OPTIMUX-MIB

File: OPTIMUX-MIB.mib (178372 bytes)

Imported modules

RFC1213-MIB RFC1155-SMI RFC-1212
RFC-1215 IF-MIB DS1-MIB
DS3-MIB RAD-MIB SNMPv2-SMI
SNMPv2-TC SNMP-FRAMEWORK-MIB SWL2MGMT-MIB
MULTI-MEDIA-MIB-TC

Imported symbols

DisplayString enterprises IpAddress
OBJECT-TYPE TRAP-TYPE ifIndex
InterfaceIndex ifAlias dsx1LoopbackStatus
dsx1LineStatus dsx1LineStatusLastChange dsx3LoopbackStatus
dsx3LineStatus radSysWanEvents agnLed
agnIndication atmInterfaceAlarmStatus alarmSeverity
alarmState NOTIFICATION-TYPE OBJECT-IDENTITY
Integer32 Counter32 RowStatus
MacAddress TAddress SnmpAdminString
VlanIndex MmAliasTag MmAliasAddress
MmTAddressTag MmEndpointID MmH323EndpointType
MmGatekeeperID

Defined Objects

rad 1.3.6.1.4.1.164
OBJECT IDENTIFIER    

radWan 1.3.6.1.4.1.164.3
OBJECT IDENTIFIER    

wanGen 1.3.6.1.4.1.164.3.1
OBJECT IDENTIFIER    

diverseIfWanGen 1.3.6.1.4.1.164.3.1.6
OBJECT IDENTIFIER    

v51If 1.3.6.1.4.1.164.3.1.6.6
OBJECT IDENTIFIER    

v51IfEvents 1.3.6.1.4.1.164.3.1.6.6.0
The events for the WAN V5.1.
OBJECT-IDENTITY    

activeVariantTrap 1.3.6.1.4.1.164.3.1.6.6.0.1
This trap is sent when the Active Variant of a Link is changed (that includes the case when a user performs Save to the Variant that is Active).
NOTIFICATION-TYPE    
  v51MlCurrActiveVar  

v51General 1.3.6.1.4.1.164.3.1.6.6.1
OBJECT IDENTIFIER    

npl 1.3.6.1.4.1.164.3.1.6.6.1.1
OBJECT IDENTIFIER    

nplMode 1.3.6.1.4.1.164.3.1.6.6.1.1.1
NPL Mode.
OBJECT-TYPE    
  INTEGER auto(2), manual(3)  

nplCountry 1.3.6.1.4.1.164.3.1.6.6.1.1.2
National Protocol Country.
OBJECT-TYPE    
  INTEGER none(1), france(2), germany(3)  

nplVoicePathDuration 1.3.6.1.4.1.164.3.1.6.6.1.1.3
Maximum time of a voice path, in msec.
OBJECT-TYPE    
  Integer32  

nplPulseTable 1.3.6.1.4.1.164.3.1.6.6.1.1.4
NPL Pulse table. This table is written directly to the agent.
OBJECT-TYPE    
  SEQUENCE OF  
    NplPulseEntry

nplPulseEntry 1.3.6.1.4.1.164.3.1.6.6.1.1.4.1
An entry in table nplPulseTable.
OBJECT-TYPE    
  NplPulseEntry  

nplPulseType 1.3.6.1.4.1.164.3.1.6.6.1.1.4.1.1
Pulse Type
OBJECT-TYPE    
  INTEGER meteringPulse1(1), meteringPulse2(2), initRinging1(3), initRinging2(4), normalBattery(237), noBattery(250), reducedBattery(251), reversePolarity(254), normalPolarity(255)  

nplPulseValid 1.3.6.1.4.1.164.3.1.6.6.1.1.4.1.2
Validity of the Pulse Type.
OBJECT-TYPE    
  INTEGER notValid(2), valid(3)  

nplPulseDurationType 1.3.6.1.4.1.164.3.1.6.6.1.1.4.1.3
Pulse Duration Type. - If meteringPulse1 and meteringPulse2 are both 'valid', the value of this object must be different for them. - If initRinging1 and initRinging2 are both 'valid', the value of this object must be different for them.
OBJECT-TYPE    
  Integer32 0..31  

nplPulseOnTime 1.3.6.1.4.1.164.3.1.6.6.1.1.4.1.4
How much time the pulse is ON, in msec. 0 is a valid value only when nplPulseValid=notValid.
OBJECT-TYPE    
  Integer32 0..990  

nplPulseOffTime 1.3.6.1.4.1.164.3.1.6.6.1.1.4.1.5
How much time the pulse is OFF, in msec.
OBJECT-TYPE    
  Integer32 0..990  

v51Variant 1.3.6.1.4.1.164.3.1.6.6.2
OBJECT IDENTIFIER    

v51VarTable 1.3.6.1.4.1.164.3.1.6.6.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    V51VarEntry

v51VarEntry 1.3.6.1.4.1.164.3.1.6.6.2.1.1
An entry in table v51VarTable.
OBJECT-TYPE    
  V51VarEntry  

v51VarCnfgIdx 1.3.6.1.4.1.164.3.1.6.6.2.1.1.1
This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. Write is allowed only to TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

v51VarSltIdx 1.3.6.1.4.1.164.3.1.6.6.2.1.1.2
Slot Index. For V5.2, this index will be the Slot of the V5.2 Master ML.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

v51VarPrtIdx 1.3.6.1.4.1.164.3.1.6.6.2.1.1.3
This attribute indicates a unique port number of the ML having V5 interface. Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104), notApplicable(255) - for V5.2 only.
OBJECT-TYPE    
  Integer32  

v51VarIdx 1.3.6.1.4.1.164.3.1.6.6.2.1.1.4
Variant Id. Valid values: - for Current Cnfg: 0..127 - for Tmp Cnfg: until MP R9 : 255 only. from MP R10: 0..127.
OBJECT-TYPE    
  Integer32 0..255  

v51VarPstnCch 1.3.6.1.4.1.164.3.1.6.6.2.1.1.5
This object indicates which TS will be used for PSTN C channel. For V5.2 - notApplicable.
OBJECT-TYPE    
  INTEGER notApplicable(1), ts15(2), ts16(3), ts31(4)  

v51VarIsdnSTypeCch 1.3.6.1.4.1.164.3.1.6.6.2.1.1.6
This object indicates which TS will be used for S-Type C channel. For V5.2 - notApplicable.
OBJECT-TYPE    
  INTEGER notApplicable(1), ts15(2), ts16(3), ts31(4)  

v51VarDescription 1.3.6.1.4.1.164.3.1.6.6.2.1.1.7
This object describes the Variant.
OBJECT-TYPE    
  DisplayString  

v51VarStatus 1.3.6.1.4.1.164.3.1.6.6.2.1.1.8
This object reports the status of an existing Variant of a link. notActive - the variant exists on this link but is not active active - the variant exists on this link AND is active activeReq - the variant exists on this link and it was requested to be active, but the request is still in negotiation (it can be either accepted as active, or not). This object is not applicable for v51VarCnfgIdx=255=TmpCnfg.
OBJECT-TYPE    
  INTEGER notApplicable(1), notActive(2), active(3), activeReq(4)  

v51VarRowStatus 1.3.6.1.4.1.164.3.1.6.6.2.1.1.9
This object enables to create new entries and delete existing entries from the table. It is applicable only from MP R10.
OBJECT-TYPE    
  INTEGER notApplicable(1), notValid(2), valid(3)  

v51VarCfgTable 1.3.6.1.4.1.164.3.1.6.6.2.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    V51VarCfgEntry

v51VarCfgEntry 1.3.6.1.4.1.164.3.1.6.6.2.2.1
An entry in table v51VarCfgTable.
OBJECT-TYPE    
  V51VarCfgEntry  

v51VarCfgIndex 1.3.6.1.4.1.164.3.1.6.6.2.2.1.1
This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg.
OBJECT-TYPE    
  Integer32 1..255  

v51VarCfgSltIdx 1.3.6.1.4.1.164.3.1.6.6.2.2.1.2
Slot Index. For V5.2, this index will be the Slot of the V5.2 Master ML.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

v51VarCfgPrtIdx 1.3.6.1.4.1.164.3.1.6.6.2.2.1.3
This attribute indicates a unique port number of the ML having V5 interface. Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104) notApplicable(255) - for V5.2 only.
OBJECT-TYPE    
  Integer32  

v51VarCfgIdx 1.3.6.1.4.1.164.3.1.6.6.2.2.1.4
Variant Id. Valid values: - for Current Cnfg: 0..127 - for Tmp Cnfg: until MP R9 : 255 only. from MP R10: 0..127.
OBJECT-TYPE    
  Integer32 0..255  

v51VarCfgTsIdx 1.3.6.1.4.1.164.3.1.6.6.2.2.1.5
For V5.1: Time Slot index (1..31). For V5.2: Running Index (1..1320) for Address Table.
OBJECT-TYPE    
  Integer32  

v51VarCfgTsType 1.3.6.1.4.1.164.3.1.6.6.2.2.1.6
Time Slot Type.
OBJECT-TYPE    
  INTEGER nc(1), pstn(2), isdnB1(3), isdnB2(4), cChannel(5), permanentB1(6), permanentB2(7), semiPermanentB1(8), semiPermanentB2(9)  

v51VarCfgPrtId 1.3.6.1.4.1.164.3.1.6.6.2.2.1.7
This object indicates the IO Port Id this TS is connected to. For V5.2, the Port Id is a concatenation of SS:PP:TS of the port connected to V5.2 Master. SS=IO Slot (1..12) PP=Port (01..04) TS = TS (00 for ports that don't have TSs ..31). Example: 50327 means IO-5, port-3, TS27.
OBJECT-TYPE    
  Integer32 0..16777215  

v51VarCfgEfL3Addr 1.3.6.1.4.1.164.3.1.6.6.2.2.1.8
This object indicates the Address of the IO port this TS is connected to. The IO port is identified according to its Address: - for ISDN ports: EF Address. Valid values: 0..8175 - for PSTN ports: L3 Address. Valid values: 0..32767 65535=notApplicable (FFFF).
OBJECT-TYPE    
  Integer32 0..65535  

v51VarCfgFTypeCch 1.3.6.1.4.1.164.3.1.6.6.2.2.1.9
For V5.1 - this object indicates which TS will be used for F-Type C channel. notApplicable (1), ts15 (2), ts16 (3), ts31 (4) For V5.2 - this object indicates the Logical C Channel F Type (0..65535). 65536=not applicable in this case.
OBJECT-TYPE    
  Integer32  

v51VarCfgPTypeCch 1.3.6.1.4.1.164.3.1.6.6.2.2.1.10
For V5.1 - This object indicates which TS will be used for P-Type C channel. notApplicable (1), ts15 (2), ts16 (3), ts31 (4) For V5.2 - this object indicates the Logical C Channel P Type (0..65535). 65536=not applicable in this case.
OBJECT-TYPE    
  Integer32  

v51VarCfgConSlt 1.3.6.1.4.1.164.3.1.6.6.2.2.1.11
The Slot containing the IO port this TS is connected to. For V5.2 this object is notApplicable.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

v51VarCfgConPrt 1.3.6.1.4.1.164.3.1.6.6.2.2.1.12
The IO Port this TS is connected to. Valid values: exPrt1 (1)..exPrt12 (12), inPrt1(101)..inPrt4(104). 100=noConnect For V5.2 this object is notApplicable=255.
OBJECT-TYPE    
  Integer32  

v51VarCfgIoState 1.3.6.1.4.1.164.3.1.6.6.2.2.1.13
The State of the IO port this TS is connected to. This object is not applicable for v51VarCfgIndex=255=TmpCnfg. normal(2) - will be used for operating normally (operate) localBlocked(5) - will be used for general Block state
OBJECT-TYPE    
  INTEGER notUsed(1), normal(2), blockReqDenied(3), remoteBlocked(4), localBlocked(5), unblockReqDenied(6), duringBlock(7), duringUnblock(8), localLoop(9), remoteLoop(10), localUnblock(11), remoteUnblock(12)  

v51VarCfgBlock 1.3.6.1.4.1.164.3.1.6.6.2.2.1.14
This object indicates if this TS will be Blocked or not and how: block - done locally blockRequest - according to external request of the telephone exchange.
OBJECT-TYPE    
  INTEGER notApplicable(1), unBlock(2), block(3), blockRequest(4)  

v51VarCfgExtDch 1.3.6.1.4.1.164.3.1.6.6.2.2.1.15
For V5.1: This object indicates if this TS is an ISDN D channel that comes via Bypass from a non-V5.1 ML. For V5.2: this object will be notApplicable (not supported).
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

v51VarCfgExtDchSlot 1.3.6.1.4.1.164.3.1.6.6.2.2.1.16
This object is applicable only if v51VarCfgExtDch=yes(3). It indicates the Slot of the non-V5.1 ML on which the External D channel TS is defined (and is transferred via Bypass between the V5.1 ML and the non-V5.1 ML.) Not Applicable for V5.2 (it is part of Port Id).
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

v51VarCfgExtDchPort 1.3.6.1.4.1.164.3.1.6.6.2.2.1.17
This object is applicable only if v51VarCfgExtDch=yes(3). It indicates the Port on the Slot of 'v51VarCfgExtDchSlot' of the non-V5.1 ML on which the External D channel TS is defined (and is transferred via Bypass between the V5.1 ML and the non-V5.1 ML.) Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104). 100=noConnect. Not Applicable for V5.2 (255; it is part of Port Id).
OBJECT-TYPE    
  Integer32  

v51VarCfgExtDchTs 1.3.6.1.4.1.164.3.1.6.6.2.2.1.18
This object is applicable only if v51VarCfgExtDch=yes(3). It indicates the TS on the non-V5 ML on which the External D channel TS is defined (and is transferred via Bypass between the V5 ML and the non-V5 ML.) For V5.1: 0=notApplicable For V5.2: 0=None, 32=notApplicable.
OBJECT-TYPE    
  Integer32 0..32  

v51VarCfgExtDchCmpr 1.3.6.1.4.1.164.3.1.6.6.2.2.1.19
For V5.1 - this object is applicable only if v51VarCfgExtDch=yes(3). It indicates if this ISDN D channel TS is Compressed or not.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

v51VarCfgExtDchRate 1.3.6.1.4.1.164.3.1.6.6.2.2.1.20
For V5.1 - this object is applicable only if v51VarCfgExtDch=yes(3). It indicates the Rate of the ISDN D channel.
OBJECT-TYPE    
  INTEGER notApplicable(1), twoBits(2), fourBits(3), eightBits(4)  

v51VarCfgExtDchStartBit 1.3.6.1.4.1.164.3.1.6.6.2.2.1.21
For V5.1 - this object is applicable only if v51VarCfgExtDch=yes(3). It indicates the Start Bit of the ISDN D channel on the TS of the non-V5.1 ML on which it is defined. Valid values: - for v51VarCfgExtDchRate=twoBits(2): 1, 3, 5, 7 - for v51VarCfgExtDchRate=fourBits(3): 1, 5 - for v51VarCfgExtDchRate=eightBits(4): 1 - 0=notApplicable
OBJECT-TYPE    
  Integer32 0..7  

v51VarCfgSTypeCch 1.3.6.1.4.1.164.3.1.6.6.2.2.1.22
This object is supported only by V5.2. It indicates the Logical C Channel S Type (0..65535). 65536=not applicable.
OBJECT-TYPE    
  Integer32  

v51VarCfgStatus 1.3.6.1.4.1.164.3.1.6.6.2.2.1.23
This object is supported only by V5.2. It enables to create new entries and delete existing entries from the table.
OBJECT-TYPE    
  INTEGER notApplicable(1), notValid(2), valid(3)  

