RAD-SONET-MIB

File: RAD-SONET-MIB.mib (96859 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RAD-MIB
PerfHist-TC-MIB SNMP-FRAMEWORK-MIB IF-MIB

Imported symbols

OBJECT-TYPE Integer32 Gauge32
Counter64 IpAddress DisplayString
RowStatus diverseIfWanGen PerfCurrentCount
PerfIntervalCount SnmpAdminString InterfaceIndex

Defined Objects

sonetInterface 1.3.6.1.4.1.164.3.1.6.2
OBJECT IDENTIFIER    

prtSonetPerfHistory 1.3.6.1.4.1.164.3.1.6.2.1
OBJECT IDENTIFIER    

prtSonetMediumTable 1.3.6.1.4.1.164.3.1.6.2.1.1
The SONET Medium table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSonetMediumEntry

prtSonetMediumEntry 1.3.6.1.4.1.164.3.1.6.2.1.1.1
An entry in the SONET Medium table. ifIndex of the lowest SONET layer of type sonet(39).
OBJECT-TYPE    
  PrtSonetMediumEntry  

prtSonetMediumTimeElapsed 1.3.6.1.4.1.164.3.1.6.2.1.1.1.1
The number of seconds that have elapsed since the beginning of the near end current error- measurement period.
OBJECT-TYPE    
  Integer32 0..899  

prtSonetMediumValidIntervals 1.3.6.1.4.1.164.3.1.6.2.1.1.1.2
The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online.
OBJECT-TYPE    
  Integer32 0..96  

prtSonetSectionLineCurrentTable 1.3.6.1.4.1.164.3.1.6.2.1.2
The SONET Section/Line Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSectionLineCurrentEntry

prtSectionLineCurrentEntry 1.3.6.1.4.1.164.3.1.6.2.1.2.1
An entry in the SONET Section/Line Current table. ifIndex of the section/line SONET layer of type sonet(39).
OBJECT-TYPE    
  PrtSectionLineCurrentEntry  

prtSonetCurrentLOS 1.3.6.1.4.1.164.3.1.6.2.1.2.1.1
The counter associated with the number of LOS seconds, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentLOF 1.3.6.1.4.1.164.3.1.6.2.1.2.1.2
The counter associated with the number of LOF seconds, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentLineAIS 1.3.6.1.4.1.164.3.1.6.2.1.2.1.3
The counter associated with the number of Line AIS seconds, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentLineFERF 1.3.6.1.4.1.164.3.1.6.2.1.2.1.4
The counter associated with the number of Line FERF seconds, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentSectionBIP 1.3.6.1.4.1.164.3.1.6.2.1.2.1.5
The counter associated with the number of Section BIP errors, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentLineBIP 1.3.6.1.4.1.164.3.1.6.2.1.2.1.6
The counter associated with the number of Line BIP errors, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentLineFEBE 1.3.6.1.4.1.164.3.1.6.2.1.2.1.7
The counter associated with the number of Line FEBE errors, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentUAS 1.3.6.1.4.1.164.3.1.6.2.1.2.1.8
The counter associated with the number of UAS encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentSES 1.3.6.1.4.1.164.3.1.6.2.1.2.1.9
The counter associated with the number of SES encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentES 1.3.6.1.4.1.164.3.1.6.2.1.2.1.10
The number of Errored Seconds, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentStatus 1.3.6.1.4.1.164.3.1.6.2.1.2.1.11
The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

prtSonetCurrentLSV 1.3.6.1.4.1.164.3.1.6.2.1.2.1.12
The counter associated with the number of LSV seconds (Line Symbol Violation), encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetSectionLineIntervalTable 1.3.6.1.4.1.164.3.1.6.2.1.3
The Section/Line Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSectionLineIntervalEntry

prtSectionLineIntervalEntry 1.3.6.1.4.1.164.3.1.6.2.1.3.1
An entry in the SONET Section/Line Interval table. ifIndex of the section/line SONET layer of type sonet(39).
OBJECT-TYPE    
  PrtSectionLineIntervalEntry  

prtSonetLineIntervalNumber 1.3.6.1.4.1.164.3.1.6.2.1.3.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
OBJECT-TYPE    
  Integer32 1..96  

prtSonetIntervalLOS 1.3.6.1.4.1.164.3.1.6.2.1.3.1.2
The counter associated with the number of LOS seconds , encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalLOF 1.3.6.1.4.1.164.3.1.6.2.1.3.1.3
The counter associated with the number of LOF seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalLineAIS 1.3.6.1.4.1.164.3.1.6.2.1.3.1.4
The counter associated with the number of Line AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalLineFERF 1.3.6.1.4.1.164.3.1.6.2.1.3.1.5
The counter associated with the number of Line FERF seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalSectionBIP 1.3.6.1.4.1.164.3.1.6.2.1.3.1.6
The counter associated with the number of Section BIP errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalLineBIP 1.3.6.1.4.1.164.3.1.6.2.1.3.1.7
The counter associated with the number of Line BIP errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalLineFEBE 1.3.6.1.4.1.164.3.1.6.2.1.3.1.8
The counter associated with the number of Line FEBE errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalUAS 1.3.6.1.4.1.164.3.1.6.2.1.3.1.9
The counter associated with the number of UAS encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalSES 1.3.6.1.4.1.164.3.1.6.2.1.3.1.10
The counter associated with the number of SES encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalES 1.3.6.1.4.1.164.3.1.6.2.1.3.1.11
The number of Errored Seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalStatus 1.3.6.1.4.1.164.3.1.6.2.1.3.1.12
The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
OBJECT-TYPE    
  OCTET STRING SIZE(4)  

prtSonetIntervalLSV 1.3.6.1.4.1.164.3.1.6.2.1.3.1.13
The counter associated with the number of LSV seconds (Line Symbol Violation), encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetPathCurrentTable 1.3.6.1.4.1.164.3.1.6.2.1.4
The SONET Path Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPathCurrentEntry

prtPathCurrentEntry 1.3.6.1.4.1.164.3.1.6.2.1.4.1
An entry in the SONET Path Current table. ifIndex of the Path SONET layer of type sonetPath(50).
OBJECT-TYPE    
  PrtPathCurrentEntry  

prtSonetCurrentPathAIS 1.3.6.1.4.1.164.3.1.6.2.1.4.1.1
The counter associated with the number of Path AIS seconds, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentPathFERF 1.3.6.1.4.1.164.3.1.6.2.1.4.1.2
The counter associated with the number of Path FERF seconds, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentLOP 1.3.6.1.4.1.164.3.1.6.2.1.4.1.3
The counter associated with the number LOP seconds, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentSLM 1.3.6.1.4.1.164.3.1.6.2.1.4.1.4
The counter associated with the number of SLM seconds, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentLOC 1.3.6.1.4.1.164.3.1.6.2.1.4.1.5
The counter associated with the number of LOC seconds, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentPathBIP 1.3.6.1.4.1.164.3.1.6.2.1.4.1.6
The counter associated with the number of Path BIP errors, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetCurrentPathFEBE 1.3.6.1.4.1.164.3.1.6.2.1.4.1.7
The counter associated with the number of Path FEBE errors, encountered by a SONET interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge32  

prtSonetPathIntervalTable 1.3.6.1.4.1.164.3.1.6.2.1.5
The Path Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPathIntervalEntry

prtPathIntervalEntry 1.3.6.1.4.1.164.3.1.6.2.1.5.1
An entry in the SONET Path Interval table.
OBJECT-TYPE    
  PrtPathIntervalEntry  

