RFC1407-EXT-MIB

File: RFC1407-EXT-MIB.mib (12329 bytes)

Imported modules

RFC-1212 RFC1155-SMI CENTILLION-ROOT-MIB
RFC1407-MIB

Imported symbols

OBJECT-TYPE Gauge extensions
dsx3TotalIndex EnableIndicator

Defined Objects

cnds3e3Ext 1.3.6.1.4.1.930.3.6
OBJECT IDENTIFIER    

cndsx3Oper 1.3.6.1.4.1.930.3.6.1
OBJECT IDENTIFIER    

cndsx3OperTable 1.3.6.1.4.1.930.3.6.1.1
This table contains the configuration information that are operational currently. This table contains all the objects defined in dsx3ConfigTable plus some additional. This table is read only
OBJECT-TYPE    
  SEQUENCE OF  
    Cndsx3OperEntry

cndsx3OperEntry 1.3.6.1.4.1.930.3.6.1.1.1
An entry in the DS3/E3 Operational Configuration table.
OBJECT-TYPE    
  Cndsx3OperEntry  

cndsx3OperLineIndex 1.3.6.1.4.1.930.3.6.1.1.1.1
This object is the identifier of a DS3/E3 Interface on a managed device.
OBJECT-TYPE    
  INTEGER 1..65535  

cndsx3OperLineType 1.3.6.1.4.1.930.3.6.1.1.1.2
This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The dsx3ClearChannel value means that the C-bits are not used except for sending/receiving AIS. The values, in sequence, describe: TITLE: SPECIFICATION: dsx3M23 ANSI T1.107-1988 dsx3SYNTRAN ANSI T1.107-1988 dsx3CbitParity ANSI T1.107a-1989 dsx3ClearChannel ANSI T1.102-1987 e3Framed CCITT G.751 e3Plcp ETSI T/NA(91)18.
OBJECT-TYPE    
  INTEGER dsx3other(1), dsx3M23(2), dsx3SYNTRAN(3), dsx3CbitParity(4), dsx3ClearChannel(5), e3other(6), e3Framed(7), e3Plcp(8)  

cndsx3OperLoopbackConfig 1.3.6.1.4.1.930.3.6.1.1.1.3
This variable represents the loopback configuration of the DS3/E3 interface. dsx3NoLoop Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as it's value. dsx3PayloadLoop The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. dsx3LineLoop The received signal at this interface does not go through the device (minimum penetration) but is looped back out. dsx3OtherLoop Loopbacks that are not defined here.
OBJECT-TYPE    
  INTEGER dsx3NoLoop(1), dsx3PayloadLoop(2), dsx3LineLoop(3), dsx3OtherLoop(4)  

cndsx3OperLineStatus 1.3.6.1.4.1.930.3.6.1.1.1.4
This variable indicates the Line Status of the interface. It contains loopback state information and failure state information. The dsx3LineStatus is a bit map represented as a sum, therefore, it can represent multiple failures and a loopback (see dsx3LoopbackConfig object for the type of loopback) simultaneously. The dsx3NoAlarm should be set if and only if no other flag is set. The various bit positions are: 1 dsx3NoAlarm No alarm present 2 dsx3RcvRAIFailure Receiving Yellow/Remote Alarm Indication 4 dsx3XmitRAIAlarm Transmitting Yellow/Remote Alarm Indication 8 dsx3RcvAIS Receiving AIS failure state 16 dsx3XmitAIS Transmitting AIS 32 dsx3LOF Receiving LOF failure state 64 dsx3LOS Receiving LOS failure state 128 dsx3LoopbackState Looping the received signal 256 dsx3RcvTestCode Receiving a Test Pattern 512 dsx3OtherFailure any line status not defined here
OBJECT-TYPE    
  INTEGER 1..1023  

cndsx3OperTransmitClockSource 1.3.6.1.4.1.930.3.6.1.1.1.5
The source of Transmit Clock. is derived from the recovered receive clock of another DS3 interface.
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), throughTiming(3)  

cndsx3OperPlcpLOFEvent 1.3.6.1.4.1.930.3.6.1.1.1.6
Indicates PLCP Loss of Frame event. The following value is read-only: on(1).......Loss of Frame event is present off(2)......Loss of Frame event is not present
OBJECT-TYPE    
  INTEGER on(1), off(2)  