v51VarCfgV52MasterTsa 1.3.6.1.4.1.164.3.1.6.6.2.2.1.24
This object is supported only by V5.2. This will be the V5.2 Master, Switch Allocated Location. It is a concatenation of SS:PP:TS of the V5.2 Master. It indicates which is the exact port and TS allocated by the Local Exchange on the V5.2 Link. SS=IO Slot (1..12) PP=Port (01..04) TS = TS (1..31). Example: 50323 means IO-5, port-3, TS23.
OBJECT-TYPE    
  Integer32  

v5VarCchTable 1.3.6.1.4.1.164.3.1.6.6.2.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    V5VarCchEntry

v5VarCchEntry 1.3.6.1.4.1.164.3.1.6.6.2.3.1
An entry in table v5VarCchTable.
OBJECT-TYPE    
  V5VarCchEntry  

v5VarCchCfgIndex 1.3.6.1.4.1.164.3.1.6.6.2.3.1.1
This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg.
OBJECT-TYPE    
  Integer32 1..255  

v5VarCchVarIdx 1.3.6.1.4.1.164.3.1.6.6.2.3.1.2
Variant Id. Valid values: 0..127.
OBJECT-TYPE    
  Integer32 0..127  

v5VarCchIdx 1.3.6.1.4.1.164.3.1.6.6.2.3.1.3
C-CH Id. There are only 8 possible C-CHs per Variant.
OBJECT-TYPE    
  Integer32 1..8  

v5VarCchType 1.3.6.1.4.1.164.3.1.6.6.2.3.1.4
C-CH Type.
OBJECT-TYPE    
  INTEGER none(2), primary(3), secondary(4), regular(5), standby(6)  

v5VarCchPhyLinkNo 1.3.6.1.4.1.164.3.1.6.6.2.3.1.5
The Physical Link Number of the card (1..4). This object is applicable only if v51VarCchType is not 'none'. notApplicable=255.
OBJECT-TYPE    
  Integer32  

v5VarCchLogicalId 1.3.6.1.4.1.164.3.1.6.6.2.3.1.6
The Logical C-CH Id. (0..65535) When v51VarCchType is 'none', this object is irrelevant.
OBJECT-TYPE    
  Integer32 0..65535  

v5VarCchTs 1.3.6.1.4.1.164.3.1.6.6.2.3.1.7
The C-CH TS. Valid values: 16, 15, 31. If v51VarCchType=primary or secondary, the value must be 16 (RO). This object is applicable only if v51VarCchType is not 'none'. notApplicable=0.
OBJECT-TYPE    
  Integer32  

v5VarCchPstn 1.3.6.1.4.1.164.3.1.6.6.2.3.1.8
PSTN C-CH. Only one entry can have the value 'yes'. notApplicable - when v51VarCchType is none, secondary or standby.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

v5VarCchIsdnTypes 1.3.6.1.4.1.164.3.1.6.6.2.3.1.9
ISDN Types of C-CH. This object is a sum of 2**n, where n=Bit No. and Bit is '1': Bit No. ISDN Type 0 P 1 F 2 S Bit value '1'= Yes Bit value '0'= No Example: P=No, F=Yes, S=Yes (110H) will have the value 6. Each Type is NA (notApplicable) when v51VarCchType is none, secondary or standby. There is no special value for it, since each type can have only 2 values (1 or 0). When this object is NA, Agent will not refer its value (don't care).
OBJECT-TYPE    
  Integer32  

v5VarStatTable 1.3.6.1.4.1.164.3.1.6.6.2.4
This is a RO table. It includes only the Active Addresses of the Active Variant, their minimal Config data and Status.
OBJECT-TYPE    
  SEQUENCE OF  
    V5VarStatEntry

v5VarStatEntry 1.3.6.1.4.1.164.3.1.6.6.2.4.1
An entry in table v5VarStatTable.
OBJECT-TYPE    
  V5VarStatEntry  

v5VarStatIdx 1.3.6.1.4.1.164.3.1.6.6.2.4.1.1
Running Index (1..120). Up to 120 calls can be active at the same time on the Active Variant.
OBJECT-TYPE    
  Integer32  

v5VarStatPrtId 1.3.6.1.4.1.164.3.1.6.6.2.4.1.2
This object indicates the IO Port Id, the Address is connected to. The Port Id is a concatenation of SS:PP:TS of the port connected to an Address of the Active Variant running on the V5.2 Master card. SS=IO Slot (1..12) PP=Port (01..04) TS = TS (00 for ports that don't have TSs ..31). Example: 50327 means IO-5, port-3, TS27.
OBJECT-TYPE    
  Integer32  

v5VarStatPortType 1.3.6.1.4.1.164.3.1.6.6.2.4.1.3
Address Port Type.
OBJECT-TYPE    
  INTEGER nc(1), pstn(2), isdnB1(3), isdnB2(4), cChannel(5), permanentB1(6), permanentB2(7), semiPermanentB1(8), semiPermanentB2(9)  

v5VarStatEfL3Addr 1.3.6.1.4.1.164.3.1.6.6.2.4.1.4
This object indicates the EF/L3 Address of the IO port this entry is connected to. The IO port is identified according to its EF/L3 Address: - for ISDN ports: EF Address. Valid values: 0..8175 - for PSTN ports: L3 Address. Valid values: 0..32767 65535=notApplicable (FFFF).
OBJECT-TYPE    
  Integer32 0..65535  

v5VarStatPortState 1.3.6.1.4.1.164.3.1.6.6.2.4.1.5
The State of the IO port this Address entry is connected to. The values were designed to match the relevant values of v51VarCfgIoState.
OBJECT-TYPE    
  INTEGER notUsed(1), normalOperation(2), block(5), localUnblock(11), remoteUnblock(12)  

v5VarStatMasterTsa 1.3.6.1.4.1.164.3.1.6.6.2.4.1.6
This will be the V5.2 Master Switch Allocated TSA Location. It is a concatenation of SS:PP:TS of the V5.2 Master card. It indicates which is the exact port and TS allocated by the Local Exchange on the V5.2 Link. SS=IO Slot (1..12) PP=Port (01..04) TS = TS (1..31). Example: 50323 means IO-5, port-3, TS23.
OBJECT-TYPE    
  Integer32  

v5VarStatCallState 1.3.6.1.4.1.164.3.1.6.6.2.4.1.7
Call State of the Address.
OBJECT-TYPE    
  INTEGER empty(1), outOfService(2), deactive(3), actInit(4), accessAct(5), plActInit(6), plAct(7), loopback2(8), loopback1(9), loopback1A(10), null(11), pathInit(12), pathAbortReq(13), lineInfo(14), pathActive(15), blocked(16), disconnectReq(17)  

v51Ml 1.3.6.1.4.1.164.3.1.6.6.3
OBJECT IDENTIFIER    

v51MlCmdAndStatus 1.3.6.1.4.1.164.3.1.6.6.3.1
OBJECT IDENTIFIER    

v51MlTable 1.3.6.1.4.1.164.3.1.6.6.3.1.1
Variant Command and Status table.
OBJECT-TYPE    
  SEQUENCE OF  
    V51MlEntry

v51MlEntry 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1
An entry in table v51MlTable.
OBJECT-TYPE    
  V51MlEntry  

v51MlSltIdx 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1.1
Slot Index. For V5.2 this index is notApplicable.
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

v51MlPrtIdx 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1.2
This attribute indicates a unique port number of the ML having V5 interface. Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104), notApplicable(255) - for V5.2 only.
OBJECT-TYPE    
  Integer32  

v51MlCurrActiveVar 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1.3
For V5.1: the currently Active Variant Id. on this ML. For V5.2: the currently Active Variant Id. 128=none.
OBJECT-TYPE    
  Integer32 0..128  

v51MlLeActiveReqVar 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1.4
For V5.1: the Variant Id. that the Local Exchange (LE) requested to be Active on this ML. For V5.2: the Variant Id. that the Local Exchange (LE) requested to be Active. 128=none.
OBJECT-TYPE    
  Integer32 0..128  

v51MlProtocolState 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1.5
Protocol State of the ML Active Variant. - sysStartUp - an Establish request arrived to the V5.1 interface. - waitForVarId - the variant and the Interface Id were requested during the system start-up procedure. - activatePstn - activation of the PSTN Data Link was requested during the system start-up procedure. - restart1 - the PSTN restart procedure is in process. - inService - the V5.1 interface is IN SERVICE. - restart2 - the V5.1 is in AN5 state (sends restart complete to all PSTN protocols and changes status to In-Service). - restart3 - the V5.1 is in AN6 state (sends restart complete to all PSTN protocols and changes status to In-Service). - waitV5Init - this state is entered when the system's management is in In-Service state, Switch to a new Variant is received and V5.1 interface will not be restarted. - switchOver - this state is entered when the system's management is in In-Service state, Switch to a new Variant is received and V5.1 interface will be restarted. - ctrlDataLinkRel1 - this state is entered when the system's management is in In-Service state and Release Indication is received. Timer TC1 is running in this state. - ctrlDataLinkRel2 - this state is entered on reception of Release-Indication in 'restart3' state. - outOfService - the V5.1 interface is Out-of-Service. - notDefined - V5.1 is not defined for this interface.
OBJECT-TYPE    
  INTEGER sysStartUp(1), waitForVarId(2), activatePstn(3), restart1(4), inService(5), restart2(6), restart3(7), waitV5Init(8), switchOver(9), ctrlDataLinkRel1(10), ctrlDataLinkRel2(11), ctrlDataLinkRel3(12), outOfService(13), waitE1Reports(14), waitL2StartUp(15), waitLinkId(16), waitRestart(17), notDefined(18)  

v51MlUserActiveVarReq 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1.6
User Request to turn a certain Variant of the ML, to Active. This object specifies the Variant Id. requested by user to be Active. User's request is not always accepted.
OBJECT-TYPE    
  Integer32 0..127  

v51MlDeleteVarReq 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1.7
For V5.1: User Request to Delete a certain Variant of the ML. For V5.2: User Request to Delete a certain Variant This object specifies the Variant Id. requested by user to be Delete. User's request will not be accepted if the required Variant Id is Active or during Reprovision process. This object is supported only up to MP R9.
OBJECT-TYPE    
  Integer32 0..127  

v51MlSaveVariant 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1.8
User Command to Save the TmpCnfg Variant data to a certain Variant Id of the selected ML, in Current Cnfg. The value of this object specifies the target Variant Id. The data transferred should be: - for V5.1: v51VarTable and v51VarCnfgTable parameters. - for V5.2: v51VarTable, v51VarCnfgTable and v51VarCchTable parameters. Upon Set command, the MUX will initiate a Sanity-Check process first: - If successful, the actual transfer will be performed. - If warnings are detected, the user will have to perform the command again to confirm the operation. - If errors are detected, transfer will NOT be performed. This object is supported only up to MP R9.
OBJECT-TYPE    
  Integer32 0..127  

v51MlReadVariant 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1.9
User Command to Read data from a certain Variant Id of the selected ML, (in Current Cnfg) to the TmpCnfg. The value of this object specifies the source Variant Id. The data transferred should be: - for V5.1: v51VarTable and v51VarCnfgTable parameters. - for V5.2: v51VarTable, v51VarCnfgTable and v51VarCchTable parameters. The operation is valid only on existing Variants of the ML. This object is supported only up to MP R9.
OBJECT-TYPE    
  Integer32 0..127  

v51MlDeactivateVar 1.3.6.1.4.1.164.3.1.6.6.3.1.1.1.10
User Request to Deactivate a certain Variant of the ML. This object specifies the Variant Id. requested by user to be Deactivated. User can deactivate a variant having Active Request status or Active status. Deactivating the variant having Active Status wil stop the V5.1 operations on this link (for V5.2 it will stop completely the V5 activity).
OBJECT-TYPE    
  Integer32 0..127  

v51MlCnfg 1.3.6.1.4.1.164.3.1.6.6.3.2
OBJECT IDENTIFIER    

v51MlCnfgTable 1.3.6.1.4.1.164.3.1.6.6.3.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    V51MlCnfgEntry

v51MlCnfgEntry 1.3.6.1.4.1.164.3.1.6.6.3.2.1.1
An entry in table v51MlCnfgTable.
OBJECT-TYPE    
  V51MlCnfgEntry  

v51MlCnfgIdx 1.3.6.1.4.1.164.3.1.6.6.3.2.1.1.1
This attribute indicates the Idx of the Cnfg being accessed. 1..10 = Current Cnfg (data will be the same for all Current Configurations) 255 = TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

v51MlCnfgSltIdx 1.3.6.1.4.1.164.3.1.6.6.3.2.1.1.2
Slot Index. For V5.2 this index will be notApplicable(255).
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

v51MlCnfgPrtIdx 1.3.6.1.4.1.164.3.1.6.6.3.2.1.1.3
This attribute indicates a unique port number of the ML having V5 interface. Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104) NA=255 (for V5.2 only).
OBJECT-TYPE    
  Integer32  

v51MlCnfgIfId 1.3.6.1.4.1.164.3.1.6.6.3.2.1.1.4
V5.1 Interface Id.
OBJECT-TYPE    
  Integer32 0..99999999  

v51MlCnfgStartupMode 1.3.6.1.4.1.164.3.1.6.6.3.2.1.1.5
Startup Mode.
OBJECT-TYPE    
  INTEGER sync(2), async(3)  

v51MlCnfgReprovision 1.3.6.1.4.1.164.3.1.6.6.3.2.1.1.6
Reprovision Support. - no : no reprovision support (=default) - yes: reprovision is supported.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

v51MlCnfgUnblockIoPorts 1.3.6.1.4.1.164.3.1.6.6.3.2.1.1.7
Unblock IO Ports on Startup. - disabled - disable sending Unblock request on restart - enabled - request unblock of all IO ports ON RESTART (=default).
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

v51MlCnfgRestartComplete 1.3.6.1.4.1.164.3.1.6.6.3.2.1.1.8
Send Restart Complete. - uponLeRestart - after receiving restart from the other side. - uponPstnProtocolAck - after receiving restart ack from PSTN protocol (=default).
OBJECT-TYPE    
  INTEGER uponLeRestart(2), uponPstnProtocolAck(3)  

v51MlCnfgV52Application 1.3.6.1.4.1.164.3.1.6.6.3.2.1.1.9
The V5.2 Application of the Mux. notApplicable - for Agents that don't support this object. none - V5.2 is not used in the Mux. endPoint - this V5.2 Application transfers voice of Analog Voice and ISDN cards of the Mux, to/from V5.2 Local Exchange. exchangePoint - this V5.2 Application exchanges voice of ML cards (coming from other devices) to/from V5.2 Local Exchange.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), endPoint(3), exchangePoint(4)  

v51AccessPort 1.3.6.1.4.1.164.3.1.6.6.4
OBJECT IDENTIFIER    

v51IoCnfgTable 1.3.6.1.4.1.164.3.1.6.6.4.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
OBJECT-TYPE    
  SEQUENCE OF  
    V51IoCnfgEntry

v51IoCnfgEntry 1.3.6.1.4.1.164.3.1.6.6.4.1.1
An entry in table v51IoCnfgTable.
OBJECT-TYPE    
  V51IoCnfgEntry  

v51IoCnfgIdx 1.3.6.1.4.1.164.3.1.6.6.4.1.1.1
This attribute indicates the Idx of the Cnfg being accessed. 1..10 = Current Cnfg (data will be the same for all Current Configurations) 255 = TmpCnfg.
OBJECT-TYPE    
  Integer32 1..255  

v51IoCnfgSltIdx 1.3.6.1.4.1.164.3.1.6.6.4.1.1.2
Slot Index
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

v51IoCnfgPrtIdx 1.3.6.1.4.1.164.3.1.6.6.4.1.1.3
This attribute indicates a unique port number of the Io having V5 interface. Valid values: exPrt1 (1)..exPrt16 (16)
OBJECT-TYPE    
  Integer32  