prtSonetPathIntervalNumber 1.3.6.1.4.1.164.3.1.6.2.1.5.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
OBJECT-TYPE    
  Integer32 1..96  

prtSonetIntervalPathAIS 1.3.6.1.4.1.164.3.1.6.2.1.5.1.2
The counter associated with the number of Path AIS seconds , encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalPathFERF 1.3.6.1.4.1.164.3.1.6.2.1.5.1.3
The counter associated with the number of Path FERF seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalLOP 1.3.6.1.4.1.164.3.1.6.2.1.5.1.4
The counter associated with the number of LOP seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalSLM 1.3.6.1.4.1.164.3.1.6.2.1.5.1.5
The counter associated with the number of SLM seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalLOC 1.3.6.1.4.1.164.3.1.6.2.1.5.1.6
The counter associated with the number of LOC seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalPathBIP 1.3.6.1.4.1.164.3.1.6.2.1.5.1.7
The counter associated with the number of Path BIP errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

prtSonetIntervalPathFEBE 1.3.6.1.4.1.164.3.1.6.2.1.5.1.8
The counter associated with the number of Path FEBE errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
OBJECT-TYPE    
  Gauge32  

virtualIfStatistics 1.3.6.1.4.1.164.3.1.6.2.1.6
OBJECT IDENTIFIER    

virtualIfCurrentTable 1.3.6.1.4.1.164.3.1.6.2.1.6.1
The Virtual Interface Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualIfCurrentEntry

virtualIfCurrentEntry 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1
An entry in the Virtual Interface Current table.
OBJECT-TYPE    
  VirtualIfCurrentEntry  

virtualIfCurrentMinActiveVC 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.1
This object holds the minimum number of active virtual containers (VCs) of the Virtual Concatenation Group in the current 15-minute interval.
OBJECT-TYPE    
  Integer32 1..63  

virtualIfCurrentMaxActiveVC 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.2
This object holds the maximum number of active virtual containers (VCs) of the Virtual Concatenation Group in the current 15-minute interval.
OBJECT-TYPE    
  Integer32 1..63  

virtualIfCurrentRxFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.3
This counter is associated with the number of frames received from STS-3/STM-1 by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  Counter64  

virtualIfCurrentTxFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.4
This counter is associated with the number of frames transmitted to STS-3/STM-1 by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  Counter64  

virtualIfCurrentRxAbortFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.5
The counter associated with the number of Received Aborted frames encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfCurrentTxAbortFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.6
The counter associated with the number of Transmitted Aborted frames encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfCurrentMinLengthViolation 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.7
This counter is associated with the number of Rx payload Min Length Violation frames encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfCurrentMaxLengthViolation 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.8
This counter is associated with the number of Rx payload Max Length Violation frames encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfCurrentFcsError 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.9
The counter is associated with the number of Frame Check Sequence errors encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfCurrentByteDestuffingViolation 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.10
The counter associated with the number of Byte De-stuffing Violations encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfCurrentAdressMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.11
The counter associated with the number of Adress Mismatch encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfCurrentControlMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.12
The counter associated with the number of Control Mismatch encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfCurrentActiveVC 1.3.6.1.4.1.164.3.1.6.2.1.6.1.1.13
This object holds the number of active virtual containers (VCs) of the Virtual Concatenation Group in the current 15-minute interval.
OBJECT-TYPE    
  Integer32 1..64  

virtualIfIntervalTable 1.3.6.1.4.1.164.3.1.6.2.1.6.2
The Virtual Interface Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualIfIntervalEntry

virtualIfIntervalEntry 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1
An entry in the Virtual Interface Interval table.
OBJECT-TYPE    
  VirtualIfIntervalEntry  

virtualIfIntervalNumber 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.1
A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
OBJECT-TYPE    
  Integer32 1..96  

virtualIfIntervalMinActiveVC 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.2
This object holds the minimum number of active virtual containers (VCs) of the Virtual Concatenation Group, in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Integer32 1..64  

virtualIfIntervalMaxActiveVC 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.3
This object holds the maximum number of active virtual containers (VCs) of the Virtual Concatenation Group, in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Integer32 1..64  

virtualIfIntervalRxFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.4
This counter is associated with the number of frames received from STS-3/STM-1 by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Counter64  

virtualIfIntervalTxFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.5
This counter is associated with the number of frames transmitted to STS-3/STM-1 by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Counter64  

virtualIfIntervalRxAbortFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.6
This counter is associated with the number of Received Abort frames encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfIntervalTxAbortFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.7
This counter is associated with the number of Transmitted Abort frames encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfIntervalMinLengthViolation 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.8
This counter is associated with the number of Rx payload Min Length Violation frames encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfIntervalMaxLengthViolation 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.9
This counter is associated with the number of Rx payload Max Length Violation frames encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfIntervalFcsError 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.10
This counter is associated with the number of Frame Check Sequence errors encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfIntervalByteDestuffingViolation 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.11
This counter is associated with the number of Byte De-stuffing Violations encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfIntervalAdressMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.12
This counter is associated with the number of Address Mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfIntervalControlMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.13
This counter is associated with the number of Control mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfIntervalBelowMinThreshold 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.14
This counter is associated with the number of seconds that number of active VCs was below minimum threshold defined by vcGroupCnfgNoOfVCs, encountered by Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfLAPSCurrentTable 1.3.6.1.4.1.164.3.1.6.2.1.6.3
The Virtual Interface LAPS Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    VcGroupLAPSCurrentEntry

virtualIfLAPSCurrentEntry 1.3.6.1.4.1.164.3.1.6.2.1.6.3.1
An entry in the Virtual Interface LAPS Current table.
OBJECT-TYPE    
  VcGroupLAPSCurrentEntry  

virtualIfLAPSCurrentSapiMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.3.1.1
This counter is associated with the number of received SAPI field mismatch encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfLAPSIntervalTable 1.3.6.1.4.1.164.3.1.6.2.1.6.4
The Virtual Interface LAPS table.
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualIfLAPSIntervalEntry

virtualIfLAPSIntervalEntry 1.3.6.1.4.1.164.3.1.6.2.1.6.4.1
An entry in the Virtual Interface LAPS Interval table.
OBJECT-TYPE    
  VirtualIfLAPSIntervalEntry  

virtualIfLAPSIntervalSapiMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.4.1.1
This counter is associated with the number of received SAPI field mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfLAPFCurrentTable 1.3.6.1.4.1.164.3.1.6.2.1.6.5
The Virtual Interface LAPF Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualIfLAPFCurrentEntry

virtualIfLAPFCurrentEntry 1.3.6.1.4.1.164.3.1.6.2.1.6.5.1
An entry in the Virtual Interface LAPF Current table.
OBJECT-TYPE    
  VirtualIfLAPFCurrentEntry  

virtualIfLAPFCurrentNlpidMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.5.1.1
This counter is associated with the number of received NLPID field mismatch encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfLAPFCurrentOuiMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.5.1.2
This counter is associated with the number of received OUI field mismatch encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfLAPFCurrentPidMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.5.1.3
This counter is associated with the number of received PID field mismatch encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfLAPFCurrentDlciMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.5.1.4
This counter is associated with the number of received DLCI field mismatch encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfLAPFCurrentMacRxFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.5.1.5
This counter is associated with the number of frames received from LAN by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfLAPFCurrentMacTxFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.5.1.6
This counter is associated with the number of frames transmitted to LAN by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfLAPFIntervalTable 1.3.6.1.4.1.164.3.1.6.2.1.6.6
The Virtual Interface LAPF Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualIfLAPFIntervalEntry

