RAD-BROADBAND-IF-MIB

File: RAD-BROADBAND-IF-MIB.mib (45589 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RAD-MIB
IF-MIB SNMP-FRAMEWORK-MIB

Imported symbols

OBJECT-TYPE Integer32 Gauge32
RowStatus TruthValue diverseIfWanGen
InterfaceIndex SnmpAdminString

Defined Objects

broadbandIf 1.3.6.1.4.1.164.3.1.6.8
OBJECT IDENTIFIER    

bdbandConfig 1.3.6.1.4.1.164.3.1.6.8.1
OBJECT IDENTIFIER    

prtBdbandIndTable 1.3.6.1.4.1.164.3.1.6.8.1.1
The Indication Signal table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtBdbandIndEntry

prtBdbandIndEntry 1.3.6.1.4.1.164.3.1.6.8.1.1.1
An entry in the Indication Signal table.
OBJECT-TYPE    
  PrtBdbandIndEntry  

prtBdbandCnfgIdx 1.3.6.1.4.1.164.3.1.6.8.1.1.1.1
This object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1.
OBJECT-TYPE    
  Integer32 1..255  

prtBdbandIdx 1.3.6.1.4.1.164.3.1.6.8.1.1.1.2
This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex.
OBJECT-TYPE    
  Integer32  

prtBdbandIndSig 1.3.6.1.4.1.164.3.1.6.8.1.1.1.3
This object indicates a unique Indication Signal. ais(1) = AIS = Alarm Indication Signal. rdi(2) = RDI = Remote Defect Indication.
OBJECT-TYPE    
  INTEGER ais(1), rdi(2), aisAndRdi(3)  

prtBdbandIndEvent 1.3.6.1.4.1.164.3.1.6.8.1.1.1.4
This object indicates a unique Event that can cause the Indication Signal. slm(2) = SLM = Signal Label Mismatch eed(4) = EED = Excessive Error Defect pathTrace(5) = the end-to-end source/destination of information is wrong.
OBJECT-TYPE    
  INTEGER notApplicable(1), slm(2), fail(3), eed(4), pathTrace(5)  

prtBdbandIndSigEnable 1.3.6.1.4.1.164.3.1.6.8.1.1.1.5
This object allows user to define if the event specified by prtBdbandIndEvent will cause creation of the Indication Signal specified by prtBdbandIndSig or not. disable - will not enable causing the signal enable - will enable causing the signal.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtBdbandRowStatus 1.3.6.1.4.1.164.3.1.6.8.1.1.1.6
Creation/Deletion of rows in the table.
OBJECT-TYPE    
  RowStatus  

prtPhyConfigTable 1.3.6.1.4.1.164.3.1.6.8.1.2
The Phy Config table. Used now for Phy25.6 Mbps.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhyConfigEntry

prtPhyConfigEntry 1.3.6.1.4.1.164.3.1.6.8.1.2.1
An entry in the Phy Config table.
OBJECT-TYPE    
  PrtPhyConfigEntry  

prtPhyTimeElapsed 1.3.6.1.4.1.164.3.1.6.8.1.2.1.1
The number of seconds that have elapsed since the beginning of the current error-measurement period.
OBJECT-TYPE    
  Integer32 0..899  

prtPhyValidIntervals 1.3.6.1.4.1.164.3.1.6.8.1.2.1.2
The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute since the interface has been online.
OBJECT-TYPE    
  Integer32 0..96  

prtPhyPerfHistory 1.3.6.1.4.1.164.3.1.6.8.2
OBJECT IDENTIFIER    

prtPhyCurrentTable 1.3.6.1.4.1.164.3.1.6.8.2.1
The 25.6 Mbps Section/Line Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhyCurrentEntry

prtPhyCurrentEntry 1.3.6.1.4.1.164.3.1.6.8.2.1.1
An entry in the 25.6 Mbps Line Current table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps.
OBJECT-TYPE    
  PrtPhyCurrentEntry  

