RFC1382-MIB

File: RFC1382-MIB.mib (117758 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 RFC1271-MIB RFC1253-MIB
RFC1381-MIB

Imported symbols

Counter Gauge TimeTicks
OBJECT-TYPE DisplayString transmission
TRAP-TYPE EntryStatus PositiveInteger
IfIndexType

Defined Objects

x25 1.3.6.1.2.1.10.5
OBJECT IDENTIFIER    

x25AdmnTable 1.3.6.1.2.1.10.5.1
This table contains the administratively set configuration parameters for an X.25 Packet Level Entity (PLE). Most of the objects in this table have corresponding objects in the x25OperTable. This table contains the values as last set by the administrator. The x25OperTable contains the values actually in use by an X.25 PLE. Changing an administrative value may or may not change a current operating value. The operating value may not change until the interface is restarted. Some implementations may change the values immediately upon changing the administrative table. All implementations are required to load the values from the administrative table when initializing a PLE.
OBJECT-TYPE    
  SEQUENCE OF  
    X25AdmnEntry

x25Restart 1.3.6.1.2.1.10.5.1
This trap means the X.25 PLE sent or received a restart packet. The restart that brings up the link should not send a x25Restart trap so the interface should send a linkUp trap. Sending this trap means the agent does not send a linkDown and linkUp trap.
TRAP-TYPE    
  x25OperIndex  

x25AdmnEntry 1.3.6.1.2.1.10.5.1.1
Entries of x25AdmnTable.
OBJECT-TYPE    
  X25AdmnEntry  

x25AdmnIndex 1.3.6.1.2.1.10.5.1.1.1
The ifIndex value for the X.25 Interface.
OBJECT-TYPE    
  IfIndexType  

x25AdmnInterfaceMode 1.3.6.1.2.1.10.5.1.1.2
Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the mode will be determined by XID negotiation.
OBJECT-TYPE    
  INTEGER dte(1), dce(2), dxe(3)  

x25AdmnMaxActiveCircuits 1.3.6.1.2.1.10.5.1.1.3
The maximum number of circuits this PLE can support; including PVCs.
OBJECT-TYPE    
  INTEGER 0..4096  

x25AdmnPacketSequencing 1.3.6.1.2.1.10.5.1.1.4
The modulus of the packet sequence number space.
OBJECT-TYPE    
  INTEGER modulo8(1), modulo128(2)  

x25AdmnRestartTimer 1.3.6.1.2.1.10.5.1.1.5
The T20 restart timer in milliseconds.
OBJECT-TYPE    
  PositiveInteger  

x25AdmnCallTimer 1.3.6.1.2.1.10.5.1.1.6
The T21 Call timer in milliseconds.
OBJECT-TYPE    
  PositiveInteger  

x25AdmnResetTimer 1.3.6.1.2.1.10.5.1.1.7
The T22 Reset timer in milliseconds.
OBJECT-TYPE    
  PositiveInteger  

x25AdmnClearTimer 1.3.6.1.2.1.10.5.1.1.8
The T23 Clear timer in milliseconds.
OBJECT-TYPE    
  PositiveInteger  

x25AdmnWindowTimer 1.3.6.1.2.1.10.5.1.1.9
The T24 window status transmission timer in milliseconds. A value of 2147483647 indicates no window timer in use.
OBJECT-TYPE    
  PositiveInteger  

x25AdmnDataRxmtTimer 1.3.6.1.2.1.10.5.1.1.10
The T25 data retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.
OBJECT-TYPE    
  PositiveInteger  

x25AdmnInterruptTimer 1.3.6.1.2.1.10.5.1.1.11
The T26 interrupt timer in milliseconds. A value of 2147483647 indicates no interrupt timer in use.
OBJECT-TYPE    
  PositiveInteger  

x25AdmnRejectTimer 1.3.6.1.2.1.10.5.1.1.12
The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.
OBJECT-TYPE    
  PositiveInteger  

x25AdmnRegistrationRequestTimer 1.3.6.1.2.1.10.5.1.1.13
The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.
OBJECT-TYPE    
  PositiveInteger  

x25AdmnMinimumRecallTimer 1.3.6.1.2.1.10.5.1.1.14
Minimum time interval between unsuccessful call attempts in milliseconds.
OBJECT-TYPE    
  PositiveInteger  

x25AdmnRestartCount 1.3.6.1.2.1.10.5.1.1.15
The R20 restart retransmission count.
OBJECT-TYPE    
  INTEGER 0..65535  

x25AdmnResetCount 1.3.6.1.2.1.10.5.1.1.16
The r22 Reset retransmission count.
OBJECT-TYPE    
  INTEGER 0..65535  

x25AdmnClearCount 1.3.6.1.2.1.10.5.1.1.17
The r23 Clear retransmission count.
OBJECT-TYPE    
  INTEGER 0..65535  

x25AdmnDataRxmtCount 1.3.6.1.2.1.10.5.1.1.18
The R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use.
OBJECT-TYPE    
  INTEGER 0..65535  

x25AdmnRejectCount 1.3.6.1.2.1.10.5.1.1.19
The R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use.
OBJECT-TYPE    
  INTEGER 0..65535  

x25AdmnRegistrationRequestCount 1.3.6.1.2.1.10.5.1.1.20
The R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use.
OBJECT-TYPE    
  INTEGER 0..65535  

x25AdmnNumberPVCs 1.3.6.1.2.1.10.5.1.1.21
The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.
OBJECT-TYPE    
  INTEGER 0..4096  

x25AdmnDefCallParamId 1.3.6.1.2.1.10.5.1.1.22
This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

x25AdmnLocalAddress 1.3.6.1.2.1.10.5.1.1.23
The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.
OBJECT-TYPE    
  X121Address  

x25AdmnProtocolVersionSupported 1.3.6.1.2.1.10.5.1.1.24
Identifies the version of the X.25 protocol this interface should support. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