v51IoCnfgSType 1.3.6.1.4.1.164.3.1.6.6.4.1.1.4
This object indicates if S Type Signaling will be used by this ISDN port (yes/no). notApplicable - for PSTN ports.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

v51IoCnfgFType 1.3.6.1.4.1.164.3.1.6.6.4.1.1.5
This object indicates if F Type Signaling will be used by this ISDN port (yes/no). notApplicable - for PSTN ports.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

v51IoCnfgPType 1.3.6.1.4.1.164.3.1.6.6.4.1.1.6
This object indicates if P Type Signaling will be used by this ISDN port (yes/no). notApplicable - for PSTN ports.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

ip2If 1.3.6.1.4.1.164.3.1.6.7
OBJECT IDENTIFIER    

ip2IfTable 1.3.6.1.4.1.164.3.1.6.7.1
Channels Configuration Table.
OBJECT-TYPE    
  SEQUENCE OF  
    Ip2IfEntry

ip2IfEntry 1.3.6.1.4.1.164.3.1.6.7.1.1
Application layer configuration per link
OBJECT-TYPE    
  Ip2IfEntry  

ip2IfChannelIndex 1.3.6.1.4.1.164.3.1.6.7.1.1.1
The channel index, which is actualy the bundle ID.
OBJECT-TYPE    
  Integer32  

ip2IfRowStatus 1.3.6.1.4.1.164.3.1.6.7.1.1.2
This parameter allows NMS to create/delete entries of this table.
OBJECT-TYPE    
  RowStatus  

ip2IfOperStatus 1.3.6.1.4.1.164.3.1.6.7.1.1.3
The actual link status. remoteFail - No Rx. localFail - No Tx. unavailable - No echo replay or replay with invalid code or when connection is in Test state. valiodationFail - Connection is in not valid state. standby - offline (can be in pre-sync mode). tdmFail - oper status is down cause of failure in the tdm. hwMismatch - the bundle exists on a card that is not installed or has a different type than the programmed card.
OBJECT-TYPE    
  INTEGER down(2), up(3), disabled(4), remoteFail(5), localFail(6), unavailable(7), validationFail(8), standby(9), tdmFail(10), hwMismatch(11)  

ip2IfAdminStatus 1.3.6.1.4.1.164.3.1.6.7.1.1.4
The desired state of the link.
OBJECT-TYPE    
  INTEGER down(2), up(3)  

ip2IfDestAddr 1.3.6.1.4.1.164.3.1.6.7.1.1.5
The destination IP address.
OBJECT-TYPE    
  IpAddress  

ip2IfNextHop 1.3.6.1.4.1.164.3.1.6.7.1.1.6
The next hop to which the frame should be sent. Default value - 0.0.0.0. Upon setting the default value the frame is sent to the default Gateway.
OBJECT-TYPE    
  IpAddress  

ip2IfDestPort 1.3.6.1.4.1.164.3.1.6.7.1.1.7
The destination Bundle at the far-end device.
OBJECT-TYPE    
  Integer32  

ip2IfMacAddr 1.3.6.1.4.1.164.3.1.6.7.1.1.8
The Destination MAC address of the next hop or destination station.
OBJECT-TYPE    
  MacAddress  

ip2IfJitterBuffer 1.3.6.1.4.1.164.3.1.6.7.1.1.9
The maximum cell arrival jitter in 10 usec that the reassembly process will tolerate in the cell stream, without producing errors on the CBR service interface. Default value - 100. For KM2100: KML.11 - The range that will be used is 3...300 msec in steps of 1 msec. For Vmux: The range that will be used is 20...300 msec in steps of 10 msec.
OBJECT-TYPE    
  Integer32  

ip2IfTos 1.3.6.1.4.1.164.3.1.6.7.1.1.10
The TOS (Type of Service) value: 0..255.
OBJECT-TYPE    
  Integer32  

ip2IfTDMBytesInFrame 1.3.6.1.4.1.164.3.1.6.7.1.1.11
The number of TDM bytes to be placed in a single IP frame payload.
OBJECT-TYPE    
  Integer32  

ip2IfVlanSupport 1.3.6.1.4.1.164.3.1.6.7.1.1.12
VLAN support (Tagging). no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame.
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

ip2IfVlanIdentifier 1.3.6.1.4.1.164.3.1.6.7.1.1.13
VLAN ID.
OBJECT-TYPE    
  Integer32  

ip2IfVlanFramePriority 1.3.6.1.4.1.164.3.1.6.7.1.1.14
VLAN Frame priority.
OBJECT-TYPE    
  Integer32  

ip2IfExitPort 1.3.6.1.4.1.164.3.1.6.7.1.1.15
This object determines to which external port the traffic will be sent. auto - the device will decide automatically the exit port. If there is an option for Tx via more than one ETH card then use ext1 (1) and ext2(2) for ETH card #1 (ex. LAN1 or Ggabit-ETH1) and use card2Ext1(5) and card2Ext2(6) for card #2 (ex. LAN1 or Ggabit-ETH1). In Vmux-110 ext5 is used for ETH-NET, ext7 is used for Serial Link.
OBJECT-TYPE    
  INTEGER notApplicable(1), ext1(2), ext2(3), auto(4), card2Ext1(5), card2Ext2(6), ext5(7), ext7(8)  

ip2IfVoiceOos 1.3.6.1.4.1.164.3.1.6.7.1.1.16
Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
OBJECT-TYPE    
  OCTET STRING  

ip2IfDataOos 1.3.6.1.4.1.164.3.1.6.7.1.1.17
Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
OBJECT-TYPE    
  OCTET STRING  

ip2IfBundleUsage 1.3.6.1.4.1.164.3.1.6.7.1.1.18
The Bundle Resource usage in Kbps.
OBJECT-TYPE    
  Integer32  

ip2IfOAM 1.3.6.1.4.1.164.3.1.6.7.1.1.19
This parameter determine the OAM configuration. The LSB (Bit 0 the most right one) is used for OAM connectivity. Values: 0 = disable, 1= enable.
OBJECT-TYPE    
  OCTET STRING  

ip2IfTDMoIpMode 1.3.6.1.4.1.164.3.1.6.7.1.1.20
The TDMoIP Mode configuration. Static- means TS can Tx any time. dynamicLES - means TS can Tx only when line is enabled according to LES protocol. dynamicCAS - means TS can Tx only when line is enabled according to CAS protocol. cesOverIp - use for information that this bundle is used for CES Over IP. voiceOverMpls - Voice over Multi Protocol Label Switching.
OBJECT-TYPE    
  INTEGER notApplicable(1), static(2), dynamicLES(3), dynamicCAS(4), cesOverIp(5), voiceOverMpls(6)  

ip2IfTimeElapsed 1.3.6.1.4.1.164.3.1.6.7.1.1.21
The number of seconds that have elapsed since the beginning of the current error-measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value.
OBJECT-TYPE    
  Integer32 0..899  

ip2IfValidIntervals 1.3.6.1.4.1.164.3.1.6.7.1.1.22
The number of previous intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online.
OBJECT-TYPE    
  Integer32 0..96  

ip2IfFarEndType 1.3.6.1.4.1.164.3.1.6.7.1.1.23
This object defines the type of the Far-End device. This data is important for signaling.
OBJECT-TYPE    
  INTEGER notApplicable(1), e1(2), t1Esf(3), t1D4(4), fxs(5)  

ip2IfRdnState 1.3.6.1.4.1.164.3.1.6.7.1.1.24
This object defines the role this bundle plays in the redundancy scheme: none(2) - means this bundle is not part of redundancy pair. primary/ secondary - means this bundle is not part of redundancy pair, and that is the primary bundle or the secondary bunle.
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), primary(3), secondary(4)  

ip2IfSourceAddr 1.3.6.1.4.1.164.3.1.6.7.1.1.25
Source IP Address of the bundle.
OBJECT-TYPE    
  IpAddress  

ip2IfBandWidth 1.3.6.1.4.1.164.3.1.6.7.1.1.26
Number of Time Slots in The Bundle. For T1 the value will be: 1..24 For E1 the value will be: 1..31 For T3 the value will be: 1..84 For E3 the value will be: 1..63 This parameter is required for devices like Emux where the bandwidth of the bundles is unknown. The bundles that are received should be transmitted without any change in the bandwidth. It is the user's responsibility to enter the correct bandwidth.
OBJECT-TYPE    
  Integer32  

ip2IfMeasuredSilence 1.3.6.1.4.1.164.3.1.6.7.1.1.27
This object shows the percentage of Silence that was measured by the device for the current bundle. Relevant values: 0..100, 255. Default value is 50. 0 means that there is no silence on the line. 100 means that there is only silence. In this case, there might be no traffic. 255 - value for not applicable or unknown.
OBJECT-TYPE    
  Integer32  

ip2IfPayloadType 1.3.6.1.4.1.164.3.1.6.7.1.1.28
This object defines the TDMoIP payload type.
OBJECT-TYPE    
  INTEGER notApplicable(1), data(2), voice(3), voiceAndCas(4)  

ip2IfProtocolVersion 1.3.6.1.4.1.164.3.1.6.7.1.1.29
This object defines the TDMoIP protocol Version.
OBJECT-TYPE    
  INTEGER notApplicable(1), v1(2), v2(3)  

ip2IfTdmBackUpNextHop 1.3.6.1.4.1.164.3.1.6.7.1.1.30
Defines the TDM bundle default router in case there was a switch from the Primary Link (for example an ETH port) to a TDM backup Link like E1, T1 or Serial Link. This parameter is relevant only when a Backup Link is configured. When a Backup Link is not configured the value will be: 0.0.0.0
OBJECT-TYPE    
  IpAddress  

ip2IfOosTxEnable 1.3.6.1.4.1.164.3.1.6.7.1.1.31
This object defines whether OOS will be Transmitted. Note that for IPmux1000 the Lbit is always sent, but the OOS will be sent according to user selection in this parameter.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfConnCheckPktFrequency 1.3.6.1.4.1.164.3.1.6.7.1.1.32
Time in sec. between 2 Bundle Connectivity Check packets. Valid values: 0..60. 0 = Not Applicable.
OBJECT-TYPE    
  Integer32  

ip2IfConnPktTimeOutCycles 1.3.6.1.4.1.164.3.1.6.7.1.1.33
No. of cycles the agent will send Bundle Connectivity packets without receiving a response from the remote device before declaring that the bundle connection to the remote side is down - Time Out. Valid values: 0..5. 0 = Not Applicable.
OBJECT-TYPE    
  Integer32  

ip2IfMfRelay 1.3.6.1.4.1.164.3.1.6.7.1.1.34
Multi Frequency Signaling Detection.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfTxGain 1.3.6.1.4.1.164.3.1.6.7.1.1.35
Transmit gain in dBm.
OBJECT-TYPE    
  Integer32  

ip2IfSuperTandem 1.3.6.1.4.1.164.3.1.6.7.1.1.36
The Super Tandem feature provides end to end compression over multiple hops, solving the double compression problem detected in Voice compressing systems. The Super Tandem allows transmission of compressed voice between a few Vmux 2100 hubs, and eliminates the need to decompress an recompress it over each voice card and PBX, thus improving voice quality and reducing delay.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfSrcPort 1.3.6.1.4.1.164.3.1.6.7.1.1.37
The source Bundle at the local device, this parameter used for cases where there is no match between ip2IfChannelIndex and the Source Bundle ID.
OBJECT-TYPE    
  Integer32  

ip2IfModemCalls 1.3.6.1.4.1.164.3.1.6.7.1.1.38
This MIB object shows whether Modem Calls are enabled via the bundle. relay option (3) means that the bundle will send to the network only modulated data.
OBJECT-TYPE    
  INTEGER disable(2), enable(3), relay(4)  

ip2IfMinPulseWidth 1.3.6.1.4.1.164.3.1.6.7.1.1.39
Indicates the minimum width in milliseconds of the MF (Multi Frequency) tone transmitted by the switch. Valid values: 45-300 msec. notApplicable=0.
OBJECT-TYPE    
  Integer32  

ip2IfMinPowerLevel 1.3.6.1.4.1.164.3.1.6.7.1.1.40
Indicates the minimum power level in dBm of the MF (Multi Frequency) tone transmitted by the switch. Valid values: -1...-35 dBm.
OBJECT-TYPE    
  Integer32  

ip2IfEchoCanceler 1.3.6.1.4.1.164.3.1.6.7.1.1.41
Echo canceler activation.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

ip2IfCodingLaw 1.3.6.1.4.1.164.3.1.6.7.1.1.42
This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links.
OBJECT-TYPE    
  INTEGER aLAW(1), uLAW(2)  

ip2IfCustomToneDetect 1.3.6.1.4.1.164.3.1.6.7.1.1.43
Custom Tone Detection (COT) is a Control operation of a 2Khz tone detector. This tone is sent between PBX devices in order to check that the line status is OK. When the COT is enabled the device will not compress/decompress the tone. In this case, if the tone is initiated by the local PBX, the Device runs a 2Khz detector tone and once detected by the Remote Device, if the COT is enabled in the Remote Device, the Remote Device will generate a 2khz tone to the remote PBX.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ip2IfCallerIdDelay 1.3.6.1.4.1.164.3.1.6.7.1.1.44
Time in msec between CLID (Caller ID) signal detection on the line and CLID signal transmission. The CLID must be sent between ringing signals and the value of the delay is used for synchronizing the CLID transmission with the ringing signals transmission. Valid values: 0 - 3000 msec.
OBJECT-TYPE    
  Integer32  

ip2IfConnectivityMode 1.3.6.1.4.1.164.3.1.6.7.1.1.45
This MIB object shows whether to send Pings or OAM frames over the bundle.
OBJECT-TYPE    
  INTEGER ping(2), oam(3)  

ip2IfMfcSpoofing 1.3.6.1.4.1.164.3.1.6.7.1.1.53
This MIB object defines whether the MFC (Multi Frequency Compelled) protocol spoofing will exist in the bundle. When the MFC Spoofing is used, the Local and Remote PBXs will send MFC Signaling to each other. The Vmuxes between the PBXs will send proprietary signaling to each other. They will however create and send MFC tones to their local PBX. The PBXs will not know that the actual signaling was not sent from a PBX but from a Vmux.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfToneAckInterval 1.3.6.1.4.1.164.3.1.6.7.1.1.54
Time Interval in milli seconds from the time a Vmux sends tone/s to a local PBX until it receives an acknowledgement from this PBX. Valid values: 60...400 in steps of 20. Default: 80.
OBJECT-TYPE    
  Integer32  

ip2IfNoiseLevelForVAD 1.3.6.1.4.1.164.3.1.6.7.1.1.56
This object defines the Level of Noise on the line, the Voice Activation Detector (VAD) will have to handle.
OBJECT-TYPE    
  INTEGER low(2), high(3)  

ip2IfTDMFrameBytes 1.3.6.1.4.1.164.3.1.6.7.2
The number of TDM bytes to be placed in a single IP frame payload.
OBJECT-TYPE    
  Integer32  

ip2IfTosValue 1.3.6.1.4.1.164.3.1.6.7.3
The TOS value to write in the IP frame.
OBJECT-TYPE    
  Integer32  

ip2IfVlanTagging 1.3.6.1.4.1.164.3.1.6.7.4
VLAN support. no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ip2IfVlanID 1.3.6.1.4.1.164.3.1.6.7.5
VLAN ID.
OBJECT-TYPE    
  Integer32  

ip2IfVlanPriority 1.3.6.1.4.1.164.3.1.6.7.6
Frame priority.
OBJECT-TYPE    
  Integer32  

ip2IfStatTable 1.3.6.1.4.1.164.3.1.6.7.7
Channels (Bundles) Statistics Table.
OBJECT-TYPE    
  SEQUENCE OF  
    Ip2IfStatEntry

