANger model.
OBJECT-TYPE    
  SEQUENCE OF  
    LanrangerLinkEntry

lanrangerLinkEntry 1.3.6.1.4.1.164.4.2.2.1.1
LANRANger-specific parameter values for a link.
OBJECT-TYPE    
  LanrangerLinkEntry  

lanrangerLinkIndex 1.3.6.1.4.1.164.4.2.2.1.1.1
A unique value for each link, equal to the value of ifIndex. The value for each link must remain constant at least from one re-initialization of the network management agent to the next.
OBJECT-TYPE    
  Integer32  

lanrangerLinkType 1.3.6.1.4.1.164.4.2.2.1.1.2
The link type .
OBJECT-TYPE    
  INTEGER synchronous(1), asynchronous(2), x25FRconfig(3), x25FRchannel(4), isdn(5), frameRelay(6), pcmcia(7), dm2wire(8), notExist(254), unknown(255)  

lanrangerLinkState 1.3.6.1.4.1.164.4.2.2.1.1.3
The link is disabled, enabled or backup.
OBJECT-TYPE    
  INTEGER disable(2), enable(3), backup(4)  

lanrangerLinkDTRMode 1.3.6.1.4.1.164.4.2.2.1.1.4
The link DTR mode.
OBJECT-TYPE    
  INTEGER off(2), on(3), unknown(255)  

lanrangerLinkStatus 1.3.6.1.4.1.164.4.2.2.1.1.5
The link physical status .
OBJECT-TYPE    
  INTEGER ok(1), fail(2), rxNoClock(3), txProblem(4), noCarrierD(5), unknown(255)  

lanrangerLinkConnectionStatus 1.3.6.1.4.1.164.4.2.2.1.1.6
The link connection status.
OBJECT-TYPE    
  INTEGER fail(1), disconnect(2), connect(3), wait(4), down(5), trying(6), testing(7), unknown(255)  


lanrangerLinkReset 1.3.6.1.4.1.164.4.2.2.1.1.8
Setting this attribute to ON will reset the link . Upon completion the value will be set to OFF
OBJECT-TYPE    
  INTEGER off(2), on(3)  

lanrangerLinkRxMaskedFrames 1.3.6.1.4.1.164.4.2.2.1.1.9
The number of masked frames received on this physical link.
OBJECT-TYPE    
  Counter32  

lanrangerLinkLayer2Type 1.3.6.1.4.1.164.4.2.2.1.1.10
The link layer 2 type indicates whether the link is Bridge or Router and specifies the Router's type.
OBJECT-TYPE    
  INTEGER unknown(1), bridge(2), ipRouter(3), ipxRouter(4), ipAndIpxRouter(5), bRouter(6), ipBrouter(7), ipxBrouter(8), ipAndIpxBrouter(9), bridgeAndStp(10)  

lanrangerLinkLayer3Type 1.3.6.1.4.1.164.4.2.2.1.1.11
The link layer 3 type indicates the protocol type.
OBJECT-TYPE    
  INTEGER unknown(1), proprietary(2), terminalServer(3), slip(30), cSlip(31), ppp(40), rfc1490(41), hdlcFraming(42), mlPpp(43)  


wrWanThrottle 1.3.6.1.4.1.164.4.2.2.1.1.13
Throttle controls the baud rate of the WAN. For example if we have a WAN rate of 2M but we want only 1/2 M as the baud rate we set the Wan Throttle to 512k. These are the values: Full (2), 1M (3), 512k (4), 128k (5), 64k (6) Full throttle option (2) means the LAN rate.
OBJECT-TYPE    
  Integer32  

lanrangerLinkConnection 1.3.6.1.4.1.164.4.2.2.2
OBJECT IDENTIFIER    

lanrangerConnMaxEntries 1.3.6.1.4.1.164.4.2.2.2.1
The maximum number of entries in the Connection table.
OBJECT-TYPE    
  Integer32  

lanrangerConnCurrentEntries 1.3.6.1.4.1.164.4.2.2.2.2
The current number of entries in the Connection table.
OBJECT-TYPE    
  Integer32  

lanrangerLinkConnTable 1.3.6.1.4.1.164.4.2.2.2.3
A list of Connection entries. The number of entries is up to Max entries, according to the LANRANger model.
OBJECT-TYPE    
  SEQUENCE OF  
    LanrangerLinkConnEntry

lanrangerLinkConnEntry 1.3.6.1.4.1.164.4.2.2.2.3.1
Information about LANRANger Connection.
OBJECT-TYPE    
  LanrangerLinkConnEntry  


lanrangerLinkConnAid 1.3.6.1.4.1.164.4.2.2.2.3.1.2
A unique value for each logical link. The maximum number of logical links is 256, according to the LANRANger model. The value for each logical link must remain constant at least from one re-initialization of the network management agent to the next. This index is the SPS address of the logical link. noLogicLink = 65535
OBJECT-TYPE    
  Integer32  

lanrangerLinkConnMacAddr 1.3.6.1.4.1.164.4.2.2.2.3.1.3
The MAC address of the device that the logical link is connected to on the remote LAN.
OBJECT-TYPE    
  MacAddress  

lanrangerLinkConnStatus 1.3.6.1.4.1.164.4.2.2.2.3.1.4
The link connection status.
OBJECT-TYPE    
  INTEGER unknown(1), none(2), fail(3), connect(4), wait(5), down(6)  

lanrangerLinkConnDeviceType 1.3.6.1.4.1.164.4.2.2.2.3.1.5
The type of device that the logical link is connected to on the remote LAN.
OBJECT-TYPE    
  INTEGER tre1(1), tre8(2), tre1D(3), tre8D(4), tre8M(5), rrTre(6), rrTre1D(7), rrTre8D(8), iTre1(9), iTre2(10), mpTre8(11), kTre8(12), treRasA(13), treRasS(14), trePCAsync(15), trePCSync(16), mbe1(17), mbe8(18), mbe1D(19), mbe8D(20), ete8M(21), iEre1(22), iEe2(23), mpMbe8(24), kMbe8(25), mbePCAsync(26), mbePCSync(27), mbeRasA(28), mbeRasS(29), other(255)  

lanrangerLinkConnDeviceName 1.3.6.1.4.1.164.4.2.2.2.3.1.6
The logical name of the device that the logical link is connected to on the remote LAN.
OBJECT-TYPE    
  DisplayString  

lanrangerLinkConnDeviceSWVer 1.3.6.1.4.1.164.4.2.2.2.3.1.7
SW Version of the device that the logical link is connected to, on the remote LAN.
OBJECT-TYPE    
  DisplayString  

lanrangerLinkConnNumLanStation 1.3.6.1.4.1.164.4.2.2.2.3.1.8
The number of stations of the remote LAN.
OBJECT-TYPE    
  Integer32  

lanrangerLinkSyncStatus 1.3.6.1.4.1.164.4.2.2.2.3.1.9
The Sync link status.
OBJECT-TYPE    
  INTEGER synchronized(1), syncNotObtained(2), waitForSync(3), codDisconnected(4), lcp(5), ip(6), ipvj(7), ipx(8), ipIpx(9), ipvj-ipx(10), mlPpp(11), mlPpp-ip(12), mlPpp-ip-ipvj(13), mlPpp-ip-ipx(14), mlPpp-ipvj-ipx(15), mlPpp-ipx(16), frUp(17), frDown(18), dlciUp(19), dlciDown(20), extLoop(21), ipcp(22), lcpIpcp(23), redAlarm(24), yellowAlarm(26), localSyncLoss(27), remoteSyncLoss(28), networkLoop(29), networkLoopRedAlarm(30), networkLoopYelAlarm(31), networkLocSyncLoss(32), networkRemSyncLoss(33), fdlLoop(34), fdlLoopRedAlarm(35), fdlLoopYellowAlarm(36), fdlLoopLocSyncLoss(37), fdlLoopRemSyncLoss(38), loopback(39), loopbackLocSyncLoss(40), loopbackRemSyncLoss(41)  

lanrangerModemTable 1.3.6.1.4.1.164.4.2.2.3
A list of Modem entries. The number of entries is up to ifIndex.
OBJECT-TYPE    
  SEQUENCE OF  
    LanrangerModemEntry

lanrangerModemEntry 1.3.6.1.4.1.164.4.2.2.3.1
LANRANger-specific parameter values for a Modem.
OBJECT-TYPE    
  LanrangerModemEntry  

lanrangerModemLinkIndex 1.3.6.1.4.1.164.4.2.2.3.1.1
A list of asynchronous ports of the link, according to ifIndex. Synchronous ports will not appear in this table. Their port number will be skipped.
OBJECT-TYPE    
  Integer32  

lanrangerModemName 1.3.6.1.4.1.164.4.2.2.3.1.2
The Modem Name identifier for MBE/TRE. Up to 50 characters.
OBJECT-TYPE    
  DisplayString  

lanrangerModemSettingString 1.3.6.1.4.1.164.4.2.2.3.1.3
Modem setting String. Up to 80 characters.
OBJECT-TYPE    
  DisplayString  

lanrangerModemAutobaudingSpeed 1.3.6.1.4.1.164.4.2.2.3.1.4
Enable or disable autobauding. When the Autobauding feature is enabled, the MBE/TRE automatically ranges over various Baud rates, starting with 115.2 Kbps, until the correct Baud rate of the modem is detected.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

lanrangerModemResetBeforeSetup 1.3.6.1.4.1.164.4.2.2.3.1.5
Reset the modem before setup is performed. It is recommended to reset the modem before modem setup session.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

lanrangerModemAnalyzeAnswers 1.3.6.1.4.1.164.4.2.2.3.1.6
Enable this option if a modem using non-standard answering is used. When this mode is enabled, the MBE/TRE awaits modem answers 'CONNECT', 'CARRIER', or 'OK', after it transmits a modem command. Modem answers acknowledge, that a specific command has been executed. If this option is not enabled, the MBE/TRE waits for a modem answer for three seconds. If no answer has been received during this period, the MBE/TRE continues functioning as if the modem command was successfully executed. However, when dialing out, the MBE/TRE waits for one minute for connection.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

lanrangerModemSpeaker 1.3.6.1.4.1.164.4.2.2.3.1.7
Toggle the Modem Speaker On or Off .
OBJECT-TYPE    
  INTEGER off(2), on(3)  

lanrangerModemDialingNumber 1.3.6.1.4.1.164.4.2.2.3.1.8
Various command switches listed in Modem Dialing Number Menu allows selection of tone, pulse-dialing, or various wait states. P - Set Pulse dialing number . T - Set Tone dialing number . W - Wait for dialing tone before proceeding. ' - Pause for 2 seconds . @ - Wait for silence, one ring, followed by 5 sec. of silence . The Dialing Number will include both digits and letter/s of the command switches. The order and validity will be on user's responsibility. The DisplayString can have up to 40 characters.
OBJECT-TYPE    
  DisplayString  

wrLocalDialBackNumber 1.3.6.1.4.1.164.4.2.2.3.1.9
This is the number that the Remote Modem will use to call the local Modem at Dial Back. Various command switches listed in Modem Dialing Number Menu allows selection of tone, pulse-dialing, or various wait states. P - Set Pulse dialing number . T - Set Tone dialing number . W - Wait for dialing tone before proceeding. ' - Pause for 2 seconds . @ - Wait for silence, one ring, followed by 5 sec. of silence . The Dialing Number will include both digits and letter/s of the command switches. The order and validity will be on user's responsibility. The DisplayString can have up to 40 characters.
OBJECT-TYPE    
  DisplayString  

wrRingsBeforeAnswer 1.3.6.1.4.1.164.4.2.2.3.1.10
Determines which ring the modem will wait to answer the phone on.
OBJECT-TYPE    
  Integer32  

lanrangerModemDialRetries 1.3.6.1.4.1.164.4.2.2.3.1.11
The number of dialing retries requested. Default = 0
OBJECT-TYPE    
  Integer32 0..8  

lanrangerLinkPktSwTable 1.3.6.1.4.1.164.4.2.2.4
A list of X.25/FR modules entries. The number of entries is up to ifIndex.
OBJECT-TYPE    
  SEQUENCE OF  
    LanrangerLinkPktSwEntry

lanrangerLinkPktSwEntry 1.3.6.1.4.1.164.4.2.2.4.1
LANRANger-specific parameter values for X.25/FR modules.
OBJECT-TYPE    
  LanrangerLinkPktSwEntry  

lanrangerLinkPktSwIndex 1.3.6.1.4.1.164.4.2.2.4.1.1
A unique value for each X.25/FR of the link, according to numbering system of ifIndex. The maximum number of links is ifIndex. The value for each link must remain constant at least from one re-initialization of the network management agent to the next.
OBJECT-TYPE    
  Integer32  

lanrangerLinkPktSwType 1.3.6.1.4.1.164.4.2.2.4.1.2
Packet Switch Type.
OBJECT-TYPE    
  INTEGER x25FRChannel(1), x25FRConfig(2)  

lanrangerLinkPktSwControlSignal 1.3.6.1.4.1.164.4.2.2.4.1.3
Packet Switch control command.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

lanrangerLinkPktSwSpeed 1.3.6.1.4.1.164.4.2.2.4.1.4
The Pkt Switch port's speed in bits per second. Range: 1200bps .. 1544000bps
OBJECT-TYPE    
  Integer32  

lanrangerLinkPktSwConfigParity 1.3.6.1.4.1.164.4.2.2.4.1.5
The Pkt Switch Config port's character parity bit. Applicable only for x25FRConfigChannel. For x25FRChannel the value notApplicable applies.
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3), notApplicable(255)  

lanrangerLinkPktSwConfigStopBit 1.3.6.1.4.1.164.4.2.2.4.1.6
The Pkt Switch Config port's number of stop bits. Applicable only for x25FRConfigChannel. For x25FRChannel the value notApplicable applies.
OBJECT-TYPE    
  INTEGER one(1), two(2), notApplicable(255)  

lanrangerLinkPktSwResetModule 1.3.6.1.4.1.164.4.2.2.4.1.7
Reset command to Pkt Switch module. Applicable only for x25FRChannel. The command will have no effect on x25FRConfigChannel.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

wrPPPTable 1.3.6.1.4.1.164.4.2.2.5
This table contains only parameters that do not exist in the PPP standard MIBS. The table contains a list of PPP entries. The number of entries is up to ifIndex.
OBJECT-TYPE    
  SEQUENCE OF  
    WrPPPEntry

wrPPPEntry 1.3.6.1.4.1.164.4.2.2.5.1
LANRANger-specific parameter values for a PPP.
OBJECT-TYPE    
  WrPPPEntry  

wrPPPCompressionHeaderField 1.3.6.1.4.1.164.4.2.2.5.1.1
This configuration option provides a method to negotiate the compression of the Data Link Layer Address and Control fields. This configuration option is sent to inform the peer that the implementation can receive compressed Address and Control fields.
OBJECT-TYPE    
  INTEGER compressionOff(2), compressionOn(3)  

wrPPPCompressionProtocolFields 1.3.6.1.4.1.164.4.2.2.5.1.2
This configuration option provides a method to negotiate the compression of the PPP Protocol field. This configuration option is sent to inform the peer that the implementation can receive such single octet Protocol fields.
OBJECT-TYPE    
  INTEGER compressionOff(2), compressionOn(3)  

wrPPPSTACCompressionType 1.3.6.1.4.1.164.4.2.2.5.1.3
The PPP compression control protocol provides a method to negotiate and utilize compression protocol over PPP encapsulated links. These are Different types of data compression algorithm for PPP encapsulated packets.
OBJECT-TYPE    
  INTEGER disable(1), noHistory(2), lCB(3), sequence(4), extended(5)  

wrPPPAuthProtocol 1.3.6.1.4.1.164.4.2.2.5.1.4
The type of authentication protocol being used. The left parameter is the maximum authentication, the right parameter is minimum authentication.
OBJECT-TYPE    
  INTEGER noneNone(1), chapNone(2), chapPap(3), chapChap(4), papNone(5), papPap(6)  

wrPPPSecurityType 1.3.6.1.4.1.164.4.2.2.5.1.5
Type of unit.
OBJECT-TYPE    
  INTEGER host(1), guest(2)  

wrPPPUserName 1.3.6.1.4.1.164.4.2.2.5.1.6
PPP User name.
OBJECT-TYPE    
  SnmpAdminString SIZE(0..10)  

wrPPPPassword 1.3.6.1.4.1.164.4.2.2.5.1.7
PPP Password .
OBJECT-TYPE    
  SnmpAdminString SIZE(0..10)  

wrPPPLinkActiveTime 1.3.6.1.4.1.164.4.2.2.5.1.8
PPP link active time in seconds Values range: 2 - 900. Default value = 2
OBJECT-TYPE    
  Integer32  

lanrangerStation 1.3.6.1.4.1.164.4.2.3
OBJECT IDENTIFIER    

lanrangerStationTable 1.3.6.1.4.1.164.4.2.3.1
A table that contains information about the stations on the remote LAN(s). A remote LANRANger contains a list of stations on its LAN, while a main LANRANger contains a list of stations at all the remote sites it is connected to.
OBJECT-TYPE    
  SEQUENCE OF  
    LanrangerStationEntry

lanrangerStationEntry 1.3.6.1.4.1.164.4.2.3.1.1
Information about a specific station, that the LANRANger lists as being on a remote LAN.
OBJECT-TYPE    
  LanrangerStationEntry  



lanrangerStationAddress 1.3.6.1.4.1.164.4.2.3.1.1.3
The unicast MAC address of a station that the LANRANger lists as being on a remote LAN.
OBJECT-TYPE    
  MacAddress  

lanrangerStationStatus 1.3.6.1.4.1.164.4.2.3.1.1.4
The status of this entry. The meanings of the values are: unknown(1) : learned(2) : the value of the corresponding instance of lanrangerStationAddress was learned and is being used. self(3) : the value of the corresponding instance of lanrangerStationAddress represents the LANRANger's address. static(4) : the value of the corresponding instance of lanrangerStationAddress is also the value of an existing instance of lanrangerStaticAddress.
OBJECT-TYPE    
  INTEGER unknown(1), learned(2), self(3), static(4)  

lanrangerStationSpoofingStatus 1.3.6.1.4.1.164.4.2.3.1.1.5
The spoofing status of this entry.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

lanrangerLanMaxStations 1.3.6.1.4.1.164.4.2.3.2
The maximum number of stations in the station table.
OBJECT-TYPE    
  Integer32  

lanrangerLanCurrentStations 1.3.6.1.4.1.164.4.2.3.3
The current number of stations in the station table.
OBJECT-TYPE    
  Integer32  

lanrangerPermanentStation 1.3.6.1.4.1.164.4.2.3.4
OBJECT IDENTIFIER    

lanrangerPermanentMaxEntries 1.3.6.1.4.1.164.4.2.3.4.1
The maximum number of entries in the permanent stations table.
OBJECT-TYPE    
  Integer32  

lanrangerPermanentCurrentEntries 1.3.6.1.4.1.164.4.2.3.4.2
The current number of entries in the permanent stations table.
OBJECT-TYPE    
  Integer32  

lanrangerPermanentTable 1.3.6.1.4.1.164.4.2.3.4.3
A table containing address information configured into the LANRANger by (local or network) management, specifying addresses on a remote LAN. This table objects can be set only on a Remote LANRANger.
OBJECT-TYPE    
  SEQUENCE OF  
    LanrangerPermanentEntry

lanrangerPermanentEntry 1.3.6.1.4.1.164.4.2.3.4.3.1
Address information configured into the remote LANRANger by (local or network) management specifying addresses on a remote LAN.
OBJECT-TYPE    
  LanrangerPermanentEntry  

lanrangerPermanentIfIndex 1.3.6.1.4.1.164.4.2.3.4.3.1.1
The number of the physical link that is connected to the remote LAN, on which the station with the associated instance of lanrangerStationAddress is located. The number is the same as the ifIndex of the link. This data is interesting for main LANRANger only.
OBJECT-TYPE    
  Integer32  


lanrangerPermanentAddress 1.3.6.1.4.1.164.4.2.3.4.3.1.3
The MAC address entered by management to this entry. Only the remote LANRANger will accept Set for this object ! ----------------
OBJECT-TYPE    
  MacAddress  

lanrangerPermanentOperation 1.3.6.1.4.1.164.4.2.3.4.3.1.4
This object indicates the status of this entry. active(1) - this entry is currently in use and will remain so even after the next reset of the LANRANger. delete(2) - writing this value to the object removes the corresponding entry. Only the remote LANRANger will accept Set for this object ! ----------------
OBJECT-TYPE    
  INTEGER active(1), delete(2)  

lanrangerIpStation 1.3.6.1.4.1.164.4.2.3.5
OBJECT IDENTIFIER    

lanrangerIpPermanentAvailableEntries 1.3.6.1.4.1.164.4.2.3.5.1
The available number of entries in the IP permanent stations table.
OBJECT-TYPE    
  Integer32  

lanrangerIpPermanentCurrentEntries 1.3.6.1.4.1.164.4.2.3.5.2
The current number of entries in the IP permanent station table.
OBJECT-TYPE    
  Integer32  

lanrangerSpoofingStation 1.3.6.1.4.1.164.4.2.3.6
OBJECT IDENTIFIER    

lanrangerSpoofingMaxEntries 1.3.6.1.4.1.164.4.2.3.6.1
The maximum number of entries in the Spoofing station table.
OBJECT-TYPE    
  Integer32  

lanrangerSpoofingCurrentEntries 1.3.6.1.4.1.164.4.2.3.6.2
The current number of entries in the Spoofing station table.
OBJECT-TYPE    
  Integer32  

lanrangerSpoofingTable 1.3.6.1.4.1.164.4.2.3.6.3
A list of Spoofing entries. The number of entries is up to the current number of entries, according to the LANRANger model. Only the LOCAL LANRANger will show this table ! ---------------
OBJECT-TYPE    
  SEQUENCE OF  
    LanrangerSpoofingEntry

lanrangerSpoofingEntry 1.3.6.1.4.1.164.4.2.3.6.3.1
Spoofing parameters per entry of the Spoofing table.
OBJECT-TYPE    
  LanrangerSpoofingEntry  

lanrangerSpoofingGroup 1.3.6.1.4.1.164.4.2.3.6.3.1.1
The spoofing group. Only the LOCAL Lanranger will show this table !
OBJECT-TYPE    
  Integer32  

lanrangerSpoofingMacAddress 1.3.6.1.4.1.164.4.2.3.6.3.1.2
MAC Address of the Remote Lanrangers. Only the LOCAL Lanranger will show this table !
OBJECT-TYPE    
  MacAddress  

lanrangerSpoofingAging 1.3.6.1.4.1.164.4.2.3.6.3.1.3
Aging time defined for a whole group, in minutes. Only the LOCAL Lanranger will show this table !
OBJECT-TYPE    
  Integer32  

lanrangerSpoofingTimeLeft 1.3.6.1.4.1.164.4.2.3.6.3.1.4
Time until aging expires, per station, in minutes. Only the LOCAL Lanranger will show this table !
OBJECT-TYPE    
  Integer32  

trim 1.3.6.1.4.1.164.4.3
OBJECT IDENTIFIER    

trimInterface 1.3.6.1.4.1.164.4.3.1
OBJECT IDENTIFIER    

trimIfTable 1.3.6.1.4.1.164.4.3.1.1
RAD-specific interface table.
OBJECT-TYPE    
  SEQUENCE OF  
    TrimIfEntry

trimIfEntry 1.3.6.1.4.1.164.4.3.1.1.1
An entry in table trimIfTable.
OBJECT-TYPE    
  TrimIfEntry  

trimIfIndex 1.3.6.1.4.1.164.4.3.1.1.1.1
Index to the Trimbridge Interface Table. The interface defined by a particular value of this index is the same interface as identified by the same value of ifIndex (MIB II).
OBJECT-TYPE    
  Integer32  

trimIfBoardNum 1.3.6.1.4.1.164.4.3.1.1.1.2
Reserved for possible future use. Not currently applicable to Trimbridge.
OBJECT-TYPE    
  Integer32  

trimIfNetAddress 1.3.6.1.4.1.164.4.3.1.1.1.3
The IP address of the interface defined by the particular value of trimIfIndex.
OBJECT-TYPE    
  IpAddress  

trimIfStatus 1.3.6.1.4.1.164.4.3.1.1.1.4
The current status of the interface. Some of these status values are not applicable to Trimbridge.
OBJECT-TYPE    
  INTEGER ok(1), okSingleBrg(2), okMultiBrg(3), connctFault(4), rxFault(5), txFault(6), channelLoopback(7), rxClockFault(8), t1Alarm(9)  

trimIfClockType 1.3.6.1.4.1.164.4.3.1.1.1.5
trimIfClockType defines the type of clock each interface uses: internal or external.
OBJECT-TYPE    
  INTEGER external(1), internal(2), t1(3), g703(4)  

trimIfBaudRate 1.3.6.1.4.1.164.4.3.1.1.1.6
Defines the baud rate in use by the interface. The valid rates are determined by the type of the media for which this baud rate is defined.
OBJECT-TYPE    
  Integer32  

trimIfCost 1.3.6.1.4.1.164.4.3.1.1.1.7
This object is inapplicable to Trimbridge.
OBJECT-TYPE    
  Integer32  

trimIfCompression 1.3.6.1.4.1.164.4.3.1.1.1.8
Defines whether data compression is enabled or disabled for the interface.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

trimIfCompressionStatus 1.3.6.1.4.1.164.4.3.1.1.1.9
Defines the status of the compression component: not-inserted - compression component is not in the device active - compression is enabled and operates correctly not-active - compression is enables but does not operate. The reason may be that there is no compression component on the device connected to this interface. disabled - compression was disabled by management, using variable trimCompression.
OBJECT-TYPE    
  INTEGER not-inserted(1), active(2), not-active(3), disable(4)  

trimIfCompressionRate 1.3.6.1.4.1.164.4.3.1.1.1.10
Percentage of compression. This variable applies only if trimCompressionStatus is active.
OBJECT-TYPE    
  Integer32  

trimIfLATCompression 1.3.6.1.4.1.164.4.3.1.1.1.11
Enable/Disable the LAT Compression.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

trimIfCompressionType 1.3.6.1.4.1.164.4.3.1.1.1.12
This parameter indicates the type of compression option available in the device. `None(1) - indicates that there is no compression option in the device lowSpeed(2) - indicates a compression option which is operational up to line speed sof 64 kbps. highSpeed(3) - indicates a compression option which is operational up to line speeds of 2 Mbps.
OBJECT-TYPE    
  INTEGER none(1), lowSpeed(2), highSpeed(3)  

trimIfFilterMode 1.3.6.1.4.1.164.4.3.1.1.1.13
This parameter indicates the type of filtering in the device.
OBJECT-TYPE    
  INTEGER destinationOnly(1), sourceAndDestination(2)  

trimIfConType 1.3.6.1.4.1.164.4.3.1.1.1.14
This parameter indicates the connector type of an interface.
OBJECT-TYPE    
  INTEGER unknown(1), none(2), x21Old(3), x21(4), v35Old(5), v35(6), rs530Old(7), rs530(8), rs232Old(9), rs232(10), spsV35(11), spsRS530(12), spsRS232(13), spsX21(14), isdn(15)  

trimIfRemAddress 1.3.6.1.4.1.164.4.3.1.1.1.15
OBJECT-TYPE    
  DisplayString SIZE(1..17)  

trimIfLocSubAddress 1.3.6.1.4.1.164.4.3.1.1.1.16
Space is not valid. If the string includes a space, the whole entry is considered not valid.
OBJECT-TYPE    
  DisplayString SIZE(1..6)  

trimIfRemSubAddress 1.3.6.1.4.1.164.4.3.1.1.1.17
Space is not valid. If the string includes a space, the whole entry is considered not valid.
OBJECT-TYPE    
  DisplayString SIZE(1..6)  

trimIfCLIVerification 1.3.6.1.4.1.164.4.3.1.1.1.18
Enables/Disables verification of Control Line Identification (CLI)
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

trimRS232Conf 1.3.6.1.4.1.164.4.3.1.2
OBJECT IDENTIFIER    

trimBaudRate 1.3.6.1.4.1.164.4.3.1.2.1
Selects the baud rate used by the RS232 management interface. The default selection is 1200 bits/second.
OBJECT-TYPE    
  INTEGER br300(1), br1200(2), br2400(5), br4800(7), br9600(9), br19200(10)  

trimParity 1.3.6.1.4.1.164.4.3.1.2.2
Determines whether the parity bit will be used and determines its type.
OBJECT-TYPE    
  INTEGER noParity(1), oddParity(2), evenParity(3)  

trimStopBit 1.3.6.1.4.1.164.4.3.1.2.3
Selects the number of stop bits appended to the end of each data word.
OBJECT-TYPE    
  INTEGER oneStopBit(1), twoStopBit(2)  

trimThresholdRep 1.3.6.1.4.1.164.4.3.1.3
OBJECT IDENTIFIER    

trimIfThresholdRepTable 1.3.6.1.4.1.164.4.3.1.3.1
.....
OBJECT-TYPE    
  SEQUENCE OF  
    TrimIfThresholdRepEntry

trimIfThresholdRepEntry 1.3.6.1.4.1.164.4.3.1.3.1.1
An entry in table trimIfThresholdRepTable.
OBJECT-TYPE    
  TrimIfThresholdRepEntry  

trimIfThreRepId 1.3.6.1.4.1.164.4.3.1.3.1.1.1
The Interface number serves as an index to the Threshold Reoprt Table.
OBJECT-TYPE    
  Integer32  

trimIfThreRepCounterId 1.3.6.1.4.1.164.4.3.1.3.1.1.2
The Counter ID serves as an index to the Threshold Reoprt Table, and identify the counter for which to pot the threshold.
OBJECT-TYPE    
  INTEGER vot(1)  

trimThresholdValue 1.3.6.1.4.1.164.4.3.1.3.1.1.3
The Threshold value , this is the maximum rate of counter increments before the element issue trap.
OBJECT-TYPE    
  Integer32  

trimIfThreRepSampleRate 1.3.6.1.4.1.164.4.3.1.3.1.1.4
The network object will sample the counter atthis interval. When this parameter is set to 0, the treshold comparison is disable.
OBJECT-TYPE    
  Integer32  

trimIfThreRepTrapRate 1.3.6.1.4.1.164.4.3.1.3.1.1.5
The network object will issue a trap according to this interval. Note that the trape interval nust be equal or larger then trimIfThreRepSampleRate.
OBJECT-TYPE    
  Integer32  

trimBackup 1.3.6.1.4.1.164.4.3.2
OBJECT IDENTIFIER    

trimBackupState 1.3.6.1.4.1.164.4.3.2.1
If main - the bridge is connected via the main physical link. If backup - the automatic backup feature was enabled and the bridge is connected via the backup physical link.
OBJECT-TYPE    
  INTEGER main(1), backup(2)  

trimDialUpStatus 1.3.6.1.4.1.164.4.3.2.2
This parameter controls the operation of dial-up backup function. If status is disable(2), dial-up backup will not be initiated when the main link fails or exceeds the specified error limit. If status is enable(1), the dial-up backup will be initiated if the main link fails or if the error rate on the main link exceeds the limit specified by variable trimDialUp ErrorThreshold.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

trimBackLinkType 1.3.6.1.4.1.164.4.3.2.3
This variable specifies the type of the backup link. If the type is leased(2), Trimbridge will reroute traffic to the backup link, when main link fails. If the value is dialUp(1), then the backup dial-up procedure is initiated when the main link fails.
OBJECT-TYPE    
  INTEGER dialUp(1), leased(2)  

trimDialUpMode 1.3.6.1.4.1.164.4.3.2.4
If the mode is originate(1), Trimbridge initiates the backup procedure when the main link fails. if the mode is answer(2), it expects that the bridge on the other end of the link will initiate the backup procedure. Note that only one bridge in a pair should be set to mode originate(1).
OBJECT-TYPE    
  INTEGER originate(1), answer(2)  

trimDialUpErrorThreshold 1.3.6.1.4.1.164.4.3.2.5
Error rate on main link at which Backup will be enabled. low - 1*10-5 medium - 5*10-4 high - 1*10-3 If none(1) is selected, then backup is not invoked when there are errors on the main link, but only when the main link is down.
OBJECT-TYPE    
  INTEGER none(1), low(2), medium(3), high(4)  

trimDialUpRedialTimeout 1.3.6.1.4.1.164.4.3.2.6
If an attempt to dial up failed for the specified time, a new redial attempt will be initiated.
OBJECT-TYPE    
  Integer32  

trimDialUpRedialNum 1.3.6.1.4.1.164.4.3.2.7
This variable specifies the number of times to initiate the dial-up procedure. If the number of redials is set to zero (0), then the number of redials will be unlimited. Any other value will cause the dial-up procedure to terminate after the specified number of re-dial attempts fail. Resetting this variable to any value will re-initiate the dial-up procedure.
OBJECT-TYPE    
  Integer32  

trimBackUpConnectDelay 1.3.6.1.4.1.164.4.3.2.8
The connect delay defines the minimum time period that the link must be disconnected.
OBJECT-TYPE    
  Integer32  

trimBackUpDisConnectDelay 1.3.6.1.4.1.164.4.3.2.9
The disconnect delay defines the delay between the last valid traffic trigger and link disconnection.
OBJECT-TYPE    
  Integer32  

trimBackUpScheduleTable 1.3.6.1.4.1.164.4.3.2.10
This is a table that contains the reroute shedule for the backup link. The index is the day of the week, starting with 1 for Sunday, ending with 7 for Saturday.
OBJECT-TYPE    
  SEQUENCE OF  
    TrimBackUpEntry

trimBackUpEntry 1.3.6.1.4.1.164.4.3.2.10.1
An entry in table trimBackUpScheduleTable.
OBJECT-TYPE    
  TrimBackUpEntry  

trimBackUpDay 1.3.6.1.4.1.164.4.3.2.10.1.1
The day of the week for which the entry applies. The days are numbered from 1 to 7, representing Monday through Sunday.
OBJECT-TYPE    
  Integer32  

trimBackUpFromTo 1.3.6.1.4.1.164.4.3.2.10.1.2
This is the time during which backup should be disabled, expressed as xx:xx-yy:yy, where x's reflect the time from and y's reflect the time to. The first two digits, in x and in y, are the hour and the second two digits are the minutes. The pairs of digits are separated by a colon, and the x is separated from the y by a dash.
OBJECT-TYPE    
  DisplayString  

trimBackUpDelayAfterFailure 1.3.6.1.4.1.164.4.3.2.11
This entry defines the delay between the last @@@@
OBJECT-TYPE    
  Integer32  

trimTR 1.3.6.1.4.1.164.4.3.3
OBJECT IDENTIFIER    

trimTRIfTable 1.3.6.1.4.1.164.4.3.3.1
This table defines configuration parameters for Token Ring interfaces in the Trimbridge-16.
OBJECT-TYPE    
  SEQUENCE OF  
    TrimTRIfEntry

trimTRIfEntry 1.3.6.1.4.1.164.4.3.3.1.1
An entry in table trimTRIfTable.
OBJECT-TYPE    
  TrimTRIfEntry  

trimTRIfIndex 1.3.6.1.4.1.164.4.3.3.1.1.1
Index to the Token Ring Interface Table. The interface defined by a particular value of this index is the same interface as identified by the same value of ifIndex (MIBII).
OBJECT-TYPE    
  Integer32  

trimTREarlyTokenRelease 1.3.6.1.4.1.164.4.3.3.1.1.2
This parameter controls the early token release. This paramenter is applicable only to 16 Mbps rings.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

trimTRLocalAdminAddress 1.3.6.1.4.1.164.4.3.3.1.1.3
A locally administered MAC Address of this interface.
OBJECT-TYPE    
  MacAddress  

trimTRLocalAdminAddressStatus 1.3.6.1.4.1.164.4.3.3.1.1.4
This parameter controls whether the bridge uses the locally administered MAC Address defined for this interface, when enable(1), or not , when disable(2).
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

trimTrapInfo 1.3.6.1.4.1.164.4.3.4
OBJECT IDENTIFIER    

trimErrorDesc 1.3.6.1.4.1.164.4.3.4.1
A textual description of the enterprise-specific trap sent to the Network Management Station by Trimbridge.
OBJECT-TYPE    
  DisplayString  

trimErrorSeverity 1.3.6.1.4.1.164.4.3.4.2
The severity type of the enterprise-specific trap sent to the Network Management Station by Trimbridge.
OBJECT-TYPE    
  INTEGER information(1), warning(2), error(3), fatal(4)  

febFtb 1.3.6.1.4.1.164.4.4
OBJECT IDENTIFIER    

febFtbEvents 1.3.6.1.4.1.164.4.4.0
The events for FEBs and FTBs.
OBJECT-IDENTITY    

lanTableOverflow 1.3.6.1.4.1.164.4.4.0.1
The station table has the maximum number of addresses for the device.
NOTIFICATION-TYPE    

statusChanged 1.3.6.1.4.1.164.4.4.0.2
A change occured in agent status or leds.
NOTIFICATION-TYPE    
  agnLed  
  agnIndication  

portFddiStatusChanged 1.3.6.1.4.1.164.4.4.0.3
The Fddi port status changed. fddimibPORTPCMState value has become off, maint, active, connect, or exited one of these states.
NOTIFICATION-TYPE    
  fddimibPORTPCMState  
  agnLed  

febFtbTranslation 1.3.6.1.4.1.164.4.4.1
OBJECT IDENTIFIER    

febFtbTranslIfTable 1.3.6.1.4.1.164.4.4.1.1
The translation table defines which type of translation is required for each device interface. This is particularly important for WAN links, as the translating device does not have a knowledge of the target LAN type.
OBJECT-TYPE    
  SEQUENCE OF  
    FebFtbTranslIfEntry

febFtbTranslIfEntry 1.3.6.1.4.1.164.4.4.1.1.1
Entry in the translation table.
OBJECT-TYPE    
  FebFtbTranslIfEntry  

febFtbTranslIfIndex 1.3.6.1.4.1.164.4.4.1.1.1.1
Index to the Translation Table. The interface defined by a particular value of this index is the same interface as identified by the same value of ifIndex (MIBII).
OBJECT-TYPE    
  Integer32  

febFtbTunnelProtocol 1.3.6.1.4.1.164.4.4.1.1.1.2
IEEE 802.1h standard defines the tunneling for Appletalk I. This parameter enables the user to specify Ethertype of an additional protocol to tunnel (e.g. IPX). For IPX, Enter 8137 to translate Token Ring SNAP frames to Ethernet_SNAP frames (instead of Ethernet II). Valid range of values: 05DC to FFFF (hex) 0000 (hex) - disables this function.
OBJECT-TYPE    
  OCTET STRING SIZE(2)  

febFtbTranslIPXRawEthernet 1.3.6.1.4.1.164.4.4.1.1.1.3
This variable defines the translation mode for IPX frames in standrad Token Ring format. It is applicable to Ethernet interfaces (i.e. febFtbTranslSwitch variable has value Ethernet (2). ). ethernetRaw8023: translate to Raw Ethernet frames (default) ethernet8022: translate to Ethernet 802.2 frames.
OBJECT-TYPE    
  INTEGER ethernetRaw8023(1), ethernet8022(2)  

febFtbStatus 1.3.6.1.4.1.164.4.4.2
OBJECT IDENTIFIER    

febFtbLanTable 1.3.6.1.4.1.164.4.4.2.1
.
OBJECT-TYPE    
  SEQUENCE OF  
    FebFtbLanTabEntry

febFtbLanTabEntry 1.3.6.1.4.1.164.4.4.2.1.1
Entry in the LanTab table.
OBJECT-TYPE    
  FebFtbLanTabEntry  

febFtbLanTabIfIndex 1.3.6.1.4.1.164.4.4.2.1.1.1
This variable defines the related interface
OBJECT-TYPE    
  Integer32  

febFtbLanTabEntNumber 1.3.6.1.4.1.164.4.4.2.1.1.2
This variable defines the number of entries in the LAN table reletaed to the specific interface
OBJECT-TYPE    
  Integer32  

febFtbFaults 1.3.6.1.4.1.164.4.4.2.2
This variable defines the current device faults. It is a 32 bits variable, where each bit represents a unique fault
OBJECT-TYPE    
  Integer32  

mlb 1.3.6.1.4.1.164.4.5
OBJECT IDENTIFIER    

mlbEvents 1.3.6.1.4.1.164.4.5.0
The events for the MLB.
OBJECT-IDENTITY    

mlbLanTableOverflow 1.3.6.1.4.1.164.4.5.0.1
The station table has the maximum number of addresses for the LANRANger.
NOTIFICATION-TYPE    

mlbStatusChanged 1.3.6.1.4.1.164.4.5.0.2
The trap indicates changes in the device status .
NOTIFICATION-TYPE    
  agnLed  

mlbConfig 1.3.6.1.4.1.164.4.5.1
OBJECT IDENTIFIER    

mlbMibVersion 1.3.6.1.4.1.164.4.5.1.1
mlb private mib version .
OBJECT-TYPE    
  OCTET STRING  

mlbPanelMedia 1.3.6.1.4.1.164.4.5.1.2
The panel media. It can be fiber optic connector or STP+UTP in case of copper
OBJECT-TYPE    
  INTEGER unknown(1), copper(2), fiberOptic(3), notSupported(4)  

mlbRRFrontPanelPort 1.3.6.1.4.1.164.4.5.1.3
Front panel port function : MainPort / Sec.Port (case of RADring card) .
OBJECT-TYPE    
  INTEGER unknown(1), secondary(2), main(3), notSupported(4)  

mlbRRTermination 1.3.6.1.4.1.164.4.5.1.4
Temination switch - Split back lan and Terminate it. (case of RADring card) .
OBJECT-TYPE    
  INTEGER unknown(1), on(2), off(3), notSupported(4)  

mlbAddress 1.3.6.1.4.1.164.4.5.2
OBJECT IDENTIFIER    

mlbAddressTable 1.3.6.1.4.1.164.4.5.2.1
A table that contains information about the MLB ports address .
OBJECT-TYPE    
  SEQUENCE OF  
    MlbAddressEntry

mlbAddressEntry 1.3.6.1.4.1.164.4.5.2.1.1
Information about a specific port that the MLB lists define.
OBJECT-TYPE    
  MlbAddressEntry  

mlbPortIndex 1.3.6.1.4.1.164.4.5.2.1.1.1
A unique value for each port, equal to the value of ifIndex for the port. The maximum number of ports for mlb is 2 .
OBJECT-TYPE    
  Integer32  

mlbBurnAddress 1.3.6.1.4.1.164.4.5.2.1.1.2
This is the burned-in MacAddress on the LANRANger.
OBJECT-TYPE    
  MacAddress  

mlbLocAddress 1.3.6.1.4.1.164.4.5.2.1.1.3
This is a locally administered address. If a zero value appears, the network administrator did not set a locally administered address.
OBJECT-TYPE    
  MacAddress  

mlbActiveAddress 1.3.6.1.4.1.164.4.5.2.1.1.4
The MAC address that is in use on the LANRANger. The address selected will appear in ifPhysAddress.
OBJECT-TYPE    
  INTEGER burnedIn(1), locallyAdministered(2)  

radConverters 1.3.6.1.4.1.164.5
OBJECT IDENTIFIER    

genSnar 1.3.6.1.4.1.164.5.1
OBJECT IDENTIFIER    

snarState 1.3.6.1.4.1.164.5.1.1
OBJECT IDENTIFIER    

snarStatus 1.3.6.1.4.1.164.5.1.1.1
The status of the whole SNAR process 1 -up 2 -down 3 -test (After setting one of the previous states, the status will be test until the changes will be done).
OBJECT-TYPE    
  INTEGER up(1), down(2), test(3)  

snarBufferUsage 1.3.6.1.4.1.164.5.1.1.2
The buffer usage of the SNAR (in percentage).
OBJECT-TYPE    
  Integer32 0..100  

snarMaxSnaSession 1.3.6.1.4.1.164.5.1.1.3
Max number of sessions supported in this SNAR implementation
OBJECT-TYPE    
  Integer32  

snarSaveChanges 1.3.6.1.4.1.164.5.1.1.5
N/A to SNAR, only for devices. When changes are made to any configuration parameters (SNA, NVA or others) it should be stored in the device's NVRAM and then the device is restarted. Using this variable the manager can: 2 - Just save into NVRAM all configuration changes 3 - Save into NVRAM the configuration changes and restart the Device, to reflect the changes. 4 - Undo all changes since last reset or save, (without resetting the device). Load the original configuration from the NVRAM.
OBJECT-TYPE    
  INTEGER noSave(1), save(2), saveAndReset(3), undoAllChanges(4)  

snarNva 1.3.6.1.4.1.164.5.1.3
OBJECT IDENTIFIER    

nvaAgentsNumber 1.3.6.1.4.1.164.5.1.3.2
The number of configured NetView agents
OBJECT-TYPE    
  Counter32  

nvaAgentTable 1.3.6.1.4.1.164.5.1.3.3
OBJECT-TYPE    
  SEQUENCE OF  
    NvaAgentEntry

nvaAgentEntry 1.3.6.1.4.1.164.5.1.3.3.1
An entry in table nvaAgentTable.
OBJECT-TYPE    
  NvaAgentEntry  

nvaAgIndex 1.3.6.1.4.1.164.5.1.3.3.1.1
Agent number . Range (1 - nvaAgentsNumber)
OBJECT-TYPE    
  Integer32  

nvaAgAdminStatus 1.3.6.1.4.1.164.5.1.3.3.1.3
The admin. status of NV AGENT. Value of 'disable' will prevent the NetView agent from trying to connect to the NetView management system
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

nvaAgOperState 1.3.6.1.4.1.164.5.1.3.3.1.4
Current Operation state of the NetView agent. Active state means that the NetView agent is in session with the NetView management system
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

nvaAgFilter 1.3.6.1.4.1.164.5.1.3.3.1.5
Alert filter bit mask. Each bit corresponds to a specific alert sent by the NetView agent.
OBJECT-TYPE    
  OCTET STRING  

nvaAgAllowRunCmd 1.3.6.1.4.1.164.5.1.3.3.1.6
Defines whether the NetView agent is allowed to handle operational commands, received by the RUNCMD facility
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

nvaAgAccessType 1.3.6.1.4.1.164.5.1.3.3.1.7
Defines the method in which the agent tries to connect to the NetView management system(the SNA host)
OBJECT-TYPE    
  INTEGER llcCsmacd(1), llcTokenRing(3), sdlc(6), qllcX25(10)  

nvaAgIfIndex 1.3.6.1.4.1.164.5.1.3.3.1.8
The port number of the interface in which the NetView agent connects to the SNA host
OBJECT-TYPE    
  Integer32  

nvaAgXidBlockId 1.3.6.1.4.1.164.5.1.3.3.1.9
The BLOCKID part of the XID information which the NetView agent should use to connect to the NetView management system (The SNA host)
OBJECT-TYPE    
  OCTET STRING SIZE(2)  

nvaAgXidBlockNum 1.3.6.1.4.1.164.5.1.3.3.1.10
The BLOCKNUM part of the XID information which the NetView agent should use to connect to the NetView management system (The SNA host)
OBJECT-TYPE    
  OCTET STRING SIZE(3)  

nvaAgSSap 1.3.6.1.4.1.164.5.1.3.3.1.11
Local SAP, used for the NetView session - for LLC access type session only.
OBJECT-TYPE    
  Sap  

nvaAgDSap 1.3.6.1.4.1.164.5.1.3.3.1.12
Remote(host) Sap used by the NetView agent for the SNA host connection - for LLC access session type only.
OBJECT-TYPE    
  Sap  

nvaAgRemMacAddr 1.3.6.1.4.1.164.5.1.3.3.1.13
Remote(host) MAC address used by the NetView agent for the SNA host connection - for LLC access session type only.
OBJECT-TYPE    
  MacAddress  

nvaAgSdlcAddr 1.3.6.1.4.1.164.5.1.3.3.1.14
SDLC address used by the NetView agent for the SNA host connection - for SDLC access session type only.
OBJECT-TYPE    
  SdlcAddr  

nvaAgResourceName 1.3.6.1.4.1.164.5.1.3.3.1.15
A 4 character name that is appended to the resource name in the NetView alerts sent by the NetView agent
OBJECT-TYPE    
  DisplayString  

nvaAgentStatTable 1.3.6.1.4.1.164.5.1.3.4
OBJECT-TYPE    
  SEQUENCE OF  
    NvaAgentStatEntry

nvaAgentStatEntry 1.3.6.1.4.1.164.5.1.3.4.1
An entry in table nvaAgentStatTable.
OBJECT-TYPE    
  NvaAgentStatEntry  

nvaAgStatIndex 1.3.6.1.4.1.164.5.1.3.4.1.1
Agent number . Range (1 - nvaAgentsNumber)
OBJECT-TYPE    
  Integer32  

nvaAgStatTime 1.3.6.1.4.1.164.5.1.3.4.1.2
Time since last reset of the NV agent statistics. Setting to a value of 0 will clear all Agents' statistics.
OBJECT-TYPE    
  TimeTicks  

nvaAgActPu 1.3.6.1.4.1.164.5.1.3.4.1.3
Number of session initiation (ACTPU) requests received from the SNA host
OBJECT-TYPE    
  Counter32  

nvaAgDactPu 1.3.6.1.4.1.164.5.1.3.4.1.4
Number of session disconnection (DACTPU) requests received from the SNA host
OBJECT-TYPE    
  Counter32  

nvaAgRpNmvt 1.3.6.1.4.1.164.5.1.3.4.1.5
Number of NMVTs received from the SNA host, and responded with a positive response.
OBJECT-TYPE    
  Counter32  

nvaAgRnNmvt 1.3.6.1.4.1.164.5.1.3.4.1.6
Number of NMVTs received from the SNA host, and respond with a negative response.
OBJECT-TYPE    
  Counter32  

nvaAgSpNmvt 1.3.6.1.4.1.164.5.1.3.4.1.7
Number of NMVTs (of any type) sent to the SNA host.
OBJECT-TYPE    
  Counter32  

nvaAgSAlerts 1.3.6.1.4.1.164.5.1.3.4.1.9
Number of alert NMVTs sent by the NetView agent.
OBJECT-TYPE    
  Counter32  

nvaAgRRunCmd 1.3.6.1.4.1.164.5.1.3.4.1.10
Number of RUNCMD (execute-command NMVTs) received by the NetView agent.
OBJECT-TYPE    
  Counter32  

nvaAgSRunCmd 1.3.6.1.4.1.164.5.1.3.4.1.11
Number of RUNCMD replies sent to the NetView host.
OBJECT-TYPE    
  Counter32  

nvaAgSPdstat 1.3.6.1.4.1.164.5.1.3.4.1.12
Number of PDSTAT NMVTs sent by the NetView agent.
OBJECT-TYPE    
  Counter32  

snarSna 1.3.6.1.4.1.164.5.1.5
OBJECT IDENTIFIER    

snaSessTable 1.3.6.1.4.1.164.5.1.5.3
Holding SNA session's parameters for each side of a specific session, indexed by session_id
OBJECT-TYPE    
  SEQUENCE OF  
    SnaSessEntry

snaSessEntry 1.3.6.1.4.1.164.5.1.5.3.1
An entry in table snaSessTable.
OBJECT-TYPE    
  SnaSessEntry  

sessIfIndex 1.3.6.1.4.1.164.5.1.5.3.1.1
Interface used by this SNA session
OBJECT-TYPE    
  Integer32  

sessId 1.3.6.1.4.1.164.5.1.5.3.1.2
The unique identifier of the converted SNA session id
OBJECT-TYPE    
  Integer32  

sessSide 1.3.6.1.4.1.164.5.1.5.3.1.3
The SNA session side. Each session handled by SNAR/device, creates 2 SNA sessions, hereafter called 'side A' and 'side B' Configuration parameters, and Statistics are defined for each side separately.
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

sessDev 1.3.6.1.4.1.164.5.1.5.3.1.4
The device number, used in devices setup. N/A to SNAR.
OBJECT-TYPE    
  Integer32  

sessAdminStatus 1.3.6.1.4.1.164.5.1.5.3.1.5
Admin. status of this session, as requested by the manager. 10 - Session is invalid, and not handled by SNAR devices. 1 - Session is disabled. SNAR/Device will not try to start this session. 2- Session is enabled. SNAR/Device will try to start this session. 3- Under_creation - This session parameters are under creation, manipulated by a manager. 4 - stop: stop an enabled session immediately - no need to save change. 5 - start :start a stopped sessions immediately - no need to save change.
OBJECT-TYPE    
  INTEGER disable(1), enable(2), underCreation(3), stop(4), start(5), invalid(10)  

sessOperState 1.3.6.1.4.1.164.5.1.5.3.1.6
Current operating state. See Manual reference for more information.
OBJECT-TYPE    
  INTEGER stopped(1), disabled(2), sdlcProb03(3), llcProb04(4), ifProb30(30), ifProb80(80), ifProb81(81), ifProb87(87), ifProb88(88), ok(99)  

sessAccessType 1.3.6.1.4.1.164.5.1.5.3.1.7
The access type used by this side of the converted session.
OBJECT-TYPE    
  INTEGER llcCsmacd(1), llcTokenRing(3), sdlc(6), qllcX25(10)  

sessSXidBlockId 1.3.6.1.4.1.164.5.1.5.3.1.8
The BLOCKID part of the XID information sent by this side for the SNA session initiation
OBJECT-TYPE    
  OCTET STRING SIZE(2)  

sessSXidBlockNum 1.3.6.1.4.1.164.5.1.5.3.1.9
The BLOCKNUM part of the XID information sent by this side for the SNA session initiation
OBJECT-TYPE    
  OCTET STRING SIZE(3)  

sessSSap 1.3.6.1.4.1.164.5.1.5.3.1.10
The Local SAP used by SNAR for this session's side (LLC sessions only)
OBJECT-TYPE    
  Sap  

sessDSap 1.3.6.1.4.1.164.5.1.5.3.1.11
The remote SAP used by SNAR for this session's side (LLC sessions only)
OBJECT-TYPE    
  Sap  

sessRemMacAddr 1.3.6.1.4.1.164.5.1.5.3.1.12
The remote MAC address used by this session's side (LLC sessions only)
OBJECT-TYPE    
  MacAddress  

sessSdlcAddr 1.3.6.1.4.1.164.5.1.5.3.1.13
The SDLC address used by this session's side (SDLC sessions only, both primary and secondary)
OBJECT-TYPE    
  SdlcAddr  

sessGroupPoll 1.3.6.1.4.1.164.5.1.5.3.1.14
The address of the group poll in which this session's side participates (SLDC secondary only). A value of 0 indicates that it doesn't participate in any group. Only one group is supported for each SDLC line (same port)
OBJECT-TYPE    
  SdlcAddr  

sessRole 1.3.6.1.4.1.164.5.1.5.3.1.15
The type of SDLC session for this side.
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

sessIpEncapsulated 1.3.6.1.4.1.164.5.1.5.3.1.16
Specified whether this session data is encapsulated within UDP/IP
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

sessDestIpAddr 1.3.6.1.4.1.164.5.1.5.3.1.17
The destination IP address (IP encapsulated sessions only).
OBJECT-TYPE    
  IpAddress  

sessRemX25Addr 1.3.6.1.4.1.164.5.1.5.3.1.18
The remote X25 address (QLLC only) .
OBJECT-TYPE    
  OCTET STRING  

snaSessTuneTable 1.3.6.1.4.1.164.5.1.5.4
Holding SNA session parameters for each side of a specific session, indexed by session_id
OBJECT-TYPE    
  SEQUENCE OF  
    SnaSessTuneEntry

snaSessTuneEntry 1.3.6.1.4.1.164.5.1.5.4.1
An entry in table snaSessTuneTable.
OBJECT-TYPE    
  SnaSessTuneEntry  

sessTuneIfIndex 1.3.6.1.4.1.164.5.1.5.4.1.1
The SNA session side.
OBJECT-TYPE    
  Integer32  

sessTuneId 1.3.6.1.4.1.164.5.1.5.4.1.2
The unique identifier of the converted SNA session.
OBJECT-TYPE    
  Integer32  

sessTuneSide 1.3.6.1.4.1.164.5.1.5.4.1.3
The SNA session's side.
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

sessBufferSize 1.3.6.1.4.1.164.5.1.5.4.1.4
The max. buffer size of remote device (All sessions).
OBJECT-TYPE    
  Integer32  

sessSegmentation 1.3.6.1.4.1.164.5.1.5.4.1.5
Specifies whether the SNAR should perform segmentation when incoming frame on one side is longer then the sessSideBufferSize of the other size 1 - disable - don't perform segmentation 2 - enable - perform segmentation
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

sessFirstSide 1.3.6.1.4.1.164.5.1.5.4.1.6
Specifies which side of the two SNA sides (side_a or side_b) should be started first (SNAR only, N/A to devices)
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

sessWindow 1.3.6.1.4.1.164.5.1.5.4.1.7
The max window size (1 .. 127) for this session's side.
OBJECT-TYPE    
  Integer32  

sessDuplex 1.3.6.1.4.1.164.5.1.5.4.1.8
Specifies the type of SDLC device on the other end of the SDLC line. FULL- means a device capable of transmit and receive data simultaneously.
OBJECT-TYPE    
  INTEGER half(1), full(2)  

sessRXidBlockId 1.3.6.1.4.1.164.5.1.5.4.1.9
The BLOCKID part of the XID information expected to be received on this side of the SNA session
OBJECT-TYPE    
  OCTET STRING SIZE(2)  

sessRXidBlockNum 1.3.6.1.4.1.164.5.1.5.4.1.10
The BLOCKNUM part of the XID information expected to be received on this side of the SNA session
OBJECT-TYPE    
  OCTET STRING SIZE(3)  

sessCheckXid 1.3.6.1.4.1.164.5.1.5.4.1.11
Specified whether the received XID information should be checked and compared to the value of sessRXid: 1 - disable: don't check 2 - enable : check
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

sessT1 1.3.6.1.4.1.164.5.1.5.4.1.12
The T1 timer (in 100 msec) for this session's side.
OBJECT-TYPE    
  Integer32  

sessTi 1.3.6.1.4.1.164.5.1.5.4.1.13
The Ti timer (in sec) for this session
OBJECT-TYPE    
  Integer32  

sessT2 1.3.6.1.4.1.164.5.1.5.4.1.14
The T2 timer (in 100 msec) for this session
OBJECT-TYPE    
  Integer32  

sessN2 1.3.6.1.4.1.164.5.1.5.4.1.15
The N2 value for this session's side
OBJECT-TYPE    
  Integer32  

sessUdpPort 1.3.6.1.4.1.164.5.1.5.4.1.16
The UDP port used by SNAR (IP encapsulated sessions only)
OBJECT-TYPE    
  Integer32  

snaSessStatTable 1.3.6.1.4.1.164.5.1.5.5
Holding SNA session parameters for each side of a specific session, indexed by session_id
OBJECT-TYPE    
  SEQUENCE OF  
    SnaSessStatEntry

snaSessStatEntry 1.3.6.1.4.1.164.5.1.5.5.1
An entry in table snaSessStatTable.
OBJECT-TYPE    
  SnaSessStatEntry  

sessStatIfIndex 1.3.6.1.4.1.164.5.1.5.5.1.1
OBJECT-TYPE    
  Integer32  

sessStatId 1.3.6.1.4.1.164.5.1.5.5.1.2
The unique identifier of the converted SNA session.
OBJECT-TYPE    
  Integer32  

sessStatSide 1.3.6.1.4.1.164.5.1.5.5.1.3
The SNA session's side.
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

sessStatTime 1.3.6.1.4.1.164.5.1.5.5.1.4
Time since last reset of this session statistics. Setting to a value of 0 will clear all session statistics.
OBJECT-TYPE    
  TimeTicks  

sessSPius 1.3.6.1.4.1.164.5.1.5.5.1.5
The number of PIUs sent by this session's side
OBJECT-TYPE    
  Counter32  

sessSBytes 1.3.6.1.4.1.164.5.1.5.5.1.6
The number of bytes sent by this session's side.
OBJECT-TYPE    
  Counter32  

sessRPius 1.3.6.1.4.1.164.5.1.5.5.1.7
The number of PIUs received by this session
OBJECT-TYPE    
  Counter32  

sessRBytes 1.3.6.1.4.1.164.5.1.5.5.1.8
The number of bytes received by this session's side.
OBJECT-TYPE    
  Counter32  

sessSessFailure 1.3.6.1.4.1.164.5.1.5.5.1.9
The number of session failures occurs to this session's side.
OBJECT-TYPE    
  Counter32  

sessXidDenieds 1.3.6.1.4.1.164.5.1.5.5.1.10
The number of XID denied by this session's side
OBJECT-TYPE    
  Counter32  

snaSessQllcTable 1.3.6.1.4.1.164.5.1.5.7
Holding SNA session parameters for each side of a specific session, indexed by session_id
OBJECT-TYPE    
  SEQUENCE OF  
    SnaSessQllcEntry

snaSessQllcEntry 1.3.6.1.4.1.164.5.1.5.7.1
An entry in table snaSessQllcTable.
OBJECT-TYPE    
  SnaSessQllcEntry  

sessQllcIfIndex 1.3.6.1.4.1.164.5.1.5.7.1.1
OBJECT-TYPE    
  Integer32  

sessQllcId 1.3.6.1.4.1.164.5.1.5.7.1.2
The unique identifier of the converted SNA session.
OBJECT-TYPE    
  Integer32  

sessQllcSide 1.3.6.1.4.1.164.5.1.5.7.1.3
The SNA session's side.
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

sessInCalls 1.3.6.1.4.1.164.5.1.5.7.1.4
N/Allowed to accept call indicators (QLLC only) 1- disable: don't allow to accept call indications 2- enable: Allow to accept call indications
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

sessOutCalls 1.3.6.1.4.1.164.5.1.5.7.1.5
N/Allowed to initiate call requests (QLLC only) 1- disable: don't allow to initiate call requests 2- enable: Allow to initiate call requests
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

sessPVC 1.3.6.1.4.1.164.5.1.5.7.1.6
PVC being used or not (QLLC only) 1 - disable :not use 2 - enable :use
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

sessCallReqData 1.3.6.1.4.1.164.5.1.5.7.1.7
The user's data for call requests (QLLC only).
OBJECT-TYPE    
  OCTET STRING  

sessConnReqFacility 1.3.6.1.4.1.164.5.1.5.7.1.8
The facilities for connection requests (QLLC only).
OBJECT-TYPE    
  OCTET STRING  

sessGroupId 1.3.6.1.4.1.164.5.1.5.7.1.9
The facility group id (QLLC only)
OBJECT-TYPE    
  OCTET STRING  

sessDtePswd 1.3.6.1.4.1.164.5.1.5.7.1.10
The password for local DTE (QLLC only)
OBJECT-TYPE    
  OCTET STRING  

sessDteId 1.3.6.1.4.1.164.5.1.5.7.1.11
The identification for local DTE (QLLC only).
OBJECT-TYPE    
  OCTET STRING  

sessMaxInPktSize 1.3.6.1.4.1.164.5.1.5.7.1.12
The max inbound packet size (QLLC only).
OBJECT-TYPE    
  Integer32  

sessMaxOutPktSize 1.3.6.1.4.1.164.5.1.5.7.1.13
The max outbound packet size (QLLC only).
OBJECT-TYPE    
  Integer32  

sessCallIndReverse 1.3.6.1.4.1.164.5.1.5.7.1.14
OBJECT-TYPE    
  OCTET STRING  

cvtIfn 1.3.6.1.4.1.164.5.2
OBJECT IDENTIFIER    

cvtSdlc 1.3.6.1.4.1.164.5.2.1
OBJECT IDENTIFIER    

sdlcLinesNumber 1.3.6.1.4.1.164.5.2.1.1
OBJECT-TYPE    
  Integer32  

sdlcTable 1.3.6.1.4.1.164.5.2.1.3
OBJECT-TYPE    
  SEQUENCE OF  
    SdlcEntry

sdlcEntry 1.3.6.1.4.1.164.5.2.1.3.1
An entry in table sdlcTable.
OBJECT-TYPE    
  SdlcEntry  

sdlcIfIndex 1.3.6.1.4.1.164.5.2.1.3.1.1
The value of this object identifies the interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.
OBJECT-TYPE    
  Integer32  

sdlcNrz 1.3.6.1.4.1.164.5.2.1.3.1.2
OBJECT-TYPE    
  INTEGER nrz(1), nrzi(2)  

sdlcDuplex 1.3.6.1.4.1.164.5.2.1.3.1.3
OBJECT-TYPE    
  INTEGER half(1), full(2)  

sdlcClockType 1.3.6.1.4.1.164.5.2.1.3.1.4
OBJECT-TYPE    
  INTEGER external(1), internal(2)  

sdlcSpeed 1.3.6.1.4.1.164.5.2.1.3.1.5
OBJECT-TYPE    
  Integer32  

sdlcConnectorType 1.3.6.1.4.1.164.5.2.1.3.1.6
OBJECT-TYPE    
  DisplayString  

sdlcRts 1.3.6.1.4.1.164.5.2.1.3.1.7
OBJECT-TYPE    
  INTEGER constatnt(1), controled(2)  

sdlcStatTable 1.3.6.1.4.1.164.5.2.1.4
OBJECT-TYPE    
  SEQUENCE OF  
    SdlcStatEntry

sdlcStatEntry 1.3.6.1.4.1.164.5.2.1.4.1
An entry in table sdlcStatTable.
OBJECT-TYPE    
  SdlcStatEntry  

sdlcStatIfIndex 1.3.6.1.4.1.164.5.2.1.4.1.1
The value of this object identifies the interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.
OBJECT-TYPE    
  Integer32  

sdlcTimeSinceReset 1.3.6.1.4.1.164.5.2.1.4.1.2
The time laps since the last reset statistics. Setting the object to 0 will reset all line statistics.
OBJECT-TYPE    
  TimeTicks  

sdlcStatFramesTrans 1.3.6.1.4.1.164.5.2.1.4.1.3
OBJECT-TYPE    
  Counter32  

sdlcStatBytesTrans 1.3.6.1.4.1.164.5.2.1.4.1.4
OBJECT-TYPE    
  Counter32  

sdlcStatFramesRcv 1.3.6.1.4.1.164.5.2.1.4.1.5
OBJECT-TYPE    
  Counter32  

sdlcStatBytesRcv 1.3.6.1.4.1.164.5.2.1.4.1.6
OBJECT-TYPE    
  Counter32  

sdlcStatFramesAbort 1.3.6.1.4.1.164.5.2.1.4.1.7
OBJECT-TYPE    
  Counter32  

sdlcStatFramesBad 1.3.6.1.4.1.164.5.2.1.4.1.8
This counter holds the number of all bad frames.
OBJECT-TYPE    
  Counter32  

sdlcStatFramesCrc 1.3.6.1.4.1.164.5.2.1.4.1.9
OBJECT-TYPE    
  Counter32  

cvtDot5 1.3.6.1.4.1.164.5.2.2
OBJECT IDENTIFIER    

cvtDot5Table 1.3.6.1.4.1.164.5.2.2.1
This table contains Token Ring interface parameters and state variables. One entry per 802.3 interface.
OBJECT-TYPE    
  SEQUENCE OF  
    CvtDot5Entry

cvtDot5Entry 1.3.6.1.4.1.164.5.2.2.1.1
An entry in table cvtDot5Table.
OBJECT-TYPE    
  CvtDot5Entry  

cvtDot5IfIndex 1.3.6.1.4.1.164.5.2.2.1.1.1
The value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.
OBJECT-TYPE    
  Integer32  

cvtDot5MacAddr 1.3.6.1.4.1.164.5.2.2.1.1.2
OBJECT-TYPE    
  MacAddress  

cvtDot5Commands 1.3.6.1.4.1.164.5.2.2.1.1.3
When this object is set to the value of open(2), the station should go into the open state. When this object is set to the value of of reset(3), the station should perform reset. When this object is set to the value of close(4), the station should go into the stopped state by removing itself from the ring. Setting this object to a value of no-op(1) has no effect. When read, this object always has a value of no-op(1).
OBJECT-TYPE    
  INTEGER no-op(1), open(2), reset(3), close(4)  

cvtDot5RingSpeed 1.3.6.1.4.1.164.5.2.2.1.1.4
The ring's bandwidth.
OBJECT-TYPE    
  INTEGER unknown(1), oneMegabit(2), fourMegabit(3), sixteenMegabit(4)  

cvtDot5ActMonParticipate 1.3.6.1.4.1.164.5.2.2.1.1.5
If this object has a value of true(1) then this interface will participate in the active monitor selection process. If the value is false(2) then it will not. Setting this object might not have an effect until the next time the interface is opened.
OBJECT-TYPE    
  INTEGER true(1), false(2)  

cvtDot5Functional 1.3.6.1.4.1.164.5.2.2.1.1.6
The bit mask of all TR functional addresses for which this interface will accept frames.
OBJECT-TYPE    
  MacAddress  

cvtDot3 1.3.6.1.4.1.164.5.2.3
OBJECT IDENTIFIER    

cvtDot3Table 1.3.6.1.4.1.164.5.2.3.1
This table contains ETHERNET interface parameters and state variables, one entry per 802.3 interface.
OBJECT-TYPE    
  SEQUENCE OF  
    CvtDot3Entry

cvtDot3Entry 1.3.6.1.4.1.164.5.2.3.1.1
An entry in table cvtDot3Table.
OBJECT-TYPE    
  CvtDot3Entry  

cvtDot3IfIndex 1.3.6.1.4.1.164.5.2.3.1.1.1
The value of this object identifies the 802.3 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.
OBJECT-TYPE    
  Integer32  

cvtDot3MacAddr 1.3.6.1.4.1.164.5.2.3.1.1.2
OBJECT-TYPE    
  MacAddress  

cvtDot3Commands 1.3.6.1.4.1.164.5.2.3.1.1.3
When this object is set to the value of open(2), the station should go into the open state. of reset(3), then the station should do a reset. On a reset, all MIB counters should retain their values, if possible. Other side affects are dependent on the hardware chip set. When this object is set to the value of close(4), the station should go into the stopped state by removing itself from the ring. Setting this object to a value of no-op(1) has no effect. When read, this object always has a value of no-op(1).
OBJECT-TYPE    
  INTEGER no-op(1), open(2), reset(3), close(4)  

cvtDot3ActMonParticipate 1.3.6.1.4.1.164.5.2.3.1.1.4
If this object has a value of true(1) then this interface will participate in the active monitor selection process. If the value is false(2) then it will not. Setting this object might not have an effect until the next time the interface is opened.
OBJECT-TYPE    
  INTEGER true(1), false(2)  

cvtDot3Functional 1.3.6.1.4.1.164.5.2.3.1.1.5
The bit mask of all Ethernet functional addresses for which this interface will accept frames.
OBJECT-TYPE    
  MacAddress  

radGen 1.3.6.1.4.1.164.6
OBJECT IDENTIFIER    

systems 1.3.6.1.4.1.164.6.1
OBJECT IDENTIFIER    

systemsEvents 1.3.6.1.4.1.164.6.1.0
The events for RAD products.
OBJECT-IDENTITY    

tftpStatusChangeTrap 1.3.6.1.4.1.164.6.1.0.1
This trap is sent whenever the status of tftp changed.
NOTIFICATION-TYPE    
  tftpStatus  

agnStatusChangeTrap 1.3.6.1.4.1.164.6.1.0.2
This trap is sent whenever the state of the entity the agent is responsible for changed. TDM devices will send agnTestStatus variable to indicate the current test status.
NOTIFICATION-TYPE    
  agnIndication  

prtStatusChangeTrap 1.3.6.1.4.1.164.6.1.0.3
This trap is sent whenever the state of a port changed. Attached, will be parameter/s that indicate the new port status. The attached variables will be specified in the specifications of the products supporting this trap.
NOTIFICATION-TYPE    

swdlStatusResult 1.3.6.1.4.1.164.6.1.0.4
This notification is sent when Software Down Load is finished. The attached object indicates the File Name.
NOTIFICATION-TYPE    
  swdlStatusFileName  

intSwdlSlotFileMismatch 1.3.6.1.4.1.164.6.1.0.5
This notification is sent when the card in the chosen slot doesn't match the chosen file. The attached object indicates the File Name.
NOTIFICATION-TYPE    
  intSwdlFileName  

agnCounterChange 1.3.6.1.4.1.164.6.1.0.6
This notification is sent when the value of a specific Counter is changed. Agent can send as attached object the updated Counter. For details about this Counter and attached object, see spec of the relevant application.
NOTIFICATION-TYPE    

prtClkSrcChangeTrap 1.3.6.1.4.1.164.6.1.0.7
This trap is sent upon any port clock change.
NOTIFICATION-TYPE    

moduleFailTrap 1.3.6.1.4.1.164.6.1.0.8
This trap is sent upon a module failure.
NOTIFICATION-TYPE    

moduleInitFailTrap 1.3.6.1.4.1.164.6.1.0.9
This trap is sent upon a module initialization failure.
NOTIFICATION-TYPE    

clkSrcChangeTrap 1.3.6.1.4.1.164.6.1.0.10
This trap is sent upon any change in Clock Source.
NOTIFICATION-TYPE    

agnUploadDataTrap 1.3.6.1.4.1.164.6.1.0.11
This trap is sent upon an upload data session termination. For more details see product specification.
NOTIFICATION-TYPE    

enrollmentTrap 1.3.6.1.4.1.164.6.1.0.12
This trap is a periodic trap, which is sent to manager until Agent gets any response (Get or Set) from this manager.
NOTIFICATION-TYPE    

agnPowerFailureTrap 1.3.6.1.4.1.164.6.1.0.13
This trap is sent upon power failure. It is applicable for devices having one PS unit, which sense in advance the failure, and still have time to send this trap before it goes off.
NOTIFICATION-TYPE    

radSysTR 1.3.6.1.4.1.164.6.1.1
OBJECT IDENTIFIER    

radRADring 1.3.6.1.4.1.164.6.1.1.1
OBJECT IDENTIFIER    

radTMA 1.3.6.1.4.1.164.6.1.1.2
OBJECT IDENTIFIER    

radRingMonitor 1.3.6.1.4.1.164.6.1.1.3
OBJECT IDENTIFIER    

radSysFddi 1.3.6.1.4.1.164.6.1.2
OBJECT IDENTIFIER    

radFDX100 1.3.6.1.4.1.164.6.1.2.1
OBJECT IDENTIFIER    

radSysWan 1.3.6.1.4.1.164.6.1.3
OBJECT IDENTIFIER    

radSysWanEvents 1.3.6.1.4.1.164.6.1.3.0
The events for RAD Wan products.
OBJECT-IDENTITY    

imxAlarmTrap 1.3.6.1.4.1.164.6.1.3.0.2
The trap is sent every time a new alarm is logged into the alarm buffer. The trap may not be sent more than once in a five second interval.
NOTIFICATION-TYPE    

imxCallLogTrap 1.3.6.1.4.1.164.6.1.3.0.3
The trap is sent every time a new call log entry is logged into the log buffer. The trap may not be sent more than once in a five second interval.
NOTIFICATION-TYPE    

imxPingTrap 1.3.6.1.4.1.164.6.1.3.0.4
The trap is sent every time a ping operation is performed on a channel.
NOTIFICATION-TYPE    
  chStatOperStatus  