x25OperTable 1.3.6.1.2.1.10.5.2
The operation parameters in use by the X.25 PLE.
OBJECT-TYPE    
  SEQUENCE OF  
    X25OperEntry

x25Reset 1.3.6.1.2.1.10.5.2
If the PLE sends or receives a reset, the agent should send an x25Reset trap.
TRAP-TYPE    
  x25CircuitIndex  
  x25CircuitChannel  

x25OperEntry 1.3.6.1.2.1.10.5.2.1
Entries of x25OperTable.
OBJECT-TYPE    
  X25OperEntry  

x25OperIndex 1.3.6.1.2.1.10.5.2.1.1
The ifIndex value for the X.25 interface.
OBJECT-TYPE    
  IfIndexType  

x25OperInterfaceMode 1.3.6.1.2.1.10.5.2.1.2
Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the role will be determined by XID negotiation at the Link Layer and that negotiation has not yet taken place.
OBJECT-TYPE    
  INTEGER dte(1), dce(2), dxe(3)  

x25OperMaxActiveCircuits 1.3.6.1.2.1.10.5.2.1.3
Maximum number of circuits this PLE can support.
OBJECT-TYPE    
  INTEGER 0..4096  

x25OperPacketSequencing 1.3.6.1.2.1.10.5.2.1.4
The modulus of the packet sequence number space.
OBJECT-TYPE    
  INTEGER modulo8(1), modulo128(2)  

x25OperRestartTimer 1.3.6.1.2.1.10.5.2.1.5
The T20 restart timer in milliseconds.
OBJECT-TYPE    
  PositiveInteger  

x25OperCallTimer 1.3.6.1.2.1.10.5.2.1.6
The T21 Call timer in milliseconds.
OBJECT-TYPE    
  PositiveInteger  

x25OperResetTimer 1.3.6.1.2.1.10.5.2.1.7
The T22 Reset timer in milliseconds.
OBJECT-TYPE    
  PositiveInteger  

x25OperClearTimer 1.3.6.1.2.1.10.5.2.1.8
The T23 Clear timer in milliseconds.
OBJECT-TYPE    
  PositiveInteger  

x25OperWindowTimer 1.3.6.1.2.1.10.5.2.1.9
The T24 window status transmission timer milliseconds. A value of 2147483647 indicates no window timer in use.
OBJECT-TYPE    
  PositiveInteger  

x25OperDataRxmtTimer 1.3.6.1.2.1.10.5.2.1.10
The T25 Data Retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.
OBJECT-TYPE    
  PositiveInteger  

x25OperInterruptTimer 1.3.6.1.2.1.10.5.2.1.11
The T26 Interrupt timer in milliseconds. A value of 2147483647 indicates interrupts are not being used.
OBJECT-TYPE    
  PositiveInteger  

x25OperRejectTimer 1.3.6.1.2.1.10.5.2.1.12
The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.
OBJECT-TYPE    
  PositiveInteger  

x25OperRegistrationRequestTimer 1.3.6.1.2.1.10.5.2.1.13
The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.
OBJECT-TYPE    
  PositiveInteger  

x25OperMinimumRecallTimer 1.3.6.1.2.1.10.5.2.1.14
Minimum time interval between unsuccessful call attempts in milliseconds.
OBJECT-TYPE    
  PositiveInteger  

x25OperRestartCount 1.3.6.1.2.1.10.5.2.1.15
The R20 restart retransmission count.
OBJECT-TYPE    
  INTEGER 0..65535  

x25OperResetCount 1.3.6.1.2.1.10.5.2.1.16
The r22 Reset retransmission count.
OBJECT-TYPE    
  INTEGER 0..65535  

x25OperClearCount 1.3.6.1.2.1.10.5.2.1.17
The r23 Clear retransmission count.
OBJECT-TYPE    
  INTEGER 0..65535  

x25OperDataRxmtCount 1.3.6.1.2.1.10.5.2.1.18
The R25 Data retransmission count. This value is undefined if the x25OperDataRxmtTimer indicates no timer in use.
OBJECT-TYPE    
  INTEGER 0..65535  

x25OperRejectCount 1.3.6.1.2.1.10.5.2.1.19
The R27 reject retransmission count. This value is undefined if the x25OperRejectTimer indicates no timer in use.
OBJECT-TYPE    
  INTEGER 0..65535  

x25OperRegistrationRequestCount 1.3.6.1.2.1.10.5.2.1.20
The R28 Registration retransmission Count. This value is undefined if the x25OperREgistrationRequestTimer indicates no timer in use.
OBJECT-TYPE    
  INTEGER 0..65535  

x25OperNumberPVCs 1.3.6.1.2.1.10.5.2.1.21
The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.
OBJECT-TYPE    
  INTEGER 0..4096  

x25OperDefCallParamId 1.3.6.1.2.1.10.5.2.1.22
This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable that contains the default call parameters for this PLE.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

x25OperLocalAddress 1.3.6.1.2.1.10.5.2.1.23
The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.
OBJECT-TYPE    
  X121Address  

x25OperDataLinkId 1.3.6.1.2.1.10.5.2.1.24
This identifies the instance of the index object in the first table of the most device specific MIB for the interface used by this PLE.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

x25OperProtocolVersionSupported 1.3.6.1.2.1.10.5.2.1.25
Identifies the version of the X.25 protocol this interface supports. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

x25StatTable 1.3.6.1.2.1.10.5.3
Statistics information about this X.25 PLE.
OBJECT-TYPE    
  SEQUENCE OF  
    X25StatEntry

x25StatEntry 1.3.6.1.2.1.10.5.3.1
Entries of the x25StatTable.
OBJECT-TYPE    
  X25StatEntry  

x25StatIndex 1.3.6.1.2.1.10.5.3.1.1
The ifIndex value for the X.25 interface.
OBJECT-TYPE    
  IfIndexType  