ip2IfStatEntry 1.3.6.1.4.1.164.3.1.6.7.7.1
IP Statistics per bundle
OBJECT-TYPE    
  Ip2IfStatEntry  

ip2IfStatChIndex 1.3.6.1.4.1.164.3.1.6.7.7.1.1
The channel index, which is actualy the bundle ID.
OBJECT-TYPE    
  Integer32  

ip2IfStatSeqErrors 1.3.6.1.4.1.164.3.1.6.7.7.1.2
Number of times that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state.
OBJECT-TYPE    
  Integer32  

ip2IfStatBufUnderflows 1.3.6.1.4.1.164.3.1.6.7.7.1.3
Number of buffer underflows. This records the count of the number of times the Receive (Eth to TDM) buffer underflows. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted.
OBJECT-TYPE    
  Integer32  

ip2IfStatBufOverflows 1.3.6.1.4.1.164.3.1.6.7.7.1.4
Number of buffer overflows. This records the count of the number of times the Receive (Eth to TDM) buffer overflows.
OBJECT-TYPE    
  Integer32  

ip2IfStatTxOnTimeInterval 1.3.6.1.4.1.164.3.1.6.7.7.1.5
Number of frames that were transmitted due to time interval elapse. The user can choose to Tx the Frame when it reaches the Max size or when the packetizing time interval elapses. The packetizing time interval is the interval in msec that it takes to build a Max. size frame.
OBJECT-TYPE    
  Counter32  

ip2IfStatTxOnMaxSize 1.3.6.1.4.1.164.3.1.6.7.7.1.6
Number of frames that were transmitted due to reaching max. frame size. The user can choose to Tx the Frame when it reaches the Max size or when the packetizing time interval elapses.
OBJECT-TYPE    
  Counter32  

ip2IfStatRxSignaling 1.3.6.1.4.1.164.3.1.6.7.7.1.7
Number of signaling frames that were received.
OBJECT-TYPE    
  Counter32  

ip2IfStatRxVoice 1.3.6.1.4.1.164.3.1.6.7.7.1.8
Number of voice frames that were received.
OBJECT-TYPE    
  Counter32  

ip2IfStatRxHdlc 1.3.6.1.4.1.164.3.1.6.7.7.1.9
Number of HDLC frames that were received.
OBJECT-TYPE    
  Counter32  

ip2IfStatTxSignaling 1.3.6.1.4.1.164.3.1.6.7.7.1.10
Number of signaling frames that were transmitted.
OBJECT-TYPE    
  Counter32  

ip2IfStatTxVoice 1.3.6.1.4.1.164.3.1.6.7.7.1.11
Number of voice frames that were transmitted.
OBJECT-TYPE    
  Counter32  

ip2IfStatTxHdlc 1.3.6.1.4.1.164.3.1.6.7.7.1.12
Number of HDLC frames that were transmitted.
OBJECT-TYPE    
  Counter32  

ip2IfStatRdnFlip 1.3.6.1.4.1.164.3.1.6.7.7.1.13
Number of redundancy flips occured. This parameter counts only flips from this bundle to the other bundle in the redundancy couple.
OBJECT-TYPE    
  Counter32  

ip2IfRateLimit 1.3.6.1.4.1.164.3.1.6.7.8
The maximum rate permitted to transfer via the network portin Mbps.
OBJECT-TYPE    
  Integer32  

ip2IfPortTable 1.3.6.1.4.1.164.3.1.6.7.9
Port Table.
OBJECT-TYPE    
  SEQUENCE OF  
    Ip2IfPortEntry

ip2IfPortEntry 1.3.6.1.4.1.164.3.1.6.7.9.1
Application layer configuration per Port
OBJECT-TYPE    
  Ip2IfPortEntry  

ip2IfPortIndex 1.3.6.1.4.1.164.3.1.6.7.9.1.1
The Port index, which is actualy the ifIndex.
OBJECT-TYPE    
  Integer32  

ip2IfPortUsage 1.3.6.1.4.1.164.3.1.6.7.9.1.2
This parameter indicates the usage of the port (percents).
OBJECT-TYPE    
  Integer32  

ip2IfPortMask 1.3.6.1.4.1.164.3.1.6.7.9.1.3
This parameter defines whether Agent will mask port's alarms and statistics or not.
OBJECT-TYPE    
  INTEGER notApplicable(1), dontMask(2), mask(3)  

ip2IfPortTotalThroughput 1.3.6.1.4.1.164.3.1.6.7.9.1.4
This parameter indicates the total Throughput of the port in bps.
OBJECT-TYPE    
  Integer32  

ip2IfCurrentStatTable 1.3.6.1.4.1.164.3.1.6.7.10
Channels (Bundles) Current Statistics Table.
OBJECT-TYPE    
  SEQUENCE OF  
    Ip2IfCurrentStatEntry

ip2IfCurrentStatEntry 1.3.6.1.4.1.164.3.1.6.7.10.1
IP Current Statistics per bundle
OBJECT-TYPE    
  Ip2IfCurrentStatEntry  

ip2IfCurrentStatSeqErrors 1.3.6.1.4.1.164.3.1.6.7.10.1.1
Number of times that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state in the current interval.
OBJECT-TYPE    
  Counter32  

ip2IfCurrentStatBufUnderflows 1.3.6.1.4.1.164.3.1.6.7.10.1.2
Number of buffer underflows in the current interval. This records the count of the number of times the Receive (Eth to TDM) buffer underflows in the current interval. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted.
OBJECT-TYPE    
  Counter32  

ip2IfCurrentStatBufOverflows 1.3.6.1.4.1.164.3.1.6.7.10.1.3
Number of buffer overflows in the current interval. This records the count of the number of times the Receive (Eth to TDM) buffer overflows in the current interval.
OBJECT-TYPE    
  Counter32  

ip2IfCurrentStatMaxDelayVar 1.3.6.1.4.1.164.3.1.6.7.10.1.4
The maximum size of the buffer (in 10's of usec) for the current interval.
OBJECT-TYPE    
  Integer32  

ip2IfIntervalStatTable 1.3.6.1.4.1.164.3.1.6.7.11
Channels (Bundles) Interval Statistics Table.
OBJECT-TYPE    
  SEQUENCE OF  
    Ip2IfIntervalStatEntry

ip2IfIntervalStatEntry 1.3.6.1.4.1.164.3.1.6.7.11.1
IP Interval Statistics per bundle
OBJECT-TYPE    
  Ip2IfIntervalStatEntry  

ip2IfIntervalStatIndex 1.3.6.1.4.1.164.3.1.6.7.11.1.1
The Interval index, which is actualy the Interval number.
OBJECT-TYPE    
  Integer32  

ip2IfIntervalStatSeqErrors 1.3.6.1.4.1.164.3.1.6.7.11.1.2
Number of times that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state in the selected interval.
OBJECT-TYPE    
  Counter32  

ip2IfIntervalStatBufUnderflows 1.3.6.1.4.1.164.3.1.6.7.11.1.3
Number of buffer underflows in the selected interval. This records the count of the number of times the Receive (Eth to TDM) buffer underflows in the selected interval. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted.
OBJECT-TYPE    
  Counter32  

ip2IfIntervalStatBufOverflows 1.3.6.1.4.1.164.3.1.6.7.11.1.4
Number of buffer overflows in the selected interval. This records the count of the number of times the Receive (Eth to TDM) buffer overflows in the selected interval.
OBJECT-TYPE    
  Counter32  

ip2IfIntervalStatMaxDelayVar 1.3.6.1.4.1.164.3.1.6.7.11.1.5
The maximum size of the buffer (in 10's of usec) in the selected interval.
OBJECT-TYPE    
  Integer32  

ip2IfLogEvents 1.3.6.1.4.1.164.3.1.6.7.12
This parameter defines whether all Jitter Buffer and Sequence Number events will enter to Log File, or enter those events to Log file in one minute steps.
OBJECT-TYPE    
  INTEGER notApplicable(1), all(2), oneMinStep(3)  

ip2IfEthSwitchMode 1.3.6.1.4.1.164.3.1.6.7.13
This parameter defines whether Eth Switch is in VLAN Tagged mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), unTagged(2), tagged(3)  

voipWanGen 1.3.6.1.4.1.164.3.1.7
OBJECT IDENTIFIER    

voipCardConfig 1.3.6.1.4.1.164.3.1.7.1
The value of this object determines the VOIP card configuration. Bit 0 (LSB): if 1 - a GK exists. If 0 - no GK exists in this card. The other bits may be used in the future.
OBJECT-TYPE    
  Integer32  

gkGenTable 1.3.6.1.4.1.164.3.1.7.2
General parameters for the VOIP GateKeeper.
OBJECT-TYPE    
  SEQUENCE OF  
    GkGenEntry

gkGenEntry 1.3.6.1.4.1.164.3.1.7.2.1
An entry in table gkGenTable.
OBJECT-TYPE    
  GkGenEntry  

gkGenCallMode 1.3.6.1.4.1.164.3.1.7.2.1.1
This parameters shows whether the calls will go through the GK (routed) or whether the calls will be direct from Endpoint to Endpoint without involving the GK (direct).
OBJECT-TYPE    
  INTEGER direct(2), routed(3), notApplicable(255)  

gkGenMaxConnections 1.3.6.1.4.1.164.3.1.7.2.1.2
MAX no. of connections enabled by the GK to take place simultaneously. If the MAX no. of calls is exceeded, a busy signal will be returned.
OBJECT-TYPE    
  Integer32  

gkGenDefaultDistance 1.3.6.1.4.1.164.3.1.7.2.1.3
The Distance allowed for endpoints that are registered dynamically.
OBJECT-TYPE    
  Integer32  

gkGenOutOfZoneDist 1.3.6.1.4.1.164.3.1.7.2.1.4
The Distance allowed for an out of zone endpoint that is making a call through the gatekeeper.
OBJECT-TYPE    
  Integer32  

gkGenCallAcceptPolicy 1.3.6.1.4.1.164.3.1.7.2.1.5
Defines the policy concerning the incoming phone calls. The importance of this parameter is for bidding and security matters. Accept All - all the incoming calls are accepted. Registered Only - the calls are accepted from the predefined endpoints only, which are endpoints that have previously registered with the gatekeeper. Predefined Only - with this policy only the calls from the statically registered endpoints can be accepted.
OBJECT-TYPE    
  INTEGER acceptAll(2), registeredOnly(3), predefinedOnly(4)  

gkGenIrqInterval 1.3.6.1.4.1.164.3.1.7.2.1.6
In order for the Gatekeeper to determine if an endpoint is turned off, or has otherwise entered a failure mode, the Gatekeeper may use the Information Request (IRQ) to poll the endpoints at the certain interval (in seconds). THE IRQ INTERVAL controls the frequency the gk sends IRQ messages. This message is sent to all on-line endpoints registered as dynamic in order to verify they are really on-line. This is done to detect terminals that shut off without sending the required URQ message that notifies the gk that they are no longer on-line. Endpoints failing to respond too many times have their dynamic properties unregistered. Choosing the desired interval should take into account the following factors : IRQ messages add to the traffic already present over the network and the shorter the interval the more IRQ messages will be sent. On the other hand the longer the delay the longer it will take for the gk to detect dynamic registrations that have ceased to actually be on-line. Note that the IRQ interval relates to each endpoint and the actual number of the IRQ messages the gk will create should be multiplied by the number of endpoints registered dynamically.
OBJECT-TYPE    
  Integer32  

gkGenQ931Port 1.3.6.1.4.1.164.3.1.7.2.1.7
Q.931 Port no.
OBJECT-TYPE    
  Integer32  

gkGenRasPort 1.3.6.1.4.1.164.3.1.7.2.1.8
RAS Port no.
OBJECT-TYPE    
  Integer32  

gkGenRegPolicy 1.3.6.1.4.1.164.3.1.7.2.1.9
Policy of dynamic registrations in the Gatekeeper. The GK will act according to the following policies: Accept All - The GK will enable all requesting endpoints to register dynamically. Predefined Only - The GK will enable registration of endpoints that were registered previously via static registration. Registration Reject - No endpoint may register dynamically.
OBJECT-TYPE    
  INTEGER acceptAll(2), predefinedOnly(3), registrationReject(4)  

gkGenZoneId 1.3.6.1.4.1.164.3.1.7.2.1.10
Zone Identifier: 1 or 2 digits, (0-9)(1-9).
OBJECT-TYPE    
  OCTET STRING  

gkEndpTable 1.3.6.1.4.1.164.3.1.7.3
Table containing the Endpoints that are registered (statically & Dynamically) with the current GK.
OBJECT-TYPE    
  SEQUENCE OF  
    GkEndpEntry

gkEndpEntry 1.3.6.1.4.1.164.3.1.7.3.1
An entry in table gkEndpTable.
OBJECT-TYPE    
  GkEndpEntry  

gkEndpAliasTag 1.3.6.1.4.1.164.3.1.7.3.1.1
Alias Tag of the Endpoint.
OBJECT-TYPE    
  MmAliasTag  

gkEndpAlias 1.3.6.1.4.1.164.3.1.7.3.1.2
Alias of the Endpoint.
OBJECT-TYPE    
  MmAliasAddress  

gkEndpRowStatus 1.3.6.1.4.1.164.3.1.7.3.1.3
The row status of the entry. This object is required to create or delete rows remotely by a manager.
OBJECT-TYPE    
  RowStatus  

gkEndpAddressTag 1.3.6.1.4.1.164.3.1.7.3.1.4
Address Tag of Endpoint.
OBJECT-TYPE    
  MmTAddressTag  

gkEndpAddress 1.3.6.1.4.1.164.3.1.7.3.1.5
Address of Endpoint.
OBJECT-TYPE    
  TAddress  

gkEndpID 1.3.6.1.4.1.164.3.1.7.3.1.6
Endpoint Identifier.
OBJECT-TYPE    
  MmEndpointID  

gkEndpType 1.3.6.1.4.1.164.3.1.7.3.1.7
This parameter shows whether the current endpoint is a GW or Terminal or any other type of H.323 endpoint.
OBJECT-TYPE    
  MmH323EndpointType  

gkEndpQ931Port 1.3.6.1.4.1.164.3.1.7.3.1.8
Q.931 Port no.
OBJECT-TYPE    
  Integer32  

gkEndpDistance 1.3.6.1.4.1.164.3.1.7.3.1.9
Distance from the current endpoint to the GateKeeper with which it is Registered.
OBJECT-TYPE    
  Integer32  

gkEndpRegMode 1.3.6.1.4.1.164.3.1.7.3.1.10
This parameter shows whether the Endpoint Registered Dynamically or Statically.
OBJECT-TYPE    
  INTEGER dynamic(2), static(3)  

gkEndpSetOnline 1.3.6.1.4.1.164.3.1.7.3.1.11
This parameter shows whether the endpoint will always be online or whether it will be on line upon Dynamic Registration only.
OBJECT-TYPE    
  INTEGER uponDynamicReg(2), always(3)  

gkEndpStatus 1.3.6.1.4.1.164.3.1.7.3.1.12
This parameter shows whether the endpoint is currently online.
OBJECT-TYPE    
  INTEGER online(2), offline(3)  

gkNeighbTable 1.3.6.1.4.1.164.3.1.7.4
Table of GateKeepers that are Neighbors of the current Gatekeeper.
OBJECT-TYPE    
  SEQUENCE OF  
    GkNeighbEntry

gkNeighbEntry 1.3.6.1.4.1.164.3.1.7.4.1
An entry in table gkNeighbTable.
OBJECT-TYPE    
  GkNeighbEntry  

gkNeighbAddressTag 1.3.6.1.4.1.164.3.1.7.4.1.1
Tag of GK or GW address.
OBJECT-TYPE    
  MmTAddressTag  

gkNeighbAddress 1.3.6.1.4.1.164.3.1.7.4.1.2
Address of GK or GW.
OBJECT-TYPE    
  TAddress  