virtualIfLAPFIntervalEntry 1.3.6.1.4.1.164.3.1.6.2.1.6.6.1
An entry in the Virtual Interface Interval table.
OBJECT-TYPE    
  VirtualIfLAPFIntervalEntry  

virtualIfLAPFIntervalNlpidMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.6.1.1
This counter is associated with the number of received NLPID field mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfLAPFIntervalOuiMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.6.1.2
This counter is associated with the number of received OUI field mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfLAPFIntervalPidMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.6.1.3
This counter is associated with the number of received PID field mismatch encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfLAPFIntervalDlciMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.6.1.4
This counter is associated with the number of received DLCI field mismatch by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfLAPFIntervalMacRxFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.6.1.5
This counter is associated with the number of frames received from LAN by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfLAPFIntervalMacTxFrames 1.3.6.1.4.1.164.3.1.6.2.1.6.6.1.6
This counter is associated with the number of frames transmitted to LAN encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfGFPCurrentTable 1.3.6.1.4.1.164.3.1.6.2.1.6.7
The Virtual Interface GFP Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualIfGFPCurrentEntry

virtualIfGFPCurrentEntry 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1
An entry in the Virtual Interface GFP Current table.
OBJECT-TYPE    
  VirtualIfGFPCurrentEntry  

virtualIfGFPCurrentIdleFrameError 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.1
This counter is associated with the number of received GFP IDLE frames that are detected to be in error, encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfGFPCurrentCHecSbError 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.2
This counter is associated with the number of received GFP frames that are detected to have single-bit errors in the Core header (i.e. cHEC field) only, encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfGFPCurrentPtiMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.3
This counter is associated with the number of rreceived GFP frames that are detected with a mismatch on the PTI field (i.e. value of PTI is not equal to Client Data or Management frame), encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfGFPCurrentExiMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.4
This counter is associated with the number of received GFP frames that are detected with a mismatch on the EXI field (i.e. value of EXI is not equal to NULL or LINEAR modes), encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfGFPCurrentUpiMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.5
This counter is associated with the number of received GFP frames that are detected with a mismatch on the UPI field (i.e. value of EXI is not equal to 00000001), encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfGFPCurrentTHecSbError 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.6
This counter is associated with the number of received GFP frames that are detected to only have single-bit errors in the Type header (i.e. tHEC field), encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfGFPCurrentTHecMbError 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.7
This counter is associated with the number of received GFP frames that are detected to only have multi-bit errors in the Type header (i.e. tHEC field), encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfGFPCurrentCidMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.8
This counter is associated with the number of received GFP frames that are detected to have a mismatch/unsupported value in the CID field only, encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfGFPCurrentEHecSbError 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.9
This counter is associated with the number of received GFP frames that are detected to only have single-bit errors in the Extension header (i.e. eHEC field), encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfGFPCurrentEHecMbError 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.10
This counter is associated with the number of received GFP frames that are detected to only have single-bit errors in the Extension header (i.e. eHEC field), encountered by a Virtual Interface in the current 15-minute interval.
OBJECT-TYPE    
  PerfCurrentCount  

virtualIfGFPIntervalTable 1.3.6.1.4.1.164.3.1.6.2.1.6.8
The Virtual Interface GFP Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualIfGFPIntervalEntry

virtualIfGFPIntervalEntry 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1
An entry in the Virtual Interface GFP Interval table.
OBJECT-TYPE    
  VirtualIfGFPIntervalEntry  

virtualIfGFPIntervalIdleFrameError 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1.1
This counter is associated with the number of received GFP IDLE frames that are detected to be in error, encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfGFPIntervalCHecSbError 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1.2
This counter is associated with the number of received GFP frames that are detected to have single-bit errors in the Core header (i.e. cHEC field) only, encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfGFPIntervalPtiMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1.3
This counter is associated with the number of rreceived GFP frames that are detected with a mismatch on the PTI field (i.e. value of PTI is not equal to Client Data or Management frame), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfGFPIntervalExiMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1.4
This counter is associated with the number of received GFP frames that are detected with a mismatch on the EXI field (i.e. value of EXI is not equal to NULL or LINEAR modes), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfGFPIntervalUpiMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1.5
This counter is associated with the number of received GFP frames that are detected with a mismatch on the UPI field (i.e. value of EXI is not equal to 00000001), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfGFPIntervalTHecSbError 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1.6
This counter is associated with the number of received GFP frames that are detected to only have single-bit errors in the Type header (i.e. tHEC field), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfGFPIntervalTHecMbError 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1.7
This counter is associated withthe number of received GFP frames that are detected to only have multi-bit errors in the Type header (i.e. tHEC field), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfGFPIntervalCidMismatch 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1.8
This counter is associated with the number of received GFP frames that are detected to have a mismatch/unsupported value in the CID field only, encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfGFPIntervalEHecSbError 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1.9
This counter is associated with the number of received GFP frames that are detected to only have single-bit errors in the Extension header (i.e. eHEC field), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

virtualIfGFPIntervalEHecMbError 1.3.6.1.4.1.164.3.1.6.2.1.6.8.1.10
This counter is associated with the the number of received GFP frames that are detected to only have multi-bit errors in the Extension header (i.e. eHEC field), encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  PerfIntervalCount  

prtSonetConfig 1.3.6.1.4.1.164.3.1.6.2.2
OBJECT IDENTIFIER    

prtSonetGen 1.3.6.1.4.1.164.3.1.6.2.2.1
OBJECT IDENTIFIER    

prtSonetGenTable 1.3.6.1.4.1.164.3.1.6.2.2.1.1
Sonet/SDH general port configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSonetGenEntry

prtSonetGenEntry 1.3.6.1.4.1.164.3.1.6.2.2.1.1.1
An entry in the Sonet/SDH general port configuration table.
OBJECT-TYPE    
  PrtSonetGenEntry  

prtSonetGenCnfgIdx 1.3.6.1.4.1.164.3.1.6.2.2.1.1.1.1
This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255).
OBJECT-TYPE    
  Integer32 1..255  

prtSonetGenIdx 1.3.6.1.4.1.164.3.1.6.2.2.1.1.1.2
This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex.
OBJECT-TYPE    
  Integer32  

prtSonetGenSdThreshold 1.3.6.1.4.1.164.3.1.6.2.2.1.1.1.3
SD=Signal Degraded Threshold. Units: [10E-]. The threshold is 10E-x relative to the frequency of the data flow. x=3, 4, 5, 6, 7, 8, 9. n3= 10E-3 n4= 10E-4 n5= 10E-5 n6= 10E-6 n7= 10E-7 n8= 10E-8 n9= 10E-9 .
OBJECT-TYPE    
  INTEGER notApplicable(1), n3(3), n4(4), n5(5), n6(6), n7(7), n8(8), n9(9)  

prtSonetGenEedThreshold 1.3.6.1.4.1.164.3.1.6.2.2.1.1.1.4
EED=Excessive Error Defect Threshold. Units: [10E-]. The threshold is 10E-x relative to the frequency of the data flow. x=3, 4, 5, 6, 7, 8, 9. n3= 10E-3 n4= 10E-4 n5= 10E-5 n6= 10E-6 n7= 10E-7 n8= 10E-8 n9= 10E-9 .
OBJECT-TYPE    
  INTEGER notApplicable(1), n3(3), n4(4), n5(5), n6(6), n7(7), n8(8), n9(9)  