x25StatInCalls 1.3.6.1.2.1.10.5.3.1.2
The number of incoming calls received.
OBJECT-TYPE    
  Counter  

x25StatInCallRefusals 1.3.6.1.2.1.10.5.3.1.3
The number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast select.
OBJECT-TYPE    
  Counter  

x25StatInProviderInitiatedClears 1.3.6.1.2.1.10.5.3.1.4
The number of clear requests with a cause code other than DTE initiated.
OBJECT-TYPE    
  Counter  

x25StatInRemotelyInitiatedResets 1.3.6.1.2.1.10.5.3.1.5
The number of reset requests received with cause code DTE initiated.
OBJECT-TYPE    
  Counter  

x25StatInProviderInitiatedResets 1.3.6.1.2.1.10.5.3.1.6
The number of reset requests received with cause code other than DTE initiated.
OBJECT-TYPE    
  Counter  

x25StatInRestarts 1.3.6.1.2.1.10.5.3.1.7
The number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE interface. This only counts restarts received when the PLE already has an established connection with the remove PLE.
OBJECT-TYPE    
  Counter  

x25StatInDataPackets 1.3.6.1.2.1.10.5.3.1.8
The number of data packets received.
OBJECT-TYPE    
  Counter  

x25StatInAccusedOfProtocolErrors 1.3.6.1.2.1.10.5.3.1.9
The number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets.
OBJECT-TYPE    
  Counter  

x25StatInInterrupts 1.3.6.1.2.1.10.5.3.1.10
The number of interrupt packets received by the PLE or over the PVC/VC.
OBJECT-TYPE    
  Counter  

x25StatOutCallAttempts 1.3.6.1.2.1.10.5.3.1.11
The number of calls attempted.
OBJECT-TYPE    
  Counter  

x25StatOutCallFailures 1.3.6.1.2.1.10.5.3.1.12
The number of call attempts which failed. This includes calls that were cleared because of restrictive fast select.
OBJECT-TYPE    
  Counter  

x25StatOutInterrupts 1.3.6.1.2.1.10.5.3.1.13
The number of interrupt packets send by the PLE or over the PVC/VC.
OBJECT-TYPE    
  Counter  

x25StatOutDataPackets 1.3.6.1.2.1.10.5.3.1.14
The number of data packets sent by this PLE.
OBJECT-TYPE    
  Counter  

x25StatOutgoingCircuits 1.3.6.1.2.1.10.5.3.1.15
The number of active outgoing circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.
OBJECT-TYPE    
  Gauge  

x25StatIncomingCircuits 1.3.6.1.2.1.10.5.3.1.16
The number of active Incoming Circuits. This includes call indications received but not yet acknowledged. This does not count PVCs.
OBJECT-TYPE    
  Gauge  

x25StatTwowayCircuits 1.3.6.1.2.1.10.5.3.1.17
The number of active two-way Circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.
OBJECT-TYPE    
  Gauge  

x25StatRestartTimeouts 1.3.6.1.2.1.10.5.3.1.18
The number of times the T20 restart timer expired.
OBJECT-TYPE    
  Counter  

x25StatCallTimeouts 1.3.6.1.2.1.10.5.3.1.19
The number of times the T21 call timer expired.
OBJECT-TYPE    
  Counter  

x25StatResetTimeouts 1.3.6.1.2.1.10.5.3.1.20
The number of times the T22 reset timer expired.
OBJECT-TYPE    
  Counter  

x25StatClearTimeouts 1.3.6.1.2.1.10.5.3.1.21
The number of times the T23 clear timer expired.
OBJECT-TYPE    
  Counter  

x25StatDataRxmtTimeouts 1.3.6.1.2.1.10.5.3.1.22
The number of times the T25 data timer expired.
OBJECT-TYPE    
  Counter  

x25StatInterruptTimeouts 1.3.6.1.2.1.10.5.3.1.23
The number of times the T26 interrupt timer expired.
OBJECT-TYPE    
  Counter  

x25StatRetryCountExceededs 1.3.6.1.2.1.10.5.3.1.24
The number of times a retry counter was exhausted.
OBJECT-TYPE    
  Counter  

x25StatClearCountExceededs 1.3.6.1.2.1.10.5.3.1.25
The number of times the R23 clear count was exceeded.
OBJECT-TYPE    
  Counter  

x25ChannelTable 1.3.6.1.2.1.10.5.4
These objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interfaces has started may not be reflected in the operating PLE.
OBJECT-TYPE    
  SEQUENCE OF  
    X25ChannelEntry

x25ChannelEntry 1.3.6.1.2.1.10.5.4.1
Entries of x25ChannelTable.
OBJECT-TYPE    
  X25ChannelEntry  

x25ChannelIndex 1.3.6.1.2.1.10.5.4.1.1
The ifIndex value for the X.25 Interface.
OBJECT-TYPE    
  IfIndexType  

x25ChannelLIC 1.3.6.1.2.1.10.5.4.1.2
Lowest Incoming channel.
OBJECT-TYPE    
  INTEGER 0..4095  

x25ChannelHIC 1.3.6.1.2.1.10.5.4.1.3
Highest Incoming channel. A value of zero indicates no channels in this range.
OBJECT-TYPE    
  INTEGER 0..4095  

x25ChannelLTC 1.3.6.1.2.1.10.5.4.1.4
Lowest Two-way channel.
OBJECT-TYPE    
  INTEGER 0..4095  

x25ChannelHTC 1.3.6.1.2.1.10.5.4.1.5
Highest Two-way channel. A value of zero indicates no channels in this range.
OBJECT-TYPE    
  INTEGER 0..4095  

x25ChannelLOC 1.3.6.1.2.1.10.5.4.1.6
Lowest outgoing channel.
OBJECT-TYPE    
  INTEGER 0..4095  