cndsx3OperG832CellDelineation 1.3.6.1.4.1.930.3.6.1.1.1.7
Indicates Cell Delineation events. The following value is read-only: on(1).......Cell Delineation event is present off(2)......Cell Delineation event is not present
OBJECT-TYPE    
  INTEGER on(1), off(2)  

cndsx3OperLineBuildOut 1.3.6.1.4.1.930.3.6.1.1.1.8
Indicates line buildout status
OBJECT-TYPE    
  EnableIndicator  

cndsx3OperScramblingEnable 1.3.6.1.4.1.930.3.6.1.1.1.9
This field indicates if scrambing is enabled or disabled.
OBJECT-TYPE    
  EnableIndicator  

cndsx3OperE3ConfigType 1.3.6.1.4.1.930.3.6.1.1.1.10
This object shows E3Config mode. The following value is read-only: other(1).......other than g751 and g832 g751(2)........E3ConfigType is G751 g832(3)........E3ConfigType is G832
OBJECT-TYPE    
  INTEGER other(1), g751(2), g832(3)  

cndsx3TotalExt 1.3.6.1.4.1.930.3.6.2
OBJECT IDENTIFIER    

cndsx3TotalExtTable 1.3.6.1.4.1.930.3.6.2.1
This table contains the counters that are additional to the existing dsx3TotalTable
OBJECT-TYPE    
  SEQUENCE OF  
    Cndsx3TotalExtEntry

cndsx3TotalExtEntry 1.3.6.1.4.1.930.3.6.2.1.1
An entry in the DS3/E3 TotalExt table.
OBJECT-TYPE    
  Cndsx3TotalExtEntry  

cndsx3CellPayloadHECError 1.3.6.1.4.1.930.3.6.2.1.1.1
A counter of Payload HEC errors.
OBJECT-TYPE    
  Gauge  

cndsx3ConfigExt 1.3.6.1.4.1.930.3.6.3
OBJECT IDENTIFIER    

cndsx3ConfigExtTable 1.3.6.1.4.1.930.3.6.3.1
This table contains the configurable parameters that are additional to the existing dsx3ConfigTable
OBJECT-TYPE    
  SEQUENCE OF  
    Cndsx3ConfigExtEntry

cndsx3ConfigExtEntry 1.3.6.1.4.1.930.3.6.3.1.1
An entry in the DS3/E3 ConfigExt table.
OBJECT-TYPE    
  Cndsx3ConfigExtEntry  

cndsx3LineBuildOut 1.3.6.1.4.1.930.3.6.3.1.1.1
Indicates LineBuild Out status
OBJECT-TYPE    
  EnableIndicator  

cndsx3LineIndex 1.3.6.1.4.1.930.3.6.3.1.1.2
This object is the identifier of a DS3/E3 Interface on a managed device.
OBJECT-TYPE    
  INTEGER 1..65535  

cndsx3ScramblingEnable 1.3.6.1.4.1.930.3.6.3.1.1.3
This field indicates if scrambing is enabled or disabled.
OBJECT-TYPE    
  EnableIndicator  

cndsx3E3ConfigType 1.3.6.1.4.1.930.3.6.3.1.1.4
This object allows to switch between E3 G751 and G832 mode. The following value is read-only: other(1).......other than g751 and g832 The following value is read-write: g751(2)........E3ConfigType is G751 g832(3)........E3ConfigType is G832
OBJECT-TYPE    
  INTEGER other(1), g751(2), g832(3)  

Defined Objects

Cndsx3TotalExtEntry  
SEQUENCE    
  Gauge as cndsx3CellPayloadHECError  

Cndsx3ConfigExtEntry  
SEQUENCE    
  EnableIndicator as cndsx3LineBuildOut  
  INTEGER as cndsx3LineIndex  
  EnableIndicator as cndsx3ScramblingEnable  
  INTEGER as cndsx3E3ConfigType  

Cndsx3OperEntry  
SEQUENCE    
  INTEGER as cndsx3OperLineIndex  
  INTEGER as cndsx3OperLineType  
  INTEGER as cndsx3OperLoopbackConfig  
  INTEGER as cndsx3OperLineStatus  
  INTEGER as cndsx3OperTransmitClockSource  
  INTEGER as cndsx3OperPlcpLOFEvent  
  INTEGER as cndsx3OperG832CellDelineation  
  EnableIndicator as cndsx3OperLineBuildOut  
  EnableIndicator as cndsx3OperScramblingEnable  
  INTEGER as cndsx3OperE3ConfigType