prtSonetGenBerEnable 1.3.6.1.4.1.164.3.1.6.2.2.1.1.1.5
Controls the activation of the Line Ber (Bit Error Rate), means whether SD and EED threshold parameters will be enabled.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtSonetStm1 1.3.6.1.4.1.164.3.1.6.2.2.2
OBJECT IDENTIFIER    

prtSonetStm1Table 1.3.6.1.4.1.164.3.1.6.2.2.2.1
Sonet/SDH STM-1 port configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSonetStm1Entry

prtSonetStm1Entry 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1
An entry in the Sonet/SDH STM-1 port configuration table.
OBJECT-TYPE    
  PrtSonetStm1Entry  

prtSonetStm1CnfgIdx 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.1
This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255).
OBJECT-TYPE    
  Integer32 1..255  

prtSonetStm1Idx 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.2
This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex.
OBJECT-TYPE    
  Integer32  

prtSonetStm1ClockSrc 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.3
Clock Source of the STM-1 port. lbt = Loop Back Timing.
OBJECT-TYPE    
  INTEGER notApplicable(1), internal(2), lbt(3), systemClk(4)  

prtSonetStm1DccMode 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.4
DCC Mode. DCC=Data Communication Channel. d1ToD3 = D1-D3 bytes are used (RS=Regeneration Section). d4ToD12= D4-D12 bytes are used (MS=Multiplexing Section). d1.... d12 enable user to select single DCC byte
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), d1ToD3(3), d4ToD12(4), d1(5), d2(6), d3(7), d4(8), d5(9), d6(10), d7(11), d8(12), d9(13), d10(14), d11(15), d12(16)  

prtSonetStm1RoutingProt 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.5
Routing Protocol.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtSonetStm1MngProt 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.6
Management Protocol over DCC: Proprietary, PPP, Frame Relay, HDLC or LAPD over HDLC . ppp = according to STD-51 ( rfc1661/1662) pppType1= ppp without sendind ADD CONTROL overhead in Link Control Protocol (LCP) packets
OBJECT-TYPE    
  INTEGER notApplicable(1), proprietary(3), ppp(5), frameRelay(6), hdlc(7), lapdOverHdlc(8)  

prtSonetStm1OperationalMode 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.7
Operational Mode. linear - cannot be selected when there is Redundancy between the STM-1 ports.
OBJECT-TYPE    
  INTEGER notApplicable(1), terminal(2), linear(3), linearProtection(4)  

prtSonetStm1VoiceChannel 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.8
This parameter enable user to select whether voice channel will be transferred using E1 byte, E2 Byte, or not at all.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), e1Byte(3), e2Byte(4)  

prtSonetStm1OutputRate 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.9
This parameter indicates the output rate in cells/sec, which is supported per port.
OBJECT-TYPE    
  Integer32  

prtSonetStm1S1ProtocolClock 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.10
This parameter allows user to select whether to enable use of Remote Side Clock according to the Protocol passed on S1 Bit.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3), transparent(4)  

prtSonetStm1GatewayRingSubnetAddress 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.11
This parameter defines subnet for static routing, together with prtSonetStm1GatewayRingSubnetMask
OBJECT-TYPE    
  IpAddress  

prtSonetStm1GatewayRingSubnetMask 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.12
This parameter defines subnet for static routing, together with prtSonetStm1GatewayRingSubnetAddress
OBJECT-TYPE    
  IpAddress  

prtSonetStm1MngProtDeviationType 1.3.6.1.4.1.164.3.1.6.2.2.2.1.1.13
This parameter is used in conjunction with prtSonetStm1MngProt to define management protocol used & type of deviation (if exist) from standard. Standard = no deviation from standard protocol Type1 = PPP without sending Address and Control overhead in Link Control Protocol (LCP) packets
OBJECT-TYPE    
  INTEGER notApplicable(1), standard(2), type1(3)  

prtSonetVc 1.3.6.1.4.1.164.3.1.6.2.2.3
OBJECT IDENTIFIER    

prtSonetVcTable 1.3.6.1.4.1.164.3.1.6.2.2.3.1
Sonet/SDH VC port configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSonetVcEntry

prtSonetVcEntry 1.3.6.1.4.1.164.3.1.6.2.2.3.1.1
An entry in the Sonet/SDH VC port configuration table.
OBJECT-TYPE    
  PrtSonetVcEntry  

prtSonetVcCnfgIdx 1.3.6.1.4.1.164.3.1.6.2.2.3.1.1.1
This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255).
OBJECT-TYPE    
  Integer32 1..255  

prtSonetVcIdx 1.3.6.1.4.1.164.3.1.6.2.2.3.1.1.2
This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex.
OBJECT-TYPE    
  Integer32  

prtSonetVcJTxPathTraceEnable 1.3.6.1.4.1.164.3.1.6.2.2.3.1.1.3
Enable/Disable Transmitting Jy Path Trace. y=1, 2: J1 - for VC-4 layer J2 - for VC-12 layer.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtSonetVcJRxPathTraceEnable 1.3.6.1.4.1.164.3.1.6.2.2.3.1.1.4
Enable/Disable checking Jy Path Trace. y=1, 2: J1 - for VC-4 layer J2 - for VC-12 layer.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtSonetVcJPathTrace 1.3.6.1.4.1.164.3.1.6.2.2.3.1.1.5
Jy Path Trace. y=1, 2: J1 - for VC-4 layer J2 - for VC-12 layer. This object is applicable only if one of the previous 2 objects is 'enable'.
OBJECT-TYPE    
  DisplayString SIZE(0..62)  

prtSonetVcConnect 1.3.6.1.4.1.164.3.1.6.2.2.3.1.1.6
Connect VCn (n - 11,12,2,3,4) port (yes/no).
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtSonetVcSignalLabel 1.3.6.1.4.1.164.3.1.6.2.2.3.1.1.7
Signal Label. For VC-3: The SONET standard defines the C2 byte as the path signal label. The purpose of this byte is to communicate the payload type being encapsulated by the SONET Framing OverHead. It allows a single interface to transport multiple payload types simultaneously. For VC-12, VT-1.5: VT path overhead V5 byte allocates bits 5-7 for VT Path Signal Label, to indicate the content of the VT SPE. 000 Unequipped 001 Equipped : non-specific payload 010 Asynchronous mapping 011 Bit synchronous mapping (no longer valid for DS1) 100 Byte synchronous mapping 101 Unassigned 110 Unassigned 111 Unassigned Agents that do not support this feature will send SIZE 0.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

prtSonetTuTable 1.3.6.1.4.1.164.3.1.6.2.2.3.2
The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch).
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSonetTuEntry

prtSonetTuEntry 1.3.6.1.4.1.164.3.1.6.2.2.3.2.1
An entry in table.
OBJECT-TYPE    
  PrtSonetTuEntry  

prtSonetTuCnfgIdx 1.3.6.1.4.1.164.3.1.6.2.2.3.2.1.1
This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255).
OBJECT-TYPE    
  Integer32 1..255  

prtSonetTuPrtIdx 1.3.6.1.4.1.164.3.1.6.2.2.3.2.1.2
This object indicates a unique port or interface number. For port numbering, see product's spec. For some products, the numbering can equal ifIndex.
OBJECT-TYPE    
  Integer32  