prtPhyCurrentLOS 1.3.6.1.4.1.164.3.1.6.8.2.1.1.1
The counter associated with the number of Loss Of Sync seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentLSV 1.3.6.1.4.1.164.3.1.6.8.2.1.1.2
The counter associated with the number of Line symbol violation seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentUAS 1.3.6.1.4.1.164.3.1.6.8.2.1.1.3
The counter associated with the number of UAS encountered by a 25.6 Mbps interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentSES 1.3.6.1.4.1.164.3.1.6.8.2.1.1.4
The counter associated with the number of SES encountered by a 25.6 Mbps interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentES 1.3.6.1.4.1.164.3.1.6.8.2.1.1.5
The number of Errored Seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentStatus 1.3.6.1.4.1.164.3.1.6.8.2.1.1.6
The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

prtPhyCurrentLOF 1.3.6.1.4.1.164.3.1.6.8.2.1.1.7
The number of Loss of Frames, encountered by an interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalTable 1.3.6.1.4.1.164.3.1.6.8.2.2
The Line Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhyIntervalEntry

prtPhyIntervalEntry 1.3.6.1.4.1.164.3.1.6.8.2.2.1
An entry in the 25.6 Mbps Line Interval table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps.
OBJECT-TYPE    
  PrtPhyIntervalEntry  

prtPhyIntervalNumber 1.3.6.1.4.1.164.3.1.6.8.2.2.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
OBJECT-TYPE    
  Integer32 1..96  

prtPhyIntervalLOS 1.3.6.1.4.1.164.3.1.6.8.2.2.1.2
The counter associated with the number of Loss Of Sync seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalLSV 1.3.6.1.4.1.164.3.1.6.8.2.2.1.3
The counter associated with the number of line symbol violation seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalUAS 1.3.6.1.4.1.164.3.1.6.8.2.2.1.4
The counter associated with the number of UAS encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalSES 1.3.6.1.4.1.164.3.1.6.8.2.2.1.5
The counter associated with the number of SES encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalES 1.3.6.1.4.1.164.3.1.6.8.2.2.1.6
The number of Errored Seconds, encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalStatus 1.3.6.1.4.1.164.3.1.6.8.2.2.1.7
The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

prtPhyIntervalLOF 1.3.6.1.4.1.164.3.1.6.8.2.2.1.8
The number of Loss of Frames, encountered by an interface in one of the previous 96, individual 15 minute intervals.
OBJECT-TYPE    
  Gauge32  

r2If 1.3.6.1.4.1.164.3.1.6.9
OBJECT IDENTIFIER    

r2ProfileCnfg 1.3.6.1.4.1.164.3.1.6.9.1
OBJECT IDENTIFIER    

r2CnfgTable 1.3.6.1.4.1.164.3.1.6.9.1.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    R2CnfgEntry

r2CnfgEntry 1.3.6.1.4.1.164.3.1.6.9.1.1.1
An entry in table.
OBJECT-TYPE    
  R2CnfgEntry  

r2CnfgIdx 1.3.6.1.4.1.164.3.1.6.9.1.1.1.1
This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. Write is allowed only to TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

r2CnfgProfileIdx 1.3.6.1.4.1.164.3.1.6.9.1.1.1.2
Profile Index. Valid values: 1..5 Only instances of profiles that are defined having agnSigProfType=r2Cas will exist in this table.
OBJECT-TYPE    
  Integer32  

r2Mode 1.3.6.1.4.1.164.3.1.6.9.1.1.1.3
R2 Mode. auto - in this mode, default value of timers will be used by R2, according to the selected r2Country. manual - in this mode, user can change the value of R2 timers within the valid limits, specific to each country.
OBJECT-TYPE    
  INTEGER auto(2), manual(3)  

r2Country 1.3.6.1.4.1.164.3.1.6.9.1.1.1.4
R2 Country. R2 Timers can have different range of values and defaults for each country. When r2Mode=auto, the default value is used by R2 according to this selected country. 1=ITU-T (standard values) 2=Korea 3=India 4=Brasil (continuous) 5=Brasil (pulsed) 6..10 - reserved for future countries.
OBJECT-TYPE    
  Integer32  