x25ChannelHOC 1.3.6.1.2.1.10.5.4.1.7
Highest outgoing channel. A value of zero indicates no channels in this range.
OBJECT-TYPE    
  INTEGER 0..4095  

x25CircuitTable 1.3.6.1.2.1.10.5.5
These objects contain general information about a specific circuit of an X.25 PLE.
OBJECT-TYPE    
  SEQUENCE OF  
    X25CircuitEntry

x25CircuitEntry 1.3.6.1.2.1.10.5.5.1
Entries of x25CircuitTable.
OBJECT-TYPE    
  X25CircuitEntry  

x25CircuitIndex 1.3.6.1.2.1.10.5.5.1.1
The ifIndex value for the X.25 Interface.
OBJECT-TYPE    
  IfIndexType  

x25CircuitChannel 1.3.6.1.2.1.10.5.5.1.2
The channel number for this circuit.
OBJECT-TYPE    
  INTEGER 0..4095  

x25CircuitStatus 1.3.6.1.2.1.10.5.5.1.3
This object reports the current status of the circuit. An existing instance of this object can only be set to startClear, startPvcResetting, or invalid. An instance with the value calling or open can only be set to startClear and that action will start clearing the circuit. An instance with the value PVC can only be set to startPvcResetting or invalid and that action resets the PVC or deletes the circuit respectively. The values startClear or startPvcResetting will never be returned by an agent. An attempt to set the status of an existing instance to a value other than one of these values will result in an error. A non-existing instance can be set to PVC to create a PVC if the implementation supports dynamic creation of PVCs. Some implementations may only allow creation and deletion of PVCs if the interface is down. Since the instance identifier will supply the PLE index and the channel number, setting this object alone supplies sufficient information to create the instance. All the DEFVAL clauses for the other objects of this table are appropriate for creating a PVC; PLEs creating entries for placed or accepted calls will use values appropriate for the call rather than the value of the DEFVAL clause. Two managers trying to create the same PVC can determine from the return code which manager succeeded and which failed (the failing manager fails because it can not set a value of PVC for an existing object). An entry in the closed or invalid state may be deleted or reused at the agent's convence. If the entry is kept in the closed state, the values of the parameters associated with the entry must be correct. Closed implies the values in the circuit table are correct. The value of invalid indicates the other values in the table are invalid. Many agents may never return a value of invalid because they dynamically allocate and free unused table entries. An agent for a statically configured systems can return invalid to indicate the entry has not yet been used so the counters contain no information.
OBJECT-TYPE    
  INTEGER invalid(1), closed(2), calling(3), open(4), clearing(5), pvc(6), pvcResetting(7), startClear(8), startPvcResetting(9), other(10)  

x25CircuitEstablishTime 1.3.6.1.2.1.10.5.5.1.4
The value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs, this is the time the call indication was received. For PVCs this is the time the PVC was able to pass data to a higher layer entity without loss of data.
OBJECT-TYPE    
  TimeTicks  

x25CircuitDirection 1.3.6.1.2.1.10.5.5.1.5
The direction of the call that established this circuit.
OBJECT-TYPE    
  INTEGER incoming(1), outgoing(2), pvc(3)  

x25CircuitInOctets 1.3.6.1.2.1.10.5.5.1.6
The number of octets of user data delivered to upper layer.
OBJECT-TYPE    
  Counter  

x25CircuitInPdus 1.3.6.1.2.1.10.5.5.1.7
The number of PDUs received for this circuit.
OBJECT-TYPE    
  Counter  

x25CircuitInRemotelyInitiatedResets 1.3.6.1.2.1.10.5.5.1.8
The number of Resets received for this circuit with cause code of DTE initiated.
OBJECT-TYPE    
  Counter  

x25CircuitInProviderInitiatedResets 1.3.6.1.2.1.10.5.5.1.9
The number of Resets received for this circuit with cause code other than DTE initiated.
OBJECT-TYPE    
  Counter  

x25CircuitInInterrupts 1.3.6.1.2.1.10.5.5.1.10
The number of interrupt packets received for this circuit.
OBJECT-TYPE    
  Counter  

x25CircuitOutOctets 1.3.6.1.2.1.10.5.5.1.11
The number of octets of user data sent for this circuit.
OBJECT-TYPE    
  Counter  

x25CircuitOutPdus 1.3.6.1.2.1.10.5.5.1.12
The number of PDUs sent for this circuit.
OBJECT-TYPE    
  Counter  

x25CircuitOutInterrupts 1.3.6.1.2.1.10.5.5.1.13
The number of interrupt packets sent on this circuit.
OBJECT-TYPE    
  Counter  

x25CircuitDataRetransmissionTimeouts 1.3.6.1.2.1.10.5.5.1.14
The number of times the T25 data retransmission timer expired for this circuit.
OBJECT-TYPE    
  Counter  

x25CircuitResetTimeouts 1.3.6.1.2.1.10.5.5.1.15
The number of times the T22 reset timer expired for this circuit.
OBJECT-TYPE    
  Counter  

x25CircuitInterruptTimeouts 1.3.6.1.2.1.10.5.5.1.16
The number of times the T26 Interrupt timer expired for this circuit.
OBJECT-TYPE    
  Counter  

x25CircuitCallParamId 1.3.6.1.2.1.10.5.5.1.17
This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The entry referenced must contain the values that are currently in use by the circuit rather than proposed values. A value of NULL indicates the circuit is a PVC or is using all the default parameters.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

x25CircuitCalledDteAddress 1.3.6.1.2.1.10.5.5.1.18
For incoming calls, this is the called address from the call indication packet. For outgoing calls, this is the called address from the call confirmation packet. This will be zero length for PVCs.
OBJECT-TYPE    
  X121Address  

x25CircuitCallingDteAddress 1.3.6.1.2.1.10.5.5.1.19
For incoming calls, this is the calling address from the call indication packet. For outgoing calls, this is the calling address from the call confirmation packet. This will be zero length for PVCs.
OBJECT-TYPE    
  X121Address  