gkNeighbRowStatus 1.3.6.1.4.1.164.3.1.7.4.1.3
The row status of the entry. This object is required to create or delete rows remotely by a manager.
OBJECT-TYPE    
  RowStatus  

gkNeighbLeadingAlias 1.3.6.1.4.1.164.3.1.7.4.1.4
This is the Leading Alias Address (Zone Prefix) that will be dialed in order to reach the specific neighbor.
OBJECT-TYPE    
  MmAliasAddress  

gkNeighbDistance 1.3.6.1.4.1.164.3.1.7.4.1.5
Distance between the local GateKeeper and the Neighbor GateKeeper.
OBJECT-TYPE    
  Integer32  

gkNeighbDescription 1.3.6.1.4.1.164.3.1.7.4.1.6
ASCII String Description for identifying the Neighbor.
OBJECT-TYPE    
  MmGatekeeperID  

gwGenTable 1.3.6.1.4.1.164.3.1.7.5
General parameters for the VOIP GateWay.
OBJECT-TYPE    
  SEQUENCE OF  
    GwGenEntry

gwGenEntry 1.3.6.1.4.1.164.3.1.7.5.1
An entry in table gwGenTable.
OBJECT-TYPE    
  GwGenEntry  

gwGenGwId 1.3.6.1.4.1.164.3.1.7.5.1.1
A character string of up to 20 characters identifying the gateway.
OBJECT-TYPE    
  MmEndpointID  

gwGenQ931Port 1.3.6.1.4.1.164.3.1.7.5.1.2
The Q.931 port no. of the Gateway.
OBJECT-TYPE    
  Integer32  

gwGenRasPort 1.3.6.1.4.1.164.3.1.7.5.1.3
The RAS port no. of the Gateway.
OBJECT-TYPE    
  Integer32  

gwGenMode 1.3.6.1.4.1.164.3.1.7.5.1.4
GW Mode: disable - The GW is not activated. cvsIp - CVS is a Compressed Voice System. The GW will compress voice calls at a ratio of 16 to 1. 16 time slots of E1/T1 will be compressed into 1 E1/T1 time slot. When this mode is used the Gateway can communicate directly with another Gateway without a Gatekeeper. standard - This mode includes a Gateway & a Gatekeeper.
OBJECT-TYPE    
  INTEGER disable(2), cvsIp(3), standard(4), notApplicable(255)  

gwGenVoipExtension 1.3.6.1.4.1.164.3.1.7.5.1.5
This is the extension number of the VOIP protocol. It is used for the Voice card to identify the calls made through the VoIP card. The user may choose an arbitrary value for this field, the only restriction is that there must be no other entity registered with the same extension number.
OBJECT-TYPE    
  Integer32  

gwGenRemGwAddress 1.3.6.1.4.1.164.3.1.7.5.1.6
Defines the remote gateway address (IP + port). It is important for gateway to gateway connection.
OBJECT-TYPE    
  TAddress  

gwGenMaxConnections 1.3.6.1.4.1.164.3.1.7.5.1.7
MAX no. of connections enabled by the GW.
OBJECT-TYPE    
  Integer32  

gwGenTOS 1.3.6.1.4.1.164.3.1.7.5.1.8
Type of Service. The BIT Format is consistent with the IP standard: +-----+-----+-----+-----+-----+-----+-----+-----+ | | | | | PRECEDENCE | TYPE OF SERVICE | 0 | | | | | +-----+-----+-----+-----+-----+-----+-----+-----+ 0 1 2 3 4 5 6 7 At present, only 1 BYTE will be used, bits 0 (MSB) - 7 (LSB). The precedence consists of 3 BITS (0-2): 111 - Network Control 110 - Internetwork Control 101 - CRITIC/ECP 100 - Flash Override 011 - Flash 010 - Immediate 001 - Priority 000 - Routine The TOS values BITS (3-5): Bit 3 is the Delay: 0 = Normal Delay, 1 = Low Delay. Bit 4 is the Throughput: 0 = Normal Throughput, 1 = High Throughput. Bit 5:is the Reliability: 0 = Normal Reliability, 1 = High Reliability. Bits 6 & 7 are for future use and their current value is 0.
OBJECT-TYPE    
  OCTET STRING  

gwGenBackupGkAddr 1.3.6.1.4.1.164.3.1.7.5.1.9
Defines the backup gatekeeper address (IP + port). When the backup GK is active, all the calls will be routed to it and it will be responsible for their address translation. The first GK address is defined in the standard H.341 MIB.
OBJECT-TYPE    
  TAddress  

gwGenTimeToRegister 1.3.6.1.4.1.164.3.1.7.5.1.10
The GW should register every 'Time to Register' seconds with the GK. The 'Time to Register' range is from 0 to 900 seconds in intervals of 60 seconds. 0 means Never. When the GK becomes active the Gateways that are up can register so that the GK has an updated list of active Registered Gateways.
OBJECT-TYPE    
  Integer32  

radH245ConfigTable 1.3.6.1.4.1.164.3.1.7.6
This table contains information about H.245 configuration parameters. It is a list of configuration parameter entries. The number of entries equals to the number of H.245 stacks in a system.
OBJECT-TYPE    
  SEQUENCE OF  
    RadH245ConfigEntry

radH245ConfigEntry 1.3.6.1.4.1.164.3.1.7.6.1
It contains objects that describe the H.245 configuration parameters.
OBJECT-TYPE    
  RadH245ConfigEntry  

h245MaxJitter 1.3.6.1.4.1.164.3.1.7.6.1.1
Maximum peak to peak delivery (in miliseconds) of audio packets to the transport layer that the transmitter shall cause.
OBJECT-TYPE    
  Integer32  

h245Tunneling 1.3.6.1.4.1.164.3.1.7.6.1.2
This variable enables or disables the usage of Tunneling.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

rtpMultiplexTable 1.3.6.1.4.1.164.3.1.7.7
RTP Multiplexing table. RTP Multiplexing: In IP telephony system, the addition of packet headers, including IP, UDP and RTP headers, increases the header overhead, decreasing efficient transmission. Also, because of large numbers of short voice packets flowing into the network, Internet load increases, eventually resulting in large delay and packet loss. RTP Multiplexing is a way to send multiple RTP packets between a pair of Gateways, with a single IP frame. This will reduces the header overhead and decreases delay by enabling voice transmission with fewer packets.
OBJECT-TYPE    
  SEQUENCE OF  
    RtpMultiplexEntry

rtpMultiplexEntry 1.3.6.1.4.1.164.3.1.7.7.1
An entry in table rtpMultiplexTable.
OBJECT-TYPE    
  RtpMultiplexEntry  

rtpMultiplexedRtp 1.3.6.1.4.1.164.3.1.7.7.1.1
RTP Multiplexing is a way to send multiple RTP packets with a single IP frame. This will reduce the header overhead and decrease the delay by enabling voice transmission with fewer packets. The option of this field are: Disable - No RTP Multiplexing. multiplexType1 - medium level of compression for RTP multiplexing. multiplexType2 - high level of compression for RTP multiplexing. Using the High Compression algorithm is more efficient but will cause the loss of some RTP header information. If RTP statistics are important, the medium compression must be selected.
OBJECT-TYPE    
  INTEGER disable(2), multiplexType1(3), multiplexType2(4)  

rtpMultiplexFrameSize 1.3.6.1.4.1.164.3.1.7.7.1.2
Defines the maximum size in Bytes of the multiplexed frame. In some cases this must be limited to avoid IP fragmentation, which makes the multiplexing useless, and can also decrease the damage in case of the frame loss. At present the size is 1500.
OBJECT-TYPE    
  Integer32  

rtpMultiplexInterval 1.3.6.1.4.1.164.3.1.7.7.1.3
Defines the maximum amout of time (msec.) between multiplexed frames that are sent. Legal values: 10-90 msec.
OBJECT-TYPE    
  Integer32  

optimux 1.3.6.1.4.1.164.3.5
OBJECT IDENTIFIER    

optimuxEvents 1.3.6.1.4.1.164.3.5.0
The events for Optimux.
OBJECT-IDENTITY    

optMxConfigChange 1.3.6.1.4.1.164.3.5.0.1
The trap is sent every time there is a change in the state of one of the PS..
NOTIFICATION-TYPE    
  optIndex  
  agnLed  

optMxAgentFault 1.3.6.1.4.1.164.3.5.0.2
The trap is sent every time there is a change in the agnIndication variable. For Optimux XL family, from ver 4.1 and up, this trap should be sent upon any change in the agnNearFarConnection variable
NOTIFICATION-TYPE    
  agnIndication  
  agnLed  

optLineStatusChange 1.3.6.1.4.1.164.3.5.0.3
optLineStatusChange trap is sent when the value of an instance dsx1LineStatus changes. It can be utilized by an NMS to trigger polls. When the line status change results from a higher level line status change (i.e. ds3), then no traps for the ds1 are sent.
NOTIFICATION-TYPE    
  dsx1LineStatus  
  dsx1LineStatusLastChange  

optSlotChange 1.3.6.1.4.1.164.3.5.0.4
This trap alerts the console if there is module enrollement/de-enrollement
NOTIFICATION-TYPE    
  optMdIdx  
  optMdSltIdx  

optLoopbackStatusChange 1.3.6.1.4.1.164.3.5.0.5
This trap alerts the console if there is changes in the loopback status of some of the line.
NOTIFICATION-TYPE    
  ifIndex  
  dsx1LoopbackStatus  
  dsx3LoopbackStatus  

optXlLineStatusChange 1.3.6.1.4.1.164.3.5.0.6
optXlLineStatusChange trap is sent when the value of an instance dsx1LineStatus changes. It can be utilized by an NMS to trigger polls.
NOTIFICATION-TYPE    
  ifIndex  
  optMdModLed  
  dsx1LineStatus  
  dsx3LineStatus  

optMxConfigTable 1.3.6.1.4.1.164.3.5.1
This table contains parameters of configuration for each member of the couple of Optimux.
OBJECT-TYPE    
  SEQUENCE OF  
    OptMxConfigEntry

optMxConfigEntry 1.3.6.1.4.1.164.3.5.1.1
An entry in the Optimux Config table.
OBJECT-TYPE    
  OptMxConfigEntry  

optIndex 1.3.6.1.4.1.164.3.5.1.1.1
optIndex = 1 is for local Optimux. optIndex = 2 is for remote Optimux.
OBJECT-TYPE    
  INTEGER local(1), remote(2)  

optHWVersion 1.3.6.1.4.1.164.3.5.1.1.2
HW Version of the device.
OBJECT-TYPE    
  DisplayString  

optSWVersion 1.3.6.1.4.1.164.3.5.1.1.3
SW Version of the device.
OBJECT-TYPE    
  DisplayString  

optPSPrimary 1.3.6.1.4.1.164.3.5.1.1.4
The status of the primary Power Supply Unit.
OBJECT-TYPE    
  INTEGER unknown(1), fault(3), active(4), none(6)  

optPSSecondary 1.3.6.1.4.1.164.3.5.1.1.5
The status of the secondary Power Supply Unit.
OBJECT-TYPE    
  INTEGER unknown(1), fault(3), active(4), none(6)  

optLinkActive 1.3.6.1.4.1.164.3.5.1.1.6
This object indicates which link is active. For Optimux-4 it may be: 5, 6 or 105, 106 For FOMi-E3/T3 it may be: 51, 61 or 151, 161. For Optimux-T3 it may be: 51 or 61. For Optimux-155/1 refer to product spec.
OBJECT-TYPE    
  InterfaceIndex  


optGrpPayLoadLoop 1.3.6.1.4.1.164.3.5.1.1.8
Performs payload loop ( remote loop) to 4 E1 channels at once.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

optGrpClockSource 1.3.6.1.4.1.164.3.5.1.1.9
For Optimux XL: If dsx3TransmitClockSource = localTiming(2), then the user can configure this field as: localInternal(2) = use the internal clock of the device localExternal(3) = use the external clock connected to the port dedicated to clock. For FomiE3/T3 this object is always applicable. localExternal(3) = station clock transparent(5) = the device takes the clock info from the data. For FomiE3/T3 with HSSI electrical interface, only the following are valid: localInternal(2) and transparent(5). For Optimux-T3 the applicable values are (2), (3), (4). For Optimux-155/1 the applicable values are (2), (3), (4), (5).
OBJECT-TYPE    
  INTEGER notApplicable(1), localInternal(2), localExternal(3), loopTiming(4), transparent(5)  

optRedundancyStatus 1.3.6.1.4.1.164.3.5.1.1.10
If there are two modules 'links', then this field should be set to available(2). If there is only one module 'link', this field should be set to notAvailable(3).
OBJECT-TYPE    
  INTEGER available(2), notAvailable(3)  

optRedundancyCnf 1.3.6.1.4.1.164.3.5.1.1.11
This object is used by Optimux-XL, FomiE3/T3, Optimux-T3 and Optimux-155. For Optimux-XL: If optRedundancyStatus = notAvailable(3), then this field can be off(2) or forcedBU(6). - off(2) = forcedMain: forces the device to start immediately use of Main (Link 1), no matter what is its state and stay there - forcedBU(6) = forces the device to start immediately use of Backup (Link 2), no matter what is its state and stay there. This value is not supported by Optimux-T3. Else, user can configure this field as: auto(3) = switch back to main link when valid. manual(4) = don't switch back to main link = automatic w/o return. For FomiE3/T3 all values are applicable unconditioned. For Optimux-T3 and OP-4 New Look, values off(2), auto(3), manual(4) are applicable unconditioned. For Optimux-155/1 values off (2) = Protection Lockout, auto (3) and manual (4)
OBJECT-TYPE    
  INTEGER off(2), auto(3), manual(4), forcedBU(6)  

optFarEndType 1.3.6.1.4.1.164.3.5.1.1.12
Far-End type of product. This object is especially relevant for the local optimux. notApplicable - for devices that don't have a far-end unit.
OBJECT-TYPE    
  INTEGER unknown(1), optimux4Sa(2), optimux4Card(3), fomiE3T3Sa(4), fomiE3T3Card(5), optimuxXL16(6), optimuxXLE1(7), optimux4E1L(8), optimux4T1L(9), optimuxXLT1(10), op16E1L(11), op16E1LS(12), opXLE1(13), opXLT1(14), opXL16E1(15), op4E1(16), op4T1(17), fdsl101(18), fdsl201(19), notApplicable(255)  

optServiceChEnable 1.3.6.1.4.1.164.3.5.1.1.13
Service Channel Enable/Disable for each Optimux (local/remote).
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

optMaskChAlr 1.3.6.1.4.1.164.3.5.1.1.14
Mask Channel Alarm. This object is applicable only for Optimux cards. The value of this object is a sum of 2**n, where n is a bit assigned to a certain Channel. Bit='1' means masked. For Optimux-4: Bit0: CH1 ; Bit1: CH2 ; Bit2: CH3 ; Bit3: CH4 (Bit='1' means masked). Examples: - 15 : means that all Channels are masked. - 9 : means that Alarms of CH 1 and CH 4 are masked. For Optimux-T3: Bit0: CH1 ; Bit1: CH2 ; Bit2: CH3 ;.. Bit20: CH21 OR Bit27: CH28. For FDSL: Bit0..Bit12 : CH1..CH12; Bit13: ETH ; Bit14..Bit15: Uplink1..Uplink2.
OBJECT-TYPE    
  Integer32  

optAisEnable 1.3.6.1.4.1.164.3.5.1.1.15
AIS enable/disable. notApplicable - for devices that do not support this feature.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

optFarMng 1.3.6.1.4.1.164.3.5.1.1.16
This object is used by Optimux-XL and FomiE3/T3. Is there possibility of Far-End Management (no/yes). This object is applicable only for the Local device. notApplicable - for Remote device and devices that do not support it. no - far-end device is NOT I-Type so it doesn't have a management link to its pair-device. yes - far-end device is I-Type so it has a management link to its pair-device.
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