r2Delay 1.3.6.1.4.1.164.3.1.6.9.1.1.1.5
This object enables user to configure the link as satellite or terrestrial. The seize acknowledge detect timing is much shorter (msec) for terrestrial link than for satellite link (1-2 sec).
OBJECT-TYPE    
  INTEGER notApplicable(1), terrestrial(2), satellite(3)  

r2MeteringInd 1.3.6.1.4.1.164.3.1.6.9.1.1.1.6
Which Bit will be used for Metering Indication.
OBJECT-TYPE    
  INTEGER notApplicable(1), cBit(2), bBit(3)  

r2BreakMakeRatio 1.3.6.1.4.1.164.3.1.6.9.1.1.1.7
This object describes the Break-Make Ratio of Pulse Duration, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  INTEGER notApplicable(1), break56Make44(2), break64Make36(3), break80Make20(4)  

r2ReleaseGuardT2 1.3.6.1.4.1.164.3.1.6.9.1.1.1.8
Release Guard timing T2. Release guard timing before going to idle, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2Regret 1.3.6.1.4.1.164.3.1.6.9.1.1.1.9
Regret duration, in [sec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2SeizeDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.10
Seize Detect. Timer of the R2 incoming side. Minimum duration to detect a valid seizure, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2SeizeAckDelay 1.3.6.1.4.1.164.3.1.6.9.1.1.1.11
Timer of the R2 incoming side. Delay before sending a valid seize ack signal, in [msec]. Applicable only when r2Mode=manual. only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2ClearBackDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.12
Timer of the R2 incoming side. Minimum duration to recognize a valid clear-back, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2ClearFwdDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.13
Timer of the R2 incoming side. Minimum duration to recognize a valid clear-forward, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2FaultDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.14
Timer of the R2 incoming side. Minimum duration to recognize a block signal, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2FaultRemoveDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.15
Timer of the R2 incoming side. Minimum duration to recognize a valid block removal signal, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2MeterPulseDuration 1.3.6.1.4.1.164.3.1.6.9.1.1.1.16
Timer of the R2 incoming side. Duration of metering pulse to be sent, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2SeizeAckWait 1.3.6.1.4.1.164.3.1.6.9.1.1.1.17
Timer of the R2 outgoing side. Minimum duration to receive seizure acknowledge signal, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2SeizeAckDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.18
Timer of the R2 outgoing side. Minimum duration to recognize a valid seizure acknowledge signal, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2AnswerDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.19
Timer of the R2 outgoing side. Minimum duration to recognize a valid answer signal, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2BlockRemoveDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.20
Timer of the R2 outgoing side. Minimum duration to recognize a valid block removal signal, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2MeterPulseDetect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.21
Timer of the R2 outgoing side. Minimum duration of incoming meter pulse, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2ForcedDisconnect 1.3.6.1.4.1.164.3.1.6.9.1.1.1.22
Timer of the R2 outgoing side. Minimum duration to recognize disconnect signal, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2DisconnectAck 1.3.6.1.4.1.164.3.1.6.9.1.1.1.23
Timer of the R2 outgoing side. Minimum duration to recognize disconnect acknowledge signal, in [msec]. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2ReleaseGuardT1 1.3.6.1.4.1.164.3.1.6.9.1.1.1.24
Timer of the R2 outgoing side. Minimum duration to release guard, in [msec]. During this time, no new call can be initiated. RW only when r2Mode=manual.
OBJECT-TYPE    
  Integer32  

r2CnfgRowStatus 1.3.6.1.4.1.164.3.1.6.9.1.1.1.25
This object enables the user to add/delete entries to/from the table.
OBJECT-TYPE    
  RowStatus  

r2TsTable 1.3.6.1.4.1.164.3.1.6.9.1.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    R2TsEntry

r2TsEntry 1.3.6.1.4.1.164.3.1.6.9.1.2.1
An entry in table.
OBJECT-TYPE    
  R2TsEntry  