x25CircuitOriginallyCalledAddress 1.3.6.1.2.1.10.5.5.1.20
For incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it will be called address from the call indication packet. For outgoing calls, this is the address from the call request packet. This will be zero length for PVCs.
OBJECT-TYPE    
  X121Address  

x25CircuitDescr 1.3.6.1.2.1.10.5.5.1.21
A descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of the circuit. The agent may return the process identifier and user name for the process using the circuit. Alternative the agent may return the name of the configuration entry that caused a bridge to establish the circuit. A zero length value indicates the agent doesn't have any additional information.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

x25ClearedCircuitEntriesRequested 1.3.6.1.2.1.10.5.6
The requested number of entries for the agent to keep in the x25ClearedCircuit table.
OBJECT-TYPE    
  PositiveInteger  

x25ClearedCircuitEntriesGranted 1.3.6.1.2.1.10.5.7
The actual number of entries the agent will keep in the x25ClearedCircuit Table.
OBJECT-TYPE    
  PositiveInteger  

x25ClearedCircuitTable 1.3.6.1.2.1.10.5.8
A table of entries about closed circuits. Entries must be made in this table whenever circuits are closed and the close request or close indication packet contains a clearing cause other than DTE Originated or a Diagnostic code field other than Higher Layer Initiated disconnection-normal. An agent may optionally make entries for normal closes (to record closing facilities or other information). Agents will delete the oldest entry in the table when adding a new entry would exceed agent resources. Agents are required to keep the last entry put in the table and may keep more entries. The object x25OperClearEntriesGranted returns the maximum number of entries kept in the table.
OBJECT-TYPE    
  SEQUENCE OF  
    X25ClearedCircuitEntry

x25ClearedCircuitEntry 1.3.6.1.2.1.10.5.8.1
Information about a cleared circuit.
OBJECT-TYPE    
  X25ClearedCircuitEntry  

x25ClearedCircuitIndex 1.3.6.1.2.1.10.5.8.1.1
An index that uniquely distinguishes one entry in the clearedCircuitTable from another. This index will start at 2147483647 and will decrease by one for each new entry added to the table. Upon reaching one, the index will reset to 2147483647. Because the index starts at 2147483647 and decreases, a manager may do a getnext on entry zero and obtain the most recent entry. When the index has the value of 1, the next entry will delete all entries in the table and that entry will be numbered 2147483647.
OBJECT-TYPE    
  PositiveInteger  

x25ClearedCircuitPleIndex 1.3.6.1.2.1.10.5.8.1.2
The value of ifIndex for the PLE which cleared the circuit that created the entry.
OBJECT-TYPE    
  IfIndexType  

x25ClearedCircuitTimeEstablished 1.3.6.1.2.1.10.5.8.1.3
The value of sysUpTime when the circuit was established. This will be the same value that was in the x25CircuitEstablishTime for the circuit.
OBJECT-TYPE    
  TimeTicks  

x25ClearedCircuitTimeCleared 1.3.6.1.2.1.10.5.8.1.4
The value of sysUpTime when the circuit was cleared. For locally initiated clears, this will be the time when the clear confirmation was received. For remotely initiated clears, this will be the time when the clear indication was received.
OBJECT-TYPE    
  TimeTicks  

x25ClearedCircuitChannel 1.3.6.1.2.1.10.5.8.1.5
The channel number for the circuit that was cleared.
OBJECT-TYPE    
  INTEGER 0..4095  

x25ClearedCircuitClearingCause 1.3.6.1.2.1.10.5.8.1.6
The Clearing Cause from the clear request or clear indication packet that cleared the circuit.
OBJECT-TYPE    
  INTEGER 0..255  

x25ClearedCircuitDiagnosticCode 1.3.6.1.2.1.10.5.8.1.7
The Diagnostic Code from the clear request or clear indication packet that cleared the circuit.
OBJECT-TYPE    
  INTEGER 0..255  

x25ClearedCircuitInPdus 1.3.6.1.2.1.10.5.8.1.8
The number of PDUs received on the circuit.
OBJECT-TYPE    
  Counter  

x25ClearedCircuitOutPdus 1.3.6.1.2.1.10.5.8.1.9
The number of PDUs transmitted on the circuit.
OBJECT-TYPE    
  Counter  

x25ClearedCircuitCalledAddress 1.3.6.1.2.1.10.5.8.1.10
The called address from the cleared circuit.
OBJECT-TYPE    
  X121Address  

x25ClearedCircuitCallingAddress 1.3.6.1.2.1.10.5.8.1.11
The calling address from the cleared circuit.
OBJECT-TYPE    
  X121Address  

x25ClearedCircuitClearFacilities 1.3.6.1.2.1.10.5.8.1.12
The facilities field from the clear request or clear indication packet that cleared the circuit. A size of zero indicates no facilities were present.
OBJECT-TYPE    
  OCTET STRING SIZE(0..109)  

x25CallParmTable 1.3.6.1.2.1.10.5.9
These objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of these tables for the entire system. The indexes for the entries are independent of any PLE or any circuit. Other tables reference entries in this table. Entries in this table can be used for default PLE parameters, for parameters to use to place/answer a call, for the parameters currently in use for a circuit, or parameters that were used by a circuit. The number of references to a given set of parameters can be found in the x25CallParmRefCount object sharing the same instance identifier with the parameters. The value of this reference count also affects the access of the objects in this table. An object in this table with the same instance identifier as the instance identifier of an x25CallParmRefCount must be consider associated with that reference count. An object with an associated reference count of zero can be written (if its ACCESS clause allows it). An object with an associated reference count greater than zero can not be written (regardless of the ACCESS clause). This ensures that a set of call parameters being referenced from another table can not be modified or changed in a ways inappropriate for continued use by that table.
OBJECT-TYPE    
  SEQUENCE OF  
    X25CallParmEntry