optClockDivision 1.3.6.1.4.1.164.3.5.1.1.17
This object is applicable only for FomiE3/T3 having an HSSI Electrical interface. It gives the possibility of Clock Division, so that Clock Rate will be less than T3/E3. notApplicable - for a device that does not support it noDivision - Clock stays as is (Internal or Transparent) half - Clock will be half the original (divided by 2) quarter - Clock will be a quarter of the original (divided by 4).
OBJECT-TYPE    
  INTEGER notApplicable(1), noDivision(2), half(3), quarter(4)  

optDteLoopEnable 1.3.6.1.4.1.164.3.5.1.1.18
DTE Loop enable/disable (for example loop command requested by router). This object is applicable only for products having HSSI interface. notApplicable - for devices that do not support this feature.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

optGrpClockSourcePrt 1.3.6.1.4.1.164.3.5.1.1.19
This object is applicable for Optimux-T3, when optGrpClockSource=localExternal. It enables the user to select the Channel or Station Clock from which the Clock is received. Valid values: 0 = notApplicable 1..28 (= CH1..CH28). 73 = Station Clock. Only T1 Channels can be used as Clock Source. For Optimux-155/1 refer to product spec for port indexing.
OBJECT-TYPE    
  Integer32  

optIncomingAlarm 1.3.6.1.4.1.164.3.5.1.1.20
State of the Incoming Alarm (On/Off), via Alarm Relay connector. This object is applicable only for Optimux-T3.
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

optDefChannelSet 1.3.6.1.4.1.164.3.5.1.1.21
Default configuration for all Optimux Channels: T1 or E1. This object is applicable only for Optimux-T3.
OBJECT-TYPE    
  INTEGER notApplicable(1), t1(2), e1(3)  

optWaitToRestore 1.3.6.1.4.1.164.3.5.1.1.22
This parameter defines the time (sec) device has to wait in the redundant state until it goes back to the default Link.
OBJECT-TYPE    
  Integer32  


optFlipUponEvent 1.3.6.1.4.1.164.3.5.1.1.24
This object allows user to define if Flip to the other port will be performed (or not), for certain possible events. Each event is represented by a bit. The value of the object is a sum of 2**n, according to the bits having '1' value. '1' - means that Flip should occur due to this event. Bit 0 (LSB) = SD (Signal Degraded).
OBJECT-TYPE    
  Integer32  

optHwMaskChAlr 1.3.6.1.4.1.164.3.5.1.1.25
Mask Channel Alarm done by the HW dip-switches. This object is applicable only for Optimux cards. The value of this object is a sum of 2**n, where n is a bit assigned to a certain Channel. For Optimux-16E1: Bit0: CH1 ; Bit1: CH2 ; Bit2: CH3 ;.. Bit15: CH16 (Bit='1' means masked). Examples: - 9 : means that Alarms of CH 1 and CH 4 are masked.
OBJECT-TYPE    
  Integer32  

optServiceChExist 1.3.6.1.4.1.164.3.5.1.1.26
Service Channel Existence indication for each Optimux (local/remote).
OBJECT-TYPE    
  INTEGER notApplicable(1), notExist(2), exist(3)  

optMxModuleTable 1.3.6.1.4.1.164.3.5.2
This table defines the type of the module enrolled in each slot.
OBJECT-TYPE    
  SEQUENCE OF  
    OptMxModuleEntry

optMxModuleEntry 1.3.6.1.4.1.164.3.5.2.1
An entry in the Optimux Module table.
OBJECT-TYPE    
  OptMxModuleEntry  

optMdIdx 1.3.6.1.4.1.164.3.5.2.1.1
optMdIdx = 1 is for local Optimux. optMdIdx = 2 is for remote Optimux.
OBJECT-TYPE    
  INTEGER local(1), remote(2)  

optMdSltIdx 1.3.6.1.4.1.164.3.5.2.1.2
For Optimux XL: Slot A = 1, Slot B = 2, Slot C = 3, Slot D = 4, Slot Link = 5, Slot BU = 6 . For FomiE3/R3: Slot of Station Clock = 3, Slot of Electrical Link = 4, Slot of Optical Main Link = 5, Slot of Optical Backup Link = 6 . For Optimux-T3: Slot of Station Clock (internal card)= 3, Slot A = 5, Slot B = 6. For Optimux-155/1: E1/T1 Slot A - 1, E1/T1 Slot B- 2, LINK-A - 5, LINK-B - 6 I/O-1 - 11, I/O-2 -12 ...I/O-6 - 16 For Optimux-155 DS3: Common Logic+E3/T3 Slot A - 1, Common Logic+E3/T3 Slot B- 2, LINK-A - 5, LINK-B - 6
OBJECT-TYPE    
  Integer32  

optMdType 1.3.6.1.4.1.164.3.5.2.1.3
Module Type and number of connectors.
OBJECT-TYPE    
  INTEGER unknown(1), noModule(2), e3linkCX34(3), e3linkOPT1(4), t3linkOPT1(5), eth1Port(6), e1FourUTP(7), e1TwoPort(8), e1TwoUB(9), t1FourPort(10), t1TwoPort(11), e1FourRJ45(12), e1FourBNC(13), e1FourMiniBNC(14), sfLink(15), stationClk(16), hssi(17), stationClkT3(18), t3linkCX45(19), hs4(20), hs2(21), hs1(22), hs1x8M(23), fastEth(24), nX64(25), nX64AndUnbalanced2E1(26), nX64AndBalanced2E1(27), nX64T1(28), nX64T1AndUnbalanced2T1(29), nX64T1AndBalanced2T1(30), ds1channels(31), op155Fiber(32), op155SingleFiber(33), op155coax(34), op63e1(35), op84t1(36), op155Ds3Cl(37), ds1channelsUnbalanced(38), fastEthNew(39)  

optMdHWVersion 1.3.6.1.4.1.164.3.5.2.1.4
HW Version of the module.
OBJECT-TYPE    
  DisplayString  

optMdModLed 1.3.6.1.4.1.164.3.5.2.1.5
The meaning of each bit depends on the module type.
OBJECT-TYPE    
  OCTET STRING  

optMdWaveLength 1.3.6.1.4.1.164.3.5.2.1.6
Wave Length of T3/E3 Optical Links in [nm] and specification if Laser or not.
OBJECT-TYPE    
  INTEGER notApplicable(1), nm850(2), nm1300(3), nm1300Laser(4), nm1550Laser(5)  

optMdTimingMode 1.3.6.1.4.1.164.3.5.2.1.7
The Module Timing mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), internal(2), external(3), lbt(4)  

optMdStatusIndication 1.3.6.1.4.1.164.3.5.2.1.8
Indication of Alarm and test status of all interfaces served by a module. For Optimux155, Each interface will be represented by 2 bits where the 1st bit (right) will specify alarm status and the 2nd bit will specify test status. e.g 00 - normal 01 - alarm active 11 - alarm active + testing 10 - testing For bits assignment per interface refer to product spec.
OBJECT-TYPE    
  Integer32  

optimuxRing 1.3.6.1.4.1.164.3.5.3
OBJECT IDENTIFIER    

optFramerPortTable 1.3.6.1.4.1.164.3.5.3.1
This table defines the connection of every ch of the framer.
OBJECT-TYPE    
  SEQUENCE OF  
    OptFramerPortEntry

optFramerPortEntry 1.3.6.1.4.1.164.3.5.3.1.1
An entry in the Optimux Framer port Connections table.
OBJECT-TYPE    
  OptFramerPortEntry  

optFramerPortIdx 1.3.6.1.4.1.164.3.5.3.1.1.1
The channel of the Framer. Valid values:1..31.
OBJECT-TYPE    
  Integer32  

optFramerPortConn 1.3.6.1.4.1.164.3.5.3.1.1.2
This parameter defines the Framer channel connection. The values will be as follows: Loop(1),Ch1(2),Ch2(3)....,Ch28(29).
OBJECT-TYPE    
  Integer32  

optFramerPortType 1.3.6.1.4.1.164.3.5.3.1.1.3
This parameter defines the Framer port (E1 or T1).
OBJECT-TYPE    
  INTEGER notApplicable(1), e1(2), t1(3)  

optFramerPortFeIpAddr 1.3.6.1.4.1.164.3.5.3.1.1.4
The IP Address of the opposite optimux in the ring,which this channel connected to.
OBJECT-TYPE    
  IpAddress  

optFramerConnChanges 1.3.6.1.4.1.164.3.5.3.2
The number of changes in Framer connection table that occured since last time there was a reset to this parameter
OBJECT-TYPE    
  Integer32  

optRing 1.3.6.1.4.1.164.3.5.3.3
Indication about Optimux special behavior: pointToPoint(2): regular operation mode (Point to Point). ring(3): this optimux is part of a ring. operations made on this device may affect other optimuxes in the Ring and vice versa. drop(4): enables connection between T3 tributary channel and physical E1/T1 port. In this mode there may be no connection between this Optimux and another Optimux While working in this mode optimux CANNOT be in PTP or Ring topology.
OBJECT-TYPE    
  INTEGER pointToPoint(2), ring(3), drop(4)  

optRingNeTable 1.3.6.1.4.1.164.3.5.3.4
This table defines which optimuxes are in the ring and the IP Address of each one.
OBJECT-TYPE    
  SEQUENCE OF  
    OptRingNeEntry

optRingNeEntry 1.3.6.1.4.1.164.3.5.3.4.1
An entry in the Optimux Ring Connections table.
OBJECT-TYPE    
  OptRingNeEntry  

optRingNeIdx 1.3.6.1.4.1.164.3.5.3.4.1.1
The index of the optimux, starting with next optimux to the current optimux. Valid values:1..28. The index is according to the order of optimux connections in the ring. Example: 1=next optimux to the current, in the ring 2=next optimux in the ring, after the one having index=1 etc.. Last index will be the current optimux, that close the ring.
OBJECT-TYPE    
  Integer32  

optRingNeIpAddr 1.3.6.1.4.1.164.3.5.3.4.1.2
The IP Address of each optimux in the ring, according to optRingNeIdx.
OBJECT-TYPE    
  IpAddress  

radGen 1.3.6.1.4.1.164.6
OBJECT IDENTIFIER    

alarmStatusTrap 1.3.6.1.4.1.164.6.1.3.0.5
The trap is sent whenever there is a transition from a no alarm state to a state with at least one active alarm.
NOTIFICATION-TYPE    
  atmInterfaceAlarmStatus  

systemTrap 1.3.6.1.4.1.164.6.1.3.0.6
This trap alerts of major problems in the device.
NOTIFICATION-TYPE    
  agnLed  
  alarmSeverity  

alarmLOS 1.3.6.1.4.1.164.6.1.3.0.7
This trap indicates Loss Of Signal.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

alarmLOF 1.3.6.1.4.1.164.6.1.3.0.8
This trap indicates Loss Of Frame.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

channelOperStatusTrap 1.3.6.1.4.1.164.6.1.3.0.9
This trap is sent upon any change in one or more channels.
NOTIFICATION-TYPE    
  ip2IfOperStatus  

alarmAIS 1.3.6.1.4.1.164.6.1.3.0.10
This trap indicates AIS.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

alarmRDI 1.3.6.1.4.1.164.6.1.3.0.11
This trap indicates RDI.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

alarmFEBE 1.3.6.1.4.1.164.6.1.3.0.12
This trap indicates FEBE.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

localConnStatusTrap 1.3.6.1.4.1.164.6.1.3.0.13
This trap is sent upon a change in Local connectivity of Bundle connection.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

remoteConnStatusTrap 1.3.6.1.4.1.164.6.1.3.0.14
This trap is sent upon a change in Remote connectivity of Bundle connection.
NOTIFICATION-TYPE    
  alarmSeverity  
  alarmState  
  ifAlias  

bundleConnectionStatusTrap 1.3.6.1.4.1.164.6.1.3.0.15
This trap is sent upon any change in the connectivity status of a Bundle (ip2IfOperStatus). The ifAlias index is the ifIndex of the bundle that its status has been changed.
NOTIFICATION-TYPE    
  ifAlias  
  ip2IfOperStatus  

radRouter 1.3.6.1.4.1.164.11
OBJECT IDENTIFIER    

rtrBridge 1.3.6.1.4.1.164.11.7
OBJECT IDENTIFIER    

webranger 1.3.6.1.4.1.164.11.7.2
OBJECT IDENTIFIER    

wrSysConfig 1.3.6.1.4.1.164.11.7.2.1
OBJECT IDENTIFIER    

wrBraodcastCtrlCmd 1.3.6.1.4.1.164.11.7.2.1.1
This parameter is a command to the webranger CPU. It enables blocking or forwarding broadcast frames, which may cause a trigger to a connection. block (1) - blocks the broadcast frames. forward (2) - forwards the broadcast frames. blockLinkPropagation (3) - blocks the broadcast frames to the links, tx to the LAN.
OBJECT-TYPE    
  INTEGER block(1), forward(2), blockLinkPropagation(3)  

wrFrSelfLearningMode 1.3.6.1.4.1.164.11.7.2.1.2
This parameter enables the webranger to learn the DLCi's configuration and maintanance protocol. off - will get the configuration by setting it. on - disables configuration and start self learning.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

wrGratuitousArp 1.3.6.1.4.1.164.11.7.2.1.3
This parameter enables/disables the Gratuitous ARP feature. When enabled, the feature means: when receiving ARP with sender's Source IP Address that already exists in the ARP table - replace MAC Address with sender's Source MAC Address.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

wrIpRouterInfo 1.3.6.1.4.1.164.11.7.2.2
OBJECT IDENTIFIER    

wrConfigIpDhcp 1.3.6.1.4.1.164.11.7.2.2.1
OBJECT IDENTIFIER    

wrDhcpAction 1.3.6.1.4.1.164.11.7.2.2.1.1
Activating (disable/enable) DHCP server operation. Since DHCP Server and DHCP Relay cannot reside in same device, DHCP Relay may be enabled (per interface), only if server action is disabled. For some devices, this object is used in order to enable/disable the DHCP Client. See device SDS.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

wrDhcpTable 1.3.6.1.4.1.164.11.7.2.2.1.2
A list of DHCP entries. The number of entries is up to DHCP current entries, according to the WEBRANger model.
OBJECT-TYPE    
  SEQUENCE OF  
    WrDhcpEntry

wrDhcpEntry 1.3.6.1.4.1.164.11.7.2.2.1.2.1
DHCP parameters per entry of the DHCP table.
OBJECT-TYPE    
  WrDhcpEntry  

wrDhcpLowIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.2.1.1
DHCP Low Ip Address.
OBJECT-TYPE    
  IpAddress  

wrDhcpHighIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.2.1.2
DHCP High Ip Address.
OBJECT-TYPE    
  IpAddress  

wrDhcpIpMaskAddress 1.3.6.1.4.1.164.11.7.2.2.1.2.1.3
IP mask Address.
OBJECT-TYPE    
  IpAddress  

wrDhcpDefaultGateway 1.3.6.1.4.1.164.11.7.2.2.1.2.1.4
Default Gateway's IP Address.
OBJECT-TYPE    
  IpAddress  

wrDhcpPrimaryDNS 1.3.6.1.4.1.164.11.7.2.2.1.2.1.5
Primary DNS.
OBJECT-TYPE    
  IpAddress  

wrDhcpSecondaryDNS 1.3.6.1.4.1.164.11.7.2.2.1.2.1.6
Secondary DNS.
OBJECT-TYPE    
  IpAddress  

wrDhcpInterface 1.3.6.1.4.1.164.11.7.2.2.1.2.1.7
The IP addresse allocation is done according to the interface type from which the DHCP request arrives.
OBJECT-TYPE    
  INTEGER all(1), lan1(2), lan2(3), anyLan(4), wan(5)  