prtSonetTuIdx 1.3.6.1.4.1.164.3.1.6.2.2.3.2.1.3
This object indicates a unique TU (Tributary Unit) within VC-4. The valid TUs are 1..63.
OBJECT-TYPE    
  Integer32  

prtSonetTuConPrtIdx 1.3.6.1.4.1.164.3.1.6.2.2.3.2.1.4
This object indicates the connected port, when prtSonetTuType=connect. For port numbering, see product's spec. For some products, the numbering can equal ifIndex. notApplicable - will be indicated as 100.
OBJECT-TYPE    
  Integer32  

prtSonetTuType 1.3.6.1.4.1.164.3.1.6.2.2.3.2.1.5
The type of TU (Tributary Unit). connect - connected to one of the E1 ports. bypass - bypassed to the other VC4 port. TUs that are not connected or bypassed, will not exist in this table.
OBJECT-TYPE    
  INTEGER connect(2), bypass(3)  

prtSonetTuMode 1.3.6.1.4.1.164.3.1.6.2.2.3.2.1.6
TU Mode of connection. addAndDrop - Add & Drop add - Add (TU receives from the E1 ports).
OBJECT-TYPE    
  INTEGER notApplicable(1), addAndDrop(2), add(3)  

prtSonetTuRowStatus 1.3.6.1.4.1.164.3.1.6.2.2.3.2.1.7
Creation/Deletion of rows in the table.
OBJECT-TYPE    
  RowStatus  

prtVcGroupCnfg 1.3.6.1.4.1.164.3.1.6.2.2.4
OBJECT IDENTIFIER    

vcGroupCnfgTable 1.3.6.1.4.1.164.3.1.6.2.2.4.1
The Virtual Concatenation Group configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    VcGroupCnfgEntry

vcGroupCnfgEntry 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1
An entry in the Virtual Concatenation Group configuration table.
OBJECT-TYPE    
  VcGroupCnfgEntry  

vcGroupCnfgIdx 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.1
This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255).
OBJECT-TYPE    
  Integer32 1..255  

vcGroupCnfgNumber 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.2
Virtual Concatenation Group Number. For FCD=155 up to eight groups are defined valid values are 1..8
OBJECT-TYPE    
  Integer32  

vcGroupCnfgRowStatus 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.3
Creation/Deletion of rows in the table.
OBJECT-TYPE    
  RowStatus  

vcGroupCnfgVcType 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.4
User may select type of SDH Virtual Containers (VC) (SONET Virtual Tributaries VT ) to be concatenated in this Virtual Concatenation Group. For SDH, values 2,3,4 are valid. For SONET, values 5 and 6 are valid.
OBJECT-TYPE    
  INTEGER notApplicable(1), vc12(2), vc3(3), vc4(4), vt1dot5(5), sts1(6)  

vcGroupCnfgNoOfVCs 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.5
User may select number of Virtual Containers (VC) (SONET Virtual Tributaries VT ) to be concatenated in this Virtual Concatenation Group. Valid range for this number depends on type VC selected by vcGroupCnfgVCType For SDH, up to 63 VC12, or up to 3 VC3, or 1 VC4 are valid For SONET, up to 84 VT1.5 without LCAS, or 64 VT1.5 under LCAS control. or up tp 3 STS-1/SPE, or 1 STS-3
OBJECT-TYPE    
  Integer32 0..84  

vcGroupCnfgLCAS 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.6
This object controls Link Capacity Adjustment Scheme (LCAS) activation.
OBJECT-TYPE    
  INTEGER notApplicable(1), lcasNotActive(2), lcasActive(3)  

vcGroupCnfgEncapsulation 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.7
This object enables user to select encapsulation method.
OBJECT-TYPE    
  INTEGER notApplicable(1), laps(2), lapf(3), gfp(4)  

vcGroupCnfgGroupIfIndex 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.8
The ifIndex assigend to this group.
OBJECT-TYPE    
  InterfaceIndex  

vcGroupCnfgRip2 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.9
This object controls RIP 2. User may select to send RIP 2 message over selected group or not
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

vcGroupCnfgGfpChId 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.10
Generic Framing Procedure (GFP) Channel ID, Valid only when vcGroupCnfgEncapsulation = gfp (4) Valid values are 0x00 - oxFF (hex)
OBJECT-TYPE    
  Integer32 0..255  

vcGroupCnfgK4 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.11
This object controls whether K4 byte (of Line Overhead) is used as an indication for virtual concatenation (VCAT). This object is applicable, when VCG includes only a single Virtual Container (VC) (or SONET VT)
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

vcGroupCnfgExSignalLabel 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.12
Extended Signal Label. Relevant only when vcGroupCnfgK4 = yes(3). Agents that do not support this feature will send SIZE 0.
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

vcGroupCnfgLcasMinNoOfVCs 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.13
Minimum number of VC's to declare alarm, in LCAS mode. Applicable only when LCAS is active (vcGroupCnfgLCAS =lcasActive) 1...63 for SDH, 1...84 for SONET 0= not applicable.
OBJECT-TYPE    
  Integer32 0..83  

vcGroupCnfgLcasStatus 1.3.6.1.4.1.164.3.1.6.2.2.4.1.1.14
This object summarize LCAS states of all VCs in VCG: belowMinNoOfVCs - Number of VCs in Norm state is less than the minimum number of VCs (indicated by vcGroupCnfgLcasMinNoOfVCs) withinRange - Number of VCs in Norm state is higher than the minimum number of VCs indicated by vcGroupCnfgLcasMinNoOfVCs) but is lower than Number of VCs mapped allNorm - Number of VCs in Norm state equals number of mapped VCs.
OBJECT-TYPE    
  INTEGER notApplicable(1), belowMinNoOfVCs(2), withinRange(3), allNorm(4)  

vcgGfpMuxCnfgTable 1.3.6.1.4.1.164.3.1.6.2.2.4.2
The Virtual Concatenation Group GFP Mux configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    VcgGfpMuxCnfgEntry

vcgGfpMuxCnfgEntry 1.3.6.1.4.1.164.3.1.6.2.2.4.2.1
An entry in the Virtual Concatenation Group GFP Mux configuration table.
OBJECT-TYPE    
  VcgGfpMuxCnfgEntry  

vcgGfpMuxCnfgIdx 1.3.6.1.4.1.164.3.1.6.2.2.4.2.1.1
This object indicates the Index of the configuration being accessed. Index of 255 relates to the Temporary (Scratch) coninguration. For products that support several configurations, Set can be performed only to the Temporary Config (=255).
OBJECT-TYPE    
  Integer32 1..255  

vcgGfpMuxCnfgMuxNumber 1.3.6.1.4.1.164.3.1.6.2.2.4.2.1.2
Virtual Concatenation Group GFP Mux Number. For FCD=155 up to 4 GFP muxes can be created.
OBJECT-TYPE    
  Integer32  

vcgGfpMuxCnfgRowStatus 1.3.6.1.4.1.164.3.1.6.2.2.4.2.1.3
Creation/Deletion of rows in the table.
OBJECT-TYPE    
  RowStatus  

vcgGfpMuxCnfgMuxName 1.3.6.1.4.1.164.3.1.6.2.2.4.2.1.4
Virtual Concatenation Group, GFP Mux name.
OBJECT-TYPE    
  SnmpAdminString  