r2TsCnfgIdx 1.3.6.1.4.1.164.3.1.6.9.1.2.1.1
This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. Write is allowed only to TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

r2TsProfileIdx 1.3.6.1.4.1.164.3.1.6.9.1.2.1.2
Profile Index. Valid values: 1..5 Only instances of profiles that are defined having agnSigProfType=r2Cas will exist in this table.
OBJECT-TYPE    
  Integer32  

r2TsIdx 1.3.6.1.4.1.164.3.1.6.9.1.2.1.3
TS Index. Valid values: 1..31
OBJECT-TYPE    
  Integer32  

r2TsCallEnable 1.3.6.1.4.1.164.3.1.6.9.1.2.1.4
This object indicates the Enabled Call direction for the specific TS.
OBJECT-TYPE    
  INTEGER incoming(2), outgoing(3), both(4)  

r2TsMetering 1.3.6.1.4.1.164.3.1.6.9.1.2.1.5
This object indicates if the specific TS should support Metering.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

r2TsRowStatus 1.3.6.1.4.1.164.3.1.6.9.1.2.1.6
This object enables the user to add/delete entries to/from the table.
OBJECT-TYPE    
  RowStatus  

r2TsReversePolarity 1.3.6.1.4.1.164.3.1.6.9.1.2.1.7
This object indicates if the specific TS should support Reverse Polarity.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

r2IfStatus 1.3.6.1.4.1.164.3.1.6.9.2
OBJECT IDENTIFIER    

r2StatusTable 1.3.6.1.4.1.164.3.1.6.9.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    R2StatusEntry

r2StatusEntry 1.3.6.1.4.1.164.3.1.6.9.2.1.1
An entry in table.
OBJECT-TYPE    
  R2StatusEntry  

r2StatusSlotIdx 1.3.6.1.4.1.164.3.1.6.9.2.1.1.1
Slot Index
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

r2StatusPortIdx 1.3.6.1.4.1.164.3.1.6.9.2.1.1.2
This object indicates a unique port number of the ML having R2 interface. Valid values: exPrt1 (1)..exPrt4 (4)
OBJECT-TYPE    
  Integer32  

r2StatusTsIdx 1.3.6.1.4.1.164.3.1.6.9.2.1.1.3
Time Slot index.
OBJECT-TYPE    
  Integer32 1..31  

r2StatusSigDirection 1.3.6.1.4.1.164.3.1.6.9.2.1.1.4
R2 Time Slot Signaling Direction.
OBJECT-TYPE    
  INTEGER notApplicable(1), incoming(2), outgoing(3)  

r2StatusTsState 1.3.6.1.4.1.164.3.1.6.9.2.1.1.5
R2 TS State
OBJECT-TYPE    
  INTEGER notUsed(1), normal(2), remoteBlocked(3), localBlocked(4), localLoop(5), remoteLoop(6)  

r2StatusProtocolState 1.3.6.1.4.1.164.3.1.6.9.2.1.1.6
R2 Protocol State.
OBJECT-TYPE    
  INTEGER idle(1), seized(2), seizureAcknowledged(3), answered(4), clearForward(5), clearBack(6), blocked(7), forcedDisc(8), doubleSeizure(9), fault(10), discAcknowledged(11), fault1(12), fault6(13), fault3(14)  

atmLayer2 1.3.6.1.4.1.164.12.7
OBJECT IDENTIFIER    

atmLayer2XVclTable 1.3.6.1.4.1.164.12.7.1
This table is an extension of VCL table, which is created for each LAN VCC.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLayer2XVclEntry

atmLayer2XVclEntry 1.3.6.1.4.1.164.12.7.1.1
Conceptual row in atmVclTable. This table augments the RFC2515 VCL table.
OBJECT-TYPE    
  AtmLayer2XVclEntry  