wrDhcpRowStatus 1.3.6.1.4.1.164.11.7.2.2.1.2.1.8
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrDhcpRowStatus.id = active(1). For destroying a row, the NMS should set: wrDhcpStatus.id = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

wrDhcpIpAddressLeaseTime 1.3.6.1.4.1.164.11.7.2.2.1.2.1.9
Allocated IP Address lease time in seconds. A zero value specifies no time limitation.
OBJECT-TYPE    
  Integer32  

wrDhcpPoolName 1.3.6.1.4.1.164.11.7.2.2.1.2.1.10
DHCP pool name - string with max length of 10 characters
OBJECT-TYPE    
  SnmpAdminString SIZE(1..10)  

dhcpPoolAllocTable 1.3.6.1.4.1.164.11.7.2.2.1.3
A list of DHCP Pool Allocation entries. Each entry (row) consist of a single IP Address belonging to DHCP pool whose lowest IP address is dhcpPoolAllocLowIpAddress. This IP address may be offered for leasing, or may already be leased (in use) by Host it's MacAddress is dhcpPoolAllocMacAddress. Time left for leasing period is indicated by dhcpPoolAllocTimeLeft. All posible statuses of IP address are indicated and controlled by dhcpPoolAllocFlags
OBJECT-TYPE    
  SEQUENCE OF  
    DhcpPoolAllocEntry

dhcpPoolAllocEntry 1.3.6.1.4.1.164.11.7.2.2.1.3.1
DHCP Pool Allocation parameters per entry of the DHCP Pool Allocation table.
OBJECT-TYPE    
  DhcpPoolAllocEntry  

dhcpPoolAllocLowIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.3.1.1
Lowest IP address of this pool, value eqaul to wrDhcpLowIpAddress for the pool.
OBJECT-TYPE    
  IpAddress  

dhcpPoolAllocLeasingIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.3.1.2
Single IP Address belonging to dhcp pool whose Lowest Ip Address is dhcpPoolAllocLowIpAddress. This IP address may be offered for leasing or may be leased by Host its MacAddress is dhcpPoolAllocMacAddress. All posible statuses of IP address are indicated by dhcpPoolAllocFlags
OBJECT-TYPE    
  IpAddress  

dhcpPoolAllocMacAddress 1.3.6.1.4.1.164.11.7.2.2.1.3.1.3
MAC Address to which the IP address has been leased
OBJECT-TYPE    
  MacAddress  

dhcpPoolAllocTimeLeft 1.3.6.1.4.1.164.11.7.2.2.1.3.1.4
IP address leasing time left in seconds
OBJECT-TYPE    
  Integer32  

dhcpPoolAllocFlags 1.3.6.1.4.1.164.11.7.2.2.1.3.1.5
These flags indicates status of each IP address. User may change value to free, via dhcpPoolAllocFreeCmd
OBJECT-TYPE    
  INTEGER notApplicable(1), free(2), inUse(3), offered(4), forbidden(5)  

dhcpPoolAllocFreeCmd 1.3.6.1.4.1.164.11.7.2.2.1.3.1.6
Setting this attribute to On (3), will enforce the agent to Free this entry. The Agent will change the value of this MIB object to off(2) automatically, after performing the command. Setting this object to off(2), will do nothing
OBJECT-TYPE    
  INTEGER off(2), on(3)  

dhcpRelayTable 1.3.6.1.4.1.164.11.7.2.2.1.4
A list of DHCP relay entries.
OBJECT-TYPE    
  SEQUENCE OF  
    DhcpRelayEntry

dhcpRelayEntry 1.3.6.1.4.1.164.11.7.2.2.1.4.1
DHCP Relay parameters per entry of the DHCP relay table.
OBJECT-TYPE    
  DhcpRelayEntry  

dhcpRelayAction 1.3.6.1.4.1.164.11.7.2.2.1.4.1.1
Setting this attribute to enable (3), will enable DHCP Relay action for this interface (Only if DHCP Server is disabled for device - wrDhcpAction=disable). dhcpRelayServerIpAddressaddress should not be 0.0.0.0 when enable is set
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

dhcpRelayServerIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.4.1.2
DHCP Server IP Address.
OBJECT-TYPE    
  IpAddress  

dhcpRelayMaxHop 1.3.6.1.4.1.164.11.7.2.2.1.4.1.3
Maximum number of hops till DHCP Server. upper limit is 16 hops
OBJECT-TYPE    
  Integer32  

wrDhcpPort 1.3.6.1.4.1.164.11.7.2.2.1.5
This parameter defines the port that DHCP flow will be actiavted.
OBJECT-TYPE    
  INTEGER notApplicable(1), all(2), outOfBand(3), lan1(4), lan2(5)  

dhcpClientTable 1.3.6.1.4.1.164.11.7.2.2.1.6
A list of DHCP client entries.
OBJECT-TYPE    
  SEQUENCE OF  
    DhcpClientEntry

dhcpClientEntry 1.3.6.1.4.1.164.11.7.2.2.1.6.1
DHCP Client parameters per entry of the DHCP Client table.
OBJECT-TYPE    
  DhcpClientEntry  

dhcpClientAction 1.3.6.1.4.1.164.11.7.2.2.1.6.1.1
This parameter default value is enable(3). Setting this attribute to disable (2), will disable DHCP Client action for this interface. This parameter can be changed to disable (2) only (it cannot be changed from disable to enable).
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

dhcpClientServerIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.6.1.2
DHCP Server IP Address.
OBJECT-TYPE    
  IpAddress  

dhcpClientLeaseExpirationTime 1.3.6.1.4.1.164.11.7.2.2.1.6.1.3
This parameter holds the time (in minutes) left until lease expiration.
OBJECT-TYPE    
  Integer32  

dhcpClientStatus 1.3.6.1.4.1.164.11.7.2.2.1.6.1.4
This parametr displays the DHCP status.
OBJECT-TYPE    
  DisplayString  

dhcpIfClientTable 1.3.6.1.4.1.164.11.7.2.2.1.7
DHCP client entries for each Interface.
OBJECT-TYPE    
  SEQUENCE OF  
    DhcpIfClientEntry

dhcpIfClientEntry 1.3.6.1.4.1.164.11.7.2.2.1.7.1
DHCP Clients per entry of the DHCP Interface Client table.
OBJECT-TYPE    
  DhcpIfClientEntry  

dhcpIfClientIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.7.1.2
DHCP Client IP Address.
OBJECT-TYPE    
  IpAddress  

dhcpIfClientRowStatus 1.3.6.1.4.1.164.11.7.2.2.1.7.1.3
The row status used for creating, modifying, and deleting instances of the columnar objects in the dhcpIfClientTable. For Vmux Devices, it will be possible only to Delete instances. The addition of Clients will be done automatically by the Server according to Network messages that are sent by the Clients; not via SNMP. In order to Delete a Client, this MIB object should be set to: destroy (6).
OBJECT-TYPE    
  RowStatus  

dhcpServerAction 1.3.6.1.4.1.164.11.7.2.2.1.8
This variable enables the operator to perform one of the specified actions on the Server. deleteAllClients (3) is an option that is used for a device functioning as a server. It will remove all the clients from all the interfaces of the device. When the operation is complete, the agent will return a noOp (2) value.
OBJECT-TYPE    
  INTEGER noOp(2), deleteAllClients(3)  

wrConfigIpDNS 1.3.6.1.4.1.164.11.7.2.2.2
OBJECT IDENTIFIER    

wrDNSRelayAction 1.3.6.1.4.1.164.11.7.2.2.2.1
When Enabled, device will act as a DNS Relay: whenever the device receives a DNS request from its host, it will forward it to the DNS server as if the request was initiated by the device itself. The reply from the DNS server is forwarded by the device to the host as if the device was answering the request.
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

wrConfigIpxRouterInfo 1.3.6.1.4.1.164.11.7.2.3
OBJECT IDENTIFIER    

wrAutoLearnLanIpxNets 1.3.6.1.4.1.164.11.7.2.3.1
Activating (disable/enable) the auto-learn operation.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

wrLanIpxNetTable 1.3.6.1.4.1.164.11.7.2.3.2
Lan IPX nets Table.
OBJECT-TYPE    
  SEQUENCE OF  
    WrLanIpxNetEntry

wrLanIpxNetEntry 1.3.6.1.4.1.164.11.7.2.3.2.1
IPX Nets per frame type & LAN port. The table entries will be created by the agent
OBJECT-TYPE    
  WrLanIpxNetEntry  

wrLanifIndex 1.3.6.1.4.1.164.11.7.2.3.2.1.1
LAN port ifIndex.
OBJECT-TYPE    
  Integer32  

wrLanIpxFrameType 1.3.6.1.4.1.164.11.7.2.3.2.1.2
Frame Type
OBJECT-TYPE    
  INTEGER t8023(1), ethernet(2), t8022(3), snap(4)  

wrIpxNetAddress 1.3.6.1.4.1.164.11.7.2.3.2.1.3
Net address per Frame Type & LAN port.
OBJECT-TYPE    
  IpAddress  

wrDialInIpxNet 1.3.6.1.4.1.164.11.7.2.3.3
Net address through a link.
OBJECT-TYPE    
  IpAddress  

ripSapIfConfTable 1.3.6.1.4.1.164.11.7.2.3.4
A list of Interfaces which require separate configuration in RIP/SAP.
OBJECT-TYPE    
  SEQUENCE OF  
    RipSapIfConfEntry

ripSapIfConfEntry 1.3.6.1.4.1.164.11.7.2.3.4.1
A Single Routing Domain in a single Subnet.
OBJECT-TYPE    
  RipSapIfConfEntry  

ripSapIfConfIfIndex 1.3.6.1.4.1.164.11.7.2.3.4.1.1
The interface ifIndex.
OBJECT-TYPE    
  Integer32  

ripSapIfConfMode 1.3.6.1.4.1.164.11.7.2.3.4.1.2
The ifIndex RIP/SAP mode.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ripSapIfConfStatus 1.3.6.1.4.1.164.11.7.2.3.4.1.3
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set ripSapIfConfStatus.id1 = active(1). For destroying a row, the NMS should set: ripSapIfConfStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

wrInterface 1.3.6.1.4.1.164.11.7.2.4
OBJECT IDENTIFIER    

wrIpAddressTable 1.3.6.1.4.1.164.11.7.2.4.1
Link IP addresses Table.
OBJECT-TYPE    
  SEQUENCE OF  
    WrIpAddressEntry

wrIpAddressEntry 1.3.6.1.4.1.164.11.7.2.4.1.1
Ip Address per Link
OBJECT-TYPE    
  WrIpAddressEntry  

wrIpIfIndex 1.3.6.1.4.1.164.11.7.2.4.1.1.1
Port interface index.
OBJECT-TYPE    
  Integer32  

wrIpAddress 1.3.6.1.4.1.164.11.7.2.4.1.1.2
Link IP Address.
OBJECT-TYPE    
  IpAddress  

wrIpMask 1.3.6.1.4.1.164.11.7.2.4.1.1.3
Link IP mask Address.
OBJECT-TYPE    
  IpAddress  

wrIpRowStatus 1.3.6.1.4.1.164.11.7.2.4.1.1.4
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrIpRowStatus.id1 = active(1). For destroying a row, the NMS should set: wrIpRowStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

wrSpoofingTable 1.3.6.1.4.1.164.11.7.2.4.2
Spoofing Table.
OBJECT-TYPE    
  SEQUENCE OF  
    WrSpoofingEntry

wrSpoofingEntry 1.3.6.1.4.1.164.11.7.2.4.2.1
Spoofing per Link
OBJECT-TYPE    
  WrSpoofingEntry  

wrSpoofingIfIndex 1.3.6.1.4.1.164.11.7.2.4.2.1.1
Port interface index.
OBJECT-TYPE    
  Integer32  

wrSpoofingAction 1.3.6.1.4.1.164.11.7.2.4.2.1.2
Spoofing action is applied by bit code: enable : bit 0 set (disable: bit 0 is 0) keepAlive : bit 1 ... : bit 2 and so on. For the above example, to set spoofing to keepAlive action, the object's value will be 3 = [ 2**0 + 2**1 ] Only the Remote WEBRANger will accept this object ! -------
OBJECT-TYPE    
  Integer32  

wrSpoofingAgingStation 1.3.6.1.4.1.164.11.7.2.4.2.1.3
Aging time of stations list, in min. The agent 'translates' the time entered in minutes, to 10 min. resolution, as follows: 1..10 min - 10 min 11..20 min - 20 min and so on... 0 is not a valid value. Only the Remote WEBRANger will accept this object ! ----------------
OBJECT-TYPE    
  Integer32  

wrSpoofingRowStatus 1.3.6.1.4.1.164.11.7.2.4.2.1.4
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrSpoofingRowStatus.id1 = active(1). For destroying a row, the NMS should set: wrSpoofingRowStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
OBJECT-TYPE    
  RowStatus  

wrLanIfTable 1.3.6.1.4.1.164.11.7.2.4.3
Link IP addresses Table.
OBJECT-TYPE    
  SEQUENCE OF  
    WrLanIfEntry

wrLanIfEntry 1.3.6.1.4.1.164.11.7.2.4.3.1
Ip Address per Link
OBJECT-TYPE    
  WrLanIfEntry  

wrLanIfIndex 1.3.6.1.4.1.164.11.7.2.4.3.1.1
Port interface index.
OBJECT-TYPE    
  Integer32  

wrLanBridgeRouterMode 1.3.6.1.4.1.164.11.7.2.4.3.1.2
This parameter indicates whether the link is Bridge or Router and specifies the Router's type.
OBJECT-TYPE    
  INTEGER unknown(1), bridge(2), ipRouter(3), ipxRouter(4), ipAndIpxRouter(5), bRouter(6), ipBrouter(7), ipxBrouter(8), ipAndIpxBrouter(9), bridgeAndStp(10)  

wrLanIfState 1.3.6.1.4.1.164.11.7.2.4.3.1.3
The LAN is disabled or enabled. For LAN 2 it can be also 'redundancy'.
OBJECT-TYPE    
  INTEGER disable(2), enable(3), redundancy(4)  

wrLanIfRdnTimeout 1.3.6.1.4.1.164.11.7.2.4.3.1.4
LAN Redundancy Timeout in seconds. Applicable when wrLanIfState=redundancy.
OBJECT-TYPE    
  Integer32  

wrSyncCnfgTable 1.3.6.1.4.1.164.11.7.2.4.4
Configuration table for Async interface.
OBJECT-TYPE    
  SEQUENCE OF  
    WrSyncCnfgEntry

wrSyncCnfgEntry 1.3.6.1.4.1.164.11.7.2.4.4.1
Configuration table
OBJECT-TYPE    
  WrSyncCnfgEntry  

wrSyncIfIndex 1.3.6.1.4.1.164.11.7.2.4.4.1.1
Sync interface index.
OBJECT-TYPE    
  Integer32  

wrSyncClkMode 1.3.6.1.4.1.164.11.7.2.4.4.1.2
Clock Mode.
OBJECT-TYPE    
  INTEGER notApplicable(1), manual(2), program(3)  

wrSyncClkRate 1.3.6.1.4.1.164.11.7.2.4.4.1.3
Clock Rate in. Rate can be changed if Clock Mode is Program only.
OBJECT-TYPE    
  INTEGER notApplicable(1), r16(2), r32(3), r48(4), r64(5), r96(6), r128(7), r256(8), r768(9)  

wrFrCnfgTable 1.3.6.1.4.1.164.11.7.2.4.5
Configuration table for Fr parameters that do not exist in RFC2115.
OBJECT-TYPE    
  SEQUENCE OF  
    WrFrCnfgEntry

wrFrCnfgEntry 1.3.6.1.4.1.164.11.7.2.4.5.1
Configuration entry for Fr parameters that do not exist in RFC2115.
OBJECT-TYPE    
  WrFrCnfgEntry  