radMP2100 1.3.6.1.4.1.164.6.1.3.1
OBJECT IDENTIFIER    

radMP2104 1.3.6.1.4.1.164.6.1.3.2
OBJECT IDENTIFIER    

radMP2100B 1.3.6.1.4.1.164.6.1.3.3
OBJECT IDENTIFIER    

radMP2100F 1.3.6.1.4.1.164.6.1.3.4
OBJECT IDENTIFIER    

radMP2100H 1.3.6.1.4.1.164.6.1.3.5
OBJECT IDENTIFIER    

radMP2104H 1.3.6.1.4.1.164.6.1.3.6
OBJECT IDENTIFIER    

radMP2200B 1.3.6.1.4.1.164.6.1.3.7
OBJECT IDENTIFIER    

radMP2200F 1.3.6.1.4.1.164.6.1.3.8
OBJECT IDENTIFIER    

radMX3000 1.3.6.1.4.1.164.6.1.3.9
OBJECT IDENTIFIER    

radMX3004 1.3.6.1.4.1.164.6.1.3.10
OBJECT IDENTIFIER    

radMX30 1.3.6.1.4.1.164.6.1.3.11
OBJECT IDENTIFIER    

radMX300 1.3.6.1.4.1.164.6.1.3.12
OBJECT IDENTIFIER    

radVOIP 1.3.6.1.4.1.164.6.1.3.13
OBJECT IDENTIFIER    

radKM2100 1.3.6.1.4.1.164.6.1.3.15
OBJECT IDENTIFIER    

radKM2104 1.3.6.1.4.1.164.6.1.3.16
OBJECT IDENTIFIER    

radDXC30 1.3.6.1.4.1.164.6.1.3.20
OBJECT IDENTIFIER    

radDXC10A 1.3.6.1.4.1.164.6.1.3.21
OBJECT IDENTIFIER    

radDXC8R 1.3.6.1.4.1.164.6.1.3.22
OBJECT IDENTIFIER    

radDXC30E 1.3.6.1.4.1.164.6.1.3.23
OBJECT IDENTIFIER    

radDXC3000 1.3.6.1.4.1.164.6.1.3.24
OBJECT IDENTIFIER    

radDXC8RNew 1.3.6.1.4.1.164.6.1.3.25
OBJECT IDENTIFIER    

radFcdE1L 1.3.6.1.4.1.164.6.1.3.29
OBJECT IDENTIFIER    

radFcdT1 1.3.6.1.4.1.164.6.1.3.30
OBJECT IDENTIFIER    

radFcdE1 1.3.6.1.4.1.164.6.1.3.31
OBJECT IDENTIFIER    

radFcdE1I 1.3.6.1.4.1.164.6.1.3.32
OBJECT IDENTIFIER    

radFcdT1M 1.3.6.1.4.1.164.6.1.3.33
OBJECT IDENTIFIER    

radFcdE1M 1.3.6.1.4.1.164.6.1.3.34
OBJECT IDENTIFIER    

radFcdIP 1.3.6.1.4.1.164.6.1.3.35
OBJECT IDENTIFIER    

radFcdT1A 1.3.6.1.4.1.164.6.1.3.36
OBJECT IDENTIFIER    

radFcdE1A 1.3.6.1.4.1.164.6.1.3.37
OBJECT IDENTIFIER    

radFcdW 1.3.6.1.4.1.164.6.1.3.38
OBJECT IDENTIFIER    

radFcdSTM 1.3.6.1.4.1.164.6.1.3.39
OBJECT IDENTIFIER    

radHtuE1Sa 1.3.6.1.4.1.164.6.1.3.40
OBJECT IDENTIFIER    

radHtuE1 1.3.6.1.4.1.164.6.1.3.41
OBJECT IDENTIFIER    

radHtu2Sa 1.3.6.1.4.1.164.6.1.3.42
OBJECT IDENTIFIER    

radHtu2 1.3.6.1.4.1.164.6.1.3.43
OBJECT IDENTIFIER    

radAsmi450R768Sa 1.3.6.1.4.1.164.6.1.3.44
OBJECT IDENTIFIER    

radAsmi450R768 1.3.6.1.4.1.164.6.1.3.45
OBJECT IDENTIFIER    

radAsmi450R1152Sa 1.3.6.1.4.1.164.6.1.3.46
OBJECT IDENTIFIER    

radAsmi450R1152 1.3.6.1.4.1.164.6.1.3.47
OBJECT IDENTIFIER    

radLrs12F 1.3.6.1.4.1.164.6.1.3.48
OBJECT IDENTIFIER    

radLrs12B 1.3.6.1.4.1.164.6.1.3.49
OBJECT IDENTIFIER    

radLrs52 1.3.6.1.4.1.164.6.1.3.50
OBJECT IDENTIFIER    

radHcdE1Sa 1.3.6.1.4.1.164.6.1.3.51
OBJECT IDENTIFIER    

radHcdE1 1.3.6.1.4.1.164.6.1.3.52
OBJECT IDENTIFIER    

radHtuT1Sa 1.3.6.1.4.1.164.6.1.3.53
OBJECT IDENTIFIER    

radHtuT1 1.3.6.1.4.1.164.6.1.3.54
OBJECT IDENTIFIER    

radOptimux4E1 1.3.6.1.4.1.164.6.1.3.55
OBJECT IDENTIFIER    

radOptimux4T1 1.3.6.1.4.1.164.6.1.3.56
OBJECT IDENTIFIER    

radOptimuxXLE1 1.3.6.1.4.1.164.6.1.3.57
OBJECT IDENTIFIER    

radOptimuxXLT1 1.3.6.1.4.1.164.6.1.3.58
OBJECT IDENTIFIER    

radOptimuxXL16E1 1.3.6.1.4.1.164.6.1.3.59
OBJECT IDENTIFIER    

radImx64 1.3.6.1.4.1.164.6.1.3.60
OBJECT IDENTIFIER    

radImx6L 1.3.6.1.4.1.164.6.1.3.61
OBJECT IDENTIFIER    

radImx2 1.3.6.1.4.1.164.6.1.3.62
OBJECT IDENTIFIER    

radImx4T1 1.3.6.1.4.1.164.6.1.3.63
OBJECT IDENTIFIER    

radImx4E1 1.3.6.1.4.1.164.6.1.3.64
OBJECT IDENTIFIER    

radImx2T1E1 1.3.6.1.4.1.164.6.1.3.65
OBJECT IDENTIFIER    

radImxi4 1.3.6.1.4.1.164.6.1.3.66
OBJECT IDENTIFIER    

radOptimux4T1L 1.3.6.1.4.1.164.6.1.3.68
OBJECT IDENTIFIER    

radOptimux4E1L 1.3.6.1.4.1.164.6.1.3.69
OBJECT IDENTIFIER    

radHtuE1SaV2 1.3.6.1.4.1.164.6.1.3.70
OBJECT IDENTIFIER    

radHtuE1V2 1.3.6.1.4.1.164.6.1.3.71
OBJECT IDENTIFIER    

radFomiE3 1.3.6.1.4.1.164.6.1.3.72
OBJECT IDENTIFIER    

radFomiT3 1.3.6.1.4.1.164.6.1.3.73
OBJECT IDENTIFIER    

radOpt4E1C 1.3.6.1.4.1.164.6.1.3.74
OBJECT IDENTIFIER    

radOpt4T1C 1.3.6.1.4.1.164.6.1.3.75
OBJECT IDENTIFIER    

radPrbiE3 1.3.6.1.4.1.164.6.1.3.76
OBJECT IDENTIFIER    

radPrbiT3 1.3.6.1.4.1.164.6.1.3.77
OBJECT IDENTIFIER    

radHcd4Sa 1.3.6.1.4.1.164.6.1.3.78
OBJECT IDENTIFIER    

radOptimuxT3 1.3.6.1.4.1.164.6.1.3.79
OBJECT IDENTIFIER    

radFRmon 1.3.6.1.4.1.164.6.1.3.80
OBJECT IDENTIFIER    

radIpMux4 1.3.6.1.4.1.164.6.1.3.81
OBJECT IDENTIFIER    

radIpMux1 1.3.6.1.4.1.164.6.1.3.82
OBJECT IDENTIFIER    

radIpMux16 1.3.6.1.4.1.164.6.1.3.83
OBJECT IDENTIFIER    

radIpMux1E 1.3.6.1.4.1.164.6.1.3.84
OBJECT IDENTIFIER    

radVmux2100 1.3.6.1.4.1.164.6.1.3.85
OBJECT IDENTIFIER    

radVmux110 1.3.6.1.4.1.164.6.1.3.88
OBJECT IDENTIFIER    

radIpMux8 1.3.6.1.4.1.164.6.1.3.91
OBJECT IDENTIFIER    

radSysBRG 1.3.6.1.4.1.164.6.1.4
OBJECT IDENTIFIER    

radTRE1 1.3.6.1.4.1.164.6.1.4.1
OBJECT IDENTIFIER    

radTRE1D 1.3.6.1.4.1.164.6.1.4.2
OBJECT IDENTIFIER    

radTRE8 1.3.6.1.4.1.164.6.1.4.3
OBJECT IDENTIFIER    

radTRE8D 1.3.6.1.4.1.164.6.1.4.4
OBJECT IDENTIFIER    

radMBE1 1.3.6.1.4.1.164.6.1.4.5
OBJECT IDENTIFIER    

radMBE1D 1.3.6.1.4.1.164.6.1.4.6
OBJECT IDENTIFIER    

radMBE8 1.3.6.1.4.1.164.6.1.4.7
OBJECT IDENTIFIER    

radMBE8D 1.3.6.1.4.1.164.6.1.4.8
OBJECT IDENTIFIER    

radMLBT 1.3.6.1.4.1.164.6.1.4.9
OBJECT IDENTIFIER    

radFEB4DAS 1.3.6.1.4.1.164.6.1.4.10
OBJECT IDENTIFIER    

radTrimBrg10 1.3.6.1.4.1.164.6.1.4.11
OBJECT IDENTIFIER    

radTrimBrg16 1.3.6.1.4.1.164.6.1.4.12
OBJECT IDENTIFIER    

radRRTRE8 1.3.6.1.4.1.164.6.1.4.13
OBJECT IDENTIFIER    

radRRTRE8D 1.3.6.1.4.1.164.6.1.4.14
OBJECT IDENTIFIER    

radRRMLBT 1.3.6.1.4.1.164.6.1.4.15
OBJECT IDENTIFIER    

radRRMLBTF 1.3.6.1.4.1.164.6.1.4.16
OBJECT IDENTIFIER    

radRRTRE1D 1.3.6.1.4.1.164.6.1.4.17
OBJECT IDENTIFIER    

radTRERAS 1.3.6.1.4.1.164.6.1.4.18
OBJECT IDENTIFIER    

radTRERASa 1.3.6.1.4.1.164.6.1.4.19
OBJECT IDENTIFIER    

radMBERAS 1.3.6.1.4.1.164.6.1.4.20
OBJECT IDENTIFIER    

radMBERASa 1.3.6.1.4.1.164.6.1.4.21
OBJECT IDENTIFIER    

radFEB4FDX 1.3.6.1.4.1.164.6.1.4.22
OBJECT IDENTIFIER    

radFEB4SAS 1.3.6.1.4.1.164.6.1.4.23
OBJECT IDENTIFIER    

radRRFTBDAS 1.3.6.1.4.1.164.6.1.4.24
OBJECT IDENTIFIER    

radRRFTBSAS 1.3.6.1.4.1.164.6.1.4.25
OBJECT IDENTIFIER    

radFTBDAS 1.3.6.1.4.1.164.6.1.4.26
OBJECT IDENTIFIER    

radFTBSAS 1.3.6.1.4.1.164.6.1.4.27
OBJECT IDENTIFIER    

radFastWay100 1.3.6.1.4.1.164.6.1.4.28
OBJECT IDENTIFIER    

radSysCnvrtr 1.3.6.1.4.1.164.6.1.5
OBJECT IDENTIFIER    

radSTC1 1.3.6.1.4.1.164.6.1.5.1
OBJECT IDENTIFIER    

radSTC2 1.3.6.1.4.1.164.6.1.5.3
OBJECT IDENTIFIER    

radSTC1UDP 1.3.6.1.4.1.164.6.1.5.4
OBJECT IDENTIFIER    

radSTC2UDP 1.3.6.1.4.1.164.6.1.5.6
OBJECT IDENTIFIER    

radFTC1 1.3.6.1.4.1.164.6.1.5.10
OBJECT IDENTIFIER    

radFTC2 1.3.6.1.4.1.164.6.1.5.12
OBJECT IDENTIFIER    

radFTC1UDP 1.3.6.1.4.1.164.6.1.5.13
OBJECT IDENTIFIER    

radFTC2UDP 1.3.6.1.4.1.164.6.1.5.15
OBJECT IDENTIFIER    

radSEC1 1.3.6.1.4.1.164.6.1.5.20
OBJECT IDENTIFIER    

radSEC2 1.3.6.1.4.1.164.6.1.5.22
OBJECT IDENTIFIER    

radSEC1UDP 1.3.6.1.4.1.164.6.1.5.23
OBJECT IDENTIFIER    

radSEC2UDP 1.3.6.1.4.1.164.6.1.5.25
OBJECT IDENTIFIER    

radFEC1 1.3.6.1.4.1.164.6.1.5.30
OBJECT IDENTIFIER    

radFEC2 1.3.6.1.4.1.164.6.1.5.32
OBJECT IDENTIFIER    

radFEC1UDP 1.3.6.1.4.1.164.6.1.5.33
OBJECT IDENTIFIER    

radFEC2UDP 1.3.6.1.4.1.164.6.1.5.35
OBJECT IDENTIFIER    

radSysStkHub 1.3.6.1.4.1.164.6.1.7
OBJECT IDENTIFIER    

radRBHE 1.3.6.1.4.1.164.6.1.7.1
OBJECT IDENTIFIER    

radRBHEEvents 1.3.6.1.4.1.164.6.1.7.1.0
The events for RAD Stackable products.
OBJECT-IDENTITY    

resetRequired 1.3.6.1.4.1.164.6.1.7.1.0.10
This trap indicates that in order to perform the last SET request, a reset operation of the router/bridge is required. This occurs when the layer 2 routing algorithm is changed between SPF and Spanning Tree. The reset can be performed manually or using the variable radBridgeAction.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

compNotActive 1.3.6.1.4.1.164.6.1.7.1.0.20
Compression was enabled but cannot be activated, since connected device does not support correct compression.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

noCompression 1.3.6.1.4.1.164.6.1.7.1.0.21
Compression card not present.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

errorBackUp 1.3.6.1.4.1.164.6.1.7.1.0.22
Automatic switchover to backup link because of excessive link errors.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

faultBackUp 1.3.6.1.4.1.164.6.1.7.1.0.23
Automatic switchover to backup link because of main link fault.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

mainLinkUp 1.3.6.1.4.1.164.6.1.7.1.0.24
Communication returned to main link.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

failedDialUp 1.3.6.1.4.1.164.6.1.7.1.0.25
Cannot establish backup dial-up connection.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

extLoopBack 1.3.6.1.4.1.164.6.1.7.1.0.29
This trap is sent when Loopback starts on the link.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

dialUpConnFailed 1.3.6.1.4.1.164.6.1.7.1.0.41
This trap is sent when the dialUp connection is terminated due to a failure.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

dialUpConnEstablished 1.3.6.1.4.1.164.6.1.7.1.0.42
This trap is sent when the dialUp connection is established.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

radRBHT 1.3.6.1.4.1.164.6.1.7.2
OBJECT IDENTIFIER    

radRBHTEvents 1.3.6.1.4.1.164.6.1.7.2.0
The events for RAD Stackable products.
OBJECT-IDENTITY    

ringBeaconing 1.3.6.1.4.1.164.6.1.7.2.0.30
This trap is sent when Token Ring LAN is beaconing.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

lanAdapterRemoved 1.3.6.1.4.1.164.6.1.7.2.0.31
This trap is sent when Token Ring LAN adapter was removed by LAN manager.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

dialUpConnTerminated 1.3.6.1.4.1.164.6.1.7.2.0.43
This trap is sent when the dialUp connection is normally terminated.
NOTIFICATION-TYPE    
  trimErrorDesc  
  trimErrorSeverity  
  agnLed  

radETS4fddiDAS 1.3.6.1.4.1.164.6.1.7.3
OBJECT IDENTIFIER    

radETS4fddiSAS 1.3.6.1.4.1.164.6.1.7.4
OBJECT IDENTIFIER    

radSAHEMX 1.3.6.1.4.1.164.6.1.7.5
OBJECT IDENTIFIER    

radSAHTM 1.3.6.1.4.1.164.6.1.7.6
OBJECT IDENTIFIER    

radETS4 1.3.6.1.4.1.164.6.1.7.7
OBJECT IDENTIFIER    

radSAHEMU 1.3.6.1.4.1.164.6.1.7.8
OBJECT IDENTIFIER    

unknown 1.3.6.1.4.1.164.6.1.7.9
OBJECT IDENTIFIER    

radSAH16Eint 1.3.6.1.4.1.164.6.1.7.10
OBJECT IDENTIFIER    

radSAH16Tint 1.3.6.1.4.1.164.6.1.7.11
OBJECT IDENTIFIER    

radSAH16Eext 1.3.6.1.4.1.164.6.1.7.12
OBJECT IDENTIFIER    

radSAH16Text 1.3.6.1.4.1.164.6.1.7.13
OBJECT IDENTIFIER    

radSysPS 1.3.6.1.4.1.164.6.1.8
OBJECT IDENTIFIER    

radSysPSEvents 1.3.6.1.4.1.164.6.1.8.0
The events for RAD Packet Switch (PS) products.
OBJECT-IDENTITY    

linkProtocolChanged 1.3.6.1.4.1.164.6.1.8.0.1
Upon setting of a new protocol to a specific interface.
NOTIFICATION-TYPE    
  pktSwchPhyInterfaceIfIndex  
  pktSwchPhyInterfaceProtocolA  

enrollmentPS 1.3.6.1.4.1.164.6.1.8.0.2
Periodic trap to be sent to the list of managers.
NOTIFICATION-TYPE    

rtsChange 1.3.6.1.4.1.164.6.1.8.0.3
NOTIFICATION-TYPE    
  pktSwchChannelNumberA  

ledStatusChange 1.3.6.1.4.1.164.6.1.8.0.4
The trap is sent when one of the Hazard LEDs has changed.
NOTIFICATION-TYPE    
  agnLed  

radSPS2 1.3.6.1.4.1.164.6.1.8.1
OBJECT IDENTIFIER    

radSPS3 1.3.6.1.4.1.164.6.1.8.2
OBJECT IDENTIFIER    

radSPS6 1.3.6.1.4.1.164.6.1.8.3
OBJECT IDENTIFIER    

radSPS9 1.3.6.1.4.1.164.6.1.8.4
OBJECT IDENTIFIER    

radSPS12 1.3.6.1.4.1.164.6.1.8.5
OBJECT IDENTIFIER    

radAPD2 1.3.6.1.4.1.164.6.1.8.6
OBJECT IDENTIFIER    

radAPD8 1.3.6.1.4.1.164.6.1.8.7
OBJECT IDENTIFIER    

radAPS8 1.3.6.1.4.1.164.6.1.8.8
OBJECT IDENTIFIER    

radAPS16 1.3.6.1.4.1.164.6.1.8.9
OBJECT IDENTIFIER    

radAPS24 1.3.6.1.4.1.164.6.1.8.10
OBJECT IDENTIFIER    

radSPS3S 1.3.6.1.4.1.164.6.1.8.11
OBJECT IDENTIFIER    

radFPS8 1.3.6.1.4.1.164.6.1.8.12
OBJECT IDENTIFIER    

radFPS12 1.3.6.1.4.1.164.6.1.8.13
OBJECT IDENTIFIER    

radSPS3ScSL 1.3.6.1.4.1.164.6.1.8.14
OBJECT IDENTIFIER    

radSPS3Sc2S 1.3.6.1.4.1.164.6.1.8.15
OBJECT IDENTIFIER    

radFPS8c 1.3.6.1.4.1.164.6.1.8.16
OBJECT IDENTIFIER    

radFPS4 1.3.6.1.4.1.164.6.1.8.17
OBJECT IDENTIFIER    

radSysEth 1.3.6.1.4.1.164.6.1.9
OBJECT IDENTIFIER    

radEP8T 1.3.6.1.4.1.164.6.1.9.1
OBJECT IDENTIFIER    

radEP4TAUI 1.3.6.1.4.1.164.6.1.9.2
OBJECT IDENTIFIER    

radEP4T2FL 1.3.6.1.4.1.164.6.1.9.3
OBJECT IDENTIFIER    

radEP4TFL 1.3.6.1.4.1.164.6.1.9.4
OBJECT IDENTIFIER    

radEP4FL 1.3.6.1.4.1.164.6.1.9.5
OBJECT IDENTIFIER    

radEPR8T 1.3.6.1.4.1.164.6.1.9.7
OBJECT IDENTIFIER    

radEPR4TAUI 1.3.6.1.4.1.164.6.1.9.8
OBJECT IDENTIFIER    

radEPR4T2FL 1.3.6.1.4.1.164.6.1.9.9
OBJECT IDENTIFIER    

radEPR4TFL 1.3.6.1.4.1.164.6.1.9.10
OBJECT IDENTIFIER    

radEPR4FL 1.3.6.1.4.1.164.6.1.9.11
OBJECT IDENTIFIER    

radSysRtr 1.3.6.1.4.1.164.6.1.11
OBJECT IDENTIFIER    

radSysRtrEvents 1.3.6.1.4.1.164.6.1.11.0
The events for RAD Router products.
OBJECT-IDENTITY    

radRTED 1.3.6.1.4.1.164.6.1.11.1
OBJECT IDENTIFIER    

radRTEM 1.3.6.1.4.1.164.6.1.11.2
OBJECT IDENTIFIER    

radRTEC 1.3.6.1.4.1.164.6.1.11.3
OBJECT IDENTIFIER    

radWebRanger 1.3.6.1.4.1.164.6.1.11.4
OBJECT IDENTIFIER    

radTinyRouter 1.3.6.1.4.1.164.6.1.11.5
OBJECT IDENTIFIER    

radLA240 1.3.6.1.4.1.164.6.1.11.6
OBJECT IDENTIFIER    

radSuperLan 1.3.6.1.4.1.164.6.1.11.7
OBJECT IDENTIFIER    

radLA240I 1.3.6.1.4.1.164.6.1.11.8
OBJECT IDENTIFIER    

radFcdIsdn 1.3.6.1.4.1.164.6.1.11.9
OBJECT IDENTIFIER    

radEFcdIp 1.3.6.1.4.1.164.6.1.11.10
OBJECT IDENTIFIER    

radFcdIpD 1.3.6.1.4.1.164.6.1.11.11
OBJECT IDENTIFIER    

radFcdIpM 1.3.6.1.4.1.164.6.1.11.12
OBJECT IDENTIFIER    

radSysAtm 1.3.6.1.4.1.164.6.1.12
OBJECT IDENTIFIER    

radSysAtmEvents 1.3.6.1.4.1.164.6.1.12.0
The events for RAD ATM products.
OBJECT-IDENTITY    

radStarSwitch 1.3.6.1.4.1.164.6.1.12.1
OBJECT IDENTIFIER    

radStarSwitchATM25 1.3.6.1.4.1.164.6.1.12.1.1
OBJECT IDENTIFIER    

radStarSwitchATM25L 1.3.6.1.4.1.164.6.1.12.1.2
OBJECT IDENTIFIER    

radStarSwitchATM155 1.3.6.1.4.1.164.6.1.12.1.3
OBJECT IDENTIFIER    

radAtmCsuDsu 1.3.6.1.4.1.164.6.1.12.2
OBJECT IDENTIFIER    

radAmcdE1 1.3.6.1.4.1.164.6.1.12.2.1
OBJECT IDENTIFIER    

radAmcdT1 1.3.6.1.4.1.164.6.1.12.2.2
OBJECT IDENTIFIER    

radAce20E 1.3.6.1.4.1.164.6.1.12.2.3
OBJECT IDENTIFIER    

radAce20T 1.3.6.1.4.1.164.6.1.12.2.4
OBJECT IDENTIFIER    

radAce2005 1.3.6.1.4.1.164.6.1.12.2.5
OBJECT IDENTIFIER    

radAce2002 1.3.6.1.4.1.164.6.1.12.2.6
OBJECT IDENTIFIER    

radAce2002E 1.3.6.1.4.1.164.6.1.12.2.7
OBJECT IDENTIFIER    

radAce2E 1.3.6.1.4.1.164.6.1.12.2.8
OBJECT IDENTIFIER    

radAce2T 1.3.6.1.4.1.164.6.1.12.2.9
OBJECT IDENTIFIER    

radMlAtmE1 1.3.6.1.4.1.164.6.1.12.2.10
OBJECT IDENTIFIER    

radMlAtmT1 1.3.6.1.4.1.164.6.1.12.2.11
OBJECT IDENTIFIER    

radAmc102 1.3.6.1.4.1.164.6.1.12.2.12
OBJECT IDENTIFIER    

radAmc102c 1.3.6.1.4.1.164.6.1.12.2.13
OBJECT IDENTIFIER    

radAce202 1.3.6.1.4.1.164.6.1.12.2.14
OBJECT IDENTIFIER    

radAce 1.3.6.1.4.1.164.6.1.12.3
OBJECT IDENTIFIER    

radAce101 1.3.6.1.4.1.164.6.1.12.3.1
OBJECT IDENTIFIER    

radAce102 1.3.6.1.4.1.164.6.1.12.3.2
OBJECT IDENTIFIER    

radAce50 1.3.6.1.4.1.164.6.1.12.3.3
OBJECT IDENTIFIER    

radSysLA 1.3.6.1.4.1.164.6.1.13
OBJECT IDENTIFIER    

radLA140 1.3.6.1.4.1.164.6.1.13.1
OBJECT IDENTIFIER    

radLA110 1.3.6.1.4.1.164.6.1.13.2
OBJECT IDENTIFIER    

radLA104 1.3.6.1.4.1.164.6.1.13.3
OBJECT IDENTIFIER    

radSysTerminal 1.3.6.1.4.1.164.6.1.100
OBJECT IDENTIFIER    

agnt 1.3.6.1.4.1.164.6.2
OBJECT IDENTIFIER    

agnHwVersion 1.3.6.1.4.1.164.6.2.1
ASCII string for description and display of the agent hardware version, as it is known by the agent software.The user can update the version upon request when he changes components in the agent's module
OBJECT-TYPE    
  DisplayString  

agnTrapMask 1.3.6.1.4.1.164.6.2.2
The value of this attribute determines the type of traps the agent should mask and not send to the management console. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
OBJECT-TYPE    
  Integer32  

agnTrapValue 1.3.6.1.4.1.164.6.2.3
The value of the trap decoded in internal RAD format. Full description is given in the Trap definition file
OBJECT-TYPE    
  OCTET STRING  

agnChangeCnt 1.3.6.1.4.1.164.6.2.4
The number of changes in system configuration that were reported to the manager since last cold start
OBJECT-TYPE    
  Counter32  

agnSpecific 1.3.6.1.4.1.164.6.2.5
Object identifier of entity containing additional information regarding this instance.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

agnConfigMsg 1.3.6.1.4.1.164.6.2.6
Full configuration message coded in internal RAD application format. This entry describes agent's configuration. For MP-2200 R3, this object describes agent's support of the V5.1 feature: 1 octet ; bit 0 (LSB). '1' - V5.1 feature is supported '0' - V5.1 feature is not supported.
OBJECT-TYPE    
  OCTET STRING  

mngTrapIpTable 1.3.6.1.4.1.164.6.2.7
This table indicates the destination address of the traps. Internally it will be limited to ten addresses.
OBJECT-TYPE    
  SEQUENCE OF  
    MngEntry

mngEntry 1.3.6.1.4.1.164.6.2.7.1
An entry in table.
OBJECT-TYPE    
  MngEntry  

mngID 1.3.6.1.4.1.164.6.2.7.1.1
This value indicates an index of a specific IP address
OBJECT-TYPE    
  Integer32  

mngIP 1.3.6.1.4.1.164.6.2.7.1.2
This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry.
OBJECT-TYPE    
  IpAddress  

mngIPMask 1.3.6.1.4.1.164.6.2.7.1.3
This value indicates the mask of the destination addresses of the traps.
OBJECT-TYPE    
  IpAddress  

mngTrapMask 1.3.6.1.4.1.164.6.2.7.1.4
The value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
OBJECT-TYPE    
  Integer32  

agnIndication 1.3.6.1.4.1.164.6.2.8
Attribute describing the state of the entity the agent is responsible for. In case of a modular entity, the value of this attribute will be according to the component which is in the worst state. The order of severity (from top to bottom) is: critical-> major (or faulty)-> minor-> event-> warning-> normal (off).
OBJECT-TYPE    
  INTEGER faulty(1), warning(2), normal(3), minor(4), major(5), event(6), critical(7)  

agnMonitorModeCmd 1.3.6.1.4.1.164.6.2.9
Setting this attribute to ON, will enforce the agent to change its mode of operation to Monitor Mode
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

agnLed 1.3.6.1.4.1.164.6.2.10
This entry specifies the LEDs status of the agent module . Each led will be represented by 4 bits where the first 2 bits (left) will specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) will specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY)
OBJECT-TYPE    
  OCTET STRING  

trapTable 1.3.6.1.4.1.164.6.2.11
This table includes the last few traps generated by the agent, for future retrieval. The table has a limited capacity. If traps are not retrieved in proper time, they will be over-written by new traps
OBJECT-TYPE    
  SEQUENCE OF  
    TrapEntry

trapEntry 1.3.6.1.4.1.164.6.2.11.1
An entry in table.
OBJECT-TYPE    
  TrapEntry  

trapID 1.3.6.1.4.1.164.6.2.11.1.1
This value indicates an index of a specific trap
OBJECT-TYPE    
  Integer32  

trapVal 1.3.6.1.4.1.164.6.2.11.1.2
This value is the actual ASCII description of the trap.
OBJECT-TYPE    
  DisplayString  

trapTimeSinceOccurrence 1.3.6.1.4.1.164.6.2.11.1.3
This value indicates the amount of time passed since the occurrence of the event that trigger this trap.
OBJECT-TYPE    
  TimeTicks  

fileTransfer 1.3.6.1.4.1.164.6.2.12
OBJECT IDENTIFIER    

fileServerIP 1.3.6.1.4.1.164.6.2.12.1
The IP address of the server from which the file is loaded
OBJECT-TYPE    
  IpAddress  

fileName 1.3.6.1.4.1.164.6.2.12.2
The name of the file to be loaded. For protection, read returns NULL.
OBJECT-TYPE    
  DisplayString  

fileTransCmd 1.3.6.1.4.1.164.6.2.12.3
The command to be executed on fileName at fileServerIP.
OBJECT-TYPE    
  INTEGER swDwnLoad(1), configDwnLoad(2), configUpLoad(3), coProcDwnLoad(4), stateUpLoad(5), dwnLoadUserFile(6), upLoadUserFile(7), swDwnLoadAndReset(8), noOp(255)  

tftpRetryTimeOut 1.3.6.1.4.1.164.6.2.12.4
General Retransmission time-out value (seconds)
OBJECT-TYPE    
  Integer32  

tftpTotalTimeOut 1.3.6.1.4.1.164.6.2.12.5
Total Retransmission time-out value (seconds)
OBJECT-TYPE    
  Integer32  

tftpStatus 1.3.6.1.4.1.164.6.2.12.6
Status of tftp session. When a session ended with success, the tftpStatus should be endedOk(6). Before restarting a tftp session, the NMS should set the tftpStatus to noOp(2). That's the reason of MAX-ACCESS read-write to this field.
OBJECT-TYPE    
  INTEGER noOp(2), connecting(3), transferringData(4), endedTimeOut(5), endedOk(6), error(7)  

tftpError 1.3.6.1.4.1.164.6.2.12.7
The MSB represents the standard error code. The LSB represents the private error code. 0x0000 is No Error 0x0100 is File Not Found 0x0400 is Illegal TFTP operation 0x0500 is Unknown transfer ID 0x0001 is Server Overflow 0x0002 is No empty UDP port 0x0003 is No empty connection 0x0004 is Illegal File Mode 0x0007 is Illegal PDU size
OBJECT-TYPE    
  OCTET STRING SIZE(2)  

fileTransferToSubSystems 1.3.6.1.4.1.164.6.2.12.8
This object represents the sub-systems the fileTransCmd refers to. It should be used when a system is divided to sub-systems and each sub-system (or part of them) can have a different SW/Configuration. Each bit of this object will represent one of the sub-systems. Bit='1' - APPLY to respective sub-system Bit='0' - DO NOT APPLY to respective sub-system For the meaning of each bit, see product's specification. User will select the sub-systems envolved by filling-in the bits that represent these sub-systems. In this case, the file represented by 'fileName' will include several parts, each representing one of the sub-systems. The agent will refer only to the part/s indicated by this object. 0 Octet Strings = not applicable DEFVAL = 0h for the products that support this object.
OBJECT-TYPE    
  OCTET STRING  

fileNameWithinProduct 1.3.6.1.4.1.164.6.2.12.9
The file name used by the product within the product file system.
OBJECT-TYPE    
  DisplayString  

intSwdlTable 1.3.6.1.4.1.164.6.2.12.10
This parameters table is for internal Software down load. It also includes data about all files contained in the Object from which down-load is performed.
OBJECT-TYPE    
  SEQUENCE OF  
    IntSwdlEntry

intSwdlEntry 1.3.6.1.4.1.164.6.2.12.10.1
An entry in table.
OBJECT-TYPE    
  IntSwdlEntry  

intSwdlObjIdx 1.3.6.1.4.1.164.6.2.12.10.1.1
The index of the object from which down-load is performed.
OBJECT-TYPE    
  Integer32  

intSwdlFileIdx 1.3.6.1.4.1.164.6.2.12.10.1.2
The index of the files included in intSwdlObjIdx. One of these files can be selected to be internally downloaded.
OBJECT-TYPE    
  Integer32  

intSwdlFileName 1.3.6.1.4.1.164.6.2.12.10.1.3
The name of the file.
OBJECT-TYPE    
  DisplayString  

intSwdlFileSwVer 1.3.6.1.4.1.164.6.2.12.10.1.4
The software version of the file.
OBJECT-TYPE    
  DisplayString  

intSwdlSwDate 1.3.6.1.4.1.164.6.2.12.10.1.5
The software version date of the file.
OBJECT-TYPE    
  DisplayString  

intSwdlSize 1.3.6.1.4.1.164.6.2.12.10.1.6
The size of the file.
OBJECT-TYPE    
  DisplayString  

intSwdlCmd 1.3.6.1.4.1.164.6.2.12.10.1.7
The command to down-load a SW file to an object. The Agent will change the value of this MIB object to off(2) automatically, after accepting the command.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

intSwdlToSubSystem 1.3.6.1.4.1.164.6.2.12.10.1.8
This object defines the subsystem for download. Bit='1'- APPLY to respective sub system. Bit='0'- DO NOT APPLY to respective sub system. For more details see product specification. For every octet bit0=LSB, bit7=MSB
OBJECT-TYPE    
  OCTET STRING  

swdlStatusTable 1.3.6.1.4.1.164.6.2.12.11
This parameters table is for software download status. It also includes data about the files down-loaded or attempted to be down-loaded.
OBJECT-TYPE    
  SEQUENCE OF  
    SwdlStatusEntry

swdlStatusEntry 1.3.6.1.4.1.164.6.2.12.11.1
An entry in table.
OBJECT-TYPE    
  SwdlStatusEntry  

swdlStatusTypeIdx 1.3.6.1.4.1.164.6.2.12.11.1.1
The index of the down-load type (e.g. external (1) or internal (2)).
OBJECT-TYPE    
  Integer32  

swdlStatusIdx 1.3.6.1.4.1.164.6.2.12.11.1.2
The index of the status rows.
OBJECT-TYPE    
  Integer32  

swdlStatusFileName 1.3.6.1.4.1.164.6.2.12.11.1.3
The name of the file.
OBJECT-TYPE    
  DisplayString  

swdlStatusSlot 1.3.6.1.4.1.164.6.2.12.11.1.4
The slot of the updated (or attempted to be updated) object.
OBJECT-TYPE    
  DisplayString  

swdlStatusSubSystem 1.3.6.1.4.1.164.6.2.12.11.1.5
The subsystem that updated (or attempted to be updated).
OBJECT-TYPE    
  DisplayString  

swdlStatusStatus 1.3.6.1.4.1.164.6.2.12.11.1.6
The status of the down load process. Value: Fail (2), OK (3), InProcess (4).
OBJECT-TYPE    
  Integer32  

swdlStatusTime 1.3.6.1.4.1.164.6.2.12.11.1.7
This MIB parameter indicates the time SW download was finished. The format shuld be YYYY-MM-DD, hh:mm:ss
OBJECT-TYPE    
  DisplayString  

clearDwldStatusLog 1.3.6.1.4.1.164.6.2.12.12
This object clears the status log. Value: off(2), external(3), internal(4) The Agent will change the value of this MIB object to off(2) automatically, after accepting the command .
OBJECT-TYPE    
  Integer32  

systemReset 1.3.6.1.4.1.164.6.2.13
Reset action to be performed on the system.
OBJECT-TYPE    
  INTEGER off(2), on(3), resetConfig(4)  

systemTiming 1.3.6.1.4.1.164.6.2.14
OBJECT IDENTIFIER    

systemDate 1.3.6.1.4.1.164.6.2.14.1
System date.
OBJECT-TYPE    
  DisplayString  

systemTime 1.3.6.1.4.1.164.6.2.14.2
System time.
OBJECT-TYPE    
  DisplayString  

systemPort 1.3.6.1.4.1.164.6.2.15
OBJECT IDENTIFIER    

physicalConnectorTable 1.3.6.1.4.1.164.6.2.15.1
This table includes the connector type of ports or interfaces.
OBJECT-TYPE    
  SEQUENCE OF  
    PhysicalConnectorEntry

physicalConnectorEntry 1.3.6.1.4.1.164.6.2.15.1.1
An entry in table.
OBJECT-TYPE    
  PhysicalConnectorEntry  

portIdx 1.3.6.1.4.1.164.6.2.15.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
OBJECT-TYPE    
  Integer32  

physicalConnector 1.3.6.1.4.1.164.6.2.15.1.1.2
The connector of the port/interface. other - none of the specified connectors none - no connector.
OBJECT-TYPE    
  INTEGER other(1), v35(2), rs530(3), x21(4), bnc(5), utp(6), aui(7), rs422(8), crossUtp(9), rj45(10), v24(11), g703(12), termBlock3AndRj45(13), terminalBlock3(14), terminalBlock5(15), terminalBlock7(16), db25(17), db15(18), rj45ethernet(19), termBlock5AndRj45(20), db9(21), g703E1(22), g703E1-LTU(23), sc(24), st(25), stl(26), fc(27), tb5w(28), termBlock6AndRj45(29), ethBnc(30), scsi26(31), eth4381(32), twoBnc(33), scsi50(34), twoMiniBnc(35), sf1(36), terminalBlock4(37), sf2(38), db25Balanced(39), v36(40), block4W(41), iripRj45(42), irEthQRj45(43), iripBnc(44), rs530WA(45), v35WA(46), irEthQBnc(47), v35Db25(48), rj11(49), mtrj(50), lc(51), terminalBlock2(52), irEth10s100(53), scsi68(54), sf3(55), fcLH(56), none(255)  

portOptWaveLength 1.3.6.1.4.1.164.6.2.15.1.1.3
Wave Length of an Optical interface/port in [nm] and specification if Laser LH,Laser or LED. notApplicable - for non-optical ports.
OBJECT-TYPE    
  INTEGER notApplicable(1), nm850(2), nm1300(3), nm1300Laser(4), nm1550Laser(5), nm1300LaserLH(6), nm1550LaserLH(7)  

portOptMode 1.3.6.1.4.1.164.6.2.15.1.1.4
Laser Mode of an Optical Laser interface/port. notApplicable - for non-Laser ports.
OBJECT-TYPE    
  INTEGER notApplicable(1), singleMode(2), multiMode(3)  

prtSupervisory 1.3.6.1.4.1.164.6.2.15.2
OBJECT IDENTIFIER    

prtSpTable 1.3.6.1.4.1.164.6.2.15.2.1
A table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSpEntry

prtSpEntry 1.3.6.1.4.1.164.6.2.15.2.1.1
Supervisory port parameter table.
OBJECT-TYPE    
  PrtSpEntry  

prtSupervisoryIndex 1.3.6.1.4.1.164.6.2.15.2.1.1.1
The SP port index. The LS byte of the integer is the port index 1..255. The MS byte is different than 0 only if the port belongs to a module. In that case it is the module number.
OBJECT-TYPE    
  Integer32  

prtSupervisoryRate 1.3.6.1.4.1.164.6.2.15.2.1.1.2
This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent.
OBJECT-TYPE    
  INTEGER auto(1), s300bps(2), s1200bps(3), s2400bps(4), s4800bps(5), s9600bps(6), s19200bps(7), s38400bps(8), s57600bps(9), s115200bps(10)  

prtSupervisoryDataBits 1.3.6.1.4.1.164.6.2.15.2.1.1.3
This attribute indicates the number of data bits in an async frame
OBJECT-TYPE    
  INTEGER dataBits7(1), dataBits8(2)  

prtSupervisoryParity 1.3.6.1.4.1.164.6.2.15.2.1.1.4
This attribute indicates the parity mode in an async frame
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3)  

prtSupervisoryStopBits 1.3.6.1.4.1.164.6.2.15.2.1.1.5
This attribute indicates the parity mode in an async frame.
OBJECT-TYPE    
  INTEGER notApplicable(1), stopBits1(2), stopBits1dot5(3), stopBits2(4)  

prtSupervisoryUsage 1.3.6.1.4.1.164.6.2.15.2.1.1.6
This attribute indicates the usage of the SP port.
OBJECT-TYPE    
  INTEGER unknown(1), noUse(2), terminal(3), nmsSlip(4), nmsPpp(5), muxSlip(6), muxPpp(7), dialOut(8)  

prtSupervisoryInterface 1.3.6.1.4.1.164.6.2.15.2.1.1.7
This attribute indicates the supervisory port interface.
OBJECT-TYPE    
  INTEGER notApplicable(1), dce(2), dte(3)  

prtSupervisoryCTS 1.3.6.1.4.1.164.6.2.15.2.1.1.8
CTS line state.
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3), dteWait(4), dteIgnore(5)  

prtSupervisoryDcdDelay 1.3.6.1.4.1.164.6.2.15.2.1.1.9
DCD delay in msec.
OBJECT-TYPE    
  INTEGER notApplicable(1), d0(2), d10(3), d50(4), d100(5), d200(6), d300(7)  

prtSupervisoryDSR 1.3.6.1.4.1.164.6.2.15.2.1.1.10
DSR line state.
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), dtr(3)  

prtSupervisoryRoutProtocol 1.3.6.1.4.1.164.6.2.15.2.1.1.11
This attribute indicates the routing protocol of the port. notApplicable - for DP.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtPerformance 1.3.6.1.4.1.164.6.2.15.3
OBJECT IDENTIFIER    

prtPerfTable 1.3.6.1.4.1.164.6.2.15.3.1
This table includes G.826 ports or interfaces.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPerfEntry

prtPerfEntry 1.3.6.1.4.1.164.6.2.15.3.1.1
An entry in table.
OBJECT-TYPE    
  PrtPerfEntry  

prtPerfIdx 1.3.6.1.4.1.164.6.2.15.3.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
OBJECT-TYPE    
  Integer32  

prtPerfPeriodRef 1.3.6.1.4.1.164.6.2.15.3.1.1.2
This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. lastPeriod - the period between last two commands of prtPerfSaveAndResetCmd. - If only one command occured since Start-up: the period between Start-up and last command. - If no command occured since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

prtPerfElapsedTime 1.3.6.1.4.1.164.6.2.15.3.1.1.3
Elapsed Time in seconds. - for prtPerfPeriodRef=currentPeriod: The period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. - for prtPerfPeriodRef=lastPeriod: The value of prtPerfElapsedTime when last prtPerfSaveAndResetCmd was received.
OBJECT-TYPE    
  Integer32  

prtPerfUAS 1.3.6.1.4.1.164.6.2.15.3.1.1.4
Number of Unavailable Seconds for the reference period (prtPerfPeriodRef).
OBJECT-TYPE    
  Integer32  

prtPerfES 1.3.6.1.4.1.164.6.2.15.3.1.1.5
Number of Errored Seconds for the reference period (prtPerfPeriodRef).
OBJECT-TYPE    
  Integer32  

prtPerfSES 1.3.6.1.4.1.164.6.2.15.3.1.1.6
Number of Severely Errored Seconds for the reference period (prtPerfPeriodRef).
OBJECT-TYPE    
  Integer32  

prtPerfBBE 1.3.6.1.4.1.164.6.2.15.3.1.1.7
Number of Background Block (or Frame) Errors for the reference period (prtPerfPeriodRef).
OBJECT-TYPE    
  Integer32  

prtPerfBlocksPerSec 1.3.6.1.4.1.164.6.2.15.3.1.1.8
Blocks per second (or frames per second) of the port/interface indicated by portIdx. This object is constant for a certain port/interface. It is not affected by the prtPerfPeriodRef index.
OBJECT-TYPE    
  Integer32  

prtPerfTimeTag 1.3.6.1.4.1.164.6.2.15.3.1.1.9
Time Tag of Last Period: sysUpTime when last prtPerfSaveAndResetCmd was executed. This object is applicable only for prtPerfPeriodRef=lastPeriod. For prtPerfPeriodRef=currentPeriod, the value will always be 0.
OBJECT-TYPE    
  TimeTicks  

prtPerfSaveAndResetCmd 1.3.6.1.4.1.164.6.2.15.3.1.1.10
A command per port/interface, to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. This object is applicable only for prtPerfPeriodRef=currentPeriod. Setting this object to on(3) for prtPerfPeriodRef=last, will cause the agent to return: Bad Value response. When setting validly this object to on(3), agent will perform the required command and will reset automatically the value of this object to off(2). Setting this object to off(2), will do nothing.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtTest 1.3.6.1.4.1.164.6.2.15.4
OBJECT IDENTIFIER    

prtTestTable 1.3.6.1.4.1.164.6.2.15.4.1
This table includes test data for ports or interfaces.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtTestEntry

prtTestEntry 1.3.6.1.4.1.164.6.2.15.4.1.1
An entry in table.
OBJECT-TYPE    
  PrtTestEntry  

prtTestIdx 1.3.6.1.4.1.164.6.2.15.4.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
OBJECT-TYPE    
  Integer32  

prtTestCmdAndStatus 1.3.6.1.4.1.164.6.2.15.4.1.1.2
Setting this object to a value as detailed further on (except 0) will initiate a test on the specific port. The test/s requested will be set according to the respective bit. The value of this object will be a sum of (2**n), where n is the Bit: TEST BIT VALUE ----------- --- ------ reserved 0 1 PayloadLoop=RLB 1 (=Remote Loopback) 2 LineLoop=DIG 2 (=Digital) 4 OtherLoop 3 8 InwardLoop=LLB 4 (=Local Loopback) 16 BERT 5 32 LC 6 64 ToneInjection 7 128 Inband 8 256 e.g : If the requested value is 20 -> 010100 -> Bits 2 & 4 are set -> the requested tests are : LineLoopback=DIG InwardLoopback=LLB Not all tests combinations are valid. For valid test combination, see each product's specification. For LRS52, only single test is allowed simultaneously The terminology and order of the first tests (except BERT) is according to the one used for Test Status of DS1 and DS3 standards. The notations : RLB, LLB, DIG are the most used in RAD's products, but they can be different. For exact definition see product's spec. Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port. When no test is running on the port, the Get value (test status) will be 0. PayloadLoop=RLB The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. LineLoop=DIG The received signal at this interface does not go through the device (minimum penetration) but is looped back out. OtherLoop Loopbacks that are not defined here. InwardLoop=LLB The sent signal at this interface is looped back through the device. LC This loop is applicable only for HSSI interface, towards the router . ToneInjection This loop is applicable for analog voice (like FXS).
OBJECT-TYPE    
  Integer32  

prtBertCounter 1.3.6.1.4.1.164.6.2.15.4.1.1.3
This object indicates the number of BERT errors encountered during the BERT operation. It is valid only when BERT (Bit Error Rate Test) is active on the specific port. The Counter starts from zero (0) anytime BERT is initiated.
OBJECT-TYPE    
  Integer32  

prtTestInitiator 1.3.6.1.4.1.164.6.2.15.4.1.1.4
This object indicates who initiated this port's test/s.
OBJECT-TYPE    
  INTEGER unknown(1), user(2), remoteUnit(3), dteRouter(4)  

prtTestTimeout 1.3.6.1.4.1.164.6.2.15.4.1.1.5
This object is applicable only when a single test is running. It indicates the test activation timeout in minutes. When the timeout expires, the test is stopped. Value of 0 indicates test may run Forever
OBJECT-TYPE    
  Integer32 0..4095  

prtParam 1.3.6.1.4.1.164.6.2.15.5
OBJECT IDENTIFIER    

prtParamTable 1.3.6.1.4.1.164.6.2.15.5.1
This table includes general port parameters. The meaning is different for every product that supports it due to a general parameter - prtControlCnfg. For ACE2002: This table is used as a mechanism to create the next interface index. The algorithm description: The NMS will send the agent the following get command: get(nextIfIndex.index), where index=interface on which the new index is dependent on. Upon this command the agent will generate and return the new index to the NMS.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtParamEntry

prtParamEntry 1.3.6.1.4.1.164.6.2.15.5.1.1
An entry in table.
OBJECT-TYPE    
  PrtParamEntry  

prtParamIdx 1.3.6.1.4.1.164.6.2.15.5.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used. For ACE2002: This parameter is the physical layer ifIndex of the slot on which the NMS requires the next interface index.
OBJECT-TYPE    
  Integer32  

prtControlCnfg 1.3.6.1.4.1.164.6.2.15.5.1.1.2
This object may be used for port RW general parameter/s. For detailed meaning, see product's spec. Supported by: PRBi-E3/T3. For ACE2002: This parameter will include the value of the new index generated by agent. For Optimux-T3: This parameter will be used for Release Remote LLB Command: on=2= Set value only. Command to release LLB of Remote Unit. Agent will return automatically to 'off' value after performing the command. off=3=Get value only. For LA140 This parameter will be used as EchoCanceler per timeslot off = 2 Echo Canceler is disabled on = 3 Echo Canceler is enabled
OBJECT-TYPE    
  Integer32  

prtParamClkSrc 1.3.6.1.4.1.164.6.2.15.5.1.1.3
The source of Transmit Clock. 'loopTiming' or 'loopback' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' or 'internal' indicates that a local clock source is used or when an external clock is attached to the box containing the interface. 'throughTiming' or 'external' indicates that recovered receive clock from another card or interface is used as the transmit clock. 'adaptive' indicates that the clock is recovered according to the received data flow rate.
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), throughTiming(3), adaptive(4), notApplicable(255)  

prtParamPhantom 1.3.6.1.4.1.164.6.2.15.5.1.1.4
Power feeding to another device.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtParamResetStatsCmd 1.3.6.1.4.1.164.6.2.15.5.1.1.5
Reset statistics of the selected port.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtParamLastResetStatsTime 1.3.6.1.4.1.164.6.2.15.5.1.1.6
The value of MIB II's sysUpTime object at the last time that prtParamResetStatsCmd was Set to on(3) for this port. If prtParamResetStatsCmd was never Set to on(3) since last re-initialization of the agent, then this object contains a zero value. This object enables calculating the running time of Statistics counters for this port, by: [sysUpTime-prtParamLastResetStatsTime].
OBJECT-TYPE    
  TimeStamp  

prtIP 1.3.6.1.4.1.164.6.2.15.6
OBJECT IDENTIFIER    

prtIpParamTable 1.3.6.1.4.1.164.6.2.15.6.1
A table - Parameters for IP Ports.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIpParamEntry

prtIpParamEntry 1.3.6.1.4.1.164.6.2.15.6.1.1
An entry in table.
OBJECT-TYPE    
  PrtIpParamEntry  

prtIpParamConfigIdx 1.3.6.1.4.1.164.6.2.15.6.1.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). For products having Agent and Edit configurations, Write operation for the table entries is allowed only to Config=255.
OBJECT-TYPE    
  Integer32  

prtIpParamSlotIdx 1.3.6.1.4.1.164.6.2.15.6.1.1.2
This object indicates a unique number of the slot position in which the module is inserted. notApplicable = 255 (for products that don't have slots). For KM: kmxMlA (103), kmxMlB (104).
OBJECT-TYPE    
  Integer32  

prtIpParamIdx 1.3.6.1.4.1.164.6.2.15.6.1.1.3
This object indicates a unique Port Index.
OBJECT-TYPE    
  Integer32  

prtIpParamHostIP 1.3.6.1.4.1.164.6.2.15.6.1.1.4
The host interface IP address.
OBJECT-TYPE    
  IpAddress  

prtIpParamHostMask 1.3.6.1.4.1.164.6.2.15.6.1.1.5
The host interface subnet mask.
OBJECT-TYPE    
  IpAddress  

prtIpParamDefaultGateway 1.3.6.1.4.1.164.6.2.15.6.1.1.6
Default Gateway's IP Address.
OBJECT-TYPE    
  IpAddress  

prtIpParamMediaMode 1.3.6.1.4.1.164.6.2.15.6.1.1.7
This object indicates the real Media Mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), halfDuplex(2), fullDuplex(3)  

prtIpParamMediaRate 1.3.6.1.4.1.164.6.2.15.6.1.1.8
This object indicates the real Media Rate (Mbps).
OBJECT-TYPE    
  INTEGER notApplicable(1), r10Mbps(2), r100Mbps(3)  

prtIpParamMngVlanSupport 1.3.6.1.4.1.164.6.2.15.6.1.1.9
Management VLAN support (Tagging). no - No support of VLAN Tagging. yes - 4 VLAN bytes will be added to the frame.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtIpParamMngVlanId 1.3.6.1.4.1.164.6.2.15.6.1.1.10
Management VLAN ID.
OBJECT-TYPE    
  Integer32  

prtIpParamMngVlanPriority 1.3.6.1.4.1.164.6.2.15.6.1.1.11
Management VLAN Frame priority.
OBJECT-TYPE    
  Integer32  

prtIpParamRingMode 1.3.6.1.4.1.164.6.2.15.6.1.1.12
This object indicates If Ring Mode is enabled or not.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

systemResetAllStatsCmd 1.3.6.1.4.1.164.6.2.16
Reset statistics of all ports and connections of the device.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

systemClearTablesCmd 1.3.6.1.4.1.164.6.2.17
tempCnfgTables - Set *RowStatus = destroy for all entries of some tables having *RowStatus object, for temporary configuration only! (255). For the relevant tables, see product's specification. This object should be used by WAN product applications before performing the Update operation, in order to clear old entries of these tables. off - agent will automatically change to this value, after performing the command.
OBJECT-TYPE    
  INTEGER off(2), tempCnfgTables(3)  

systemParameter 1.3.6.1.4.1.164.6.2.18
This parameter can be used for different purposes: - TELNET session time-out in seconds. - Ace20: when trying to create row in a table that already has row with the same values, if set of values has to be unique in table, this attribute is set to the index of the existing row. - Optimux-T3: when CH interfaces are RJ-45, user can select via this object, the interface type for each Group of channels: T1 or E1: The selection will be a sum of the following Bits. '0' = T1 '1' = E1 Bit Group Value for each Bit having '1' 1 1 (CH-1..CH-8) 1 2 2 (CH-9..CH-12) 2 3 3 (CH-13..CH-20) 4 4 4 (CH-21..CH-28) 8 Examples: 15 = all Groups are selected to be E1 6 = Group 2 and Group 3 are selected to be E1 (Group 1 and Group 4 are T1). - FCD-A, FCD-M: user can select via this object the configuration used for Get values of MSDSL parameters that don't have configuration index. 1 =active configuration 255=temporary configuration. Set of this object should be done before Getting the MSDSL RW parameters. - Ace2002: This parameter indicates the number of intervals that were successfully uploaded upon statistics collection session. - FCD-IP, WR, FCD-IPD, LA-240: This parameter indicates whether Telnet Access is enabled/disabled: Values: 2 - Telnet Access is Disabled. 3 - Telnet Access is Enabled. - Vmux-110: This parameter value equals maximum number of bundles.
OBJECT-TYPE    
  Integer32  

agnGlobalAlarmMask 1.3.6.1.4.1.164.6.2.19
The value of this attribute determines the alarm traps the agent should mask and not send to the managers. Each bit from a certain octet represents a certain alarm.
OBJECT-TYPE    
  OCTET STRING  

alarmSeverity 1.3.6.1.4.1.164.6.2.20
This object specifies the severity of the alarms.
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

alarmState 1.3.6.1.4.1.164.6.2.21
.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnTestStatus 1.3.6.1.4.1.164.6.2.22
Indicates the current test status (for all levels: system, card, port). This attribute will be set to: on(3): when there is at least one test in progress on the system/card/port off(2): when there is NO test in progress on the system/card/port
OBJECT-TYPE    
  INTEGER off(2), on(3)  

systemSaveAndResetAllStatsCmd 1.3.6.1.4.1.164.6.2.23
on - a command to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. off - agent will automatically change to this value, after performing the command.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

systemDefaultGateway 1.3.6.1.4.1.164.6.2.24
Default Gateway's IP Address.
OBJECT-TYPE    
  IpAddress  

systemPsTable 1.3.6.1.4.1.164.6.2.25
This table describes the PS types of a device. Usage of this table is specified in the device's NMS SRS
OBJECT-TYPE    
  SEQUENCE OF  
    SystemPsEntry

systemPsEntry 1.3.6.1.4.1.164.6.2.25.1
An entry in table.
OBJECT-TYPE    
  SystemPsEntry  

systemPsIndex1 1.3.6.1.4.1.164.6.2.25.1.1
First Index. In HUBs: 1 = PS-A slot 2 = PS-B slot. In SA units: 1 = PS1 2 = PS2 Default = 1
OBJECT-TYPE    
  Integer32  

systemPsIndex2 1.3.6.1.4.1.164.6.2.25.1.2
Second Index. In HUBs: 1 always. In SA units: 1 = Local 2 = Remote Default = 1.
OBJECT-TYPE    
  Integer32  

systemPsType 1.3.6.1.4.1.164.6.2.25.1.3
The type of PS, for a stand-alone product. acDc - AC with rj45 DC. acPF - Power Feeding (phantom) box that is feeding another box by external AC. dcPF - Power Feeding (phantom) box that is feeding another box by external DC.
OBJECT-TYPE    
  INTEGER none(1), ac(2), dc(3), acDc(4), acPF(5), dcPF(6)  

systemPsStatus 1.3.6.1.4.1.164.6.2.25.1.4
The Status of the PS unit.
OBJECT-TYPE    
  INTEGER notApplicable(1), failed(2), ok(3)  

systemPsHotSwap 1.3.6.1.4.1.164.6.2.25.1.5
Is PS unit hot swap or fixed.
OBJECT-TYPE    
  INTEGER notApplicable(1), fixed(2), hotSwap(3)  

agnFans 1.3.6.1.4.1.164.6.2.26
This entry specifies the FANs existence and status. Each fan will be represented by 2 bits, where the first bit (right) will specify the existence: (0= Not exist, 1=exist), and the left bit will specify it's status (0= OK, 1=FAIL), so for each fan: 00 - FAN does not exist 01 - FAN exists and OK 11 - FAN exists and is Failed bits 0-1 are for first fan bits 2-3 are for 2nd fan (if exists).
OBJECT-TYPE    
  OCTET STRING  

agnSendTrapParameter 1.3.6.1.4.1.164.6.2.27
This object specifies if the agent will attach a specific parameter to a trap. For ACE2002 the agent will attach or not the openViewSeverity parameter according to the value of this parameter: 1 - will attach openViewSeverity. 0 - will not attach openViewSeverity.
OBJECT-TYPE    
  Integer32  

xcIndexNext 1.3.6.1.4.1.164.6.2.30
This object contains an appropriate value to be used for xcIndex when creating entries in the xcTable. The value 0 indicates that no unassigned entries are available. To obtain the xcIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index. After a manager retrieves a value the agent will determine through its local policy when this index value will be made available for reuse.
OBJECT-TYPE    
  Integer32 0..2147483647  

xcTable 1.3.6.1.4.1.164.6.2.31
Configuration of system cross-connect entries. The table follows the behavior described in RFC 2515, RFC 1604 regarding the creation deletion and modification of an entry within the table.
OBJECT-TYPE    
  SEQUENCE OF  
    XcEntry

xcEntry 1.3.6.1.4.1.164.6.2.31.1
An entry in table.
OBJECT-TYPE    
  XcEntry  

xcIndex 1.3.6.1.4.1.164.6.2.31.1.1
Cross Connect Identifier.
OBJECT-TYPE    
  Integer32  

xcIfIndex1 1.3.6.1.4.1.164.6.2.31.1.2
The interface Index from the ifTable, which identify one side of the connection.
OBJECT-TYPE    
  Integer32  

xcVpi 1.3.6.1.4.1.164.6.2.31.1.3
The VPI of the ATM End-Point.
OBJECT-TYPE    
  Integer32  

xcVci 1.3.6.1.4.1.164.6.2.31.1.4
The VCI of the ATM End-Point.
OBJECT-TYPE    
  Integer32  

xcIfIndex2 1.3.6.1.4.1.164.6.2.31.1.5
The interface Index from the ifTable, which identifies the other side of the connection.
OBJECT-TYPE    
  Integer32  

xcRowStatus 1.3.6.1.4.1.164.6.2.31.1.6
This parameter allows NMS to create/delete entries of this table.
OBJECT-TYPE    
  RowStatus  

xcDescr 1.3.6.1.4.1.164.6.2.31.1.7
A textual string containing information about the xc entry.
OBJECT-TYPE    
  DisplayString  

xcAdminStatus 1.3.6.1.4.1.164.6.2.31.1.8
The desired administrative status of this bi-directional cross-connect.
OBJECT-TYPE    
  INTEGER up(1), down(2)  

xcOperStatus 1.3.6.1.4.1.164.6.2.31.1.9
The operational status of this bi-directional cross-connect.
OBJECT-TYPE    
  INTEGER up(1), down(2), unknown(3)  

systemModule 1.3.6.1.4.1.164.6.2.32
OBJECT IDENTIFIER    

modlParam 1.3.6.1.4.1.164.6.2.32.1
OBJECT IDENTIFIER    

modlParamTable 1.3.6.1.4.1.164.6.2.32.1.1
This table include parameters for system modules.
OBJECT-TYPE    
  SEQUENCE OF  
    ModlParamEntry

modlParamEntry 1.3.6.1.4.1.164.6.2.32.1.1.1
An entry in table.
OBJECT-TYPE    
  ModlParamEntry  

modlParamIndex 1.3.6.1.4.1.164.6.2.32.1.1.1.1
The module index. The index can be the slot number or any other module index as described in the specifications of the device. For Vmux-2100 device, the index will have values of: 1..4 for slots 1..4.
OBJECT-TYPE    
  Integer32  

modlParamReset 1.3.6.1.4.1.164.6.2.32.1.1.1.2
Reset action to be performed on the module. Set the parameter will be done always to on(3) or factory (4). After performing the Reset operation, Agent will automatically set the parameter to off(2).
OBJECT-TYPE    
  INTEGER off(2), on(3), factory(4)  

modlParamSwdlStatus 1.3.6.1.4.1.164.6.2.32.1.1.1.3
This parameter indicates whatever the swdl is in process or not.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), inProcess(3)  

modlParamLeds 1.3.6.1.4.1.164.6.2.32.1.1.1.4
This entry specifies the LEDs status of the module. Each led is represented by 4 bits where the first 2 bits (left) specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY). The order of the LEDS is from top to bottom, left to right: For each row starting from the top, the LEDS are returned from left to right.
OBJECT-TYPE    
  OCTET STRING  

agnNearFarConnection 1.3.6.1.4.1.164.6.2.33
This parameter describes the connection between near-end and far-end agents.
OBJECT-TYPE    
  INTEGER notApplicable(1), disconnected(2), connected(3)  

agnAccess 1.3.6.1.4.1.164.6.2.34
OBJECT IDENTIFIER    

agnTelnetAccess 1.3.6.1.4.1.164.6.2.34.1
Enable/Disable accessing the device via Telnet. disable - no one will be allowed to access the device via Telnet. enable - all users are allowed Telnet Access. managersOnly - Only manager stations listed in the manager's list are allowed.
OBJECT-TYPE    
  INTEGER disable(2), enable(3), managersOnly(4)  

radStkHub 1.3.6.1.4.1.164.7
OBJECT IDENTIFIER    

radStkHubEvents 1.3.6.1.4.1.164.7.0
The events for Rad Stackable General products.
OBJECT-IDENTITY    

portStatusChanged 1.3.6.1.4.1.164.7.0.26
This trap is sent each time port status was changed.
NOTIFICATION-TYPE    
  stkHubETMdlLed  
  rpMauMediaAvailable  
  rptrPortOperStatus  

softErrors 1.3.6.1.4.1.164.7.0.33
This trap is sent when the software errors threshold is exceeded.
NOTIFICATION-TYPE    

stkHubGen 1.3.6.1.4.1.164.7.1
OBJECT IDENTIFIER    

stkHubGenAgn 1.3.6.1.4.1.164.7.1.1
OBJECT IDENTIFIER    

stkHubAgentResetConfig 1.3.6.1.4.1.164.7.1.1.1
Setting the value to ON(3)is interpreted as a reset command for the agent NV Ram. When reset process is ended, a trap will be issued.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

stkHubAgentSpecific 1.3.6.1.4.1.164.7.1.1.2
Object identifier of entity containing additional information regarding this instance.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

stkHubSecurityTable 1.3.6.1.4.1.164.7.1.2
Hub's Security parameters.
OBJECT-TYPE    
  SEQUENCE OF  
    StkHubSecurityEntry

stkHubSecurityEntry 1.3.6.1.4.1.164.7.1.2.1
An entry in table stkHubSecurityTable.
OBJECT-TYPE    
  StkHubSecurityEntry  

stkHubSecID 1.3.6.1.4.1.164.7.1.2.1.1
Segment's security unique identification number
OBJECT-TYPE    
  Integer32 1..3  

stkHubSecEnable 1.3.6.1.4.1.164.7.1.2.1.2
This entry indicates whether the specific segment's security is active or not
OBJECT-TYPE    
  INTEGER off(2), on(3)  

stkHubSecurityPattern 1.3.6.1.4.1.164.7.1.2.1.3
A six-octet(48 bit) pattern: where the masked bits of stkHubSecurityMask need to match the MAC address of each port within the segment.Value of all zeros indicates no security.
OBJECT-TYPE    
  OCTET STRING  

stkHubSecurityMask 1.3.6.1.4.1.164.7.1.2.1.4
Mask of the allowed MAC address that can be connected through the ports within the segment
OBJECT-TYPE    
  OCTET STRING  

stkHubPrtSecurityTable 1.3.6.1.4.1.164.7.1.3
Port Security parameters.
OBJECT-TYPE    
  SEQUENCE OF  
    StkHubPrtSecurityEntry

stkHubPrtSecurityEntry 1.3.6.1.4.1.164.7.1.3.1
An entry in table stkHubPrtSecurityTable.
OBJECT-TYPE    
  StkHubPrtSecurityEntry  

stkHubModuleID 1.3.6.1.4.1.164.7.1.3.1.1
A unique identifier of the module(slot no.)this port is attached to.
OBJECT-TYPE    
  Integer32  

stkHubPrtID 1.3.6.1.4.1.164.7.1.3.1.2
A unique identifier of the port within its module.
OBJECT-TYPE    
  Integer32  

stkHubPrtSecID 1.3.6.1.4.1.164.7.1.3.1.3
A unique identifier of the security of a given port within its module.
OBJECT-TYPE    
  Integer32  

stkHubPrtSecurityEnable 1.3.6.1.4.1.164.7.1.3.1.4
The value of this attribute determines application of the port security.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

stkHubPrtSecurityPattern 1.3.6.1.4.1.164.7.1.3.1.5
A six-octet(48 bit) pattern: where the masked bits of stkHubPortSecurityMask need to match the MAC address.
OBJECT-TYPE    
  OCTET STRING  

stkHubPrtSecurityMask 1.3.6.1.4.1.164.7.1.3.1.6
Mask of the allowed MAC address that can be connected through this port. The security of the individual port over writes the security of the segment where the port belongs to
OBJECT-TYPE    
  OCTET STRING  

stkHubTR 1.3.6.1.4.1.164.7.2
OBJECT IDENTIFIER    

stkHubTREvents 1.3.6.1.4.1.164.7.2.0
The events for Stackable Token Ring.
OBJECT-IDENTITY    

mdlStatusChanged 1.3.6.1.4.1.164.7.2.0.27
This trap is sent each time module status was changed.When a module is disconnected, the stkHubTRMdlLed status will be 00 (no led) and the stkHubTRMdlType will be empty(255).
NOTIFICATION-TYPE    
  stkHubTRMdlLed  
  stkHubTRMdlType  

macAddressUpdated 1.3.6.1.4.1.164.7.2.0.91
This trap will be sent upon every change of MACAddress on a port.
NOTIFICATION-TYPE    
  stkHubTRPrtMACAddress  

stkHubTRRing 1.3.6.1.4.1.164.7.2.1
OBJECT IDENTIFIER    

stkHubTRRingCorrelationEnable 1.3.6.1.4.1.164.7.2.1.1
When set to ON(3), the in-band agent should perform correlation each time a station enters/leaves the segment.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

stkHubTRRingAutorecEnable 1.3.6.1.4.1.164.7.2.1.2
When set to ON(3), the in-band agent should perform autorecovery each time a beacon status is detected.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

stkHubTRRingAutorecResult 1.3.6.1.4.1.164.7.2.1.3
When autorecovery is completed the result will be recorded. While in process, STARTED will be recorded.Before process, NOT STARTED will be recorded
OBJECT-TYPE    
  INTEGER not-started(1), started(2), segment-ok(3), segment-fixed(4), segment-closed(5), failed(6)  

stkHubTRRingResetStatistics 1.3.6.1.4.1.164.7.2.1.4
Setting the value of this attribute to ON(3) resets all the inband statistics and error counters.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

stkHubTRRingLineErrCnt 1.3.6.1.4.1.164.7.2.1.5
This counter is incremented when a frame or token is copied or repeated by any of the stations on the ring, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame.
OBJECT-TYPE    
  Counter32  

stkHubTRRingBurstErrCnt 1.3.6.1.4.1.164.7.2.1.6
This counter is incremented when any of the stations on the ring detects the absence of transitions for five half-bit timers (burst-five error).
OBJECT-TYPE    
  Counter32  

stkHubTRRingACFCErrCnt 1.3.6.1.4.1.164.7.2.1.7
This counter is incremented when any of the stations on the ring receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly.
OBJECT-TYPE    
  Counter32  

stkHubTRRingTotErrCnt 1.3.6.1.4.1.164.7.2.1.8
The total of the above described errors
OBJECT-TYPE    
  Counter32  

stkHubTRRingTotErrThreshold 1.3.6.1.4.1.164.7.2.1.9
The Total Errors Threshold value. A trap indicating Soft Error will be sent, if the total number of errors during the last 10 seconds, reached the threshold value. Threshold value = 0 , disables this trap.
OBJECT-TYPE    
  Integer32  

stkHubTRRingTotalFrames 1.3.6.1.4.1.164.7.2.1.10
The total frames of the Ring.
OBJECT-TYPE    
  Counter32  

stkHubTRRingTotalFramesRate 1.3.6.1.4.1.164.7.2.1.11
The rate of total frames on the Ring.
OBJECT-TYPE    
  Integer32  

stkHubTRRingTotalOctets 1.3.6.1.4.1.164.7.2.1.12
The total octets of the Ring.
OBJECT-TYPE    
  Counter32  

stkHubTRRingOctetsRatio 1.3.6.1.4.1.164.7.2.1.13
Current traffic for the last time interval. The traffic is expressed in percents of the maximum TokenRing traffic .
OBJECT-TYPE    
  Integer32  

stkHubTRMdl 1.3.6.1.4.1.164.7.2.2
OBJECT IDENTIFIER    

stkHubTRMdlTable 1.3.6.1.4.1.164.7.2.2.1
Bridge Hub Module table for TR media type Contains general information about the Module
OBJECT-TYPE    
  SEQUENCE OF  
    StkHubTRMdlEntry

stkHubTRMdlEntry 1.3.6.1.4.1.164.7.2.2.1.1
An entry in table stkHubTRMdlTable.
OBJECT-TYPE    
  StkHubTRMdlEntry  

stkHubTRMdlID 1.3.6.1.4.1.164.7.2.2.1.1.1
A unique identifier of the module in stack. Internal module identifier is always 1
OBJECT-TYPE    
  Integer32 1..10  

stkHubTRMdlType 1.3.6.1.4.1.164.7.2.2.1.1.2
Indicates the type of the module connected with specific identifier
OBJECT-TYPE    
  INTEGER unknown(1), sah16int(2), sah16ext(3), empty(255)  

stkHubTRMdlReset 1.3.6.1.4.1.164.7.2.2.1.1.3
When this object is set to the value of ON(3), the module performs software reset. Upon completion, a trap will be issued to the management station and the value will be set to OFF.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

stkHubTRMdlLed 1.3.6.1.4.1.164.7.2.2.1.1.4
This entry specifies the LEDs status in the module . Each led will be represented by 4 bits where the first 2 bits will specify the status (NA, OFF, ON, BLINK), and the next two bits will specify the color (RED, GREEN, YELLOW)
OBJECT-TYPE    
  OCTET STRING  

stkHubTRMdlSpeed 1.3.6.1.4.1.164.7.2.2.1.1.5
Attribute describing the bandwidth of the media as set by the module switch. For certain products, if the value of stkHubTRMdlMngState is 'enabled', then stkHubTRMdlSpeed can be set to the desired value. Else, it will be read-only, and will show the status of the jumper set of the main module. Refer product's manual.
OBJECT-TYPE    
  INTEGER unknown(1), fourMegabit(2), sixteenMegabit(3)  

stkHubTRMdlMngState 1.3.6.1.4.1.164.7.2.2.1.1.6
This object indicates the status of the Manage switch as set on the back panel of the main module. 'enabled' - means that management can override setting of some HW switch/es.
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), enabled(3)  

stkHubTRMdlAutodisable 1.3.6.1.4.1.164.7.2.2.1.1.7
Attribute describing the status of port Autodisable mechanism, that protects against inserting in Token Ring adapters at the wrong speed. For certain products, if the value of stkHubTRMdlMngState is 'enabled', then stkHubTRMdlAutodisable can be set to the desired value. Else, it will be read-only, and will show the status of the jumper set of the main module. Refer product's manual.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

stkHubTRMdlConfigMsg 1.3.6.1.4.1.164.7.2.2.1.1.8
Full configuration message coded in internal RND application format. This entry describes module' configuration.
OBJECT-TYPE    
  OCTET STRING  

stkHubTRPrt 1.3.6.1.4.1.164.7.2.3
OBJECT IDENTIFIER    

stkHubTRPrtTable 1.3.6.1.4.1.164.7.2.3.1
Bridge Hub port table for TR media type Contains general information about the ports.
OBJECT-TYPE    
  SEQUENCE OF  
    StkHubTRPrtEntry

