EXTREME-TRAP-MIB

File: EXTREME-TRAP-MIB.mib (7892 bytes)

Imported modules

EXTREME-BASE-MIB EXTREME-SYSTEM-MIB EXTREME-ESRP-MIB
EXTREME-VLAN-MIB EXTREME-EDP-MIB RFC1213-MIB
IF-MIB SNMPv2-SMI

Imported symbols

extremenetworks extremeV1Traps extremeSlotNumber
extremeSlotModuleConfiguredType extremeSlotModuleInsertedType extremeSlotModuleState
extremePowerSupplyNumber extremeFanNumber extremeCurrentTemperature
extremeEsrpGroup extremeEsrpState extremeEsrpNetAddress
extremeEsrpActivePorts extremeEsrpInternalActivePorts extremeEsrpTrackedActivePorts
extremeEsrpTrackedIpRoutes extremeVlanIfIndex extremeVlanIfDescr
extremeEdpPortIfIndex extremeEdpNeighborId extremeEdpEntryAge
extremeEdpNeighborVlanName extremeEdpNeighborVlanIpAddress sysUpTime
sysDescr ifPhysAddress ifDescr
ifAlias NOTIFICATION-TYPE

Defined Objects

extremeOverheat 1.3.6.1.4.1.1916.0.6
A overheat trap indicates that the on board tempature sensor has reported a overheat condition. System will shutdown until unit has suficiently cooled such that operation may begin again. A cold start trap will be issued when the unit has come back on line.
NOTIFICATION-TYPE    
  sysUpTime  
  sysDescr  
  extremeCurrentTemperature  

extremeFanfailed 1.3.6.1.4.1.1916.0.7
A fan failed trap indicates one or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation.
NOTIFICATION-TYPE    
  sysUpTime  
  sysDescr  
  extremeFanNumber  

extremeFanOK 1.3.6.1.4.1.1916.0.8
A fan has transitioned out of a failure state and is now operating correctly.
NOTIFICATION-TYPE    
  sysUpTime  
  sysDescr  
  extremeFanNumber  

extremeInvalidLoginAttempt 1.3.6.1.4.1.1916.0.9
A user attempted to login to console or by telnet but was refused access due to incorrect username or password
NOTIFICATION-TYPE    
  sysUpTime  
  sysDescr  

extremePowerSupplyFail 1.3.6.1.4.1.1916.0.10
One or more sources of power to this agent has failed. Presumably a redundant power-supply has taken over.
NOTIFICATION-TYPE    
  sysUpTime  
  sysDescr  
  extremePowerSupplyNumber  

extremePowerSupplyGood 1.3.6.1.4.1.1916.0.11
One or more previously bad sources of power to this agent has come back to life without causing an agent restart.
NOTIFICATION-TYPE    
  sysUpTime  
  sysDescr  
  extremePowerSupplyNumber  

extremeRpsAlarm 1.3.6.1.4.1.1916.0.12
Attached Redundant Power Supply device is indicating an alarm condition.
NOTIFICATION-TYPE    
  sysUpTime  
  sysDescr  

extremeRpsNoAlarm 1.3.6.1.4.1.1916.0.13
Attached Redundant Power Supply device is no longer indicating an alarm condition.
NOTIFICATION-TYPE    
  sysUpTime  
  sysDescr  

extremeSmartTrap 1.3.6.1.4.1.1916.0.14
Signifies that the value of one of the object identifiers (or the value of an object below that in the MIB tree) defined in the extremeSmartTrapRulesTable has changed, and hence a new entry has been created in the extremeSmartTrapInstanceTable. Such a trap is sent at most once every thirty seconds if one or more entry was created in the last thirty seconds.
NOTIFICATION-TYPE    
  sysUpTime  
  sysDescr  

extremeModuleStateChanged 1.3.6.1.4.1.1916.0.15
Signifies that the value of the extremeSlotModuleState for the specified extremeSlotNumber has changed.
NOTIFICATION-TYPE    
  sysUpTime  
  extremeSlotNumber  
  extremeSlotModuleConfiguredType  
  extremeSlotModuleInsertedType  
  extremeSlotModuleState  

extremeEsrpStateChange 1.3.6.1.4.1.1916.0.17
Signifies Esrp state change
NOTIFICATION-TYPE    
  sysUpTime  
  sysDescr  
  extremeVlanIfIndex  
  extremeVlanIfDescr  
  extremeEsrpGroup  
  extremeEsrpState  
  extremeEsrpNetAddress  
  ifPhysAddress  
  extremeEsrpActivePorts  
  extremeEsrpInternalActivePorts  
  extremeEsrpTrackedActivePorts  
  extremeEsrpTrackedIpRoutes  

extremeSlbUnitAdded 1.3.6.1.4.1.1916.0.18
The server load balancer has activated a group of virtual servers that it normally would not activate. This may be due to the failure of another server load balancer.
NOTIFICATION-TYPE    

extremeSlbUnitRemoved 1.3.6.1.4.1.1916.0.19
The server load balancer has deactivated a group of virtual servers that it normally has active. This indicates that something is wrong in the server load balancer; for example, its ping check may be failing.
NOTIFICATION-TYPE    

extremeEdpNeighborAdded 1.3.6.1.4.1.1916.0.20
This node discovers a new neighbor through Extreme Discovery Protocol.
NOTIFICATION-TYPE    
  sysUpTime  
  extremeEdpPortIfIndex  
  extremeEdpNeighborId  
  extremeEdpEntryAge  
  ifAlias  
  ifDescr  

extremeEdpNeighborRemoved 1.3.6.1.4.1.1916.0.21
No EDP updates are received from this neighbor within the configured timeout period and this neighbor entry is aged out by the device.
NOTIFICATION-TYPE    
  sysUpTime  
  extremeEdpPortIfIndex  
  extremeEdpNeighborId  
  extremeEdpEntryAge  
  ifAlias  
  ifDescr