atmLayer2XVclConnMode 1.3.6.1.4.1.164.12.7.1.1.1
Each valid LAN VCC is either Main or Sub. This parameter is configured only once on creation of a LAN VCC. It can not be changed after creation. In order to change the Mode, user should delete the connection and create a new one. main - A LAN VCC, which holds its own bridge port. Bridge forwarding and Bridge learning is performed only on Main VCCs. For working on a transparent bridge, that doesn't perform layer 2 priority mapping, a Main VCC should be opened, which is the default connection Mode. When working with layer 2 priority, a group of LAN VCCs should be configured, where each group will be associated with only one Main VCC. A specific Main can not be used by more than one group. sub - A LAN VCC is not part of the bridging mechanism. A Sub VCC automatically inherit some general definitions from Main VCC of its group: ATM Slot/Port and LAN Slot/Port. Max number of Sub VCCs allowed per group is: [Number of Priorities - 1].
OBJECT-TYPE    
  INTEGER main(1), sub(2)  

atmLayer2XVclGroupIdx 1.3.6.1.4.1.164.12.7.1.1.2
The group identifier. A VCC Group identifier = 0 if the VCC was not associated with a group yet. This value is updated according to the group identifier set by atmLayer2GroupTable.
OBJECT-TYPE    
  Integer32  

atmLayer2GroupTable 1.3.6.1.4.1.164.12.7.2
This table contains groups and their members. A group is a bundle of VCCs, which acts as different queues. Main and Sub VCCs should have the same ATM slot and port, and the same LAN slot and port. Each group contains: 1 to VCCs.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLayer2GroupEntry

atmLayer2GroupEntry 1.3.6.1.4.1.164.12.7.2.1
Conceptual row in atmLayer2GroupTable. The indexes: ifIndex, atmVclVpi and atmVclVci indicate the Network ATM End-Point. Upon a group creation, one Main VCC must be added first. After the group was created, Sub VCCs may be added to the group.
OBJECT-TYPE    
  AtmLayer2GroupEntry  

atmLayer2GroupIdx 1.3.6.1.4.1.164.12.7.2.1.1
The group identifier. 0 is not a valid index.
OBJECT-TYPE    
  Integer32  

atmLayer2GroupRowStatus 1.3.6.1.4.1.164.12.7.2.1.2
Creation/Deletion of rows in the table, and indication of the entry's status.
OBJECT-TYPE    
  RowStatus  

atmLayer2GroupConnMode 1.3.6.1.4.1.164.12.7.2.1.3
Each valid LAN VCC is either Main or Sub as configured in atmLayer2XVclTable.
OBJECT-TYPE    
  INTEGER main(1), sub(2)  

atmLayer2GroupConnPriority 1.3.6.1.4.1.164.12.7.2.1.4
This parameter is configured by atmLayer2PriorityRx from atmLayer2PriorityTable. Each bit in the Octet represents a specific priority as follows: MSB 7 6 5 4 3 2 1 0 LSB -> Priorities |--------------------| 1 0 0 1 0 0 0 1 -> Value In this example, a certain VCC has several priorities: 0, 4 and 7.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

atmLayer2GroupName 1.3.6.1.4.1.164.12.7.2.1.5
Group name. Configured by the user. The name is unique per system. For atmLayer2GroupIdx=0, the name will be null.
OBJECT-TYPE    
  SnmpAdminString SIZE(1..32)  

atmLayer2PriorityTable 1.3.6.1.4.1.164.12.7.3
This table maps all priorities inside a group. Several priorities might be mapped to the same VCC. Upon priority change, the agent will update the VCCs of the changed priority in this table, and will update - atmLayer2GroupConnPriority parameter of both former and new owners of the changed priority. Changing a VCC value is actually a change of three parameters simultaneously: atmLayer2PriorityIfIndex, atmLayer2PriorityVclVpi and atmLayer2PriorityVclVci. Otherwise, the set will be rejected, since there might be that such VCC doesn't exist in the specific group.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLayer2PriorityEntry

atmLayer2PriorityEntry 1.3.6.1.4.1.164.12.7.3.1
Conceptual row in atmLayer2PriorityTable. Each entry is a Network ATM End-Point per priority. Upon a group creation, all priorities are mapped to the Main VCC. Number of entries per group is according to the number of priorities enabled. (For example, for Max priorities = 8, the agent will create 8 entries).
OBJECT-TYPE    
  AtmLayer2PriorityEntry  