x25CallParmEntry 1.3.6.1.2.1.10.5.9.1
Entries of x25CallParmTable.
OBJECT-TYPE    
  X25CallParmEntry  

x25CallParmIndex 1.3.6.1.2.1.10.5.9.1.1
A value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossible to know which other objects in the MIB reference entries in the table by looking at this table. Because of this, changes to parameters must be accomplished by creating a new entry in this table and then changing the referencing table to identify the new entry. Note that an agent will only use the values in this table when another table is changed to reference those values. The number of other tables that reference an index object in this table can be found in x25CallParmRefCount. The value of the reference count will affect the writability of the objects as explained above. Entries in this table which have a reference count of zero maybe deleted at the convence of the agent. Care should be taken by the agent to give the NMS sufficient time to create a reference to newly created entries. Should a Management Station not find a free index with which to create a new entry, it may feel free to delete entries with a reference count of zero. However in doing so the Management Station much realize it may impact other Management Stations.
OBJECT-TYPE    
  PositiveInteger  

x25CallParmStatus 1.3.6.1.2.1.10.5.9.1.2
The status of this call parameter entry. See RFC 1271 for details of usage.
OBJECT-TYPE    
  EntryStatus  

x25CallParmRefCount 1.3.6.1.2.1.10.5.9.1.3
The number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value of, and will return a value of, the index for this set of call parameters. Examples of such objects are the x25AdmnDefCallParamId, x25OperDataLinkId, or x25AdmnDefCallParamId objects defined above.
OBJECT-TYPE    
  PositiveInteger  

x25CallParmInPacketSize 1.3.6.1.2.1.10.5.9.1.4
The maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a default size of 128.
OBJECT-TYPE    
  INTEGER 0..4096  

x25CallParmOutPacketSize 1.3.6.1.2.1.10.5.9.1.5
The maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use a default size of 128.
OBJECT-TYPE    
  INTEGER 0..4096  

x25CallParmInWindowSize 1.3.6.1.2.1.10.5.9.1.6
The receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.
OBJECT-TYPE    
  INTEGER 0..127  

x25CallParmOutWindowSize 1.3.6.1.2.1.10.5.9.1.7
The transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.
OBJECT-TYPE    
  INTEGER 0..127  

x25CallParmAcceptReverseCharging 1.3.6.1.2.1.10.5.9.1.8
An enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of neverAccept is only used for the PLE default and indicates the PLE will never accept reverse charging. A value of default for a PLE default means refuse.
OBJECT-TYPE    
  INTEGER default(1), accept(2), refuse(3), neverAccept(4)  

x25CallParmProposeReverseCharging 1.3.6.1.2.1.10.5.9.1.9
An enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default for the PLE default means use local.
OBJECT-TYPE    
  INTEGER default(1), reverse(2), local(3)  

x25CallParmFastSelect 1.3.6.1.2.1.10.5.9.1.10
Expresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means noFastSelect. A value of noFastSelect or noRestrictedFastResponse indicates a circuit may not use fast select or restricted fast response.
OBJECT-TYPE    
  INTEGER default(1), notSpecified(2), fastSelect(3), restrictedFastResponse(4), noFastSelect(5), noRestrictedFastResponse(6)  

x25CallParmInThruPutClasSize 1.3.6.1.2.1.10.5.9.1.11
The incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone. A value of tcNone means do not negotiate throughtput class.
OBJECT-TYPE    
  INTEGER tcReserved1(1), tcReserved2(2), tc75(3), tc150(4), tc300(5), tc600(6), tc1200(7), tc2400(8), tc4800(9), tc9600(10), tc19200(11), tc48000(12), tc64000(13), tcReserved14(14), tcReserved15(15), tcReserved0(16), tcNone(17), tcDefault(18)  

x25CallParmOutThruPutClasSize 1.3.6.1.2.1.10.5.9.1.12
The outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tcNone. A value of tcNone means do not negotiate throughtput class.
OBJECT-TYPE    
  INTEGER tcReserved1(1), tcReserved2(2), tc75(3), tc150(4), tc300(5), tc600(6), tc1200(7), tc2400(8), tc4800(9), tc9600(10), tc19200(11), tc48000(12), tc64000(13), tcReserved14(14), tcReserved15(15), tcReserved0(16), tcNone(17), tcDefault(18)  

x25CallParmCug 1.3.6.1.2.1.10.5.9.1.13
The Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility requested. A string length of three containing the characters DEF for a circuit means use the PLE default, (the PLE default parameter may not reference an entry of DEF.)
OBJECT-TYPE    
  DisplayString SIZE(0..4)  

x25CallParmCugoa 1.3.6.1.2.1.10.5.9.1.14
The Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameters may not reference an entry of DEF). A zero length string indicates no facility requested.
OBJECT-TYPE    
  DisplayString SIZE(0..4)  

x25CallParmBcug 1.3.6.1.2.1.10.5.9.1.15
The Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameter may not reference an entry of DEF). A zero length string indicates no facility requested.
OBJECT-TYPE    
  DisplayString SIZE(0..3)  

x25CallParmNui 1.3.6.1.2.1.10.5.9.1.16
The Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero length string indicates no facility requested. This value is ignored for the PLE default parameters entry.
OBJECT-TYPE    
  OCTET STRING SIZE(0..108)  

x25CallParmChargingInfo 1.3.6.1.2.1.10.5.9.1.17
The charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use noFacility. The value of noFacility means do not include a facility.
OBJECT-TYPE    
  INTEGER default(1), noFacility(2), noChargingInfo(3), chargingInfo(4)  

x25CallParmRpoa 1.3.6.1.2.1.10.5.9.1.18
The RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 characters DEF for a circuit specifies use of the PLE default (the entry for the PLE default may not contain DEF). A zero length string indicates no facility requested.
OBJECT-TYPE    
  DisplayString SIZE(0..108)  