stkHubTRPrtEntry 1.3.6.1.4.1.164.7.2.3.1.1
An entry in table stkHubTRPrtTable.
OBJECT-TYPE    
  StkHubTRPrtEntry  

stkHubTRPrtMdlID 1.3.6.1.4.1.164.7.2.3.1.1.1
A unique identifier of the module this port is attached to.
OBJECT-TYPE    
  Integer32  

stkHubTRPrtID 1.3.6.1.4.1.164.7.2.3.1.1.2
A unique identifier of the port within its module.
OBJECT-TYPE    
  Integer32  

stkHubTRPrtFunctionality 1.3.6.1.4.1.164.7.2.3.1.1.3
Describes the functionality of the port in a Token ring topology
OBJECT-TYPE    
  INTEGER unknown(1), ringin(2), ringout(3), satellite(4), lobe(5)  

stkHubTRPrtConnectorType 1.3.6.1.4.1.164.7.2.3.1.1.4
Type of hardware connector in the port.
OBJECT-TYPE    
  INTEGER notApplicable(1), idc(2), rj45(3), srJ45(4), db9(5), bnc(6), fo-st(7), db25(8)  

stkHubTRPrtAdminCmd 1.3.6.1.4.1.164.7.2.3.1.1.5
By setting this attribute to DISABLE(2) or SHORT(4) the management station can force this lobe/port-connection to be removed and block any access to the network via this lobe/port. It is not mandatory that a certain lobe/port will support all the enumerated states. The state of the lobe/port is type specific and indicated within the specific group
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3), short(4), normal(5)  

stkHubTRPrtActiveState 1.3.6.1.4.1.164.7.2.3.1.1.6
This attribute describes the electrical or optical activity state of a lobe or the state of a port. Certain values may not be applicable in some cases
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3), standby(4)  

stkHubTRPrtTrapMaskEnable 1.3.6.1.4.1.164.7.2.3.1.1.7
When this attribute is set to OFF by the management console the agent starts sending the unmasked traps related to this port. Otherwise no traps from this port are sent.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

stkHubTRPrtStatus 1.3.6.1.4.1.164.7.2.3.1.1.8
This attribute indicates the status of this lobe/port connection: DISABLED-(2) to (6) indicates the reason for the disabled state. INSERTED(7)indicates that the lobe hardware inserts this lobe into the ring , thus it becomes part of the ring BYPASSED(8)indicates that the ring bypasses this lobe and the lobe hardware provides loopback connection towards the station for media test purposes. FORCEDLOOP(9) indicates the port is in a loopback state and the main ring is connected to the backup path. TRUNKFAIL (10) indicates that the ring connection is broken for a repeater, converter or a cable protector. NORMAL(11) indicates the port is in normal condition It is not mandatory that a certain lobe/port will support all the enumerated states.
OBJECT-TYPE    
  INTEGER unknown(1), disabledManual(2), disabledAutorec(3), disabledSecurity(4), disabledAuto(5), disabledFlip(6), inserted(7), bypass(8), forcedloop(9), trunkfail(10), normal(11)  

stkHubTRPrtCableProtectEnable 1.3.6.1.4.1.164.7.2.3.1.1.9
The value of this attribute determines activation of the cable-fault protection mechanism of TCR and the optical link mechanism of TFR and TFC .
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3), inhibit(4)  

stkHubTRPrtFlipProtectEnable 1.3.6.1.4.1.164.7.2.3.1.1.10
The value of this attribute determines activation of the flipping-lobe protection mechanism of the port.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

stkHubTRPrtMACAddress 1.3.6.1.4.1.164.7.2.3.1.1.11
The value of this object is the specific MAC address of this interface which uniquely identifies this Interface on a ring.
OBJECT-TYPE    
  MacAddress  

stkHubTRPrtType 1.3.6.1.4.1.164.7.2.3.1.1.12
Type of the port specific hardware
OBJECT-TYPE    
  INTEGER notApplicable(1), tfr(2), tfc(3), tcr(4), tcp(5)  

stkHubET 1.3.6.1.4.1.164.7.3
OBJECT IDENTIFIER    

stkHubETMdl 1.3.6.1.4.1.164.7.3.2
OBJECT IDENTIFIER    

stkHubETMdlTable 1.3.6.1.4.1.164.7.3.2.1
Bridge Hub Module table for ET media type Contains general information about the Module
OBJECT-TYPE    
  SEQUENCE OF  
    StkHubETMdlEntry

stkHubETMdlEntry 1.3.6.1.4.1.164.7.3.2.1.1
An entry in table stkHubETMdlTable.
OBJECT-TYPE    
  StkHubETMdlEntry  

stkHubETMdlID 1.3.6.1.4.1.164.7.3.2.1.1.1
A unique identifier of the module in stack. Internal module identifier is always 1
OBJECT-TYPE    
  Integer32 1..10  

stkHubETMdlLed 1.3.6.1.4.1.164.7.3.2.1.1.2
This entry specifies the LEDs status in the module . Each led will be represented by 4 bits where the first 2 bits will specify the status (NA, OFF, ON, BLINK), and the next two bits will specify the color (RED, GREEN, YELLOW)
OBJECT-TYPE    
  OCTET STRING  

stkHubETMdlReset 1.3.6.1.4.1.164.7.3.2.1.1.3
When this object is set to the value of hwReset(3), the module performs HW reset. When this object is set to the value of configReset(4), the module performs Configuration reset. Upon completion, a trap will be issued to the management station and the value will be set to OFF.
OBJECT-TYPE    
  INTEGER unknown(1), off(2), hwReset(3), configReset(4)  

radPS 1.3.6.1.4.1.164.8
OBJECT IDENTIFIER    

pktSwchSystem 1.3.6.1.4.1.164.8.1
OBJECT IDENTIFIER    

pktSwchSysParam 1.3.6.1.4.1.164.8.1.1
OBJECT IDENTIFIER    

pktSwchSysSParam 1.3.6.1.4.1.164.8.1.1.1
OBJECT IDENTIFIER    

pktSwchSysX28PromptS 1.3.6.1.4.1.164.8.1.1.1.1
This specifies a different PAD prompt, instead of the standard default character, the *. Up to 10 characters can be entered.
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

pktSwchSysHeraldS 1.3.6.1.4.1.164.8.1.1.1.2
This specifies the PAD herald message for the SPS-6 and SPS-12. Up to 32 characters can be entered. Other devices will return a zero length octet string and will send an error if this object is set to a string of any other length.
OBJECT-TYPE    
  DisplayString SIZE(0..32)  

pktSwchSysBulletinS 1.3.6.1.4.1.164.8.1.1.1.3
This specifies the PAD bulletin message. Up to 32 characters can be entered.
OBJECT-TYPE    
  DisplayString SIZE(0..32)  

pktSwchSysComPortSubAddS 1.3.6.1.4.1.164.8.1.1.1.4
This is the scratch command port with the desired subaddress.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchSysComPortAltSubAddS 1.3.6.1.4.1.164.8.1.1.1.5
This configures the command port with the second subaddress.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchSysInnerCommLenS 1.3.6.1.4.1.164.8.1.1.1.6
This specifies the address length in digits for Inner Communication.
OBJECT-TYPE    
  Integer32 1..5  

pktSwchSysXOnCharS 1.3.6.1.4.1.164.8.1.1.1.7
The ASCII code of the software flow control character that will be used to start/renew the data transfer.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchSysXOffCharS 1.3.6.1.4.1.164.8.1.1.1.8
The ASCII code of the software flow control character that will be used to stop the data transfer.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchSysMaxLcnS 1.3.6.1.4.1.164.8.1.1.1.9
The maximum number of LCNs on the device.
OBJECT-TYPE    
  Integer32  

pktSwchSysMaxAIDS 1.3.6.1.4.1.164.8.1.1.1.10
The maximum number of AIDs on the device.
OBJECT-TYPE    
  Integer32  

pktSwchSysDeviceIdS 1.3.6.1.4.1.164.8.1.1.1.11
The device Id.
OBJECT-TYPE    
  DisplayString  

pktSwchSysAParam 1.3.6.1.4.1.164.8.1.1.2
OBJECT IDENTIFIER    

pktSwchSysX28PromptA 1.3.6.1.4.1.164.8.1.1.2.1
This specifies the active PAD prompt.
OBJECT-TYPE    
  DisplayString SIZE(0..10)  

pktSwchSysHeraldA 1.3.6.1.4.1.164.8.1.1.2.2
This specifies the active PAD herald message for the SPS-6 and SPS-12. Other devices will return a zero length string.
OBJECT-TYPE    
  DisplayString SIZE(0..32)  

pktSwchSysBulletinA 1.3.6.1.4.1.164.8.1.1.2.3
This indicates the active PAD bulletin message.
OBJECT-TYPE    
  DisplayString SIZE(0..32)  

pktSwchSysComPortSubAddA 1.3.6.1.4.1.164.8.1.1.2.4
This is the active command port with the desired subaddress.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchSysComPortAltSubAddA 1.3.6.1.4.1.164.8.1.1.2.5
This is the active command port with the second subaddress.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchSysInnerCommLenA 1.3.6.1.4.1.164.8.1.1.2.6
This specifies the active address length in digits for Inner Communication.
OBJECT-TYPE    
  Integer32 1..5  

pktSwchSysXOnCharA 1.3.6.1.4.1.164.8.1.1.2.7
The activeASCII code of the software flow control character that is used to start/renew the data transfer.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchSysXOffCharA 1.3.6.1.4.1.164.8.1.1.2.8
The active ASCII code of the software flow control character that is used to stop the data transfer.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchSysMaxLcnA 1.3.6.1.4.1.164.8.1.1.2.9
The active maximum number of LCNs on the device.
OBJECT-TYPE    
  Integer32  

pktSwchSysMaxAIDA 1.3.6.1.4.1.164.8.1.1.2.10
The active maximum number of AIDs on the device.
OBJECT-TYPE    
  Integer32  

pktSwchSysDeviceIdA 1.3.6.1.4.1.164.8.1.1.2.11
The device Id.
OBJECT-TYPE    
  DisplayString  

pktSwchSysEvRepS 1.3.6.1.4.1.164.8.1.1.3
OBJECT IDENTIFIER    

pktSwchSysEvRepAdd1S 1.3.6.1.4.1.164.8.1.1.3.1
This specifies the X.25 address to which the reports selected by means of pktSwchSysEvRepMask1S and pktSwchSysEvRepPeriod1S will be sent.
OBJECT-TYPE    
  DisplayString  

pktSwchSysEvRepAdd2S 1.3.6.1.4.1.164.8.1.1.3.2
This specifies the X.25 address to which the reports selected by means of pktSwchSysEvRepMask2S and pktSwchSysEvRepPeriod2S will be sent.
OBJECT-TYPE    
  DisplayString  

pktSwchSysEvRepMask1S 1.3.6.1.4.1.164.8.1.1.3.3
This specifies the conditions on which reports are sent to the address specified in pktSwchSysEvRepAdd1S. The value is a sum of values (powers of two), where each value in the sum represents a condition. The values that may be included in the sum and their meanings are: 0 Disable event reports 1 Send report when SYNC status has changed 2 Send report when RTS status has changed 4 Send report at Power On (Reset) 8 Report charging information at CLR.
OBJECT-TYPE    
  Integer32 0..15  

pktSwchSysEvRepPeriod1S 1.3.6.1.4.1.164.8.1.1.3.4
This specifies the time interval in minutes at which periodic reports are sent to the address specified in pktSwchSysEvRepAdd1S. A value of zero indicates that periodic reports are disabled.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchSysEvRepMask2S 1.3.6.1.4.1.164.8.1.1.3.5
This specifies the conditions on which reports are sent to the address specified in pktSwchSysEvRepAdd2S. The value is a sum of values (powers of two), where each value in the sum represents a condition. The values that may be included in the sum and their meanings are: 0 Disable event reports 1 Send report when SYNC status has changed 2 Send report when RTS status has changed 4 Send report at Power On (Reset) 8 Report charging information at CLR.
OBJECT-TYPE    
  Integer32 0..15  

pktSwchSysEvRepPeriod2S 1.3.6.1.4.1.164.8.1.1.3.6
This specifies the time interval in minutes at which periodic reports are sent to the address specified in pktSwchSysEvRepAdd2S. A value of zero indicates that periodic reports are disabled.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchSysEvRepRetryCntS 1.3.6.1.4.1.164.8.1.1.3.7
Number of retries to send Event Reports to each port. Possible values: 0 - Disable retry mechanism 1-255 - Number of retries
OBJECT-TYPE    
  Integer32  

pktSwchSysEvRepRetryDelayS 1.3.6.1.4.1.164.8.1.1.3.8
Time interval between retries (in minutes). Valid values: 1-255
OBJECT-TYPE    
  Integer32  

pktSwchSysEvRepRetryOptionsS 1.3.6.1.4.1.164.8.1.1.3.9
Event report options. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 - No Options 1 - Alternate Mode: Port 1 reports are readdressed to Port 2 on failure. (Port 2 mask is not used). 2 - Condensed Format X - Any combination of the above values
OBJECT-TYPE    
  Integer32  

pktSwchSysEvRepA 1.3.6.1.4.1.164.8.1.1.4
OBJECT IDENTIFIER    

pktSwchSysEvRepAdd1A 1.3.6.1.4.1.164.8.1.1.4.1
This specifies the active X.25 address to which the reports selected by means of pktSwchSysEvRepMask1A and pktSwchSysEvRepPeriod1A will be sent.
OBJECT-TYPE    
  DisplayString  

pktSwchSysEvRepAdd2A 1.3.6.1.4.1.164.8.1.1.4.2
This specifies the active X.25 address to which the reports selected by means of pktSwchSysEvRepMask2A and pktSwchSysEvRepPeriod2A will be sent.
OBJECT-TYPE    
  DisplayString  

pktSwchSysEvRepMask1A 1.3.6.1.4.1.164.8.1.1.4.3
This specifies the active conditions on which reports are sent to the address specified in pktSwchSysEvRepAdd1A. The value is a sum of values (powers of two), where each value in the sum represents a condition. The values that may be included in the sum and their meanings are: 0 Disable event reports 1 Send report when SYNC status has changed 2 Send report when RTS status has changed 4 Send report at Power On (Reset) 8 Report charging information at CLR.
OBJECT-TYPE    
  Integer32 0..15  

pktSwchSysEvRepPeriod1A 1.3.6.1.4.1.164.8.1.1.4.4
This specifies the active time interval in minutes at which periodic reports are sent to the address specified in pktSwchSysEvRepAdd1A. A value of zero indicates that periodic reports are disabled.
OBJECT-TYPE    
  Integer32 1..255  

pktSwchSysEvRepMask2A 1.3.6.1.4.1.164.8.1.1.4.5
This specifies the active conditions on which reports are sent to the address specified in pktSwchSysEvRepAdd2A. The value is a sum of values (powers of two), where each value in the sum represents a condition. The values that may be included in the sum and their meanings are: 0 Disable event reports 1 Send report when SYNC status has changed 2 Send report when RTS status has changed 4 Send report at Power On (Reset) 8 Report charging information at CLR.
OBJECT-TYPE    
  Integer32 0..15  

pktSwchSysEvRepPeriod2A 1.3.6.1.4.1.164.8.1.1.4.6
This specifies the active time interval in minutes at which periodic reports are sent to the address specified in pktSwchSysEvRepAdd2A. A value of zero indicates that periodic reports are disabled.
OBJECT-TYPE    
  Integer32 1..255  

pktSwchSysEvRepRetryCntA 1.3.6.1.4.1.164.8.1.1.4.7
Number of retries to send Event Reports to each port. Possible values: 0 - Disable retry mechanism 1-255 - Number of retries
OBJECT-TYPE    
  Integer32  

pktSwchSysEvRepRetryDelayA 1.3.6.1.4.1.164.8.1.1.4.8
Time interval between retries (in minutes). Valid values: 1-255
OBJECT-TYPE    
  Integer32  

pktSwchSysEvRepRetryOptionsA 1.3.6.1.4.1.164.8.1.1.4.9
Event report options. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 - No Options 1 - Alternate Mode: Port 1 reports are readdressed to Port 2 on failure. (Port 2 mask is not used). 2 - Condensed Format X - Any combination of the above values
OBJECT-TYPE    
  Integer32  

pktSwchSysGen 1.3.6.1.4.1.164.8.1.1.5
OBJECT IDENTIFIER    

pktSwchSysDate 1.3.6.1.4.1.164.8.1.1.5.1
This is used to update the date on the device.
OBJECT-TYPE    
  DisplayString  

pktSwchSysTime 1.3.6.1.4.1.164.8.1.1.5.2
This is used to update the time on the device.
OBJECT-TYPE    
  DisplayString  

pktSwchSysAction 1.3.6.1.4.1.164.8.1.1.5.3
This is used to perform imperitive commands on the device. The reset command resets the device with the scratch values.
OBJECT-TYPE    
  INTEGER noOp(1), reset(2), resetStat(3), rearrangeNovram(4), setDefaultConfig(5)  

pktSwchSysRamSize 1.3.6.1.4.1.164.8.1.1.5.4
The RAM size on the device.
OBJECT-TYPE    
  Integer32  

pktSwchSysNovramSize 1.3.6.1.4.1.164.8.1.1.5.5
The NOVRAM size on the device.
OBJECT-TYPE    
  Integer32  

pktSwchSysNovramUtil 1.3.6.1.4.1.164.8.1.1.5.6
The NOVRAM utilization on the device.
OBJECT-TYPE    
  Integer32  

pktSwchSysFreeDataBuff 1.3.6.1.4.1.164.8.1.1.5.7
The free data buffers on the device.
OBJECT-TYPE    
  Integer32  

pktSwchSysMinDataBuffInPool 1.3.6.1.4.1.164.8.1.1.5.8
The minimum data buffers in the pool on the device.
OBJECT-TYPE    
  Integer32  

pktSwchSysProtocols 1.3.6.1.4.1.164.8.1.1.5.9
The protocols the device can support. The value is a sum of values (powers of two), where each value in the sum represents a protocol. The values that may be included in the sum and their meanings are: 1 X.25 2 Frame Relay 4 HDLC 8 SDLC 16 MPE 32 ASYNC 64 STM-4 128 STM-8 256 STM-16 512 STM-24 1024 BISYNC 2048 SLIP 4096 ETHERNET 8192 PPP 16384 ISDN XX - Any combination of the values specified above .
OBJECT-TYPE    
  Integer32  

pktSwchSysChannelProtocols 1.3.6.1.4.1.164.8.1.1.5.10
The protocols the device can support on the async channels. 1 ASYNC 2 SLIP 3 PPP
OBJECT-TYPE    
  Integer32  

pktSwchSysStatus 1.3.6.1.4.1.164.8.1.1.6
The status of the System data. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchRouting 1.3.6.1.4.1.164.8.1.2
OBJECT IDENTIFIER    

pktSwchRoutSTable 1.3.6.1.4.1.164.8.1.2.1
The Scratch Routing Table defines the routes for incoming and outgoing data on the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchRoutSEntry

pktSwchRoutSEntry 1.3.6.1.4.1.164.8.1.2.1.1
Defines the contents of each line in the Scratch Routing Table.
OBJECT-TYPE    
  PktSwchRoutSEntry  

pktSwchRoutIdS 1.3.6.1.4.1.164.8.1.2.1.1.1
Index of the pktSwchRoutSTable.
OBJECT-TYPE    
  Integer32 1..2000  

pktSwchRoutAddressS 1.3.6.1.4.1.164.8.1.2.1.1.2
The address to which the entry applies. The use of the octet string syntax allows the use of the letter x as a wild card in the addresses.
OBJECT-TYPE    
  DisplayString  

pktSwchRoutDestLink1S 1.3.6.1.4.1.164.8.1.2.1.1.3
First destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)
OBJECT-TYPE    
  DisplayString  

pktSwchRoutDestLink2S 1.3.6.1.4.1.164.8.1.2.1.1.4
Second destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)
OBJECT-TYPE    
  DisplayString  

pktSwchRoutDestLink3S 1.3.6.1.4.1.164.8.1.2.1.1.5
Third destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)
OBJECT-TYPE    
  DisplayString  

pktSwchRoutLinkPrio1S 1.3.6.1.4.1.164.8.1.2.1.1.6
A priority of the associated destination of link 1.
OBJECT-TYPE    
  Integer32  

pktSwchRoutLinkPrio2S 1.3.6.1.4.1.164.8.1.2.1.1.7
A priority of the associated destination of link 2.
OBJECT-TYPE    
  Integer32  

pktSwchRoutLinkPrio3S 1.3.6.1.4.1.164.8.1.2.1.1.8
A priority of the associated destination of link 3.
OBJECT-TYPE    
  Integer32  

pktSwchRoutSearchStatusS 1.3.6.1.4.1.164.8.1.2.1.1.9
off - The device stops searching for a matching address. on - The device continues searching for a matching address in the links of the next entry.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

pktSwchRoutStatusS 1.3.6.1.4.1.164.8.1.2.1.1.10
The status of this routing table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchRoutATable 1.3.6.1.4.1.164.8.1.2.2
The Active Routing Table defines the active routes for incoming and outgoing data on the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchRoutAEntry

pktSwchRoutAEntry 1.3.6.1.4.1.164.8.1.2.2.1
Defines the contents of each line in the Active Routing Table.
OBJECT-TYPE    
  PktSwchRoutAEntry  

pktSwchRoutIdA 1.3.6.1.4.1.164.8.1.2.2.1.1
Index of the pktSwchRoutATable.
OBJECT-TYPE    
  Integer32 1..2000  

pktSwchRoutAddressA 1.3.6.1.4.1.164.8.1.2.2.1.2
The address to which the entry applies. The use of the octet string syntax allows the use of the letter x as a wild card in the addresses.
OBJECT-TYPE    
  DisplayString  

pktSwchRoutDestLink1A 1.3.6.1.4.1.164.8.1.2.2.1.3
First destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)
OBJECT-TYPE    
  DisplayString  

pktSwchRoutDestLink2A 1.3.6.1.4.1.164.8.1.2.2.1.4
Second destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)
OBJECT-TYPE    
  DisplayString  

pktSwchRoutDestLink3A 1.3.6.1.4.1.164.8.1.2.2.1.5
Third destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)
OBJECT-TYPE    
  DisplayString  

pktSwchRoutLinkPrio1A 1.3.6.1.4.1.164.8.1.2.2.1.6
A priority of the associated destination of link 1.
OBJECT-TYPE    
  Integer32  

pktSwchRoutLinkPrio2A 1.3.6.1.4.1.164.8.1.2.2.1.7
A priority of the associated destination of link 2.
OBJECT-TYPE    
  Integer32  

pktSwchRoutLinkPrio3A 1.3.6.1.4.1.164.8.1.2.2.1.8
A priority of the associated destination of link 3.
OBJECT-TYPE    
  Integer32  

pktSwchRoutSearchStatusA 1.3.6.1.4.1.164.8.1.2.2.1.9
off - The device stops searching for a matching address. on - The device continues searching for a matching address in the links of the next entry.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

pktSwchPvcSTable 1.3.6.1.4.1.164.8.1.2.3
The Scratch Network PVC Table defines the network PVCs.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchPvcSEntry

pktSwchPvcSEntry 1.3.6.1.4.1.164.8.1.2.3.1
Defines the contents of each line in the Scratch Network PVC table.
OBJECT-TYPE    
  PktSwchPvcSEntry  

pktSwchPvcNumS 1.3.6.1.4.1.164.8.1.2.3.1.1
The PVC number corresponding to this entry.
OBJECT-TYPE    
  Integer32 1..200  


pktSwchPvcSrcLcnS 1.3.6.1.4.1.164.8.1.2.3.1.3
Network pvc: The number of the logical channel (0-255) that will be used as the source logical channel to create a connection by means of the PVC. Local pvc: For asynchronous channel to X.25 PVC, Any valid Async Channel number. For encapsulation of transparent HDLC over X25 PVC, valid Channel numbers are: HxM - for the main PVC. HxB - for the backup PVC. x is a valid HDLC link number. For encapsulation of Multi Point Encapsulator (MPE) over X25 PVC, valid channel numbers are: Nx - where x is a valid MPE link number. For encapsulation of IP Over X.25 PVC, Enter IP.
OBJECT-TYPE    
  DisplayString  


pktSwchPvcDstLcnS 1.3.6.1.4.1.164.8.1.2.3.1.5
The number of the logical channel for the destination link.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchPvcStatusS 1.3.6.1.4.1.164.8.1.2.3.1.6
The status of this Network PVC table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchPvcATable 1.3.6.1.4.1.164.8.1.2.4
The Active Network PVC Table defines the active network PVCs.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchPvcAEntry

pktSwchPvcAEntry 1.3.6.1.4.1.164.8.1.2.4.1
Defines the contents of each line in the Active Network PVC table.
OBJECT-TYPE    
  PktSwchPvcAEntry  

pktSwchPvcNumA 1.3.6.1.4.1.164.8.1.2.4.1.1
The PVC number corresponding to this entry.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchPvcSrcLinkA 1.3.6.1.4.1.164.8.1.2.4.1.2
The number of the link (1 through 6 for SPS-6 and 1 through 12 for SPS-12) that is used as a source link to create a connection by means of the PVC. 0 means that the PVC will not be active, 100 means that this pvc is Local.
OBJECT-TYPE    
  Integer32 0..100  

pktSwchPvcSrcLcnA 1.3.6.1.4.1.164.8.1.2.4.1.3
Network pvc: The number of the logical channel (0-255) that will be used as the source logical channel to create a connection by means of the PVC. Local pvc: For asynchronous channel to X.25 PVC, Any valid Async Channel number. For encapsulation of transparent HDLC over X25 PVC, valid Channel numbers are: HxM - for the main PVC. HxB - for the backup PVC. x is a valid HDLC link number. For encapsulation of Multi Point Encapsulator (MPE) over X25 PVC, valid channel numbers are: Nx - where x is a valid MPE link number. For encapsulation of IP Over X.25 PVC, Enter IP.
OBJECT-TYPE    
  DisplayString  

pktSwchPvcDstLinkA 1.3.6.1.4.1.164.8.1.2.4.1.4
The number of the destination link that is used. 0 means that the PVC will not be active.
OBJECT-TYPE    
  Integer32 0..12  

pktSwchPvcDstLcnA 1.3.6.1.4.1.164.8.1.2.4.1.5
The number of the logical channel for the destination link.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchNui 1.3.6.1.4.1.164.8.1.3
OBJECT IDENTIFIER    

pktSwchNuiSTable 1.3.6.1.4.1.164.8.1.3.1
The NUI Table defines the NUIs that can be used by the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchNuiSEntry

pktSwchNuiSEntry 1.3.6.1.4.1.164.8.1.3.1.1
Defines the contents of each line in the NUI Table.
OBJECT-TYPE    
  PktSwchNuiSEntry  

pktSwchNuiIndexS 1.3.6.1.4.1.164.8.1.3.1.1.1
The index of this entry.
OBJECT-TYPE    
  Integer32  

pktSwchNuiGroupIdS 1.3.6.1.4.1.164.8.1.3.1.1.2
The group Id for this NUI entry.
OBJECT-TYPE    
  Integer32  

pktSwchNuiInPasswdS 1.3.6.1.4.1.164.8.1.3.1.1.3
The password for the incoming call. 15 chars.
OBJECT-TYPE    
  DisplayString  

pktSwchNuiOutPasswdPointerS 1.3.6.1.4.1.164.8.1.3.1.1.4
A pointer to the password in the OutPasswdTable for an outgoing call.
OBJECT-TYPE    
  Integer32  

pktSwchNuiInAddrS 1.3.6.1.4.1.164.8.1.3.1.1.5
The addresss for the incoming call. 15 digits.
OBJECT-TYPE    
  DisplayString  

pktSwchNuiOutAddrPointerS 1.3.6.1.4.1.164.8.1.3.1.1.6
A pointer to the address in the OutAddrTable for an outgoing call.
OBJECT-TYPE    
  Integer32  

pktSwchNuiStatusS 1.3.6.1.4.1.164.8.1.3.1.1.7
The status of this NUI table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchNuiATable 1.3.6.1.4.1.164.8.1.3.2
The NUI Table defines the NUIs that can be used by the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchNuiAEntry

pktSwchNuiAEntry 1.3.6.1.4.1.164.8.1.3.2.1
Defines the contents of each line in the NUI Table.
OBJECT-TYPE    
  PktSwchNuiAEntry  

pktSwchNuiIndexA 1.3.6.1.4.1.164.8.1.3.2.1.1
The index of this entry.
OBJECT-TYPE    
  Integer32  

pktSwchNuiGroupIdA 1.3.6.1.4.1.164.8.1.3.2.1.2
The group Id for this NUI entry.
OBJECT-TYPE    
  Integer32  

pktSwchNuiInPasswdA 1.3.6.1.4.1.164.8.1.3.2.1.3
The password for the incoming call. 15 chars.
OBJECT-TYPE    
  DisplayString  

pktSwchNuiOutPasswdPointerA 1.3.6.1.4.1.164.8.1.3.2.1.4
A pointer to the password in the OutPasswdTable for an outgoing call.
OBJECT-TYPE    
  Integer32  

pktSwchNuiInAddrA 1.3.6.1.4.1.164.8.1.3.2.1.5
The addresss for the incoming call. 15 digits.
OBJECT-TYPE    
  DisplayString  

pktSwchNuiOutAddrPointerA 1.3.6.1.4.1.164.8.1.3.2.1.6
A pointer to the address in the OutAddrTable for an outgoing call.
OBJECT-TYPE    
  Integer32  

pktSwchNuiStatusA 1.3.6.1.4.1.164.8.1.3.2.1.7
The status of this NUI table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchNuiOutPasswdSTable 1.3.6.1.4.1.164.8.1.3.3
The table defines the passwords that can be used by the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchNuiOutPasswdSEntry

pktSwchNuiOutPasswdSEntry 1.3.6.1.4.1.164.8.1.3.3.1
Defines the contents of each line in OutPasswd Table.
OBJECT-TYPE    
  PktSwchNuiOutPasswdSEntry  

pktSwchNuiOutPasswdIndexS 1.3.6.1.4.1.164.8.1.3.3.1.1
The index of this entry.
OBJECT-TYPE    
  Integer32  

pktSwchNuiOutPasswdValueS 1.3.6.1.4.1.164.8.1.3.3.1.2
The password of this entry. 15 chars.
OBJECT-TYPE    
  DisplayString  

pktSwchNuiOutPasswdStatusS 1.3.6.1.4.1.164.8.1.3.3.1.3
The status of this NuiOutPasswd table entry.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchNuiOutPasswdATable 1.3.6.1.4.1.164.8.1.3.4
The table defines the passwords that can be used by the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchNuiOutPasswdAEntry

pktSwchNuiOutPasswdAEntry 1.3.6.1.4.1.164.8.1.3.4.1
Defines the contents of each line in OutPasswd Table.
OBJECT-TYPE    
  PktSwchNuiOutPasswdAEntry  

pktSwchNuiOutPasswdIndexA 1.3.6.1.4.1.164.8.1.3.4.1.1
The index of this entry.
OBJECT-TYPE    
  Integer32  

pktSwchNuiOutPasswdValueA 1.3.6.1.4.1.164.8.1.3.4.1.2
The password of this entry. 15 chars.
OBJECT-TYPE    
  DisplayString  

pktSwchNuiOutPasswdStatusA 1.3.6.1.4.1.164.8.1.3.4.1.3
The status of this NuiOutPasswd table entry.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchNuiOutAddrSTable 1.3.6.1.4.1.164.8.1.3.5
The table defines the Addresses that can be used by the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchNuiOutAddrSEntry

pktSwchNuiOutAddrSEntry 1.3.6.1.4.1.164.8.1.3.5.1
Defines the contents of each line in OutAddr Table.
OBJECT-TYPE    
  PktSwchNuiOutAddrSEntry  

pktSwchNuiOutAddrIndexS 1.3.6.1.4.1.164.8.1.3.5.1.1
The index of this entry.
OBJECT-TYPE    
  Integer32  

pktSwchNuiOutAddrValueS 1.3.6.1.4.1.164.8.1.3.5.1.2
The address of this entry. 15 digits.
OBJECT-TYPE    
  DisplayString  

pktSwchNuiOutAddrStatusS 1.3.6.1.4.1.164.8.1.3.5.1.3
The status of this NuiOutAddr table entry.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchNuiOutAddrATable 1.3.6.1.4.1.164.8.1.3.6
The table defines the Addresses that can be used by the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchNuiOutAddrAEntry

pktSwchNuiOutAddrAEntry 1.3.6.1.4.1.164.8.1.3.6.1
Defines the contents of each line in OutAddr Table.
OBJECT-TYPE    
  PktSwchNuiOutAddrAEntry  

pktSwchNuiOutAddrIndexA 1.3.6.1.4.1.164.8.1.3.6.1.1
The index of this entry.
OBJECT-TYPE    
  Integer32  

pktSwchNuiOutAddrValueA 1.3.6.1.4.1.164.8.1.3.6.1.2
The address of this entry. 15 digits.
OBJECT-TYPE    
  DisplayString  

pktSwchNuiOutAddrStatusA 1.3.6.1.4.1.164.8.1.3.6.1.3
The status of this NuiOutAddr table entry.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchMng 1.3.6.1.4.1.164.8.1.4
OBJECT IDENTIFIER    

pktSwchMngX25TrapIpTable 1.3.6.1.4.1.164.8.1.4.1
This table indicates the destination address of the traps. Internally it will be limited to ten addresses.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchMngX25Entry

pktSwchMngX25Entry 1.3.6.1.4.1.164.8.1.4.1.1
An entry in table pktSwchMngX25TrapIpTable.
OBJECT-TYPE    
  PktSwchMngX25Entry  

pktSwchMngID 1.3.6.1.4.1.164.8.1.4.1.1.1
This value indicates an index of a specific IP address
OBJECT-TYPE    
  Integer32  

pktSwchMngIP 1.3.6.1.4.1.164.8.1.4.1.1.2
This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry.
OBJECT-TYPE    
  IpAddress  

pktSwchMngPhyAddr 1.3.6.1.4.1.164.8.1.4.1.1.3
This value indicates the physical destination address of the traps.
OBJECT-TYPE    
  DisplayString  

pktSwchTrapEnable 1.3.6.1.4.1.164.8.1.4.1.1.4
This value indicates which traps should be sent. The value is a sum of values (powers of two), where each value in the sum represents a trap that should be reported to the Management Station. The values that may be included in the sum and their meanings are: 0 No traps would be reported. 1 Link Down 2 Link Up 4 rtsChange 8 resetX25 16 restartX25 32 frDLCIStatusChange 64 coldStart 128 linkProtocolChanged 256 enrollmentPS 512 ledStatusChange
OBJECT-TYPE    
  Integer32  

pktSwchEncapsulationMode 1.3.6.1.4.1.164.8.1.4.1.1.5
Format type for IP over X25
OBJECT-TYPE    
  INTEGER ipPid(1), snapPid(2)  

pktSwchXid 1.3.6.1.4.1.164.8.1.5
OBJECT IDENTIFIER    

pktSwchXidSTable 1.3.6.1.4.1.164.8.1.5.1
The Exchange Id table contains a list of 13 incoming pairs of allowed dial-up phone numbers and passwords. Also included is one pair of outgoing phone number and password (InternalIndex=14).
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchXidSEntry

pktSwchXidSEntry 1.3.6.1.4.1.164.8.1.5.1.1
An entry in table pktSwchXidSTable.
OBJECT-TYPE    
  PktSwchXidSEntry  

pktSwchXidIndexS 1.3.6.1.4.1.164.8.1.5.1.1.1
This Index of the XID table.
OBJECT-TYPE    
  Integer32  

pktSwchXidInternalIndexS 1.3.6.1.4.1.164.8.1.5.1.1.2
An internal index for each XidIndex of the table. The first 13 entries refer to Incoming calls. The 14th entry refers to an Outgoing call.
OBJECT-TYPE    
  Integer32  

pktSwchXidPasswdS 1.3.6.1.4.1.164.8.1.5.1.1.3
Password of size 16 chars.
OBJECT-TYPE    
  DisplayString  

pktSwchXidPhoneS 1.3.6.1.4.1.164.8.1.5.1.1.4
Phone number of size 16 digits.
OBJECT-TYPE    
  DisplayString  

pktSwchXidStatusS 1.3.6.1.4.1.164.8.1.5.1.1.5
The status of the XID table entry. The status applies to the XidIndex, i.e., setting the staus to invalid results in the removal of all the InternalIndex entries (1..14) belonging to the relevant XidIndex.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchXidATable 1.3.6.1.4.1.164.8.1.5.2
The Exchange Id table contains a list of 13 incoming pairs of allowed dial-up phone numbers and passwords. Also included is one pair of outgoing phone number and password (InternalIndex=14).
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchXidAEntry

pktSwchXidAEntry 1.3.6.1.4.1.164.8.1.5.2.1
An entry in table pktSwchXidATable.
OBJECT-TYPE    
  PktSwchXidAEntry  

pktSwchXidIndexA 1.3.6.1.4.1.164.8.1.5.2.1.1
This Index of the XID table.
OBJECT-TYPE    
  Integer32  

pktSwchXidInternalIndexA 1.3.6.1.4.1.164.8.1.5.2.1.2
An internal index for each XidIndex of the table. The first 13 entries refer to Incoming calls. The 14th entry refers to an Outgoing call.
OBJECT-TYPE    
  Integer32  

pktSwchXidPasswdA 1.3.6.1.4.1.164.8.1.5.2.1.3
Password of size 16 chars.
OBJECT-TYPE    
  DisplayString  

pktSwchXidPhoneA 1.3.6.1.4.1.164.8.1.5.2.1.4
Phone number of size 16 digits.
OBJECT-TYPE    
  DisplayString  

pktSwchXidStatusA 1.3.6.1.4.1.164.8.1.5.2.1.5
The status of the XID table entry. The status applies to the XidIndex, i.e., setting the staus to invalid results in the removal of all the InternalIndex entries (1..14) belonging to the relevant XidIndex.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchIpRouting 1.3.6.1.4.1.164.8.1.6
OBJECT IDENTIFIER    

pktSwchIpRoutSTable 1.3.6.1.4.1.164.8.1.6.1
The Scratch Routing Table defines the routes for incoming and outgoing ip datagrams on the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchIpRoutSEntry

pktSwchIpRoutSEntry 1.3.6.1.4.1.164.8.1.6.1.1
Defines the contents of each line in the Scratch IP Routing Table.
OBJECT-TYPE    
  PktSwchIpRoutSEntry  

pktSwchIpRoutIdS 1.3.6.1.4.1.164.8.1.6.1.1.1
Index of the pktSwchIpRoutSTable.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchIpRoutIpAddressS 1.3.6.1.4.1.164.8.1.6.1.1.2
The IP address to which the entry applies. A string of the format: X.X.X.X where every X is a number in the range 0-255.
OBJECT-TYPE    
  IpAddress  

pktSwchIpRoutIpMaskS 1.3.6.1.4.1.164.8.1.6.1.1.3
The IP mask to which the entry applies. A string of the format: X.X.X.X where every X is a number in the range 0-255.
OBJECT-TYPE    
  IpAddress  

pktSwchIpRoutDestProtocolS 1.3.6.1.4.1.164.8.1.6.1.1.4
Destination protocol for the associated address. None(255) when not used
OBJECT-TYPE    
  INTEGER slip(1), x25SVC(2), x25PVC(3), frameRelay(4), hdlc(5), ethernet(7), ppp(8), none(255)  

pktSwchIpRoutDestinationS 1.3.6.1.4.1.164.8.1.6.1.1.5
Destination for the associated address. Possible values: Default : Not Used. X.25 PVC: Port:LCN or a pre defined PVC number X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number Frame Relay: Port:DLCI HDLC: 'H' followed by the HDLC Port Number SLIP: 'S' followed by the SLIP Channel Number Ethernet: 'E' followed by the Ethernet Port Number PPP: 'P' followed by the PPP Port Number.
OBJECT-TYPE    
  DisplayString  

pktSwchIpRoutInactivityS 1.3.6.1.4.1.164.8.1.6.1.1.6
Inactivity time in steps of 50 mili seconds for X25 SVC protocol only. Range: 0..255. Default: 2.
OBJECT-TYPE    
  Integer32  

pktSwchIpRoutStatusS 1.3.6.1.4.1.164.8.1.6.1.1.7
The status of this routing table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchIpRoutMetricS 1.3.6.1.4.1.164.8.1.6.1.1.8
No. of hops for this route. The default value is 1. Legal values: 1 to the max no. of hops this device will support. The max no. is defined by pktSwchIpGlobalMaxHopCount.
OBJECT-TYPE    
  Integer32  

pktSwchIpRoutNextHopS 1.3.6.1.4.1.164.8.1.6.1.1.9
IP address of the next hop. A string of the format: X.X.X.X where every X is a number in the range 0-255.
OBJECT-TYPE    
  IpAddress  

pktSwchIpRoutInterfaceIdS 1.3.6.1.4.1.164.8.1.6.1.1.10
ID of the logical IP interface in the pktSwchIpInterface table. The IP routing module will route the IP frame according to this interface ID. Legal values: 1 to 200 and 65535. 1-200 : ID of interface. 65535 : No IP interface ID. Default value: 65535.
OBJECT-TYPE    
  Integer32  

pktSwchIpRoutATable 1.3.6.1.4.1.164.8.1.6.2
The Active Routing Table defines the active routes for incoming and outgoing ip datagrams on the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchIpRoutAEntry

pktSwchIpRoutAEntry 1.3.6.1.4.1.164.8.1.6.2.1
Defines the contents of each line in the Active IP Routing Table.
OBJECT-TYPE    
  PktSwchIpRoutAEntry  

pktSwchIpRoutIdA 1.3.6.1.4.1.164.8.1.6.2.1.1
Index of the IP pktSwchIpRoutATable.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchIpRoutIpAddressA 1.3.6.1.4.1.164.8.1.6.2.1.2
The IP address to which the entry applies. A string of the format: X.X.X.X where every X is a number in the range 0-255.
OBJECT-TYPE    
  IpAddress  

pktSwchIpRoutIpMaskA 1.3.6.1.4.1.164.8.1.6.2.1.3
The IP mask to which the entry applies. A string of the format: X.X.X.X where every X is a number in the range 0-255.
OBJECT-TYPE    
  IpAddress  

pktSwchIpRoutDestProtocolA 1.3.6.1.4.1.164.8.1.6.2.1.4
Destination protocol for the associated address. None(255) when not used.
OBJECT-TYPE    
  INTEGER slip(1), x25SVC(2), x25PVC(3), frameRelay(4), hdlc(5), snmpAgent(6), ethernet(7), ppp(8), none(255)  

pktSwchIpRoutDestinationA 1.3.6.1.4.1.164.8.1.6.2.1.5
Destination for the associated address. Possible values: Default : Not Used. X.25 PVC: Port:LCN or a pre defined PVC number X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number Frame Relay: Port:DLCI HDLC: 'H' followed by the HDLC Port Number SLIP: 'S' followed by the SLIP Channel Number Ethernet: 'E' followed by the Ethernet Port Number PPP: 'P' followed by the PPP Port Number.
OBJECT-TYPE    
  DisplayString  

pktSwchIpRoutInactivityA 1.3.6.1.4.1.164.8.1.6.2.1.6
Inactivity time in steps of 50 mili seconds for X25 SVC protocol only. Range: 0..255. Default: 2.
OBJECT-TYPE    
  Integer32  

pktSwchIpRoutBuffsInA 1.3.6.1.4.1.164.8.1.6.2.1.7
The number of packets in the Input buffer link list, received but not routed yet.
OBJECT-TYPE    
  Counter32  

pktSwchIpRoutBuffsOutA 1.3.6.1.4.1.164.8.1.6.2.1.8
The number of packets in the Output buffer link list, routed but not sent yet.
OBJECT-TYPE    
  Counter32  

pktSwchIpRoutFCA 1.3.6.1.4.1.164.8.1.6.2.1.9
This is the flow control status of this ip routing entry\connection
OBJECT-TYPE    
  INTEGER discard(1), flowControl(2), normal(3)  

pktSwchIpRoutMetricA 1.3.6.1.4.1.164.8.1.6.2.1.10
No. of hops for this route. The default value is 1. Legal values: 1 to the max no. of hops this device will support. The max no. is defined by pktSwchIpGlobalMaxHopCount.
OBJECT-TYPE    
  Integer32  

pktSwchIpRoutNextHopA 1.3.6.1.4.1.164.8.1.6.2.1.11
IP address of the next hop. A string of the format: X.X.X.X where every X is a number in the range 0-255.
OBJECT-TYPE    
  IpAddress  

pktSwchIpRoutInterfaceIdA 1.3.6.1.4.1.164.8.1.6.2.1.12
ID of the logical IP interface in the pktSwchIpInterface table. The IP routing module will route the IP frame according to this interface ID. Legal values: 1 to 200 and 65535. 1-200 : ID of interface. 65535 : No IP interface ID. Default value: 65535.
OBJECT-TYPE    
  Integer32  

pktSwchPriority 1.3.6.1.4.1.164.8.1.7
OBJECT IDENTIFIER    

pktSwchTxPriorityStatus 1.3.6.1.4.1.164.8.1.7.1
The status of the Priorities table. Used for saving the Priority parameters.
OBJECT-TYPE    
  INTEGER valid(1), underCreation(3)  

pktSwchTxPriorityTable 1.3.6.1.4.1.164.8.1.7.2
The Tx Priorities table.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchTxPriorityEntry

pktSwchTxPriorityEntry 1.3.6.1.4.1.164.8.1.7.2.1
The Tx Priority Entry defines the max delay time and max queue length for each Priority level.
OBJECT-TYPE    
  PktSwchTxPriorityEntry  

pktSwchTxPriorityLevel 1.3.6.1.4.1.164.8.1.7.2.1.1
Level of an entry in the Tx Priority Table. At present, the PS supports 4 priority levels. Default level: 1
OBJECT-TYPE    
  Integer32 1..4  

pktSwchTxPriorityMaxDelayTime 1.3.6.1.4.1.164.8.1.7.2.1.2
Max delay time in Tx queue (in 100 msec intervals). Each frame will wait no more than the Max delay time until it is handled. 0 means that the delay is Unlimited. Default value: 0
OBJECT-TYPE    
  Integer32 0..60000  

pktSwchTxPriorityMaxQueueLen 1.3.6.1.4.1.164.8.1.7.2.1.3
Max allowed length of the Tx queue. Frames will be discarded if the length is exceeded. 0 means that the queue is of Unlimited length. Default value: 0
OBJECT-TYPE    
  Integer32 0..65535  

pktSwchAsync 1.3.6.1.4.1.164.8.2
OBJECT IDENTIFIER    

pktSwchProfile 1.3.6.1.4.1.164.8.2.1
OBJECT IDENTIFIER    

pktSwchProfileSTable 1.3.6.1.4.1.164.8.2.1.1
The Profile Table S defines the Scratch profiles that the PS can use to configure a channel.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchProfileSEntry

pktSwchProfileSEntry 1.3.6.1.4.1.164.8.2.1.1.1
Defines the contents of each line in the Profile Table S.
OBJECT-TYPE    
  PktSwchProfileSEntry  

pktSwchProfileNumberS 1.3.6.1.4.1.164.8.2.1.1.1.1
The number by which a profile is identified. This is also used as the index for the profile table. The maximum profile number is 200.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchProfileRecallCharS 1.3.6.1.4.1.164.8.2.1.1.1.2
The character specified by this entry is used to escape from the data transfer mode and enter the PAD command mode. The integer values have the following meanings: (0) PAD recall is not possible (1) The PAD recall character is DLE (2) to (126) The PAD recall character is specified by the user by entering its ASCII code.
OBJECT-TYPE    
  Integer32 0..126  

pktSwchProfileEchoS 1.3.6.1.4.1.164.8.2.1.1.1.3
This determines if an echo of the input characters is retured to the DTE. The options are either 'echo enabled' or 'no echo'.
OBJECT-TYPE    
  INTEGER echEn(1), noEch(2)  

pktSwchProfileDataForwCharS 1.3.6.1.4.1.164.8.2.1.1.1.4
The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) used as a data forwarding character. The data forwarding characters are used to instruct the PAD to complete the assembly of and to forward a packet containing the data accumulated up to the reception of such a character. The values that may be included in the sum and their meanings are: 0 Data forwarding characters are not used 1 Alpha-numeric characters (A to Z, a to z, 0 to 9, inclusive) 2 Character CR 4 Characters ESC, BEL, ENQ, ACK 8 Characters DEL, CAN, DC2 16 Characters EOT, ETX 32 Characters HT, LF, VT, FF 64 All the other characters in colums 0 and 1 of IA5 and not listed above.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileIdleTimerS 1.3.6.1.4.1.164.8.2.1.1.1.5
Packets will be forwarded when the idle timer expires. The idle time interval is specified as a multiple of 50 milliseconds. The multiple is given by the parameter value. For example, a value of 60 sets an interval of 3 seconds. If the parameter value is 0, no forwarding occurs after the idle condition.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileDevFlowContS 1.3.6.1.4.1.164.8.2.1.1.1.6
This parameter determines whether or not the PAD uses software flow control for the attached device. The options are either (1) PAD uses flow control during data transfer mode, (2) PAD uses flow control both in the data transfer mode and in the command mode, or (255) PAD does not use flow control.
OBJECT-TYPE    
  INTEGER trans(1), transAndCom(2), noFlow(255)  

pktSwchProfileServSigS 1.3.6.1.4.1.164.8.2.1.1.1.7
This parameter is used to instruct the PAD whether to transfer PAD service signals and the PAD prompt to the local DTE in standard format. The options are (1) PAD service signals are transmitted to the DTE using the standard format, (4) The PAD prompt is transmitted using the standard format, (5) PAD service signals and the PAD prompt are transmitted in the standard format, or (255) No PAD service signals are transmitted to the DTE.
OBJECT-TYPE    
  INTEGER serv(1), prompt(4), servAndPrompt(5), noSig(255)  

pktSwchProfileBreakS 1.3.6.1.4.1.164.8.2.1.1.1.8
The value is a sum of values (powers of two), where each value in the sum represents a PAD operation on receipt of the break signal from the DTE. The values that may be included in the sum and their meanings are: 0 Nothing 1 Send interrupt packet to network 2 Send RESET packet to network 4 Send and 'indication of break' message 8 Escape from data transfer mode 16 Discard output data waiting to be sent to the DTE .
OBJECT-TYPE    
  Integer32 0..31  

pktSwchProfileDiscOutS 1.3.6.1.4.1.164.8.2.1.1.1.9
This parameter instructs the PAD whether to forward the user sequences included in data packets to the local DTE or discard them. The options are (1) discard output or (2) normal data delivery. If the value of radSPSProfileBreak is 21, the value of pktSwchProfileDiscOut is automatically set to (1) when a break signal is received.
OBJECT-TYPE    
  INTEGER discOut(1), normal(2)  

pktSwchProfileCRPaddingS 1.3.6.1.4.1.164.8.2.1.1.1.10
This parameter specifies the number of padding characters to be added after a carriage return character is transmitted to the local DTE.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileLineFoldS 1.3.6.1.4.1.164.8.2.1.1.1.11
This parameter specifies the maximum number of characters to be inserted before the format effector. If the value is zero, there is no insertion of a format effector (line folding).
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileSpeedS 1.3.6.1.4.1.164.8.2.1.1.1.12
This parameter determines the rate of data transmission to and from the DTE.
OBJECT-TYPE    
  INTEGER s110bps(1), s300bps(2), s1200bps(3), s600bps(4), s75bps(5), s150bps(6), s2400bps(12), s4800bps(13), s9600bps(14), s19200bps(15), s38400bps(19), s57600bps(20), s115200bps(21)  

pktSwchProfilePadFlowContS 1.3.6.1.4.1.164.8.2.1.1.1.13
This determines whether or not the terminal can exercise flow control over the PAD. The options are either 'device can exercise flow control' or 'device cannot exercise flow control.
OBJECT-TYPE    
  INTEGER flowCont(1), noFlowCont(2)  

pktSwchProfileLineFeedInsertS 1.3.6.1.4.1.164.8.2.1.1.1.14
This parameter indicates when there is a line feed insertion after CR. The options are (1) Insert line feed after transmission of CR to the DTE, (2) Insert line feed after receipt of CR from the DTE, (4) Insert line feed after echoing a CR character to the DTE, (5) Combination of (1) and (4), (6) Insert line feed after any CR to the DTE (combination of (2) and (4)), (7) Combination of (1), (2), and (4), or (255) No line feed insertion.
OBJECT-TYPE    
  INTEGER afterCR(1), recCR(2), echoCR(4), onePlusFour(5), twoPlusFour(6), oneTwoFour(7), noFeed(255)  

pktSwchProfileLineFeedPadS 1.3.6.1.4.1.164.8.2.1.1.1.15
This parameter specifies the number of padding characters to be added after a line feed.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileEditingS 1.3.6.1.4.1.164.8.2.1.1.1.16
This parameter specifies the editing capabilities available in the data transfer mode. Editing is always possible when the PAD is in the command mode. The options are (1) Command editing in the data trasfer mode is enabled or (2) No command editing in the data transfer mode.
OBJECT-TYPE    
  INTEGER edit(1), noEdit(2)  

pktSwchProfileCharDelS 1.3.6.1.4.1.164.8.2.1.1.1.17
This parameter specifies the character delete, which is one character from IA5. The default selection is 127 (character DEL).
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileLineDelS 1.3.6.1.4.1.164.8.2.1.1.1.18
This parameter specifies the line delete (last line stored in the edit buffer), which is one character from IA5. The default selection is 24 (character CAN).
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileLineDispS 1.3.6.1.4.1.164.8.2.1.1.1.19
This entry specifies the line display character, which is one character from IA5. The default selection is 18 (character DC2).
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileEditServSigS 1.3.6.1.4.1.164.8.2.1.1.1.20
This entry specifies the editing PAD service signals. The integer values have the following meanings: (0) No editing PAD service signals (1) Editing PAD service signals for printing terminals (2) Editing PAD service signals for display terminals (3) to (126) Editing PAD service signals using the desired character from IA5.
OBJECT-TYPE    
  Integer32 0..126  

pktSwchProfileEchomaskS 1.3.6.1.4.1.164.8.2.1.1.1.21
The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) included in the echo mask. The characters in the echo mask are not echoed to the DTE when PAD echo is enabled. The values that may be included in the sum and their meanings are: 0 No echo mask (all the characters are echoed) 1 No echo of character CR 2 No echo of character LF 4 No echo of characters VT, HT, FF 8 No echo of characters BEL, BS 16 No echo of characters ESC, ENQ 32 No echo of characters ACK, NAK, STX, SOH, EOT, ETB, ETX 64 No echo of the editing characters selected by radSPSProfileCharDel, radSPSProfileLineDel, and radSPSProfileLineDisp 128 No echo of the DEL character and of all the other characters in the range of ASCII 00 through 31 not mentioned above.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileParTreatS 1.3.6.1.4.1.164.8.2.1.1.1.22
This entry controls the generation of parity bits in the data sent to the local DTE and the checking of the parity bit when generated by the local DTE. The options are (1) parity checking is enabled, (2) parity generation is enabled, (3) parity checking and generation are enabled, or (255) no parity checking nor parity generation.
OBJECT-TYPE    
  INTEGER parCheck(1), parGen(2), checkAndGen(3), noPar(255)  

pktSwchProfilePageWaitS 1.3.6.1.4.1.164.8.2.1.1.1.23
This entry specifies the number of line feed characters counted by the PAD before the page wait condition is entered. If the value is zero, page wait is disabled.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileBitsPerCharS 1.3.6.1.4.1.164.8.2.1.1.1.24
The number of data bits per character supported by the PAD.
OBJECT-TYPE    
  Integer32 5..8  

pktSwchProfileDvParityS 1.3.6.1.4.1.164.8.2.1.1.1.25
This entry selects the type of parity to be checked and or generated by the PAD when radSPSProfileParTreat is a value other than 255. The options are (1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity.
OBJECT-TYPE    
  INTEGER space(1), mark(2), even(3), odd(4), none(255)  

pktSwchProfileStopBitsS 1.3.6.1.4.1.164.8.2.1.1.1.26
This entry indicates the number of stop bits per character supported by the PAD. The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits.
OBJECT-TYPE    
  INTEGER one(1), two(2), oneAndHalf(3)  

pktSwchProfileSpecFlowS 1.3.6.1.4.1.164.8.2.1.1.1.27
This entry is used to define additional flow control possiblilites. The options are either (1) Flow control by means of the terminal DTR line or (2) No special flow control.
OBJECT-TYPE    
  INTEGER spec(1), noSpec(2)  

pktSwchProfileCountFwdS 1.3.6.1.4.1.164.8.2.1.1.1.28
This entry can be used to instruct the PAD to complete the assembly of a packet and to forward it after the specifed number of characters has been received. If the value is zero, count forwarding is disabled.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileEscDelayS 1.3.6.1.4.1.164.8.2.1.1.1.29
This entry can be used to instruct the PAD whether to delay the forwarding of a data packet when an escape character is detected in the data stream and to determine the required delay. The packet forwarding is delayed until the specified number of characters is received after the escape character. A value of zero indicates no special handling( at the moment up to 10 chars are accepted).
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileCharBreakS 1.3.6.1.4.1.164.8.2.1.1.1.30
This entry specifies the decimal value of the character that will be interpreted as an additional break signal by the PAD. A value of zero indicates no break character.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileCharSuppressS 1.3.6.1.4.1.164.8.2.1.1.1.31
This entry specifies the decimal value of the character that will toggle echo suppression in the PAD. A value of zero indicates that echo suppression is only controlled by radSPSProfileEcho.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileCharSubsS 1.3.6.1.4.1.164.8.2.1.1.1.32
This entry specifies the decimal value of the character that will be echoed instead of the character received from the user's DTE. A zero value indicates that no character is echoed.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileFormFeedPadS 1.3.6.1.4.1.164.8.2.1.1.1.33
This entry specifies the number of padding (NUL) characters that will be automatically sent after the form feed character.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileInactivityS 1.3.6.1.4.1.164.8.2.1.1.1.34
This entry specifies the number of minutes after which the PAD will forward the accumulated data and clear the call. A zero value indicates no disconnection on inactivity.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileOptionsS 1.3.6.1.4.1.164.8.2.1.1.1.35
This entry defines several options to control the profile. The value is a sum of values (powers of two), where each value in the sum represents an option . The values that may be included in the sum and their meanings are: 0 No options 1 Remote set of local X.3 parameters through X.29 is disabled 2 Add sub address to call request 4 Don't use protocol ID in user data field. 8 SPRINT NUI format 16 More bit is set when the edit buffer is full 32 Extended error message 64 Discard connect extended service signal 128 enable connect by typing the address w/out a command
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileClrTimerS 1.3.6.1.4.1.164.8.2.1.1.1.36
This entry specifies the number of minutes after which a call is cleared. If the parameter value is 0, there is no disconnection timer.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileSubAddInCUDS 1.3.6.1.4.1.164.8.2.1.1.1.37
This entry defines the number of digits for the subaddress in CUD.
OBJECT-TYPE    
  Integer32 0..5  

pktSwchProfileStatusS 1.3.6.1.4.1.164.8.2.1.1.1.38
The status of this profile. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchProfileATable 1.3.6.1.4.1.164.8.2.1.2
The Profile Table defines the profiles that the PS can use to configure a channel.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchProfileAEntry

pktSwchProfileAEntry 1.3.6.1.4.1.164.8.2.1.2.1
Defines the contents of each line in the Profile Table.
OBJECT-TYPE    
  PktSwchProfileAEntry  

pktSwchProfileNumberA 1.3.6.1.4.1.164.8.2.1.2.1.1
The number by which a profile is identified. This is also used as the index for the profile table. The maximum profile number is 200.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchProfileRecallCharA 1.3.6.1.4.1.164.8.2.1.2.1.2
The character specified by this entry is used to escape from the data transfer mode and enter the PAD command mode. The integer values have the following meanings: (0) PAD recall is not possible (1) The PAD recall character is DLE (2) to (126) The PAD recall character is specified by the user by entering its ASCII code.
OBJECT-TYPE    
  Integer32 0..126  

pktSwchProfileEchoA 1.3.6.1.4.1.164.8.2.1.2.1.3
This determines if an echo of the input characters is retured to the DTE. The options are either 'echo enabled' or 'no echo'.
OBJECT-TYPE    
  INTEGER echEn(1), noEch(2)  

pktSwchProfileDataForwCharA 1.3.6.1.4.1.164.8.2.1.2.1.4
The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) used as a data forwarding character. The data forwarding characters are used to instruct the PAD to complete the assembly of and to forward a packet containing the data accumulated up to the reception of such a character. The values that may be included in the sum and their meanings are: 0 Data forwarding characters are not used 1 Alpha-numeric characters (A to Z, a to z, 0 to 9, inclusive) 2 Character CR 4 Characters ESC, BEL, ENQ, ACK 8 Characters DEL, CAN, DC2 16 Characters EOT, ETX 32 Characters HT, LF, VT, FF 64 All the other characters in colums 0 and 1 of IA5 and not listed above.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileIdleTimerA 1.3.6.1.4.1.164.8.2.1.2.1.5
Packets will be forwarded when the idle timer expires. The idle time interval is specified as a multiple of 50 milliseconds. The multiple is given by the parameter value. For example, a value of 60 sets an interval of 3 seconds. If the parameter value is 0, no forwarding occurs after the idle condition.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileDevFlowContA 1.3.6.1.4.1.164.8.2.1.2.1.6
This parameter determines whether or not the PAD uses software flow control for the attached device. The options are either (1) PAD uses flow control during data transfer mode, (2) PAD uses flow control both in the data transfer mode and in the command mode, or (255) PAD does not use flow control.
OBJECT-TYPE    
  INTEGER trans(1), transAndCom(2), noFlow(255)  

pktSwchProfileServSigA 1.3.6.1.4.1.164.8.2.1.2.1.7
This parameter is used to instruct the PAD whether to transfer PAD service signals and the PAD prompt to the local DTE in standard format. The options are (1) PAD service signals are transmitted to the DTE using the standard format, (4) The PAD prompt is transmitted using the standard format, (5) PAD service signals and the PAD prompt are transmitted in the standard format, or (255) No PAD service signals are transmitted to the DTE.
OBJECT-TYPE    
  INTEGER serv(1), prompt(4), servAndPrompt(5), noSig(255)  

pktSwchProfileBreakA 1.3.6.1.4.1.164.8.2.1.2.1.8
The value is a sum of values (powers of two), where each value in the sum represents a PAD operation on receipt of the break signal from the DTE. The values that may be included in the sum and their meanings are: 0 Nothing 1 Send interrupt packet to network 2 Send RESET packet to network 4 Send and 'indication of break' message 8 Escape from data transfer mode 16 Discard output data waiting to be sent to the DTE .
OBJECT-TYPE    
  Integer32 0..31  

pktSwchProfileDiscOutA 1.3.6.1.4.1.164.8.2.1.2.1.9
This parameter instructs the PAD whether to forward the user sequences included in data packets to the local DTE or discard them. The options are (1) discard output or (2) normal data delivery. If the value of radSPSProfileBreak is 21, the value of pktSwchProfileDiscOut is automatically set to (1) when a break signal is received.
OBJECT-TYPE    
  INTEGER discOut(1), normal(2)  

pktSwchProfileCRPaddingA 1.3.6.1.4.1.164.8.2.1.2.1.10
This parameter specifies the number of padding characters to be added after a carriage return character is transmitted to the local DTE.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileLineFoldA 1.3.6.1.4.1.164.8.2.1.2.1.11
This parameter specifies the maximum number of characters to be inserted before the format effector. If the value is zero, there is no insertion of a format effector (line folding).
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileSpeedA 1.3.6.1.4.1.164.8.2.1.2.1.12
This parameter determines the rate of data transmission to and from the DTE.
OBJECT-TYPE    
  INTEGER s110bps(1), s300bps(2), s1200bps(3), s600bps(4), s75bps(5), s150bps(6), s2400bps(12), s4800bps(13), s9600bps(14), s19200bps(15), s38400bps(19), s57600bps(20), s115200bps(21)  

pktSwchProfilePadFlowContA 1.3.6.1.4.1.164.8.2.1.2.1.13
This determines whether or not the terminal can exercise flow control over the PAD. The options are either 'device can exercise flow control' or 'device cannot exercise flow control.
OBJECT-TYPE    
  INTEGER flowCont(1), noFlowCont(2)  

pktSwchProfileLineFeedInsertA 1.3.6.1.4.1.164.8.2.1.2.1.14
This parameter indicates when there is a line feed insertion after CR. The options are (1) Insert line feed after transmission of CR to the DTE, (2) Insert line feed after receipt of CR from the DTE, (4) Insert line feed after echoing a CR character to the DTE, (5) Combination of (1) and (4), (6) Insert line feed after any CR to the DTE (combination of (2) and (4)), (7) Combination of (1), (2), and (4), or (255) No line feed insertion.
OBJECT-TYPE    
  INTEGER afterCR(1), recCR(2), echoCR(4), onePlusFour(5), twoPlusFour(6), oneTwoFour(7), noFeed(255)  

pktSwchProfileLineFeedPadA 1.3.6.1.4.1.164.8.2.1.2.1.15
This parameter specifies the number of padding characters to be added after a line feed.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileEditingA 1.3.6.1.4.1.164.8.2.1.2.1.16
This parameter specifies the editing capabilities available in the data transfer mode. Editing is always possible when the PAD is in the command mode. The options are (1) Command editing in the data trasfer mode is enabled or (2) No command editing in the data transfer mode.
OBJECT-TYPE    
  INTEGER edit(1), noEdit(2)  

pktSwchProfileCharDelA 1.3.6.1.4.1.164.8.2.1.2.1.17
This parameter specifies the character delete, which is one character from IA5. The default selection is 127 (character DEL).
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileLineDelA 1.3.6.1.4.1.164.8.2.1.2.1.18
This parameter specifies the line delete, which is one character from IA5. The default selection is 24 (character CAN).
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileLineDispA 1.3.6.1.4.1.164.8.2.1.2.1.19
This entry specifies the line display character, which is one character from IA5. The default selection is 18 (character DC2).
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileEditServSigA 1.3.6.1.4.1.164.8.2.1.2.1.20
This entry specifies the editing PAD service signals. The integer values have the following meanings: (0) No editing PAD service signals (1) Editing PAD service signals for printing terminals (2) Editing PAD service signals for display terminals (3) to (126) Editing PAD service signals using the desired character from IA5.
OBJECT-TYPE    
  Integer32 0..126  

pktSwchProfileEchomaskA 1.3.6.1.4.1.164.8.2.1.2.1.21
The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) included in the echo mask. The characters in the echo mask are not echoed to the DTE when PAD echo is enabled. The values that may be included in the sum and their meanings are: 0 No echo mask (all the characters are echoed) 1 No echo of character CR 2 No echo of character LF 4 No echo of characters VT, HT, FF 8 No echo of characters BEL, BS 16 No echo of characters ESC, ENQ 32 No echo of characters ACK, NAK, STX, SOH, EOT, ETB, ETX 64 No echo of the editing characters selected by radSPSProfileCharDel, radSPSProfileLineDel, and radSPSProfileLineDisp 128 No echo of the DEL character and of all the other characters in the range of ASCII 00 through 31 not mentioned above.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileParTreatA 1.3.6.1.4.1.164.8.2.1.2.1.22
This entry controls the generation of parity bits in the data sent to the local DTE and the checking of the parity bit when generated by the local DTE. The options are (1) parity checking is enabled, (2) parity generation is enabled, (3) parity checking and generation are enabled, or (255) no parity checking nor parity generation.
OBJECT-TYPE    
  INTEGER parCheck(1), parGen(2), checkAndGen(3), noPar(255)  

pktSwchProfilePageWaitA 1.3.6.1.4.1.164.8.2.1.2.1.23
This entry specifies the number of line feed characters counted by the PAD before the page wait condition is entered. If the value is zero, page wait is disabled.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileBitsPerCharA 1.3.6.1.4.1.164.8.2.1.2.1.24
The number of data bits per character supported by the PAD.
OBJECT-TYPE    
  Integer32 5..8  

pktSwchProfileDvParityA 1.3.6.1.4.1.164.8.2.1.2.1.25
This entry selects the type of parity to be checked and or generated by the PAD when radSPSProfileParTreat is a value other than 255. The options are (1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity.
OBJECT-TYPE    
  INTEGER space(1), mark(2), even(3), odd(4), none(255)  

pktSwchProfileStopBitsA 1.3.6.1.4.1.164.8.2.1.2.1.26
This entry indicates the number of stop bits per character supported by the PAD. The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits.
OBJECT-TYPE    
  INTEGER one(1), two(2), oneAndHalf(3)  

pktSwchProfileSpecFlowA 1.3.6.1.4.1.164.8.2.1.2.1.27
This entry is used to define additional flow control possiblilites. The options are either (1) Flow control by means fo the terminal DTR line or (2) No special flow control.
OBJECT-TYPE    
  INTEGER spec(1), noSpec(2)  

pktSwchProfileCountFwdA 1.3.6.1.4.1.164.8.2.1.2.1.28
This entry can be used to instruct the PAD to complete the assembly of a packet and to forward it after the specifed number of characters has been received. If the value is zero, count forwarding is disabled.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileEscDelayA 1.3.6.1.4.1.164.8.2.1.2.1.29
This entry can be used to instruct the PAD whether to delay the forwarding of a data packet when an escape character is detected in the data stream and to determine the required delay. The packet forwarding is delayed until the specified number of characters is received after the escape character. A value of zero indicates no special handling.
OBJECT-TYPE    
  Integer32 1..255  

pktSwchProfileCharBreakA 1.3.6.1.4.1.164.8.2.1.2.1.30
This entry specifies the decimal value of the character that will be interpreted as an additional break signal by the PAD. A value of zero indicates no break character.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileCharSuppressA 1.3.6.1.4.1.164.8.2.1.2.1.31
This entry specifies the decimal value of the character that will toggle echo suppression in the PAD. A value of zero indicates that echo suppression is only controlled by radSPSProfileEcho.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileCharSubsA 1.3.6.1.4.1.164.8.2.1.2.1.32
This entry specifies the decimal value of the character that will be echoed instead of the character received from the user's DTE. A zero value indicates that no character is echoed.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileFormFeedPadA 1.3.6.1.4.1.164.8.2.1.2.1.33
This entry specifies the number of padding (NUL) characters that will be automatically sent after the form feed character.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchProfileInactivityA 1.3.6.1.4.1.164.8.2.1.2.1.34
This entry specifies the number of minutes after which the PAD will forward the accumulated data and clear the call. A zero value indicates no disconnection on inactivity.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileOptionsA 1.3.6.1.4.1.164.8.2.1.2.1.35
This entry defines several options to control the profile. The value is a sum of values (powers of two), where each value in the sum represents an option . The values that may be included in the sum and their meanings are: 0 No options 1 Remote set of local X.3 parameters though X.29 is disabled 2 Add sub address to call request 4 Don't use protocol ID in user data field. 8 SPRINT NUI format 16 More bit is set when the edit buffer is full 32 Extended error message 64 Discard connect extended service signal 128 enable connect by typing the address w/out a command
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileClrTimerA 1.3.6.1.4.1.164.8.2.1.2.1.36
This entry specifies the number of minutes after which a call is cleared. If the parameter value is 0, there is no disconnection timer.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchProfileSubAddInCUDA 1.3.6.1.4.1.164.8.2.1.2.1.37
This entry defines the number of digits for the subaddress in CUD.
OBJECT-TYPE    
  Integer32 0..5  

pktSwchChannel 1.3.6.1.4.1.164.8.2.2
OBJECT IDENTIFIER    

pktSwchChannelSTable 1.3.6.1.4.1.164.8.2.2.1
The Scratch Channel Table defines the channels configured on the PS.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchChannelSEntry

pktSwchChannelSEntry 1.3.6.1.4.1.164.8.2.2.1.1
Defines the contents of each line in the Scratch Channel Table.
OBJECT-TYPE    
  PktSwchChannelSEntry  

pktSwchChannelIfIndexS 1.3.6.1.4.1.164.8.2.2.1.1.1
This is used as the index for the channel table.
OBJECT-TYPE    
  Integer32  

pktSwchChannelNumberS 1.3.6.1.4.1.164.8.2.2.1.1.2
The number by which a channel is identified.
OBJECT-TYPE    
  Integer32 1..1224  

pktSwchChannelProfileS 1.3.6.1.4.1.164.8.2.2.1.1.3
The profile that the channel uses for command mode operations.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchChannelOutCallProfileS 1.3.6.1.4.1.164.8.2.2.1.1.4
The number of the profile that will be used during an outgoing call on the channel.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchChannelInCallProfileS 1.3.6.1.4.1.164.8.2.2.1.1.5
The number of the profile that will be used during an incoming call on the channel.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchChannelRemoteProfileS 1.3.6.1.4.1.164.8.2.2.1.1.6
The number of the profile that will be downloaded to the remote PAD at the beginning of a new call.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchChannelAutocallIdS 1.3.6.1.4.1.164.8.2.2.1.1.7
Selects the mnemonic (call ID) to be used as the first alternative. A value of zero indicates that the autocall function is disabled.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchChannelAlterAutocallIdS 1.3.6.1.4.1.164.8.2.2.1.1.8
Selects the alternate mnemonic for the autocall function. A value of zero indicates that the alternate destination is not used.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchChannelAutocallRetriesS 1.3.6.1.4.1.164.8.2.2.1.1.9
The number of autocall retries if the autocall setup request is rejected with a busy cause.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchChannelAutocallIntervalS 1.3.6.1.4.1.164.8.2.2.1.1.10
The interval in seconds between consecutive autocall retries.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchChannelCallAliasS 1.3.6.1.4.1.164.8.2.2.1.1.11
The alias to be sent after the call is set up. A value of zero indicates that alias sending is disabled. The aliases are configured on the Alias Table.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchChannelSubAddress1S 1.3.6.1.4.1.164.8.2.2.1.1.12
The first subaddress for the channel.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchChannelSubAddress2S 1.3.6.1.4.1.164.8.2.2.1.1.13
The second subaddress for the channel.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchChannelNUISEntry 1.3.6.1.4.1.164.8.2.2.1.1.14
The number corresponding to the NUI information to be sent. This number is the same as the pktSwchNuiGroupId.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchChannelClearTimerS 1.3.6.1.4.1.164.8.2.2.1.1.15
Time limitation for an open session. A value of zero indicates that the Clear timer is not used.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchChannelOptionsS 1.3.6.1.4.1.164.8.2.2.1.1.16
This controls the use of gneral non-correlated channel options. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 HW signal is checked 2 Auto call after clear 4 Auto call after 8 DCD is ON, only in DATA TRANSFER mode 16 Charging Info Facility 32 Auto call if HW signal is set 64 Accept calls even if HW signal is is OFF 128 A transparent channel.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchChannelClear 1.3.6.1.4.1.164.8.2.2.1.1.17
The Clearing Channel operation disconnects all sessions
OBJECT-TYPE    
  INTEGER noOp(1), clear(2)  

pktSwchChannelCopyTo 1.3.6.1.4.1.164.8.2.2.1.1.18
The destination channel number, to which the Copy is performed.
OBJECT-TYPE    
  Integer32  