vcgGfpMuxCnfgPrimeGroup 1.3.6.1.4.1.164.3.1.6.2.2.4.2.1.5
Index of Virtual Concatenation Group used as Primary for the GFP mux created for FCD 155 up to 8 Virtual Concatenation Group are defined: 1 -> Virtual Concatenation Group 1 2 -> Virtual Concatenation Group 2 3 -> Virtual Concatenation Group 3 4 -> Virtual Concatenation Group 4 5 -> Virtual Concatenation Group 5 6 -> Virtual Concatenation Group 6 7 -> Virtual Concatenation Group 7 8 -> Virtual Concatenation Group 8
OBJECT-TYPE    
  Integer32  

vcgGfpMuxCnfgGrpBwAlloc 1.3.6.1.4.1.164.3.1.6.2.2.4.2.1.6
This object indicates the allocated bandwidth (BW) to each Virtual Concatenation Group (VCG). Each nibble indicates BW percentage, in 12.5% steps, assigned to a group. For FCD-155, there may be 4 or 8 VCGs. When only 4 VCG exists, only two octets are used. In current GFP Mux,one VCG is identified as primary group by vcGfpMuxConfPrimeGroup. Other VCGs may be secondaries. VCG with allocated BW value of zero does not belong to the GFPmux defined by GFP Mux number. ---------------------------------------- | Octet 0 | Octet 1 | |Nibble 4 | Nibble 3| Nibble 2| Nibble 1| MSB | 7 6 5 4 | 3 2 1 0 | 7 6 5 4 | 3 2 1 0 | +-------------------+-------------------+ VCG1 VCG2 VCG 3 VCG4 ---------------------------------------- | Octet 3 | Octet 4 | |Nibble 4 | Nibble 3| Nibble 2| Nibble 1| | 7 6 5 4 | 3 2 1 0 | 7 6 5 4 | 3 2 1 0 | LSB +-------------------+-------------------+ VCG5 VCG6 VCG 7 VCG8 Nibble value - BW Percentage (0...7) (0 ...87.5%) 1 0001 12.5 % 2 0010 25% 3 0011 37.5 ..... 7 0111 87.5% at least one nibble must be greater that zero. Sum of alloacted BW must be 100%. Primary VCG BW must be greater than zero.
OBJECT-TYPE    
  OCTET STRING  

virtualIfConfiguration 1.3.6.1.4.1.164.3.1.6.2.2.5
OBJECT IDENTIFIER    

virtualIfGenTable 1.3.6.1.4.1.164.3.1.6.2.2.5.1
Sonet/SDH general port configuration table.
OBJECT-TYPE    
  SEQUENCE OF  
    VirtualIfGenEntry

virtualIfGenEntry 1.3.6.1.4.1.164.3.1.6.2.2.5.1.1
An entry in the Sonet/SDH general port configuration table.
OBJECT-TYPE    
  VirtualIfGenEntry  

virtualIfGenCnfgIdx 1.3.6.1.4.1.164.3.1.6.2.2.5.1.1.1
This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255).
OBJECT-TYPE    
  Integer32 1..255  

virtualIfGenIdx 1.3.6.1.4.1.164.3.1.6.2.2.5.1.1.2
This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex.
OBJECT-TYPE    
  Integer32  

virtualIfGenFrameFormat 1.3.6.1.4.1.164.3.1.6.2.2.5.1.1.3
The frame format. fcsEnabe = Frame will be sent with the FCS bits. fcsDisable = Frame will be sent without the FCS bits .
OBJECT-TYPE    
  INTEGER notApplicable(1), fcsEnable(2), fcsDisable(3)  

prtSonetXConnect 1.3.6.1.4.1.164.3.1.6.2.3
OBJECT IDENTIFIER    

prtSonetXConnectTable 1.3.6.1.4.1.164.3.1.6.2.3.1
The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch).
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSonetXConnectEntry

prtSonetXConnectEntry 1.3.6.1.4.1.164.3.1.6.2.3.1.1
An entry in table.
OBJECT-TYPE    
  PrtSonetXConnectEntry  

prtSonetXConnectCnfgIdx 1.3.6.1.4.1.164.3.1.6.2.3.1.1.1
This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255).
OBJECT-TYPE    
  Integer32 1..255  

prtSonetXConnectPrtIdx 1.3.6.1.4.1.164.3.1.6.2.3.1.1.2
This object indicates a unique port or interface number. For port numbering, see product's spec. For some products, the numbering can equal ifIndex.
OBJECT-TYPE    
  Integer32  

prtSonetXConnectConPrtIdx 1.3.6.1.4.1.164.3.1.6.2.3.1.1.3
This object indicates the connected port. For port numbering, see product's spec. For some products, the numbering can equal ifIndex. notApplicable - will be indicated as 255.
OBJECT-TYPE    
  Integer32  

prtSonetXConnectAUGIdx 1.3.6.1.4.1.164.3.1.6.2.3.1.1.4
This object indicates an AUG (Administrative Unit Group) within STM-N. The valid AUGs values are: 1 for STM-1 1...4 for STM-4, 1..16 for STM-16 and 1..64 for STM-64 (STM-64) 255 designates NA.
OBJECT-TYPE    
  Integer32  

prtSonetXConnectTUG3Idx 1.3.6.1.4.1.164.3.1.6.2.3.1.1.5
This object indicates a TUG-3 (Tributary Unit Group 3) within VC-4. The valid TUG3s are values are 1..3. and 255 which designates NA
OBJECT-TYPE    
  Integer32  

prtSonetXConnectTUG2Idx 1.3.6.1.4.1.164.3.1.6.2.3.1.1.6
This object indicates a TUG2 (Tributary Unit Group 2 ) within VC-3. The valid TUG2's values are 1..7 and 255 which designates NA
OBJECT-TYPE    
  Integer32  

prtSonetXConnectTUnIdx 1.3.6.1.4.1.164.3.1.6.2.3.1.1.7
This object indicates a TUn within TUG-2 or TUG-3 (Tributary Unit n, where n is 2, 12 or 11 within TUG-2, or 3 within TUG-3) valid values are 1 for TU-2 1 for TU-3 1..4 for TU-11 1..3 for TU-12 255 designates NA
OBJECT-TYPE    
  Integer32  

prtSonetXConnectRowStatus 1.3.6.1.4.1.164.3.1.6.2.3.1.1.8
Creation/Deletion of rows in the table.
OBJECT-TYPE    
  RowStatus  

prtSonetXConnectDirection 1.3.6.1.4.1.164.3.1.6.2.3.1.1.9
TU direction of connection. rx=Drop tx=Add both = Add & Drop
OBJECT-TYPE    
  INTEGER notApplicable(1), rx(2), tx(3), both(4)  

prtSonetXConnectTuNumber 1.3.6.1.4.1.164.3.1.6.2.3.1.1.10
This object indicates which TU is used in prtSonetXConnectTUnIdx
OBJECT-TYPE    
  INTEGER notApplicable(1), tu2(2), tu3(3), tu11(4), tu12(5)  

prtSonetStatus 1.3.6.1.4.1.164.3.1.6.2.4
OBJECT IDENTIFIER    

prtSonetVcStatTable 1.3.6.1.4.1.164.3.1.6.2.4.1
VC Status Table
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSonetVcStatEntry

prtSonetVcStatEntry 1.3.6.1.4.1.164.3.1.6.2.4.1.1
An entry in the VC status Table.
OBJECT-TYPE    
  PrtSonetVcStatEntry  