x25CallParmTrnstDly 1.3.6.1.2.1.10.5.9.1.19
The Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (the PLE default parameters entry may not use the value 65537). The value 65535 may only be used to indicate the value in use by a circuit.
OBJECT-TYPE    
  INTEGER 0..65537  

x25CallParmCallingExt 1.3.6.1.2.1.10.5.9.1.20
The Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

x25CallParmCalledExt 1.3.6.1.2.1.10.5.9.1.21
The Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested.
OBJECT-TYPE    
  DisplayString SIZE(0..40)  

x25CallParmInMinThuPutCls 1.3.6.1.2.1.10.5.9.1.22
The minimum input throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested.
OBJECT-TYPE    
  INTEGER 0..17  

x25CallParmOutMinThuPutCls 1.3.6.1.2.1.10.5.9.1.23
The minimum output throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested.
OBJECT-TYPE    
  INTEGER 0..17  

x25CallParmEndTrnsDly 1.3.6.1.2.1.10.5.9.1.24
The End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An octet string of length 3 containing the three character DEF for a circuit means use the PLE default (the entry for the PLE default can not contain the characters DEF). A zero length string indicates no facility requested.
OBJECT-TYPE    
  OCTET STRING SIZE(0..6)  

x25CallParmPriority 1.3.6.1.2.1.10.5.9.1.25
The priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requested. The entry for the PLE default parameters must be zero length.
OBJECT-TYPE    
  OCTET STRING SIZE(0..6)  

x25CallParmProtection 1.3.6.1.2.1.10.5.9.1.26
A string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the packet by the agent. The agent will supply the length field and the length octet is not contained in this string. An string containing the 3 characters DEF for a circuit means use the PLE default (the entry for the PLE default parameters may not use the value DEF). A zero length string mean no facility requested.
OBJECT-TYPE    
  DisplayString SIZE(0..108)  

x25CallParmExptData 1.3.6.1.2.1.10.5.9.1.27
The Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not have the value default.
OBJECT-TYPE    
  INTEGER default(1), noExpeditedData(2), expeditedData(3)  

x25CallParmUserData 1.3.6.1.2.1.10.5.9.1.28
The call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call user data defined, the data from the circuit call parameters will be used. If only the PLE has data defined, the PLE entry will be used. If neither the circuit call parameters or the PLE default entry has a value, no call user data will be sent.
OBJECT-TYPE    
  OCTET STRING SIZE(0..128)  

x25CallParmCallingNetworkFacilities 1.3.6.1.2.1.10.5.9.1.29
The calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities.
OBJECT-TYPE    
  OCTET STRING SIZE(0..108)  

x25CallParmCalledNetworkFacilities 1.3.6.1.2.1.10.5.9.1.30
The called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities.
OBJECT-TYPE    
  OCTET STRING SIZE(0..108)  

x25ProtocolVersion 1.3.6.1.2.1.10.5.10
OBJECT IDENTIFIER    

x25protocolCcittV1976 1.3.6.1.2.1.10.5.10.1
OBJECT IDENTIFIER    

x25protocolCcittV1980 1.3.6.1.2.1.10.5.10.2
OBJECT IDENTIFIER    

x25protocolCcittV1984 1.3.6.1.2.1.10.5.10.3
OBJECT IDENTIFIER    

x25protocolCcittV1988 1.3.6.1.2.1.10.5.10.4
OBJECT IDENTIFIER    

x25protocolIso8208V1987 1.3.6.1.2.1.10.5.10.5
OBJECT IDENTIFIER    

x25protocolIso8208V1989 1.3.6.1.2.1.10.5.10.6
OBJECT IDENTIFIER    

Defined Objects

X121Address  
OCTET STRING SIZE(0..17)    

X25AdmnEntry  
SEQUENCE    
  IfIndexType as x25AdmnIndex  
  INTEGER as x25AdmnInterfaceMode  
  INTEGER as x25AdmnMaxActiveCircuits  
  INTEGER as x25AdmnPacketSequencing  
  PositiveInteger as x25AdmnRestartTimer  
  PositiveInteger as x25AdmnCallTimer  
  PositiveInteger as x25AdmnResetTimer  
  PositiveInteger as x25AdmnClearTimer  
  PositiveInteger as x25AdmnWindowTimer  
  PositiveInteger as x25AdmnDataRxmtTimer  
  PositiveInteger as x25AdmnInterruptTimer  
  PositiveInteger as x25AdmnRejectTimer  
  PositiveInteger as x25AdmnRegistrationRequestTimer  
  PositiveInteger as x25AdmnMinimumRecallTimer  
  INTEGER as x25AdmnRestartCount  
  INTEGER as x25AdmnResetCount  
  INTEGER as x25AdmnClearCount  
  INTEGER as x25AdmnDataRxmtCount  
  INTEGER as x25AdmnRejectCount  
  INTEGER as x25AdmnRegistrationRequestCount  
  INTEGER as x25AdmnNumberPVCs  
  OBJECT IDENTIFIER as x25AdmnDefCallParamId  
  X121Address as x25AdmnLocalAddress  
  OBJECT IDENTIFIER as x25AdmnProtocolVersionSupported  

X25OperEntry  
SEQUENCE    
  IfIndexType as x25OperIndex  
  INTEGER as x25OperInterfaceMode  
  INTEGER as x25OperMaxActiveCircuits  
  INTEGER as x25OperPacketSequencing  
  PositiveInteger as x25OperRestartTimer  
  PositiveInteger as x25OperCallTimer  
  PositiveInteger as x25OperResetTimer  
  PositiveInteger as x25OperClearTimer  
  PositiveInteger as x25OperWindowTimer  
  PositiveInteger as x25OperDataRxmtTimer  
  PositiveInteger as x25OperInterruptTimer  
  PositiveInteger as x25OperRejectTimer  
  PositiveInteger as x25OperRegistrationRequestTimer  
  PositiveInteger as x25OperMinimumRecallTimer  
  INTEGER as x25OperRestartCount  
  INTEGER as x25OperResetCount  
  INTEGER as x25OperClearCount  
  INTEGER as x25OperDataRxmtCount  
  INTEGER as x25OperRejectCount  
  INTEGER as x25OperRegistrationRequestCount  
  INTEGER as x25OperNumberPVCs  
  OBJECT IDENTIFIER as x25OperDefCallParamId  
  X121Address as x25OperLocalAddress  
  OBJECT IDENTIFIER as x25OperDataLinkId  
  OBJECT IDENTIFIER as x25OperProtocolVersionSupported  