atmLayer2PriorityGroupIdx 1.3.6.1.4.1.164.12.7.3.1.1
The group identifier.
OBJECT-TYPE    
  Integer32  

atmLayer2PriorityRx 1.3.6.1.4.1.164.12.7.3.1.2
The priority values. The used values are 0-7, but since this value is part of the index of the table, and in order to avoid '0' as an index, the index syntax is 1..8, but the real value is atmLayer2PriorityRx-1: 0 - for Low priority. 7 - for High priority.
OBJECT-TYPE    
  Integer32 1..8  

atmLayer2PriorityIfIndex 1.3.6.1.4.1.164.12.7.3.1.3
ATM ifIndex of the network End-Point.
OBJECT-TYPE    
  InterfaceIndex  

atmLayer2PriorityVclVpi 1.3.6.1.4.1.164.12.7.3.1.4
Vpi of the network End-Point.
OBJECT-TYPE    
  Integer32  

atmLayer2PriorityVclVci 1.3.6.1.4.1.164.12.7.3.1.5
Vci of the network End-Point.
OBJECT-TYPE    
  Integer32  

atmLayer2GroupIndexNext 1.3.6.1.4.1.164.12.7.4
This object contains an appropriate value to be used for atmLayer2GroupIdx when creating entries in the atmLayer2GroupTable. The value 0 indicates that no unassigned entries are available. To obtain the atmLayer2GroupIdx value for a new entry, the manager gets the current value of this object. The next index will be of the first unassigned entry. It will be provided by checking the assigned entries.
OBJECT-TYPE    
  Integer32 0..2147483647  

atmLayer2CfgTable 1.3.6.1.4.1.164.12.7.5
Bridge configuration Table. This table supports multi-bridge and bridge features within an ATM device.
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLayer2CfgEntry

atmLayer2CfgEntry 1.3.6.1.4.1.164.12.7.5.1
Conceptual row in atmLayer2CfgTable. Each entry in this table contains the bridging attributes for both Ethernet and ATM sides. The interface index is the Ethernet port interface. For Ace52: this object represents the Bridge ifIndex.
OBJECT-TYPE    
  AtmLayer2CfgEntry  

atmLayer2CfgBridgingMode 1.3.6.1.4.1.164.12.7.5.1.1
Bridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs.
OBJECT-TYPE    
  INTEGER accessOnly(1), accessAndSwitching(2)  

atmLayer2CfgVlanMode 1.3.6.1.4.1.164.12.7.5.1.2
VLAN Mode. Upon Mode changing, all LAN VCCs will be deleted by the agent from all tables that include LAN VCCs.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

atmLayer2CfgAtmAcceptableFrameType 1.3.6.1.4.1.164.12.7.5.1.3
The Frame Type that will be acceptable by the VCCs that are associated with this Ethernet port. Frames which don't match the selected type will be discarded. admitAll - all frames will be accepted. admitOnlyVlanTagged - only Tagged frames will be accepted. admitOnlyUnTagged - only unTagged frames will be accepted.
OBJECT-TYPE    
  INTEGER notApplicable(1), admitAll(2), admitOnlyVlanTagged(3), admitOnlyUnTagged(4)  

atmLayer2CfgAtmIngressFiltering 1.3.6.1.4.1.164.12.7.5.1.4
For the VCCs that are associated with this Ethernet port, when this is true(1) the device will discard incoming frames for VLANs which do not include this Port in its Member set. When false(2), the port will accept all incoming frames.
OBJECT-TYPE    
  TruthValue  

atmLayer2CfgAtmTxFrameType 1.3.6.1.4.1.164.12.7.5.1.5
The Frame Type that will be transmitted by the VCCs that are associated with this Ethernet port. unTagged - The transmitted frames will be unTagged. tagged - The transmitted frames will be Tagged.
OBJECT-TYPE    
  INTEGER notApplicable(1), unTagged(2), tagged(3)  