prtSonetVcRxJPathTrace 1.3.6.1.4.1.164.3.1.6.2.4.1.1.1
Jy Path Trace value received from network. y=1, 2: J1 - for VC-4 layer J2 - for VC-12 layer.
OBJECT-TYPE    
  SnmpAdminString SIZE(0..62)  

prtSonetVcRxSignalLabel 1.3.6.1.4.1.164.3.1.6.2.4.1.1.2
Signal Label received from network. For VC-3: The SONET standard defines the C2 byte as the path signal label. The purpose of this byte is to communicate the payload type being encapsulated by the SONET Framing OverHead. It allows a single interface to transport multiple payload types simultaneously. For VC-12, VT-1.5: VT path overhead V5 byte allocates bits 5-7 for VT Path Signal Label, to indicate the content of the VT SPE. 000 - Unequipped 001 - Equipped - non specific payload 010 - Asynchronous Mapping 011 - Bit Synchronous Mapping (no longer used) 100 - Byte Synchronous Mapping (TU11 or TU12) 101 - Extended Signal Label for Virtual Concatenation Applications (FCD-155 Default) 110 - Test Signal (0.181) (ITU) 111 - VC AIS (ITU)
OBJECT-TYPE    
  OCTET STRING SIZE(1)  

prtSonetVcLcasSourceState 1.3.6.1.4.1.164.3.1.6.2.4.1.1.3
Fixed - This is an indication that this end uses fixed bandwidth (non-LCAS mode) Add - This member is about to be added to the group Norm - Normal transmission. EOS - End of Sequence indication and Normal transmission. Idle - IDLE This member is not part of the group or about to be removed. Dnu - Do Not use - Do Not Use (the payload) the Sk side reported FAIL status.
OBJECT-TYPE    
  INTEGER notApplicable(1), fixed(2), add(3), norm(4), eos(5), idle(6), dnu(7)  

prtSonetVcLcasSinkState 1.3.6.1.4.1.164.3.1.6.2.4.1.1.4
Fixed - This is an indication that this end uses fixed bandwidth (non-LCAS mode) Add - This member is about to be added to the group Norm - Normal transmission. EOS - End of Sequence indication and Normal transmission. Idle - IDLE This member is not part of the group or about to be removed. Dnu - Do Not use - Do Not Use (the payload) the Sk side reported FAIL status.
OBJECT-TYPE    
  INTEGER notApplicable(1), fixed(2), add(3), norm(4), eos(5), idle(6), dnu(7)  

Defined Objects

PrtSonetMediumEntry  
SEQUENCE    
  Integer32 as prtSonetMediumTimeElapsed  
  Integer32 as prtSonetMediumValidIntervals  

PrtSectionLineCurrentEntry  
SEQUENCE    
  Gauge32 as prtSonetCurrentLOS  
  Gauge32 as prtSonetCurrentLOF  
  Gauge32 as prtSonetCurrentLineAIS  
  Gauge32 as prtSonetCurrentLineFERF  
  Gauge32 as prtSonetCurrentSectionBIP  
  Gauge32 as prtSonetCurrentLineBIP  
  Gauge32 as prtSonetCurrentLineFEBE  
  Gauge32 as prtSonetCurrentUAS  
  Gauge32 as prtSonetCurrentSES  
  Gauge32 as prtSonetCurrentES  
  OCTET STRING as prtSonetCurrentStatus  
  Gauge32 as prtSonetCurrentLSV  

PrtSectionLineIntervalEntry  
SEQUENCE    
  Integer32 as prtSonetLineIntervalNumber  
  Gauge32 as prtSonetIntervalLOS  
  Gauge32 as prtSonetIntervalLOF  
  Gauge32 as prtSonetIntervalLineAIS  
  Gauge32 as prtSonetIntervalLineFERF  
  Gauge32 as prtSonetIntervalSectionBIP  
  Gauge32 as prtSonetIntervalLineBIP  
  Gauge32 as prtSonetIntervalLineFEBE  
  Gauge32 as prtSonetIntervalUAS  
  Gauge32 as prtSonetIntervalSES  
  Gauge32 as prtSonetIntervalES  
  OCTET STRING as prtSonetIntervalStatus  
  Gauge32 as prtSonetIntervalLSV  

PrtPathCurrentEntry  
SEQUENCE    
  Gauge32 as prtSonetCurrentPathAIS  
  Gauge32 as prtSonetCurrentPathFERF  
  Gauge32 as prtSonetCurrentLOP  
  Gauge32 as prtSonetCurrentSLM  
  Gauge32 as prtSonetCurrentLOC  
  Gauge32 as prtSonetCurrentPathBIP  
  Gauge32 as prtSonetCurrentPathFEBE  

PrtPathIntervalEntry  
SEQUENCE    
  Integer32 as prtSonetPathIntervalNumber  
  Gauge32 as prtSonetIntervalPathAIS  
  Gauge32 as prtSonetIntervalPathFERF  
  Gauge32 as prtSonetIntervalLOP  
  Gauge32 as prtSonetIntervalSLM  
  Gauge32 as prtSonetIntervalLOC  
  Gauge32 as prtSonetIntervalPathBIP  
  Gauge32 as prtSonetIntervalPathFEBE  

VirtualIfCurrentEntry  
SEQUENCE    
  Integer32 as virtualIfCurrentMinActiveVC  
  Integer32 as virtualIfCurrentMaxActiveVC  
  Counter64 as virtualIfCurrentRxFrames  
  Counter64 as virtualIfCurrentTxFrames  
  PerfCurrentCount as virtualIfCurrentRxAbortFrames  
  PerfCurrentCount as virtualIfCurrentTxAbortFrames  
  PerfCurrentCount as virtualIfCurrentMinLengthViolation  
  PerfCurrentCount as virtualIfCurrentMaxLengthViolation  
  PerfCurrentCount as virtualIfCurrentFcsError  
  PerfCurrentCount as virtualIfCurrentByteDestuffingViolation  
  PerfCurrentCount as virtualIfCurrentAdressMismatch  
  PerfCurrentCount as virtualIfCurrentControlMismatch  
  Integer32 as virtualIfCurrentActiveVC  

VirtualIfIntervalEntry  
SEQUENCE    
  Integer32 as virtualIfIntervalNumber  
  Integer32 as virtualIfIntervalMinActiveVC  
  Integer32 as virtualIfIntervalMaxActiveVC  
  Counter64 as virtualIfIntervalRxFrames  
  Counter64 as virtualIfIntervalTxFrames  
  PerfIntervalCount as virtualIfIntervalRxAbortFrames  
  PerfIntervalCount as virtualIfIntervalTxAbortFrames  
  PerfIntervalCount as virtualIfIntervalMinLengthViolation  
  PerfIntervalCount as virtualIfIntervalMaxLengthViolation  
  PerfIntervalCount as virtualIfIntervalFcsError  
  PerfIntervalCount as virtualIfIntervalByteDestuffingViolation  
  PerfIntervalCount as virtualIfIntervalAdressMismatch  
  PerfIntervalCount as virtualIfIntervalControlMismatch  
  PerfIntervalCount as virtualIfIntervalBelowMinThreshold  

VcGroupLAPSCurrentEntry  
SEQUENCE    
  PerfCurrentCount as virtualIfLAPSCurrentSapiMismatch  

VirtualIfLAPSIntervalEntry  
SEQUENCE    
  PerfIntervalCount as virtualIfLAPSIntervalSapiMismatch  