pktSwchChannelCopyToWMask 1.3.6.1.4.1.164.8.2.2.1.1.19
The destination channel number, to which the Copy with Mask is performed.
OBJECT-TYPE    
  Integer32  

pktSwchChannelCopyMask 1.3.6.1.4.1.164.8.2.2.1.1.20
The selected configuration parameters to be copied from the source channel to the target channels. The value is a sum of values (powers of two), where each value in the sum represents a selected parameter that is not copied. The values that may be included in the sum and their meanings are: 0 Copy all. 1 Do not copy Profile. 2 Do not copy OutCallProfile. 4 Do not copy InCallProfile. 8 Do not copy RemoteProfile. 16 Do not copy AutocallId. 32 Do not copy AlterCallId. 64 Do not copy AutoCallRetries. 128 Do not copy AutoCallInterval. 256 Do not copy CallAlias. 512 Do not copy SubAddress1. 1024 Do not copy SubAddress2. 2048 Do not copy NUIEntry. 4096 Do not copy ClearTimer. 8192 Do not copy Options. XXX - Any combination of the above.
OBJECT-TYPE    
  Integer32 0..16383  

pktSwchChannelATable 1.3.6.1.4.1.164.8.2.2.2
The Active Channel Table defines the channels configured on the PS.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchChannelAEntry

pktSwchChannelAEntry 1.3.6.1.4.1.164.8.2.2.2.1
Defines the contents of each line in the Active Channel Table.
OBJECT-TYPE    
  PktSwchChannelAEntry  

pktSwchChannelIfIndexA 1.3.6.1.4.1.164.8.2.2.2.1.1
This is used as the index for the channel table.
OBJECT-TYPE    
  Integer32  

pktSwchChannelNumberA 1.3.6.1.4.1.164.8.2.2.2.1.2
The number by which a channel is identified.
OBJECT-TYPE    
  Integer32 1..288  

pktSwchChannelProfileA 1.3.6.1.4.1.164.8.2.2.2.1.3
The profile that the channel uses for command mode operations.
OBJECT-TYPE    
  Integer32  

pktSwchChannelOutCallProfileA 1.3.6.1.4.1.164.8.2.2.2.1.4
The number of the profile that is used during an outgoing call on the channel.
OBJECT-TYPE    
  Integer32  

pktSwchChannelInCallProfileA 1.3.6.1.4.1.164.8.2.2.2.1.5
The number of the profile that is used during an incoming call on the channel.
OBJECT-TYPE    
  Integer32  

pktSwchChannelRemoteProfileA 1.3.6.1.4.1.164.8.2.2.2.1.6
The number of the profile that is downloaded to the remote PAD at the beginning of a new call.
OBJECT-TYPE    
  Integer32  

pktSwchChannelAutocallIdA 1.3.6.1.4.1.164.8.2.2.2.1.7
Selects the mnemonic (call ID) to be used as the first alternative. A value of zero indicates that the autocall function is disabled.
OBJECT-TYPE    
  Integer32  

pktSwchChannelAlterAutocallIdA 1.3.6.1.4.1.164.8.2.2.2.1.8
Selects the alternate mnemonic for the autocall function. A value of zero indicates that the alternate destination is not used.
OBJECT-TYPE    
  Integer32  

pktSwchChannelAutocallRetriesA 1.3.6.1.4.1.164.8.2.2.2.1.9
The number of autocall retrues if the autocall setup request is rejected with a busy cause.
OBJECT-TYPE    
  Integer32  

pktSwchChannelAutocallIntervalA 1.3.6.1.4.1.164.8.2.2.2.1.10
The interval in seconds between consecutive autocall retries.
OBJECT-TYPE    
  Integer32  

pktSwchChannelCallAliasA 1.3.6.1.4.1.164.8.2.2.2.1.11
The alias to be sent after the call is set up. A value of zero indicates that alias sending is disabled. The aliases are configured on the Alias Table.
OBJECT-TYPE    
  Integer32  

pktSwchChannelSubAddress1A 1.3.6.1.4.1.164.8.2.2.2.1.12
The first subaddress for the channel.
OBJECT-TYPE    
  Integer32  

pktSwchChannelSubAddress2A 1.3.6.1.4.1.164.8.2.2.2.1.13
The second subaddress for the channel.
OBJECT-TYPE    
  Integer32  

pktSwchChannelNUIAEntry 1.3.6.1.4.1.164.8.2.2.2.1.14
The number corresponding to the NUI information to be sent. This number is the same as the pktSwchNuiIndex.
OBJECT-TYPE    
  Integer32  

pktSwchChannelClearTimerA 1.3.6.1.4.1.164.8.2.2.2.1.15
Time limitation for an open session. A value of zero indicates that the Clear timer is not used.
OBJECT-TYPE    
  Integer32  

pktSwchChannelOptionsA 1.3.6.1.4.1.164.8.2.2.2.1.16
This controls the use of general non-correlated channel options. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 RTS line checked 2 Auto call after clear 4 Auto call after 8 DCD is ON, only in DATA TRANSFER mode. 16 Charging Info Facility 32 Auto call if HW signal is set 64 Accept calls even if HW signal is is OFF 128 A transparent channel.
OBJECT-TYPE    
  Integer32  

pktSwchCallId 1.3.6.1.4.1.164.8.2.3
OBJECT IDENTIFIER    

pktSwchCallIdSTable 1.3.6.1.4.1.164.8.2.3.1
The Call ID Table S defines the Scratch Call IDs configured on the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchCallIdSEntry

pktSwchCallIdSEntry 1.3.6.1.4.1.164.8.2.3.1.1
Defines the contents of each line in the Scratch CallId Table.
OBJECT-TYPE    
  PktSwchCallIdSEntry  

pktSwchCallIdNumberS 1.3.6.1.4.1.164.8.2.3.1.1.1
The index of this entry.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchCallIdMnemonicS 1.3.6.1.4.1.164.8.2.3.1.1.2
The mnemonic for this call ID.
OBJECT-TYPE    
  DisplayString  

pktSwchCallIdAddressS 1.3.6.1.4.1.164.8.2.3.1.1.3
The address for this call ID.
OBJECT-TYPE    
  DisplayString  

pktSwchCallIdStatusS 1.3.6.1.4.1.164.8.2.3.1.1.4
The status of this Call ID table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchCallIdATable 1.3.6.1.4.1.164.8.2.3.2
The Call ID Table A defines the Active Call IDs configured on the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchCallIdAEntry

pktSwchCallIdAEntry 1.3.6.1.4.1.164.8.2.3.2.1
Defines the contents of each line in the Active CallId Table.
OBJECT-TYPE    
  PktSwchCallIdAEntry  

pktSwchCallIdNumberA 1.3.6.1.4.1.164.8.2.3.2.1.1
The index of this entry.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchCallIdMnemonicA 1.3.6.1.4.1.164.8.2.3.2.1.2
The mnemonic for this call ID.
OBJECT-TYPE    
  DisplayString  

pktSwchCallIdAddressA 1.3.6.1.4.1.164.8.2.3.2.1.3
The address for this call ID.
OBJECT-TYPE    
  DisplayString  

pktSwchAlias 1.3.6.1.4.1.164.8.2.4
OBJECT IDENTIFIER    

pktSwchAliasSTable 1.3.6.1.4.1.164.8.2.4.1
The Alias Table defines the aliases configured on the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchAliasSEntry

pktSwchAliasSEntry 1.3.6.1.4.1.164.8.2.4.1.1
Defines the contents of each line in the Alias Table.
OBJECT-TYPE    
  PktSwchAliasSEntry  

pktSwchAliasNumberS 1.3.6.1.4.1.164.8.2.4.1.1.1
The index of this entry.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchAliasValueS 1.3.6.1.4.1.164.8.2.4.1.1.2
The alias is defined using up to 64 characters.
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

pktSwchAliasStatusS 1.3.6.1.4.1.164.8.2.4.1.1.3
The status of this Alias table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchAliasATable 1.3.6.1.4.1.164.8.2.4.2
The Alias Table defines the aliases configured on the device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchAliasAEntry

pktSwchAliasAEntry 1.3.6.1.4.1.164.8.2.4.2.1
Defines the contents of each line in the Alias Table.
OBJECT-TYPE    
  PktSwchAliasAEntry  

pktSwchAliasNumberA 1.3.6.1.4.1.164.8.2.4.2.1.1
The index of this entry.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchAliasValueA 1.3.6.1.4.1.164.8.2.4.2.1.2
The alias is defined using up to 64 characters.
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

pktSwchAsyncStatTable 1.3.6.1.4.1.164.8.2.5
The AsyncStat Table includes status information and statistics provided by the PS on the async channels.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchAsyncStatEntry

pktSwchAsyncStatEntry 1.3.6.1.4.1.164.8.2.5.1
Defines the contents of each line in the Async Stat Table.
OBJECT-TYPE    
  PktSwchAsyncStatEntry  

pktSwchAsyncIfIndex 1.3.6.1.4.1.164.8.2.5.1.1
An index for the table.
OBJECT-TYPE    
  Integer32  

pktSwchAsyncChannelNumber 1.3.6.1.4.1.164.8.2.5.1.2
The channel to which this entry applies. This value is the same as the pktSwchChannelNumber.
OBJECT-TYPE    
  Integer32  

pktSwchAsyncConnectionStatus 1.3.6.1.4.1.164.8.2.5.1.3
The connection status of the channel is either FREE or ENG (engaged).
OBJECT-TYPE    
  INTEGER engaged(1), free(2)  

pktSwchAsyncNumLogChannels 1.3.6.1.4.1.164.8.2.5.1.4
The number of active logical channels used by the asynchronous channel.
OBJECT-TYPE    
  Integer32  

pktSwchAsyncNumActSessions 1.3.6.1.4.1.164.8.2.5.1.5
The number of active sessions opened by this asynchronous channel.
OBJECT-TYPE    
  Integer32  

pktSwchAsyncAutocallId 1.3.6.1.4.1.164.8.2.5.1.6
Indicates whether the channel has been configured to use the autocall function and what is the call ID. NONE means that the channel is not configured for autocall.
OBJECT-TYPE    
  Integer32  

pktSwchAsyncRTSStatus 1.3.6.1.4.1.164.8.2.5.1.7
Shows the status of the RTS line of the asynchronous channel. OFF indicates that the RTS line is not active, ON indicates that it is active, and UNUSED indicates that the channel PAD is programmed to disregard the state of the RTS line.
OBJECT-TYPE    
  INTEGER unused(1), off(2), on(3)  

pktSwchAsyncBuffToNet 1.3.6.1.4.1.164.8.2.5.1.8
The number of data buffers currently used by the transmit direction of the channel.
OBJECT-TYPE    
  Integer32  

pktSwchAsyncBuffToUser 1.3.6.1.4.1.164.8.2.5.1.9
The number of data buffers currently used by the receive direction of the channel.
OBJECT-TYPE    
  Integer32  

pktSwchAsyncTxXoff 1.3.6.1.4.1.164.8.2.5.1.10
The current state of software flow control in the transmit direction. NO indicates that traffic flow is enabled. YES indicates that traffic flow from the user's DTE to the device channel has been interrupted by sending the X-OFF character to the DTE.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pktSwchAsyncRxXoff 1.3.6.1.4.1.164.8.2.5.1.11
The current state of software flow control in the receive direction. NO indicates that traffic flow is enabled. YES indicates that traffic flow to the user's DTE from the device channel has been interrupted by means of the X-OFF character.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

pktSwchAsyncBuffOutstand 1.3.6.1.4.1.164.8.2.5.1.12
Indicates the number of buffers which were sent to the async user but weren't yet freed.
OBJECT-TYPE    
  Integer32  

pktSwchAsyncChannelMode 1.3.6.1.4.1.164.8.2.5.1.13
The channel mode is either X28 COMMAND or DATA TRANSFER.
OBJECT-TYPE    
  INTEGER none(1), activeLink(2), x28command(3), dataTransfer(4)  

pktSwchAsyncRunProTable 1.3.6.1.4.1.164.8.2.6
The AsyncRunPro Table includes status information and statistics provided by the PS on the async channels.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchAsyncRunProEntry

pktSwchAsyncRunProEntry 1.3.6.1.4.1.164.8.2.6.1
Defines the contents of each line in the Async RunPro Table.
OBJECT-TYPE    
  PktSwchAsyncRunProEntry  

pktSwchAsyncRunProIfIndex 1.3.6.1.4.1.164.8.2.6.1.1
An index for the table.
OBJECT-TYPE    
  Integer32  

pktSwchAsyncRunProChannelNumber 1.3.6.1.4.1.164.8.2.6.1.2
The channel to which this entry applies. This value is the same as the pktSwchChannelNumber.
OBJECT-TYPE    
  Integer32  

pktSwchAsyncRunProRecallChar 1.3.6.1.4.1.164.8.2.6.1.3
The character specified by this entry is used to escape from the data transfer mode and enter the PAD command mode. The integer values have the following meanings: (0) PAD recall is not possible (1) The PAD recall character is DLE (2) to (126) The PAD recall character is specified by the user by entering its ASCII code.
OBJECT-TYPE    
  Integer32 0..126  

pktSwchAsyncRunProEcho 1.3.6.1.4.1.164.8.2.6.1.4
This determines if an echo of the input characters is retured to the DTE. The options are either 'echo enabled' or 'no echo'.
OBJECT-TYPE    
  INTEGER echEn(1), noEch(2)  

pktSwchAsyncRunProDataForwChar 1.3.6.1.4.1.164.8.2.6.1.5
The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) used as a data forwarding character. The data forwarding characters are used to instruct the PAD to complete the assembly of and to forward a packet containing the data accumulated up to the reception of such a character. The values that may be included in the sum and their meanings are: 0 Data forwarding characters are not used 1 Alpha-numeric characters (A to Z, a to z, 0 to 9, inclusive) 2 Character CR 4 Characters ESC, BEL, ENQ, ACK 8 Characters DEL, CAN, DC2 16 Characters EOT, ETX 32 Characters HT, LF, VT, FF 64 All the other characters in colums 0 and 1 of IA5 and not listed above.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchAsyncRunProIdleTimer 1.3.6.1.4.1.164.8.2.6.1.6
Packets will be forwarded when the idle timer expires. The idle time interval is specified as a multiple of 50 milliseconds. The multiple is given by the parameter value. For example, a value of 60 sets an interval of 3 seconds. If the parameter value is 0, no forwarding occurs after the idle condition.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchAsyncRunProDevFlowCont 1.3.6.1.4.1.164.8.2.6.1.7
This parameter determines whether or not the PAD uses software flow control for the attached device. The options are either (1) PAD uses flow control during data transfer mode, (2) PAD uses flow control both in the data transfer mode and in the command mode, or (255) PAD does not use flow control.
OBJECT-TYPE    
  INTEGER trans(1), transAndCom(2), noFlow(255)  

pktSwchAsyncRunProServSig 1.3.6.1.4.1.164.8.2.6.1.8
This parameter is used to instruct the PAD whether to transfer PAD service signals and the PAD prompt to the local DTE in standard format. The options are (1) PAD service signals are transmitted to the DTE using the standard format, (4) The PAD prompt is transmitted using the standard format, (5) PAD service signals and the PAD prompt are transmitted in the standard format, or (255) No PAD service signals are transmitted to the DTE.
OBJECT-TYPE    
  INTEGER serv(1), prompt(4), servAndPrompt(5), noSig(255)  

pktSwchAsyncRunProBreak 1.3.6.1.4.1.164.8.2.6.1.9
The value is a sum of values (powers of two), where each value in the sum represents a PAD operation on receipt of the break signal from the DTE. The values that may be included in the sum and their meanings are: 0 Nothing 1 Send interrupt packet to network 2 Send RESET packet to network 4 Send and 'indication of break' message 8 Escape from data transfer mode 16 Discard output data waiting to be sent to the DTE .
OBJECT-TYPE    
  Integer32 0..31  

pktSwchAsyncRunProDiscOut 1.3.6.1.4.1.164.8.2.6.1.10
This parameter instructs the PAD whether to forward the user sequences included in data packets to the local DTE or discard them. The options are (1) discard output or (2) normal data delivery. If the value of radSPSProfileBreak is 21, the value of pktSwchAsyncRunProDiscOut is automatically set to (1) when a break signal is received.
OBJECT-TYPE    
  INTEGER discOut(1), normal(2)  

pktSwchAsyncRunProCRPPadding 1.3.6.1.4.1.164.8.2.6.1.11
This parameter specifies the number of padding characters to be added after a carriage return character is transmitted to the local DTE.
OBJECT-TYPE    
  Integer32 0..127  

pktSwchAsyncRunProLineFold 1.3.6.1.4.1.164.8.2.6.1.12
This parameter specifies the maximum number of characters to be inserted before the format effector. If the value is zero, there is no insertion of a format effector (line folding).
OBJECT-TYPE    
  Integer32 0..255  

pktSwchAsyncRunProSpeed 1.3.6.1.4.1.164.8.2.6.1.13
This parameter determines the rate of data transmission to and from the DTE.
OBJECT-TYPE    
  INTEGER s110bps(1), s300bps(2), s1200bps(3), s600bps(4), s75bps(5), s150bps(6), s2400bps(12), s4800bps(13), s9600bps(14), s19200bps(15), s38400bps(19), s57600bps(20), s115200bps(21)  

pktSwchAsyncRunProPadFlowCont 1.3.6.1.4.1.164.8.2.6.1.14
This determines whether or not the terminal can exercise flow control over the PAD. The options are either 'device can exercise flow control' or 'device cannot exercise flow control.
OBJECT-TYPE    
  INTEGER flowCont(1), noFlowCont(2)  

pktSwchAsyncRunProLineFeedInsert 1.3.6.1.4.1.164.8.2.6.1.15
This parameter indicates when there is a line feed insertion after CR. The options are (1) Insert line feed after transmission of CR to the DTE, (2) Insert line feed after receipt of CR from the DTE, (4) Insert line feed after echoing a CR character to the DTE, (5) Combination of (1) and (4), (6) Insert line feed after any CR to the DTE (combination of (2) and (4)), (7) Combination of (1), (2), and (4), or (255) No line feed insertion.
OBJECT-TYPE    
  INTEGER afterCR(1), recCR(2), echoCR(4), onePlusFour(5), twoPlusFour(6), oneTwoFour(7), noFeed(255)  

pktSwchAsyncRunProLineFeedPad 1.3.6.1.4.1.164.8.2.6.1.16
This parameter specifies the number of padding characters to be added after a line feed.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchAsyncRunProEditing 1.3.6.1.4.1.164.8.2.6.1.17
This parameter specifies the editing capabilities available in the data transfer mode. Editing is always possible when the PAD is in the command mode. The options are (1) Command editing in the data trasfer mode is enabled or (2) No command editing in the data transfer mode.
OBJECT-TYPE    
  INTEGER edit(1), noEdit(2)  

pktSwchAsyncRunProCharDel 1.3.6.1.4.1.164.8.2.6.1.18
This parameter specifies the character delete, which is one character from IA5. The default selection is 127 (character DEL).
OBJECT-TYPE    
  Integer32 0..127  

pktSwchAsyncRunProLineDel 1.3.6.1.4.1.164.8.2.6.1.19
This parameter specifies the line delete, which is one character from IA5. The default selection is 24 (character CAN).
OBJECT-TYPE    
  Integer32 0..127  

pktSwchAsyncRunProLineDisp 1.3.6.1.4.1.164.8.2.6.1.20
This entry specifies the line display character, which is one character from IA5. The default selection is 18 (character DC2).
OBJECT-TYPE    
  Integer32 0..127  

pktSwchAsyncRunProEditServSig 1.3.6.1.4.1.164.8.2.6.1.21
This entry specifies the editing PAD service signals. The integer values have the following meanings: (0) No editing PAD service signals (1) Editing PAD service signals for printing terminals (2) Editing PAD service signals for display terminals (3) to (126) Editing PAD service signals using the desired character from IA5.
OBJECT-TYPE    
  Integer32 0..126  

pktSwchAsyncRunProEchomask 1.3.6.1.4.1.164.8.2.6.1.22
The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) included in the echo mask. The characters in the echo mask are not echoed to the DTE when PAD echo is enabled. The values that may be included in the sum and their meanings are: 0 No echo mask (all the characters are echoed) 1 No echo of character CR 2 No echo of character LF 4 No echo of characters VT, HT, FF 8 No echo of characters BEL, BS 16 No echo of characters ESC, ENQ 32 No echo of characters ACK, NAK, STX, SOH, EOT, ETB, ETX 64 No echo of the editing characters selected by radSPSProfileCharDel, radSPSProfileLineDel, and radSPSProfileLineDisp 128 No echo of the DEL character and of all the other characters in the range of ASCII 00 through 31 not mentioned above.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchAsyncRunProParTreat 1.3.6.1.4.1.164.8.2.6.1.23
This entry controls the generation of parity bits in the data sent to the local DTE and the checking of the parity bit when generated by the local DTE. The options are (1) parity checking is enabled, (2) parity generation is enabled, (3) parity checking and generation are enabled, or (255) no parity checking nor parity generation.
OBJECT-TYPE    
  INTEGER parCheck(1), parGen(2), checkAndGen(3), noPar(255)  

pktSwchAsyncRunProPageWait 1.3.6.1.4.1.164.8.2.6.1.24
This entry specifies the number of line feed characters counted by the PAD before the page wait condition is entered. If the value is zero, page wait is disabled.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchPhyInterfaceTable 1.3.6.1.4.1.164.8.3
The Link Table defines the links configured on the PS.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchPhyInterfaceEntry

pktSwchPhyInterfaceEntry 1.3.6.1.4.1.164.8.3.1
Defines the contents of each line in the Link Table.
OBJECT-TYPE    
  PktSwchPhyInterfaceEntry  

pktSwchPhyInterfaceIfIndex 1.3.6.1.4.1.164.8.3.1.1
The ifIndex identified with this link.
OBJECT-TYPE    
  Integer32  

pktSwchPhyInterfaceProtocolS 1.3.6.1.4.1.164.8.3.1.2
The protocol to be used on this link. Note for PPP: PPP protocol is allowed to be applied on Sync Links (1-3) as well as Async channels (1-24). In order to eliminate ambiguity in the IP destination where a destination of P1 can be used for example for async channel 1 and Sync Link 1, it was decided NOT TO ALLOW configuring PPP on both Sync Link no. 1 and async channel 1. Same for Link 2 and Link 3.
OBJECT-TYPE    
  INTEGER x25(1), frameRelay(2), hdlc(3), sdlc(4), async(5), stm4(6), stm8(7), stm16(8), stm24(9), mpe(10), bscHpad(11), bscTpad(12), slip(13), ethernet(14), ppp(15)  

pktSwchPhyInterfaceProtocolA 1.3.6.1.4.1.164.8.3.1.3
The protocol currently used on this link.
OBJECT-TYPE    
  INTEGER x25(1), frameRelay(2), hdlc(3), sdlc(4), async(5), stm4(6), stm8(7), stm16(8), stm24(9), mpe(10), bscHpad(11), bscTpad(12), slip(13), ethernet(14), ppp(15)  

pktSwchPhyInterfaceCopyTo 1.3.6.1.4.1.164.8.3.1.4
The destination interface number, to which the Copy is performed.
OBJECT-TYPE    
  Integer32  

pktSwchPhyInterfaceChanged 1.3.6.1.4.1.164.8.3.1.5
Indicates if the current running protocol is different than the defined protocol
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

pktSwchPhyInterfaceRxBuffInPool 1.3.6.1.4.1.164.8.3.1.6
The free data buffers in the Rx pool per interface
OBJECT-TYPE    
  Integer32  

pktSwchPhyInterfaceConnector 1.3.6.1.4.1.164.8.3.1.7
The connector type of the interface
OBJECT-TYPE    
  INTEGER v24(2), v35(3), x21(4), rs530(5), acd(6), mobi(7), u(8), etherUtp(9), noConnector(255)  

pktSwchPhyInterfaceNeighborIp 1.3.6.1.4.1.164.8.3.1.8
The Ip address of the device on the other side of the link.
OBJECT-TYPE    
  IpAddress  

pktSwchPhyInterfaceProtocolStatus 1.3.6.1.4.1.164.8.3.1.9
The status of the Interface Protocol row in the Table.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchPhyInterfaceTestCmd 1.3.6.1.4.1.164.8.3.1.10
START/STOP a test on the current interface. The available tests are: v54Local - Local Analog Loopback (AL), L3 according to ITU-T standard. v54Remote - Remote Digital Loopback(RDL), L2 according to ITU-T standard. For stopping the test, SET the noOp (1) option.
OBJECT-TYPE    
  INTEGER noOp(1), v54Local(2), v54Remote(3)  

pktSwchPhyInterfaceTestTransmittedFrames 1.3.6.1.4.1.164.8.3.1.11
No. of frames which were transmitted from this interface during the TEST.
OBJECT-TYPE    
  Counter32  

pktSwchPhyInterfaceTestReceivedFrames 1.3.6.1.4.1.164.8.3.1.12
No. of frames which were received on this interface during the TEST.
OBJECT-TYPE    
  Counter32  

pktSwchPhyInterfaceTestLostFrames 1.3.6.1.4.1.164.8.3.1.13
Percentage of the frames which were lost during the TEST.
OBJECT-TYPE    
  Integer32  

pktSwchx25 1.3.6.1.4.1.164.8.4
OBJECT IDENTIFIER    

pktSwchLapb 1.3.6.1.4.1.164.8.4.1
OBJECT IDENTIFIER    

pktSwchLapbSTable 1.3.6.1.4.1.164.8.4.1.1
The Lapb Table includes statistics and configurable objects provided by the PS that are not included in RFC 1381.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchLapbSEntry

pktSwchLapbSEntry 1.3.6.1.4.1.164.8.4.1.1.1
Defines the contents of each line in the RAD Lapb Table.
OBJECT-TYPE    
  PktSwchLapbSEntry  

pktSwchLapbLinkNumberS 1.3.6.1.4.1.164.8.4.1.1.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is X.25 and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame Relay and the DLCI is defined as using X.25.
OBJECT-TYPE    
  Integer32  

pktSwchLapbInternalClockS 1.3.6.1.4.1.164.8.4.1.1.1.2
The internal clock speed to be used on this LAPB link. If external clock is used, the value is 255.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r504Kbps(13), r768Kbps(14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255)  

pktSwchLapbLineOptionS 1.3.6.1.4.1.164.8.4.1.1.1.3
The line option to be used on this link. A value of zero indicates no options. A value between 0 and 255 inclusive specifes a time in minutes after which the line will be disconnected if no session is open. The following values have the associated meanings: 256 Dialed line 512 Return to leased line 1024 DTR is ON permanent 2048 DTR is OFF permanent. any valid combination of the above options should be represented as a sum of the corresponding values. Valid combinations are: DTR ON or OFF (but not both). Dialed line options or not applicable. If DTR control is on (256), then all combinations are possible except 1024 and 2048 (which are not possible).
OBJECT-TYPE    
  Integer32 0..2048  

pktSwchLapbSegmentSizeS 1.3.6.1.4.1.164.8.4.1.1.1.4
This value is for the use of billing information. The value can be no larger than the maximum packet size.
OBJECT-TYPE    
  Integer32 1..4096  

pktSwchLapbXIDS 1.3.6.1.4.1.164.8.4.1.1.1.5
When this parameter is different than zero, this lapb is configured as a V25 bis dialed link. This is the XID entry Index which this dialed link is associated with.
OBJECT-TYPE    
  Integer32  

pktSwchLapbAckCounterS 1.3.6.1.4.1.164.8.4.1.1.1.6
This object defines how many frames will be received on the link before the PS will send Acknowledge (RR frame). It is used for Piggy Back Acknowledge (ack within the info frames) and saves traffic on the line. Default value: 1 .
OBJECT-TYPE    
  Integer32 1..128  

pktSwchLapbAckTimerS 1.3.6.1.4.1.164.8.4.1.1.1.7
The Ack Timer defines the maximum time in seconds that the device will wait before sending RR acknowledgment on the received frames. It is used for Piggy Back Acknowledge (ack within the info frames) and saves traffic on the line. Default value: 0 .
OBJECT-TYPE    
  Integer32 0..255  

pktSwchLapbATable 1.3.6.1.4.1.164.8.4.1.2
The Lapb Table includes statistics and configurable objects provided by the PS that are not included in RFC 1381.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchLapbAEntry

pktSwchLapbAEntry 1.3.6.1.4.1.164.8.4.1.2.1
Defines the contents of each line in the RAD Lapb Table.
OBJECT-TYPE    
  PktSwchLapbAEntry  

pktSwchLapbLinkNumberA 1.3.6.1.4.1.164.8.4.1.2.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is X.25 and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame Relay and theDLCI is defined as using X.25.
OBJECT-TYPE    
  Integer32  

pktSwchLapbInternalClockA 1.3.6.1.4.1.164.8.4.1.2.1.2
The internal clock speed currently used on this LAPB link. If external clock is used, the value is 255.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r504Kbps(13), r768Kbps(14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255)  

pktSwchLapbLineOptionA 1.3.6.1.4.1.164.8.4.1.2.1.3
The line option currently used on this link. A value of zero indicates no options. A value between 1 and 255 inclusive specifes a time in minutes after which the line will be disconnected if no session is open. The following values have the associated meanings: 256 Dialed line 512 Return to leased line 1024 DTR is ON permanent 2048 DTR is OFF permanent. any valid combination of the above options should be represented as a sum of the corresponding values. Valid combinations are: DTR ON or OFF (but not both). Dialed line options or not applicable. If DTR control is on (256), then all combinations are possible except 1024 and 2048 (which are not possible).
OBJECT-TYPE    
  Integer32 0..2048  

pktSwchLapbSegmentSizeA 1.3.6.1.4.1.164.8.4.1.2.1.4
The current value of the segment size.
OBJECT-TYPE    
  Integer32 1..4096  

pktSwchLapbLineProtocol 1.3.6.1.4.1.164.8.4.1.2.1.5
This is the lower level protocol which runs under this lapb interface.
OBJECT-TYPE    
  INTEGER unknown(1), x25(2), fr(3), isdn(4)  

pktSwchLapbLowerId 1.3.6.1.4.1.164.8.4.1.2.1.6
In case of X.25 over Frame-relay this is the lower level link number.
OBJECT-TYPE    
  Integer32  

pktSwchLapbXIDA 1.3.6.1.4.1.164.8.4.1.2.1.7
When this parameter is different than zero, this lapb is configured as a V25 bis dialed link. This is the XID entry which this dialed link is associated with.
OBJECT-TYPE    
  Integer32  

pktSwchLapbTransmittedIFrames 1.3.6.1.4.1.164.8.4.1.2.1.8
The transmitted I frames on this link.
OBJECT-TYPE    
  Counter32  

pktSwchLapbReceivedIFrames 1.3.6.1.4.1.164.8.4.1.2.1.9
The received I frames on this link.
OBJECT-TYPE    
  Counter32  

pktSwchLapbNSError 1.3.6.1.4.1.164.8.4.1.2.1.10
The number of I frames transmitted out of sequence.
OBJECT-TYPE    
  Counter32  

pktSwchLapbTransmittedRRFrames 1.3.6.1.4.1.164.8.4.1.2.1.11
The transmitted RR frames on this link.
OBJECT-TYPE    
  Counter32  

pktSwchLapbReceivedRRFrames 1.3.6.1.4.1.164.8.4.1.2.1.12
The received RR frames on this link.
OBJECT-TYPE    
  Counter32  

pktSwchLapbTransmittedRNRFrames 1.3.6.1.4.1.164.8.4.1.2.1.13
The transmitted RNR frames on this link.
OBJECT-TYPE    
  Counter32  

pktSwchLapbReceivedRNRFrames 1.3.6.1.4.1.164.8.4.1.2.1.14
The received RNR frames on this link.
OBJECT-TYPE    
  Counter32  

pktSwchLapbTransmittedFRMRFrames 1.3.6.1.4.1.164.8.4.1.2.1.15
The transmitted FRMR frames on this link.
OBJECT-TYPE    
  Counter32  

pktSwchLapbReceivedFRMRFrames 1.3.6.1.4.1.164.8.4.1.2.1.16
The received FRMR frames on this link.
OBJECT-TYPE    
  Counter32  

pktSwchLapbAckCounterA 1.3.6.1.4.1.164.8.4.1.2.1.17
This object defines how many frames will be received on the link before the PS will send Acknowledge (RR frame). It is used for Piggy Back Acknowledge (ack within the info frames) and saves traffic on the line. Default value: 1 .
OBJECT-TYPE    
  Integer32 1..128  

pktSwchLapbAckTimerA 1.3.6.1.4.1.164.8.4.1.2.1.18
The Ack Timer defines the maximum time in seconds that the device will wait before sending RR acknowledgment on the received frames. It is used for Piggy Back Acknowledge (ack within the info frames) and saves traffic on the line. Default value: 0 .
OBJECT-TYPE    
  Integer32 0..255  

pktSwchPlp 1.3.6.1.4.1.164.8.4.2
OBJECT IDENTIFIER    

pktSwchPlpSTable 1.3.6.1.4.1.164.8.4.2.1
The Scratch Plp Table includes configurable objects provided by the PS that are not included in RFC 1382.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchPlpSEntry

pktSwchPlpSEntry 1.3.6.1.4.1.164.8.4.2.1.1
Defines the contents of each line in the RAD Scratch Plp Table.
OBJECT-TYPE    
  PktSwchPlpSEntry  

pktSwchPlpLinkNumberS 1.3.6.1.4.1.164.8.4.2.1.1.1
The ifIndex of the X.25 interface.
OBJECT-TYPE    
  Integer32  

pktSwchPlpInCallOptionS 1.3.6.1.4.1.164.8.4.2.1.1.2
The in call options for the link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Fast select acceptance - included in RFC 1382 2 Reverse charge acceptance - included in RFC 1382 4 Subaddress in Call User Data field (CUD) 8 Protocol ID (PID) is not used.
OBJECT-TYPE    
  Integer32 0..15  

pktSwchPlpOutCallOptionS 1.3.6.1.4.1.164.8.4.2.1.1.3
The out call options for the link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Don't add calling and call addressin call accept packet 2 Network link, call request spread enabled 4 Add source link number to called address 8 Don't change calling address XX - Any combination of the values specified above.
OBJECT-TYPE    
  Integer32 0..15  

pktSwchPlpCugSubscriptionS 1.3.6.1.4.1.164.8.4.2.1.1.4
The CUG subscription for the link.
OBJECT-TYPE    
  INTEGER cug(1), cugOa(2), cugIa(3), cugOaIa(4), noPref(5), noCug(255)  

pktSwchPlpNUIS 1.3.6.1.4.1.164.8.4.2.1.1.5
This is the NUI group which this Plp is part of.
OBJECT-TYPE    
  Integer32  

pktSwchPlpCpyPktSize 1.3.6.1.4.1.164.8.4.2.1.1.6
x25 packet size.
OBJECT-TYPE    
  Integer32  

pktSwchPlpCpyWinSize 1.3.6.1.4.1.164.8.4.2.1.1.7
x25 window size.
OBJECT-TYPE    
  Integer32  

pktSwchPlpATable 1.3.6.1.4.1.164.8.4.2.2
The Active Plp Table includes objects provided by the PS that are not included in RFC 1382. It also includes some packet layer statistics, some of which are defined in RFC 1382, but are not supported there, as the x25StatTable in RFC 1382 is not supported.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchPlpAEntry

pktSwchPlpAEntry 1.3.6.1.4.1.164.8.4.2.2.1
Defines the contents of each line in the RAD Active Plp Table.
OBJECT-TYPE    
  PktSwchPlpAEntry  

pktSwchPlpLinkNumberA 1.3.6.1.4.1.164.8.4.2.2.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is X.25 and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame Relay and theDLCI is defined as using X.25.
OBJECT-TYPE    
  Integer32  

pktSwchPlpInCallOptionA 1.3.6.1.4.1.164.8.4.2.2.1.2
The current in call options for the link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that can be included in the sum and their meanings are: 0 No options 1 Fast select acceptance - included in RFC 1382 2 Reverse charge acceptance - included in RFC 1382 4 Subaddress in Call User Data field (CUD) 8 Protocol ID (PID) is not used.
OBJECT-TYPE    
  Integer32 0..15  

pktSwchPlpOutCallOptionA 1.3.6.1.4.1.164.8.4.2.2.1.3
The out call options for the link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Don't add calling and call addressin call accept packet 2 Network link, call request spread enabled 4 Add source link number to called address 8 Don't change calling address XX - Any combination of the values specified above.
OBJECT-TYPE    
  Integer32 0..15  

pktSwchPlpCugSubscriptionA 1.3.6.1.4.1.164.8.4.2.2.1.4
The current CUG subscription for the link.
OBJECT-TYPE    
  INTEGER cug(1), cugOa(2), cugIa(3), cugOaIa(4), noPref(5), noCug(255)  

pktSwchPlpNUIA 1.3.6.1.4.1.164.8.4.2.2.1.5
This is the NUI group which this Plp is part of.
OBJECT-TYPE    
  Integer32  

pktSwchStatOutRestarts 1.3.6.1.4.1.164.8.4.2.2.1.6
The number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE interface. This only counts restarts received when the PLE already has an established connection with the remove PLE.
OBJECT-TYPE    
  Counter32  

pktSwchPlaceHolderForFutureUse 1.3.6.1.4.1.164.8.4.3
OBJECT IDENTIFIER    

pktSwchCug 1.3.6.1.4.1.164.8.4.4
OBJECT IDENTIFIER    

pktSwchCugSTable 1.3.6.1.4.1.164.8.4.4.1
The Scratch Cug Table lists the Closed User Groups defined to each X.25 link.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchCugSEntry

pktSwchCugSEntry 1.3.6.1.4.1.164.8.4.4.1.1
Defines the contents of each line in the Scratch RAD Cug Table.
OBJECT-TYPE    
  PktSwchCugSEntry  

pktSwchCugLinkNumberS 1.3.6.1.4.1.164.8.4.4.1.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is X.25 if the link has CUG options and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame Relay and the DLCI is defined as using X.25 if the link has CUG options.
OBJECT-TYPE    
  Integer32  

pktSwchCugIndexS 1.3.6.1.4.1.164.8.4.4.1.1.2
The index of the CUG for a specific link. The lowest indexed CUG is the preferential CUG.
OBJECT-TYPE    
  Integer32  

pktSwchCugNumberS 1.3.6.1.4.1.164.8.4.4.1.1.3
The CUG number for this entry.
OBJECT-TYPE    
  Integer32  

pktSwchCugStatus 1.3.6.1.4.1.164.8.4.4.1.1.4
The status of this CUG table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchCugATable 1.3.6.1.4.1.164.8.4.4.2
The Active Cug Table lists the active Closed User Groups defined to each X.25 link.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchCugAEntry

pktSwchCugAEntry 1.3.6.1.4.1.164.8.4.4.2.1
Defines the contents of each line in the Active RAD Cug Table.
OBJECT-TYPE    
  PktSwchCugAEntry  

pktSwchCugLinkNumberA 1.3.6.1.4.1.164.8.4.4.2.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is X.25 if the link has CUG options and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame Relay and theDLCI is defined as using X.25 if the link has CUG options.
OBJECT-TYPE    
  Integer32  

pktSwchCugIndexA 1.3.6.1.4.1.164.8.4.4.2.1.2
The index of the CUG for a specific link. The lowest indexed CUG is the preferential CUG.
OBJECT-TYPE    
  Integer32  

pktSwchCugNumberA 1.3.6.1.4.1.164.8.4.4.2.1.3
The CUG number for this entry.
OBJECT-TYPE    
  Integer32  

pktSwchLogCh 1.3.6.1.4.1.164.8.4.5
OBJECT IDENTIFIER    

pktSwchLogChAssTable 1.3.6.1.4.1.164.8.4.5.1
These objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interface has started may not be reflected in the operating PLE.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchLogChAssEntry

pktSwchLogChAssEntry 1.3.6.1.4.1.164.8.4.5.1.1
Entries of pktSwchLogChAssTable.
OBJECT-TYPE    
  PktSwchLogChAssEntry  

pktSwchLogChAssIndex 1.3.6.1.4.1.164.8.4.5.1.1.1
The ifIndex value for the X.25 Interface.
OBJECT-TYPE    
  IfIndexType  

pktSwchLogChAssLIC 1.3.6.1.4.1.164.8.4.5.1.1.2
Lowest Incoming channel.
OBJECT-TYPE    
  Integer32 0..4095  

pktSwchLogChAssHIC 1.3.6.1.4.1.164.8.4.5.1.1.3
Highest Incoming channel. A value of zero indicates no channels in this range.
OBJECT-TYPE    
  Integer32 0..4095  

pktSwchLogChAssLTC 1.3.6.1.4.1.164.8.4.5.1.1.4
Lowest Two-way channel.
OBJECT-TYPE    
  Integer32 0..4095  

pktSwchLogChAssHTC 1.3.6.1.4.1.164.8.4.5.1.1.5
Highest Two-way channel. A value of zero indicates no channels in this range.
OBJECT-TYPE    
  Integer32 0..4095  

pktSwchLogChAssLOC 1.3.6.1.4.1.164.8.4.5.1.1.6
Lowest outgoing channel.
OBJECT-TYPE    
  Integer32 0..4095  

pktSwchLogChAssHOC 1.3.6.1.4.1.164.8.4.5.1.1.7
Highest outgoing channel. A value of zero indicates no channels in this range.
OBJECT-TYPE    
  Integer32 0..4095  

pktSwchLogChPartnerTable 1.3.6.1.4.1.164.8.4.5.2
These objects contain information about the partner channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interfaces has started may not be reflected in the operating PLE.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchLogChPartnerEntry

pktSwchLogChPartnerEntry 1.3.6.1.4.1.164.8.4.5.2.1
Entries of pktSwchLogChPartnerTable.
OBJECT-TYPE    
  PktSwchLogChPartnerEntry  

pktSwchLogChPartnerIfIndex 1.3.6.1.4.1.164.8.4.5.2.1.1
The ifIndex value for the Lapb Interface.
OBJECT-TYPE    
  IfIndexType  

pktSwchLogChPartnerLcIndex 1.3.6.1.4.1.164.8.4.5.2.1.2
The Index value for the LCN.
OBJECT-TYPE    
  Integer32  

pktSwchLogChPartnerProtocol 1.3.6.1.4.1.164.8.4.5.2.1.3
The protocol of the partner.
OBJECT-TYPE    
  INTEGER other(1), x25(2), hdlc(3), sdlc(4), async(5), mpe(6), ip(7)  

pktSwchLogChPartnerOpIfIndex 1.3.6.1.4.1.164.8.4.5.2.1.4
The ifIndex value for the partner Lapb Interface.
OBJECT-TYPE    
  IfIndexType  

pktSwchLogChPartnerOpLcIndex 1.3.6.1.4.1.164.8.4.5.2.1.5
The Index value for the partner LCN.
OBJECT-TYPE    
  Integer32  

pktSwchHdlc 1.3.6.1.4.1.164.8.5
OBJECT IDENTIFIER    

pktSwchHdlcSTable 1.3.6.1.4.1.164.8.5.1
The Scratch Hdlc Table contains configuration information for HDLC links
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchHdlcSEntry

pktSwchHdlcSEntry 1.3.6.1.4.1.164.8.5.1.1
Defines the contents of each line in the RAD Hdlc Table.
OBJECT-TYPE    
  PktSwchHdlcSEntry  

pktSwchHdlcLinkNumberS 1.3.6.1.4.1.164.8.5.1.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is HDLC.
OBJECT-TYPE    
  Integer32  

pktSwchHdlcDestAddrS 1.3.6.1.4.1.164.8.5.1.1.2
The destination address. It defines the X.25 address on the remote device.
OBJECT-TYPE    
  DisplayString  

pktSwchHdlcDestSubAddrS 1.3.6.1.4.1.164.8.5.1.1.3
The destination subaddress. It defines the synchronous link subaddress on the remote device.
OBJECT-TYPE    
  Integer32 0..99  

pktSwchHdlcRedialTimeoutS 1.3.6.1.4.1.164.8.5.1.1.4
The time interval in seconds between two consecutive connect operations retries.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchHdlcRedialRetriesS 1.3.6.1.4.1.164.8.5.1.1.5
This defines how many times the call operation is repeated if the call request has failed.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchHdlcInactivityS 1.3.6.1.4.1.164.8.5.1.1.6
The amount of time in minutes of inactivity that will cause the session to disconnect.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchHdlcX25FacilitiesS 1.3.6.1.4.1.164.8.5.1.1.7
This specifies the X.25 facilities. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Packet size negotiation 2 Window size negotiation 4 Reverse charge.
OBJECT-TYPE    
  Integer32 0..7  

pktSwchHdlcLocalSubaddr1S 1.3.6.1.4.1.164.8.5.1.1.8
The first local subaddress.
OBJECT-TYPE    
  Integer32 0..99  

pktSwchHdlcLocalSubaddr2S 1.3.6.1.4.1.164.8.5.1.1.9
The secondary local subaddress.
OBJECT-TYPE    
  Integer32 0..99  

pktSwchHdlcDestDlciS 1.3.6.1.4.1.164.8.5.1.1.10
The local DLCI which is used for HDLC encapsulation over Frame Relay. Range: 16...991
OBJECT-TYPE    
  Integer32  

pktSwchHdlcDestPortS 1.3.6.1.4.1.164.8.5.1.1.11
The local port that is used for HDLC encapsulation over Frame Relay. Range: 1...12
OBJECT-TYPE    
  Integer32  

pktSwchHdlcProtocolS 1.3.6.1.4.1.164.8.5.1.1.12
The HDLC protocol type.
OBJECT-TYPE    
  INTEGER hdlcOverX25(1), hdlcOverFrRel(2), hdlcOverMpe(3), hdlcReg(4), hdlcOverIp(5)  

pktSwchHdlcFlowContOptionsS 1.3.6.1.4.1.164.8.5.1.1.13
This specifies the type of flow control of the HDLC link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No flow control 1 CTS flow control 2 Clock flow control.
OBJECT-TYPE    
  Integer32 0..3  

pktSwchHdlcBufferFlowControlS 1.3.6.1.4.1.164.8.5.1.1.14
The number of buffers that will be allocated for the HDLC link. Default value is 10
OBJECT-TYPE    
  Integer32 1..200  

pktSwchHdlcInternalClockS 1.3.6.1.4.1.164.8.5.1.1.15
The baud rate of the internal clock.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r504Kbps(13), r768Kbps(14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255)  

pktSwchHdlcNrzModeS 1.3.6.1.4.1.164.8.5.1.1.16
The data encoding format. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 NRZ 1 NRZI 2 Transmit Idles between frames and control the RTS pin 4 Normal Operation (DCD, CTS lines under automatic control) XX Any combination of the values specified above.
OBJECT-TYPE    
  Integer32 0..7  

pktSwchHdlcATable 1.3.6.1.4.1.164.8.5.2
The Active Hdlc Table contains active configuration information for HDLC links
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchHdlcAEntry

pktSwchHdlcAEntry 1.3.6.1.4.1.164.8.5.2.1
Defines the contents of each line in the RAD Hdlc Table.
OBJECT-TYPE    
  PktSwchHdlcAEntry  

pktSwchHdlcLinkNumberA 1.3.6.1.4.1.164.8.5.2.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is HDLC.
OBJECT-TYPE    
  Integer32  

pktSwchHdlcDestAddrA 1.3.6.1.4.1.164.8.5.2.1.2
The destination address. It defines the X.25 address on the remote device.
OBJECT-TYPE    
  DisplayString  

pktSwchHdlcDestSubAddrA 1.3.6.1.4.1.164.8.5.2.1.3
The destination subaddress. It defines the synchronous link subaddress on the remote device.
OBJECT-TYPE    
  Integer32 0..99  

pktSwchHdlcRedialTimeoutA 1.3.6.1.4.1.164.8.5.2.1.4
The time interval in seconds between two consecutive connect operations retries.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchHdlcRedialRetriesA 1.3.6.1.4.1.164.8.5.2.1.5
This defines how many times the call operation is repeated if the call request has failed.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchHdlcInactivityA 1.3.6.1.4.1.164.8.5.2.1.6
The amount of time in minutes of inactivity that will cause the session to disconnect.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchHdlcX25FacilitiesA 1.3.6.1.4.1.164.8.5.2.1.7
This specifies the X.25 facilities. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Packet size negotiation 2 Window size negotiation 4 Reverse charge.
OBJECT-TYPE    
  Integer32 0..7  

pktSwchHdlcLocalSubaddr1A 1.3.6.1.4.1.164.8.5.2.1.8
The first local subaddress.
OBJECT-TYPE    
  Integer32 0..99  

pktSwchHdlcLocalSubaddr2A 1.3.6.1.4.1.164.8.5.2.1.9
The secondary local subaddress.
OBJECT-TYPE    
  Integer32 0..99  

pktSwchHdlcDestDlciA 1.3.6.1.4.1.164.8.5.2.1.10
The local DLCI which is used for HDLC encapsulation over Frame Relay.
OBJECT-TYPE    
  Integer32  

pktSwchHdlcDestPortA 1.3.6.1.4.1.164.8.5.2.1.11
The local port that is used for HDCL encapsulation over Frame Relay.
OBJECT-TYPE    
  Integer32  

pktSwchHdlcProtocolA 1.3.6.1.4.1.164.8.5.2.1.12
The HDLC protocol type.
OBJECT-TYPE    
  INTEGER hdlcOverX25(1), hdlcOverFrRel(2), hdlcOverMpe(3), hdlcReg(4), hdlcOverIp(5)  

pktSwchHdlcFlowContOptionsA 1.3.6.1.4.1.164.8.5.2.1.13
This specifies the type of flow control of the HDLC link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No flow control 1 CTS flow control 2 Clock flow control.
OBJECT-TYPE    
  Integer32 0..3  

pktSwchHdlcBufferFlowControlA 1.3.6.1.4.1.164.8.5.2.1.14
The number of buffers that will be allocated for the HDLC link.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchHdlcInternalClockA 1.3.6.1.4.1.164.8.5.2.1.15
The baud rate of the internal clock.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r504Kbps(13), r768Kbps(14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255)  

pktSwchHdlcNrzModeA 1.3.6.1.4.1.164.8.5.2.1.16
The data encoding format. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 NRZ 1 NRZI 2 Transmit Idles between frames and control the RTS pin 4 Normal Operation (DCD, CTS lines under automatic control) XX Any combination of the values specified above.
OBJECT-TYPE    
  Integer32 0..7  

pktSwchHdlcConnStatus 1.3.6.1.4.1.164.8.5.2.1.17
The status of the Hdlc session.
OBJECT-TYPE    
  INTEGER disconnect(1), connect(2), pvc(3)  

pktSwchHdlcSpecialStatus 1.3.6.1.4.1.164.8.5.2.1.18
The status of the Hdlc link.
OBJECT-TYPE    
  INTEGER busy(1), overflow(2), noStatus(255)  

pktSwchHdlcCtsStatus 1.3.6.1.4.1.164.8.5.2.1.19
The CTS status.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

pktSwchHdlcRunningX25Lcn 1.3.6.1.4.1.164.8.5.2.1.20
The format of the string is ifIndex:LCN
OBJECT-TYPE    
  DisplayString  

pktSwchHdlcRunningDlci 1.3.6.1.4.1.164.8.5.2.1.21
The format of the string is ifIndex:DLCI
OBJECT-TYPE    
  DisplayString  

pktSwchHdlcMaxBuffToNet 1.3.6.1.4.1.164.8.5.2.1.22
The maximum number of buffers above which Flow Control is enabled
OBJECT-TYPE    
  Integer32  

pktSwchHdlcBuffToNet 1.3.6.1.4.1.164.8.5.2.1.23
The number of buffers waiting for transmission.
OBJECT-TYPE    
  Integer32  

pktSwchStmTable 1.3.6.1.4.1.164.8.7
The STM table contains information for STM links
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchStmEntry

pktSwchStmEntry 1.3.6.1.4.1.164.8.7.1
Defines the contents of each line in the RAD STM Table.
OBJECT-TYPE    
  PktSwchStmEntry  

pktSwchStmLinkNumber 1.3.6.1.4.1.164.8.7.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link whose pktSwchPhyInterfaceProtocol is STM 4, 8, 16, or 24.
OBJECT-TYPE    
  Integer32  

pktSwchStmInternalClockS 1.3.6.1.4.1.164.8.7.1.2
The baud rate of the internal clock.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r504Kbps(13), r768Kbps(14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255)  

pktSwchStmInternalClockA 1.3.6.1.4.1.164.8.7.1.3
The current baud rate of the internal clock.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r504Kbps(13), r768Kbps(14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255)  

pktSwchStmConn 1.3.6.1.4.1.164.8.7.1.4
The connectivity status of the STM interface.
OBJECT-TYPE    
  INTEGER disconnect(1), connect(2)  

pktSwchStmSyncLoss 1.3.6.1.4.1.164.8.7.1.5
The counter for sync loss.
OBJECT-TYPE    
  Counter32  

pktSwchFr 1.3.6.1.4.1.164.8.8
OBJECT IDENTIFIER    

pktSwchFrTotFunnels 1.3.6.1.4.1.164.8.8.1
The total number of Funnels on the PS.
OBJECT-TYPE    
  Integer32  

pktSwchFrSTable 1.3.6.1.4.1.164.8.8.2
The Frame Relay Scratch Table includes the scratch values of configurable objects provided by the PS that are not included in RFC 1315.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchFrSEntry

pktSwchFrSEntry 1.3.6.1.4.1.164.8.8.2.1
Defines the contents of each line in the RAD PS Frame Relay Scratch Table.
OBJECT-TYPE    
  PktSwchFrSEntry  

pktSwchFrIfIndexS 1.3.6.1.4.1.164.8.8.2.1.1
This is the ifIndex of the frame relay port.
OBJECT-TYPE    
  Integer32  

pktSwchFrMaintProtS 1.3.6.1.4.1.164.8.8.2.1.2
This defines what maintenance protocol is running over this port. 0 - No maintenance protocol. 1 - ANSI PVC maintenance protocol running on DLCI number 0. 2 - LMI maintenance protocol running on DLCI number 1023. 4 - ITU Q.933 ANNEX A maintenance protocol running on DLCI number 0. 8 - Consolidate Link Layer Management CLLM running on DLCI number 1023. 8 cannot be a choice by itself, it can only be as part of the combination 9, 10, 12. XXX - The combination of 9, 10, 12.
OBJECT-TYPE    
  Integer32 0..12  

pktSwchFrMaintModeS 1.3.6.1.4.1.164.8.8.2.1.3
This defines the mode of maintenance protocol running over this port.
OBJECT-TYPE    
  INTEGER user(1), network(2), both(3)  

pktSwchFrRxPoolRedLineS 1.3.6.1.4.1.164.8.8.2.1.4
When the number of empty receive buffers at the port reaches this figure (of frames),the port receiver is congested. This field value should be less than the Rx pool OK field.
OBJECT-TYPE    
  Integer32 0..39  

pktSwchFrRxPoolOkS 1.3.6.1.4.1.164.8.8.2.1.5
Clear the receive congestion condition when the number of empty receive buffers at the port reaches this figure. This value (of frames) should be greater than the Rx pool red line.
OBJECT-TYPE    
  Integer32 1..40  

pktSwchFrTxPoolRedLineS 1.3.6.1.4.1.164.8.8.2.1.6
When the number of frames awaiting transmission reaches this figure, the port transmitter is congested. This field value should be greater than the Tx pool OK field.
OBJECT-TYPE    
  Integer32 1..500  

pktSwchFrTxPoolOkS 1.3.6.1.4.1.164.8.8.2.1.7
Clear the transmit congestion condition when the number of frames awaiting transmission at the port reaches this figure. This value (of frames) should be less than the Tx pool red line.
OBJECT-TYPE    
  Integer32 0..499  

pktSwchFrTxCeilingS 1.3.6.1.4.1.164.8.8.2.1.8
The maximum allowable transmit pool for this port.
OBJECT-TYPE    
  Integer32 1..500  

pktSwchFrInternalClockS 1.3.6.1.4.1.164.8.8.2.1.9
The baud rate of the internal clock.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r504Kbps(13), r768Kbps(14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255)  

pktSwchFrNrzModeS 1.3.6.1.4.1.164.8.8.2.1.10
The data encoding format.
OBJECT-TYPE    
  INTEGER nrz(1), nrzi(2)  

pktSwchFrDlciHeaderModeS 1.3.6.1.4.1.164.8.8.2.1.11
Dlci Header length for this FR port. Option 4 means that there will be no management Dlci in the range of 1024 to 8388607. The management Dlci will be in the range of 0-15 or 991-1023. Default value: 1.
OBJECT-TYPE    
  INTEGER two-octets(1), three-octets(2), four-octets(3), four-octets-nomanag(4)  

pktSwchFrDcdLinkFailureS 1.3.6.1.4.1.164.8.8.2.1.12
Link Failure Detection by DCD. If Link Failure detection by DCD is on - (3), when the DCD is down, the FR SW will detect it and change the FR link status from UP to DOWN. A trap of LINK DOWN will be sent to the NMS. Default: (2).
OBJECT-TYPE    
  INTEGER no-Detect(2), linkFailure-Detect(3)  

pktSwchFrTxIdlesS 1.3.6.1.4.1.164.8.8.2.1.13
This parameter shows whether the PS will Transmit Idles between frames and control the RTS pin. Default: no(2).
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

pktSwchFrOperationModeS 1.3.6.1.4.1.164.8.8.2.1.14
When H/W Control is configured, the SCC H/W will detect the change in the DCD or CTS signals and Start or Stop transmission automatically. When S/W Control is configured the S/W will decide when to start or stop the transmission. Default: swControl(2).
OBJECT-TYPE    
  INTEGER swControl(2), hwControl(3)  

pktSwchFrPhysInterfOptionsS 1.3.6.1.4.1.164.8.8.2.1.15
This is the physical interface. Note that the DDS physical interface H/W does not exist in the FPS-8. It is relevant for other PS devices only. For FPS-8 only the default (noOption) should be used. Default: (2).
OBJECT-TYPE    
  INTEGER noOption(2), dds4800bps(3), dds9600bps(4), dds19200bps(5), dds56000bos(6)  

pktSwchFrATable 1.3.6.1.4.1.164.8.8.3
The Frame Relay Active Table includes statistics and the active values of configurable objects provided by the PS that are not included in RFC 1315.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchFrAEntry

pktSwchFrAEntry 1.3.6.1.4.1.164.8.8.3.1
Defines the contents of each line in the RAD PS Frame Relay Active Table.
OBJECT-TYPE    
  PktSwchFrAEntry  

pktSwchFrIfIndexA 1.3.6.1.4.1.164.8.8.3.1.1
This is the ifIndex of the frame relay port.
OBJECT-TYPE    
  Integer32  

pktSwchFrMaintProtA 1.3.6.1.4.1.164.8.8.3.1.2
This defines what maintenance protocol is running over this port. 0 - No maintenance protocol. 1 - ANSI PVC maintenance protocol running on DLCI number 0. 2 - LMI maintenance protocol running on DLCI number 1023. 4 - ITU Q.933 ANNEX A maintenance protocol running on DLCI number 0. 8 - Consolidate Link Layer Management CLLM running on DLCI number 1023. 8 cannot be a choice by itself, it can only be as part of the combination 9, 10, 12. XXX - The combination of 9, 10, 12.
OBJECT-TYPE    
  Integer32 0..12  

pktSwchFrMaintModeA 1.3.6.1.4.1.164.8.8.3.1.3
This defines the mode of maintenance protocol running over this port.
OBJECT-TYPE    
  INTEGER user(1), network(2), both(3)  

pktSwchFrRxPoolRedLineA 1.3.6.1.4.1.164.8.8.3.1.4
When the number of empty receive buffers at the port reaches this figure (of frames), the port receiver is congested. This field value should be less than the Rx pool OK field.
OBJECT-TYPE    
  Integer32 0..39  

pktSwchFrRxPoolOkA 1.3.6.1.4.1.164.8.8.3.1.5
Clear the receive congestion condition when the number of empty receive buffers at the port reaches this figure. This value (of frames) should be greater than the Rx pool red line.
OBJECT-TYPE    
  Integer32 1..40  

pktSwchFrTxPoolRedLineA 1.3.6.1.4.1.164.8.8.3.1.6
When the number of frames awaiting transmission reaches this figure, the port transmitter is congested. This field value should be greater than the Tx pool OK field.
OBJECT-TYPE    
  Integer32 1..500  

pktSwchFrTxPoolOkA 1.3.6.1.4.1.164.8.8.3.1.7
Clear the transmit congestion condition when the number of frames awaiting transmission at the port reaches this figure. This value (of frames) should be less than the Tx pool red line.
OBJECT-TYPE    
  Integer32 0..499  

pktSwchFrTxCeilingA 1.3.6.1.4.1.164.8.8.3.1.8
The maximum allowable transmit pool for this port.
OBJECT-TYPE    
  Integer32 0..500  

pktSwchFrInternalClockA 1.3.6.1.4.1.164.8.8.3.1.9
The baud rate of the internal clock.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r504Kbps(13), r768Kbps(14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255)  

pktSwchFrNrzModeA 1.3.6.1.4.1.164.8.8.3.1.10
The data encoding format.
OBJECT-TYPE    
  INTEGER nrz(1), nrzi(2)  

pktSwchFrDlcmiPollingInterval 1.3.6.1.4.1.164.8.8.3.1.11
This is the number of seconds between succes- sive status enquiry messages.
OBJECT-TYPE    
  Integer32 5..30  

pktSwchFrDlcmiFullEnquiryInterval 1.3.6.1.4.1.164.8.8.3.1.12
Number of status enquiry intervals that pass before issuance of a full status enquiry mes- sage.
OBJECT-TYPE    
  Integer32 1..255  

pktSwchFrDlcmiErrorThreshold 1.3.6.1.4.1.164.8.8.3.1.13
This is the maximum number of unanswered Status Enquiries the equipment shall accept be- fore declaring the interface down.
OBJECT-TYPE    
  Integer32 1..10  

pktSwchFrDlcmiMonitoredEvents 1.3.6.1.4.1.164.8.8.3.1.14
This is the number of status polling intervals over which the error threshold is counted. For example, if within 'MonitoredEvents' number of events the station receives 'ErrorThreshold' number of errors, the interface is marked as down.
OBJECT-TYPE    
  Integer32 1..10  

pktSwchFrDlciHeaderModeA 1.3.6.1.4.1.164.8.8.3.1.15
Dlci Header length for this FR port. Option 4 means that there will be no management Dlci in the range of 1024 to 8388607. The management Dlci will be in the range of 0-15 or 991-1023. Default value: 1.
OBJECT-TYPE    
  INTEGER two-octets(1), three-octets(2), four-octets(3), four-octets-nomanag(4)  

pktSwchFrDcdLinkFailureA 1.3.6.1.4.1.164.8.8.3.1.16
Link Failure Detection by DCD. If Link Failure detection by DCD is on - (3), when the DCD is down, the FR SW will detect it and change the FR link status from UP to DOWN. A trap of LINK DOWN will be sent to the NMS. Default: (2).
OBJECT-TYPE    
  INTEGER no-Detect(2), linkFailure-Detect(3)  

pktSwchFrTxIdlesA 1.3.6.1.4.1.164.8.8.3.1.17
This parameter shows whether the PS will Transmit Idles between frames and control the RTS pin. Default: no(2).
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

pktSwchFrOperationModeA 1.3.6.1.4.1.164.8.8.3.1.18
When H/W Control is configured, the SCC H/W will detect the change in the DCD or CTS signals and Start or Stop transmission automatically. When S/W Control is configured the S/W will decide when to start or stop the transmission. Default: swControl(2).
OBJECT-TYPE    
  INTEGER swControl(2), hwControl(3)  

pktSwchFrPhysInterfOptionsA 1.3.6.1.4.1.164.8.8.3.1.19
This is the physical interface. Note that the DDS physical interface H/W does not exist in the FPS-8. It is relevant for other PS devices only. For FPS-8 only the default (noOption) should be used. Default: (2).
OBJECT-TYPE    
  INTEGER noOption(2), dds4800bps(3), dds9600bps(4), dds19200bps(5), dds56000bos(6)  

pktSwchFrIfTable 1.3.6.1.4.1.164.8.8.4
The Frame Relay Active Port Table includes statistics and configurable objects provided by the PS that are not included in RFC 1315.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchFrIfEntry

pktSwchFrIfEntry 1.3.6.1.4.1.164.8.8.4.1
Defines the contents of each line in the RAD PS Frame Relay Port Active Table.
OBJECT-TYPE    
  PktSwchFrIfEntry  

pktSwchFrIfTxBytes 1.3.6.1.4.1.164.8.8.4.1.1
The number of Tx bytes.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfRxBytes 1.3.6.1.4.1.164.8.8.4.1.2
The number of Rx bytes.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfTxCongDiscards 1.3.6.1.4.1.164.8.8.4.1.3
The number of frames discarded because of Tx congestion.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfDeTxFrames 1.3.6.1.4.1.164.8.8.4.1.4
The number of DE Tx frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfDeRxFrames 1.3.6.1.4.1.164.8.8.4.1.5
The number of DE Rx frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfFecnTxFrames 1.3.6.1.4.1.164.8.8.4.1.6
The number of FECN Tx frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfFecnRxFrames 1.3.6.1.4.1.164.8.8.4.1.7
The number of FECN Tx frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfBecnTxFrames 1.3.6.1.4.1.164.8.8.4.1.8
The number of BECN Tx frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfBecnRxFrames 1.3.6.1.4.1.164.8.8.4.1.9
The number of BECN Tx frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfCommRateViolTxFrames 1.3.6.1.4.1.164.8.8.4.1.10
The number of Tx committed rate violations in number of frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfCommRateViolRxFrames 1.3.6.1.4.1.164.8.8.4.1.11
The number of Rx committed rate violations in number of frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfExcessRateViolTxFrames 1.3.6.1.4.1.164.8.8.4.1.12
The number of Tx excess rate violations in number of frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfExcessRateViolRxFrames 1.3.6.1.4.1.164.8.8.4.1.13
The number of Rx excess rate violations in number of frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfBuffersInTxPool 1.3.6.1.4.1.164.8.8.4.1.14
The number of buffers waiting for transmission.
OBJECT-TYPE    
  Integer32  

pktSwchFrIfFreeBuffersInRxPool 1.3.6.1.4.1.164.8.8.4.1.15
The number of free buffers in the Rx pool.
OBJECT-TYPE    
  Integer32  

pktSwchFrIfLmiTxFrames 1.3.6.1.4.1.164.8.8.4.1.16
The number of LMI Tx Frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfLmiRxFrames 1.3.6.1.4.1.164.8.8.4.1.17
The number of LMI Rx Frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfAnsiTxFrames 1.3.6.1.4.1.164.8.8.4.1.18
The number of ANSI Tx Frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfAnsiRxFrames 1.3.6.1.4.1.164.8.8.4.1.19
The number of ANSI Rx Frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfCllmTxFrames 1.3.6.1.4.1.164.8.8.4.1.20
The number of CLLM Tx Frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfCllmRxFrames 1.3.6.1.4.1.164.8.8.4.1.21
The number of CLLM Rx Frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfTxCongestions 1.3.6.1.4.1.164.8.8.4.1.22
The number of Tx congestions.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfRxCongestions 1.3.6.1.4.1.164.8.8.4.1.23
The number of Rx congestions.
OBJECT-TYPE    
  Counter32  

pktSwchFrIfTotDlciNumber 1.3.6.1.4.1.164.8.8.4.1.24
The total number of DLCIs defined.
OBJECT-TYPE    
  Integer32  

pktSwchFrCircuitSTable 1.3.6.1.4.1.164.8.8.5
The Frame Relay Scratch Circuit Table includes configurable objects provided by the PS that are not included in RFC 1315.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchFrCircuitSEntry

pktSwchFrCircuitSEntry 1.3.6.1.4.1.164.8.8.5.1
Defines the contents of each line in the RAD PS Frame Relay Circuit Scratch Table.
OBJECT-TYPE    
  PktSwchFrCircuitSEntry  

pktSwchFrCircuitIfIndexS 1.3.6.1.4.1.164.8.8.5.1.1
This is the ifIndex of the circuit, according to RFC 1573.
OBJECT-TYPE    
  Integer32  

pktSwchFrCircuitIndexS 1.3.6.1.4.1.164.8.8.5.1.2
This Index is the DLCI of the circuit.
OBJECT-TYPE    
  Integer32  

pktSwchFrCircuitDestProtS 1.3.6.1.4.1.164.8.8.5.1.3
The protocol encapsulation, if any, on this DLCI. The MPE protocol is a proprietary RAD protocol that enables a generic HDLC device to have multiple connections over X.25 or Frame Relay.
OBJECT-TYPE    
  INTEGER x25(1), none(2), hdlc(3), async(4), multiPoint(5), rfc1490(6)  

pktSwchFrCircuitDestIdS 1.3.6.1.4.1.164.8.8.5.1.4
If the DLCI destination protocol is none or async, this field has a value of an existing DLCI or async channel, respectively. Otherwise, a value of zero is used.
OBJECT-TYPE    
  DisplayString  

pktSwchFrCircuitBackIdS 1.3.6.1.4.1.164.8.8.5.1.5
The backup DLCI which is used when the current DLCI goes inactive. The destination protocol and destination id are the same as in the current DLCI
OBJECT-TYPE    
  DisplayString  

pktSwchFrCircuitTxCirIntervalS 1.3.6.1.4.1.164.8.8.5.1.6
The Tx CIR interval in 1/10 seconds.
OBJECT-TYPE    
  Integer32 0..10  

pktSwchFrCircuitTxCommittedS 1.3.6.1.4.1.164.8.8.5.1.7
The Tx committed rate in bytes per interval.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrCircuitTxExcessS 1.3.6.1.4.1.164.8.8.5.1.8
The Tx excess in bytes per interval.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrCircuitRxCirIntervalS 1.3.6.1.4.1.164.8.8.5.1.9
The Rx CIR interval in 1/10 seconds.
OBJECT-TYPE    
  Integer32 0..10  

pktSwchFrCircuitRxCommittedS 1.3.6.1.4.1.164.8.8.5.1.10
The Rx committed rate in bytes per interval.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrCircuitRxExcessS 1.3.6.1.4.1.164.8.8.5.1.11
The Rx excess in bytes per interval.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrCircuitFunnelIdS 1.3.6.1.4.1.164.8.8.5.1.12
The funnel ID.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchFrCircuitStatusS 1.3.6.1.4.1.164.8.8.5.1.13
The status of the circuit row in the Table.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchFrCircuitExtendedDlciS 1.3.6.1.4.1.164.8.8.5.1.14
The no. of the DLCI represented in 23 bits.
OBJECT-TYPE    
  Integer32 0..8388607  

pktSwchFrCircuitTxPriorityS 1.3.6.1.4.1.164.8.8.5.1.15
DLCI TX Priority level. The levels are defined in the pktSwchTxPriorityTable
OBJECT-TYPE    
  Integer32 1..4  

pktSwchFrCircuitIsdnRoutIdS 1.3.6.1.4.1.164.8.8.5.1.16
ISDN destination. ID in the ISDN routing table containing the outgoing ISDN address for this DLCI. Default value: 0 for no ISDN routing ID.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchFrCircuitATable 1.3.6.1.4.1.164.8.8.6
The Frame Relay Active Circuit Table includes statistics and configurable objects provided by the PS that are not included in RFC 1315.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchFrCircuitAEntry

pktSwchFrCircuitAEntry 1.3.6.1.4.1.164.8.8.6.1
Defines the contents of each line in the RAD PS Frame Relay Circuit Active Table.
OBJECT-TYPE    
  PktSwchFrCircuitAEntry  

pktSwchFrCircuitIfIndexA 1.3.6.1.4.1.164.8.8.6.1.1
This is the ifIndex of the circuit, according to RFC 1573.
OBJECT-TYPE    
  Integer32  

pktSwchFrCircuitIndexA 1.3.6.1.4.1.164.8.8.6.1.2
This Index is the DLCI of the circuit.
OBJECT-TYPE    
  Integer32  

pktSwchFrCircuitDestProtA 1.3.6.1.4.1.164.8.8.6.1.3
The protocol encapsulation, if any, on this DLCI. The MPE protocol is a proprietary RAD protocol that enables a generic HDLC device to have multiple connections over X.25 or Frame Relay.
OBJECT-TYPE    
  INTEGER x25(1), none(2), hdlc(3), async(4), multiPoint(5), rfc1490(6)  

pktSwchFrCircuitDestIdA 1.3.6.1.4.1.164.8.8.6.1.4
If the DLCI destination protocol is none or async, this field has a value of an existing DLCI or async channel, respectively. Otherwise, a value of zero is used.
OBJECT-TYPE    
  DisplayString  

pktSwchFrCircuitBackIdA 1.3.6.1.4.1.164.8.8.6.1.5
The backup DLCI which is used when the current DLCI goes inactive. The destination protocol and destination id are the same as in the current DLCI
OBJECT-TYPE    
  DisplayString  

pktSwchFrCircuitTxCirIntervalA 1.3.6.1.4.1.164.8.8.6.1.6
The Tx CIR interval in 1/10 seconds.
OBJECT-TYPE    
  Integer32 0..10  

pktSwchFrCircuitTxCommittedA 1.3.6.1.4.1.164.8.8.6.1.7
The Tx committed rate in bytes per interval.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrCircuitTxExcessA 1.3.6.1.4.1.164.8.8.6.1.8
The Tx excess in bytes per interval.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrCircuitRxCirIntervalA 1.3.6.1.4.1.164.8.8.6.1.9
The Rx CIR interval in 1/10 seconds.
OBJECT-TYPE    
  Integer32 0..10  

pktSwchFrCircuitRxCommittedA 1.3.6.1.4.1.164.8.8.6.1.10
The Rx committed rate in bytes per interval.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrCircuitRxExcessA 1.3.6.1.4.1.164.8.8.6.1.11
The Rx excess in bytes per interval.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrCircuitFunnelIdA 1.3.6.1.4.1.164.8.8.6.1.12
The funnel ID.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchFrCircuitFunnelStat 1.3.6.1.4.1.164.8.8.6.1.13
The funnel status.
OBJECT-TYPE    
  DisplayString  

pktSwchFrCircuitTxCongDiscards 1.3.6.1.4.1.164.8.8.6.1.14
The number of frames discarded because of Tx congestion.
OBJECT-TYPE    
  Counter32  

pktSwchFrCircuitDeTxFrames 1.3.6.1.4.1.164.8.8.6.1.15
The number of DE Tx frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrCircuitDeRxFrames 1.3.6.1.4.1.164.8.8.6.1.16
The number of DE Rx frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrCircuitFecnTxFrames 1.3.6.1.4.1.164.8.8.6.1.17
The number of FECN Tx frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrCircuitBecnTxFrames 1.3.6.1.4.1.164.8.8.6.1.18
The number of BECN Tx frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrCircuitCommRateViolTxFrames 1.3.6.1.4.1.164.8.8.6.1.19
The number of Tx committed rate violations in number of frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrCircuitCommRateViolRxFrames 1.3.6.1.4.1.164.8.8.6.1.20
The number of Rx committed rate violations in number of frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrCircuitExcessRateViolTxFrames 1.3.6.1.4.1.164.8.8.6.1.21
The number of Tx excess rate violations in number of frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrCircuitExcessRateViolRxFrames 1.3.6.1.4.1.164.8.8.6.1.22
The number of Rx excess rate violations in number of frames.
OBJECT-TYPE    
  Counter32  