atmLayer2CfgEthAcceptableFrameType 1.3.6.1.4.1.164.12.7.5.1.6
The Frame Type that this Ethernet port will accept. (for ACE-52: the Frame Type that this Bridge will accept) This parameter is notApplicable for atmLayer2VlanMode=disable. Frames which don't match the selected type will be discarded. admitAll - all frames will be accepted. admitOnlyVlanTagged - only Tagged frames will be accepted. admitOnlyUnTagged - only unTagged frames will be accepted.
OBJECT-TYPE    
  INTEGER notApplicable(1), admitAll(2), admitOnlyVlanTagged(3), admitOnlyUnTagged(4)  

atmLayer2CfgBridgeAction 1.3.6.1.4.1.164.12.7.5.1.7
This object enables to perform the specified action on the selected port.
OBJECT-TYPE    
  INTEGER deleteLanTable(7), noOp(255)  

atmLayer2CfgLearningMode 1.3.6.1.4.1.164.12.7.5.1.8
This object specifies the mode of the learning process of a bridge. svl - Shared VLAN process. If an individual MAC Address is learned in one VLAN, this information is used in forwarding decisions taken for that address for all other VLANs. ivl - Independent VLAN process. If an individual MAC Address is learned in one VLAN, this information is not used in forwarding decisions taken for that address for all other VLANs.
OBJECT-TYPE    
  INTEGER svl(1), ivl(2)  

atmLayer2CfgAgingTime 1.3.6.1.4.1.164.12.7.5.1.9
The timeout period in seconds for aging out dynamically learned forwarding information.
OBJECT-TYPE    
  Integer32  

radAtmFr 1.3.6.1.4.1.164.12.8
OBJECT IDENTIFIER    

frAtmIwfXConnectionTable 1.3.6.1.4.1.164.12.8.1
This table is an extension of frAtmIwfXConnectionTable from RFC2955.
OBJECT-TYPE    
  SEQUENCE OF  
    FrAtmIwfXConnectionEntry

frAtmIwfXConnectionEntry 1.3.6.1.4.1.164.12.8.1.1
Conceptual row in frAtmIwfXConnectionTable. This table augments the RFC2955.
OBJECT-TYPE    
  FrAtmIwfXConnectionEntry  

frAtmIwfXConnMode 1.3.6.1.4.1.164.12.8.1.1.1
FR IWF Mode. service - Service InterWorking (FRF.8), network - Network InterWorking (FRF.5).
OBJECT-TYPE    
  INTEGER service(1), network(2)  

frAtmIwfXConnSscsDlci 1.3.6.1.4.1.164.12.8.1.1.2
This parameter is relevant for frAtmIwfXConnMode=network (FRF.5) only. This parameter allow configuration of the FR SSCS DLCI that is transferred to the remote FR unit.
OBJECT-TYPE    
  Integer32  

Defined Objects

PrtBdbandIndEntry  
SEQUENCE    
  Integer32 as prtBdbandCnfgIdx  
  Integer32 as prtBdbandIdx  
  INTEGER as prtBdbandIndSig  
  INTEGER as prtBdbandIndEvent  
  INTEGER as prtBdbandIndSigEnable  
  RowStatus as prtBdbandRowStatus  

PrtPhyConfigEntry  
SEQUENCE    
  Integer32 as prtPhyTimeElapsed  
  Integer32 as prtPhyValidIntervals  

PrtPhyCurrentEntry  
SEQUENCE    
  Gauge32 as prtPhyCurrentLOS  
  Gauge32 as prtPhyCurrentLSV  
  Gauge32 as prtPhyCurrentUAS  
  Gauge32 as prtPhyCurrentSES  
  Gauge32 as prtPhyCurrentES  
  OCTET STRING as prtPhyCurrentStatus  
  Gauge32 as prtPhyCurrentLOF  