VirtualIfLAPFCurrentEntry  
SEQUENCE    
  PerfCurrentCount as virtualIfLAPFCurrentNlpidMismatch  
  PerfCurrentCount as virtualIfLAPFCurrentOuiMismatch  
  PerfCurrentCount as virtualIfLAPFCurrentPidMismatch  
  PerfCurrentCount as virtualIfLAPFCurrentDlciMismatch  
  PerfCurrentCount as virtualIfLAPFCurrentMacRxFrames  
  PerfCurrentCount as virtualIfLAPFCurrentMacTxFrames  

VirtualIfLAPFIntervalEntry  
SEQUENCE    
  PerfIntervalCount as virtualIfLAPFIntervalNlpidMismatch  
  PerfIntervalCount as virtualIfLAPFIntervalOuiMismatch  
  PerfIntervalCount as virtualIfLAPFIntervalPidMismatch  
  PerfIntervalCount as virtualIfLAPFIntervalDlciMismatch  
  PerfIntervalCount as virtualIfLAPFIntervalMacRxFrames  
  PerfIntervalCount as virtualIfLAPFIntervalMacTxFrames  

VirtualIfGFPCurrentEntry  
SEQUENCE    
  PerfCurrentCount as virtualIfGFPCurrentIdleFrameError  
  PerfCurrentCount as virtualIfGFPCurrentCHecSbError  
  PerfCurrentCount as virtualIfGFPCurrentPtiMismatch  
  PerfCurrentCount as virtualIfGFPCurrentExiMismatch  
  PerfCurrentCount as virtualIfGFPCurrentUpiMismatch  
  PerfCurrentCount as virtualIfGFPCurrentTHecSbError  
  PerfCurrentCount as virtualIfGFPCurrentTHecMbError  
  PerfCurrentCount as virtualIfGFPCurrentCidMismatch  
  PerfCurrentCount as virtualIfGFPCurrentEHecSbError  
  PerfCurrentCount as virtualIfGFPCurrentEHecMbError  

VirtualIfGFPIntervalEntry  
SEQUENCE    
  PerfIntervalCount as virtualIfGFPIntervalIdleFrameError  
  PerfIntervalCount as virtualIfGFPIntervalCHecSbError  
  PerfIntervalCount as virtualIfGFPIntervalPtiMismatch  
  PerfIntervalCount as virtualIfGFPIntervalExiMismatch  
  PerfIntervalCount as virtualIfGFPIntervalUpiMismatch  
  PerfIntervalCount as virtualIfGFPIntervalTHecSbError  
  PerfIntervalCount as virtualIfGFPIntervalTHecMbError  
  PerfIntervalCount as virtualIfGFPIntervalCidMismatch  
  PerfIntervalCount as virtualIfGFPIntervalEHecSbError  
  PerfIntervalCount as virtualIfGFPIntervalEHecMbError  

PrtSonetGenEntry  
SEQUENCE    
  Integer32 as prtSonetGenCnfgIdx  
  Integer32 as prtSonetGenIdx  
  INTEGER as prtSonetGenSdThreshold  
  INTEGER as prtSonetGenEedThreshold  
  INTEGER as prtSonetGenBerEnable  

PrtSonetStm1Entry  
SEQUENCE    
  Integer32 as prtSonetStm1CnfgIdx  
  Integer32 as prtSonetStm1Idx  
  INTEGER as prtSonetStm1ClockSrc  
  INTEGER as prtSonetStm1DccMode  
  INTEGER as prtSonetStm1RoutingProt  
  INTEGER as prtSonetStm1MngProt  
  INTEGER as prtSonetStm1OperationalMode  
  INTEGER as prtSonetStm1VoiceChannel  
  Integer32 as prtSonetStm1OutputRate  
  INTEGER as prtSonetStm1S1ProtocolClock  
  IpAddress as prtSonetStm1GatewayRingSubnetAddress  
  IpAddress as prtSonetStm1GatewayRingSubnetMask  
  INTEGER as prtSonetStm1MngProtDeviationType  

PrtSonetVcEntry  
SEQUENCE    
  Integer32 as prtSonetVcCnfgIdx  
  Integer32 as prtSonetVcIdx  
  INTEGER as prtSonetVcJTxPathTraceEnable  
  INTEGER as prtSonetVcJRxPathTraceEnable  
  DisplayString as prtSonetVcJPathTrace  
  INTEGER as prtSonetVcConnect  
  OCTET STRING as prtSonetVcSignalLabel  

PrtSonetTuEntry  
SEQUENCE    
  Integer32 as prtSonetTuCnfgIdx  
  Integer32 as prtSonetTuPrtIdx  
  Integer32 as prtSonetTuIdx  
  Integer32 as prtSonetTuConPrtIdx  
  INTEGER as prtSonetTuType  
  INTEGER as prtSonetTuMode  
  RowStatus as prtSonetTuRowStatus  

PrtSonetXConnectEntry  
SEQUENCE    
  Integer32 as prtSonetXConnectCnfgIdx  
  Integer32 as prtSonetXConnectPrtIdx  
  Integer32 as prtSonetXConnectConPrtIdx  
  Integer32 as prtSonetXConnectAUGIdx  
  Integer32 as prtSonetXConnectTUG3Idx  
  Integer32 as prtSonetXConnectTUG2Idx  
  Integer32 as prtSonetXConnectTUnIdx  
  RowStatus as prtSonetXConnectRowStatus  
  INTEGER as prtSonetXConnectDirection  
  INTEGER as prtSonetXConnectTuNumber  

PrtSonetVcStatEntry  
SEQUENCE    
  SnmpAdminString as prtSonetVcRxJPathTrace  
  OCTET STRING as prtSonetVcRxSignalLabel  
  INTEGER as prtSonetVcLcasSourceState  
  INTEGER as prtSonetVcLcasSinkState  

VcGroupCnfgEntry  
SEQUENCE    
  Integer32 as vcGroupCnfgIdx  
  Integer32 as vcGroupCnfgNumber  
  RowStatus as vcGroupCnfgRowStatus  
  INTEGER as vcGroupCnfgVcType  
  Integer32 as vcGroupCnfgNoOfVCs  
  INTEGER as vcGroupCnfgLCAS  
  INTEGER as vcGroupCnfgEncapsulation  
  InterfaceIndex as vcGroupCnfgGroupIfIndex  
  INTEGER as vcGroupCnfgRip2  
  Integer32 as vcGroupCnfgGfpChId  
  INTEGER as vcGroupCnfgK4  
  OCTET STRING as vcGroupCnfgExSignalLabel  
  Integer32 as vcGroupCnfgLcasMinNoOfVCs  
  INTEGER as vcGroupCnfgLcasStatus  

VcgGfpMuxCnfgEntry  
SEQUENCE    
  Integer32 as vcgGfpMuxCnfgIdx  
  Integer32 as vcgGfpMuxCnfgMuxNumber  
  RowStatus as vcgGfpMuxCnfgRowStatus  
  SnmpAdminString as vcgGfpMuxCnfgMuxName  
  Integer32 as vcgGfpMuxCnfgPrimeGroup  
  OCTET STRING as vcgGfpMuxCnfgGrpBwAlloc  

VirtualIfGenEntry  
SEQUENCE    
  Integer32 as virtualIfGenCnfgIdx  
  Integer32 as virtualIfGenIdx  
  INTEGER as virtualIfGenFrameFormat