pktSwchFrCircuitState 1.3.6.1.4.1.164.8.8.6.1.23
Indicates whether the particular virtual cir- cuit is new or not.
OBJECT-TYPE    
  INTEGER new(1), noState(2)  

pktSwchFrCircuitExtendedDlciA 1.3.6.1.4.1.164.8.8.6.1.24
The no. of the DLCI represented in 23 bits.
OBJECT-TYPE    
  Integer32 0..8388607  

pktSwchFrCircuitTxPriorityA 1.3.6.1.4.1.164.8.8.6.1.25
DLCI TX Priority level. The levels are defined in the pktSwchTxPriorityTable
OBJECT-TYPE    
  Integer32 1..4  

pktSwchFrCircuitIsdnRoutIdA 1.3.6.1.4.1.164.8.8.6.1.26
ISDN destination. ID in the ISDN routing table containing the outgoing ISDN address for this DLCI. Default value: 0 for no ISDN routing ID.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchFrFunnelSTable 1.3.6.1.4.1.164.8.8.7
The Frame Relay Funnel Table defines the funnels that DLCIs may use.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchFrFunnelSEntry

pktSwchFrFunnelSEntry 1.3.6.1.4.1.164.8.8.7.1
Defines the contents of each line in the RAD PS Frame Relay Funnel Table.
OBJECT-TYPE    
  PktSwchFrFunnelSEntry  

pktSwchFrFunnelIndexS 1.3.6.1.4.1.164.8.8.7.1.1
This is the index of the funnel table.
OBJECT-TYPE    
  Integer32  

pktSwchFrFunnelSizeS 1.3.6.1.4.1.164.8.8.7.1.2
The number of frames the funnel can store internally, where each frame is 512 bytes.
OBJECT-TYPE    
  Integer32 0..256  

pktSwchFrFunnelHighWaterFramesS 1.3.6.1.4.1.164.8.8.7.1.3
The maximum number of frames the funnel can hold before it expands and transmits all the data.
OBJECT-TYPE    
  Integer32 0..256  

pktSwchFrFunnelHighWaterBytesS 1.3.6.1.4.1.164.8.8.7.1.4
The maximum number of bytes the funnel can hold before it expands and transmits all the data.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrFunnelGaugeTxRateS 1.3.6.1.4.1.164.8.8.7.1.5
The outgoing data rate in bytes per window of the funnel.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrFunnelTransWindowS 1.3.6.1.4.1.164.8.8.7.1.6
The transmission rate is measured during a sliding time window. This parameter defines the window in 1/10 seconds.
OBJECT-TYPE    
  Integer32 0..10  

pktSwchFrFunnelStatusS 1.3.6.1.4.1.164.8.8.7.1.7
The status of this funnel table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchFrFunnelATable 1.3.6.1.4.1.164.8.8.8
The Frame Relay Funnel Table defines the funnels that DLCIs may use.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchFrFunnelAEntry

pktSwchFrFunnelAEntry 1.3.6.1.4.1.164.8.8.8.1
Defines the contents of each line in the RAD PS Frame Relay Funnel Table.
OBJECT-TYPE    
  PktSwchFrFunnelAEntry  

pktSwchFrFunnelIndexA 1.3.6.1.4.1.164.8.8.8.1.1
This is the index of the funnel table.
OBJECT-TYPE    
  Integer32  

pktSwchFrFunnelSizeA 1.3.6.1.4.1.164.8.8.8.1.2
The number of frames the funnel can store internally, where each frame is 512 bytes.
OBJECT-TYPE    
  Integer32 0..256  

pktSwchFrFunnelHighWaterFramesA 1.3.6.1.4.1.164.8.8.8.1.3
The maximum number of frames the funnel can hold before it expands and transmits all the data.
OBJECT-TYPE    
  Integer32 0..256  

pktSwchFrFunnelHighWaterBytesA 1.3.6.1.4.1.164.8.8.8.1.4
The maximum number of bytes the funnel can hold before it expands and transmits all the data.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrFunnelGaugeTxRateA 1.3.6.1.4.1.164.8.8.8.1.5
The outgoing data rate in bytes per window of the funnel.
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchFrFunnelTransWindowA 1.3.6.1.4.1.164.8.8.8.1.6
The transmission rate is measured during a sliding time window. This parameter defines the window in 1/10 seconds.
OBJECT-TYPE    
  Integer32 0..10  

pktSwchFrDlciMapTable 1.3.6.1.4.1.164.8.8.9
The Frame Relay Dlci mapping Table maps the Dlci numbers. For each long Dlci a short one is mapped. A long Dlci is a Dlci which contains a Dlci header of 3 or 4 bytes instead of the regular 2 bytes. The long Dlci number has values from 1024 to 8,388,607.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchFrDlciMapEntry

pktSwchFrDlciMapEntry 1.3.6.1.4.1.164.8.8.9.1
Defines the contents of each Dlci Map Table entry.
OBJECT-TYPE    
  PktSwchFrDlciMapEntry  

pktSwchFrDlciMapPort 1.3.6.1.4.1.164.8.8.9.1.1
Frame Relay port no. : 1-8 for FPS-8, 1-4 for FPS-4, 1-3 for APS, 1-6 for SPS-6, 1-12 for SPS-12.
OBJECT-TYPE    
  Integer32  

pktSwchFrDlciMapLongDlci 1.3.6.1.4.1.164.8.8.9.1.2
The Long Dlci number. For Dlci's of 4 octets, the long Dlci number has values from 1024 to 8,388,607. For Dlci's of 2 octets, the long Dlci number has values of 16-991.
OBJECT-TYPE    
  Integer32 0..8388607  

pktSwchFrDlciMapShortDlci 1.3.6.1.4.1.164.8.8.9.1.3
The Short Dlci number. Legal values: 0 - 1023.
OBJECT-TYPE    
  Integer32 0..1023  

pktSwchFrDlciMapStatus 1.3.6.1.4.1.164.8.8.9.1.4
The status of the map row in the Table. The only value which can be set is: createRequest. This value is set when a new long dlci is created.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchMpe 1.3.6.1.4.1.164.8.9
OBJECT IDENTIFIER    

pktSwchMpeSTable 1.3.6.1.4.1.164.8.9.1
The MPE Table defines Scratch configuration parameters for the MPE protocol.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchMpeSEntry

pktSwchMpeSEntry 1.3.6.1.4.1.164.8.9.1.1
Defines the contents of each line in the MPE Table.
OBJECT-TYPE    
  PktSwchMpeSEntry  

pktSwchMpeLinkNumberS 1.3.6.1.4.1.164.8.9.1.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is MPE.
OBJECT-TYPE    
  Integer32  

pktSwchMpeInactivityS 1.3.6.1.4.1.164.8.9.1.1.2
The amount of time in minutes of inactivity that will cause the session to disconnect.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchMpeX25FacilitiesS 1.3.6.1.4.1.164.8.9.1.1.3
This specifies the X.25 facilities. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Packet size negotiation 2 Window size negotiation 4 Reverse charge.
OBJECT-TYPE    
  Integer32 0..7  

pktSwchMpeLocSubAddr1S 1.3.6.1.4.1.164.8.9.1.1.4
The first local subaddress.
OBJECT-TYPE    
  Integer32 1..99  

pktSwchMpeLocSubAddr2S 1.3.6.1.4.1.164.8.9.1.1.5
The second local subaddress.
OBJECT-TYPE    
  Integer32 1..99  

pktSwchMpeFlwCtrlDurS 1.3.6.1.4.1.164.8.9.1.1.6
The duration in 50 milliseconds of a hardware flow control signal. Default is 0
OBJECT-TYPE    
  Integer32 0..200  

pktSwchMpeFlwCtrlOptS 1.3.6.1.4.1.164.8.9.1.1.7
This specifies the type of flow control of the MPE link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No flow control 1 CTS flow control 2 Clock flow control.
OBJECT-TYPE    
  Integer32 0..3  

pktSwchMpeFlwCtrlBufS 1.3.6.1.4.1.164.8.9.1.1.8
The number of buffers that will be allocated for the MPE link.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchMpeInternalClkS 1.3.6.1.4.1.164.8.9.1.1.9
The baud rate of the internal clock.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r504Kbps(13), r768Kbps(14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255)  

pktSwchMpeATable 1.3.6.1.4.1.164.8.9.2
The MPE Table defines Active configuration parameters for the MPE protocol.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchMpeAEntry

pktSwchMpeAEntry 1.3.6.1.4.1.164.8.9.2.1
Defines the contents of each line in the MPE Table.
OBJECT-TYPE    
  PktSwchMpeAEntry  

pktSwchMpeLinkNumberA 1.3.6.1.4.1.164.8.9.2.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is MPE.
OBJECT-TYPE    
  Integer32  

pktSwchMpeInactivityA 1.3.6.1.4.1.164.8.9.2.1.2
The amount of time in minutes of inactivity that will cause the session to disconnect.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchMpeX25FacilitiesA 1.3.6.1.4.1.164.8.9.2.1.3
This specifies the X.25 facilities. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Packet size negotiation 2 Window size negotiation 4 Reverse charge.
OBJECT-TYPE    
  Integer32 0..7  

pktSwchMpeLocSubAddr1A 1.3.6.1.4.1.164.8.9.2.1.4
The first local subaddress.
OBJECT-TYPE    
  Integer32 1..99  

pktSwchMpeLocSubAddr2A 1.3.6.1.4.1.164.8.9.2.1.5
The second local subaddress.
OBJECT-TYPE    
  Integer32 1..99  

pktSwchMpeFlwCtrlDurA 1.3.6.1.4.1.164.8.9.2.1.6
The duration in 50 milliseconds of a hardware flow control signal.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchMpeFlwCtrlOptA 1.3.6.1.4.1.164.8.9.2.1.7
This specifies the type of flow control of the MPE link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No flow control 1 CTS flow control 2 Clock flow control.
OBJECT-TYPE    
  Integer32 0..3  

pktSwchMpeFlwCtrlBufA 1.3.6.1.4.1.164.8.9.2.1.8
The number of buffers that will be allocated for the MPE link.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchMpeInternalClkA 1.3.6.1.4.1.164.8.9.2.1.9
The baud rate of the internal clock.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r504Kbps(13), r768Kbps(14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255)  

pktSwchMpeCtsStatus 1.3.6.1.4.1.164.8.9.2.1.10
The CTS status.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

pktSwchMpeAidSTable 1.3.6.1.4.1.164.8.9.3
The AID Table defines Scratch configuration parameters for the logical connections (Address Id).
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchMpeAidSEntry

pktSwchMpeAidSEntry 1.3.6.1.4.1.164.8.9.3.1
Defines the contents of each line in the MPE Table.
OBJECT-TYPE    
  PktSwchMpeAidSEntry  

pktSwchMpeAddressIdS 1.3.6.1.4.1.164.8.9.3.1.1
The Address Id (AID) with which this entry is associated.
OBJECT-TYPE    
  Integer32  

pktSwchMpeAidMainTypeS 1.3.6.1.4.1.164.8.9.3.1.2
The protocol with which the AID is communicating.
OBJECT-TYPE    
  INTEGER x25Svc(1), x25Pvc(2), fr(3), innerCom(4), notActive(255)  

pktSwchMpeAidMainIdS 1.3.6.1.4.1.164.8.9.3.1.3
The link number of the protocol with which the AID is communicating. The link number of the protocol with which the AID is communicating. For X.25 SVC this number is Any Autocall ID (Pre-defined) , values: 1..200 For X.25 PVC this number is a local PVC that its source link has already been set to the current link with a prefix of N. values: 1..200 For FR this number is any Frame Relay link number (Pre-defined), values: 1..12 For Inner communication this number is an HDLC or MPE link number (Pre-defined), values: 1..12 For notActive this number is 0.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchMpeAidMainSubIdS 1.3.6.1.4.1.164.8.9.3.1.4
The DLCI with which the AID is communicating. Sub ID is used only when Type is Frame Relay or Inner Comm. The DLCI or destination AID with which the current AID is communicating. If type is: Frame Relay PVC: Sub ID must be an existing DLCI, 16-991. (The DLCI's destination protocol has to be predefined to MPE). If type is: Inner Communication: In case of an HDLC link, Sub ID must be 0. In case of an MPE link, Sub ID must be in AID permitted range. For notActive this number is 0.
OBJECT-TYPE    
  Integer32 0..991  

pktSwchMpeAidBackupTypeS 1.3.6.1.4.1.164.8.9.3.1.5
The protocol with which the AID is communicating on the backup.
OBJECT-TYPE    
  INTEGER x25Svc(1), x25Pvc(2), fr(3), innerCom(4), notActive(255)  

pktSwchMpeAidBackupIdS 1.3.6.1.4.1.164.8.9.3.1.6
The link number of the protocol with which the AID is communicating on the backup. The link number of the protocol with which the AID is communicating. For X.25 SVC this number is Any Autocall ID (Pre-defined) , values: 1..200 For X.25 PVC this number is a local PVC that its source link has already been set to the current link with a prefix of N. values: 1..200 For FR this number is any Frame Relay link number (Pre-defined), values: 1..12 For Inner communication this number is an HDLC or MPE link number (Pre-defined), values: 1..12 For notActive this number is 0.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchMpeAidBackupSubIdS 1.3.6.1.4.1.164.8.9.3.1.7
The DLCI with which the AID is communicating. Sub ID is used only when Type is Frame Relay or Inner Comm. The DLCI or destination AID with which the current AID is communicating. If type is: Frame Relay PVC: Sub ID must be an existing DLCI, 16-991. (The DLCI's destination protocol has to be predefined to MPE). If type is: Inner Communication: In case of an HDLC link, Sub ID must be 0. In case of an MPE link, Sub ID must be in AID permitted range. For notActive this number is 0.
OBJECT-TYPE    
  Integer32 0..991  

pktSwchMpeAidStatusS 1.3.6.1.4.1.164.8.9.3.1.8
The status of this Address Id table entry.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchMpeAidATable 1.3.6.1.4.1.164.8.9.4
The AID Table defines Active configuration parameters for the logical connections (Address Id).
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchMpeAidAEntry

pktSwchMpeAidAEntry 1.3.6.1.4.1.164.8.9.4.1
Defines the contents of each line in the MPE Table.
OBJECT-TYPE    
  PktSwchMpeAidAEntry  

pktSwchMpeAddressIdA 1.3.6.1.4.1.164.8.9.4.1.1
The Address Id (AID) with which this entry is associated.
OBJECT-TYPE    
  Integer32  

pktSwchMpeAidMainTypeA 1.3.6.1.4.1.164.8.9.4.1.2
The protocol with which the AID is communicating.
OBJECT-TYPE    
  INTEGER x25Svc(1), x25Pvc(2), fr(3), innerCom(4), notActive(255)  

pktSwchMpeAidMainIdA 1.3.6.1.4.1.164.8.9.4.1.3
The link number of the protocol with which the AID is communicating. The link number of the protocol with which the AID is communicating. For X.25 SVC this number is Any Autocall ID (Pre-defined) , values: 1..200 For X.25 PVC this number is a local PVC that its source link has already been set to the current link with a prefix of N. values: 1..200 For FR this number is any Frame Relay link number (Pre-defined), values: 1..12 For Inner communication this number is an HDLC or MPE link number (Pre-defined), values: 1..12 For notActive this number is 0.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchMpeAidMainSubIdA 1.3.6.1.4.1.164.8.9.4.1.4
The DLCI with which the AID is communicating. Sub ID is used only when Type is Frame Relay or Inner Comm. The DLCI or destination AID with which the current AID is communicating. If type is: Frame Relay PVC: Sub ID must be an existing DLCI, 16-991. (The DLCI's destination protocol has to be predefined to MPE). If type is: Inner Communication: In case of an HDLC link, Sub ID must be 0. In case of an MPE link, Sub ID must be in AID permitted range. For notActive this number is 0.
OBJECT-TYPE    
  Integer32 0..991  

pktSwchMpeAidBackupTypeA 1.3.6.1.4.1.164.8.9.4.1.5
The protocol with which the AID is communicating on the backup.
OBJECT-TYPE    
  INTEGER x25Svc(1), x25Pvc(2), fr(3), innerCom(4), notActive(255)  

pktSwchMpeAidBackupIdA 1.3.6.1.4.1.164.8.9.4.1.6
The link number of the protocol with which the AID is communicating on the backup. The link number of the protocol with which the AID is communicating. For X.25 SVC this number is Any Autocall ID (Pre-defined) , values: 1..200 For X.25 PVC this number is a local PVC that its source link has already been set to the current link with a prefix of N. values: 1..200 For FR this number is any Frame Relay link number (Pre-defined), values: 1..12 For Inner communication this number is an HDLC or MPE link number (Pre-defined), values: 1..12 For notActive this number is 0.
OBJECT-TYPE    
  Integer32 0..200  

pktSwchMpeAidBackupSubIdA 1.3.6.1.4.1.164.8.9.4.1.7
The DLCI with which the AID is communicating. Sub ID is used only when Type is Frame Relay or Inner Comm. The DLCI or destination AID with which the current AID is communicating. If type is: Frame Relay PVC: Sub ID must be an existing DLCI, 16-991. (The DLCI's destination protocol has to be predefined to MPE). If type is: Inner Communication: In case of an HDLC link, Sub ID must be 0. In case of an MPE link, Sub ID must be in AID permitted range. For notActive this number is 0.
OBJECT-TYPE    
  Integer32 0..991  

pktSwchMpeAidConn 1.3.6.1.4.1.164.8.9.4.1.8
The connectivity status of the AID.
OBJECT-TYPE    
  INTEGER disconnect(1), connect(2), pvc(3)  

pktSwchMpeAidFlwCtrl 1.3.6.1.4.1.164.8.9.4.1.9
The Flow Control status of the AID.
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

pktSwchSlip 1.3.6.1.4.1.164.8.10
OBJECT IDENTIFIER    

pktSwchSlipSTable 1.3.6.1.4.1.164.8.10.1
The Scratch Slip Table contains configuration information for Slip links
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSlipSEntry

pktSwchSlipSEntry 1.3.6.1.4.1.164.8.10.1.1
Defines the contents of each line in the RAD Slip Table.
OBJECT-TYPE    
  PktSwchSlipSEntry  

pktSwchSlipLinkNumberS 1.3.6.1.4.1.164.8.10.1.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceIfIndex. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is Slip.
OBJECT-TYPE    
  Integer32  

pktSwchSlipSpeedS 1.3.6.1.4.1.164.8.10.1.1.2
This parameter determines the rate of data transmission to and from the DTE.
OBJECT-TYPE    
  INTEGER s110bps(1), s300bps(2), s1200bps(3), s600bps(4), s75bps(5), s150bps(6), s2400bps(12), s4800bps(13), s9600bps(14), s19200bps(15), s38400bps(19), s57600bps(20), s115200bps(21)  

pktSwchSlipFCOptionS 1.3.6.1.4.1.164.8.10.1.1.3
The flow control options 0 - No HARDWARE flow control 1..254 - Timer value (in 50ms intervals), when timer expires, flow control stops 255 - The timer is not used
OBJECT-TYPE    
  Integer32 0..255  

pktSwchSlipStopBitsS 1.3.6.1.4.1.164.8.10.1.1.4
This entry indicates the number of stop bits per character supported by the PAD. The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits.
OBJECT-TYPE    
  INTEGER one(1), two(2), oneAndHalf(3)  

pktSwchSlipBitPerCharS 1.3.6.1.4.1.164.8.10.1.1.5
The number of data bits per character supported by the Slip link.
OBJECT-TYPE    
  Integer32 5..8  

pktSwchSlipParityS 1.3.6.1.4.1.164.8.10.1.1.6
This entry selects the type of parity to be checked and or generated by the PAD when radSPSProfileParTreat is a value other than 255. The options are (1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity.
OBJECT-TYPE    
  INTEGER space(1), mark(2), even(3), odd(4), none(255)  

pktSwchSlipIpAddressS 1.3.6.1.4.1.164.8.10.1.1.7
The IP address connected to this Slip port. This variable is used when an automatic connection is done by the IP Routing.
OBJECT-TYPE    
  IpAddress  

pktSwchSlipIpMaskS 1.3.6.1.4.1.164.8.10.1.1.8
The IP mask. This variable is used when an automatic connection by the IP Routing is done.
OBJECT-TYPE    
  IpAddress  

pktSwchSlipDefEncapsTypeS 1.3.6.1.4.1.164.8.10.1.1.9
Destination protocol of this Slip port. This variable is used when a direct connection without IP Routing is done.
OBJECT-TYPE    
  INTEGER slip(1), x25SVC(2), x25PVC(3), frameRelay(4), hdlc(5), none(255)  

pktSwchSlipDefDestinationS 1.3.6.1.4.1.164.8.10.1.1.10
Default destination for this Slip port. This variable is used when a direct connection without IP Routing is done. Possible values: Default : Not Used. X.25 PVC: Port:LCN or a pre defined PVC number X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number Frame Relay: Port:DLCI HDLC: HDLC Port Number SLIP: SLIP Channel Number
OBJECT-TYPE    
  DisplayString  

pktSwchSlipATable 1.3.6.1.4.1.164.8.10.2
The Active Slip Table contains configuration information for Slip links
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSlipAEntry

pktSwchSlipAEntry 1.3.6.1.4.1.164.8.10.2.1
Defines the contents of each line in the RAD Slip Table.
OBJECT-TYPE    
  PktSwchSlipAEntry  

pktSwchSlipLinkNumberA 1.3.6.1.4.1.164.8.10.2.1.1
The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceIfIndex. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is Slip.
OBJECT-TYPE    
  Integer32  

pktSwchSlipSpeedA 1.3.6.1.4.1.164.8.10.2.1.2
This parameter determines the rate of data transmission to and from the DTE.
OBJECT-TYPE    
  INTEGER s110bps(1), s300bps(2), s1200bps(3), s600bps(4), s75bps(5), s150bps(6), s2400bps(12), s4800bps(13), s9600bps(14), s19200bps(15), s38400bps(19), s57600bps(20), s115200bps(21)  

pktSwchSlipFCOptionA 1.3.6.1.4.1.164.8.10.2.1.3
The flow control options 0 - No HARDWARE flow control 1..254 - Timer value (in 50ms intervals), when timer expires, flow control stops 255 - The timer is not used
OBJECT-TYPE    
  Integer32 0..255  

pktSwchSlipStopBitsA 1.3.6.1.4.1.164.8.10.2.1.4
This entry indicates the number of stop bits per character supported by the PAD. The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits.
OBJECT-TYPE    
  INTEGER one(1), two(2), oneAndHalf(3)  

pktSwchSlipBitPerCharA 1.3.6.1.4.1.164.8.10.2.1.5
The number of data bits per character supported by the Slip link.
OBJECT-TYPE    
  Integer32 5..8  

pktSwchSlipParityA 1.3.6.1.4.1.164.8.10.2.1.6
This entry selects the type of parity to be checked and or generated by the PAD when radSPSProfileParTreat is a value other than 255. The options are (1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity.
OBJECT-TYPE    
  INTEGER space(1), mark(2), even(3), odd(4), none(255)  

pktSwchSlipIpAddressA 1.3.6.1.4.1.164.8.10.2.1.7
The IP address connected to this Slip port.
OBJECT-TYPE    
  IpAddress  

pktSwchSlipIpMaskA 1.3.6.1.4.1.164.8.10.2.1.8
The IP mask.
OBJECT-TYPE    
  IpAddress  

pktSwchSlipDefEncapsTypeA 1.3.6.1.4.1.164.8.10.2.1.9
Destination protocol of this Slip port.
OBJECT-TYPE    
  INTEGER slip(1), x25SVC(2), x25PVC(3), frameRelay(4), hdlc(5), none(255)  

pktSwchSlipDefDestinationA 1.3.6.1.4.1.164.8.10.2.1.10
Default destination for this Slip port. This variable is used when a direct connection without IP Routing is done. Possible values: Default : Not Used. X.25 PVC: Port:LCN or a pre defined PVC number X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number Frame Relay: Port:DLCI HDLC: HDLC Port Number SLIP: SLIP Channel Number
OBJECT-TYPE    
  DisplayString  

pktSwchSna 1.3.6.1.4.1.164.8.11
OBJECT IDENTIFIER    

pktSwchSnaSDLCLinkTableS 1.3.6.1.4.1.164.8.11.1
The SDLC Link Table defines the SDLC links configured on the PS.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaSDLCLinkEntryS

pktSwchSnaSDLCLinkEntryS 1.3.6.1.4.1.164.8.11.1.1
SDLC Link Entry defines the contents of each link in the SDLC Link Table.
OBJECT-TYPE    
  PktSwchSnaSDLCLinkEntryS  

pktSwchSnaSDLCLinkTypeS 1.3.6.1.4.1.164.8.11.1.1.1
This parameter identifies whether this link operates as TPAD(Primary) or HPAD(Secondary) SDLC device.
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

pktSwchSnaSDLCLinkPUSharedS 1.3.6.1.4.1.164.8.11.1.1.2
This parameter defines whether the link participates with more than one PU or not.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

pktSwchSnaSDLCLinkDuplexPhyS 1.3.6.1.4.1.164.8.11.1.1.3
This parameter describes whether the physical level of the SDLC line is half or full duplex.
OBJECT-TYPE    
  INTEGER half(1), full(2)  

pktSwchSnaSDLCLinkflagsS 1.3.6.1.4.1.164.8.11.1.1.4
Number of flags between frames.
OBJECT-TYPE    
  Integer32 1..15  

pktSwchSnaSDLCLinkDuplexS 1.3.6.1.4.1.164.8.11.1.1.5
This parameter shows wether the link level is Two Way Alternate or Two Way Simultaneous.
OBJECT-TYPE    
  INTEGER twoWayAlter(1), twoWaySimul(2)  

pktSwchSnaSDLCLinkClockS 1.3.6.1.4.1.164.8.11.1.1.6
This parameter defines the link clock rate
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600Bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48000bps(7), r56000bps(8), r64000bps(9), r128000bps(10), r256000bps(11), r384000bps(12), r504000bps(13), r768000bps(14), r1008000bps(15), r1466000bps(16), r2016000bps(17), external(255)  

pktSwchSnaSDLCLinkNRZS 1.3.6.1.4.1.164.8.11.1.1.7
This parameter describes the following combinations of NRZ, NRZI with FLAGS or IDLE between frames: Legal values: 1 - NRZ with FLAGs between frames. RTS is Constant 2 - NRZI with FLAGs between frames. RTS is Constant. 3 - NRZ with IDLE between frames. RTS is Controlled. 4 - NRZI with IDLE between frames. RTS is Controlled.
OBJECT-TYPE    
  INTEGER nrzFlags(1), nrziFlags(2), nrzIdle(3), nrziIdle(4)  

pktSwchSnaSDLCLinkTableA 1.3.6.1.4.1.164.8.11.2
The SDLC Link Table defines the SDLC links configured on the SPS.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaSDLCLinkEntryA

pktSwchSnaSDLCLinkEntryA 1.3.6.1.4.1.164.8.11.2.1
SDLC Link Entry defines the contents of each link in the SDLC Link Table.
OBJECT-TYPE    
  PktSwchSnaSDLCLinkEntryA  

pktSwchSnaSDLCLinkTypeA 1.3.6.1.4.1.164.8.11.2.1.1
This parameter identifies whether this link operates as TPAD(Primary) or HPAD(Secondary) SDLC device.
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

pktSwchSnaSDLCLinkPUSharedA 1.3.6.1.4.1.164.8.11.2.1.2
This parameter defines whether the link participates with more than one PU or not.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

pktSwchSnaSDLCLinkDuplexPhyA 1.3.6.1.4.1.164.8.11.2.1.3
This parameter describes whether the physical level of the SDLC line is half or full duplex.
OBJECT-TYPE    
  INTEGER half(1), full(2)  

pktSwchSnaSDLCLinkflagsA 1.3.6.1.4.1.164.8.11.2.1.4
Number of flags between frames.
OBJECT-TYPE    
  Integer32 1..15  

pktSwchSnaSDLCLinkDuplexA 1.3.6.1.4.1.164.8.11.2.1.5
This parameter shows wether the link level is Two Way Alternate or Two Way Simultaneous.
OBJECT-TYPE    
  INTEGER twoWayAlter(1), twoWaySimul(2)  

pktSwchSnaSDLCLinkClockA 1.3.6.1.4.1.164.8.11.2.1.6
This parameter defines the link clock rate.
OBJECT-TYPE    
  INTEGER r2400bps(1), r4800bps(2), r9600Bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48000bps(7), r56000bps(8), r64000bps(9), r128000bps(10), r256000bps(11), r384000bps(12), r504000bps(13), r768000bps(14), r1008000bps(15), r1466000bps(16), r2016000bps(17), external(255)  

pktSwchSnaSDLCLinkNRZA 1.3.6.1.4.1.164.8.11.2.1.7
This parameter describes the following combinations of NRZ, NRZI with FLAGS or IDLE between frames: Legal values: 1 - NRZ with FLAGs between frames. RTS is Constant 2 - NRZI with FLAGs between frames. RTS is Constant. 3 - NRZ with IDLE between frames. RTS is Controlled. 4 - NRZI with IDLE between frames. RTS is Controlled.
OBJECT-TYPE    
  INTEGER nrzFlags(1), nrziFlags(2), nrzIdle(3), nrziIdle(4)  

pktSwchSnaSDLCLinkStatFrames 1.3.6.1.4.1.164.8.11.2.1.8
The number of frames received or transmitted via this link
OBJECT-TYPE    
  Counter32  

pktSwchSnaSDLCLinkStatErrors 1.3.6.1.4.1.164.8.11.2.1.9
The number of error frames received.
OBJECT-TYPE    
  Counter32  

pktSwchSnaSDLCLinkStatInvalidAddresses 1.3.6.1.4.1.164.8.11.2.1.10
The number of frames with wrong address received by this link.
OBJECT-TYPE    
  Counter32  

pktSwchSnaSDLCLinkStatShortFrames 1.3.6.1.4.1.164.8.11.2.1.11
The number of short frames received by this link.
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUTableS 1.3.6.1.4.1.164.8.11.3
The SDLC PU table defines the PUs configured on the PS.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPUEntryS

pktSwchSnaPUEntryS 1.3.6.1.4.1.164.8.11.3.1
SDLC PU Entry defines the contents of each PU in the SDLC PU Table.
OBJECT-TYPE    
  PktSwchSnaPUEntryS  

pktSwchSnaPUNumberS 1.3.6.1.4.1.164.8.11.3.1.1
This parameter defines an identifier associated with the PU Entry which is unique within the SPS
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUXIDProcessingS 1.3.6.1.4.1.164.8.11.3.1.2
Exchange Identification (XID) processing. The following values are legal: 1 - Local XID handling 2 - End-to-End XID handling, Support for NON-Activation XID 3 - End-to-End XID handling, NO Support for NON-Activation XID
OBJECT-TYPE    
  INTEGER localXid(1), end2EndSupNoAct(2), end2EndNoSupNoAct(3)  

pktSwchSnaPUEnableS 1.3.6.1.4.1.164.8.11.3.1.3
The PU runs or not at this specific time
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

pktSwchSnaPULinkATypeS 1.3.6.1.4.1.164.8.11.3.1.4
The PU link A type.
OBJECT-TYPE    
  INTEGER sdlc(1), x25Qllc(2), frameRelayLLC2(3)  

pktSwchSnaPULinkARoleS 1.3.6.1.4.1.164.8.11.3.1.5
The PU role for link A. Note that the role of an SDLC PU may not be changed. It is defined by the SDLC Link Type.
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

pktSwchSnaPULinkBTypeS 1.3.6.1.4.1.164.8.11.3.1.6
The PU partner link B type
OBJECT-TYPE    
  INTEGER sdlc(1), x25Qllc(2), frameRelayLLC2(3)  

pktSwchSnaPULinkBRoleS 1.3.6.1.4.1.164.8.11.3.1.7
The PU role for link B. Note that the role of an SDLC PU may not be changed. It is defined by the SDLC Link Type.
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

pktSwchSnaPUEntryStatusS 1.3.6.1.4.1.164.8.11.3.1.8
The status of this PU table entry. This Set request will fail if there are any conflicts between any of of the parameter values in any of the tables comprising this PU definition
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchSnaPUTableA 1.3.6.1.4.1.164.8.11.4
The SDLC PU table defines the PUs configured on the PS.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPUEntryA

pktSwchSnaPUEntryA 1.3.6.1.4.1.164.8.11.4.1
SDLC PU Entry defines the contents of each PU in the SDLC PU Table.
OBJECT-TYPE    
  PktSwchSnaPUEntryA  

pktSwchSnaPUNumberA 1.3.6.1.4.1.164.8.11.4.1.1
This parameter defines an identifier associated with the PU Entry which is unique within the SPS
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUXIDProcessingA 1.3.6.1.4.1.164.8.11.4.1.2
The PU XID Processing
OBJECT-TYPE    
  INTEGER localXid(1), end2EndSupNoAct(2), end2EndNoSupNoAct(3)  

pktSwchSnaPUEnableA 1.3.6.1.4.1.164.8.11.4.1.3
The PU runs or not at this specific time
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

pktSwchSnaPULinkATypeA 1.3.6.1.4.1.164.8.11.4.1.4
The PU link type
OBJECT-TYPE    
  INTEGER sdlc(1), x25Qllc(2), frameRelayLLC2(3)  

pktSwchSnaPULinkARoleA 1.3.6.1.4.1.164.8.11.4.1.5
The PU role for link A
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

pktSwchSnaPULinkBTypeA 1.3.6.1.4.1.164.8.11.4.1.6
The PU partner link type
OBJECT-TYPE    
  INTEGER sdlc(1), x25Qllc(2), frameRelayLLC2(3)  

pktSwchSnaPULinkBRoleA 1.3.6.1.4.1.164.8.11.4.1.7
The PU role for link B
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

pktSwchSnaPUSdlcTableS 1.3.6.1.4.1.164.8.11.5
Defines links for PUs running on SDLC link
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPUSdlcEntryS

pktSwchSnaPUSdlcEntryS 1.3.6.1.4.1.164.8.11.5.1
Defines parameters of a link for a PU running on an SDLC link
OBJECT-TYPE    
  PktSwchSnaPUSdlcEntryS  

pktSwchSnaPUSdlcNumberS 1.3.6.1.4.1.164.8.11.5.1.1
This parameter defines an identifier associated with the PU Entry SDLC side, which is unique within the SPS
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUSdlcSideS 1.3.6.1.4.1.164.8.11.5.1.2
Is this side A or side B of the PU definition
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

pktSwchSnaPUSdlcAddressS 1.3.6.1.4.1.164.8.11.5.1.3
SNA SDLC PU address. Range: 0x00-0xFE
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

pktSwchSnaPUSdlcIfIndexS 1.3.6.1.4.1.164.8.11.5.1.4
ifIndex of the SDLC link
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUSdlcIdBlkS 1.3.6.1.4.1.164.8.11.5.1.5
Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idblk is required for secondary PU with Local XID handling. Up to 3 Hexadecimal digits, format: 0X XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..2)  

pktSwchSnaPUSdlcIdNumS 1.3.6.1.4.1.164.8.11.5.1.6
Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idnum is required for secondary PU with Local XID handling. Up to 5 Hexadecimal digits, format: 0X XX XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..3)  

pktSwchSnaPUSdlcMaxPiuSizeS 1.3.6.1.4.1.164.8.11.5.1.7
Maximum Path Information Size
OBJECT-TYPE    
  Integer32 137..7642  

pktSwchSnaPUSdlcTxWindowS 1.3.6.1.4.1.164.8.11.5.1.8
Window Size(in frames) used when sending from the SPS. Range: 1-7.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUSdlcGrpAddressS 1.3.6.1.4.1.164.8.11.5.1.9
SNA Group address used by the SPS when sending polls (TPAD ONLY). Range: 0x00-0xFE
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

pktSwchSnaPUSdlcPollTimerS 1.3.6.1.4.1.164.8.11.5.1.10
Time in between polls in 50 millisecond increments (TPAD ONLY). Range: 1-65535.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUSdlcXIDInitiationS 1.3.6.1.4.1.164.8.11.5.1.11
This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to SDLC.
OBJECT-TYPE    
  INTEGER notInitiate(1), initiate(2)  

pktSwchSnaPUSdlcEntryStatusS 1.3.6.1.4.1.164.8.11.5.1.12
The status of this PU Sdlc table entry. In order to save this entry, set status to valid. An underCreation value is set by the Agent when this entry is updated.
OBJECT-TYPE    
  INTEGER valid(1), underCreation(3)  

pktSwchSnaPUSdlcTableA 1.3.6.1.4.1.164.8.11.6
Defines links for PUs running on an SDLC link
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPUSdlcEntryA

pktSwchSnaPUSdlcEntryA 1.3.6.1.4.1.164.8.11.6.1
Defines parameters of link for PU running on an SDLC link
OBJECT-TYPE    
  PktSwchSnaPUSdlcEntryA  

pktSwchSnaPUSdlcNumberA 1.3.6.1.4.1.164.8.11.6.1.1
This parameter defines an identifier associated with the PU Entry SDLC side, which is unique within the SPS
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUSdlcSideA 1.3.6.1.4.1.164.8.11.6.1.2
Is this side A or side B of the PU definition
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

pktSwchSnaPUSdlcAddressA 1.3.6.1.4.1.164.8.11.6.1.3
SNA SDLC PU address. Range: 0x00-0xFE.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

pktSwchSnaPUSdlcIfIndexA 1.3.6.1.4.1.164.8.11.6.1.4
ifIndex of the SDLC link
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUSdlcIdBlkA 1.3.6.1.4.1.164.8.11.6.1.5
Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idblk is required for secondary PU with Local XID handling. Up to 3 Hexadecimal digits, format: 0X XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..2)  

pktSwchSnaPUSdlcIdNumA 1.3.6.1.4.1.164.8.11.6.1.6
Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idnum is required for secondary PU with Local XID handling. Up to 5 Hexadecimal digits, format: 0X XX XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..3)  

pktSwchSnaPUSdlcMaxPiuSizeA 1.3.6.1.4.1.164.8.11.6.1.7
Maximum Path Information Size
OBJECT-TYPE    
  Integer32 137..7642  

pktSwchSnaPUSdlcTxWindowA 1.3.6.1.4.1.164.8.11.6.1.8
Window Size(in frames) used when sending from the SPS. Range: 1-7.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUSdlcGrpAddressA 1.3.6.1.4.1.164.8.11.6.1.9
SNA Group address used by the SPS when sending polls (TPAD ONLY). Range: 0x00-0xFE.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

pktSwchSnaPUSdlcPollTimerA 1.3.6.1.4.1.164.8.11.6.1.10
Time in between polls in 50 millisecond increments (TPAD ONLY). Range: 1-65535.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUSdlcXIDInitiationA 1.3.6.1.4.1.164.8.11.6.1.11
This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to SDLC.
OBJECT-TYPE    
  INTEGER notInitiate(1), initiate(2)  

pktSwchSnaPUSdlcStatTable 1.3.6.1.4.1.164.8.11.7
Shows Link Statistics for PUs running on an SDLC link
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPUSdlcStatEntry

pktSwchSnaPUSdlcStatEntry 1.3.6.1.4.1.164.8.11.7.1
Shows Link Statistics for PUs running on an SDLC link
OBJECT-TYPE    
  PktSwchSnaPUSdlcStatEntry  

pktSwchSnaPUSdlcStatNumber 1.3.6.1.4.1.164.8.11.7.1.1
This parameter defines an identifier associated with the PU Entry SDLC side statistics, which is unique within the SPS
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUSdlcStatSide 1.3.6.1.4.1.164.8.11.7.1.2
Is this side A or side B of the PU definition
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

pktSwchSnaPUSdlcStatOctetsIn 1.3.6.1.4.1.164.8.11.7.1.3
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatOctetsOut 1.3.6.1.4.1.164.8.11.7.1.4
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatIFramesIn 1.3.6.1.4.1.164.8.11.7.1.5
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatIFramesOut 1.3.6.1.4.1.164.8.11.7.1.6
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatRRFramesIn 1.3.6.1.4.1.164.8.11.7.1.7
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatRRFramesOut 1.3.6.1.4.1.164.8.11.7.1.8
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatRNRFramesIn 1.3.6.1.4.1.164.8.11.7.1.9
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatRNRFramesOut 1.3.6.1.4.1.164.8.11.7.1.10
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatXIDsIn 1.3.6.1.4.1.164.8.11.7.1.11
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatXIDsOut 1.3.6.1.4.1.164.8.11.7.1.12
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatTESTsIn 1.3.6.1.4.1.164.8.11.7.1.13
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatTESTsOut 1.3.6.1.4.1.164.8.11.7.1.14
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatREJsIn 1.3.6.1.4.1.164.8.11.7.1.15
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatREJsOut 1.3.6.1.4.1.164.8.11.7.1.16
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatFRMRsIn 1.3.6.1.4.1.164.8.11.7.1.17
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatFRMRsOut 1.3.6.1.4.1.164.8.11.7.1.18
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatDISCsIn 1.3.6.1.4.1.164.8.11.7.1.19
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatDISCsOut 1.3.6.1.4.1.164.8.11.7.1.20
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatUAsIn 1.3.6.1.4.1.164.8.11.7.1.21
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatUAsOut 1.3.6.1.4.1.164.8.11.7.1.22
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatDMsIn 1.3.6.1.4.1.164.8.11.7.1.23
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatDMsOut 1.3.6.1.4.1.164.8.11.7.1.24
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatSNRMsIn 1.3.6.1.4.1.164.8.11.7.1.25
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatSNRMsOut 1.3.6.1.4.1.164.8.11.7.1.26
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatRetransmitsIn 1.3.6.1.4.1.164.8.11.7.1.27
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcStatRetransmitsOut 1.3.6.1.4.1.164.8.11.7.1.28
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUSdlcUpperState 1.3.6.1.4.1.164.8.11.7.1.29
The internal DLPI state of the connection.
OBJECT-TYPE    
  INTEGER unbound(1), bindPending(2), unbindPend(3), idle(4), unattached(5), attachPend(6), detachPend(7), udqosPending(8), outconPend(9), inconPending(10), connResPend(11), dataxfer(12), userResetPend(13), provRstPend(14), rstResPend(15), discon8Pend(16), discon9Pend(17), discon11Pend(18), discon12Pend(19), discon13Pend(20), subsBindPnd(21), noChange(22)  

pktSwchSnaPUSdlcLowerState 1.3.6.1.4.1.164.8.11.7.1.30
The internal SDLC state of the connection.
OBJECT-TYPE    
  INTEGER linkClosed(1), disconnected(2), linkOpening(3), disconnecting(4), frmrSent(5), linkOpened(6), localBusy(7), rejection(8), checkpointing(9), cpLocalBusy(10), cpRejection(11), resetting(12), remoteBusy(13), lBusyRBusy(14), rejLBusy(15), rejRBusy(16), cpRejLBusy(17), cpClearing(18), cpRejClr(19), rejLbusyRbusy(20), frmrReceived(21), programError(22), noChange(23)  

pktSwchSnaPUSdlcStatNRMStatus 1.3.6.1.4.1.164.8.11.7.1.31
This variable indicates if the link is in Normal Response Mode or not.
OBJECT-TYPE    
  INTEGER sync(1), notSync(2)  

pktSwchSnaPUSdlcStatFlowCtlStatus 1.3.6.1.4.1.164.8.11.7.1.32
This variable indicates the flow control status of the PU interface.
OBJECT-TYPE    
  INTEGER noRNR(1), txFlow(2), rxFlow(3), rxAndTx(4)  

pktSwchSnaPUSX25QllcTableS 1.3.6.1.4.1.164.8.11.8
Defines links for PUs running on a QLLC link
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPUX25QllcEntryS

pktSwchSnaPUX25QllcEntryS 1.3.6.1.4.1.164.8.11.8.1
Defines parameters for PU side running on SDLC link
OBJECT-TYPE    
  PktSwchSnaPUX25QllcEntryS  

pktSwchSnaPUX25QllcNumberS 1.3.6.1.4.1.164.8.11.8.1.1
This parameter defines an identifier associated with the PU Entry X25\QLLC side, which is unique within the SPS
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUX25QllcSideS 1.3.6.1.4.1.164.8.11.8.1.2
Is there side A or B of the PU connection
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

pktSwchSnaPUX25QllcIdBlkS 1.3.6.1.4.1.164.8.11.8.1.3
Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idblk is required for secondary PU with Local XID handling. Up to 3 Hexadecimal digits, format: 0X XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..2)  

pktSwchSnaPUX25QllcIdNumS 1.3.6.1.4.1.164.8.11.8.1.4
Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idnum is required for secondary PU with Local XID handling. Up to 5 Hexadecimal digits, format: 0X XX XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..3)  

pktSwchSnaPUX25QllcXIDInitS 1.3.6.1.4.1.164.8.11.8.1.5
This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to QLLC.
OBJECT-TYPE    
  INTEGER notInitiate(1), initiate(2)  

pktSwchSnaPUX25QllcMaxPiuSizeS 1.3.6.1.4.1.164.8.11.8.1.6
Maximum Path Information Size
OBJECT-TYPE    
  Integer32 137..7642  

pktSwchSnaPUX25QllcStationAddressS 1.3.6.1.4.1.164.8.11.8.1.7
QLLC PU Link Station Address. Range: 0x01-0xFE. This parameter is applicable only for PU with End-to-End XID handling, Support for NON-Activation XID.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

pktSwchSnaPUX25QllcInPasswordS 1.3.6.1.4.1.164.8.11.8.1.8
A field matched with the call user data in call request packets for purposes of security and correlation.
OBJECT-TYPE    
  DisplayString SIZE(1..8)  

pktSwchSnaPUX25QllcSubAddressS 1.3.6.1.4.1.164.8.11.8.1.9
The X.25 Sub-address associated with the PU Entry for routing incoming call indications. Range: 0-99.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUX25QllcAutoCallS 1.3.6.1.4.1.164.8.11.8.1.10
This parameter indicates whether the SPS automatically initiates an X.25 call request or not.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

pktSwchSnaPUX25QllcCalledAddressS 1.3.6.1.4.1.164.8.11.8.1.11
The destination x.25 DTE address to which the SPS calls. Used with AutoCall only.
OBJECT-TYPE    
  OCTET STRING SIZE(1..15)  

pktSwchSnaPUX25QllcCallUserDataFacilitiesS 1.3.6.1.4.1.164.8.11.8.1.12
The X.25 facilities and Call User Data which the SPS uses on outgoing calls. AutoCall only. Up to 60 Hexa-Decimal digits. Each pair of digits represents a BYTE. BYTE-0 BYTE-1 BYTE-2 ... BYTE-29 (30 Bytes maximum) BYTE-0 for X.25 Facilities. BYTE-1 to BYTE-29 for Call User Data. Facilities (BYTE-0) format: PW (Hexa-Decimal), where: X.25 L3 Packet Size Negotiation : [P=1 YES] [P=0 NO]. X.25 L3 Packet Window Negotiation : [W=1 YES] [W=0 NO]. Legal Values for Facilities BYTE-0 : 10, 01, 11, 00 (Hex). ATTENTION: a. Total number of digits in this field must be EVEN. b. To clear this field, enter blanks or 00.
OBJECT-TYPE    
  DisplayString SIZE(1..60)  

pktSwchSnaPUX25QllcEntryStatusS 1.3.6.1.4.1.164.8.11.8.1.13
The status of this PU Qllc table entry. In order to save this entry, set status to valid. An underCreation value is set by the Agent when this entry is updated.
OBJECT-TYPE    
  INTEGER valid(1), underCreation(3)  

pktSwchSnaPUX25QllcTableA 1.3.6.1.4.1.164.8.11.9
Defines links for PUs running on a QLLC link
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPUX25QllcEntryA

pktSwchSnaPUX25QllcEntryA 1.3.6.1.4.1.164.8.11.9.1
Defines parameters for PU side running on an SDLC link
OBJECT-TYPE    
  PktSwchSnaPUX25QllcEntryA  

pktSwchSnaPUX25QllcNumberA 1.3.6.1.4.1.164.8.11.9.1.1
This parameter defines an identifier associated with the PU Entry X25\QLLC side, which is unique within the SPS
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUX25QllcSideA 1.3.6.1.4.1.164.8.11.9.1.2
Is there side A or B of the PU connection
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

pktSwchSnaPUX25QllcIdBlkA 1.3.6.1.4.1.164.8.11.9.1.3
Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idblk is required for secondary PU with Local XID handling. Up to 3 Hexadecimal digits, format: 0X XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..2)  

pktSwchSnaPUX25QllcIdNumA 1.3.6.1.4.1.164.8.11.9.1.4
Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idnum is required for secondary PU with Local XID handling. Up to 5 Hexadecimal digits, format: 0X XX XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..3)  

pktSwchSnaPUX25QllcXIDInitA 1.3.6.1.4.1.164.8.11.9.1.5
This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to QLLC.
OBJECT-TYPE    
  INTEGER notInitiate(1), initiate(2)  

pktSwchSnaPUX25QllcMaxPiuSizeA 1.3.6.1.4.1.164.8.11.9.1.6
Maximum Path Information Size
OBJECT-TYPE    
  Integer32 137..7642  

pktSwchSnaPUX25QllcStationAddressA 1.3.6.1.4.1.164.8.11.9.1.7
QLLC PU Link Station Address. Range: 0x01-0xFE. This parameter is applicable only for PU with End-to-End XID handling, Support for NON-Activation XID.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

pktSwchSnaPUX25QllcInPasswordA 1.3.6.1.4.1.164.8.11.9.1.8
A field matched with the call user data in call request packets for purposes of security and correlation.
OBJECT-TYPE    
  DisplayString SIZE(1..8)  

pktSwchSnaPUX25QllcSubAddressA 1.3.6.1.4.1.164.8.11.9.1.9
The X.25 Sub-address associated with the PU Entry for routing incoming call indications. Range: 0-99.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUX25QllcAutoCallA 1.3.6.1.4.1.164.8.11.9.1.10
This parameter indicates whether the SPS automatically initiates an X.25 call request or not.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

pktSwchSnaPUX25QllcCalledAddressA 1.3.6.1.4.1.164.8.11.9.1.11
The destination x.25 DTE address to which the SPS calls. Used with AutoCall only.
OBJECT-TYPE    
  OCTET STRING SIZE(1..15)  

pktSwchSnaPUX25QllcCallUserDataFacilitiesA 1.3.6.1.4.1.164.8.11.9.1.12
The X.25 facilities and Call User Data which the SPS uses on outgoing calls. AutoCall only. Up to 60 Hexa-Decimal digits. Each pair of digits represents a BYTE. BYTE-0 BYTE-1 BYTE-2 ... BYTE-29 (30 Bytes maximum) BYTE-0 for X.25 Facilities. BYTE-1 to BYTE-29 for Call User Data. Facilities (BYTE-0) format: PW (Hexa-Decimal), where: X.25 L3 Packet Size Negotiation : [P=1 YES] [P=0 NO]. X.25 L3 Packet Window Negotiation : [W=1 YES] [W=0 NO]. Legal Values for Facilities BYTE-0 : 10, 01, 11, 00 (Hex). ATTENTION: a. Total number of digits in this field must be EVEN. b. To clear this field, enter blanks or 00.
OBJECT-TYPE    
  DisplayString SIZE(1..60)  

pktSwchSnaPUX25QllcStatTable 1.3.6.1.4.1.164.8.11.10
Shows link statistics for PUs running on a QLLC link
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPUX25QllcStatEntry

pktSwchSnaPUX25QllcStatEntry 1.3.6.1.4.1.164.8.11.10.1
Shows link statistics for PUs running on a QLLC link
OBJECT-TYPE    
  PktSwchSnaPUX25QllcStatEntry  

pktSwchSnaPUX25QllcStatNumber 1.3.6.1.4.1.164.8.11.10.1.1
This parameter defines an identifier associated with the PU Entry X25\QLLC side, which is unique within the SPS
OBJECT-TYPE    
  Integer32  

pktSwchSnaPUX25QllcStatSide 1.3.6.1.4.1.164.8.11.10.1.2
Is there side A or B of the PU connection
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  


pktSwchSnaPUX25QllcStatDataPacketsIn 1.3.6.1.4.1.164.8.11.10.1.4
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatDataPacketsOut 1.3.6.1.4.1.164.8.11.10.1.5
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatQSMPacketsIn 1.3.6.1.4.1.164.8.11.10.1.6
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatQSMPacketsOut 1.3.6.1.4.1.164.8.11.10.1.7
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatQDMPacketsIn 1.3.6.1.4.1.164.8.11.10.1.8
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatQDMPacketsOut 1.3.6.1.4.1.164.8.11.10.1.9
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatXIDPacketsIn 1.3.6.1.4.1.164.8.11.10.1.10
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatXIDPacketsOut 1.3.6.1.4.1.164.8.11.10.1.11
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatQDISCPacketsIn 1.3.6.1.4.1.164.8.11.10.1.12
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatQDISCPacketsOut 1.3.6.1.4.1.164.8.11.10.1.13
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatCallPacketsIn 1.3.6.1.4.1.164.8.11.10.1.14
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatCallPacketsOut 1.3.6.1.4.1.164.8.11.10.1.15
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatClearPacketsIn 1.3.6.1.4.1.164.8.11.10.1.16
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatClearPacketsOut 1.3.6.1.4.1.164.8.11.10.1.17
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatCallAcceptsIn 1.3.6.1.4.1.164.8.11.10.1.18
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatCallAcceptsOut 1.3.6.1.4.1.164.8.11.10.1.19
OBJECT-TYPE    
  Counter32  

pktSwchSnaPUX25QllcStatUpperState 1.3.6.1.4.1.164.8.11.10.1.20
The internal DLPI state of the connection.
OBJECT-TYPE    
  INTEGER unbound(1), bindPending(2), unbindPend(3), idle(4), unattached(5), attachPend(6), detachPend(7), udqosPending(8), outconPend(9), inconPending(10), connResPend(11), dataxfer(12), userResetPend(13), provRstPend(14), rstResPend(15), discon8Pend(16), discon9Pend(17), discon11Pend(18), discon12Pend(19), discon13Pend(20), subsBindPnd(21), noChange(22)  

pktSwchSnaPUX25QllcStatLowerState 1.3.6.1.4.1.164.8.11.10.1.21
The internal QLLC state of the connection.
OBJECT-TYPE    
  INTEGER linkClosed(1), disconnected(2), linkOpening(3), disconnecting(4), frmrSent(5), linkOpened(6), localBusy(7), rejection(8), checkpointing(9), cpLocalBusy(10), cpRejection(11), resetting(12), remoteBusy(13), lBusyRBusy(14), rejLBusy(15), rejRBusy(16), cpRejLBusy(17), cpClearing(18), cpRejClr(19), rejLbusyRbusy(20), frmrReceived(21), programError(22), noChange(23)  

pktSwchSnaPUX25QllcStatNRMStatus 1.3.6.1.4.1.164.8.11.10.1.22
This variable indicates if the link is in Normal Response Mode or not.
OBJECT-TYPE    
  INTEGER sync(1), notSync(2)  

pktSwchSnaPUX25QllcStatFlowCtlStatus 1.3.6.1.4.1.164.8.11.10.1.23
This variable indicates the flow control status of the PU interface.
OBJECT-TYPE    
  INTEGER noRNR(1), txFlow(2), rxFlow(3), rxAndTx(4)  

pktSwchSnaPULlc2FrTableS 1.3.6.1.4.1.164.8.11.11
Defines LLC2/Frame Relay/RFC1490 Protocol Interface of SPS SNA PU entity.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPULlc2FrEntryS

pktSwchSnaPULlc2FrEntryS 1.3.6.1.4.1.164.8.11.11.1
Defines parameters for PU LLC2 Protocol Interface over Frame Relay Protocol using RFC 1490.
OBJECT-TYPE    
  PktSwchSnaPULlc2FrEntryS  

pktSwchSnaPULlc2FrNumberS 1.3.6.1.4.1.164.8.11.11.1.1
Unique Identifier for this PU. The value in this field is used as a common Key in both this table and the Main PU table.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPULlc2FrSideS 1.3.6.1.4.1.164.8.11.11.1.2
Indicates for each side (SIDE-A and SIDE-B) if the Protocol Interface for that side has been defined or not.
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

pktSwchSnaPULlc2FrEncapsTypeS 1.3.6.1.4.1.164.8.11.11.1.3
Indicates if the LLC2/RFC1490 Protocol Interface uses the BNN, BAN or TREN method of Frame Encapsulation.
OBJECT-TYPE    
  INTEGER ban(1), bnn(2), tren(3)  

pktSwchSnaPULlc2FrDestMACS 1.3.6.1.4.1.164.8.11.11.1.4
The LLC2 Destination MAC Address.
OBJECT-TYPE    
  OCTET STRING SIZE(6)  

pktSwchSnaPULlc2FrSrcSAPS 1.3.6.1.4.1.164.8.11.11.1.5
The LLC2 Source SAP Address. 2 Hex digits
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

pktSwchSnaPULlc2FrDestSAPS 1.3.6.1.4.1.164.8.11.11.1.6
The LLC2 Destination SAP.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

pktSwchSnaPULlc2FrXIDIdBlkS 1.3.6.1.4.1.164.8.11.11.1.7
Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The IDBLK is required for PU with Local XID handling or PU with End-to-End XID handling, NO Support for NON-Activation XID. Up to 3 Hexadecimal digits, format: 0X XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..2)  

pktSwchSnaPULlc2FrXIDIdNumS 1.3.6.1.4.1.164.8.11.11.1.8
Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The IDNUM is required for PU with Local XID handling or PU with End-to-End XID handling, NO Support for NON-Activation XID. Up to 5 Hexadecimal digits, format: 0X XX XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..3)  

pktSwchSnaPULlc2FrMaxPiuSizeS 1.3.6.1.4.1.164.8.11.11.1.9
Maximum Path Information Size
OBJECT-TYPE    
  Integer32 137..7642  

pktSwchSnaPULlc2FrTxWindowS 1.3.6.1.4.1.164.8.11.11.1.10
The LLC2 Link Window Size.
OBJECT-TYPE    
  Integer32  


pktSwchSnaPULlc2FrDLCIS 1.3.6.1.4.1.164.8.11.11.1.12
The SPS Frame Relay DLCI Number which this LLC2 Protocol Interface is associated with.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPULlc2FrXIDInitiationS 1.3.6.1.4.1.164.8.11.11.1.13
This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to LLC2.
OBJECT-TYPE    
  INTEGER notInitiate(1), initiate(2)  

pktSwchSnaPULlc2FrN2CountS 1.3.6.1.4.1.164.8.11.11.1.14
N2 Count
OBJECT-TYPE    
  Integer32 1..99999  

pktSwchSnaPULlc2FrT1TimerS 1.3.6.1.4.1.164.8.11.11.1.15
T1 Timer in 1/10 of a second.
OBJECT-TYPE    
  Integer32 1..99999  

pktSwchSnaPULlc2FrTiTimerS 1.3.6.1.4.1.164.8.11.11.1.16
TI Timer in seconds
OBJECT-TYPE    
  Integer32 1..99999  

pktSwchSnaPULlc2FrEntryStatusS 1.3.6.1.4.1.164.8.11.11.1.17
The status of this PU Llc2 table entry. In order to save this entry, set status to valid. An underCreation value is set by the Agent when this entry is updated.
OBJECT-TYPE    
  INTEGER valid(1), underCreation(3)  

pktSwchSnaPULlc2FrTableA 1.3.6.1.4.1.164.8.11.12
Defines links for PUs running on an LLC2 link
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPULlc2FrEntryA

pktSwchSnaPULlc2FrEntryA 1.3.6.1.4.1.164.8.11.12.1
Defines parameters for PU LLC2 Protocol Interface over Frame Relay Protocol using RFC 1490.
OBJECT-TYPE    
  PktSwchSnaPULlc2FrEntryA  

pktSwchSnaPULlc2FrNumberA 1.3.6.1.4.1.164.8.11.12.1.1
Unique Identifier for this PU. The value in this field is used as a common Key in both this table and the Main PU table.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPULlc2FrSideA 1.3.6.1.4.1.164.8.11.12.1.2
Indicates for each side (SIDE-A and SIDE-B) if the Protocol Interface for that side has been defined or not.
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

pktSwchSnaPULlc2FrEncapsTypeA 1.3.6.1.4.1.164.8.11.12.1.3
Indicates if the LLC2/RFC1490 Protocol Interface uses the BNN, BAN or TREN method of Frame Encapsulation.
OBJECT-TYPE    
  INTEGER ban(1), bnn(2), tren(3)  

pktSwchSnaPULlc2FrDestMACA 1.3.6.1.4.1.164.8.11.12.1.4
The LLC2 Destination MAC Address.
OBJECT-TYPE    
  OCTET STRING SIZE(6)  

pktSwchSnaPULlc2FrSrcSAPA 1.3.6.1.4.1.164.8.11.12.1.5
The LLC2 Source SAP Address.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

pktSwchSnaPULlc2FrDestSAPA 1.3.6.1.4.1.164.8.11.12.1.6
The LLC2 Destination SAP.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

pktSwchSnaPULlc2FrXIDIdBlkA 1.3.6.1.4.1.164.8.11.12.1.7
Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The IDBLK is required for PU with Local XID handling or PU with End-to-End XID handling, NO Support for NON-Activation XID. Up to 3 Hexadecimal digits, format: 0X XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..2)  

pktSwchSnaPULlc2FrXIDIdNumA 1.3.6.1.4.1.164.8.11.12.1.8
Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The IDNUM is required for PU with Local XID handling or PU with End-to-End XID handling, NO Support for NON-Activation XID. Up to 5 Hexadecimal digits, format: 0X XX XX.
OBJECT-TYPE    
  OCTET STRING SIZE(1..3)  

pktSwchSnaPULlc2FrMaxPiuSizeA 1.3.6.1.4.1.164.8.11.12.1.9
Maximum Path Information Size
OBJECT-TYPE    
  Integer32 137..7642  

pktSwchSnaPULlc2FrTxWindowA 1.3.6.1.4.1.164.8.11.12.1.10
The LLC2 Link Window Size.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPULlc2FrLinkA 1.3.6.1.4.1.164.8.11.12.1.11
The SPS Frame Relay Link Number which this LLC2 Protocol Interface is associated with.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPULlc2FrDLCIA 1.3.6.1.4.1.164.8.11.12.1.12
The SPS Frame Relay DLCI Number which this LLC2 Protocol Interface is associated with.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPULlc2FrXIDInitiationA 1.3.6.1.4.1.164.8.11.12.1.13
This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to LLC2.
OBJECT-TYPE    
  INTEGER notInitiate(1), initiate(2)  

pktSwchSnaPULlc2FrN2CountA 1.3.6.1.4.1.164.8.11.12.1.14
N2 Count
OBJECT-TYPE    
  Integer32 1..99999  

pktSwchSnaPULlc2FrT1TimerA 1.3.6.1.4.1.164.8.11.12.1.15
T1 Timer in 1/10 of a second.
OBJECT-TYPE    
  Integer32 1..99999  

pktSwchSnaPULlc2FrTiTimerA 1.3.6.1.4.1.164.8.11.12.1.16
TI Timer in seconds
OBJECT-TYPE    
  Integer32 1..99999  

pktSwchSnaPULlc2FrStatTable 1.3.6.1.4.1.164.8.11.13
Shows link statistics for PUs running on an LLC2 link
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchSnaPULlc2FrStatEntry

pktSwchSnaPULlc2FrStatEntry 1.3.6.1.4.1.164.8.11.13.1
Shows statistics for PU LLC2 Protocol Interface over Frame Relay Protocol using RFC 1490.
OBJECT-TYPE    
  PktSwchSnaPULlc2FrStatEntry  

pktSwchSnaPULlc2FrStatNumber 1.3.6.1.4.1.164.8.11.13.1.1
Unique Identifier for this PU. The value in this field is used as a common Key in both this table and the Main PU table.
OBJECT-TYPE    
  Integer32  

pktSwchSnaPULlc2FrStatSide 1.3.6.1.4.1.164.8.11.13.1.2
Indicates for each side (SIDE-A and SIDE-B) if the Protocol Interface for that side has been defined or not.
OBJECT-TYPE    
  INTEGER sideA(1), sideB(2)  

pktSwchSnaPULlc2FrStatOctetsIn 1.3.6.1.4.1.164.8.11.13.1.3
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatOctetsOut 1.3.6.1.4.1.164.8.11.13.1.4
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatIFramesIn 1.3.6.1.4.1.164.8.11.13.1.5
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatIFramesOut 1.3.6.1.4.1.164.8.11.13.1.6
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatRRFramesIn 1.3.6.1.4.1.164.8.11.13.1.7
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatRRFramesOut 1.3.6.1.4.1.164.8.11.13.1.8
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatRNRFramesIn 1.3.6.1.4.1.164.8.11.13.1.9
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatRNRFramesOut 1.3.6.1.4.1.164.8.11.13.1.10
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatXIDsIn 1.3.6.1.4.1.164.8.11.13.1.11
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatXIDsOut 1.3.6.1.4.1.164.8.11.13.1.12
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatTESTsIn 1.3.6.1.4.1.164.8.11.13.1.13
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatTESTsOut 1.3.6.1.4.1.164.8.11.13.1.14
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatREJsIn 1.3.6.1.4.1.164.8.11.13.1.15
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatREJsOut 1.3.6.1.4.1.164.8.11.13.1.16
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatFRMRsIn 1.3.6.1.4.1.164.8.11.13.1.17
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatFRMRsOut 1.3.6.1.4.1.164.8.11.13.1.18
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatDISCsIn 1.3.6.1.4.1.164.8.11.13.1.19
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatDISCsOut 1.3.6.1.4.1.164.8.11.13.1.20
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatUAsIn 1.3.6.1.4.1.164.8.11.13.1.21
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatUAsOut 1.3.6.1.4.1.164.8.11.13.1.22
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatDMsIn 1.3.6.1.4.1.164.8.11.13.1.23
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatDMsOut 1.3.6.1.4.1.164.8.11.13.1.24
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatSABMEsIn 1.3.6.1.4.1.164.8.11.13.1.25
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatSABMEsOut 1.3.6.1.4.1.164.8.11.13.1.26
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatRetransmitsIn 1.3.6.1.4.1.164.8.11.13.1.27
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatRetransmitsOut 1.3.6.1.4.1.164.8.11.13.1.28
OBJECT-TYPE    
  Counter32  

pktSwchSnaPULlc2FrStatUpperState 1.3.6.1.4.1.164.8.11.13.1.29
The internal DLPI state of the connection.
OBJECT-TYPE    
  INTEGER unbound(1), bindPending(2), unbindPend(3), idle(4), unattached(5), attachPend(6), detachPend(7), udqosPending(8), outconPend(9), inconPending(10), connResPend(11), dataxfer(12), userResetPend(13), provRstPend(14), rstResPend(15), discon8Pend(16), discon9Pend(17), discon11Pend(18), discon12Pend(19), discon13Pend(20), subsBindPend(21), noChange(22)  

pktSwchSnaPULlc2FrStatLowerState 1.3.6.1.4.1.164.8.11.13.1.30
The internal Llc2Fr state of the connection.
OBJECT-TYPE    
  INTEGER linkClosed(1), disconnected(2), linkOpening(3), disconnecting(4), frmrSent(5), linkOpened(6), localBusy(7), rejection(8), checkpointing(9), cpLocalBusy(10), cpRejection(11), resetting(12), remoteBusy(13), lBusyRBusy(14), rejLBusy(15), rejRBusy(16), cpRejLBusy(17), cpClearing(18), cpRejClr(19), rejLbusyRbusy(20), frmrReceived(21), programError(22), noChange(23)  

pktSwchSnaPULlc2FrStatNRMStatus 1.3.6.1.4.1.164.8.11.13.1.31
This variable indicates if the link is in Normal Response Mode or not.
OBJECT-TYPE    
  INTEGER sync(1), notSync(2)  

pktSwchSnaPULlc2FrStatFlowCtlStatus 1.3.6.1.4.1.164.8.11.13.1.32
This variable indicates the flow control status of the PU interface.
OBJECT-TYPE    
  INTEGER noRNR(1), txFlow(2), rxFlow(3), rxAndTx(4)  

pktSwchSnaGlobal 1.3.6.1.4.1.164.8.11.14
OBJECT IDENTIFIER    

pktSwchSnaGlobalSrcMacAddrS 1.3.6.1.4.1.164.8.11.14.1
LLC2 source MAC address used for all LLC2\RFC1490 protocol interfaces, Scratch variable. Format: XX XX XX XX XX XX
OBJECT-TYPE    
  OCTET STRING SIZE(6)  

pktSwchSnaGlobalSrcMacAddrA 1.3.6.1.4.1.164.8.11.14.2
LLC2 source MAC address used for all LLC2\RFC1490 protocol interfaces, Active variable. Format: XX XX XX XX XX XX
OBJECT-TYPE    
  OCTET STRING SIZE(6)  


pktSwchSnaGlobalDefFrLlc2LinkA 1.3.6.1.4.1.164.8.11.14.4
The FR Link to where a mac frame will be routed when the destination MAC address of the frame does not match the SPS source mac address.
OBJECT-TYPE    
  Integer32  

pktSwchSnaGlobalDefFrLlc2DlciS 1.3.6.1.4.1.164.8.11.14.5
The FR DLCI to where a mac frame will be routed when the destination MAC address of the frame does not match the SPS source mac address. DLCI range is 16..991.
OBJECT-TYPE    
  Integer32  

pktSwchSnaGlobalDefFrLlc2DlciA 1.3.6.1.4.1.164.8.11.14.6
The FR DLCI to where a mac frame will be routed when the destination MAC address of the frame does not match the SPS source mac address. DLCI range is 16..991.
OBJECT-TYPE    
  Integer32  

pktSwchSnaGlobalMaxPus 1.3.6.1.4.1.164.8.11.14.7
The maximum number of PUs that can be defined on this device.
OBJECT-TYPE    
  Integer32  

pktSwchSnaGlobalStatus 1.3.6.1.4.1.164.8.11.14.8
The status of this SNA Global entry. Used for saving the mac address, llc2 port, and dlci.
OBJECT-TYPE    
  INTEGER valid(1), underCreation(3)  

pktSwchEthernet 1.3.6.1.4.1.164.8.12
OBJECT IDENTIFIER    

pktSwchEthernetLinkTable 1.3.6.1.4.1.164.8.12.1
The Ethernet link table defines the parameters in the PS Ethernet links.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchEthernetLinkEntry

pktSwchEthernetLinkEntry 1.3.6.1.4.1.164.8.12.1.1
The Ethernet Link Entry defines the contents of each link in the Ethernet Link Table.
OBJECT-TYPE    
  PktSwchEthernetLinkEntry  

pktSwchEthernetLinkOperationMode 1.3.6.1.4.1.164.8.12.1.1.1
This parameter shows the frame handling mode on this link. When IP mode is defined, the IP frames received on this link are handled and routed by the IP module in the PS. If IP mode is disabled, the IP frames will not be handled by the IP module and will be handled as bridged data. When Bridging mode is enabled, the PS will perform bridging from this link according to the bridging configuration. If disabled, bridge data will be ignored. When LLC is enabled, frames received on this link are handled by the LLC module in the PS. If disabled, the LLC frames will be treated as bridged data. Any combination of bridging, ip and LLC is allowed. If both IP and LLC are enabled, LLC frames will be handled by the LLC module, IP frames will be handled by the IP module, and all the other frames will treated as bridged data. If the bridge mode is disabled, the other frames will be discarded.
OBJECT-TYPE    
  INTEGER bridging(3), ip(4), ip-and-bridging(7), llc(8), llc-and-bridging(11), ip-and-llc(12), all(15), none(255)  

pktSwchEthernetLinkUserDefMacAddr 1.3.6.1.4.1.164.8.12.1.1.2
This parameter allows the user to define a different MAC address for this link other than the device MAC address. Possible values: 6 sets of 2 Hexadecimal digits with spaces between them (XX XX XX XX XX XX)
OBJECT-TYPE    
  OCTET STRING SIZE(6)  

pktSwchEthernetLinkPointToPointDest 1.3.6.1.4.1.164.8.12.1.1.3
Destination of the frames which are received on this link. Possible values: X.25 PVC: Port:LCN X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID number. Frame Relay: Port:DLCI No Destination: None If no destination, frames will be forwarded according to the filter table in 1st priority. If no filter match, the frames will be forwarded according to dynamic learning. Default value: None
OBJECT-TYPE    
  DisplayString  

pktSwchEthernetLinkTotalFramesIn 1.3.6.1.4.1.164.8.12.1.1.4
Total number of frames which were received on this link.
OBJECT-TYPE    
  Counter32  

pktSwchEthernetLinkTotalFramesOut 1.3.6.1.4.1.164.8.12.1.1.5
Total number of frames which were transmitted from this link.
OBJECT-TYPE    
  Counter32  

pktSwchEthernetLinkIpFramesIn 1.3.6.1.4.1.164.8.12.1.1.6
Number of IP frames which were received on this link.
OBJECT-TYPE    
  Counter32  

pktSwchEthernetLinkIpFramesOut 1.3.6.1.4.1.164.8.12.1.1.7
Number of IP frames which were transmitted from this link.
OBJECT-TYPE    
  Counter32  

pktSwchEthernetLinkLlc2FramesIn 1.3.6.1.4.1.164.8.12.1.1.8
Number of LLC2 frames which were received on this link.
OBJECT-TYPE    
  Counter32  

pktSwchEthernetLinkLlc2FramesOut 1.3.6.1.4.1.164.8.12.1.1.9
Number of LLC2 frames which were transmitted from this link.
OBJECT-TYPE    
  Counter32  

pktSwchEthernetLinkBridgFramesIn 1.3.6.1.4.1.164.8.12.1.1.10
Number of Bridged frames which were received on this link.
OBJECT-TYPE    
  Counter32  

pktSwchEthernetLinkBridgFramesOut 1.3.6.1.4.1.164.8.12.1.1.11
Number of Bridged frames which were transmitted from this link.
OBJECT-TYPE    
  Counter32  

pktSwchEthernetLinkDiscardedByFilter 1.3.6.1.4.1.164.8.12.1.1.12
Number of Bridged frames which were received on this link.
OBJECT-TYPE    
  Counter32  

pktSwchEthernetFilterTable 1.3.6.1.4.1.164.8.12.2
The Ethernet filter table defines the frame filtering and routing through the PS Ethernet links.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchEthernetFilterEntry

pktSwchEthernetFilterEntry 1.3.6.1.4.1.164.8.12.2.1
The Ethernet Filter Entry defines the filtering on each Ethernet link. The filter entry is operational only if Bridging Handling is enabled and there is no point to point destination configured for this link. If there is a point to point destination configured, the frames will be directed to this destination.
OBJECT-TYPE    
  PktSwchEthernetFilterEntry  

pktSwchEthernetFilterId 1.3.6.1.4.1.164.8.12.2.1.1
Identification Number of an entry in the filter table. The ID together with the ifindex define an entry.
OBJECT-TYPE    
  Integer32 1..10  