X25StatEntry  
SEQUENCE    
  IfIndexType as x25StatIndex  
  Counter as x25StatInCalls  
  Counter as x25StatInCallRefusals  
  Counter as x25StatInProviderInitiatedClears  
  Counter as x25StatInRemotelyInitiatedResets  
  Counter as x25StatInProviderInitiatedResets  
  Counter as x25StatInRestarts  
  Counter as x25StatInDataPackets  
  Counter as x25StatInAccusedOfProtocolErrors  
  Counter as x25StatInInterrupts  
  Counter as x25StatOutCallAttempts  
  Counter as x25StatOutCallFailures  
  Counter as x25StatOutInterrupts  
  Counter as x25StatOutDataPackets  
  Gauge as x25StatOutgoingCircuits  
  Gauge as x25StatIncomingCircuits  
  Gauge as x25StatTwowayCircuits  
  Counter as x25StatRestartTimeouts  
  Counter as x25StatCallTimeouts  
  Counter as x25StatResetTimeouts  
  Counter as x25StatClearTimeouts  
  Counter as x25StatDataRxmtTimeouts  
  Counter as x25StatInterruptTimeouts  
  Counter as x25StatRetryCountExceededs  
  Counter as x25StatClearCountExceededs  

X25ChannelEntry  
SEQUENCE    
  IfIndexType as x25ChannelIndex  
  INTEGER as x25ChannelLIC  
  INTEGER as x25ChannelHIC  
  INTEGER as x25ChannelLTC  
  INTEGER as x25ChannelHTC  
  INTEGER as x25ChannelLOC  
  INTEGER as x25ChannelHOC  

X25CircuitEntry  
SEQUENCE    
  IfIndexType as x25CircuitIndex  
  INTEGER as x25CircuitChannel  
  INTEGER as x25CircuitStatus  
  TimeTicks as x25CircuitEstablishTime  
  INTEGER as x25CircuitDirection  
  Counter as x25CircuitInOctets  
  Counter as x25CircuitInPdus  
  Counter as x25CircuitInRemotelyInitiatedResets  
  Counter as x25CircuitInProviderInitiatedResets  
  Counter as x25CircuitInInterrupts  
  Counter as x25CircuitOutOctets  
  Counter as x25CircuitOutPdus  
  Counter as x25CircuitOutInterrupts  
  Counter as x25CircuitDataRetransmissionTimeouts  
  Counter as x25CircuitResetTimeouts  
  Counter as x25CircuitInterruptTimeouts  
  OBJECT IDENTIFIER as x25CircuitCallParamId  
  X121Address as x25CircuitCalledDteAddress  
  X121Address as x25CircuitCallingDteAddress  
  X121Address as x25CircuitOriginallyCalledAddress  
  DisplayString as x25CircuitDescr  

X25ClearedCircuitEntry  
SEQUENCE    
  PositiveInteger as x25ClearedCircuitIndex  
  IfIndexType as x25ClearedCircuitPleIndex  
  TimeTicks as x25ClearedCircuitTimeEstablished  
  TimeTicks as x25ClearedCircuitTimeCleared  
  INTEGER as x25ClearedCircuitChannel  
  INTEGER as x25ClearedCircuitClearingCause  
  INTEGER as x25ClearedCircuitDiagnosticCode  
  Counter as x25ClearedCircuitInPdus  
  Counter as x25ClearedCircuitOutPdus  
  X121Address as x25ClearedCircuitCalledAddress  
  X121Address as x25ClearedCircuitCallingAddress  
  OCTET STRING as x25ClearedCircuitClearFacilities  

X25CallParmEntry  
SEQUENCE    
  PositiveInteger as x25CallParmIndex  
  EntryStatus as x25CallParmStatus  
  PositiveInteger as x25CallParmRefCount  
  INTEGER as x25CallParmInPacketSize  
  INTEGER as x25CallParmOutPacketSize  
  INTEGER as x25CallParmInWindowSize  
  INTEGER as x25CallParmOutWindowSize  
  INTEGER as x25CallParmAcceptReverseCharging  
  INTEGER as x25CallParmProposeReverseCharging  
  INTEGER as x25CallParmFastSelect  
  INTEGER as x25CallParmInThruPutClasSize  
  INTEGER as x25CallParmOutThruPutClasSize  
  DisplayString as x25CallParmCug  
  DisplayString as x25CallParmCugoa  
  DisplayString as x25CallParmBcug  
  OCTET STRING as x25CallParmNui  
  INTEGER as x25CallParmChargingInfo  
  DisplayString as x25CallParmRpoa  
  INTEGER as x25CallParmTrnstDly  
  DisplayString as x25CallParmCallingExt  
  DisplayString as x25CallParmCalledExt  
  INTEGER as x25CallParmInMinThuPutCls  
  INTEGER as x25CallParmOutMinThuPutCls  
  OCTET STRING as x25CallParmEndTrnsDly  
  OCTET STRING as x25CallParmPriority  
  DisplayString as x25CallParmProtection  
  INTEGER as x25CallParmExptData  
  OCTET STRING as x25CallParmUserData  
  OCTET STRING as x25CallParmCallingNetworkFacilities  
  OCTET STRING as x25CallParmCalledNetworkFacilities