RAD-IMA-MIB

File: RAD-IMA-MIB.mib (5696 bytes)

Imported modules

SNMPv2-SMI RAD-MIB IMA-MIB

Imported symbols

OBJECT-TYPE NOTIFICATION-TYPE Integer32
radAtm imaGroupFailureStatus

Defined Objects

atmImaGroupStatusChangeTrap 1.3.6.1.4.1.164.6.1.12.0.80
This trap indicates IMA Group status change.
NOTIFICATION-TYPE    
  imaGroupFailureStatus  

radAtmIma 1.3.6.1.4.1.164.12.5
OBJECT IDENTIFIER    

imaPrimaryClk 1.3.6.1.4.1.164.12.5.1
Clock source to be transmitted to the user side, where user module is in 'External' clock source.
OBJECT-TYPE    
  INTEGER notApplicable(1), link1(2), link2(3), link3(4), link4(5), automatic(6)  

imaXLinkTable 1.3.6.1.4.1.164.12.5.2
The IMA Link Status and Configuration table. This table contains additional objects for the link table.
OBJECT-TYPE    
  SEQUENCE OF  
    ImaXLinkEntry

imaXLinkEntry 1.3.6.1.4.1.164.12.5.2.1
An entry in the IMA Link table.
OBJECT-TYPE    
  ImaXLinkEntry  

imaLinkDirection 1.3.6.1.4.1.164.12.5.2.1.1
the Link direction.
OBJECT-TYPE    
  INTEGER rx(1), tx(2), both(3)  

imaLinkItcLBClkSrc 1.3.6.1.4.1.164.12.5.2.1.2
Clock source for the current Tx-line.
OBJECT-TYPE    
  INTEGER link1(1), link2(2), link3(3), link4(4), internal(5), external(6), automatic(7), loopback(8)  

imaXGroupTable 1.3.6.1.4.1.164.12.5.3
The IMA group Status and Configuration table. This table contains additional objects for the Group table.
OBJECT-TYPE    
  SEQUENCE OF  
    ImaXGroupEntry

imaXGroupEntry 1.3.6.1.4.1.164.12.5.3.1
An entry in the IMA Group table.
OBJECT-TYPE    
  ImaXGroupEntry  

imaGroupVersion 1.3.6.1.4.1.164.12.5.3.1.1
IMA Version.
OBJECT-TYPE    
  INTEGER ver10(1), ver11(2)  

imaGroupCtcTxClkSrc 1.3.6.1.4.1.164.12.5.3.1.2
The source of the transmitted, common, Clock Source. Applicable if imaGroupNeTxClkMode=ctc(1). Automatic - Dynamic source, taken from the currently reference link. Internal - taken from the Internal clock on card. Loopback - Looped back from one of the ports. In this case a specific port should be selected for imaGroupCtcTxClkSrcPort parameter. Link N - Clock will be looped from one of the links.
OBJECT-TYPE    
  INTEGER link1(1), link2(2), link3(3), link4(4), internal(5), external(6), automatic(7), loopback(8), notApplicable(255)  

imaGroupCtcTxClkSrcPort 1.3.6.1.4.1.164.12.5.3.1.3
This parameter is valid only when imaGroupCtcTxClkSrc=loopback. The value may be any port identifier.
OBJECT-TYPE    
  Integer32  

Defined Objects

ImaXLinkEntry  
SEQUENCE    
  INTEGER as imaLinkDirection  
  INTEGER as imaLinkItcLBClkSrc  

ImaXGroupEntry  
SEQUENCE    
  INTEGER as imaGroupVersion  
  INTEGER as imaGroupCtcTxClkSrc  
  Integer32 as imaGroupCtcTxClkSrcPort