pktSwchEthernetFilterMacAddr 1.3.6.1.4.1.164.8.12.2.1.2
This parameter defines the MAC address in the current entry of the filter table. The MAC address in the filter table is compared with the MAC address in the received frame. If the MAC address and protocol type of the frame are equal to the values in the filter table, the frame will be directed to the destination address specified in the filter table. Possible values: MAC Address : 6 sets of 2 Hexadecimal digits with spaces between them (XX XX XX XX XX XX) Broadcasting: FF FF FF FF FF FF Don't Care : 00 00 00 00 00 00 For Broadcasting: If a broadcasting entry contains a destination, the frame will not be broadcasted. It will be directed to the destination in this entry. For Don't care: The MAC address in the frame and in the filter table are not compared. The frames will be directed to the destination specified in the filter table if there is a match between the protocol types in the frame and in the filter table. Default value: 00 00 00 00 00 00
OBJECT-TYPE    
  OCTET STRING SIZE(6)  

pktSwchEthernetFilterProtType 1.3.6.1.4.1.164.8.12.2.1.3
The protocol type which is compared with the protocol type in the received frame. Each protocol in the IP frame is assigned 16 bits (see RFC1700.txt on the assignment of protocol parameters for the Internet protocol suite.). If 65535 is entered for the protocol, it means Don't Care. If there is a match between this protocol and the protocol in the received frame and a match in the MAC addresses, the frame will be directed to the destination specified in this table. Default value: dontCare (65535).
OBJECT-TYPE    
  INTEGER llc(256), ip(2048), arp(2054), appleTalk(32923), dontCare(65535)  

pktSwchEthernetFilterDest 1.3.6.1.4.1.164.8.12.2.1.4
Destination of the frames which match this current entry. The match is in the MAC address and protocol. Possible values: X.25 PVC: Port:LCN X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID number Frame Relay: Port:DLCI No Destination: None If No Destination, the frames will be discarded. Default value: None .
OBJECT-TYPE    
  DisplayString  

pktSwchEthernetFilterStatus 1.3.6.1.4.1.164.8.12.2.1.5
The status of this filter table entry. valid - This entry was saved. createRequest - Request to create a new entry. underCreation - For a new/updated entry. invalid - Entry is deleted.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchEthernetBridging 1.3.6.1.4.1.164.8.12.3
OBJECT IDENTIFIER    

pktSwchEthernetBridgingWanToWan 1.3.6.1.4.1.164.8.12.3.1
Enable/Disable Ethernet Bridging, WAN to WAN.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

pktSwchEthernetBridgingTimer 1.3.6.1.4.1.164.8.12.3.2
Timer used for WAN to WAN communication in order to prevent broadcast frames looping forever between devices. When the timer expires, the frames are discarded. Possible values: 0 - No timer is used. 1..255 - Timer value in units of 100 mili sec.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchEthernetBridgingStatus 1.3.6.1.4.1.164.8.12.3.3
The status of the Ethernet Bridging Parameters. valid - This table was saved. underCreation - The table was updated and not yet saved.
OBJECT-TYPE    
  INTEGER valid(1), underCreation(3)  

pktSwchEthernetBroadcastDestTable 1.3.6.1.4.1.164.8.12.4
The Ethernet Broadcast Destination table defines all the Bridging destinations of the PS. Each Broadcasted frame will be broadcasted to all these destinations.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchEthernetBroadcastDestEntry

pktSwchEthernetBroadcastDestEntry 1.3.6.1.4.1.164.8.12.4.1
The Ethernet Broadcast Entry defines destinations for Ethernet bridge data.
OBJECT-TYPE    
  PktSwchEthernetBroadcastDestEntry  

pktSwchEthernetBroadcastDestProtocol 1.3.6.1.4.1.164.8.12.4.1.1
The protocol of the Broadcasted frames.
OBJECT-TYPE    
  INTEGER x25(2), frameRelay(3)  

pktSwchEthernetBroadcastDestId 1.3.6.1.4.1.164.8.12.4.1.2
Identification Number of an entry in the Ethernet Broadcast Destination table.
OBJECT-TYPE    
  Integer32 1..10  

pktSwchEthernetBroadcastDestDestination 1.3.6.1.4.1.164.8.12.4.1.3
Destination for the Ethernet frames. Possible values for X25: X.25 PVC: Port:LCN X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID number Possible values for fr: Frame Relay: Port:DLCI No Destination: None
OBJECT-TYPE    
  DisplayString  

pktSwchEthernetBroadcastDestStatus 1.3.6.1.4.1.164.8.12.4.1.4
The status of this Ethernet Destination table entry. valid - This entry was saved. createRequest - Request to create a new entry. underCreation - For a new/updated entry. invalid - Entry is deleted.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchIp 1.3.6.1.4.1.164.8.13
OBJECT IDENTIFIER    

pktSwchIpGlobal 1.3.6.1.4.1.164.8.13.1
OBJECT IDENTIFIER    

pktSwchIpGlobalMaxHopCount 1.3.6.1.4.1.164.8.13.1.1
Maximum no. of hops the device will support. The default value is 15. Legal values: 5 to 65000.
OBJECT-TYPE    
  Integer32 5..65000  

pktSwchIpIntervalBetweenUpdates 1.3.6.1.4.1.164.8.13.1.2
The time in seconds from one update of the device's dynamic routing table to the next update. The time is in steps of 10 seconds. Default value: 30 Legal values: 30,40,50 ... 2550
OBJECT-TYPE    
  Integer32 30..2550  

pktSwchIpGlobalStatus 1.3.6.1.4.1.164.8.13.1.3
The status of this IP Global entry. Used for saving the IP Global parameters.
OBJECT-TYPE    
  INTEGER valid(1), underCreation(3)  

pktSwchIpInterfaceTable 1.3.6.1.4.1.164.8.13.2
The Ip interface table defines the Ip interfaces and their parameters in the PS device.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchIpInterfaceEntry

pktSwchIpInterfaceEntry 1.3.6.1.4.1.164.8.13.2.1
The IP interface Entry defines the IP configuration parameters for each IP interface.
OBJECT-TYPE    
  PktSwchIpInterfaceEntry  

pktSwchIpInterfaceId 1.3.6.1.4.1.164.8.13.2.1.1
Identification Number of an entry in the IP interface table.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchIpInterfaceAddress 1.3.6.1.4.1.164.8.13.2.1.2
The IP address of the interface. Legal input: any legal IP address. Default value: 0.0.0.0
OBJECT-TYPE    
  IpAddress  

pktSwchIpInterfaceAddressMask 1.3.6.1.4.1.164.8.13.2.1.3
The IP mask of the interface. Legal input: any legal IP mask: A string of the format X.X.X.X where every X is a number in the range 0-255. Default value: 255.255.255.255
OBJECT-TYPE    
  IpAddress  

pktSwchIpInterfaceSendDefRoutMsgOnly 1.3.6.1.4.1.164.8.13.2.1.4
Some of the RIP messages are default router messages. These messages inform who the default router is. This MIB object allows the user to configure the device so that it will send default router messages only. If sendDefaultRoutMsgOnly is set to enable, the device will not send any RIP messages except for default router messages. Default value: disable .
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

pktSwchIpInterfaceDest 1.3.6.1.4.1.164.8.13.2.1.5
Destination of the packets received on this interface. Possible values: X.25 PVC: Port:LCN X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID number. Frame Relay: Port:DLCI HDLC: 'H' followed by the HDLC Port Number SLIP: 'S' followed by the SLIP Channel Number Ethernet: 'E' followed by the Ethernet Port Number PPP: 'P' followed by the PPP Port Number. Bundles(for PPP)'B' followed by the PPP Bundle Number. No destination: None Default : None Examples: 1. For SLIP destination which is Link no. 1, the destination will be S100 (100 instead of 1 is for Async). 2. For SLIP destination of APS-8, channel no. 8: S8 3. For PPP destination of APS-8, Sync Link no. 1: P1 4. For PPP destination of APS-8, Async channel on link 1: P100 Note for PPP: PPP protocol is allowed to be applied on Sync Links (1-3) as well as Async channels (1-24). In the ascii terminal: If the user writes P1 for example the device has to check which P1 it is. Is it the async channel 1 or Link no. 1. The device does NOT ALLOW configuring PPP on both Sync Link no. 1 and async RJ45 channel 1. When P1 is entered by the user, the protocols on async channel 1 and sync link 1 are checked. As only one of them is PPP, it will apply to the only PPP chan/link.
OBJECT-TYPE    
  DisplayString  

pktSwchIpInterfaceInactivity 1.3.6.1.4.1.164.8.13.2.1.6
Inactivity time in minutes before disconnecting the X25 SVC call. Range: 0..255. Default: 2.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchIpInterfaceLinkCost 1.3.6.1.4.1.164.8.13.2.1.7
This value will be added to the value written in the metric field of the received frame. Range: 1..pktSwchIpGlobalMaxHopCount Default: 1.
OBJECT-TYPE    
  Integer32  

pktSwchIpInterfaceOptions 1.3.6.1.4.1.164.8.13.2.1.8
When netIpAddress is selected the interface IP address will not be the IP address of the interface. It will be the IP address of the NetWork which is connected to this interface. This option is for an interface which does not require a unique IP address. Default is none.
OBJECT-TYPE    
  INTEGER netIpAddress(2), none(255)  

pktSwchIpInterfaceStatus 1.3.6.1.4.1.164.8.13.2.1.9
The status of this filter table entry. valid - This entry was saved. createRequest - Request to create a new entry. underCreation - For a new/updated entry. invalid - Entry is deleted.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchIpInterfaceRxFrames 1.3.6.1.4.1.164.8.13.2.1.10
No. of frames which were received on this IP interface.
OBJECT-TYPE    
  Counter32  

pktSwchIpInterfaceRxExpiredTtl 1.3.6.1.4.1.164.8.13.2.1.11
No. of frames which were received on this IP interface with an Expired Time to Live value.
OBJECT-TYPE    
  Counter32  

pktSwchIpInterfaceRxUnknownDest 1.3.6.1.4.1.164.8.13.2.1.12
No. of frames which were received on this IP interface with an unknown IP destination. No default router is configured. These frames will be discarded.
OBJECT-TYPE    
  Counter32  

pktSwchIpInterfaceTxFrames 1.3.6.1.4.1.164.8.13.2.1.13
No. of frames which were Transmitted from this IP interface.
OBJECT-TYPE    
  Counter32  

pktSwchIpInterfaceTxQueueBufs 1.3.6.1.4.1.164.8.13.2.1.14
No. of buffers which are waiting in the Trasnsmit Queue.
OBJECT-TYPE    
  Counter32  

pktSwchIpInterfaceTxDiscarded 1.3.6.1.4.1.164.8.13.2.1.15
No. of frames which were ready to be transmitted but were Discarded. The PS will discard frames if the transmit queue is too long.
OBJECT-TYPE    
  Counter32  

pktSwchIpInterfaceRipRxFrames 1.3.6.1.4.1.164.8.13.2.1.16
No. of RIP frames which were received on this IP interface.
OBJECT-TYPE    
  Counter32  

pktSwchIpInterfaceRipTxFrames 1.3.6.1.4.1.164.8.13.2.1.17
No. of RIP Frames which were transmitted from this IP interface.
OBJECT-TYPE    
  Counter32  

pktSwchIpInterfaceRipWaitingMsgs 1.3.6.1.4.1.164.8.13.2.1.18
No. of RIP messages which are waiting to be transmitted to the Network.
OBJECT-TYPE    
  Counter32  

pktSwchIsdn 1.3.6.1.4.1.164.8.14
OBJECT IDENTIFIER    

pktSwchIsdnGlobal 1.3.6.1.4.1.164.8.14.1
OBJECT IDENTIFIER    

pktSwchIsdnGlobalCallRetries 1.3.6.1.4.1.164.8.14.1.1
Number of times the call request is repeated after failure. Possible values: 0 - Disable retry mechanism 1-255 - Number of retries default value: 0
OBJECT-TYPE    
  Integer32 0..255  

pktSwchIsdnGlobalCallRetryDelay 1.3.6.1.4.1.164.8.14.1.2
Time interval between retries (in seconds). Possible values: 5 - 250 Default value: 15
OBJECT-TYPE    
  Integer32 5..250  

pktSwchIsdnGlobalCallinactivity 1.3.6.1.4.1.164.8.14.1.3
Time of inactivity in seconds, after which the call will be disconnected. An x.25 link is considered inactive when there are no open calls on the link. A frame relay link is considered inactive when there is no traffic on the link. Possible values: 0 - No disconnection on inactivity. 1 - 65000 - Time period (in seconds). Default value: 180
OBJECT-TYPE    
  Integer32 0..65000  

pktSwchIsdnGlobalStatus 1.3.6.1.4.1.164.8.14.1.4
The status of the Isdn Global parameters. Used for saving the Isdn global parameters.
OBJECT-TYPE    
  INTEGER valid(1), underCreation(3)  

pktSwchIsdnRoutTable 1.3.6.1.4.1.164.8.14.2
The Isdn Routing Table entries in the Packet Switch.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchIsdnRoutEntry

pktSwchIsdnRoutEntry 1.3.6.1.4.1.164.8.14.2.1
Isdn Routing Entry defines the contents of each entry in the table. The outgoing addresses are in a different table - pktSwchIsdnRoutAddrTable. The row status in this table will be used for both tables.
OBJECT-TYPE    
  PktSwchIsdnRoutEntry  

pktSwchIsdnRoutId 1.3.6.1.4.1.164.8.14.2.1.1
Number of this routing entry.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchIsdnRoutDataBandWidth 1.3.6.1.4.1.164.8.14.2.1.2
Isdn Bandwidth which will be used for the data routed via this entry. The ISDN interface will be configured with the speed which is selected. Possible values: 2 - 56 Kbps. 3 - 64 Kbps. Default value: 3
OBJECT-TYPE    
  INTEGER bw56Kbps(2), bw64Kbps(3)  

pktSwchIsdnRoutOptions 1.3.6.1.4.1.164.8.14.2.1.3
Special Options for this routing entry. Possible values: 1 - No special options. 2 - Return to main link. This option is used when the current link is defined as a backup link and the main link becomes active. Default value: 1
OBJECT-TYPE    
  INTEGER noOptions(1), returnToMainLink(2)  

pktSwchIsdnRoutStatus 1.3.6.1.4.1.164.8.14.2.1.4
The status of this routing table entry + address table (pktSwchIsdnOutAddrTable). For creating a new entry select createRequest. A new route entry will be created together with an out address entry. There may be more than 1 addresses. For example, if there is 1 outgoing address and 2 alternatives, the new address entry will have 3 indices. For deleting an entry select invalid. The relevant address entry should be deleted too. For saving an entry select valid. Save should include the addresses of the current entry in the pktSwchIsdnOutAddrTable
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchIsdnOutAddrTable 1.3.6.1.4.1.164.8.14.3
Outgoing ISDN addresses used by the ISDN routing table. The address table contains outgoing addresses and alternative addresses in case the connection to the first addresses does not succeed.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchIsdnOutAddrEntry

pktSwchIsdnOutAddrEntry 1.3.6.1.4.1.164.8.14.3.1
Isdn Outgoing Address Entry defines the contents of each entry in the outgoing address table. Each entry has 2 indices: 1. RoutId is the ID in the routing table. 2. AddrId is the ID containing the Outgoing address and sub address.
OBJECT-TYPE    
  PktSwchIsdnOutAddrEntry  

pktSwchIsdnOutAddrRoutId 1.3.6.1.4.1.164.8.14.3.1.1
ID in the ISDN routing table.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchIsdnOutAddrId 1.3.6.1.4.1.164.8.14.3.1.2
Number of the address + subaddress pair for each routing ID.
OBJECT-TYPE    
  Integer32 1..3  

pktSwchIsdnOutAddr 1.3.6.1.4.1.164.8.14.3.1.3
Destination ISDN Outgoing (Remote) address. The data will be routed out to this address. Possible values: Up to 17 decimal digits. Default value: string of length 0.
OBJECT-TYPE    
  DisplayString SIZE(0..17)  

pktSwchIsdnOutSubAddr 1.3.6.1.4.1.164.8.14.3.1.4
Destination ISDN Outgoing (Remote) sub address. The data will be routed out to the out addrress with this sub address. Possible values: Up to 6 decimal digits. Default value: string of length 0.
OBJECT-TYPE    
  DisplayString SIZE(0..6)  

pktSwchIsdnAcceptTable 1.3.6.1.4.1.164.8.14.4
Table of Isdn addresses which will be accepted by the agent. If there is a dial back (answer) address, the incoming call will be disconnected and dial back will initiate. Most of the accept list parameters are in RFC2128 in the dialCtlPeerCfgTable. The parameters which are not in the the standard RFC2128 and are required, are defined here in the private PS MIB.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchIsdnAcceptEntry

pktSwchIsdnAcceptEntry 1.3.6.1.4.1.164.8.14.4.1
Isdn Accept Entry defines the contents of each entry in the table.
OBJECT-TYPE    
  PktSwchIsdnAcceptEntry  

pktSwchIsdnAcceptId 1.3.6.1.4.1.164.8.14.4.1.1
Identifier of Accept table entry.
OBJECT-TYPE    
  Integer32 1..200  


pktSwchIsdnAcceptDialbkSubAddress 1.3.6.1.4.1.164.8.14.4.1.3
Isdn sub address which will be used by the agent for dialing back. Possible values: Up to 6 decimal digits. Default value: string of length 0.
OBJECT-TYPE    
  DisplayString SIZE(0..6)  

pktSwchIsdnAcceptStatus 1.3.6.1.4.1.164.8.14.4.1.4
The status of this accept table entry. For creating a new entry select createRequest, For deleting an entry select invalid. For saving an entry select valid.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchIsdnLinkTable 1.3.6.1.4.1.164.8.14.5
Table of Isdn Link parameters. Most of the link parameters are in in RFC2127. Isdn Call statistics are RFC2128. The parameters which are not in the the standard RFCs , and are required, are defined here in the private PS MIB.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchIsdnLinkEntry

pktSwchIsdnLinkEntry 1.3.6.1.4.1.164.8.14.5.1
Isdn Link Entry defines the contents of each entry in the table.
OBJECT-TYPE    
  PktSwchIsdnLinkEntry  

pktSwchIsdnLinkBchannel 1.3.6.1.4.1.164.8.14.5.1.1
Defines which B channels are used for Leased Lines Only. Default value: noBchannel(1).
OBJECT-TYPE    
  INTEGER noBchannel(1), b1(2), b2(3), b1Andb2(4)  

pktSwchIsdnCallsClrs 1.3.6.1.4.1.164.8.14.5.1.2
Number of calls on this link which were cleared since the link was activated.
OBJECT-TYPE    
  Counter32  

pktSwchIsdnTestCmd 1.3.6.1.4.1.164.8.14.5.1.3
Activate/Stop an ISDN test on the current ISDN link. In order to Activate the test, set the TestCmd to 3 (activate). For stopping the test, set the TestCmd to 2 (noOp). Important: In order for the test to succeed, the user must set the pktSwchIsdnTestAddr and Subaddr to their required values before activating the test.
OBJECT-TYPE    
  INTEGER noOp(2), activate(3)  

pktSwchIsdnTestAddr 1.3.6.1.4.1.164.8.14.5.1.4
Destination ISDN Outgoing (Remote) address which will be called in order to test the ISDN. Possible values: Up to 17 decimal digits. Default value: string of length 0. Important: In order for the test to succeed, the user must also set the pktSwchIsdnTestSubAddr to the required values before activating the test.
OBJECT-TYPE    
  DisplayString SIZE(0..17)  

pktSwchIsdnTestSubAddr 1.3.6.1.4.1.164.8.14.5.1.5
Destination ISDN Outgoing (Remote) address which will be called in order to test the ISDN. Possible values: Up to 6 decimal digits. Default value: string of length 0. Important: In order for the test to succeed, the user must also set the pktSwchIsdnTestAddr to the required values before activating the test.
OBJECT-TYPE    
  DisplayString SIZE(0..6)  

pktSwchPpp 1.3.6.1.4.1.164.8.15
OBJECT IDENTIFIER    

pktSwchPppSecretsTable 1.3.6.1.4.1.164.8.15.1
Table of PPP Secret parameters. The parameters are defined in rfc1472 except for the ROW status which is defined here. In the standard, there is no create request option, so in order to be consistent with other ROW statuses in the Packet Switches it is defined here.
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchPppSecretsEntry

pktSwchPppSecretsEntry 1.3.6.1.4.1.164.8.15.1.1
PPP Secrets Entry defines the contents of each entry in the table.
OBJECT-TYPE    
  PktSwchPppSecretsEntry  

pktSwchPppSecretsPairId 1.3.6.1.4.1.164.8.15.1.1.1
Index of the Secrets Pair.
OBJECT-TYPE    
  Integer32 1..200  

pktSwchPppSecretsStatus 1.3.6.1.4.1.164.8.15.1.1.2
The status of the PPP Secrets table. For creating a new entry select createRequest, For deleting an entry select invalid. For saving an entry select valid.
OBJECT-TYPE    
  INTEGER valid(1), createRequest(2), underCreation(3), invalid(4)  

pktSwchPppChanTable 1.3.6.1.4.1.164.8.15.2
Table of PPP Channel parameters. The table can be used for Async as well as Sync parameters. In case a parameter is irrelevant for Async or Sync a value may be returned. Statistics Parameters are already defined in rfc1213: ifInUcastPkts, ifOutUcastPkts, ifInErrors, ifOutErrors
OBJECT-TYPE    
  SEQUENCE OF  
    PktSwchPppChanEntry

pktSwchPppChanEntry 1.3.6.1.4.1.164.8.15.2.1
PPP Channel Entry defines the contents of each entry in the table.
OBJECT-TYPE    
  PktSwchPppChanEntry  

pktSwchPppChanSpeed 1.3.6.1.4.1.164.8.15.2.1.1
The port's speed in bits per second. For Async channels: Default value: 14 . For Sync Links: Use not_applicable(255) The Sync Links have an internal clock with different values.
OBJECT-TYPE    
  INTEGER s110bps(1), s300bps(2), s1200bps(3), s600bps(4), s75bps(5), s150bps(6), s2400bps(12), s4800bps(13), s9600bps(14), s19200bps(15), s38400bps(19), s57600bps(20), s115200bps(21), notApplicable(255)  

pktSwchPppChanFlowCtlDuration 1.3.6.1.4.1.164.8.15.2.1.2
Hardware Flow Control Duration. 1..254 - Duration (in 50ms intervals). when timer expires, flow control stops. 0 - No Hardware flow control. 255 - Continuous Flow Control. Default value: 0. For Sync Links, return 0.
OBJECT-TYPE    
  Integer32 0..255  

pktSwchPppChanStopBits 1.3.6.1.4.1.164.8.15.2.1.3
This entry indicates the number of stop bits per character. The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits. For Sync Links: notApplicable(255).
OBJECT-TYPE    
  INTEGER one(1), two(2), oneAndHalf(3), notApplicable(255)  

pktSwchPppChanBitPerChar 1.3.6.1.4.1.164.8.15.2.1.4
The number of data bits per character supported by the ppp link. Legal values for Async channels: 5..8 . For Sync Links: 0
OBJECT-TYPE    
  Integer32 0..8  

pktSwchPppChanParity 1.3.6.1.4.1.164.8.15.2.1.5
This entry selects the type of parity to be checked or generated. The options are (1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity. For Sync Links: none(255).
OBJECT-TYPE    
  INTEGER space(1), mark(2), even(3), odd(4), none(255)  

pktSwchPppChanNegotiationTrigger 1.3.6.1.4.1.164.8.15.2.1.6
The trigger which is used in order to start the Negotiation. The HW signals which are used are: DCD (Data Carrier Detect) - issued by DCE DSR (Data Set Ready) - issued by DCE DTR (Data Terminal Ready) - issued by DTE 1 - Start negotiation on signal assertion. The Peer will issue a DCD/DSR Signal if it is DCE or DTR if it is DTE. If the current channel/link is DCE, it will check the DTR. If the current channel/link is DTE, it will check the DCD/DSR. When the HW signal is issued, negotiation will begin. 2 - Data Triggered. The current channel/link will issue a HW signal. Negotiation will begin when data is received. 3 - Combination of option 1 and option 2. 255 - Starts negotiation after reset. Ignore HW signals. Default Value for Async Channel: 255. Default Value for Sync Link: 3
OBJECT-TYPE    
  INTEGER hw-signal(1), data-triggered(2), hw-signal-or-data(3), after-reset(255)  

pktSwchPppChanMRU 1.3.6.1.4.1.164.8.15.2.1.7
Maximum Receive Unit. Size of the packet which is negotiated with the connected device. Default value: 1500 .
OBJECT-TYPE    
  Integer32 1500..4096  

pktSwchPppChanACCM 1.3.6.1.4.1.164.8.15.2.1.8
Async Control Character Map - The ACCM value serves as a mask for the first 32 characters in the ASCII table. Control characters may cause problems when they are transferred on the network. This can be handled by escaping them ( adding escape character to them ). For example , when using modems in the network which can not receive X-on and X-off characters. The ACCM is a mask which shows which control characters will be handled with an escape sequence. Each bit represents one character. Possible values: Octet string of 4 bytes: 00000000 . A bit with value 1 will cause the character to be in an escape sequence. 0 will leave the character as it is. Example : to use XON and XOFF as escape sequence : 000A0000 Default value: 00000000. For Sync Links return the default.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

pktSwchPppChanAuthentication 1.3.6.1.4.1.164.8.15.2.1.9
Port Authentication Type. 1 - No Authentication: User side Only. 2 - Configuration of the Host side. PAP (Password Authentication Protocol) or CHAP (Challenge Handshake Authentication Protocol) will be accepted by the current host. 3 - Configuration of the host side as CHAP only. Only CHAP will be accepted by the current host. Default value: 1 .
OBJECT-TYPE    
  INTEGER no-authentication(1), pap-or-chap(2), chap-only(3)  

pktSwchPppChanInternalClock 1.3.6.1.4.1.164.8.15.2.1.10
The internal clock rate of the MLPPP Link. Default value: 9. For Async channels: return 255.
OBJECT-TYPE    
  INTEGER r3000bps(1), r4800bps(2), r9600bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps(7), r56Kbps(8), r64Kbps(9), r128Kbps(10), r256Kbps(11), r384Kbps(12), r512Kbps(13), r768Kbps(14), r1024Kbps(15), r1445Kbps(16), r2048Kbps(17), external(255)  

pktSwchPppChanBundle 1.3.6.1.4.1.164.8.15.2.1.11
Bundle Number. It is possible to attach a few channels/links to a bundle. If the User enters a non existing bundle number, the PS will create a new bundle with this number. The bundle number may be: 1..255 If the bundle number is 0 it means: do not attach to bundle. Default value: 0 .
OBJECT-TYPE    
  Integer32 0..255  

pktSwchpPppChanIsdnRoutId 1.3.6.1.4.1.164.8.15.2.1.12
ISDN destination. ID (1..200) in the ISDN routing table containing the outgoing ISDN address for this channel/link. For no destination: 0 Default value: 0
OBJECT-TYPE    
  Integer32 0..200  

pktSwchpPppChanLastEvent 1.3.6.1.4.1.164.8.15.2.1.13
Status showing the last PPP event which occured on the line described in an ascii string. Examples: 1. Received Configuration Request. 2. Sent Protocol Reject. 3. Error: Can Not Compress Frame. Default: 0 for no last event on this link or channel.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

radEthRptr 1.3.6.1.4.1.164.9
OBJECT IDENTIFIER    

radEthRptrEvents 1.3.6.1.4.1.164.9.0
The events for Ethernet Repeater.
OBJECT-IDENTITY    

etRptrHealth 1.3.6.1.4.1.164.9.0.1
The etRptrHealth trap conveys information related to the operational status of the repeater. This trap is sent either when the value of etRptrOperStatus changes, or upon completion of a non-disruptive test. See the etRptrOperStatus object for descriptions of the information that is sent. The agent must throttle the generation of consecutive etRptrHealth traps so that there is at least a five-second gap between traps of this type. When traps are throttled, they are dropped, not queued for sending at a future time. (Note that 'generating' a trap means sending to all configured recipients.)
NOTIFICATION-TYPE    
  etRptrOperStatus  
  rptrGroupOperStatus  
  agnLed  

etRptrResetEvent 1.3.6.1.4.1.164.9.0.2
The etRptrResetEvent trap conveys information related to the operational status of the repeater. This trap is sent on completion of a repeater reset action. A repeater reset action is defined as an a transition to the START state of Fig 9-2 in section 9 [IEEE 802.3 Std], when triggered by a management command (e.g., an SNMP Set on the etRptrReset object). The agent must throttle the generation of consecutive etRptrResetEvent traps so that there is at least a five-second gap between traps of this type. When traps are throttled, they are dropped, not queued for sending at a future time. (Note that 'generating' a trap means sending to all configured recipients.) The etRptrResetEvent trap is not sent when the agent restarts and sends an SNMP coldStart or warmStart trap. However, it is recommended that a repeater agent send the etRptrOperStatus object as an optional object with its coldStart and warmStart trap PDUs. The etRptrOperStatus object must be included in the varbind list sent with this trap. The agent may optionally include the etRptrHealthText object as well.
NOTIFICATION-TYPE    
  etRptrOperStatus  
  etRptrIndex  
  agnLed  

etRptrConfig 1.3.6.1.4.1.164.9.0.3
This trap is sent upon every change of the etRptrMdlVector object.
NOTIFICATION-TYPE    
  etRptrMdlVector  
  agnLed  

etRptrTable 1.3.6.1.4.1.164.9.1
This table contains repeater data specific to the etRptrIndex.
OBJECT-TYPE    
  SEQUENCE OF  
    EtRptrEntry

etRptrEntry 1.3.6.1.4.1.164.9.1.1
An entry in table etRptrTable.
OBJECT-TYPE    
  EtRptrEntry  

etRptrIndex 1.3.6.1.4.1.164.9.1.1.1
The Repeater Id, this table data refer to.
OBJECT-TYPE    
  Integer32  

etRptrGroupCapacity 1.3.6.1.4.1.164.9.1.1.2
The etRptrGroupCapacity is the number of groups that can be contained within the repeater. Within each managed repeater, the groups are uniquely numbered in the range from 1 to etRptrGroupCapacity. Some groups may not be present in the repeater, in which case the actual number of groups present will be less than etRptrGroupCapacity. The number of groups present will never be greater than etRptrGroupCapacity. Note: In practice, this will generally be the number of field-replaceable units (i.e., modules, cards, or boards) that can fit in the physical repeater enclosure, and the group numbers will correspond to numbers marked on the physical enclosure.
OBJECT-TYPE    
  Integer32 1..1024  

etRptrOperStatus 1.3.6.1.4.1.164.9.1.1.3
The etRptrOperStatus object indicates the operational state of the repeater. The etRptrHealthText object may be consulted for more specific information about the state of the repeater's health. In the case of multiple kinds of failures (e.g., repeater failure and port failure), the value of this attribute shall reflect the highest priority failure in the following order, listed highest priority first: rptrFailure(3) groupFailure(4) portFailure(5) generalFailure(6).
OBJECT-TYPE    
  INTEGER other(1), ok(2), rptrFailure(3), groupFailure(4), portFailure(5), generalFailure(6)  

etRptrHealthText 1.3.6.1.4.1.164.9.1.1.4
The health text object is a text string that provides information relevant to the operational state of the repeater. Agents may use this string to provide detailed information on current failures, including how they were detected, and/or instructions for problem resolution. The contents are agent-specific.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

etRptrReset 1.3.6.1.4.1.164.9.1.1.5
Setting this object to reset(2) causes a transition to the START state of Fig 9-2 in section 9 [IEEE 802.3 Std]. Setting this object to noReset(1) has no effect. The agent will always return the value noReset(1) when this object is read. After receiving a request to set this variable to resetHW(2), the agent is allowed to delay the reset for a short period. For example, the implementor may choose to delay the reset long enough to allow the SNMP response to be transmitted. In any event, the SNMP response must be transmitted. This action does not reset the management counters defined in this document nor does it affect the portAdminStatus parameters. Included in this action is the execution of a disruptive Self-Test with the following characteristics: a) The nature of the tests is not specified. b) The test resets the repeater but without affecting management information about the repeater. c) The test does not inject packets onto any segment. d) Packets received during the test may or may not be transferred. e) The test does not interfere with management functions. After performing this self-test, the agent will update the repeater health information (including etRptrOperStatus and etRptrHealthText), and send a etRptrHealth trap. Setting this object to resetConfig(3) will cause resetting the repeater to its default values.
OBJECT-TYPE    
  INTEGER noReset(1), resetHW(2), resetConfig(3)  

etRptrNonDisruptTest 1.3.6.1.4.1.164.9.1.1.6
Setting this object to selfTest(2) causes the repeater to perform a agent-specific, non- disruptive self-test that has the following characteristics: a) The nature of the tests is not specified. b) The test does not change the state of the repeater or management information about the repeater. c) The test does not inject packets onto any segment. d) The test does not prevent the relay of any packets. e) The test does not interfere with management functions. After performing this test, the agent will update the repeater health information (including etRptrOperStatus and etRptrHealthText) and send a etRptrHealth trap. Note that this definition allows returning an 'okay' result after doing a trivial test. Setting this object to noSelfTest(1) has no effect. The agent will always return the value noSelfTest(1) when this object is read.
OBJECT-TYPE    
  INTEGER noSelfTest(1), selfTest(2)  

etRptrTotalPartitionedPorts 1.3.6.1.4.1.164.9.1.1.7
This object returns the total number of ports in the repeater whose current state meets all three of the following criteria: etRptrPortOperStatus does not have the value notPresent(3), etRptrPortAdminStatus is enabled(1), and etRptrPortAutoPartitionState is autoPartitioned(2).
OBJECT-TYPE    
  Gauge32  

etRptrMdlVector 1.3.6.1.4.1.164.9.1.1.8
This object returns a vector mapping the location of the repeater modules to their corresponding bit position. A bit that is set indicates an existing module
OBJECT-TYPE    
  Integer32  

etRptrMonitorTransmitCollisions 1.3.6.1.4.1.164.9.1.1.9
This counter is incremented every time the repeater state machine enters the TRANSMIT COLLISION state from any state other than ONE PORT LEFT (Ref: Fig 9-2, IEEE 802.3 Std). The approximate minimum time for rollover of this counter is 16 hours.
OBJECT-TYPE    
  Counter32  

etRptrSecTable 1.3.6.1.4.1.164.9.2
Repeater Security Table
OBJECT-TYPE    
  SEQUENCE OF  
    EtRptrSecEntry

etRptrSecEntry 1.3.6.1.4.1.164.9.2.1
An entry in table etRptrSecTable.
OBJECT-TYPE    
  EtRptrSecEntry  

etRptrId 1.3.6.1.4.1.164.9.2.1.1
The Repeater Id, this table data refer to.
OBJECT-TYPE    
  Integer32  

etRptrSecID 1.3.6.1.4.1.164.9.2.1.2
Segment's security unique identification number
OBJECT-TYPE    
  Integer32 1..3  

etRptrSecEnable 1.3.6.1.4.1.164.9.2.1.3
This entry indicates whether the specific segment's security is active or not
OBJECT-TYPE    
  INTEGER off(2), on(3)  

etRptrSecPattern 1.3.6.1.4.1.164.9.2.1.4
A six-octet(48 bit) pattern: where the masked bits of etRptrSecMask need to match the MAC address of each port within the segment.Value of all zeros indicates no security.
OBJECT-TYPE    
  OCTET STRING  

etRptrSecMask 1.3.6.1.4.1.164.9.2.1.5
Mask of the allowed MAC address that can be connected through the ports within the segment
OBJECT-TYPE    
  OCTET STRING  

radRouter 1.3.6.1.4.1.164.11
OBJECT IDENTIFIER    

rtrBridge 1.3.6.1.4.1.164.11.7
OBJECT IDENTIFIER    

radAtm 1.3.6.1.4.1.164.12
OBJECT IDENTIFIER    

atmNte 1.3.6.1.4.1.164.12.3
OBJECT IDENTIFIER    

atmNteEvents 1.3.6.1.4.1.164.12.3.0
The events for RAD ATM products.
OBJECT-IDENTITY    

atmNtePrt 1.3.6.1.4.1.164.12.3.2
OBJECT IDENTIFIER    

atmNtePrtConfig 1.3.6.1.4.1.164.12.3.2.1
OBJECT IDENTIFIER    

atmNteConfIfTable 1.3.6.1.4.1.164.12.3.2.1.1
The Physical interface configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteConfIfEntry

atmNteConfIfEntry 1.3.6.1.4.1.164.12.3.2.1.1.1
An entry in the Physical interface configuration table. The ifIndex is of the lowest physical layer.
OBJECT-TYPE    
  AtmNteConfIfEntry  

atmConfIfTransmitClk 1.3.6.1.4.1.164.12.3.2.1.1.1.1
The transmit clock of the port.
OBJECT-TYPE    
  INTEGER internal(2), external(3), loopback(4), adaptive(5)  

atmConfIfLoopback 1.3.6.1.4.1.164.12.3.2.1.1.1.2
Interface Loopback.
OBJECT-TYPE    
  INTEGER internal(2), external(3), disable(4)  

atmConfIfFrameType 1.3.6.1.4.1.164.12.3.2.1.1.1.3
The frame type. Valid values for a 155M interface: sonet(2), sdh(3). Valid values for a T3 interface: direct(4), plcpInternal(5), plcpExternal(6), directNoScrmbling(10), plcpInternalNoScrmbling(11), plcpExternalNoScrmbling(12). Valid values for Ethernet interface: ethCrcTrans (8), ethCrcNotTrans(9). (DS1 interfaces frame type is specified in the DSX1 mib).
OBJECT-TYPE    
  INTEGER other(1), sonet(2), sdh(3), direct(4), plcpInternal(5), plcpExternal(6), e3(7), ethCrcTrans(8), ethCrcNotTrans(9), directNoScrmbling(10), plcpInternalNoScrmbling(11), plcpExternalNoScrmbling(12)  

atmConfIfCardType 1.3.6.1.4.1.164.12.3.2.1.1.1.4
The card type.
OBJECT-TYPE    
  INTEGER notApplicable(1), sc13m-155(2), st13s-155(3), st13l-155(4), utp-155(5), cx-bnc-155(6), e3(7), t3(8), e1(9), e1-ltu(10), fc13l-155(11), fc13lh-155(12), fc15lh-155(13), fc13l-e3(14), fc13lh-e3(15), fc15lh-e3(16), fc13l-t3(17), fc13lh-t3(18), fc15lh-t3(19)  

atmConfAtmIfVpiVciLimit 1.3.6.1.4.1.164.12.3.2.1.1.1.5
The limit on the sum of the VPI+VCI bits for this interface.
OBJECT-TYPE    
  INTEGER bits15(2), bits17(3)  

atmConfIfHwFeatures 1.3.6.1.4.1.164.12.3.2.1.1.1.6
HW features command.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmConfIfOutputRate 1.3.6.1.4.1.164.12.3.2.1.1.1.7
This parameter indicates the output rate in cells/sec, which is supported per port. Successfully setting this parameter is dependent on all other ports values calculations, which are described in the NMS SRS.
OBJECT-TYPE    
  Integer32  

atmConfIfInputRate 1.3.6.1.4.1.164.12.3.2.1.1.1.8
This parameter indicates the input rate in cells/sec, which is supported per port. Successfully setting this parameter is dependent on all other ports values calculations, which are described in the NMS SRS.
OBJECT-TYPE    
  Integer32  

atmConfAlarmForwarding 1.3.6.1.4.1.164.12.3.2.1.1.1.9
Enables Path AIS Alarm forwarding upon a failure detection. The following might be considered as a failure: LOS, LOF, LOC, SLM, LOP, Path AIS and Line AIS. disable(2) - will not forward an alarm upon a failure on this port. enable(3) - will forward an alarm upon a failure on this port.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

atmNteAlarmIfTable 1.3.6.1.4.1.164.12.3.2.1.2
The interface Alarm table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteAlarmIfEntry

atmNteAlarmIfEntry 1.3.6.1.4.1.164.12.3.2.1.2.1
An entry in the interface Alarm table.
OBJECT-TYPE    
  AtmNteAlarmIfEntry  

atmInterfaceActiveAlarms 1.3.6.1.4.1.164.12.3.2.1.2.1.1
A Bit String of the active alarms on this interface. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - LOS 2 - LOF 3 - Line AIS (SONET)/ PLCP LOF (DS3) 4 - LOP 5 - Path AIS 6 - SLM 7 - LCD 8 - Line RDI (SONET)/ PLCP Yellow (DS3) 9 - Path RDI (SONET)/ RDI (DS3) 10 - Section BIP (SONET)/ P1/P2 (DS3) > Threshold 11 - Line BIP (SONET)/ PLCP BIP (DS3) > Threshold 12 - Line FEBE (SONET)/ PLCP FEBE (DS3) > Threshold 13 - Path BIP > Threshold 14 - Path FEBE > Threshold 15 - HW Failure
OBJECT-TYPE    
  Integer32  

atmThresholdSectionBIP 1.3.6.1.4.1.164.12.3.2.1.2.1.2
When Section BIPs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface.
OBJECT-TYPE    
  Integer32  

atmThresholdLineBIP 1.3.6.1.4.1.164.12.3.2.1.2.1.3
When Line BIPs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface.
OBJECT-TYPE    
  Integer32  

atmThresholdLineFEBE 1.3.6.1.4.1.164.12.3.2.1.2.1.4
When Line FEBEs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface.
OBJECT-TYPE    
  Integer32  

atmThresholdPathBIP 1.3.6.1.4.1.164.12.3.2.1.2.1.5
When Path BIPs are greater than this threshold, an active alarm is raised.
OBJECT-TYPE    
  Integer32  

atmThresholdPathFEBE 1.3.6.1.4.1.164.12.3.2.1.2.1.6
When Path FEBEs are greater than this threshold, an active alarm is raised.
OBJECT-TYPE    
  Integer32  

atmThresholdErroredCells 1.3.6.1.4.1.164.12.3.2.1.2.1.7
When Errored Cells are greater than this threshold, an active alarm is raised.
OBJECT-TYPE    
  Integer32  

atmThresholdLostCells 1.3.6.1.4.1.164.12.3.2.1.2.1.8
When Lost Cells are greater than this threshold, an active alarm is raised.
OBJECT-TYPE    
  Integer32  

atmThresholdMisinsertedCells 1.3.6.1.4.1.164.12.3.2.1.2.1.9
When Misinserted Cells are greater than this threshold, an active alarm is raised.
OBJECT-TYPE    
  Integer32  

atmInterfaceAlarmStatus 1.3.6.1.4.1.164.12.3.2.1.2.1.10
The variable is on(3) when there is any active alarm on this interface.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmInterfaceMaskAlarms 1.3.6.1.4.1.164.12.3.2.1.2.1.11
A Bit String of alarms mask on this interface. An up bit (1) means that the respective alarm is masked. A down bit (0) means no mask. The mask is supported for the following alarms: 1 - LOS
OBJECT-TYPE    
  Integer32  

atmNteConfVpTable 1.3.6.1.4.1.164.12.3.2.1.3
The ATM VP configuration table. The table is an extension to the atmVplTable of RFC-1695.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteConfVpEntry

atmNteConfVpEntry 1.3.6.1.4.1.164.12.3.2.1.3.1
An entry in the ATM VP configuration table. ifIndex of the ATM layer.
OBJECT-TYPE    
  AtmNteConfVpEntry  

atmConfVpPolicing 1.3.6.1.4.1.164.12.3.2.1.3.1.1
Policing method desired for this VPL.
OBJECT-TYPE    
  INTEGER none(1), police(2), monitor(3), shaping(4), policingAndShaping(5)  

atmConfVpCCAdminStatus 1.3.6.1.4.1.164.12.3.2.1.3.1.2
up(2) - Activate Continuity Check (CC). down(3) - Deactivate CC. source(4) - Activate OAM CC(Continuity Check) of local agent ( start sending Oam cells to the remote side ). sink(5) - Activate CC of remote agent ( start receiving Oam cells from remote side ). listenToActivationCells (6) - Passive listener till gets an activation request originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection.
OBJECT-TYPE    
  INTEGER up(2), down(3), source(4), sink(5), listenToActivationCells(6), originateActivationCells(7)  

atmConfVpLoopbackAdminStatus 1.3.6.1.4.1.164.12.3.2.1.3.1.3
up(2) - Start loopback OAM cells. down(3) - Stop sending loopback OAM cells. For ace2002: up(2) - Transmitting LB cells with llid all ones (i.e. FFFF..FF) down(3) - Not transmitting LB cells. llid(4) - Transmitting LB cells with llid indicated in the address field. segment(5) - Transmitting Segment LB cells with llid all ones. endToEnd(6) - Transmitting End to End LB cells with llid all ones. segmentLlid(7) - Transmitting Segment LB cells with llid indicated in the address field. endToEndLlid(8) - Transmitting LB cells with llid indicated in the address field. This parameter value might be in conflict with atmConfVpOamSupport value, since this parameter is for LB, while atmConfVpOamSupport is for any other OAM cells.
OBJECT-TYPE    
  INTEGER up(2), down(3), llid(4), segment(5), endToEnd(6), segmentLlid(7), endToEndLlid(8)  

atmConfVpLoopbackSinkAddress 1.3.6.1.4.1.164.12.3.2.1.3.1.4
Destination address. For ace101: 2 bytes are used. For ace2002: 16 bytes are used.
OBJECT-TYPE    
  OCTET STRING SIZE(0..20)  

atmConfVpCongestionControl 1.3.6.1.4.1.164.12.3.2.1.3.1.5
Each bit indicates a selection of one option as the following description. All combinations are possible and legal. The codes are: 1 - EPD 2 - CLP 4 - EFCI
OBJECT-TYPE    
  OCTET STRING  

atmConfVpCCDirection 1.3.6.1.4.1.164.12.3.2.1.3.1.6
both(2) - Agent send OAM CC cells and check received OAM CC cells source(4)- Agent send OAM CC cells. sink(5) - Agent checks received OAM CC cells.
OBJECT-TYPE    
  INTEGER both(2), source(4), sink(5)  

atmConfVpCreationTime 1.3.6.1.4.1.164.12.3.2.1.3.1.7
A date-time in which the VP was created.
OBJECT-TYPE    
  DateAndTime  

atmConfVpOamSupport 1.3.6.1.4.1.164.12.3.2.1.3.1.8
OAM support mode, which determines the device location in a segment wise.
OBJECT-TYPE    
  INTEGER intermediate(1), segmentTermination(2), endToEndTermination(3)  

atmConfVpCCOperStatus 1.3.6.1.4.1.164.12.3.2.1.3.1.9
initial(1) - The CC activation process is not started. source(4) - Agent sends OAM CC cells. sink(5) - Agent checks received OAM CC cells. both (8) - OAM CC of local and remote agents activation. timeout (9) - Timeout occured on receiving answer from the remote agent. denied (10) - CC activation process rejected by remote agent. conflict (11) - local and remote sides requested activation simultaneously. manual (12) - OAM CC of local agent activated manually.
OBJECT-TYPE    
  INTEGER initial(1), source(4), sink(5), both(8), timeout(9), denied(10), conflict(11), manual(12)  

atmConfVpLoopbackTraffic 1.3.6.1.4.1.164.12.3.2.1.3.1.10
This parameter has both command and status meanings: off(2) - Set to 'Off' will Stop traffic loop. Getting this value means that the loop is not running. on (3) - Set to 'On' will start traffic loop. Getting this value means that the loop is currently running.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmConfVpLoopbackFailureInd 1.3.6.1.4.1.164.12.3.2.1.3.1.11
This object allows user to define the Indication that will be created upon a LB cell failure. disabled(2) - no indication will be created. segmentAis(3) - will cause Tx of a segment AIS. segmentRdi(4) - will cause Tx of a segment RDI. segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. endToEndAis(6) - will cause Tx of an End to End AIS. endToEndRdi(7) - will cause Tx of an End to End RDI. endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI. Default: disabled(2).
OBJECT-TYPE    
  INTEGER disabled(2), segmentAis(3), segmentRdi(4), segmentAisAndRdi(5), endToEndAis(6), endToEndRdi(7), endToEndAisAndRdi(8)  

atmConfVpLoopbackFailureThreshold 1.3.6.1.4.1.164.12.3.2.1.3.1.12
The number of the LB failures before starting transmission of the Indication defined by atmConfVcLoopbackFailureInd. Range: 1..16. Default: 1.
OBJECT-TYPE    
  Integer32  

atmConfVpOamDirection 1.3.6.1.4.1.164.12.3.2.1.3.1.13
The direction of OAM cell insertion. downStream(2) - The OAM cell will be inserted in downStream. upStream(3) - The OAM cell will be inserted in upStream.
OBJECT-TYPE    
  INTEGER notApplicable(1), downStream(2), upStream(3)  

atmNteAlarmVpTable 1.3.6.1.4.1.164.12.3.2.1.5
The ATM VP Alarm table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteAlarmVpEntry

atmNteAlarmVpEntry 1.3.6.1.4.1.164.12.3.2.1.5.1
An entry in the ATM VP Alarm table. ifIndex of the ATM layer.
OBJECT-TYPE    
  AtmNteAlarmVpEntry  

atmNteVpAlarmVpi 1.3.6.1.4.1.164.12.3.2.1.5.1.1
The VPI on which there is an active alarm.
OBJECT-TYPE    
  Integer32  

atmNteVpActiveAlarms 1.3.6.1.4.1.164.12.3.2.1.5.1.2
A Bit String of the active alarms on this VP. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - VP AIS 2 - VP Loss Of Continuity 3 - VP RDI Reception 4 - VP Errored Cells > Threshold 5 - VP Lost Cells > Threshold 6 - VP Misinserted Cells > Threshold
OBJECT-TYPE    
  Integer32  

atmNteAlarmVcTable 1.3.6.1.4.1.164.12.3.2.1.6
The ATM VC Alarm table.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteAlarmVcEntry

atmNteAlarmVcEntry 1.3.6.1.4.1.164.12.3.2.1.6.1
An entry in the ATM VC Alarm table. ifIndex of the ATM layer.
OBJECT-TYPE    
  AtmNteAlarmVcEntry  

atmNteVcAlarmVpi 1.3.6.1.4.1.164.12.3.2.1.6.1.1
The VPI of the VC on which there is an active alarm.
OBJECT-TYPE    
  Integer32  

atmNteVcAlarmVci 1.3.6.1.4.1.164.12.3.2.1.6.1.2
The VCI of the VC on which there is an active alarm.
OBJECT-TYPE    
  Integer32  

atmNteVcActiveAlarms 1.3.6.1.4.1.164.12.3.2.1.6.1.3
A Bit String of the active alarms on this VC. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - VC AIS 2 - VC Loss Of Continuity 3 - VC RDI 4 - VC Errored Cells > Threshold 5 - VC Lost Cells > Threshold 6 - VC Misinserted Cells > Threshold 7 - Tx VC AIS 8 - Tx VC RDI
OBJECT-TYPE    
  Integer32  

radExperimental 1.3.6.1.4.1.164.20
OBJECT IDENTIFIER    

Defined Objects

MacAddress  
OCTET STRING SIZE(6)    

TimeSlots  
OCTET STRING SIZE(4)    

MngEntry  
SEQUENCE    
  Integer32 as mngID  
  IpAddress as mngIP  
  IpAddress as mngIPMask  
  Integer32 as mngTrapMask  

TrapEntry  
SEQUENCE    
  Integer32 as trapID  
  DisplayString as trapVal  
  TimeTicks as trapTimeSinceOccurrence  

IntSwdlEntry  
SEQUENCE    
  Integer32 as intSwdlObjIdx  
  Integer32 as intSwdlFileIdx  
  DisplayString as intSwdlFileName  
  DisplayString as intSwdlFileSwVer  
  DisplayString as intSwdlSwDate  
  DisplayString as intSwdlSize  
  INTEGER as intSwdlCmd  
  OCTET STRING as intSwdlToSubSystem  

SwdlStatusEntry  
SEQUENCE    
  Integer32 as swdlStatusTypeIdx  
  Integer32 as swdlStatusIdx  
  DisplayString as swdlStatusFileName  
  DisplayString as swdlStatusSlot  
  DisplayString as swdlStatusSubSystem  
  Integer32 as swdlStatusStatus  
  DisplayString as swdlStatusTime  

PhysicalConnectorEntry  
SEQUENCE    
  Integer32 as portIdx  
  INTEGER as physicalConnector  
  INTEGER as portOptWaveLength  
  INTEGER as portOptMode  

PrtSpEntry  
SEQUENCE    
  Integer32 as prtSupervisoryIndex  
  INTEGER as prtSupervisoryRate  
  INTEGER as prtSupervisoryDataBits  
  INTEGER as prtSupervisoryParity  
  INTEGER as prtSupervisoryStopBits  
  INTEGER as prtSupervisoryUsage  
  INTEGER as prtSupervisoryInterface  
  INTEGER as prtSupervisoryCTS  
  INTEGER as prtSupervisoryDcdDelay  
  INTEGER as prtSupervisoryDSR  
  INTEGER as prtSupervisoryRoutProtocol  

PrtPerfEntry  
SEQUENCE    
  Integer32 as prtPerfIdx  
  INTEGER as prtPerfPeriodRef  
  Integer32 as prtPerfElapsedTime  
  Integer32 as prtPerfUAS  
  Integer32 as prtPerfES  
  Integer32 as prtPerfSES  
  Integer32 as prtPerfBBE  
  Integer32 as prtPerfBlocksPerSec  
  TimeTicks as prtPerfTimeTag  
  INTEGER as prtPerfSaveAndResetCmd  

PrtTestEntry  
SEQUENCE    
  Integer32 as prtTestIdx  
  Integer32 as prtTestCmdAndStatus  
  Integer32 as prtBertCounter  
  INTEGER as prtTestInitiator  
  Integer32 as prtTestTimeout  

PrtParamEntry  
SEQUENCE    
  Integer32 as prtParamIdx  
  Integer32 as prtControlCnfg  
  INTEGER as prtParamClkSrc  
  INTEGER as prtParamPhantom  
  INTEGER as prtParamResetStatsCmd  
  TimeStamp as prtParamLastResetStatsTime  

PrtIpParamEntry  
SEQUENCE    
  Integer32 as prtIpParamConfigIdx  
  Integer32 as prtIpParamSlotIdx  
  Integer32 as prtIpParamIdx  
  IpAddress as prtIpParamHostIP  
  IpAddress as prtIpParamHostMask  
  IpAddress as prtIpParamDefaultGateway  
  INTEGER as prtIpParamMediaMode  
  INTEGER as prtIpParamMediaRate  
  INTEGER as prtIpParamMngVlanSupport  
  Integer32 as prtIpParamMngVlanId  
  Integer32 as prtIpParamMngVlanPriority  
  INTEGER as prtIpParamRingMode  

SystemPsEntry  
SEQUENCE    
  Integer32 as systemPsIndex1  
  Integer32 as systemPsIndex2  
  INTEGER as systemPsType  
  INTEGER as systemPsStatus  
  INTEGER as systemPsHotSwap  

XcEntry  
SEQUENCE    
  Integer32 as xcIndex  
  Integer32 as xcIfIndex1  
  Integer32 as xcVpi  
  Integer32 as xcVci  
  Integer32 as xcIfIndex2  
  RowStatus as xcRowStatus  
  DisplayString as xcDescr  
  INTEGER as xcAdminStatus  
  INTEGER as xcOperStatus  

ModlParamEntry  
SEQUENCE    
  Integer32 as modlParamIndex  
  INTEGER as modlParamReset  
  INTEGER as modlParamSwdlStatus  
  OCTET STRING as modlParamLeds  

SegTREntry  
SEQUENCE    
  Integer32 as segTRID  
  Integer32 as segTRLastSlot  
  Integer32 as segTRFirstSlot  
  INTEGER as segTRStatus  

MdlTREntry  
SEQUENCE    
  Integer32 as mdlTRID  
  Integer32 as mdlTRSegID  
  INTEGER as mdlTRType  
  DisplayString as mdlTRHwVer  
  DisplayString as mdlTRSwVer  
  Integer32 as mdlTRTotalNoOfPrt  
  OBJECT IDENTIFIER as mdlTRSpecific  

PrtTREntry  
SEQUENCE    
  Integer32 as prtTRModuleID  
  Integer32 as prtTRID  
  INTEGER as prtTRFunctionality  
  INTEGER as prtTRConnectorType  
  INTEGER as prtTRAdminCmd  
  INTEGER as prtTRActiveState  
  INTEGER as prtTRTrapMaskEnable  
  INTEGER as prtTRstatus  
  INTEGER as prtTRCableProtectEnable  
  INTEGER as prtTRCableState  
  MacAddress as prtTRMACAddress  
  OBJECT IDENTIFIER as prtTRSpecific  

PrtTRMacAddressEntry  
SEQUENCE    
  Integer32 as prtTRMacAddressModuleID  
  Integer32 as prtTRMacAddressPortID  
  Integer32 as prtTRMacAddressID  
  MacAddress as prtTRMACAddressValue  

SegRRSecEntry  
SEQUENCE    
  Integer32 as segRRID  
  Integer32 as segRRSecID  
  INTEGER as segRRSecEnable  
  MacAddress as segRRSecurityPattern  
  MacAddress as segRRSecurityMask  

MdlRREntry  
SEQUENCE    
  Integer32 as mdlRRid  
  INTEGER as mdlRRTLRstatus  
  INTEGER as mdlRRtermination  
  INTEGER as mdlRRReset  
  OCTET STRING as mdlRRLed  
  INTEGER as mdlRRSpeed  
  INTEGER as mdlRRMngAutoDis  
  INTEGER as mdlRRAutodisable  
  OCTET STRING as mdlRRConfigMsg  
  INTEGER as mdlRRMngState  
  INTEGER as mdlRRType  
  DisplayString as mdlRRHwVer  
  DisplayString as mdlRRSwVer  
  OBJECT IDENTIFIER as mdlRRSpecific  

MdlIBEntry  
SEQUENCE    
  Integer32 as mdlIBid  
  Integer32 as mdlIBsegID  
  INTEGER as mdlIBCorrelationEnable  
  INTEGER as mdlIBAutorecEnable  
  INTEGER as mdlIBAutorecResult  
  INTEGER as mdlIBcommand  
  INTEGER as mdlIBstate  
  INTEGER as mdlIBagnt  
  IpAddress as mdlIBIpAddress  
  MacAddress as mdlIBLocalMacAddr  
  MacAddress as mdlIBbrnInMacAddr  
  INTEGER as mdlIBLocalAddrStatus  
  INTEGER as mdlIBTrapMaskEnable  

MdlBRGEntry  
SEQUENCE    
  Integer32 as mdlBRGid  
  INTEGER as mdlBRGReady  
  DisplayString as mdlBRGStatus  
  INTEGER as mdlBRGLocation  
  IpAddress as mdlBRGIpAddress  
  MacAddress as mdlBRGMacAddr  
  INTEGER as mdlBRGAdapterState  
  INTEGER as mdlBRGBypassSw  

MdlMMEntry  
SEQUENCE    
  Integer32 as mdlMMid  
  INTEGER as mdlMMBertCmd  

MdlETEntry  
SEQUENCE    
  Integer32 as mdlETid  
  INTEGER as mdlETSAmode  

PrtRREntry  
SEQUENCE    
  Integer32 as prtRRmdlID  
  Integer32 as prtRRID  
  INTEGER as prtRRSecurityState  
  INTEGER as prtRRSecurityEnable  
  MacAddress as prtRRSecurityMask  
  MacAddress as prtRRSecurityPattern  
  INTEGER as prtRRJitterAttenEnable  
  OCTET STRING as prtRRConfigMsg  
  INTEGER as prtRRFlipAutoDisable  
  MacAddress as prtRRSecurityMask2  
  MacAddress as prtRRSecurityPattern2  
  INTEGER as prtRRMode  
  INTEGER as prtRRAttachment  

PrtMMEntry  
SEQUENCE    
  Integer32 as prtMMmdlID  
  Integer32 as prtMMID  
  INTEGER as prtMMAdminCmd  
  INTEGER as prtMMOperStatus  
  INTEGER as prtMMTestStatus  
  INTEGER as prtMMBertResult  
  INTEGER as prtMMTrapMaskEnable  

PrtETEntry  
SEQUENCE    
  Integer32 as prtETmdlID  
  Integer32 as prtETID  
  INTEGER as prtETTrapMaskEnable  

PrtRRSecEntry  
SEQUENCE    
  Integer32 as prtRRSecmdlID  
  Integer32 as prtRRSecPrtID  
  Integer32 as prtRRSecID  
  MacAddress as prtRRSecMask  
  MacAddress as prtRRSecPattern  

RadFddiStationEntry  
SEQUENCE    
  Integer32 as radFddiStationIndex  
  INTEGER as radFddiStationType  
  INTEGER as radFddiStationBus1TestResult  
  INTEGER as radFddiStationBus2TestResult  
  INTEGER as radFddiStationTempDeInsertAction  
  INTEGER as radFddiStationPerformTest  
  INTEGER as radFddiStationOpticalSwitchStatus  

RadFddiSMTEntry  
SEQUENCE    
  Integer32 as radFddiSMTIndex  
  Integer32 as radFddiSMTStation  
  INTEGER as radFddiSMTCFState  
  Integer32 as radFddiSMTLeftSlot  
  Integer32 as radFddiSMTRightSlot  

RadFddiMACEntry  
SEQUENCE    
  Integer32 as radFddiMACSMTIndex  
  Integer32 as radFddiMACIndex  
  Integer32 as radFddiMACStation  
  Integer32 as radFddiMACTestResult  
  Counter32 as radFddiMACTokenCt  
  Integer32 as radFddiMACRingLoad  
  OCTET STRING as radFddiMACRingLoadBuffer  
  Integer32 as radFddiMACRingLoadTrsh  
  Integer32 as radFddiMACRingLoadPeak  
  OCTET STRING as radFddiMACDownstreamNbr  
  INTEGER as radFddiMACRingStatus  
  Integer32 as radFddiMACRingUtilization  
  Integer32 as radFddiMACRingPeakUtilization  

RadFddiGroupEntry  
SEQUENCE    
  Integer32 as radFddiGroupId  
  INTEGER as radFddiGroupRedundancy  
  INTEGER as radFddiGroupTopologyMode  
  INTEGER as radFddiGroupTestResult  
  INTEGER as radFddiGroupConfigStatus  
  INTEGER as radFddiGroupAutoRightLoop  
  INTEGER as radFddiGroupAutoLeftLoop  
  INTEGER as radFddiGroupManRightLoop  
  INTEGER as radFddiGroupManLeftLoop  
  INTEGER as radFddiGroupOpticalSwitchStatus  

RadFddiPortEntry  
SEQUENCE    
  Integer32 as radFddiPortGroupID  
  Integer32 as radFddiPortID  
  INTEGER as radFddiPortTestResult  
  Integer32 as radFddiPortNumberOfConnectedStations  
  OCTET STRING as radFddiPortConnectedStations  
  INTEGER as radFddiPortCurrentPath  
  INTEGER as radFddiPortFunctionalStatus  

RadBridgeMaskEntry  
SEQUENCE    
  INTEGER as radBridgeMaskType  
  Integer32 as radBridgeMaskIfIndex  
  Integer32 as radBridgeMaskNum  
  INTEGER as radBridgeMaskDest  
  OCTET STRING as radBridgeMaskPat1  
  OCTET STRING as radBridgeMaskActiveBit1  
  INTEGER as radBridgeMaskFrom1  
  Integer32 as radBridgeMaskOffset1  
  INTEGER as radBridgeMaskCond1  
  OCTET STRING as radBridgeMaskPat2  
  OCTET STRING as radBridgeMaskActiveBit2  
  INTEGER as radBridgeMaskFrom2  
  Integer32 as radBridgeMaskOffset2  
  INTEGER as radBridgeMaskCond2  
  OCTET STRING as radBridgeMaskPat3  
  OCTET STRING as radBridgeMaskActiveBit3  
  INTEGER as radBridgeMaskFrom3  
  Integer32 as radBridgeMaskOffset3  
  INTEGER as radBridgeMaskCond3  
  INTEGER as radBridgeMaskOper  

RadBridgeCODEntry  
SEQUENCE    
  Integer32 as radBridgeCODIfIndex  
  INTEGER as radBridgeCODManualConnect  
  INTEGER as radBridgeCODMode  
  Integer32 as radBridgeCODConnectDelay  
  Integer32 as radBridgeCODisConnectDelay  
  INTEGER as radBridgeCODImplicitSwitch  
  Counter32 as radBridgeCODNumAccess  
  Integer32 as radBridgeCODTotalConnecTime  

RadBridgeCODTimeTriggerEntry  
SEQUENCE    
  Integer32 as radBridgeCODTimeIfIndex  
  INTEGER as radBridgeCODDay  
  Integer32 as radBridgeCODTimeTriggerNum  
  DisplayString as radBridgeCODTimeTriggerFrom  
  DisplayString as radBridgeCODTimeTriggerTo  
  INTEGER as radBridgeCODTimeTriggerStatus  

RadBridgeCODTrafficEntry  
SEQUENCE    
  INTEGER as radBridgeCODProtocolType  
  INTEGER as radBridgeCODTrafficTriggerStatus  

RadBridgeCODCondEntry  
SEQUENCE    
  Integer32 as radBridgeCODCondIfIndex  
  INTEGER as radBridgeCODOriginateConnectCondition  
  INTEGER as radBridgeCODOriginateDisConnectCondition  
  Integer32 as radBridgeCODOriginateDisConnectDelay  
  INTEGER as radBridgeCODAnswerConnectCondition  
  OBJECT IDENTIFIER as radBridgeCODSpecificOnTrafficOIDCondition  
  Integer32 as radBridgeCODDisConnectMinimunFramesNumber  

RadBridgeIPXRipTableEntry  
SEQUENCE    
  OCTET STRING as radBridgeIPXRipDestNetwork SIZE(4)  
  INTEGER as radBridgeIPXRipPolicy  
  OCTET STRING as radBridgeIPXRipForwardingRouter SIZE(6)  
  Integer32 as radBridgeIPXRipNIC  
  Integer32 as radBridgeIPXRipTickMetric  
  Integer32 as radBridgeIPXRipHopMetric  
  TimeTicks as radBridgeIPXRipAgingTime  
  INTEGER as radBridgeIPXRipValueStatus  
  INTEGER as radBridgeIPXRipForwardType  

RadBridgeIPXRipInfEntry  
SEQUENCE    
  Integer32 as radBridgeIPXRipInfIfIndex  
  Integer32 as radBridgeIPXRipInfBcastUpdate  
  Integer32 as radBridgeIPXRipInfAgeMultiplier  

RadBridgeIPXSapTableEntry  
SEQUENCE    
  Integer32 as radBridgeIPXSapServerType  
  DisplayString as radBridgeIPXSapName SIZE(48)  
  OCTET STRING as radBridgeIPXSapNetwork SIZE(4)  
  OCTET STRING as radBridgeIPXSapNode SIZE(6)  
  Integer32 as radBridgeIPXSapSocket  
  Integer32 as radBridgeIPXSapHopsToServer  
  Integer32 as radBridgeIPXSapNIC  
  TimeTicks as radBridgeIPXSapAgingTime  
  INTEGER as radBridgeIPXSapStatus  

RadBridgeIPXSapInfEntry  
SEQUENCE    
  Integer32 as radBridgeIPXSapInfIfIndex  
  Integer32 as radBridgeIPXSapInfBcastUpdate  
  Integer32 as radBridgeIPXSapInfAgeMultiplier  

GenAddress  
OCTET STRING SIZE(12)    

MaskingEntry  
SEQUENCE    
  INTEGER as maskingType  
  Integer32 as maskingIfIndex  
  Integer32 as maskingIndex  
  INTEGER as maskingProtocolType  
  OBJECT IDENTIFIER as maskingSmartMaskOID  
  INTEGER as maskingFrameType  
  INTEGER as maskingFrameTypeCondition  
  GenAddress as maskingSourceAddress  
  GenAddress as maskingSourceActiveBits  
  INTEGER as maskingSourceMacOrNet  
  INTEGER as maskingSourceCondition  
  GenAddress as maskingDestAddress  
  GenAddress as maskingDestActiveBits  
  INTEGER as maskingDestMacOrNet  
  INTEGER as maskingDestCondition  
  INTEGER as maskingLowLevelProt  
  INTEGER as maskingLowLevelProtCondition  
  Integer32 as maskingHighLevelProt  
  INTEGER as maskingHighLevelProtCondition  
  Integer32 as maskingPortNum  
  INTEGER as maskingPortNumCondition  
  INTEGER as maskingOperation  
  Integer32 as maskingSrcPortNum  
  INTEGER as maskingSrcPortNumCondition  

RadBridgeCurrentEntry  
SEQUENCE    
  Integer32 as radBridgeCurrentIndex  
  Gauge32 as radBridgeCurrentIngressFilteringDiscardedFrames  
  Gauge32 as radBridgeCurrentFrameTypeDiscardedFrames  

RadBridgeIntervalEntry  
SEQUENCE    
  Integer32 as radBridgeIntervalIndex  
  Integer32 as radBridgeIntervalNumber  
  Gauge32 as radBridgeIntervalIngressFilteringDiscardedFrames  
  Gauge32 as radBridgeIntervalFrameTypeDiscardedFrames  

TrimIfEntry  
SEQUENCE    
  Integer32 as trimIfIndex  
  Integer32 as trimIfBoardNum  
  IpAddress as trimIfNetAddress  
  INTEGER as trimIfStatus  
  INTEGER as trimIfClockType  
  Integer32 as trimIfBaudRate  
  Integer32 as trimIfCost  
  INTEGER as trimIfCompression  
  INTEGER as trimIfCompressionStatus  
  Integer32 as trimIfCompressionRate  
  INTEGER as trimIfLATCompression  
  INTEGER as trimIfCompressionType  
  INTEGER as trimIfFilterMode  
  INTEGER as trimIfConType  
  DisplayString as trimIfRemAddress  
  DisplayString as trimIfLocSubAddress  
  DisplayString as trimIfRemSubAddress  
  INTEGER as trimIfCLIVerification  

TrimIfThresholdRepEntry  
SEQUENCE    
  Integer32 as trimIfThreRepId  
  INTEGER as trimIfThreRepCounterId  
  Integer32 as trimThresholdValue  
  Integer32 as trimIfThreRepSampleRate  
  Integer32 as trimIfThreRepTrapRate  

TrimBackUpEntry  
SEQUENCE    
  Integer32 as trimBackUpDay  
  DisplayString as trimBackUpFromTo  

TrimTRIfEntry  
SEQUENCE    
  Integer32 as trimTRIfIndex  
  INTEGER as trimTREarlyTokenRelease  
  MacAddress as trimTRLocalAdminAddress  
  INTEGER as trimTRLocalAdminAddressStatus  

LanrangerBootPEntry  
SEQUENCE    
  IpAddress as lanrangerBootPIpAddress  
  INTEGER as lanrangerBootPIfIndex  
  INTEGER as lanrangerBootPOperation  

LanrangerLinkEntry  
SEQUENCE    
  Integer32 as lanrangerLinkIndex  
  INTEGER as lanrangerLinkType  
  INTEGER as lanrangerLinkState  
  INTEGER as lanrangerLinkDTRMode  
  INTEGER as lanrangerLinkStatus  
  INTEGER as lanrangerLinkConnectionStatus  
  Integer32 as lanrangerLinkNumOfLogLinks  
  INTEGER as lanrangerLinkReset  
  Counter32 as lanrangerLinkRxMaskedFrames  
  INTEGER as lanrangerLinkLayer2Type  
  INTEGER as lanrangerLinkLayer3Type  
  Integer32 as lanrangerBackupLink  
  Integer32 as wrWanThrottle  

LanrangerLinkConnEntry  
SEQUENCE    
  Integer32 as lanrangerLinkConnPhysLink  
  Integer32 as lanrangerLinkConnAid  
  MacAddress as lanrangerLinkConnMacAddr  
  INTEGER as lanrangerLinkConnStatus  
  INTEGER as lanrangerLinkConnDeviceType  
  DisplayString as lanrangerLinkConnDeviceName  
  DisplayString as lanrangerLinkConnDeviceSWVer  
  Integer32 as lanrangerLinkConnNumLanStation  
  INTEGER as lanrangerLinkSyncStatus  

LanrangerModemEntry  
SEQUENCE    
  Integer32 as lanrangerModemLinkIndex  
  DisplayString as lanrangerModemName  
  DisplayString as lanrangerModemSettingString  
  INTEGER as lanrangerModemAutobaudingSpeed  
  INTEGER as lanrangerModemResetBeforeSetup  
  INTEGER as lanrangerModemAnalyzeAnswers  
  INTEGER as lanrangerModemSpeaker  
  DisplayString as lanrangerModemDialingNumber  
  Integer32 as lanrangerModemDialRetries  
  DisplayString as wrLocalDialBackNumber  
  Integer32 as wrRingsBeforeAnswer  

LanrangerLinkPktSwEntry  
SEQUENCE    
  Integer32 as lanrangerLinkPktSwIndex  
  INTEGER as lanrangerLinkPktSwType  
  INTEGER as lanrangerLinkPktSwControlSignal  
  Integer32 as lanrangerLinkPktSwSpeed  
  INTEGER as lanrangerLinkPktSwConfigParity  
  INTEGER as lanrangerLinkPktSwConfigStopBit  
  INTEGER as lanrangerLinkPktSwResetModule  

LanrangerStationEntry  
SEQUENCE    
  Integer32 as lanrangerStationPhysLink  
  Integer32 as lanrangerStationLogLink  
  MacAddress as lanrangerStationAddress  
  INTEGER as lanrangerStationStatus  
  INTEGER as lanrangerStationSpoofingStatus  

LanrangerPermanentEntry  
SEQUENCE    
  Integer32 as lanrangerPermanentIfIndex  
  Integer32 as lanrangerPermanentLogLink  
  MacAddress as lanrangerPermanentAddress  
  INTEGER as lanrangerPermanentOperation  

LanrangerSpoofingEntry  
SEQUENCE    
  Integer32 as lanrangerSpoofingGroup  
  MacAddress as lanrangerSpoofingMacAddress  
  Integer32 as lanrangerSpoofingAging  
  Integer32 as lanrangerSpoofingTimeLeft  

WrPPPEntry  
SEQUENCE    
  INTEGER as wrPPPCompressionHeaderField  
  INTEGER as wrPPPCompressionProtocolFields  
  INTEGER as wrPPPSTACCompressionType  
  INTEGER as wrPPPAuthProtocol  
  INTEGER as wrPPPSecurityType  
  SnmpAdminString as wrPPPUserName  
  SnmpAdminString as wrPPPPassword  
  Integer32 as wrPPPLinkActiveTime  

FebFtbTranslIfEntry  
SEQUENCE    
  Integer32 as febFtbTranslIfIndex  
  OCTET STRING as febFtbTunnelProtocol  
  INTEGER as febFtbTranslIPXRawEthernet  

FebFtbLanTabEntry  
SEQUENCE    
  Integer32 as febFtbLanTabIfIndex  
  Integer32 as febFtbLanTabEntNumber  

MlbAddressEntry  
SEQUENCE    
  Integer32 as mlbPortIndex  
  MacAddress as mlbBurnAddress  
  MacAddress as mlbLocAddress  
  INTEGER as mlbActiveAddress  

Sap  
OCTET STRING SIZE(1)    

SdlcAddr  
OCTET STRING SIZE(1)    