PrtPhyIntervalEntry  
SEQUENCE    
  Integer32 as prtPhyIntervalNumber  
  Gauge32 as prtPhyIntervalLOS  
  Gauge32 as prtPhyIntervalLSV  
  Gauge32 as prtPhyIntervalUAS  
  Gauge32 as prtPhyIntervalSES  
  Gauge32 as prtPhyIntervalES  
  OCTET STRING as prtPhyIntervalStatus  
  Gauge32 as prtPhyIntervalLOF  

R2CnfgEntry  
SEQUENCE    
  Integer32 as r2CnfgIdx  
  Integer32 as r2CnfgProfileIdx  
  INTEGER as r2Mode  
  Integer32 as r2Country  
  INTEGER as r2Delay  
  INTEGER as r2MeteringInd  
  INTEGER as r2BreakMakeRatio  
  Integer32 as r2ReleaseGuardT2  
  Integer32 as r2Regret  
  Integer32 as r2SeizeDetect  
  Integer32 as r2SeizeAckDelay  
  Integer32 as r2ClearBackDetect  
  Integer32 as r2ClearFwdDetect  
  Integer32 as r2FaultDetect  
  Integer32 as r2FaultRemoveDetect  
  Integer32 as r2MeterPulseDuration  
  Integer32 as r2SeizeAckWait  
  Integer32 as r2SeizeAckDetect  
  Integer32 as r2AnswerDetect  
  Integer32 as r2BlockRemoveDetect  
  Integer32 as r2MeterPulseDetect  
  Integer32 as r2ForcedDisconnect  
  Integer32 as r2DisconnectAck  
  Integer32 as r2ReleaseGuardT1  
  RowStatus as r2CnfgRowStatus  

R2TsEntry  
SEQUENCE    
  Integer32 as r2TsCnfgIdx  
  Integer32 as r2TsProfileIdx  
  Integer32 as r2TsIdx  
  INTEGER as r2TsCallEnable  
  INTEGER as r2TsMetering  
  RowStatus as r2TsRowStatus  
  INTEGER as r2TsReversePolarity  

R2StatusEntry  
SEQUENCE    
  INTEGER as r2StatusSlotIdx  
  Integer32 as r2StatusPortIdx  
  Integer32 as r2StatusTsIdx  
  INTEGER as r2StatusSigDirection  
  INTEGER as r2StatusTsState  
  INTEGER as r2StatusProtocolState  

AtmLayer2XVclEntry  
SEQUENCE    
  INTEGER as atmLayer2XVclConnMode  
  Integer32 as atmLayer2XVclGroupIdx  

AtmLayer2GroupEntry  
SEQUENCE    
  Integer32 as atmLayer2GroupIdx  
  RowStatus as atmLayer2GroupRowStatus  
  INTEGER as atmLayer2GroupConnMode  
  OCTET STRING as atmLayer2GroupConnPriority  
  SnmpAdminString as atmLayer2GroupName  

AtmLayer2PriorityEntry  
SEQUENCE    
  Integer32 as atmLayer2PriorityGroupIdx  
  Integer32 as atmLayer2PriorityRx  
  InterfaceIndex as atmLayer2PriorityIfIndex  
  Integer32 as atmLayer2PriorityVclVpi  
  Integer32 as atmLayer2PriorityVclVci  

AtmLayer2CfgEntry  
SEQUENCE    
  INTEGER as atmLayer2CfgBridgingMode  
  INTEGER as atmLayer2CfgVlanMode  
  INTEGER as atmLayer2CfgAtmAcceptableFrameType  
  TruthValue as atmLayer2CfgAtmIngressFiltering  
  INTEGER as atmLayer2CfgAtmTxFrameType  
  INTEGER as atmLayer2CfgEthAcceptableFrameType  
  INTEGER as atmLayer2CfgBridgeAction  
  INTEGER as atmLayer2CfgLearningMode  
  Integer32 as atmLayer2CfgAgingTime  

FrAtmIwfXConnectionEntry  
SEQUENCE    
  INTEGER as frAtmIwfXConnMode  
  Integer32 as frAtmIwfXConnSscsDlci