NvaAgentEntry  
SEQUENCE    
  Integer32 as nvaAgIndex  
  INTEGER as nvaAgAdminStatus  
  INTEGER as nvaAgOperState  
  OCTET STRING as nvaAgFilter  
  INTEGER as nvaAgAllowRunCmd  
  INTEGER as nvaAgAccessType  
  Integer32 as nvaAgIfIndex  
  OCTET STRING as nvaAgXidBlockId  
  OCTET STRING as nvaAgXidBlockNum  
  Sap as nvaAgSSap  
  Sap as nvaAgDSap  
  MacAddress as nvaAgRemMacAddr  
  SdlcAddr as nvaAgSdlcAddr  
  DisplayString as nvaAgResourceName  

NvaAgentStatEntry  
SEQUENCE    
  Integer32 as nvaAgStatIndex  
  TimeTicks as nvaAgStatTime  
  Counter32 as nvaAgActPu  
  Counter32 as nvaAgDactPu  
  Counter32 as nvaAgRpNmvt  
  Counter32 as nvaAgRnNmvt  
  Counter32 as nvaAgSpNmvt  
  Counter32 as nvaAgSAlerts  
  Counter32 as nvaAgRRunCmd  
  Counter32 as nvaAgSRunCmd  
  Counter32 as nvaAgSPdstat  

SnaSessEntry  
SEQUENCE    
  Integer32 as sessIfIndex  
  Integer32 as sessId  
  INTEGER as sessSide  
  Integer32 as sessDev  
  INTEGER as sessAdminStatus  
  INTEGER as sessOperState  
  INTEGER as sessAccessType  
  OCTET STRING as sessSXidBlockId  
  OCTET STRING as sessSXidBlockNum  
  Sap as sessSSap  
  Sap as sessDSap  
  MacAddress as sessRemMacAddr  
  SdlcAddr as sessSdlcAddr  
  SdlcAddr as sessGroupPoll  
  INTEGER as sessRole  
  INTEGER as sessIpEncapsulated  
  IpAddress as sessDestIpAddr  
  OCTET STRING as sessRemX25Addr  

SnaSessTuneEntry  
SEQUENCE    
  Integer32 as sessTuneIfIndex  
  Integer32 as sessTuneId  
  INTEGER as sessTuneSide  
  Integer32 as sessBufferSize  
  INTEGER as sessSegmentation  
  INTEGER as sessFirstSide  
  Integer32 as sessWindow  
  INTEGER as sessDuplex  
  OCTET STRING as sessRXidBlockId  
  OCTET STRING as sessRXidBlockNum  
  INTEGER as sessCheckXid  
  Integer32 as sessT1  
  Integer32 as sessTi  
  Integer32 as sessT2  
  Integer32 as sessN2  
  Integer32 as sessUdpPort  

SnaSessStatEntry  
SEQUENCE    
  Integer32 as sessStatIfIndex  
  Integer32 as sessStatId  
  INTEGER as sessStatSide  
  TimeTicks as sessStatTime  
  Counter32 as sessSPius  
  Counter32 as sessSBytes  
  Counter32 as sessRPius  
  Counter32 as sessRBytes  
  Counter32 as sessSessFailure  
  Counter32 as sessXidDenieds  

SnaSessQllcEntry  
SEQUENCE    
  Integer32 as sessQllcIfIndex  
  Integer32 as sessQllcId  
  INTEGER as sessQllcSide  
  INTEGER as sessInCalls  
  INTEGER as sessOutCalls  
  INTEGER as sessPVC  
  OCTET STRING as sessCallReqData  
  OCTET STRING as sessConnReqFacility  
  OCTET STRING as sessGroupId  
  OCTET STRING as sessDtePswd  
  OCTET STRING as sessDteId  
  Integer32 as sessMaxInPktSize  
  Integer32 as sessMaxOutPktSize  
  OCTET STRING as sessCallIndReverse  

SdlcEntry  
SEQUENCE    
  Integer32 as sdlcIfIndex  
  INTEGER as sdlcNrz  
  INTEGER as sdlcDuplex  
  INTEGER as sdlcClockType  
  Integer32 as sdlcSpeed  
  DisplayString as sdlcConnectorType  
  INTEGER as sdlcRts  

SdlcStatEntry  
SEQUENCE    
  Integer32 as sdlcStatIfIndex  
  TimeTicks as sdlcTimeSinceReset  
  Counter32 as sdlcStatFramesTrans  
  Counter32 as sdlcStatBytesTrans  
  Counter32 as sdlcStatFramesRcv  
  Counter32 as sdlcStatBytesRcv  
  Counter32 as sdlcStatFramesAbort  
  Counter32 as sdlcStatFramesBad  
  Counter32 as sdlcStatFramesCrc  

CvtDot5Entry  
SEQUENCE    
  Integer32 as cvtDot5IfIndex  
  MacAddress as cvtDot5MacAddr  
  INTEGER as cvtDot5Commands  
  INTEGER as cvtDot5RingSpeed  
  INTEGER as cvtDot5ActMonParticipate  
  MacAddress as cvtDot5Functional  

CvtDot3Entry  
SEQUENCE    
  Integer32 as cvtDot3IfIndex  
  MacAddress as cvtDot3MacAddr  
  INTEGER as cvtDot3Commands  
  INTEGER as cvtDot3ActMonParticipate  
  MacAddress as cvtDot3Functional  

StkHubSecurityEntry  
SEQUENCE    
  Integer32 as stkHubSecID  
  INTEGER as stkHubSecEnable  
  OCTET STRING as stkHubSecurityPattern  
  OCTET STRING as stkHubSecurityMask  

StkHubPrtSecurityEntry  
SEQUENCE    
  Integer32 as stkHubModuleID  
  Integer32 as stkHubPrtID  
  Integer32 as stkHubPrtSecID  
  INTEGER as stkHubPrtSecurityEnable  
  OCTET STRING as stkHubPrtSecurityPattern  
  OCTET STRING as stkHubPrtSecurityMask  

StkHubTRMdlEntry  
SEQUENCE    
  Integer32 as stkHubTRMdlID  
  INTEGER as stkHubTRMdlType  
  INTEGER as stkHubTRMdlReset  
  OCTET STRING as stkHubTRMdlLed  
  INTEGER as stkHubTRMdlSpeed  
  INTEGER as stkHubTRMdlMngState  
  INTEGER as stkHubTRMdlAutodisable  
  OCTET STRING as stkHubTRMdlConfigMsg  

StkHubTRPrtEntry  
SEQUENCE    
  Integer32 as stkHubTRPrtMdlID  
  Integer32 as stkHubTRPrtID  
  INTEGER as stkHubTRPrtFunctionality  
  INTEGER as stkHubTRPrtConnectorType  
  INTEGER as stkHubTRPrtAdminCmd  
  INTEGER as stkHubTRPrtActiveState  
  INTEGER as stkHubTRPrtTrapMaskEnable  
  INTEGER as stkHubTRPrtStatus  
  INTEGER as stkHubTRPrtCableProtectEnable  
  INTEGER as stkHubTRPrtFlipProtectEnable  
  MacAddress as stkHubTRPrtMACAddress  
  INTEGER as stkHubTRPrtType  

StkHubETMdlEntry  
SEQUENCE    
  Integer32 as stkHubETMdlID  
  OCTET STRING as stkHubETMdlLed  
  INTEGER as stkHubETMdlReset  

EtRptrEntry  
SEQUENCE    
  Integer32 as etRptrIndex  
  Integer32 as etRptrGroupCapacity  
  INTEGER as etRptrOperStatus  
  DisplayString as etRptrHealthText  
  INTEGER as etRptrReset  
  INTEGER as etRptrNonDisruptTest  
  Gauge32 as etRptrTotalPartitionedPorts  
  Integer32 as etRptrMdlVector  
  Counter32 as etRptrMonitorTransmitCollisions  

EtRptrSecEntry  
SEQUENCE    
  Integer32 as etRptrId  
  Integer32 as etRptrSecID  
  INTEGER as etRptrSecEnable  
  OCTET STRING as etRptrSecPattern  
  OCTET STRING as etRptrSecMask  

AgnSAlrEntry  
SEQUENCE    
  Integer32 as agnSAlrIdx  
  DisplayString as agnSAlrCodeDescription SIZE(0..255)  
  Integer32 as agnSAlrCode  
  INTEGER as agnSAlrSeverity  
  INTEGER as agnSAlrState  
  Integer32 as agnSAlrCounter  
  INTEGER as agnSAlrMask  
  INTEGER as agnSAlrInvert  

AgnSErrListEntry  
SEQUENCE    
  Integer32 as agnSErrIdx  
  DisplayString as agnSErrDescription SIZE(0..255)  

AgnSCnfgEntry  
SEQUENCE    
  Integer32 as agnSEntryIdx  
  INTEGER as agnSEntryIsValid  

AgnCClkSrcEntry  
SEQUENCE    
  Integer32 as agnCClkCnfgIdx  
  Integer32 as agnCClkSrcIdx  
  INTEGER as agnCClkSrcMode  
  INTEGER as agnCClkSrcSlt  
  Integer32 as agnCClkSrcPrt  

AgnCnfgDataEntry  
SEQUENCE    
  Integer32 as agnCnfgIdx  
  DisplayString as agnCnfgDesc  
  DisplayString as agnCnfgUpdDate  
  DisplayString as agnCnfgUpdTime  
  IpAddress as agnCnfgUpdMnger  

AgnCnfgAlrEntry  
SEQUENCE    
  Integer32 as agnCnfgAlrCode  
  INTEGER as agnCnfgAlrSlot  
  Integer32 as agnCnfgAlrPort  
  INTEGER as agnCnfgAlrMask  
  INTEGER as agnCnfgAlrInvert  
  INTEGER as agnCnfgAlrFilter  
  Integer32 as agnCnfgAlrFilterSet  
  Integer32 as agnCnfgAlrFilterReset  

AgnCnfgAlrReportEntry  
SEQUENCE    
  INTEGER as agnCnfgAlrReportType  
  INTEGER as agnCnfgAlrStartReportOn  
  INTEGER as agnCnfgAlrStartReportOff  

AgnCT1E1RingEntry  
SEQUENCE    
  Integer32 as agnCT1E1RingCnfgIdx  
  INTEGER as agnCT1E1RingPrimeSlot  
  Integer32 as agnCT1E1RingPrimePort  
  INTEGER as agnCT1E1RingSecSlot  
  Integer32 as agnCT1E1RingSecPort  
  Integer32 as agnCT1E1RingRecTime  
  RowStatus as agnCT1E1RingRowStatus  

AgnCmprEntry  
SEQUENCE    
  Integer32 as agnCmprTypIdx  
  Integer32 as agnCmprCnfgIdx  
  Integer32 as agnCmprVersion  
  OCTET STRING as agnCmprObj  

AgnDlciCmprEntry  
SEQUENCE    
  Integer32 as agnDlciCmprCnfgIdx  
  Integer32 as agnDlciCmprVersion  
  Integer32 as agnDlciCmprDlciIdx  
  OCTET STRING as agnDlciCmprObj  

AgnAlarmsCmprEntry  
SEQUENCE    
  Integer32 as agnAlarmsCmprVersion  
  Integer32 as agnAlarmsCmprAlarmIdx  
  OCTET STRING as agnAlarmsCmprObj  

AgnAlrBufCmprEntry  
SEQUENCE    
  Integer32 as agnAlrBufCmprVersion  
  Integer32 as agnAlrBufCmprAlarmIdx  
  OCTET STRING as agnAlrBufCmprObj  

AgnSCmprErrListEntry  
SEQUENCE    
  Integer32 as agnSCmprErrVersion  
  Integer32 as agnSCmprErrIdx  
  OCTET STRING as agnSCmprErrObj  

AgnTsCmprEntry  
SEQUENCE    
  Integer32 as agnTsCmprVerIdx  
  Integer32 as agnTsCmprCnfgIdx  
  Integer32 as agnTsCmprSlotIdx  
  Integer32 as agnTsCmprPortIdx  
  Integer32 as agnTsCmprPduIdx  
  OCTET STRING as agnTsCmprData  

AgnXCmprEntry  
SEQUENCE    
  Integer32 as agnXCmprTypIdx  
  Integer32 as agnXCmprVersion  
  Integer32 as agnXCmprIdx3  
  Integer32 as agnXCmprIdx4  
  Integer32 as agnXCmprIdx5  
  Integer32 as agnXCmprIdx6  
  Integer32 as agnXCmprIdx7  
  OCTET STRING as agnXCmprObj  

AgnLinkMapEntry  
SEQUENCE    
  Integer32 as mapLinkId  
  INTEGER as mapLinkSltIdx  
  INTEGER as mapLinkPrtIdx  
  INTEGER as mapLinkStatus  

AlrBufEntry  
SEQUENCE    
  Integer32 as alrBufIdx  
  DisplayString as alrBufDescription SIZE(0..255)  

AgnCAgendaEntry  
SEQUENCE    
  INTEGER as agnCAgendaCnfgIdx  
  INTEGER as agnCAgendaDayIdx  
  INTEGER as agnCAgendaDayCategory  

AgnCFlipNetEventsEntry  
SEQUENCE    
  INTEGER as agnCFlipNetEventsCnfgIdx  
  Integer32 as agnCFlipNetEventIdx  
  INTEGER as agnCFlipNetEventActive  
  INTEGER as agnCFlipNetEventType  
  Integer32 as agnCFlipNetEventNo  
  INTEGER as agnCFlipNetEventSlot  
  Integer32 as agnCFlipNetEventPort  
  Integer32 as agnCFlipNetEventISD  
  Integer32 as agnCFlipNetEventOSD  
  INTEGER as agnCFlipNetEventDayType  
  DisplayString as agnCFlipNetEventStartTime SIZE(5)  
  DisplayString as agnCFlipNetEventEndTime SIZE(5)  

AgnCFlipEntry  
SEQUENCE    
  INTEGER as agnCFlipCnfgIdx  
  Integer32 as agnCFlipIdx  
  INTEGER as agnCFlipActive  
  DisplayString as agnCFlipLogicalExp SIZE(1..20)  
  Integer32 as agnCFlipDbNo  
  INTEGER as agnCFlipDiscardDe  

AgnListDecodingEntry  
SEQUENCE    
  INTEGER as agnListDecodingType  
  Integer32 as agnListDecodingCode  
  DisplayString as agnListDecodingDescription SIZE(0..255)  
  INTEGER as agnListDecodingDefState  
  INTEGER as agnListDecodingSeverity  
  INTEGER as agnListDecodingAcmRelaySlt  
  INTEGER as agnListDecodingAcmRelayPrt  

AgnDlciEntry  
SEQUENCE    
  Integer32 as agnDlciCnfgIdx  
  INTEGER as agnDlciLSltIdx  
  Integer32 as agnDlciLPrtIdx  
  Integer32 as agnDlciLIdx  
  INTEGER as agnDlciHSltIdx  
  Integer32 as agnDlciHPrtIdx  
  Integer32 as agnDlciHIdx  
  INTEGER as agnDlciTxBc  
  INTEGER as agnDlciTxBe  
  INTEGER as agnDlciRxBc  
  INTEGER as agnDlciRxBe  
  Integer32 as agnDlciPriority  
  INTEGER as agnDlciStatus  
  INTEGER as agnDlciSpoofing  
  INTEGER as agnDlciFunnelEnable  
  INTEGER as agnDlciRoutingProtocol  
  RowStatus as agnDlciRowStatus  

AgnVoiceSwConfEntry  
SEQUENCE    
  INTEGER as agnVoiceSwConfIdx  
  DisplayString as agnVoiceSwConfZoneId  
  DisplayString as agnVoiceSwConfNodeId  
  Integer32 as agnVoiceSwConfNoOfHops  
  Integer32 as agnVoiceSwConfSidt  
  Integer32 as agnVoiceSwConfLidt  
  INTEGER as agnVoiceSwConfDialPlan  

AgnVoiceSwConfRtEntry  
SEQUENCE    
  INTEGER as agnVoiceSwConfRtDbId  
  Integer32 as agnVoiceSwConfRtIdx  
  DisplayString as agnVoiceSwConfRtDigits  
  INTEGER as agnVoiceSwConfRtAction  
  DisplayString as agnVoiceSwConfRtData  
  INTEGER as agnVoiceSwConfRtSlot  
  Integer32 as agnVoiceSwConfRtPort  
  Integer32 as agnVoiceSwConfRtDlci  
  RowStatus as agnVoiceSwConfRtRowStatus  
  Integer32 as agnVoiceSwConfRtMaxCalls  

AgnVoiceSwConfHGEntry  
SEQUENCE    
  INTEGER as agnVoiceSwConfHGdbIdx  
  Integer32 as agnVoiceSwConfHGIdx  
  INTEGER as agnVoiceSwConfHGConnect  
  Integer32 as agnVoiceSwConfHGExt  

AgnSigProfileEntry  
SEQUENCE    
  Integer32 as agnSigProfileCnfgIdx  
  Integer32 as agnSigProfileIdx  
  INTEGER as agnSigProfileRxTx  
  OCTET STRING as agnSigProfileABCD  

AgnSigProfEntry  
SEQUENCE    
  Integer32 as agnSigProfCnfgIdx  
  Integer32 as agnSigProfIdx  
  DisplayString as agnSigProfName  
  INTEGER as agnSigProfType  

SystemVoiceEntry  
SEQUENCE    
  Integer32 as systemVoiceConfIdx  
  INTEGER as systemVoiceNationalTone  

MdlSInstEntry  
SEQUENCE    
  INTEGER as mdlSInstSltIdx  
  INTEGER as mdlSInstCardType  
  DisplayString as mdlSHwVersion SIZE(0..255)  
  DisplayString as mdlSSwVersion SIZE(0..255)  
  INTEGER as mdlSAlrStatus  
  INTEGER as mdlSAlrStatusAll  
  INTEGER as mdlSMaskedAlrStat  
  INTEGER as mdlSMaskedAlrStatAll  
  INTEGER as mdlSTstStatusAll  
  INTEGER as mdlSClearAlrCmd  
  INTEGER as mdlSClearAllAlrCmd  

MdlSAlrEntry  
SEQUENCE    
  INTEGER as mdlSAlrSltIdx  
  Integer32 as mdlSAlrIdx  
  DisplayString as mdlSAlrCodeDescription SIZE(0..255)  
  Integer32 as mdlSAlrCode  
  INTEGER as mdlSAlrSeverity  
  INTEGER as mdlSAlrState  
  Integer32 as mdlSAlrCounter  
  INTEGER as mdlSAlrMask  
  INTEGER as mdlSAlrInvert  

MdlCPrgEntry  
SEQUENCE    
  Integer32 as mdlCCnfgIdx  
  INTEGER as mdlCSltIdx  
  INTEGER as mdlCPrgCardType  
  Integer32 as mdlCNoOfExternPrt  
  Integer32 as mdlCNoOfInternPrt  
  INTEGER as mdlCWorkMode  

MdlCmprEntry  
SEQUENCE    
  Integer32 as mdlCmprTypIdx  
  Integer32 as mdlCmprCnfgIdx  
  Integer32 as mdlCmprVersion  
  INTEGER as mdlCmprSltIdx  
  OCTET STRING as mdlCmprObj  

MdlAlarmsCmprEntry  
SEQUENCE    
  Integer32 as mdlAlarmsCmprVersion  
  Integer32 as mdlAlarmsCmprAlarmSlot  
  Integer32 as mdlAlarmsCmprAlarmIdx  
  OCTET STRING as mdlAlarmsCmprObj  

PrtSInstEntry  
SEQUENCE    
  INTEGER as prtSInstSltIdx  
  Integer32 as prtSInstPrtIdx  
  INTEGER as prtSInstPrtType  
  Integer32 as prtSInstIfIndex  
  INTEGER as prtSActiveStatus  
  INTEGER as prtSAlrStatus  
  INTEGER as prtSMaskedAlrStat  
  INTEGER as prtSClearAlrCmd  
  Integer32 as prtSTestMask  
  INTEGER as prtSTstCmd  
  Integer32 as prtSTstDuration  
  INTEGER as prtSBertClrCmd  
  Integer32 as prtSBertTstRslt  
  DisplayString as prtSInterfaceType SIZE(0..255)  
  OCTET STRING as prtSParamStatus  

PrtSAlrEntry  
SEQUENCE    
  INTEGER as prtSAlrSltIdx  
  Integer32 as prtSAlrPrtIdx  
  Integer32 as prtSAlrIdx  
  DisplayString as prtSAlrCodeDescription SIZE(0..255)  
  Integer32 as prtSAlrCode  
  INTEGER as prtSAlrSeverity  
  INTEGER as prtSAlrState  
  Integer32 as prtSAlrCounter  
  INTEGER as prtSAlrMask  
  INTEGER as prtSAlrInvert  

PrtFrStatisEntry  
SEQUENCE    
  INTEGER as prtFrStatisSltIdx  
  INTEGER as prtFrStatisPrtIdx  
  INTEGER as prtFrStatisInvIdx  
  Integer32 as prtFrTimeElapsed  
  Counter32 as prtFrRxTotalFrames  
  Counter32 as prtFrTxTotalFrames  
  Counter32 as prtFrRxTotalBytes  
  Counter32 as prtFrTxTotalBytes  
  Counter32 as prtFrRxMngFrames  
  Counter32 as prtFrTxMngFrames  
  Counter32 as prtFrRxDeFrames  
  Counter32 as prtFrTxDeFrames  
  Counter32 as prtFrRxDcrdCongDeFr  
  Counter32 as prtFrTxDcrdCongDeFr  
  Counter32 as prtFrRxDcrdCongAllFr  
  Counter32 as prtFrTxDcrdCongAllFr  
  Counter32 as prtFrRxFecn  
  Counter32 as prtFrTxFecn  
  Counter32 as prtFrRxBecn  
  Counter32 as prtFrTxBecn  
  Counter32 as prtFrRxBeViol  
  Counter32 as prtFrTxBeViol  
  Counter32 as prtFrRxBcViol  
  Counter32 as prtFrTxBcViol  

PrtCrStatisEntry  
SEQUENCE    
  INTEGER as prtCrStatisSltIdx  
  INTEGER as prtCrStatisPrtIdx  
  INTEGER as prtCrStatisInvIdx  
  Integer32 as prtCrTimeElapsed  
  Counter32 as prtCrRxTotalCells  
  Counter32 as prtCrTxTotalCells  
  Counter32 as prtCrRxDataCells  
  Counter32 as prtCrTxDataCells  

PrtDlciStatisEntry  
SEQUENCE    
  INTEGER as prtDlciSltIdx  
  INTEGER as prtDlciPrtIdx  
  Integer32 as prtDlciIdx  
  Counter32 as prtDlciRxDeFrames  
  Counter32 as prtDlciTxDeFrames  
  Counter32 as prtDlciRxDcrdCongDeFr  
  Counter32 as prtDlciTxDcrdCongDeFr  
  Counter32 as prtDlciRxDcrdCongAllFr  
  Counter32 as prtDlciTxDcrdCongAllFr  
  Counter32 as prtDlciTxFecn  
  Counter32 as prtDlciTxBecn  
  Counter32 as prtDlciRxBeViol  
  Counter32 as prtDlciTxBeViol  
  Counter32 as prtDlciRxBcViol  
  Counter32 as prtDlciTxBcViol  

PrtT1FdlMsgEntry  
SEQUENCE    
  INTEGER as prtT1FdlMsgSltIdx  
  INTEGER as prtT1FdlMsgPrtIdx  
  INTEGER as prtT1FdlMsgFdlTxRx  
  OCTET STRING as prtT1FdlMsg  

PrtExTsSplitEntry  
SEQUENCE    
  Integer32 as prtExTsCnfgIdx  
  INTEGER as prtExTsSltIdx  
  Integer32 as prtExTsPrtIdx  
  Integer32 as prtExTsIdx  
  Integer32 as prtExTsBit  
  INTEGER as prtExTsIConSlot  
  Integer32 as prtExTsIConPrt  
  INTEGER as prtExTsBitTest  
  OCTET STRING as prtExTsTxSignaling  
  OCTET STRING as prtExTsRxSignaling  

PrtAgendaBehaviourEntry  
SEQUENCE    
  Integer32 as prtAgendaBehaviourCnfgIdx  
  Integer32 as prtAgendaBehaviourSltIdx  
  Integer32 as prtAgendaBehaviourPrtIdx  
  INTEGER as prtAgendaBehaviourOnOff  

PrtCnfgAgendaEntry  
SEQUENCE    
  Integer32 as prtCnfgAgendaCnfgIdx  
  Integer32 as prtCnfgAgendaSltIdx  
  Integer32 as prtCnfgAgendaPrtIdx  
  INTEGER as prtCnfgAgendaDayIdx  
  Integer32 as prtCnfgAgendaSesId  
  Integer32 as prtCnfgAgendaFrom  
  Integer32 as prtCnfgAgendaTo  

PrtGenCnfgEntry  
SEQUENCE    
  Integer32 as prtGenCnfgIdx  
  INTEGER as prtGenCnfgSltIdx  
  Integer32 as prtGenCnfgPrtIdx  
  INTEGER as prtGenCnfgLinkToSlot  
  Integer32 as prtGenCnfgLinkToPort  
  Integer32 as prtGenCnfgPortId  

PrtCmprEntry  
SEQUENCE    
  Integer32 as prtCmprTypIdx  
  Integer32 as prtCmprCnfgIdx  
  Integer32 as prtCmprVersion  
  INTEGER as prtCmprSltIdx  
  Integer32 as prtCmprPrtIdx  
  OCTET STRING as prtCmprObj  
  OCTET STRING as prtCmprStatisticObj  

PrtDlciCmprEntry  
SEQUENCE    
  Integer32 as prtDlciCmprCnfgIdx  
  Integer32 as prtDlciCmprVersion  
  INTEGER as prtDlciCmprSltIdx  
  INTEGER as prtDlciCmprPrtIdx  
  Integer32 as prtDlciCmprDlciIdx  
  OCTET STRING as prtDlciCmprObj  

PrtAlarmsCmprEntry  
SEQUENCE    
  Integer32 as prtAlarmsCmprVersion  
  Integer32 as prtAlarmsCmprAlarmSlot  
  Integer32 as prtAlarmsCmprAlarmPort  
  Integer32 as prtAlarmsCmprAlarmIdx  
  OCTET STRING as prtAlarmsCmprObj  

PrtSExHsfStatEntry  
SEQUENCE    
  INTEGER as prtSExHsfSltIdx  
  INTEGER as prtSExHsfPrtIdx  
  INTEGER as prtSExHsfInterfaceTyp  
  INTEGER as prtSExHsfRts  

MdlPbxFramerCnfgEntry  
SEQUENCE    
  Integer32 as mdlPbxFraCnfgIdx  
  INTEGER as mdlPbxFraSltIdx  
  INTEGER as mdlPbxFraEnhEcho  
  INTEGER as mdlPbxFraTSGroupAss  
  INTEGER as mdlPbxFraSignalMode  
  OCTET STRING as mdlPbxFraSignalVector  
  OCTET STRING as mdlPbxFraSignalMask  
  INTEGER as mdlPbxFraFramerSlot  
  INTEGER as mdlPbxFraSignaling  
  Integer32 as mdlPbxFraTransSigTs  

PrtExClCnfgEntry  
SEQUENCE    
  Integer32 as prtExClCnfgIdx  
  INTEGER as prtExClSltIdx  
  INTEGER as prtExClPrtIdx  
  INTEGER as prtExClUsage  
  INTEGER as prtExClRate  
  INTEGER as prtExClDataBits  
  INTEGER as prtExClParity  
  INTEGER as prtExClStopBits  
  INTEGER as prtExClRoutingProtocol  
  INTEGER as prtExClEnabled  

PrtExPh1MlCnfgEntry  
SEQUENCE    
  Integer32 as prtExPh1MlCnfgIdx  
  INTEGER as prtExPh1MlSltIdx  
  INTEGER as prtExPh1MlPrtIdx  
  INTEGER as prtExPh1MlConnect  
  INTEGER as prtExPh1MlLineType  
  INTEGER as prtExPh1MlLineCode  
  INTEGER as prtExPh1MlLineLen  
  INTEGER as prtExPh1MlRestoreTime  
  INTEGER as prtExPh1MlTxGain  
  INTEGER as prtExPh1MlRxSensitivity  
  Integer32 as prtExPh1MlIdleCode  
  INTEGER as prtExPh1MlTdmTrunk  
  INTEGER as prtExPh1MlClkMode  
  INTEGER as prtExPh1MlMfClkSrcSlt  
  INTEGER as prtExPh1MlMfClkSrcPrt  
  INTEGER as prtExPh1MlFdlType  
  INTEGER as prtExPh1MlInbandMng  
  INTEGER as prtExPh1MlInbandMngRate  
  INTEGER as prtExPh1MlRedundType  
  INTEGER as prtExPh1MlRedundSlot  
  INTEGER as prtExPh1MlRedundPort  
  Integer32 as prtExPh1MlRedundRecTime  
  INTEGER as prtExPh1MlInbandMngRoutProt  
  INTEGER as prtExPh1MlIfType  
  INTEGER as prtExPh1MlMultiplier  
  INTEGER as prtExPh1MlSupportedTS  

PrtExPh1MlTsEntry  
SEQUENCE    
  Integer32 as prtExPh1MlTsCnfgIdx  
  INTEGER as prtExPh1MlTsSltIdx  
  INTEGER as prtExPh1MlTsPrtIdx  
  Integer32 as prtExPh1MlTsIdx  
  INTEGER as prtExPh1MlTsIConSlot  
  Integer32 as prtExPh1MlTsIConPrt  
  Integer32 as prtExPh1MlTsIConTs  
  OBJECT IDENTIFIER as prtExPh1MlTsExt  
  INTEGER as prtExPh1MlTsTest  
  INTEGER as prtExPh1MlTsType  
  INTEGER as prtExPh1MlTsBundle  
  Integer32 as prtExPh1MlTsTestDuration  

PrtInPh1MlCnfgEntry  
SEQUENCE    
  Integer32 as prtInPh1MlCnfgIdx  
  INTEGER as prtInPh1MlSltType  
  Integer32 as prtInPh1MlPrtIdx  
  INTEGER as prtInPh1MlConnect  
  INTEGER as prtInPh1MlRate  
  INTEGER as prtInPh1MlProtocol  
  INTEGER as prtInPh1MlConnectionTyp  
  INTEGER as prtInPh1MlCongResponse  
  Integer32 as prtInPh1MlCongLevel  
  INTEGER as prtInPh1MlTc  
  INTEGER as prtInPh1MlFlowControl  
  INTEGER as prtInPh1MlSegment  
  INTEGER as prtInPh1MlFrMngProt  
  Integer32 as prtInPh1MlEnqPeriod  
  Integer32 as prtInPh1MlFullRptPeriod  
  Integer32 as prtInPh1MlFrWindowSize  
  Integer32 as prtInPh1MlErrorsThreshold  
  Integer32 as prtInPh1MlMaxIdleTime  
  INTEGER as prtInPh1MlBearerCh  
  INTEGER as prtInPh1MlAssociatedExCh  
  INTEGER as prtInPh1MlClockEncoding  
  Integer32 as prtInPh1MlMinSeparators  
  INTEGER as prtInPh1MlCcittCrc  
  INTEGER as prtInPh1MlFrameSeparator  

PrtInPh1MlDlciEntry  
SEQUENCE    
  Integer32 as prtInPh1MlDlciCnfgIdx  
  INTEGER as prtInPh1MlDlciSltIdx  
  INTEGER as prtInPh1MlDlciPrtIdx  
  Integer32 as prtInPh1MlDlciIdx  
  INTEGER as prtInPh1MlDlciValid  
  INTEGER as prtInPh1MlDlciIConSlt  
  INTEGER as prtInPh1MlDlciIConPrt  
  Integer32 as prtInPh1MlDlciIConDlci  
  INTEGER as prtInPh1MlDlciTxBc  
  INTEGER as prtInPh1MlDlciTxBe  
  INTEGER as prtInPh1MlDlciRxBc  
  INTEGER as prtInPh1MlDlciRxBe  
  Integer32 as prtInPh1MlDlciPriority  
  INTEGER as prtInPh1MlDlciStatus  

PrtPhMlCnfgEntry  
SEQUENCE    
  Integer32 as prtPhMlCnfgIdx  
  INTEGER as prtPhMlSltIdx  
  INTEGER as prtPhMlPrtIdx  
  INTEGER as prtPhMlConnect  
  INTEGER as prtPhMlRate  
  INTEGER as prtPhMlCAS  
  INTEGER as prtPhMlClockMode  
  INTEGER as prtPhMlSatBuffer  
  INTEGER as prtPhMlDialProcess  
  Integer32 as prtPhMlSyncRestore  
  INTEGER as prtPhMlBus  
  INTEGER as prtPhMlMfSyncSlot  

PrtLogicalCnfgEntry  
SEQUENCE    
  Integer32 as prtLogicalCnfgIdx  
  INTEGER as prtLogicalSltIdx  
  Integer32 as prtLogicalPrtIdx  
  INTEGER as prtLogicalConnect  
  INTEGER as prtLogicalFunction  
  RowStatus as prtLogicalRowStatus  

LinkSelectorCnfgEntry  
SEQUENCE    
  Integer32 as linkSelectorCnfgIdx  
  INTEGER as linkSelectorSltIdx  
  Integer32 as linkSelectorPrtIdx  
  Integer32 as linkSelectorMaxIdleTime  
  INTEGER as linkSelectorMode  
  INTEGER as linkSelectorRevert  
  Integer32 as linkSelectorMinBUSession  

LinkSelectorPLinkEntry  
SEQUENCE    
  Integer32 as pLinkCnfgIdx  
  INTEGER as pLinkSltIdx  
  Integer32 as pLinkPrtIdx  
  Integer32 as pLinkIdx  
  INTEGER as pLinkSlotNu  
  Integer32 as pLinkPortNu  
  Integer32 as pLinkPrioNu  
  INTEGER as pLinkVRate  

PrtExPhPlCnfgEntry  
SEQUENCE    
  Integer32 as prtExPhPlCnfgIdx  
  INTEGER as prtExPhPlSltIdx  
  INTEGER as prtExPhPlPrtIdx  
  INTEGER as prtExPhPlConnect  
  INTEGER as prtExPhPlHRate  
  INTEGER as prtExPhPlLRate  
  INTEGER as prtExPhPlProtocol  
  INTEGER as prtExPhPlConnectionTyp  
  INTEGER as prtExPhPlClkMode  
  INTEGER as prtExPhPlDceClkSrc  
  INTEGER as prtExPhPlCongResponse  
  Integer32 as prtExPhPlCongLevel  
  INTEGER as prtExPhPlTc  
  INTEGER as prtExPhPlFlowControl  
  INTEGER as prtExPhPlDcdRts  
  INTEGER as prtExPhPlDcdRtsControlPath  
  INTEGER as prtExPhPlDataBits  
  INTEGER as prtExPhPlParity  
  INTEGER as prtExPhPlStopBits  
  Integer32 as prtExPhPlLXon  
  Integer32 as prtExPhPlLXoff  
  INTEGER as prtExPhPlFrMngProt  
  Integer32 as prtExPhPlEnqPeriod  
  Integer32 as prtExPhPlFullRptPeriod  
  Integer32 as prtExPhPlFrWindowSize  
  Integer32 as prtExPhPlErrorsThreshold  
  INTEGER as prtExPhPlPvcCreateMsg  
  INTEGER as prtExPhPlCllmMsg  
  INTEGER as prtExPhPlProtDelayLevel  
  INTEGER as prtExPhPlClockEncoding  
  Integer32 as prtExPhPlMinSeparators  
  INTEGER as prtExPhPlCcittCrc  
  INTEGER as prtExPhPlFrameSeparator  
  Integer32 as prtExPhPlIdleCode  
  Integer32 as prtExPhPlJitter  

PrtExPhPlDlciEntry  
SEQUENCE    
  Integer32 as prtExPhPlDlciCnfgIdx  
  INTEGER as prtExPhPlDlciSltIdx  
  INTEGER as prtExPhPlDlciPrtIdx  
  Integer32 as prtExPhPlDlciIdx  
  INTEGER as prtExPhPlDlciValid  
  INTEGER as prtExPhPlDlciIConSlt  
  INTEGER as prtExPhPlDlciIConPrt  
  Integer32 as prtExPhPlDlciIConDlci  
  INTEGER as prtExPhPlDlciTxBc  
  INTEGER as prtExPhPlDlciTxBe  
  INTEGER as prtExPhPlDlciRxBc  
  INTEGER as prtExPhPlDlciRxBe  
  Integer32 as prtExPhPlDlciPriority  
  INTEGER as prtExPhPlDlciStatus  

PrtExPhPlModemEntry  
SEQUENCE    
  Integer32 as prtExPhPlModemCnfgIdx  
  INTEGER as prtExPhPlModemSltIdx  
  INTEGER as prtExPhPlModemPrtIdx  
  INTEGER as prtExPhPlModemStatus  
  INTEGER as prtExPhPlModemActivate  
  Integer32 as prtExPhPlModemMaxIdleTime  
  Integer32 as prtExPhPlModemTimeBtwnCalls  
  Integer32 as prtExPhPlModemCallDelay  

PrtExLs2CnfgEntry  
SEQUENCE    
  Integer32 as prtExLs2CnfgIdx  
  INTEGER as prtExLs2SltIdx  
  INTEGER as prtExLs2PrtIdx  
  INTEGER as prtExLs2Connect  
  INTEGER as prtExLs2Rate  
  INTEGER as prtExLs2ClkMode  
  INTEGER as prtExLs2Cts  
  INTEGER as prtExLs2Dcd  
  Integer32 as prtExLs2EnvIdx  

PrtInLs2CnfgEntry  
SEQUENCE    
  Integer32 as prtInLs2CnfgIdx  
  INTEGER as prtInLs2SltIdx  
  INTEGER as prtInLs2PrtIdx  
  INTEGER as prtInLs2Connect  
  Integer32 as prtInLs2Group  
  Integer32 as prtInLs2Member  
  INTEGER as prtInLs2LinkTo  
  INTEGER as prtInLs2EnvAssign  

PrtVc2CnfgEntry  
SEQUENCE    
  Integer32 as prtVc2CnfgIdx  
  INTEGER as prtVc2SltIdx  
  Integer32 as prtVc2PrtIdx  
  INTEGER as prtExVc2Connect  
  Integer32 as prtExVc2TransGain  
  Integer32 as prtExVc2ReceiveGain  
  INTEGER as prtExVc2Wire  
  INTEGER as prtExVc2CodingLaw  
  INTEGER as prtExVc2Sig  
  INTEGER as prtExVc2Oos  
  INTEGER as prtExVc2LinkTo  
  INTEGER as prtExVc2OperMode  
  INTEGER as prtExVc2SigProfile  
  INTEGER as prtExVc2CallEnable  
  INTEGER as prtExVc2R2Delay  
  INTEGER as prtExVc2CasStd  
  INTEGER as prtExVc2EchoCanceler  
  INTEGER as prtExVc2IfType  
  INTEGER as prtExVc2Encoding  
  OCTET STRING as prtExVc2TxBitCode  
  OCTET STRING as prtExVc2RxBitOutput  
  INTEGER as prtExVc2MeterRate  
  INTEGER as prtExVc2IfSignaling  
  INTEGER as prtExVc2SeizeAck  
  INTEGER as prtExVc2EandMType  
  INTEGER as prtExVc2RemType  
  INTEGER as prtExVc2ConvTime  
  INTEGER as prtExVc2SigFeedback  
  INTEGER as prtExVc2EchoCancelerModule  

PrtHsfCnfgEntry  
SEQUENCE    
  Integer32 as prtHsfCnfgIdx  
  INTEGER as prtHsfSltIdx  
  INTEGER as prtHsfPrtIdx  
  INTEGER as prtExHsfConnect  
  INTEGER as prtExHsfRate  
  INTEGER as prtExHsfClkMode  
  INTEGER as prtExHsfCts  
  INTEGER as prtExHsfFifoSize  
  INTEGER as prtExHsfLinkTo  
  INTEGER as prtExHsfOperMode  
  INTEGER as prtExHsfInbandLoopback  
  INTEGER as prtExHsfClkPolarity  
  INTEGER as prtExHsfControlSignal  

PrtExHs4CnfgEntry  
SEQUENCE    
  Integer32 as prtExHs4CnfgIdx  
  INTEGER as prtExHs4SltIdx  
  INTEGER as prtExHs4PrtIdx  
  INTEGER as prtExHs4Connect  
  INTEGER as prtExHs4LineType  
  INTEGER as prtExHs4LineCode  
  INTEGER as prtExHs4LineLen  
  INTEGER as prtExHs4RestoreT  
  INTEGER as prtExHs4OosSig  
  INTEGER as prtExHs4OosCode  
  Integer32 as prtExHs4IdleCode  
  INTEGER as prtExHs4MfClkSrcSlt  
  INTEGER as prtExHs4MfClkSrcPrt  

PrtExHs4TsEntry  
SEQUENCE    
  Integer32 as prtExHs4TsCnfgIdx  
  INTEGER as prtExHs4TsSltIdx  
  INTEGER as prtExHs4TsPrtIdx  
  Integer32 as prtExHs4TsIdx  
  INTEGER as prtExHs4TsIConSlot  
  INTEGER as prtExHs4TsIConPrt  
  Integer32 as prtExHs4TsIConTs  

PrtExHsiCnfgEntry  
SEQUENCE    
  Integer32 as prtExHsiCnfgIdx  
  INTEGER as prtExHsiSltIdx  
  Integer32 as prtExHsiPrtIdx  
  INTEGER as prtExHsiConnect  
  INTEGER as prtExHsiRate  
  INTEGER as prtExHsiLinkTo  
  INTEGER as prtExHsiInterface  
  INTEGER as prtExHsiActType  

PrtInHsiCnfgEntry  
SEQUENCE    
  Integer32 as prtInHsiCnfgIdx  
  INTEGER as prtInHsiSltIdx  
  Integer32 as prtInHsiPrtIdx  
  INTEGER as prtInHsiConnect  
  INTEGER as prtInHsiRate  
  Integer32 as prtInHsiConcentratedTo  

PrtExHsrCnfgEntry  
SEQUENCE    
  Integer32 as prtExHsrCnfgIdx  
  INTEGER as prtExHsrSltIdx  
  Integer32 as prtExHsrPrtIdx  
  INTEGER as prtExHsrConnect  
  INTEGER as prtExHsrProtocol  
  INTEGER as prtExHsrRate  
  INTEGER as prtExHsrDataBits  
  INTEGER as prtExHsrParity  
  INTEGER as prtExHsrStopBits  
  INTEGER as prtExHsrCts  
  INTEGER as prtExHsrClkMode  
  INTEGER as prtExHsrLinkTo  
  INTEGER as prtExHsrDcdDsr  
  INTEGER as prtExHsrOperMode  
  INTEGER as prtExHsrRtsDtr  
  INTEGER as prtExHsrLlbEnable  
  INTEGER as prtExHsrRlbEnable  
  INTEGER as prtExHsrRateAdapt  
  INTEGER as prtExHsrRemoteModem  

PrtExMbeCnfgEntry  
SEQUENCE    
  Integer32 as prtExMbeCnfgIdx  
  INTEGER as prtExMbeSltIdx  
  INTEGER as prtExMbePrtIdx  
  INTEGER as prtExMbeLan  

PrtInMbeCnfgEntry  
SEQUENCE    
  Integer32 as prtInMbeCnfgIdx  
  INTEGER as prtInMbeSltIdx  
  INTEGER as prtInMbePrtIdx  
  INTEGER as prtInMbeConnect  
  INTEGER as prtInMbeRate  
  INTEGER as prtInMbeLinkTo  

PrtExTreCnfgEntry  
SEQUENCE    
  Integer32 as prtExTreCnfgIdx  
  INTEGER as prtExTreSltIdx  
  INTEGER as prtExTrePrtIdx  
  INTEGER as prtExTreLan  
  INTEGER as prtExTreLanRate  

PrtInTreCnfgEntry  
SEQUENCE    
  Integer32 as prtInTreCnfgIdx  
  INTEGER as prtInTreSltIdx  
  INTEGER as prtInTrePrtIdx  
  INTEGER as prtInTreConnect  
  INTEGER as prtInTreRate  
  INTEGER as prtInTreLinkTo  

PrtExPVc4CnfgEntry  
SEQUENCE    
  Integer32 as prtExPVc4CnfgIdx  
  INTEGER as prtExPVc4SltIdx  
  INTEGER as prtExPVc4PrtIdx  
  INTEGER as prtExPVc4PrtType  
  INTEGER as prtExPVc4Connect  
  INTEGER as prtExPVc4IfType  
  Integer32 as prtExPVc4TxGain  
  Integer32 as prtExPVc4RxGain  
  INTEGER as prtExPVc4MaxRate  
  INTEGER as prtExPVc4Tc  
  INTEGER as prtExPVc4Oos  
  INTEGER as prtExPVc4EchoCanceler  
  Integer32 as prtExPVc4VarDelay  
  Integer32 as prtExPVc4CongLevel  
  INTEGER as prtExPVc4Wire  
  INTEGER as prtExPVc4ExtensionType  
  DisplayString as prtExPVc4ExtensionNumber  
  INTEGER as prtExPVc4OutPulsing  
  INTEGER as prtExPVc4HuntGroupMb  
  Integer32 as prtExPVc4HuntGroupIdx  
  INTEGER as prtExPVc4AutoFaxMode  
  INTEGER as prtExPVc4FaxRate  
  INTEGER as prtExPVc4SeizeAck  
  INTEGER as prtExPVc4SignalingProtocol  
  Integer32 as prtExPVc4DelayStart  
  Integer32 as prtExPVc4WinkMinDuration  
  Integer32 as prtExPVc4WinkMaxDuration  
  INTEGER as prtExPVc4GenerateTone  
  INTEGER as prtExPVc4CodingLaw  
  INTEGER as prtExPVc4GenerateRingBack  
  Integer32 as prtExPVc4ChannelId  
  INTEGER as prtExPVc4PortConnection  
  INTEGER as prtExPVc4CoderAndRate  
  DisplayString as prtExPVc4DestinationNum  
  INTEGER as prtExPVc4DtmfRelay  
  Integer32 as prtExPVc4DiscOnSilence  
  INTEGER as prtExPVc4DynamicJitter  
  INTEGER as prtExPVc4EandMType  

PrtExPVc4DlciEntry  
SEQUENCE    
  Integer32 as prtExPVc4DlciCnfgIdx  
  INTEGER as prtExPVc4DlciSltIdx  
  INTEGER as prtExPVc4DlciPrtIdx  
  INTEGER as prtExPVc4DlciValid  
  INTEGER as prtExPVc4DlciIConSlt  
  INTEGER as prtExPVc4DlciIConPrt  
  Integer32 as prtExPVc4DlciIConDlci  
  INTEGER as prtExPVc4DlciTxBc  
  INTEGER as prtExPVc4DlciTxBe  
  INTEGER as prtExPVc4DlciRxBc  
  INTEGER as prtExPVc4DlciRxBe  
  Integer32 as prtExPVc4DlciPriority  
  INTEGER as prtExPVc4DlciStatus  

PrtExLs6CnfgEntry  
SEQUENCE    
  Integer32 as prtExLs6CnfgIdx  
  INTEGER as prtExLs6SltIdx  
  INTEGER as prtExLs6PrtIdx  
  INTEGER as prtExLs6Connect  
  INTEGER as prtExLs6Protocol  
  INTEGER as prtExLs6Rate  
  INTEGER as prtExLs6ClkMode  
  INTEGER as prtExLs6CtrlSignal  
  INTEGER as prtExLs6DataBits  
  INTEGER as prtExLs6Cts  
  INTEGER as prtExLs6LinkToInternal  

PrtExLs6VCnfgEntry  
SEQUENCE    
  Integer32 as prtExLs6VCnfgIdx  
  INTEGER as prtExLs6VSltIdx  
  INTEGER as prtExLs6VPrtIdx  
  INTEGER as prtExLs6VConnect  
  INTEGER as prtExLs6VRate  
  INTEGER as prtExLs6VEchoCanceler  
  INTEGER as prtExLs6VIfType  
  Integer32 as prtExLs6VTxGain  
  Integer32 as prtExLs6VRxGain  
  INTEGER as prtExLs6VOos  

PrtInLs6CnfgEntry  
SEQUENCE    
  Integer32 as prtInLs6CnfgIdx  
  INTEGER as prtInLs6SltIdx  
  INTEGER as prtInLs6PrtIdx  
  INTEGER as prtInLs6Connect  
  INTEGER as prtInLs6TandemMode  
  INTEGER as prtInLs6Rate  
  INTEGER as prtInLs6RemoteType  
  INTEGER as prtInLs6LinkTo  

PrtExVc3CnfgEntry  
SEQUENCE    
  Integer32 as prtExVc3CnfgIdx  
  INTEGER as prtExVc3SltIdx  
  INTEGER as prtExVc3PrtIdx  
  INTEGER as prtExVc3Connect  
  Integer32 as prtExVc3TransGain  
  Integer32 as prtExVc3ReceiveGain  
  INTEGER as prtExVc3Wire  
  INTEGER as prtExVc3Rate  
  INTEGER as prtExVc3EchoCanceler  

PrtInVc3CnfgEntry  
SEQUENCE    
  Integer32 as prtInVc3CnfgIdx  
  INTEGER as prtInVc3SltIdx  
  INTEGER as prtInVc3PrtIdx  
  INTEGER as prtInVc3Connect  
  INTEGER as prtInVc3Rate  
  INTEGER as prtInVc3Oos  
  INTEGER as prtInVc3LinkTo  

PrtExVcPbxCnfgEntry  
SEQUENCE    
  Integer32 as prtExVcPbxCnfgIdx  
  INTEGER as prtExVcPbxSltIdx  
  INTEGER as prtExVcPbxPrtIdx  
  INTEGER as prtExVcPbxConnect  
  INTEGER as prtExVcPbxGroup  
  INTEGER as prtExVcPbxTransparent  
  Integer32 as prtExVcPbxTransSignalTs  
  INTEGER as prtExVcPbxFrame  
  INTEGER as prtExVcPbxRestoreTime  
  INTEGER as prtExVcPbxLineCode  
  INTEGER as prtExVcPbxLineLength  
  INTEGER as prtExVcPbxLinkTo  
  INTEGER as prtExVcPbxSignalOper  
  INTEGER as prtExVcPbxIdleCode  

PrtIn1p6VcPbxCnfgEntry  
SEQUENCE    
  Integer32 as prtIn1p6VcPbxCnfgIdx  
  INTEGER as prtIn1p6VcPbxSltIdx  
  INTEGER as prtIn1p6VcPbxPrtIdx  
  INTEGER as prtIn1p6VcPbxConnect  
  INTEGER as prtIn1p6VcPbxRate  
  INTEGER as prtIn1p6VcPbxEchoCanceler  
  Integer32 as prtIn1p6VcPbxPabxTs  

PrtIn7p8VcPbxCnfgEntry  
SEQUENCE    
  Integer32 as prtIn7p8VcPbxCnfgIdx  
  INTEGER as prtIn7p8VcPbxSltIdx  
  INTEGER as prtIn7p8VcPbxPrtIdx  
  INTEGER as prtIn7p8VcPbxConnect  
  INTEGER as prtIn7p8VcPbxMode  
  INTEGER as prtIn7p8VcPbxRate  
  INTEGER as prtIn7p8VcPbxSignalMode  
  INTEGER as prtIn7p8VcPbxOos  
  INTEGER as prtIn7p8VcPbxLinkTo  

PrtExVcPbxTsEntry  
SEQUENCE    
  Integer32 as prtExVcPbxTsCnfgIdx  
  INTEGER as prtExVcPbxTsSltIdx  
  INTEGER as prtExVcPbxTsPrtIdx  
  Integer32 as prtExVcPbxTsIdx  
  INTEGER as prtExVcPbxTsMode  
  INTEGER as prtExVcPbxTsIConSlot  
  INTEGER as prtExVcPbxTsIConPrt  

PrtIsdnCnfgEntry  
SEQUENCE    
  Integer32 as prtIsdnCnfgIdx  
  INTEGER as prtIsdnSltIdx  
  Integer32 as prtIsdnPrtIdx  
  INTEGER as prtIsdnConnect  
  INTEGER as prtIsdnSignalingProtocol  
  INTEGER as prtIsdnBasicRateLineTopology  
  INTEGER as prtIsdnMode  
  INTEGER as prtIsdnFilter  
  INTEGER as prtIsdnSimultaneousCall  
  Integer32 as prtIsdnNumOfAbstractTerm  
  INTEGER as prtIsdnSwitchMode  
  INTEGER as prtIsdnAbSide  
  INTEGER as prtIsdnQsigRole  
  INTEGER as prtIsdnInterface  
  INTEGER as prtIsdnCallMode  
  INTEGER as prtIsdnCallBackTimeout  

PrtIsdnEndpointEntry  
SEQUENCE    
  Integer32 as prtIsdnEndpointCnfgIdx  
  INTEGER as prtIsdnEndpointSltIdx  
  Integer32 as prtIsdnEndpointPrtIdx  
  INTEGER as prtIsdnEndpointIdx  
  INTEGER as prtIsdnEndpointTeiType  
  Integer32 as prtIsdnEndpointTeiValue  
  DisplayString as prtIsdnEndpointSpid  
  INTEGER as prtIsdnEndpointBearerCh  
  RowStatus as prtIsdnEndpointRowStatus  

PrtIsdnDirectoryEntry  
SEQUENCE    
  Integer32 as prtIsdnDirectoryCnfgIdx  
  INTEGER as prtIsdnDirectorySltIdx  
  Integer32 as prtIsdnDirectoryPrtIdx  
  DisplayString as prtIsdnDirectoryLocalAddr  
  DisplayString as prtIsdnDirectoryLocalSubAddr  
  DisplayString as prtIsdnDirectoryRemoteAddr  
  DisplayString as prtIsdnDirectoryRemoteSubAddr  
  Integer32 as prtIsdnDirectoryPrtNu  
  Integer32 as prtIsdnDirectoryTeiId  
  RowStatus as prtIsdnDirectoryRowStatus  
  DisplayString as prtIsdnDirectoryLocalAddr2  
  DisplayString as prtIsdnDirectoryLocalSubAddr2  
  DisplayString as prtIsdnDirectoryRemoteAddr2  
  DisplayString as prtIsdnDirectoryRemoteSubAddr2  

PrtFrPlusCnfgEntry  
SEQUENCE    
  Integer32 as prtFrPlusCnfgIdx  
  INTEGER as prtFrPlusSltIdx  
  Integer32 as prtFrPlusPrtIdx  
  OCTET STRING as prtFrPlusNotSegmentedPriorities  

PrtMl4CnfgEntry  
SEQUENCE    
  Integer32 as prtMl4CnfgIdx  
  INTEGER as prtMl4SltIdx  
  INTEGER as prtMl4PrtIdx  
  INTEGER as prtMl4SigProfile  
  INTEGER as prtMl4CGA  
  INTEGER as prtMl4Oos  
  OCTET STRING as prtMl4VoiceOos  
  OCTET STRING as prtMl4DataOos  
  INTEGER as prtMl4Service  
  IpAddress as prtMl4IpAddress  
  IpAddress as prtMl4IpMask  
  INTEGER as prtMl4SignalingMode  
  INTEGER as prtMl4EchoCanceler  
  INTEGER as prtMl4OosErrorSource  
  Integer32 as prtMl4OosEntryThreshold  
  Integer32 as prtMl4OosExitThreshold  

PrtAcmCnfgEntry  
SEQUENCE    
  Integer32 as prtAcmCnfgIdx  
  INTEGER as prtAcmSltIdx  
  INTEGER as prtAcmPrtIdx  
  INTEGER as prtAcmConnect  
  INTEGER as prtAcmActiveState  
  DisplayString as prtAcmAlrString  

PrtE2CnfgEntry  
SEQUENCE    
  Integer32 as prtE2CnfgIdx  
  INTEGER as prtE2SltIdx  
  INTEGER as prtE2PrtIdx  
  INTEGER as prtE2Connect  
  INTEGER as prtE2MngOnNationalBit  

EthIfEntry  
SEQUENCE    
  Integer32 as ethIfIdx  
  INTEGER as ethMode  
  INTEGER as ethBridgingMode  
  INTEGER as ethEncapsulationCRCMode  
  INTEGER as ethBackPressure  
  INTEGER as ethLimit4  
  INTEGER as ethSkipInitReset  
  INTEGER as ethMulticastBlock  
  INTEGER as ethBroadcastBlock  
  INTEGER as ethSpeed  

EthIfCurrentEntry  
SEQUENCE    
  Integer32 as ethIfCurrentIndex  
  OCTET STRING as ethIfCurrentStatus  
  Gauge32 as ethIfCurrentInFrames  
  Gauge32 as ethIfCurrentInOctets  
  Gauge32 as ethIfCurrentAlignmentErrors  
  Gauge32 as ethIfCurrentFCSErrors  
  Gauge32 as ethIfCurrentLengthError  
  Gauge32 as ethIfCurrentOutFrames  
  Gauge32 as ethIfCurrentOutOctets  
  Gauge32 as ethIfCurrentSingleCollisionFrames  
  Gauge32 as ethIfCurrentMultipleCollisionFrames  
  Gauge32 as ethIfCurrentDeferredTransmissions  
  Gauge32 as ethIfCurrentLateCollisions  
  Gauge32 as ethIfCurrentCarrierSenseErrors  

EthIfIntervalEntry  
SEQUENCE    
  Integer32 as ethIfIntervalIndex  
  Integer32 as ethIfIntervalNumber  
  OCTET STRING as ethIfIntervalStatus  
  Gauge32 as ethIfIntervalInFrames  
  Gauge32 as ethIfIntervalInOctets  
  Gauge32 as ethIfIntervalAlignmentErrors  
  Gauge32 as ethIfIntervalFCSErrors  
  Gauge32 as ethIfIntervalLengthError  
  Gauge32 as ethIfIntervalOutFrames  
  Gauge32 as ethIfIntervalOutOctets  
  Gauge32 as ethIfIntervalSingleCollisionFrames  
  Gauge32 as ethIfIntervalMultipleCollisionFrames  
  Gauge32 as ethIfIntervalDeferredTransmissions  
  Gauge32 as ethIfIntervalLateCollisions  
  Gauge32 as ethIfIntervalCarrierSenseErrors  

AgnTsEntry  
SEQUENCE    
  Integer32 as agnTsCnfgIdx  
  INTEGER as agnTsSltIdx  
  Integer32 as agnTsPrtIdx  
  Integer32 as agnTsIdx  
  Integer32 as agnTsBitIdx  
  INTEGER as agnTsConSltIdx  
  Integer32 as agnTsConPrtIdx  
  Integer32 as agnTsConIdx  
  INTEGER as agnTsType  
  RowStatus as agnTsRowStatus  
  INTEGER as agnTsDirection  

PktSwchRoutSEntry  
SEQUENCE    
  Integer32 as pktSwchRoutIdS  
  DisplayString as pktSwchRoutAddressS  
  DisplayString as pktSwchRoutDestLink1S  
  DisplayString as pktSwchRoutDestLink2S  
  DisplayString as pktSwchRoutDestLink3S  
  Integer32 as pktSwchRoutLinkPrio1S  
  Integer32 as pktSwchRoutLinkPrio2S  
  Integer32 as pktSwchRoutLinkPrio3S  
  INTEGER as pktSwchRoutSearchStatusS  
  INTEGER as pktSwchRoutStatusS  

PktSwchRoutAEntry  
SEQUENCE    
  Integer32 as pktSwchRoutIdA  
  DisplayString as pktSwchRoutAddressA  
  DisplayString as pktSwchRoutDestLink1A  
  DisplayString as pktSwchRoutDestLink2A  
  DisplayString as pktSwchRoutDestLink3A  
  Integer32 as pktSwchRoutLinkPrio1A  
  Integer32 as pktSwchRoutLinkPrio2A  
  Integer32 as pktSwchRoutLinkPrio3A  
  INTEGER as pktSwchRoutSearchStatusA  

PktSwchPvcSEntry  
SEQUENCE    
  Integer32 as pktSwchPvcNumS  
  Integer32 as pktSwchPvcSrcLinkS  
  DisplayString as pktSwchPvcSrcLcnS  
  Integer32 as pktSwchPvcDstLinkS  
  Integer32 as pktSwchPvcDstLcnS  
  INTEGER as pktSwchPvcStatusS  

PktSwchPvcAEntry  
SEQUENCE    
  Integer32 as pktSwchPvcNumA  
  Integer32 as pktSwchPvcSrcLinkA  
  DisplayString as pktSwchPvcSrcLcnA  
  Integer32 as pktSwchPvcDstLinkA  
  Integer32 as pktSwchPvcDstLcnA  

PktSwchNuiSEntry  
SEQUENCE    
  Integer32 as pktSwchNuiIndexS  
  Integer32 as pktSwchNuiGroupIdS  
  DisplayString as pktSwchNuiInPasswdS  
  Integer32 as pktSwchNuiOutPasswdPointerS  
  DisplayString as pktSwchNuiInAddrS  
  Integer32 as pktSwchNuiOutAddrPointerS  
  INTEGER as pktSwchNuiStatusS  

PktSwchNuiAEntry  
SEQUENCE    
  Integer32 as pktSwchNuiIndexA  
  Integer32 as pktSwchNuiGroupIdA  
  DisplayString as pktSwchNuiInPasswdA  
  Integer32 as pktSwchNuiOutPasswdPointerA  
  DisplayString as pktSwchNuiInAddrA  
  Integer32 as pktSwchNuiOutAddrPointerA  
  INTEGER as pktSwchNuiStatusA  

PktSwchNuiOutPasswdSEntry  
SEQUENCE    
  Integer32 as pktSwchNuiOutPasswdIndexS  
  DisplayString as pktSwchNuiOutPasswdValueS  
  INTEGER as pktSwchNuiOutPasswdStatusS  

PktSwchNuiOutPasswdAEntry  
SEQUENCE    
  Integer32 as pktSwchNuiOutPasswdIndexA  
  DisplayString as pktSwchNuiOutPasswdValueA  
  INTEGER as pktSwchNuiOutPasswdStatusA  

PktSwchNuiOutAddrSEntry  
SEQUENCE    
  Integer32 as pktSwchNuiOutAddrIndexS  
  DisplayString as pktSwchNuiOutAddrValueS  
  INTEGER as pktSwchNuiOutAddrStatusS  

PktSwchNuiOutAddrAEntry  
SEQUENCE    
  Integer32 as pktSwchNuiOutAddrIndexA  
  DisplayString as pktSwchNuiOutAddrValueA  
  INTEGER as pktSwchNuiOutAddrStatusA  

PktSwchMngX25Entry  
SEQUENCE    
  Integer32 as pktSwchMngID  
  IpAddress as pktSwchMngIP  
  DisplayString as pktSwchMngPhyAddr  
  Integer32 as pktSwchTrapEnable  
  INTEGER as pktSwchEncapsulationMode  

PktSwchXidSEntry  
SEQUENCE    
  Integer32 as pktSwchXidIndexS  
  Integer32 as pktSwchXidInternalIndexS  
  DisplayString as pktSwchXidPasswdS  
  DisplayString as pktSwchXidPhoneS  
  INTEGER as pktSwchXidStatusS  

PktSwchXidAEntry  
SEQUENCE    
  Integer32 as pktSwchXidIndexA  
  Integer32 as pktSwchXidInternalIndexA  
  DisplayString as pktSwchXidPasswdA  
  DisplayString as pktSwchXidPhoneA  
  INTEGER as pktSwchXidStatusA  

PktSwchIpRoutSEntry  
SEQUENCE    
  Integer32 as pktSwchIpRoutIdS  
  IpAddress as pktSwchIpRoutIpAddressS  
  IpAddress as pktSwchIpRoutIpMaskS  
  INTEGER as pktSwchIpRoutDestProtocolS  
  DisplayString as pktSwchIpRoutDestinationS  
  Integer32 as pktSwchIpRoutInactivityS  
  INTEGER as pktSwchIpRoutStatusS  
  Integer32 as pktSwchIpRoutMetricS  
  IpAddress as pktSwchIpRoutNextHopS  
  Integer32 as pktSwchIpRoutInterfaceIdS  

PktSwchIpRoutAEntry  
SEQUENCE    
  Integer32 as pktSwchIpRoutIdA  
  IpAddress as pktSwchIpRoutIpAddressA  
  IpAddress as pktSwchIpRoutIpMaskA  
  INTEGER as pktSwchIpRoutDestProtocolA  
  DisplayString as pktSwchIpRoutDestinationA  
  Integer32 as pktSwchIpRoutInactivityA  
  Counter32 as pktSwchIpRoutBuffsInA  
  Counter32 as pktSwchIpRoutBuffsOutA  
  INTEGER as pktSwchIpRoutFCA  
  Integer32 as pktSwchIpRoutMetricA  
  IpAddress as pktSwchIpRoutNextHopA  
  Integer32 as pktSwchIpRoutInterfaceIdA  

PktSwchTxPriorityEntry  
SEQUENCE    
  Integer32 as pktSwchTxPriorityLevel  
  Integer32 as pktSwchTxPriorityMaxDelayTime  
  Integer32 as pktSwchTxPriorityMaxQueueLen  

PktSwchProfileSEntry  
SEQUENCE    
  Integer32 as pktSwchProfileNumberS  
  Integer32 as pktSwchProfileRecallCharS  
  INTEGER as pktSwchProfileEchoS  
  Integer32 as pktSwchProfileDataForwCharS  
  Integer32 as pktSwchProfileIdleTimerS  
  INTEGER as pktSwchProfileDevFlowContS  
  INTEGER as pktSwchProfileServSigS  
  Integer32 as pktSwchProfileBreakS  
  INTEGER as pktSwchProfileDiscOutS  
  Integer32 as pktSwchProfileCRPaddingS  
  Integer32 as pktSwchProfileLineFoldS  
  INTEGER as pktSwchProfileSpeedS  
  INTEGER as pktSwchProfilePadFlowContS  
  INTEGER as pktSwchProfileLineFeedInsertS  
  Integer32 as pktSwchProfileLineFeedPadS  
  INTEGER as pktSwchProfileEditingS  
  Integer32 as pktSwchProfileCharDelS  
  Integer32 as pktSwchProfileLineDelS  
  Integer32 as pktSwchProfileLineDispS  
  Integer32 as pktSwchProfileEditServSigS  
  Integer32 as pktSwchProfileEchomaskS  
  INTEGER as pktSwchProfileParTreatS  
  Integer32 as pktSwchProfilePageWaitS  
  Integer32 as pktSwchProfileBitsPerCharS  
  INTEGER as pktSwchProfileDvParityS  
  INTEGER as pktSwchProfileStopBitsS  
  INTEGER as pktSwchProfileSpecFlowS  
  Integer32 as pktSwchProfileCountFwdS  
  Integer32 as pktSwchProfileEscDelayS  
  Integer32 as pktSwchProfileCharBreakS  
  Integer32 as pktSwchProfileCharSuppressS  
  Integer32 as pktSwchProfileCharSubsS  
  Integer32 as pktSwchProfileFormFeedPadS  
  Integer32 as pktSwchProfileInactivityS  
  Integer32 as pktSwchProfileOptionsS  
  Integer32 as pktSwchProfileClrTimerS  
  Integer32 as pktSwchProfileSubAddInCUDS  
  INTEGER as pktSwchProfileStatusS  

PktSwchProfileAEntry  
SEQUENCE    
  Integer32 as pktSwchProfileNumberA  
  Integer32 as pktSwchProfileRecallCharA  
  INTEGER as pktSwchProfileEchoA  
  Integer32 as pktSwchProfileDataForwCharA  
  Integer32 as pktSwchProfileIdleTimerA  
  INTEGER as pktSwchProfileDevFlowContA  
  INTEGER as pktSwchProfileServSigA  
  Integer32 as pktSwchProfileBreakA  
  INTEGER as pktSwchProfileDiscOutA  
  Integer32 as pktSwchProfileCRPaddingA  
  Integer32 as pktSwchProfileLineFoldA  
  INTEGER as pktSwchProfileSpeedA  
  INTEGER as pktSwchProfilePadFlowContA  
  INTEGER as pktSwchProfileLineFeedInsertA  
  Integer32 as pktSwchProfileLineFeedPadA  
  INTEGER as pktSwchProfileEditingA  
  Integer32 as pktSwchProfileCharDelA  
  Integer32 as pktSwchProfileLineDelA  
  Integer32 as pktSwchProfileLineDispA  
  Integer32 as pktSwchProfileEditServSigA  
  Integer32 as pktSwchProfileEchomaskA  
  INTEGER as pktSwchProfileParTreatA  
  Integer32 as pktSwchProfilePageWaitA  
  Integer32 as pktSwchProfileBitsPerCharA  
  INTEGER as pktSwchProfileDvParityA  
  INTEGER as pktSwchProfileStopBitsA  
  INTEGER as pktSwchProfileSpecFlowA  
  Integer32 as pktSwchProfileCountFwdA  
  Integer32 as pktSwchProfileEscDelayA  
  Integer32 as pktSwchProfileCharBreakA  
  Integer32 as pktSwchProfileCharSuppressA  
  Integer32 as pktSwchProfileCharSubsA  
  Integer32 as pktSwchProfileFormFeedPadA  
  Integer32 as pktSwchProfileInactivityA  
  Integer32 as pktSwchProfileOptionsA  
  Integer32 as pktSwchProfileClrTimerA  
  Integer32 as pktSwchProfileSubAddInCUDA  

PktSwchChannelSEntry  
SEQUENCE    
  Integer32 as pktSwchChannelIfIndexS  
  Integer32 as pktSwchChannelNumberS  
  Integer32 as pktSwchChannelProfileS  
  Integer32 as pktSwchChannelOutCallProfileS  
  Integer32 as pktSwchChannelInCallProfileS  
  Integer32 as pktSwchChannelRemoteProfileS  
  Integer32 as pktSwchChannelAutocallIdS  
  Integer32 as pktSwchChannelAlterAutocallIdS  
  Integer32 as pktSwchChannelAutocallRetriesS  
  Integer32 as pktSwchChannelAutocallIntervalS  
  Integer32 as pktSwchChannelCallAliasS  
  Integer32 as pktSwchChannelSubAddress1S  
  Integer32 as pktSwchChannelSubAddress2S  
  Integer32 as pktSwchChannelNUISEntry  
  Integer32 as pktSwchChannelClearTimerS  
  Integer32 as pktSwchChannelOptionsS  
  INTEGER as pktSwchChannelClear  
  Integer32 as pktSwchChannelCopyTo  
  Integer32 as pktSwchChannelCopyToWMask  
  Integer32 as pktSwchChannelCopyMask  

PktSwchChannelAEntry  
SEQUENCE    
  Integer32 as pktSwchChannelIfIndexA  
  Integer32 as pktSwchChannelNumberA  
  Integer32 as pktSwchChannelProfileA  
  Integer32 as pktSwchChannelOutCallProfileA  
  Integer32 as pktSwchChannelInCallProfileA  
  Integer32 as pktSwchChannelRemoteProfileA  
  Integer32 as pktSwchChannelAutocallIdA  
  Integer32 as pktSwchChannelAlterAutocallIdA  
  Integer32 as pktSwchChannelAutocallRetriesA  
  Integer32 as pktSwchChannelAutocallIntervalA  
  Integer32 as pktSwchChannelCallAliasA  
  Integer32 as pktSwchChannelSubAddress1A  
  Integer32 as pktSwchChannelSubAddress2A  
  Integer32 as pktSwchChannelNUIAEntry  
  Integer32 as pktSwchChannelClearTimerA  
  Integer32 as pktSwchChannelOptionsA  

PktSwchCallIdSEntry  
SEQUENCE    
  Integer32 as pktSwchCallIdNumberS  
  DisplayString as pktSwchCallIdMnemonicS  
  DisplayString as pktSwchCallIdAddressS  
  INTEGER as pktSwchCallIdStatusS  

PktSwchCallIdAEntry  
SEQUENCE    
  Integer32 as pktSwchCallIdNumberA  
  DisplayString as pktSwchCallIdMnemonicA  
  DisplayString as pktSwchCallIdAddressA  

PktSwchAliasSEntry  
SEQUENCE    
  Integer32 as pktSwchAliasNumberS  
  DisplayString as pktSwchAliasValueS  
  INTEGER as pktSwchAliasStatusS  

PktSwchAliasAEntry  
SEQUENCE    
  Integer32 as pktSwchAliasNumberA  
  DisplayString as pktSwchAliasValueA  

PktSwchAsyncStatEntry  
SEQUENCE    
  Integer32 as pktSwchAsyncIfIndex  
  Integer32 as pktSwchAsyncChannelNumber  
  INTEGER as pktSwchAsyncConnectionStatus  
  Integer32 as pktSwchAsyncNumLogChannels  
  Integer32 as pktSwchAsyncNumActSessions  
  Integer32 as pktSwchAsyncAutocallId  
  INTEGER as pktSwchAsyncRTSStatus  
  Integer32 as pktSwchAsyncBuffToNet  
  Integer32 as pktSwchAsyncBuffToUser  
  INTEGER as pktSwchAsyncTxXoff  
  INTEGER as pktSwchAsyncRxXoff  
  Integer32 as pktSwchAsyncBuffOutstand  
  INTEGER as pktSwchAsyncChannelMode  

PktSwchAsyncRunProEntry  
SEQUENCE    
  Integer32 as pktSwchAsyncRunProIfIndex  
  Integer32 as pktSwchAsyncRunProChannelNumber  
  Integer32 as pktSwchAsyncRunProRecallChar  
  INTEGER as pktSwchAsyncRunProEcho  
  Integer32 as pktSwchAsyncRunProDataForwChar  
  Integer32 as pktSwchAsyncRunProIdleTimer  
  INTEGER as pktSwchAsyncRunProDevFlowCont  
  INTEGER as pktSwchAsyncRunProServSig  
  Integer32 as pktSwchAsyncRunProBreak  
  INTEGER as pktSwchAsyncRunProDiscOut  
  Integer32 as pktSwchAsyncRunProCRPPadding  
  Integer32 as pktSwchAsyncRunProLineFold  
  INTEGER as pktSwchAsyncRunProSpeed  
  INTEGER as pktSwchAsyncRunProPadFlowCont  
  INTEGER as pktSwchAsyncRunProLineFeedInsert  
  Integer32 as pktSwchAsyncRunProLineFeedPad  
  INTEGER as pktSwchAsyncRunProEditing  
  Integer32 as pktSwchAsyncRunProCharDel  
  Integer32 as pktSwchAsyncRunProLineDel  
  Integer32 as pktSwchAsyncRunProLineDisp  
  Integer32 as pktSwchAsyncRunProEditServSig  
  Integer32 as pktSwchAsyncRunProEchomask  
  INTEGER as pktSwchAsyncRunProParTreat  
  Integer32 as pktSwchAsyncRunProPageWait  

PktSwchPhyInterfaceEntry  
SEQUENCE    
  Integer32 as pktSwchPhyInterfaceIfIndex  
  INTEGER as pktSwchPhyInterfaceProtocolS  
  INTEGER as pktSwchPhyInterfaceProtocolA  
  Integer32 as pktSwchPhyInterfaceCopyTo  
  INTEGER as pktSwchPhyInterfaceChanged  
  Integer32 as pktSwchPhyInterfaceRxBuffInPool  
  INTEGER as pktSwchPhyInterfaceConnector  
  IpAddress as pktSwchPhyInterfaceNeighborIp  
  INTEGER as pktSwchPhyInterfaceProtocolStatus  
  INTEGER as pktSwchPhyInterfaceTestCmd  
  Counter32 as pktSwchPhyInterfaceTestTransmittedFrames  
  Counter32 as pktSwchPhyInterfaceTestReceivedFrames  
  Integer32 as pktSwchPhyInterfaceTestLostFrames  

PktSwchLapbSEntry  
SEQUENCE    
  Integer32 as pktSwchLapbLinkNumberS  
  INTEGER as pktSwchLapbInternalClockS  
  Integer32 as pktSwchLapbLineOptionS  
  Integer32 as pktSwchLapbSegmentSizeS  
  Integer32 as pktSwchLapbXIDS  
  Integer32 as pktSwchLapbAckCounterS  
  Integer32 as pktSwchLapbAckTimerS  

PktSwchLapbAEntry  
SEQUENCE    
  Integer32 as pktSwchLapbLinkNumberA  
  INTEGER as pktSwchLapbInternalClockA  
  Integer32 as pktSwchLapbLineOptionA  
  Integer32 as pktSwchLapbSegmentSizeA  
  INTEGER as pktSwchLapbLineProtocol  
  Integer32 as pktSwchLapbLowerId  
  Integer32 as pktSwchLapbXIDA  
  Counter32 as pktSwchLapbTransmittedIFrames  
  Counter32 as pktSwchLapbReceivedIFrames  
  Counter32 as pktSwchLapbNSError  
  Counter32 as pktSwchLapbTransmittedRRFrames  
  Counter32 as pktSwchLapbReceivedRRFrames  
  Counter32 as pktSwchLapbTransmittedRNRFrames  
  Counter32 as pktSwchLapbReceivedRNRFrames  
  Counter32 as pktSwchLapbTransmittedFRMRFrames  
  Counter32 as pktSwchLapbReceivedFRMRFrames  
  Integer32 as pktSwchLapbAckCounterA  
  Integer32 as pktSwchLapbAckTimerA  

PktSwchPlpSEntry  
SEQUENCE    
  Integer32 as pktSwchPlpLinkNumberS  
  Integer32 as pktSwchPlpInCallOptionS  
  Integer32 as pktSwchPlpOutCallOptionS  
  INTEGER as pktSwchPlpCugSubscriptionS  
  Integer32 as pktSwchPlpNUIS  
  Integer32 as pktSwchPlpCpyPktSize  
  Integer32 as pktSwchPlpCpyWinSize  

PktSwchPlpAEntry  
SEQUENCE    
  Integer32 as pktSwchPlpLinkNumberA  
  Integer32 as pktSwchPlpInCallOptionA  
  Integer32 as pktSwchPlpOutCallOptionA  
  INTEGER as pktSwchPlpCugSubscriptionA  
  Integer32 as pktSwchPlpNUIA  
  Counter32 as pktSwchStatOutRestarts  

PktSwchCugSEntry  
SEQUENCE    
  Integer32 as pktSwchCugLinkNumberS  
  Integer32 as pktSwchCugIndexS  
  Integer32 as pktSwchCugNumberS  
  INTEGER as pktSwchCugStatus  

PktSwchCugAEntry  
SEQUENCE    
  Integer32 as pktSwchCugLinkNumberA  
  Integer32 as pktSwchCugIndexA  
  Integer32 as pktSwchCugNumberA  

PktSwchLogChAssEntry  
SEQUENCE    
  IfIndexType as pktSwchLogChAssIndex  
  Integer32 as pktSwchLogChAssLIC  
  Integer32 as pktSwchLogChAssHIC  
  Integer32 as pktSwchLogChAssLTC  
  Integer32 as pktSwchLogChAssHTC  
  Integer32 as pktSwchLogChAssLOC  
  Integer32 as pktSwchLogChAssHOC  

PktSwchLogChPartnerEntry  
SEQUENCE    
  IfIndexType as pktSwchLogChPartnerIfIndex  
  Integer32 as pktSwchLogChPartnerLcIndex  
  INTEGER as pktSwchLogChPartnerProtocol  
  IfIndexType as pktSwchLogChPartnerOpIfIndex  
  Integer32 as pktSwchLogChPartnerOpLcIndex  

PktSwchHdlcSEntry  
SEQUENCE    
  Integer32 as pktSwchHdlcLinkNumberS  
  DisplayString as pktSwchHdlcDestAddrS  
  Integer32 as pktSwchHdlcDestSubAddrS  
  Integer32 as pktSwchHdlcRedialTimeoutS  
  Integer32 as pktSwchHdlcRedialRetriesS  
  Integer32 as pktSwchHdlcInactivityS  
  Integer32 as pktSwchHdlcX25FacilitiesS  
  Integer32 as pktSwchHdlcLocalSubaddr1S  
  Integer32 as pktSwchHdlcLocalSubaddr2S  
  Integer32 as pktSwchHdlcDestDlciS  
  Integer32 as pktSwchHdlcDestPortS  
  INTEGER as pktSwchHdlcProtocolS  
  Integer32 as pktSwchHdlcFlowContOptionsS  
  Integer32 as pktSwchHdlcBufferFlowControlS  
  INTEGER as pktSwchHdlcInternalClockS  
  Integer32 as pktSwchHdlcNrzModeS  

PktSwchHdlcAEntry  
SEQUENCE    
  Integer32 as pktSwchHdlcLinkNumberA  
  DisplayString as pktSwchHdlcDestAddrA  
  Integer32 as pktSwchHdlcDestSubAddrA  
  Integer32 as pktSwchHdlcRedialTimeoutA  
  Integer32 as pktSwchHdlcRedialRetriesA  
  Integer32 as pktSwchHdlcInactivityA  
  Integer32 as pktSwchHdlcX25FacilitiesA  
  Integer32 as pktSwchHdlcLocalSubaddr1A  
  Integer32 as pktSwchHdlcLocalSubaddr2A  
  Integer32 as pktSwchHdlcDestDlciA  
  Integer32 as pktSwchHdlcDestPortA  
  INTEGER as pktSwchHdlcProtocolA  
  Integer32 as pktSwchHdlcFlowContOptionsA  
  Integer32 as pktSwchHdlcBufferFlowControlA  
  INTEGER as pktSwchHdlcInternalClockA  
  Integer32 as pktSwchHdlcNrzModeA  
  INTEGER as pktSwchHdlcConnStatus  
  INTEGER as pktSwchHdlcSpecialStatus  
  INTEGER as pktSwchHdlcCtsStatus  
  DisplayString as pktSwchHdlcRunningX25Lcn  
  DisplayString as pktSwchHdlcRunningDlci  
  Integer32 as pktSwchHdlcMaxBuffToNet  
  Integer32 as pktSwchHdlcBuffToNet  

PktSwchStmEntry  
SEQUENCE    
  Integer32 as pktSwchStmLinkNumber  
  INTEGER as pktSwchStmInternalClockS  
  INTEGER as pktSwchStmInternalClockA  
  INTEGER as pktSwchStmConn  
  Counter32 as pktSwchStmSyncLoss  

PktSwchFrSEntry  
SEQUENCE    
  Integer32 as pktSwchFrIfIndexS  
  Integer32 as pktSwchFrMaintProtS  
  INTEGER as pktSwchFrMaintModeS  
  Integer32 as pktSwchFrRxPoolRedLineS  
  Integer32 as pktSwchFrRxPoolOkS  
  Integer32 as pktSwchFrTxPoolRedLineS  
  Integer32 as pktSwchFrTxPoolOkS  
  Integer32 as pktSwchFrTxCeilingS  
  INTEGER as pktSwchFrInternalClockS  
  INTEGER as pktSwchFrNrzModeS  
  INTEGER as pktSwchFrDlciHeaderModeS  
  INTEGER as pktSwchFrDcdLinkFailureS  
  INTEGER as pktSwchFrTxIdlesS  
  INTEGER as pktSwchFrOperationModeS  
  INTEGER as pktSwchFrPhysInterfOptionsS  

PktSwchFrAEntry  
SEQUENCE    
  Integer32 as pktSwchFrIfIndexA  
  Integer32 as pktSwchFrMaintProtA  
  INTEGER as pktSwchFrMaintModeA  
  Integer32 as pktSwchFrRxPoolRedLineA  
  Integer32 as pktSwchFrRxPoolOkA  
  Integer32 as pktSwchFrTxPoolRedLineA  
  Integer32 as pktSwchFrTxPoolOkA  
  Integer32 as pktSwchFrTxCeilingA  
  INTEGER as pktSwchFrInternalClockA  
  INTEGER as pktSwchFrNrzModeA  
  Integer32 as pktSwchFrDlcmiPollingInterval  
  Integer32 as pktSwchFrDlcmiFullEnquiryInterval  
  Integer32 as pktSwchFrDlcmiErrorThreshold  
  Integer32 as pktSwchFrDlcmiMonitoredEvents  
  INTEGER as pktSwchFrDlciHeaderModeA  
  INTEGER as pktSwchFrDcdLinkFailureA  
  INTEGER as pktSwchFrTxIdlesA  
  INTEGER as pktSwchFrOperationModeA  
  INTEGER as pktSwchFrPhysInterfOptionsA  

PktSwchFrIfEntry  
SEQUENCE    
  Counter32 as pktSwchFrIfTxBytes  
  Counter32 as pktSwchFrIfRxBytes  
  Counter32 as pktSwchFrIfTxCongDiscards  
  Counter32 as pktSwchFrIfDeTxFrames  
  Counter32 as pktSwchFrIfDeRxFrames  
  Counter32 as pktSwchFrIfFecnTxFrames  
  Counter32 as pktSwchFrIfFecnRxFrames  
  Counter32 as pktSwchFrIfBecnTxFrames  
  Counter32 as pktSwchFrIfBecnRxFrames  
  Counter32 as pktSwchFrIfCommRateViolTxFrames  
  Counter32 as pktSwchFrIfCommRateViolRxFrames  
  Counter32 as pktSwchFrIfExcessRateViolTxFrames  
  Counter32 as pktSwchFrIfExcessRateViolRxFrames  
  Integer32 as pktSwchFrIfBuffersInTxPool  
  Integer32 as pktSwchFrIfFreeBuffersInRxPool  
  Counter32 as pktSwchFrIfLmiTxFrames  
  Counter32 as pktSwchFrIfLmiRxFrames  
  Counter32 as pktSwchFrIfAnsiTxFrames  
  Counter32 as pktSwchFrIfAnsiRxFrames  
  Counter32 as pktSwchFrIfCllmTxFrames  
  Counter32 as pktSwchFrIfCllmRxFrames  
  Counter32 as pktSwchFrIfTxCongestions  
  Counter32 as pktSwchFrIfRxCongestions  
  Integer32 as pktSwchFrIfTotDlciNumber  

PktSwchFrCircuitSEntry  
SEQUENCE    
  Integer32 as pktSwchFrCircuitIfIndexS  
  Integer32 as pktSwchFrCircuitIndexS  
  INTEGER as pktSwchFrCircuitDestProtS  
  DisplayString as pktSwchFrCircuitDestIdS  
  DisplayString as pktSwchFrCircuitBackIdS  
  Integer32 as pktSwchFrCircuitTxCirIntervalS  
  Integer32 as pktSwchFrCircuitTxCommittedS  
  Integer32 as pktSwchFrCircuitTxExcessS  
  Integer32 as pktSwchFrCircuitRxCirIntervalS  
  Integer32 as pktSwchFrCircuitRxCommittedS  
  Integer32 as pktSwchFrCircuitRxExcessS  
  Integer32 as pktSwchFrCircuitFunnelIdS  
  INTEGER as pktSwchFrCircuitStatusS  
  Integer32 as pktSwchFrCircuitExtendedDlciS  
  Integer32 as pktSwchFrCircuitTxPriorityS  
  Integer32 as pktSwchFrCircuitIsdnRoutIdS  

PktSwchFrCircuitAEntry  
SEQUENCE    
  Integer32 as pktSwchFrCircuitIfIndexA  
  Integer32 as pktSwchFrCircuitIndexA  
  INTEGER as pktSwchFrCircuitDestProtA  
  DisplayString as pktSwchFrCircuitDestIdA  
  DisplayString as pktSwchFrCircuitBackIdA  
  Integer32 as pktSwchFrCircuitTxCirIntervalA  
  Integer32 as pktSwchFrCircuitTxCommittedA  
  Integer32 as pktSwchFrCircuitTxExcessA  
  Integer32 as pktSwchFrCircuitRxCirIntervalA  
  Integer32 as pktSwchFrCircuitRxCommittedA  
  Integer32 as pktSwchFrCircuitRxExcessA  
  Integer32 as pktSwchFrCircuitFunnelIdA  
  DisplayString as pktSwchFrCircuitFunnelStat  
  Counter32 as pktSwchFrCircuitTxCongDiscards  
  Counter32 as pktSwchFrCircuitDeTxFrames  
  Counter32 as pktSwchFrCircuitDeRxFrames  
  Counter32 as pktSwchFrCircuitFecnTxFrames  
  Counter32 as pktSwchFrCircuitBecnTxFrames  
  Counter32 as pktSwchFrCircuitCommRateViolTxFrames  
  Counter32 as pktSwchFrCircuitCommRateViolRxFrames  
  Counter32 as pktSwchFrCircuitExcessRateViolTxFrames  
  Counter32 as pktSwchFrCircuitExcessRateViolRxFrames  
  INTEGER as pktSwchFrCircuitState  
  Integer32 as pktSwchFrCircuitExtendedDlciA  
  Integer32 as pktSwchFrCircuitTxPriorityA  
  Integer32 as pktSwchFrCircuitIsdnRoutIdA  

PktSwchFrFunnelSEntry  
SEQUENCE    
  Integer32 as pktSwchFrFunnelIndexS  
  Integer32 as pktSwchFrFunnelSizeS  
  Integer32 as pktSwchFrFunnelHighWaterFramesS  
  Integer32 as pktSwchFrFunnelHighWaterBytesS  
  Integer32 as pktSwchFrFunnelGaugeTxRateS  
  Integer32 as pktSwchFrFunnelTransWindowS  
  INTEGER as pktSwchFrFunnelStatusS  

PktSwchFrFunnelAEntry  
SEQUENCE    
  Integer32 as pktSwchFrFunnelIndexA  
  Integer32 as pktSwchFrFunnelSizeA  
  Integer32 as pktSwchFrFunnelHighWaterFramesA  
  Integer32 as pktSwchFrFunnelHighWaterBytesA  
  Integer32 as pktSwchFrFunnelGaugeTxRateA  
  Integer32 as pktSwchFrFunnelTransWindowA  

PktSwchFrDlciMapEntry  
SEQUENCE    
  Integer32 as pktSwchFrDlciMapPort  
  Integer32 as pktSwchFrDlciMapLongDlci  
  Integer32 as pktSwchFrDlciMapShortDlci  
  INTEGER as pktSwchFrDlciMapStatus  

PktSwchMpeSEntry  
SEQUENCE    
  Integer32 as pktSwchMpeLinkNumberS  
  Integer32 as pktSwchMpeInactivityS  
  Integer32 as pktSwchMpeX25FacilitiesS  
  Integer32 as pktSwchMpeLocSubAddr1S  
  Integer32 as pktSwchMpeLocSubAddr2S  
  Integer32 as pktSwchMpeFlwCtrlDurS  
  Integer32 as pktSwchMpeFlwCtrlOptS  
  Integer32 as pktSwchMpeFlwCtrlBufS  
  INTEGER as pktSwchMpeInternalClkS  

PktSwchMpeAEntry  
SEQUENCE    
  Integer32 as pktSwchMpeLinkNumberA  
  Integer32 as pktSwchMpeInactivityA  
  Integer32 as pktSwchMpeX25FacilitiesA  
  Integer32 as pktSwchMpeLocSubAddr1A  
  Integer32 as pktSwchMpeLocSubAddr2A  
  Integer32 as pktSwchMpeFlwCtrlDurA  
  Integer32 as pktSwchMpeFlwCtrlOptA  
  Integer32 as pktSwchMpeFlwCtrlBufA  
  INTEGER as pktSwchMpeInternalClkA  
  INTEGER as pktSwchMpeCtsStatus  

PktSwchMpeAidSEntry  
SEQUENCE    
  Integer32 as pktSwchMpeAddressIdS  
  INTEGER as pktSwchMpeAidMainTypeS  
  Integer32 as pktSwchMpeAidMainIdS  
  Integer32 as pktSwchMpeAidMainSubIdS  
  INTEGER as pktSwchMpeAidBackupTypeS  
  Integer32 as pktSwchMpeAidBackupIdS  
  Integer32 as pktSwchMpeAidBackupSubIdS  
  INTEGER as pktSwchMpeAidStatusS  

PktSwchMpeAidAEntry  
SEQUENCE    
  Integer32 as pktSwchMpeAddressIdA  
  INTEGER as pktSwchMpeAidMainTypeA  
  Integer32 as pktSwchMpeAidMainIdA  
  Integer32 as pktSwchMpeAidMainSubIdA  
  INTEGER as pktSwchMpeAidBackupTypeA  
  Integer32 as pktSwchMpeAidBackupIdA  
  Integer32 as pktSwchMpeAidBackupSubIdA  
  INTEGER as pktSwchMpeAidConn  
  INTEGER as pktSwchMpeAidFlwCtrl  

PktSwchSlipSEntry  
SEQUENCE    
  Integer32 as pktSwchSlipLinkNumberS  
  INTEGER as pktSwchSlipSpeedS  
  Integer32 as pktSwchSlipFCOptionS  
  INTEGER as pktSwchSlipStopBitsS  
  Integer32 as pktSwchSlipBitPerCharS  
  INTEGER as pktSwchSlipParityS  
  IpAddress as pktSwchSlipIpAddressS  
  IpAddress as pktSwchSlipIpMaskS  
  INTEGER as pktSwchSlipDefEncapsTypeS  
  DisplayString as pktSwchSlipDefDestinationS  

PktSwchSlipAEntry  
SEQUENCE    
  Integer32 as pktSwchSlipLinkNumberA  
  INTEGER as pktSwchSlipSpeedA  
  Integer32 as pktSwchSlipFCOptionA  
  INTEGER as pktSwchSlipStopBitsA  
  Integer32 as pktSwchSlipBitPerCharA  
  INTEGER as pktSwchSlipParityA  
  IpAddress as pktSwchSlipIpAddressA  
  IpAddress as pktSwchSlipIpMaskA  
  INTEGER as pktSwchSlipDefEncapsTypeA  
  DisplayString as pktSwchSlipDefDestinationA  

PktSwchSnaSDLCLinkEntryS  
SEQUENCE    
  INTEGER as pktSwchSnaSDLCLinkTypeS  
  INTEGER as pktSwchSnaSDLCLinkPUSharedS  
  INTEGER as pktSwchSnaSDLCLinkDuplexPhyS  
  Integer32 as pktSwchSnaSDLCLinkflagsS  
  INTEGER as pktSwchSnaSDLCLinkDuplexS  
  INTEGER as pktSwchSnaSDLCLinkClockS  
  INTEGER as pktSwchSnaSDLCLinkNRZS  

PktSwchSnaSDLCLinkEntryA  
SEQUENCE    
  INTEGER as pktSwchSnaSDLCLinkTypeA  
  INTEGER as pktSwchSnaSDLCLinkPUSharedA  
  INTEGER as pktSwchSnaSDLCLinkDuplexPhyA  
  Integer32 as pktSwchSnaSDLCLinkflagsA  
  INTEGER as pktSwchSnaSDLCLinkDuplexA  
  INTEGER as pktSwchSnaSDLCLinkClockA  
  INTEGER as pktSwchSnaSDLCLinkNRZA  
  Counter32 as pktSwchSnaSDLCLinkStatFrames  
  Counter32 as pktSwchSnaSDLCLinkStatErrors  
  Counter32 as pktSwchSnaSDLCLinkStatInvalidAddresses  
  Counter32 as pktSwchSnaSDLCLinkStatShortFrames  

PktSwchSnaPUEntryS  
SEQUENCE    
  Integer32 as pktSwchSnaPUNumberS  
  INTEGER as pktSwchSnaPUXIDProcessingS  
  INTEGER as pktSwchSnaPUEnableS  
  INTEGER as pktSwchSnaPULinkATypeS  
  INTEGER as pktSwchSnaPULinkARoleS  
  INTEGER as pktSwchSnaPULinkBTypeS  
  INTEGER as pktSwchSnaPULinkBRoleS  
  INTEGER as pktSwchSnaPUEntryStatusS  

PktSwchSnaPUEntryA  
SEQUENCE    
  Integer32 as pktSwchSnaPUNumberA  
  INTEGER as pktSwchSnaPUXIDProcessingA  
  INTEGER as pktSwchSnaPUEnableA  
  INTEGER as pktSwchSnaPULinkATypeA  
  INTEGER as pktSwchSnaPULinkARoleA  
  INTEGER as pktSwchSnaPULinkBTypeA  
  INTEGER as pktSwchSnaPULinkBRoleA  

PktSwchSnaPUSdlcEntryS  
SEQUENCE    
  Integer32 as pktSwchSnaPUSdlcNumberS  
  INTEGER as pktSwchSnaPUSdlcSideS  
  OCTET STRING as pktSwchSnaPUSdlcAddressS  
  Integer32 as pktSwchSnaPUSdlcIfIndexS  
  OCTET STRING as pktSwchSnaPUSdlcIdBlkS  
  OCTET STRING as pktSwchSnaPUSdlcIdNumS  
  Integer32 as pktSwchSnaPUSdlcMaxPiuSizeS  
  Integer32 as pktSwchSnaPUSdlcTxWindowS  
  OCTET STRING as pktSwchSnaPUSdlcGrpAddressS  
  Integer32 as pktSwchSnaPUSdlcPollTimerS  
  INTEGER as pktSwchSnaPUSdlcXIDInitiationS  
  INTEGER as pktSwchSnaPUSdlcEntryStatusS  

PktSwchSnaPUSdlcEntryA  
SEQUENCE    
  Integer32 as pktSwchSnaPUSdlcNumberA  
  INTEGER as pktSwchSnaPUSdlcSideA  
  OCTET STRING as pktSwchSnaPUSdlcAddressA  
  Integer32 as pktSwchSnaPUSdlcIfIndexA  
  OCTET STRING as pktSwchSnaPUSdlcIdBlkA  
  OCTET STRING as pktSwchSnaPUSdlcIdNumA  
  Integer32 as pktSwchSnaPUSdlcMaxPiuSizeA  
  Integer32 as pktSwchSnaPUSdlcTxWindowA  
  OCTET STRING as pktSwchSnaPUSdlcGrpAddressA  
  Integer32 as pktSwchSnaPUSdlcPollTimerA  
  INTEGER as pktSwchSnaPUSdlcXIDInitiationA  

PktSwchSnaPUSdlcStatEntry  
SEQUENCE    
  Integer32 as pktSwchSnaPUSdlcStatNumber  
  INTEGER as pktSwchSnaPUSdlcStatSide  
  Counter32 as pktSwchSnaPUSdlcStatOctetsIn  
  Counter32 as pktSwchSnaPUSdlcStatOctetsOut  
  Counter32 as pktSwchSnaPUSdlcStatIFramesIn  
  Counter32 as pktSwchSnaPUSdlcStatIFramesOut  
  Counter32 as pktSwchSnaPUSdlcStatRRFramesIn  
  Counter32 as pktSwchSnaPUSdlcStatRRFramesOut  
  Counter32 as pktSwchSnaPUSdlcStatRNRFramesIn  
  Counter32 as pktSwchSnaPUSdlcStatRNRFramesOut  
  Counter32 as pktSwchSnaPUSdlcStatXIDsIn  
  Counter32 as pktSwchSnaPUSdlcStatXIDsOut  
  Counter32 as pktSwchSnaPUSdlcStatTESTsIn  
  Counter32 as pktSwchSnaPUSdlcStatTESTsOut  
  Counter32 as pktSwchSnaPUSdlcStatREJsIn  
  Counter32 as pktSwchSnaPUSdlcStatREJsOut  
  Counter32 as pktSwchSnaPUSdlcStatFRMRsIn  
  Counter32 as pktSwchSnaPUSdlcStatFRMRsOut  
  Counter32 as pktSwchSnaPUSdlcStatDISCsIn  
  Counter32 as pktSwchSnaPUSdlcStatDISCsOut  
  Counter32 as pktSwchSnaPUSdlcStatUAsIn  
  Counter32 as pktSwchSnaPUSdlcStatUAsOut  
  Counter32 as pktSwchSnaPUSdlcStatDMsIn  
  Counter32 as pktSwchSnaPUSdlcStatDMsOut  
  Counter32 as pktSwchSnaPUSdlcStatSNRMsIn  
  Counter32 as pktSwchSnaPUSdlcStatSNRMsOut  
  Counter32 as pktSwchSnaPUSdlcStatRetransmitsIn  
  Counter32 as pktSwchSnaPUSdlcStatRetransmitsOut  
  INTEGER as pktSwchSnaPUSdlcUpperState  
  INTEGER as pktSwchSnaPUSdlcLowerState  
  INTEGER as pktSwchSnaPUSdlcStatNRMStatus  
  INTEGER as pktSwchSnaPUSdlcStatFlowCtlStatus  

PktSwchSnaPUX25QllcEntryS  
SEQUENCE    
  Integer32 as pktSwchSnaPUX25QllcNumberS  
  INTEGER as pktSwchSnaPUX25QllcSideS  
  OCTET STRING as pktSwchSnaPUX25QllcIdBlkS  
  OCTET STRING as pktSwchSnaPUX25QllcIdNumS  
  INTEGER as pktSwchSnaPUX25QllcXIDInitS  
  Integer32 as pktSwchSnaPUX25QllcMaxPiuSizeS  
  OCTET STRING as pktSwchSnaPUX25QllcStationAddressS  
  DisplayString as pktSwchSnaPUX25QllcInPasswordS  
  Integer32 as pktSwchSnaPUX25QllcSubAddressS  
  INTEGER as pktSwchSnaPUX25QllcAutoCallS  
  OCTET STRING as pktSwchSnaPUX25QllcCalledAddressS  
  DisplayString as pktSwchSnaPUX25QllcCallUserDataFacilitiesS  
  INTEGER as pktSwchSnaPUX25QllcEntryStatusS  

PktSwchSnaPUX25QllcEntryA  
SEQUENCE    
  Integer32 as pktSwchSnaPUX25QllcNumberA  
  INTEGER as pktSwchSnaPUX25QllcSideA  
  OCTET STRING as pktSwchSnaPUX25QllcIdBlkA  
  OCTET STRING as pktSwchSnaPUX25QllcIdNumA  
  INTEGER as pktSwchSnaPUX25QllcXIDInitA  
  Integer32 as pktSwchSnaPUX25QllcMaxPiuSizeA  
  OCTET STRING as pktSwchSnaPUX25QllcStationAddressA  
  DisplayString as pktSwchSnaPUX25QllcInPasswordA  
  Integer32 as pktSwchSnaPUX25QllcSubAddressA  
  INTEGER as pktSwchSnaPUX25QllcAutoCallA  
  OCTET STRING as pktSwchSnaPUX25QllcCalledAddressA  
  DisplayString as pktSwchSnaPUX25QllcCallUserDataFacilitiesA  

PktSwchSnaPUX25QllcStatEntry  
SEQUENCE    
  Integer32 as pktSwchSnaPUX25QllcStatNumber  
  INTEGER as pktSwchSnaPUX25QllcStatSide  
  Integer32 as pktSwchSnaPUX25QllcStatlink  
  Counter32 as pktSwchSnaPUX25QllcStatDataPacketsIn  
  Counter32 as pktSwchSnaPUX25QllcStatDataPacketsOut  
  Counter32 as pktSwchSnaPUX25QllcStatQSMPacketsIn  
  Counter32 as pktSwchSnaPUX25QllcStatQSMPacketsOut  
  Counter32 as pktSwchSnaPUX25QllcStatQDMPacketsIn  
  Counter32 as pktSwchSnaPUX25QllcStatQDMPacketsOut  
  Counter32 as pktSwchSnaPUX25QllcStatXIDPacketsIn  
  Counter32 as pktSwchSnaPUX25QllcStatXIDPacketsOut  
  Counter32 as pktSwchSnaPUX25QllcStatQDISCPacketsIn  
  Counter32 as pktSwchSnaPUX25QllcStatQDISCPacketsOut  
  Counter32 as pktSwchSnaPUX25QllcStatCallPacketsIn  
  Counter32 as pktSwchSnaPUX25QllcStatCallPacketsOut  
  Counter32 as pktSwchSnaPUX25QllcStatClearPacketsIn  
  Counter32 as pktSwchSnaPUX25QllcStatClearPacketsOut  
  Counter32 as pktSwchSnaPUX25QllcStatCallAcceptsIn  
  Counter32 as pktSwchSnaPUX25QllcStatCallAcceptsOut  
  INTEGER as pktSwchSnaPUX25QllcStatUpperState  
  INTEGER as pktSwchSnaPUX25QllcStatLowerState  
  INTEGER as pktSwchSnaPUX25QllcStatNRMStatus  
  INTEGER as pktSwchSnaPUX25QllcStatFlowCtlStatus  

PktSwchSnaPULlc2FrEntryS  
SEQUENCE    
  Integer32 as pktSwchSnaPULlc2FrNumberS  
  INTEGER as pktSwchSnaPULlc2FrSideS  
  INTEGER as pktSwchSnaPULlc2FrEncapsTypeS  
  OCTET STRING as pktSwchSnaPULlc2FrDestMACS  
  OCTET STRING as pktSwchSnaPULlc2FrSrcSAPS  
  OCTET STRING as pktSwchSnaPULlc2FrDestSAPS  
  OCTET STRING as pktSwchSnaPULlc2FrXIDIdBlkS  
  OCTET STRING as pktSwchSnaPULlc2FrXIDIdNumS  
  Integer32 as pktSwchSnaPULlc2FrMaxPiuSizeS  
  Integer32 as pktSwchSnaPULlc2FrTxWindowS  
  Integer32 as pktSwchSnaPULlc2FrLinkS  
  Integer32 as pktSwchSnaPULlc2FrDLCIS  
  INTEGER as pktSwchSnaPULlc2FrXIDInitiationS  
  Integer32 as pktSwchSnaPULlc2FrN2CountS  
  Integer32 as pktSwchSnaPULlc2FrT1TimerS  
  Integer32 as pktSwchSnaPULlc2FrTiTimerS  
  INTEGER as pktSwchSnaPULlc2FrEntryStatusS  

PktSwchSnaPULlc2FrEntryA  
SEQUENCE    
  Integer32 as pktSwchSnaPULlc2FrNumberA  
  INTEGER as pktSwchSnaPULlc2FrSideA  
  INTEGER as pktSwchSnaPULlc2FrEncapsTypeA  
  OCTET STRING as pktSwchSnaPULlc2FrDestMACA  
  OCTET STRING as pktSwchSnaPULlc2FrSrcSAPA  
  OCTET STRING as pktSwchSnaPULlc2FrDestSAPA  
  OCTET STRING as pktSwchSnaPULlc2FrXIDIdBlkA  
  OCTET STRING as pktSwchSnaPULlc2FrXIDIdNumA  
  Integer32 as pktSwchSnaPULlc2FrMaxPiuSizeA  
  Integer32 as pktSwchSnaPULlc2FrTxWindowA  
  Integer32 as pktSwchSnaPULlc2FrLinkA  
  Integer32 as pktSwchSnaPULlc2FrDLCIA  
  INTEGER as pktSwchSnaPULlc2FrXIDInitiationA  
  Integer32 as pktSwchSnaPULlc2FrN2CountA  
  Integer32 as pktSwchSnaPULlc2FrT1TimerA  
  Integer32 as pktSwchSnaPULlc2FrTiTimerA  

PktSwchSnaPULlc2FrStatEntry  
SEQUENCE    
  Integer32 as pktSwchSnaPULlc2FrStatNumber  
  INTEGER as pktSwchSnaPULlc2FrStatSide  
  Counter32 as pktSwchSnaPULlc2FrStatOctetsIn  
  Counter32 as pktSwchSnaPULlc2FrStatOctetsOut  
  Counter32 as pktSwchSnaPULlc2FrStatIFramesIn  
  Counter32 as pktSwchSnaPULlc2FrStatIFramesOut  
  Counter32 as pktSwchSnaPULlc2FrStatRRFramesIn  
  Counter32 as pktSwchSnaPULlc2FrStatRRFramesOut  
  Counter32 as pktSwchSnaPULlc2FrStatRNRFramesIn  
  Counter32 as pktSwchSnaPULlc2FrStatRNRFramesOut  
  Counter32 as pktSwchSnaPULlc2FrStatXIDsIn  
  Counter32 as pktSwchSnaPULlc2FrStatXIDsOut  
  Counter32 as pktSwchSnaPULlc2FrStatTESTsIn  
  Counter32 as pktSwchSnaPULlc2FrStatTESTsOut  
  Counter32 as pktSwchSnaPULlc2FrStatREJsIn  
  Counter32 as pktSwchSnaPULlc2FrStatREJsOut  
  Counter32 as pktSwchSnaPULlc2FrStatFRMRsIn  
  Counter32 as pktSwchSnaPULlc2FrStatFRMRsOut  
  Counter32 as pktSwchSnaPULlc2FrStatDISCsIn  
  Counter32 as pktSwchSnaPULlc2FrStatDISCsOut  
  Counter32 as pktSwchSnaPULlc2FrStatUAsIn  
  Counter32 as pktSwchSnaPULlc2FrStatUAsOut  
  Counter32 as pktSwchSnaPULlc2FrStatDMsIn  
  Counter32 as pktSwchSnaPULlc2FrStatDMsOut  
  Counter32 as pktSwchSnaPULlc2FrStatSABMEsIn  
  Counter32 as pktSwchSnaPULlc2FrStatSABMEsOut  
  Counter32 as pktSwchSnaPULlc2FrStatRetransmitsIn  
  Counter32 as pktSwchSnaPULlc2FrStatRetransmitsOut  
  INTEGER as pktSwchSnaPULlc2FrStatUpperState  
  INTEGER as pktSwchSnaPULlc2FrStatLowerState  
  INTEGER as pktSwchSnaPULlc2FrStatNRMStatus  
  INTEGER as pktSwchSnaPULlc2FrStatFlowCtlStatus  

PktSwchEthernetLinkEntry  
SEQUENCE    
  INTEGER as pktSwchEthernetLinkOperationMode  
  OCTET STRING as pktSwchEthernetLinkUserDefMacAddr  
  DisplayString as pktSwchEthernetLinkPointToPointDest  
  Counter32 as pktSwchEthernetLinkTotalFramesIn  
  Counter32 as pktSwchEthernetLinkTotalFramesOut  
  Counter32 as pktSwchEthernetLinkIpFramesIn  
  Counter32 as pktSwchEthernetLinkIpFramesOut  
  Counter32 as pktSwchEthernetLinkLlc2FramesIn  
  Counter32 as pktSwchEthernetLinkLlc2FramesOut  
  Counter32 as pktSwchEthernetLinkBridgFramesIn  
  Counter32 as pktSwchEthernetLinkBridgFramesOut  
  Counter32 as pktSwchEthernetLinkDiscardedByFilter  

PktSwchEthernetFilterEntry  
SEQUENCE    
  Integer32 as pktSwchEthernetFilterId  
  OCTET STRING as pktSwchEthernetFilterMacAddr  
  INTEGER as pktSwchEthernetFilterProtType  
  DisplayString as pktSwchEthernetFilterDest  
  INTEGER as pktSwchEthernetFilterStatus  

PktSwchEthernetBroadcastDestEntry  
SEQUENCE    
  INTEGER as pktSwchEthernetBroadcastDestProtocol  
  Integer32 as pktSwchEthernetBroadcastDestId  
  DisplayString as pktSwchEthernetBroadcastDestDestination  
  INTEGER as pktSwchEthernetBroadcastDestStatus  

PktSwchIpInterfaceEntry  
SEQUENCE    
  Integer32 as pktSwchIpInterfaceId  
  IpAddress as pktSwchIpInterfaceAddress  
  IpAddress as pktSwchIpInterfaceAddressMask  
  INTEGER as pktSwchIpInterfaceSendDefRoutMsgOnly  
  DisplayString as pktSwchIpInterfaceDest  
  Integer32 as pktSwchIpInterfaceInactivity  
  Integer32 as pktSwchIpInterfaceLinkCost  
  INTEGER as pktSwchIpInterfaceOptions  
  INTEGER as pktSwchIpInterfaceStatus  
  Counter32 as pktSwchIpInterfaceRxFrames  
  Counter32 as pktSwchIpInterfaceRxExpiredTtl  
  Counter32 as pktSwchIpInterfaceRxUnknownDest  
  Counter32 as pktSwchIpInterfaceTxFrames  
  Counter32 as pktSwchIpInterfaceTxQueueBufs  
  Counter32 as pktSwchIpInterfaceTxDiscarded  
  Counter32 as pktSwchIpInterfaceRipRxFrames  
  Counter32 as pktSwchIpInterfaceRipTxFrames  
  Counter32 as pktSwchIpInterfaceRipWaitingMsgs  

PktSwchIsdnRoutEntry  
SEQUENCE    
  Integer32 as pktSwchIsdnRoutId  
  INTEGER as pktSwchIsdnRoutDataBandWidth  
  INTEGER as pktSwchIsdnRoutOptions  
  INTEGER as pktSwchIsdnRoutStatus  

PktSwchIsdnOutAddrEntry  
SEQUENCE    
  Integer32 as pktSwchIsdnOutAddrRoutId  
  Integer32 as pktSwchIsdnOutAddrId  
  DisplayString as pktSwchIsdnOutAddr  
  DisplayString as pktSwchIsdnOutSubAddr  

PktSwchIsdnAcceptEntry  
SEQUENCE    
  Integer32 as pktSwchIsdnAcceptId  
  Integer32 as pktSwchIsdnAcceptSecondaryLink  
  DisplayString as pktSwchIsdnAcceptDialbkSubAddress  
  INTEGER as pktSwchIsdnAcceptStatus  

PktSwchIsdnLinkEntry  
SEQUENCE    
  INTEGER as pktSwchIsdnLinkBchannel  
  Counter32 as pktSwchIsdnCallsClrs  
  INTEGER as pktSwchIsdnTestCmd  
  DisplayString as pktSwchIsdnTestAddr  
  DisplayString as pktSwchIsdnTestSubAddr  

PktSwchPppSecretsEntry  
SEQUENCE    
  Integer32 as pktSwchPppSecretsPairId  
  INTEGER as pktSwchPppSecretsStatus  

PktSwchPppChanEntry  
SEQUENCE    
  INTEGER as pktSwchPppChanSpeed  
  Integer32 as pktSwchPppChanFlowCtlDuration  
  INTEGER as pktSwchPppChanStopBits  
  Integer32 as pktSwchPppChanBitPerChar  
  INTEGER as pktSwchPppChanParity  
  INTEGER as pktSwchPppChanNegotiationTrigger  
  Integer32 as pktSwchPppChanMRU  
  OCTET STRING as pktSwchPppChanACCM  
  INTEGER as pktSwchPppChanAuthentication  
  INTEGER as pktSwchPppChanInternalClock  
  Integer32 as pktSwchPppChanBundle  
  Integer32 as pktSwchpPppChanIsdnRoutId  
  DisplayString as pktSwchpPppChanLastEvent  

ModmSaConfigEntry  
SEQUENCE    
  INTEGER as modmSaConfigMode  
  INTEGER as modmSaConfigLoopback  
  INTEGER as modmSaConfigAlrClearOnCmd  
  INTEGER as modmSaConfigAlrClearAllCmd  
  INTEGER as modmSaConfigTestClearCmd  
  INTEGER as modmSaConfigClkMaster  
  INTEGER as modmSaConfigResetStatistics  
  Integer32 as modmSaConfigActiveTs  
  INTEGER as modmSaConfigReset  
  INTEGER as modmSaConfigRemote  
  INTEGER as modmSaConfigPsType  
  INTEGER as modmSaConfigWorkMode  

ModmSaStatEntry  
SEQUENCE    
  Integer32 as modmSaStatHwTest  
  OCTET STRING as modmSaStatAlarms  
  INTEGER as modmSaStatClkSrc  
  OCTET STRING as modmSaStatAlarmsMask  
  INTEGER as modmSaStatDeviceType  
  DisplayString as modmSaStatSwVersion  
  DisplayString as modmSaStatHwVersion  

ModmSaAlarmBuffEntry  
SEQUENCE    
  Integer32 as modmSaAlarmBuffIndex  
  Integer32 as modmSaAlarmBuffCode  
  DisplayString as modmSaAlarmBuffTime  
  INTEGER as modmSaAlarmBuffState  

ModmSaRptrEntry  
SEQUENCE    
  Integer32 as modmSaIndex  
  Integer32 as modmSaRptrIndex  
  INTEGER as modmSaRptrTest  
  OCTET STRING as modmSaRptrActiveAlarms  
  INTEGER as modmSaRptrAlrClear  
  DisplayString as modmSaRptrVersion  

MdlParamEntry  
SEQUENCE    
  INTEGER as mdlSIdx  
  Integer32 as mdlSNoOfModems  
  INTEGER as mdlCardType  
  INTEGER as mdlSPanelType  
  OCTET STRING as mdlSLed  
  OCTET STRING as mdlSActiveAlarms  
  INTEGER as mdlAlrClear  
  INTEGER as mdlSConfigMismatch  
  INTEGER as mdlConfigSource  
  INTEGER as mdlConfigGround  

ModemParamEntry  
SEQUENCE    
  Integer32 as modemIdx  
  INTEGER as modemType  
  INTEGER as modemConfigMode  
  INTEGER as modemModeTemporary  
  Integer32 as modemNoOfDte  
  INTEGER as modemWire  
  INTEGER as modemMngLink  
  INTEGER as modemReset  
  INTEGER as modemSlot  
  OCTET STRING as modemHubId  
  IpAddress as modemIpAddress  
  INTEGER as modemPsType  
  Integer32 as modemMaskTraps  
  OCTET STRING as modemActiveAlarms  
  INTEGER as modemAlrClear  
  INTEGER as modemAlrBufClear  
  OCTET STRING as modemMaskSignaling  
  INTEGER as modemPanelType  
  INTEGER as modemIType  
  Integer32 as modemRcvPower  
  Integer32 as modemSwVersion  
  OCTET STRING as modemLed  
  INTEGER as modemRemoteType  
  INTEGER as modemConfigPhantom  
  INTEGER as modemRemoteTestEnable  
  DisplayString as modemSwVerString  
  Integer32 as modemRemoteIdx  
  DisplayString as modemHwVerString  
  INTEGER as modemResetStatistics  
  INTEGER as modemMaxRate  
  INTEGER as modemBoxMaterial  

ModemAlrBufEntry  
SEQUENCE    
  Integer32 as modemAlrBufIdx  
  Integer32 as modemAlrBufCode  
  INTEGER as modemAlrBufState  
  DisplayString as modemAlrBufDate  
  DisplayString as modemAlrBufTime  
  TimeTicks as modemAlrBufSysUpTime  

ModemGeneralEntry  
SEQUENCE    
  Integer32 as modemCurrentElapsedTime  
  Integer32 as modemValidIntervals  

ModemIntervalEntry  
SEQUENCE    
  Integer32 as modemIntervalNumber  
  Integer32 as modemSyncLoss  
  INTEGER as modemLineQuality  
  Integer32 as modemLineUtility  
  Integer32 as modemRTS  
  Integer32 as modemCD  
  DisplayString as modemBertResult  
  OCTET STRING as modemBpvError  
  OCTET STRING as modemFoError  

ModmPrtSpEntry  
SEQUENCE    
  INTEGER as modmPrtSpUsage  
  INTEGER as modmPrtSpRate  
  INTEGER as modmPrtSpDataBits  
  INTEGER as modmPrtSpParity  
  INTEGER as modmPrtSpInterface  
  INTEGER as modmPrtSpCTS  
  INTEGER as modmPrtSpDcdDelay  
  INTEGER as modmPrtSpDsr  

ModmPrtDs1Entry  
SEQUENCE    
  OCTET STRING as modmPrtDs1HdslPriorityBumping  
  INTEGER as modmPrtDs1Sync  
  Gauge32 as modmPrtDs1BpvLastMin  
  Gauge32 as modmPrtDs1BpvMax  
  INTEGER as modmPrtDs1LineLength  
  Gauge32 as modmPrtDs1CRCAvgError  

ModmPrtHdslCurrentEntry  
SEQUENCE    
  Integer32 as modmPrtHdslCurrentElapsedTime  
  Gauge32 as modmPrtHdslCurrentESs  
  Gauge32 as modmPrtHdslCurrentSESs  
  Gauge32 as modmPrtHdslCurrentBBEs  
  Gauge32 as modmPrtHdslCurrentUASs  
  Integer32 as modmPrtHdslCurrentNoiseMargin  
  Integer32 as modmPrtHdslCurrentAttenuation  

ModmPrtHdslIntervalEntry  
SEQUENCE    
  Integer32 as modmPrtHdslIntervalNumber  
  Gauge32 as modmPrtHdslIntervalESs  
  Gauge32 as modmPrtHdslIntervalSESs  
  Gauge32 as modmPrtHdslIntervalBBEs  
  Gauge32 as modmPrtHdslIntervalUASs  
  Integer32 as modmPrtHdslIntervalESR  
  Integer32 as modmPrtHdslIntervalSESR  
  Integer32 as modmPrtHdslIntervalBBER  

ModmPrtHdslTotalEntry  
SEQUENCE    
  Integer32 as modmPrtHdslTotalValidIntervals  
  Gauge32 as modmPrtHdslTotalESs  
  Gauge32 as modmPrtHdslTotalSESs  
  Gauge32 as modmPrtHdslTotalBBEs  
  Gauge32 as modmPrtHdslTotalUASs  

ModmPrtHdslEntry  
SEQUENCE    
  Integer32 as modmPrtHdslIndex  
  Integer32 as modmPrtHdslDedicatedTs  
  OCTET STRING as modmPrtHdslPriorityBumping  
  INTEGER as modmPrtHdslMngProtocol  
  INTEGER as modmPrtHdslRoutProtocol  
  INTEGER as modmPrtHdslInbandMngRate  

ModmPrtDteEntry  
SEQUENCE    
  Integer32 as modmPrtDteIndex  
  INTEGER as modmPrtDteProtocol  
  INTEGER as modmPrtDteDataBits  
  INTEGER as modmPrtDteStopBits  
  INTEGER as modmPrtDteRate  
  INTEGER as modmPrtDteCtsDelay  
  INTEGER as modmPrtDteParity  
  INTEGER as modmPrtDteIfType  
  INTEGER as modmPrtDteRlbEnable  
  INTEGER as modmPrtDteAlbEnable  
  INTEGER as modmPrtDteRtsDcdEnable  
  INTEGER as modmPrtDteDsrDtrEnable  
  OCTET STRING as modmPrtDteSignaling  
  INTEGER as modmPrtDteLoops  
  Integer32 as modmPrtDteTests  
  INTEGER as modmPrtDteClearAllTests  
  DisplayString as modmPrtDteBertResult  
  INTEGER as modmPrtDteErrCorrect  
  INTEGER as modmPrtDteV54DigitalTest  
  INTEGER as modmPrtDteV54DigitalTestStatus  
  Integer32 as modmPrtDteTestTimeOut  

ModmPrtLineEntry  
SEQUENCE    
  Integer32 as modmPrtLineIndex  
  INTEGER as modmPrtLineClkSrc  
  INTEGER as modmPrtLineTxLevel  
  INTEGER as modmPrtLineRxLevel  
  INTEGER as modmPrtLineOutImp  
  INTEGER as modmPrtLineInImp  
  INTEGER as modmPrtLineCarrCntrl  
  INTEGER as modmPrtLineRAP  
  INTEGER as modmPrtLineWaveLength  
  INTEGER as modmPrtLineCdSense  
  INTEGER as modmPrtLineAIS  
  INTEGER as modmPrtLineCoding  
  INTEGER as modmPrtLineLength  
  INTEGER as modmPrtLineClkSrcPort  
  INTEGER as modmPrtLineDteClkConfig  
  INTEGER as modmPrtLineMaskAlr  

SysDclEntry  
SEQUENCE    
  Integer32 as sysDclCnfgIdx  
  INTEGER as sysDclRedundancy  
  INTEGER as sysDclActiveCl  
  INTEGER as sysDclFlipDelay  
  INTEGER as sysDclFlipUponStnClk  

SysDclCopyDbEntry  
SEQUENCE    
  Integer32 as sysDclCopyDbIdx  
  INTEGER as sysDclCopyDbCmd  

SysSErrListEntry  
SEQUENCE    
  INTEGER as sysSErrType  
  Integer32 as sysSErrIdx  
  DisplayString as sysSErrDescription SIZE(0..255)  

SysSRdnFlipEntry  
SEQUENCE    
  Integer32 as sysSRdnFlipIdx  
  INTEGER as sysSRdnFlipSlot  
  Integer32 as sysSRdnFlipPort  
  DisplayString as sysSRdnFlipCause  
  DisplayString as sysSRdnFlipDate  
  DisplayString as sysSRdnFlipTime  

SysSBusEntry  
SEQUENCE    
  Integer32 as sysSBusPortIdx  
  INTEGER as sysSBusStatus  
  Integer32 as sysSBusCapturePort  
  Integer32 as sysSBusUtilization  

SysSRdnCmdEntry  
SEQUENCE    
  INTEGER as sysSRdnEnforcedChannel  

SysSAlrEntry  
SEQUENCE    
  Integer32 as sysSAlrIdx  
  Integer32 as sysSAlrCode  
  INTEGER as sysSAlrState  
  INTEGER as sysSAlarmMask  
  INTEGER as sysSAlarmInvert  
  INTEGER as sysSAlarmOnOff  
  Integer32 as sysSAlarmCounter  

SysBufferAlrEntry  
SEQUENCE    
  Integer32 as sysBufferAlrIdx  
  Integer32 as sysBufferAlrCode  
  INTEGER as sysBufferAlrState  
  INTEGER as sysBufferAlrSlot  
  Integer32 as sysBufferAlrPort  
  DisplayString as sysBufferAlrDate  
  DisplayString as sysBufferAlrTime  

SysCClkSrcEntry  
SEQUENCE    
  Integer32 as sysCClkCnfgIdx  
  INTEGER as sysCClkSrcIdx  
  INTEGER as sysCClkSrcMode  
  Integer32 as sysCClkSrcPrt  
  INTEGER as sysCClkStationFreq  
  Integer32 as sysCClkRevertiveTimeout  
  INTEGER as sysCClkStationIf  

SysCnfgEntry  
SEQUENCE    
  Integer32 as sysCnfgIdx  
  INTEGER as sysCMatrixMode  
  INTEGER as sysCIsdnFormat  
  INTEGER as sysCRoutingOnEth  
  INTEGER as sysCAutoConfigEnable  
  INTEGER as sysCIntTsAllocMode  

SysCRdnEntry  
SEQUENCE    
  Integer32 as sysCRdnCnfgIdx  
  INTEGER as sysCRdnPrimeSlot  
  Integer32 as sysCRdnPrimePort  
  INTEGER as sysCRdnSecSlot  
  Integer32 as sysCRdnSecPort  
  INTEGER as sysCRdnMode  
  INTEGER as sysCRdnRecMode  
  Integer32 as sysCRdnRecTime  
  INTEGER as sysCRdnHwSwFlip  
  RowStatus as sysCRdnRowStatus  
  INTEGER as sysCRdnOnline  
  INTEGER as sysCRdnSwitchingMode  
  Integer32 as sysCRdnFlipUponEvent  
  Integer32 as sysCRdnLosOrLofTime  
  Integer32 as sysCRdnEventsTimeWindow  
  Integer32 as sysCRdnSequenceNumberThreshold  
  Integer32 as sysCRdnBufferErrorsThreshold  
  Integer32 as sysCRdnBuffUnderrunTime  

SysDbaseFlipEntry  
SEQUENCE    
  Integer32 as sysDbaseFlipIdx  
  DisplayString as sysDbaseFlipTime  
  INTEGER as sysDbaseFlipActivation  

MdlSEntry  
SEQUENCE    
  INTEGER as mdlSSltIdx  
  INTEGER as mdlSCardType  
  DisplayString as mdlSHwVer SIZE(0..255)  
  DisplayString as mdlSSwVer SIZE(0..255)  
  INTEGER as mdlSAlarmStatus  
  INTEGER as mdlSAlarmStatusAll  
  INTEGER as mdlSTestStatus  
  INTEGER as mdlSHwStatus  
  INTEGER as mdlSActivity  
  INTEGER as mdlSAlrClearCmd  
  INTEGER as mdlSAlrClearAllCmd  
  INTEGER as mdlSAlrMaskAll  
  Integer32 as mdlSCmd  
  INTEGER as mdlSReset  
  INTEGER as mdlSRebuildFrame  

MdlCEntry  
SEQUENCE    
  Integer32 as mdlCConfigIdx  
  INTEGER as mdlCSlotIdx  
  INTEGER as mdlCProgCardType  
  Integer32 as mdlCNoOfExtPrt  
  Integer32 as mdlCNoOfIntPrt  
  Integer32 as mdlCParam  

MdlAlrEntry  
SEQUENCE    
  INTEGER as mdlAlrSltIdx  
  Integer32 as mdlAlrIdx  
  Integer32 as mdlAlrCode  
  INTEGER as mdlAlrState  
  INTEGER as mdlAlarmMask  
  INTEGER as mdlAlarmInvert  
  INTEGER as mdlAlarmOnOff  
  Integer32 as mdlAlarmCounter  

MdlAlrMaskEntry  
SEQUENCE    
  INTEGER as mdlAlrMaskSltIdx  
  OCTET STRING as mdlAlrMask  

MdlClEntry  
SEQUENCE    
  INTEGER as mdlClIdx  
  Integer32 as mdlClSwchStatus  
  DisplayString as mdlClLastFlipDate  
  DisplayString as mdlClLastFlipTime  
  DisplayString as mdlClLastFlipCause  

MdlPsEntry  
SEQUENCE    
  INTEGER as mdlPsIdx  
  INTEGER as mdlPsStatus  
  INTEGER as mdlPsTestResult  

PrtGenEntry  
SEQUENCE    
  Integer32 as prtGenPrtIdx  
  INTEGER as prtGenSlt  
  INTEGER as prtGenExtInt  
  Integer32 as prtGenIfIndex  
  INTEGER as prtGenActiveStatus  
  INTEGER as prtGenAlrStatus  
  INTEGER as prtGenTestStatus  
  Integer32 as prtGenTestMask  
  Integer32 as prtGenTestCmd  
  Integer32 as prtGenTestRunning  
  INTEGER as prtGenType  
  DisplayString as prtGenInterfaceType SIZE(0..255)  
  INTEGER as prtGenAlrClearCmd  
  INTEGER as prtGenAlrMaskAll  
  OCTET STRING as prtGenParamStatus  
  INTEGER as prtGenRdnStatus  
  OCTET STRING as prtGenTestMaskXP  
  OCTET STRING as prtGenTestCmdXP  
  OCTET STRING as prtGenTestRunningXP  

PrtGenTestDurationEntry  
SEQUENCE    
  Integer32 as prtGenTestPrtIdx  
  INTEGER as prtGenTestIdx  
  Integer32 as prtGenTestDuration  

PrtGenTsEntry  
SEQUENCE    
  Integer32 as prtGenTsCnfgIdx  
  Integer32 as prtGenTsPrtIdx  
  Integer32 as prtGenTsIdx  
  INTEGER as prtGenTsType  
  Integer32 as prtGenTsIConPrt  
  Integer32 as prtGenTsIConTs  

PrtSAlarmEntry  
SEQUENCE    
  Integer32 as prtSAlarmPrtIdx  
  Integer32 as prtSAlarmIdx  
  Integer32 as prtSAlarmCode  
  INTEGER as prtSAlarmState  
  INTEGER as prtSAlarmMask  
  INTEGER as prtSAlarmInvert  
  INTEGER as prtSAlarmOnOff  
  Integer32 as prtSAlarmCounter  

PrtAlrMaskEntry  
SEQUENCE    
  Integer32 as prtAlrMaskPrtIdx  
  OCTET STRING as prtAlrMask  

PrtBertEntry  
SEQUENCE    
  Integer32 as prtBertPrtIdx  
  INTEGER as prtBertPattern  
  INTEGER as prtBertInjectRate  
  INTEGER as prtBertInjectErrRateCmd  
  INTEGER as prtBertInjectSingleErrCmd  
  Integer32 as prtBertRunTime  
  Integer32 as prtBertESs  
  Integer32 as prtBertSyncLoss  
  Integer32 as prtBertErrorBits  
  INTEGER as prtBertClearCounters  
  INTEGER as prtBertSyncStatus  
  OCTET STRING as prtBertTs  
  DisplayString as prtBertResult SIZE(0..255)  

PrtMonEntry  
SEQUENCE    
  Integer32 as prtMonCnfgIdx  
  Integer32 as prtMonitoringIdx  
  INTEGER as prtMonitoringEnable  
  OCTET STRING as prtMonitoringTSs  
  Integer32 as prtMonitoredPort  
  OCTET STRING as prtMonitoredTSs  

PrtCfgParamEntry  
SEQUENCE    
  Integer32 as prtCfgParamCnfgIdx  
  Integer32 as prtCfgParamIdx  
  INTEGER as prtCfgParamSlt  
  INTEGER as prtCfgParamOperatedMl  
  INTEGER as prtCfgParamMlAtoMlBPrio  
  INTEGER as prtCfgParamMlBtoMlAPrio  
  INTEGER as prtCfgParamInbandLoopDetection  

PrtT1E1StatEntry  
SEQUENCE    
  Integer32 as prtT1E1SPrtIdx  
  INTEGER as prtT1E1SSlt  
  Gauge32 as prtT1E1OosCount  
  Gauge32 as prtT1E1BpvLastMin  
  Gauge32 as prtT1E1BpvMax  

PrtT1E1CnfgEntry  
SEQUENCE    
  Integer32 as prtT1E1CnfgIdx  
  Integer32 as prtT1E1PrtIdx  
  INTEGER as prtT1E1Slt  
  INTEGER as prtT1E1LineType  
  INTEGER as prtT1E1LineCode  
  INTEGER as prtT1E1SignalMode  
  INTEGER as prtT1E1Fdl  
  INTEGER as prtT1E1FdlMode  
  INTEGER as prtT1E1Sync  
  INTEGER as prtT1E1CGA  
  OCTET STRING as prtT1E1IdleCode  
  INTEGER as prtT1E1OosSignal  
  OCTET STRING as prtT1E1VoiceOos  
  OCTET STRING as prtT1E1DataOos  
  INTEGER as prtT1E1LineLengthMask  
  INTEGER as prtT1E1TxGainMask  
  INTEGER as prtT1E1InbandMng  
  INTEGER as prtT1E1InbandMngRate  
  Integer32 as prtT1E1DedicatedTs  
  INTEGER as prtT1E1InbandMngRoutProt  
  INTEGER as prtT1E1LinkMode  
  INTEGER as prtT1E1Multiplier  
  INTEGER as prtT1E1RxGain  
  INTEGER as prtT1E1RAI  
  INTEGER as prtT1E1LineMode  
  OCTET STRING as prtT1E1TS0SaBits  
  INTEGER as prtT1E1ConnectedTS  
  INTEGER as prtT1E1Ts0SaBit  
  INTEGER as prtT1E1SameFeCnfg  
  INTEGER as prtT1E1RemCrc4  
  Integer32 as prtT1E1MaxTSs  
  INTEGER as prtT1E1EocTsConfig  

PrtT1E1FdlMsgEntry  
SEQUENCE    
  Integer32 as prtT1E1FdlMsgPrtIdx  
  INTEGER as prtT1E1FdlMsgFdlType  
  INTEGER as prtT1E1FdlMsgSlt  
  OCTET STRING as prtT1E1FdlMsg  

PrtHSParamEntry  
SEQUENCE    
  Integer32 as prtHSCnfgIdx  
  Integer32 as prtHSPrtIdx  
  INTEGER as prtHSSlt  
  INTEGER as prtHSRate  
  INTEGER as prtHSFifoSize  
  INTEGER as prtHSClkMode  
  INTEGER as prtHSCTS  
  INTEGER as prtHSRtsState  
  INTEGER as prtHSInbandLoopback  
  INTEGER as prtHSInbandLoopPatternCfg  
  DisplayString as prtHSInbandLoopActPattern  
  DisplayString as prtHSInbandLoopDeactPattern  
  INTEGER as prtHSDCD  

PrtHSBertEntry  
SEQUENCE    
  Integer32 as prtHSBertPrtIdx  
  INTEGER as prtHSBertSlt  
  INTEGER as prtHSBertCountClr  
  Integer32 as prtHSBertTestResult  

PrtSpCnfgEntry  
SEQUENCE    
  Integer32 as prtSpCnfgIdx  
  Integer32 as prtSpPrtIdx  
  INTEGER as prtSpUsage  
  INTEGER as prtSpRate  
  INTEGER as prtSpDataBits  
  INTEGER as prtSpParity  
  INTEGER as prtSpCallOutMode  
  INTEGER as prtSpInterface  
  INTEGER as prtSpCTS  
  INTEGER as prtSpDcdDelay  
  INTEGER as prtSpDsr  
  Integer32 as prtSpNoOfRetries  
  INTEGER as prtSpWaitForConnect  
  INTEGER as prtSpDialMode  
  INTEGER as prtSpAltNumMode  
  DisplayString as prtSpPrimaryNum  
  DisplayString as prtSpAltNum  
  INTEGER as prtSpRoutProtocol  
  OCTET STRING as prtSpCmd  
  INTEGER as prtSpActCallOut  
  INTEGER as prtSpAlrRelayMode  
  INTEGER as prtSpStopBits  

PrtDimCnfgEntry  
SEQUENCE    
  Integer32 as prtDimCnfgIdx  
  Integer32 as prtDimIdx  
  INTEGER as prtDimTxMode  
  INTEGER as prtDimPolarity  
  INTEGER as prtDimClkMode  
  INTEGER as prtDimMaxDelay  
  INTEGER as prtDimMng  

PrtDimDestEntry  
SEQUENCE    
  Integer32 as prtDestCnfgIdx  
  Integer32 as prtDestDimIdx  
  Integer32 as prtDestIdx  
  Integer32 as prtDest  
  INTEGER as prtDestConnect  

PrtICnfgEntry  
SEQUENCE    
  Integer32 as prtICnfgIdx  
  Integer32 as prtIIdx  
  INTEGER as prtIRate  
  INTEGER as prtIConnect  

PrtHdslEntry  
SEQUENCE    
  Integer32 as prtHdslIdx  
  INTEGER as prtHdslMode  
  INTEGER as prtHdslRptrType  
  INTEGER as prtHdslMaxRate  
  INTEGER as prtHdslLinkType  
  DisplayString as prtHdslCompSwVer  
  DisplayString as prtHdslCompHwVer  

PrtT3E3CnfgEntry  
SEQUENCE    
  Integer32 as prtT3E3CnfgIdx  
  Integer32 as prtT3E3PrtIdx  
  INTEGER as prtT3E3Slt  
  INTEGER as prtT3E3LineLength  
  INTEGER as prtT3E3InbandMng  
  INTEGER as prtT3E3AisFrame  
  INTEGER as prtT3E3TxClockSource  
  INTEGER as prtT3E3RoutProt  

CmprEntry  
SEQUENCE    
  Integer32 as cmprTypeIdx  
  Integer32 as cmprCnfgIdx  
  Integer32 as cmprVersion  
  INTEGER as cmprSltIdx  
  Integer32 as cmprPrtIdx  
  OCTET STRING as cmprObj  

MapLinkEntry  
SEQUENCE    
  Integer32 as mapLinkIdx  
  INTEGER as mapLinkSlotIdx  
  Integer32 as mapLinkPortIdx  
  INTEGER as mapLinkState  

AlrGenEntry  
SEQUENCE    
  Integer32 as alrGenCode  
  DisplayString as alrGenDescription SIZE(0..255)  
  INTEGER as alrGenLevel  
  INTEGER as alrGenSlotType  
  INTEGER as alrGenSeverity  
  Integer32 as alrGenDebounce  
  INTEGER as alrGenDefSeverity  

SysGenKmuxEntry  
SEQUENCE    
  Integer32 as sysGenConfigIdx  
  INTEGER as sysGenFlipIntegration  
  INTEGER as sysGenMlMode  
  INTEGER as sysGenFaType  
  INTEGER as sysGenLinkRecovery  
  INTEGER as sysGenLinkSourceClock  
  Integer32 as sysGenMngBwA  
  Integer32 as sysGenMngBwB  
  Integer32 as sysGenAutoDialSlot  
  INTEGER as sysGenResetBypassEnable  

SysBackupEntry  
SEQUENCE    
  Integer32 as sysBackupConfigIdx  
  INTEGER as sysBackupDatabase  
  INTEGER as sysBackupMode  
  INTEGER as sysBackupDialTimeout  
  INTEGER as sysBackupOptions  

SysBackupAgendaEntry  
SEQUENCE    
  INTEGER as sysBackupCfgIdx  
  INTEGER as sysBackupDay  
  INTEGER as sysBackupZone  
  DisplayString as sysBackupEndTime  
  INTEGER as sysBackupStatus  

SysFrameAllocationEntry  
SEQUENCE    
  Integer32 as sysFaConfigIdx  
  INTEGER as sysFaLink  
  Integer32 as sysFaPrt  
  Integer32 as sysFaStartingBit  
  Integer32 as sysFaNumOfBits  

SysDisconnectSupervisionEventEntry  
SEQUENCE    
  Integer32 as sysDsEventIdx  
  INTEGER as sysDsEventSlot  
  Integer32 as sysDsEventTS  
  DisplayString as sysDsEventDescr  
  DisplayString as sysDsEventDateAndTime  

MdlKmxEntry  
SEQUENCE    
  Integer32 as mdlKmxConfigIdx  
  INTEGER as mdlKmxSlotIdx  
  INTEGER as mdlKmxOperatedMl  
  INTEGER as mdlKmxMlAtoMlBPrio  
  INTEGER as mdlKmxMlBtoMlAPrio  
  INTEGER as mdlKmxOutSrvMethod  
  INTEGER as mdlKmxV54Config  
  INTEGER as mdlKmxTiming  

MdlKvf5PbxEntry  
SEQUENCE    
  Integer32 as mdlKvf5PbxConfigIdx  
  INTEGER as mdlKvf5PbxSlotIdx  
  INTEGER as mdlKvf5PbxSig  
  INTEGER as mdlKvf5PbxSigMode  
  INTEGER as mdlKvf5PbxTsAssign  
  Integer32 as mdlKvf5PbxCcsTs  
  INTEGER as mdlKvf5PbxOos  
  INTEGER as mdlKvf5PbxSigTxPbx  
  INTEGER as mdlKvf5PbxSigRxPbx  
  OCTET STRING as mdlKvf5PbxDefABCD  
  INTEGER as mdlKvf5PbxFramerSlot  
  INTEGER as mdlKvf5PbxCcsRate  
  OCTET STRING as mdlKvf5PbxTxAbcdBit  
  INTEGER as mdlKvf5PbxHdlcCrc  

MdlDisconnectSupervisionEntry  
SEQUENCE    
  Integer32 as mdlDsConfigIdx  
  INTEGER as mdlDsSlotIdx  
  INTEGER as mdlDs  
  INTEGER as mdlDsUserLoc  
  INTEGER as mdlDsMode  
  Integer32 as mdlDsSilence  
  OCTET STRING as mdlDsClrFwSig  
  OCTET STRING as mdlDsAnswerSig  
  OCTET STRING as mdlDsClrBwSig  
  Integer32 as mdlDsFbtLowFreq  
  Integer32 as mdlDsFbtHighFreq  
  Integer32 as mdlDsFbtTimeOn1  
  Integer32 as mdlDsFbtTimeOff1  
  Integer32 as mdlDsFbtTimeOn2  
  Integer32 as mdlDsFbtTimeOff2  
  Integer32 as mdlDsFbtLowFreqLevel  
  Integer32 as mdlDsFbtHighFreqLevel  

PrtMlFrameStatsEntry  
SEQUENCE    
  Integer32 as prtMlFrameIdx  
  INTEGER as prtMlFrameSlt  
  INTEGER as prtMlBitWeight  
  Integer32 as prtMlDataUsage  
  Integer32 as prtMlControlSig  
  Integer32 as prtMlDownload  
  Integer32 as prtMlSync  
  Integer32 as prtMlTotalUsage  
  Integer32 as prtMlTotalFree  

PrtMlEntry  
SEQUENCE    
  Integer32 as prtMlCnfgIdx  
  Integer32 as prtMlIdx  
  INTEGER as prtMlSlt  
  INTEGER as prtMlTiming  
  INTEGER as prtMlBufferSize  
  INTEGER as prtMlDsrCts  
  INTEGER as prtMlSpeed  
  Integer32 as prtMlStartTS  
  INTEGER as prtMlBypassTs16  
  INTEGER as prtMlCallMode  
  INTEGER as prtMlBondingEnable  

PrtMlIsdnEntry  
SEQUENCE    
  Integer32 as prtMlIsdnCnfgIdx  
  Integer32 as prtMlIsdnIdx  
  INTEGER as prtMlIsdnSlt  
  INTEGER as prtMlIsdnMode  
  INTEGER as prtMlIsdnStandard  
  DisplayString as prtMlIsdnLocSubNum  
  DisplayString as prtMlIsdnLocNum  
  DisplayString as prtMlIsdnOutSubNum  
  DisplayString as prtMlIsdnBackupCallNum  
  INTEGER as prtMlIsdnInNumMode  

PrtHsLsEntry  
SEQUENCE    
  Integer32 as prtHsLsCnfgIdx  
  Integer32 as prtHsLsIdx  
  INTEGER as prtHsLsSlt  
  INTEGER as prtHsLsCommProtocol  
  INTEGER as prtHsLsAsyncDataLen  
  INTEGER as prtHsLsTiming  
  INTEGER as prtHsLsCtrlSignal  
  INTEGER as prtHsLsCts  
  INTEGER as prtHsLsRtsCtsDelay  
  INTEGER as prtHsLsDsrMode  
  INTEGER as prtHsLsSpeed  
  INTEGER as prtHsLsUType  

PrtTreMbeEntry  
SEQUENCE    
  Integer32 as prtTreMbeCnfgIdx  
  Integer32 as prtTreMbeIdx  
  INTEGER as prtTreMbeSlt  
  INTEGER as prtTreMbeLan  
  INTEGER as prtTreMbeLanRate  
  INTEGER as prtTreMbeLinkSpeed  

PrtVoiceFaxEntry  
SEQUENCE    
  Integer32 as prtVoiceFaxCnfgIdx  
  Integer32 as prtVoiceFaxIdx  
  INTEGER as prtVoiceFaxSlt  
  Integer32 as prtVoiceFaxTransGain  
  Integer32 as prtVoiceFaxReceiveGain  
  INTEGER as prtVoiceFaxWire  
  INTEGER as prtVoiceFaxTimeOut  
  INTEGER as prtVoiceFaxEchoCanceler  
  INTEGER as prtVoiceFaxSpeed  
  INTEGER as prtVoiceFaxMeterRate  
  INTEGER as prtVoiceFaxCodingLaw  
  INTEGER as prtVoiceFaxOperMode  
  OCTET STRING as prtVoiceFaxSigInOutband  
  INTEGER as prtVoiceFaxTsGroup  
  Integer32 as prtVoiceFaxRxFaxGain  
  INTEGER as prtVoiceFaxSigHold  
  INTEGER as prtVoiceFaxIfSignaling  
  INTEGER as prtVoiceFaxEMTypes  
  INTEGER as prtVoiceFaxRingFrequency  
  OCTET STRING as prtVoiceFaxSignalingStatus  

SysGenAlarmBuffEntry  
SEQUENCE    
  Integer32 as sysGenAlarmBuffIndex  
  DisplayString as sysGenAlarmDescr  

SysGenLogEntry  
SEQUENCE    
  Integer32 as sysGenLogIndex  
  DisplayString as sysGenLogDescr  

SysCallProfileEntry  
SEQUENCE    
  Integer32 as sysCallProfileIndex  
  INTEGER as sysCallProfileConnectCmd  
  INTEGER as sysCallProfileDisconnectCmd  
  Integer32 as sysCallProfileIncrBwCmd  
  Integer32 as sysCallProfileDecrBwCmd  

PrtCnfgEntry  
SEQUENCE    
  Integer32 as prtIndex  
  Integer32 as prtCnfgDecrBwChNum  
  Integer32 as prtCnfgIncrBwChNum  
  INTEGER as prtCnfgDisconnect  
  INTEGER as prtCnfgActivateLoop  
  INTEGER as prtCnfgClearLoop  
  Integer32 as prtCnfgLoopStatus  

ChannelCnfgEntry  
SEQUENCE    
  Integer32 as chIndex  
  INTEGER as chCnfgUnlock  
  INTEGER as chCnfgPing  

ChannelStatEntry  
SEQUENCE    
  INTEGER as chStatOperStatus  

AtmNteConfIfEntry  
SEQUENCE    
  INTEGER as atmConfIfTransmitClk  
  INTEGER as atmConfIfLoopback  
  INTEGER as atmConfIfFrameType  
  INTEGER as atmConfIfCardType  
  INTEGER as atmConfAtmIfVpiVciLimit  
  INTEGER as atmConfIfHwFeatures  
  Integer32 as atmConfIfOutputRate  
  Integer32 as atmConfIfInputRate  
  INTEGER as atmConfAlarmForwarding  

AtmNteAlarmIfEntry  
SEQUENCE    
  Integer32 as atmInterfaceActiveAlarms  
  Integer32 as atmThresholdSectionBIP  
  Integer32 as atmThresholdLineBIP  
  Integer32 as atmThresholdLineFEBE  
  Integer32 as atmThresholdPathBIP  
  Integer32 as atmThresholdPathFEBE  
  Integer32 as atmThresholdErroredCells  
  Integer32 as atmThresholdLostCells  
  Integer32 as atmThresholdMisinsertedCells  
  INTEGER as atmInterfaceAlarmStatus  
  Integer32 as atmInterfaceMaskAlarms  

AtmNteConfVpEntry  
SEQUENCE    
  INTEGER as atmConfVpPolicing  
  INTEGER as atmConfVpCCAdminStatus  
  INTEGER as atmConfVpLoopbackAdminStatus  
  OCTET STRING as atmConfVpLoopbackSinkAddress  
  OCTET STRING as atmConfVpCongestionControl  
  INTEGER as atmConfVpCCDirection  
  DateAndTime as atmConfVpCreationTime  
  INTEGER as atmConfVpOamSupport  
  INTEGER as atmConfVpCCOperStatus  
  INTEGER as atmConfVpLoopbackTraffic  
  INTEGER as atmConfVpLoopbackFailureInd  
  Integer32 as atmConfVpLoopbackFailureThreshold  
  INTEGER as atmConfVpOamDirection  

AtmNteAlarmVpEntry  
SEQUENCE    
  Integer32 as atmNteVpAlarmVpi  
  Integer32 as atmNteVpActiveAlarms  

AtmNteAlarmVcEntry  
SEQUENCE    
  Integer32 as atmNteVcAlarmVpi  
  Integer32 as atmNteVcAlarmVci  
  Integer32 as atmNteVcActiveAlarms