wrFrDlciLearningMode 1.3.6.1.4.1.164.11.7.2.4.5.1.1
This parameter enables the webranger to learn the DLCi's configuration and maintanance protocol for the current interface. off - the WR will read the user's configuration for this interface. on - the WR will begin self learning of the current interface's maintanance protocol and DLCIs.
OBJECT-TYPE    
  INTEGER off(2), on(3)  

wrFrCllmMessages 1.3.6.1.4.1.164.11.7.2.4.5.1.2
This parameter enables/disables the Webranger to Tx/Rx CLLM (Consolidated Link Layer Management) messages via DLCI 1023. The CLLM messages are link layer control messages. They can be used for example in cases of congestion. The CLLM message contains a code for cause of congestion and list of all DLCIs that should act to reduce data transmission.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ipRouter 1.3.6.1.4.1.164.11.7.3
OBJECT IDENTIFIER    

rtrIfIpTable 1.3.6.1.4.1.164.11.7.3.1
Router interfaces table.
OBJECT-TYPE    
  SEQUENCE OF  
    RtrIfIpEntry

rtrIfIpEntry 1.3.6.1.4.1.164.11.7.3.1.1
An entry in table rtrIfIpTable.
OBJECT-TYPE    
  RtrIfIpEntry  

rtrIfIp 1.3.6.1.4.1.164.11.7.3.1.1.1
IP Address.
OBJECT-TYPE    
  IpAddress  

rtrIfRowStatus 1.3.6.1.4.1.164.11.7.3.1.1.2
.
OBJECT-TYPE    
  RowStatus  

rtrIfIpMask 1.3.6.1.4.1.164.11.7.3.1.1.3
IP mask Address.
OBJECT-TYPE    
  IpAddress  

rtrIfIndex 1.3.6.1.4.1.164.11.7.3.1.1.4
The ifIndex connection, on which the IP is determined.
OBJECT-TYPE    
  Integer32  

rtrIfMng 1.3.6.1.4.1.164.11.7.3.1.1.5
An IP interface might be determined as a management connection (under the product limitations).
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

rtrIfVlanId 1.3.6.1.4.1.164.11.7.3.1.1.6
The VLAN ID assigned to Tagged frames transmitted from this port. The value inserted should be a defined VLAN.
OBJECT-TYPE    
  VlanIndex  

brtrIfTable 1.3.6.1.4.1.164.11.7.3.2
LAN interface table.
OBJECT-TYPE    
  SEQUENCE OF  
    BrtrIfEntry

brtrIfEntry 1.3.6.1.4.1.164.11.7.3.2.1
The entries of this table will be created by agent.
OBJECT-TYPE    
  BrtrIfEntry  

brtrIfIndex 1.3.6.1.4.1.164.11.7.3.2.1.1
The index of the interface (LAN or ATM).
OBJECT-TYPE    
  Integer32  

brtrIfMode 1.3.6.1.4.1.164.11.7.3.2.1.2
Connection Mode.
OBJECT-TYPE    
  INTEGER bridge(1), router(2), brouter(3), off(4)  

brtrIfMaxFrameSize 1.3.6.1.4.1.164.11.7.3.2.1.3
Frame Max Size.
OBJECT-TYPE    
  Integer32  

rtrArpAgingTime 1.3.6.1.4.1.164.11.7.3.3
ARP Aging Time. Applicable for a Router Mode and for a Brouter Mode.
OBJECT-TYPE    
  Integer32  

brtrLanIfTable 1.3.6.1.4.1.164.11.7.3.4
LAN interface table.
OBJECT-TYPE    
  SEQUENCE OF  
    BrtrLanIfEntry

brtrLanIfEntry 1.3.6.1.4.1.164.11.7.3.4.1
The entries of this table will be created by agent .
OBJECT-TYPE    
  BrtrLanIfEntry  

brtrLanIfIndex 1.3.6.1.4.1.164.11.7.3.4.1.1
The index of the LAN entity (physical interface).
OBJECT-TYPE    
  Integer32  

brtrLanIpAddress 1.3.6.1.4.1.164.11.7.3.4.1.2
Host IP address. Applicable for bridge mode connection only.
OBJECT-TYPE    
  IpAddress  

brtrLanIpMask 1.3.6.1.4.1.164.11.7.3.4.1.3
Host IP Mask. Applicable for bridge mode connection only.
OBJECT-TYPE    
  IpAddress  

brtrLanMaxRateEnable 1.3.6.1.4.1.164.11.7.3.4.1.4
This parameter determines the HW ability of the LAN card according to HW.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

brtrLanMaxRate 1.3.6.1.4.1.164.11.7.3.4.1.5
Max Rate.
OBJECT-TYPE    
  Integer32  

brtrLanMng 1.3.6.1.4.1.164.11.7.3.4.1.6
An IP interface might be determined as a management connection (under the product limitations).
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

brtrLanDefaultRouter 1.3.6.1.4.1.164.11.7.3.4.1.7
Default Router's (Gateway's) IP Address. For each LAN interface there may be a different Default Router.
OBJECT-TYPE    
  IpAddress  

rtrIsdnIfTable 1.3.6.1.4.1.164.11.7.3.5
This table contains ISDN parameters that do not appear in the standard MIBs.
OBJECT-TYPE    
  SEQUENCE OF  
    RtrIsdnIfEntry

rtrIsdnIfEntry 1.3.6.1.4.1.164.11.7.3.5.1
Entries for ISDN parameters that do not appear in the standard MIBs.
OBJECT-TYPE    
  RtrIsdnIfEntry  

rtrIsdnIfMinNumBchans 1.3.6.1.4.1.164.11.7.3.5.1.1
Minimum number of B channels that the ISDN Dialer of the router will use for Dialing out. This parameter will be used for the BOD (Bandwidth On Demand) feature. Dial up on B channels is according to the need of bandwidth for router data transfer. Voice calls have a higher priority than router data. In case of few time slots the voice calls will cause disconnection of data channels up to the limit of minimum number of B channels.
OBJECT-TYPE    
  Integer32  

rtrIsdnIfMaxNumBchans 1.3.6.1.4.1.164.11.7.3.5.1.2
Maximum number of B channels that the ISDN Dialer of the router will use for Dialing out. This parameter will be used for the BOD (Bandwidth On Demand) feature. Dial up on B channels is according to the need of bandwidth for router data transfer. Voice calls have a higher priority than router data. No more than MAX B channels will be used by the ISDN dialer.
OBJECT-TYPE    
  Integer32  

rtrLcrTable 1.3.6.1.4.1.164.11.7.3.6
Least Cost Routing Table. The user will be able to set a prefix for an outgoing number that arrives with a predefined prefix in order to redirect the number for the LCR process to be achieved.
OBJECT-TYPE    
  SEQUENCE OF  
    RtrLcrEntry

rtrLcrEntry 1.3.6.1.4.1.164.11.7.3.6.1
Least Cost Routing Entry.
OBJECT-TYPE    
  RtrLcrEntry  

rtrLcrOutIfIndex 1.3.6.1.4.1.164.11.7.3.6.1.1
The outgoing interface Number of the current route. The incoming interface number is the value of ifIndex.
OBJECT-TYPE    
  InterfaceIndex  

rtrLcrRowStatus 1.3.6.1.4.1.164.11.7.3.6.1.2
Row Status for adding/destroying rows.
OBJECT-TYPE    
  RowStatus  

rtrLcrInPrefix 1.3.6.1.4.1.164.11.7.3.6.1.3
This prefix is part of the called number existing in the incoming packet.
OBJECT-TYPE    
  DisplayString  

rtrLcrOutPrefix 1.3.6.1.4.1.164.11.7.3.6.1.4
This prefix will be inserted into the outgoing packet.
OBJECT-TYPE    
  DisplayString  

multicastGen 1.3.6.1.4.1.164.11.8
OBJECT IDENTIFIER    

multicastMode 1.3.6.1.4.1.164.11.8.1
According to this mode the packets will be forwarded. If disable (2) is selected, there will be no multicast.
OBJECT-TYPE    
  INTEGER disable(2), wanToLan(3), wanToLanIgmp(4), lanToWan(5), bidirectional(6), transparent(7)  

Defined Objects

OptMxConfigEntry  
SEQUENCE    
  INTEGER as optIndex  
  DisplayString as optHWVersion  
  DisplayString as optSWVersion  
  INTEGER as optPSPrimary  
  INTEGER as optPSSecondary  
  InterfaceIndex as optLinkActive  
  INTEGER as optSelectLink  
  INTEGER as optGrpPayLoadLoop  
  INTEGER as optGrpClockSource  
  INTEGER as optRedundancyStatus  
  INTEGER as optRedundancyCnf  
  INTEGER as optFarEndType  
  INTEGER as optServiceChEnable  
  Integer32 as optMaskChAlr  
  INTEGER as optAisEnable  
  INTEGER as optFarMng  
  INTEGER as optClockDivision  
  INTEGER as optDteLoopEnable  
  Integer32 as optGrpClockSourcePrt  
  INTEGER as optIncomingAlarm  
  INTEGER as optDefChannelSet  
  Integer32 as optWaitToRestore  
  INTEGER as optEnforcedLink  
  Integer32 as optFlipUponEvent  
  Integer32 as optHwMaskChAlr  
  INTEGER as optServiceChExist  

OptMxModuleEntry  
SEQUENCE    
  INTEGER as optMdIdx  
  Integer32 as optMdSltIdx  
  INTEGER as optMdType  
  DisplayString as optMdHWVersion  
  OCTET STRING as optMdModLed  
  INTEGER as optMdWaveLength  
  INTEGER as optMdTimingMode  
  Integer32 as optMdStatusIndication  

OptFramerPortEntry  
SEQUENCE    
  Integer32 as optFramerPortIdx  
  Integer32 as optFramerPortConn  
  INTEGER as optFramerPortType  
  IpAddress as optFramerPortFeIpAddr  

OptRingNeEntry  
SEQUENCE    
  Integer32 as optRingNeIdx  
  IpAddress as optRingNeIpAddr  

WrDhcpEntry  
SEQUENCE    
  IpAddress as wrDhcpLowIpAddress  
  IpAddress as wrDhcpHighIpAddress  
  IpAddress as wrDhcpIpMaskAddress  
  IpAddress as wrDhcpDefaultGateway  
  IpAddress as wrDhcpPrimaryDNS  
  IpAddress as wrDhcpSecondaryDNS  
  INTEGER as wrDhcpInterface  
  RowStatus as wrDhcpRowStatus  
  Integer32 as wrDhcpIpAddressLeaseTime  
  SnmpAdminString as wrDhcpPoolName  

DhcpPoolAllocEntry  
SEQUENCE    
  IpAddress as dhcpPoolAllocLowIpAddress  
  IpAddress as dhcpPoolAllocLeasingIpAddress  
  MacAddress as dhcpPoolAllocMacAddress  
  Integer32 as dhcpPoolAllocTimeLeft  
  INTEGER as dhcpPoolAllocFlags  
  INTEGER as dhcpPoolAllocFreeCmd  

DhcpRelayEntry  
SEQUENCE    
  INTEGER as dhcpRelayAction  
  IpAddress as dhcpRelayServerIpAddress  
  Integer32 as dhcpRelayMaxHop  

DhcpClientEntry  
SEQUENCE    
  INTEGER as dhcpClientAction  
  IpAddress as dhcpClientServerIpAddress  
  Integer32 as dhcpClientLeaseExpirationTime  
  DisplayString as dhcpClientStatus  

DhcpIfClientEntry  
SEQUENCE    
  IpAddress as dhcpIfClientIpAddress  
  RowStatus as dhcpIfClientRowStatus  

WrLanIpxNetEntry  
SEQUENCE    
  Integer32 as wrLanifIndex  
  INTEGER as wrLanIpxFrameType  
  IpAddress as wrIpxNetAddress  

RipSapIfConfEntry  
SEQUENCE    
  Integer32 as ripSapIfConfIfIndex  
  INTEGER as ripSapIfConfMode  
  RowStatus as ripSapIfConfStatus  

WrIpAddressEntry  
SEQUENCE    
  Integer32 as wrIpIfIndex  
  IpAddress as wrIpAddress  
  IpAddress as wrIpMask  
  RowStatus as wrIpRowStatus  

WrSpoofingEntry  
SEQUENCE    
  Integer32 as wrSpoofingIfIndex  
  Integer32 as wrSpoofingAction  
  Integer32 as wrSpoofingAgingStation  
  RowStatus as wrSpoofingRowStatus  

WrLanIfEntry  
SEQUENCE    
  Integer32 as wrLanIfIndex  
  INTEGER as wrLanBridgeRouterMode  
  INTEGER as wrLanIfState  
  Integer32 as wrLanIfRdnTimeout  

WrSyncCnfgEntry  
SEQUENCE    
  Integer32 as wrSyncIfIndex  
  INTEGER as wrSyncClkMode  
  INTEGER as wrSyncClkRate  

WrFrCnfgEntry  
SEQUENCE    
  INTEGER as wrFrDlciLearningMode  
  INTEGER as wrFrCllmMessages  

RtrIfIpEntry  
SEQUENCE    
  IpAddress as rtrIfIp  
  RowStatus as rtrIfRowStatus  
  IpAddress as rtrIfIpMask  
  Integer32 as rtrIfIndex  
  INTEGER as rtrIfMng  
  VlanIndex as rtrIfVlanId  

BrtrIfEntry  
SEQUENCE    
  Integer32 as brtrIfIndex  
  INTEGER as brtrIfMode  
  Integer32 as brtrIfMaxFrameSize  

BrtrLanIfEntry  
SEQUENCE    
  Integer32 as brtrLanIfIndex  
  IpAddress as brtrLanIpAddress  
  IpAddress as brtrLanIpMask  
  INTEGER as brtrLanMaxRateEnable  
  Integer32 as brtrLanMaxRate  
  INTEGER as brtrLanMng  
  IpAddress as brtrLanDefaultRouter  

RtrIsdnIfEntry  
SEQUENCE    
  Integer32 as rtrIsdnIfMinNumBchans  
  Integer32 as rtrIsdnIfMaxNumBchans  

RtrLcrEntry  
SEQUENCE    
  InterfaceIndex as rtrLcrOutIfIndex  
  RowStatus as rtrLcrRowStatus  
  DisplayString as rtrLcrInPrefix  
  DisplayString as rtrLcrOutPrefix  

NplPulseEntry  
SEQUENCE    
  INTEGER as nplPulseType  
  INTEGER as nplPulseValid  
  Integer32 as nplPulseDurationType  
  Integer32 as nplPulseOnTime  
  Integer32 as nplPulseOffTime  

V51VarEntry  
SEQUENCE    
  Integer32 as v51VarCnfgIdx  
  INTEGER as v51VarSltIdx  
  Integer32 as v51VarPrtIdx  
  Integer32 as v51VarIdx  
  INTEGER as v51VarPstnCch  
  INTEGER as v51VarIsdnSTypeCch  
  DisplayString as v51VarDescription  
  INTEGER as v51VarStatus  
  INTEGER as v51VarRowStatus  

V51VarCfgEntry  
SEQUENCE    
  Integer32 as v51VarCfgIndex  
  INTEGER as v51VarCfgSltIdx  
  Integer32 as v51VarCfgPrtIdx  
  Integer32 as v51VarCfgIdx  
  Integer32 as v51VarCfgTsIdx  
  INTEGER as v51VarCfgTsType  
  Integer32 as v51VarCfgPrtId  
  Integer32 as v51VarCfgEfL3Addr  
  Integer32 as v51VarCfgFTypeCch  
  Integer32 as v51VarCfgPTypeCch  
  INTEGER as v51VarCfgConSlt  
  Integer32 as v51VarCfgConPrt  
  INTEGER as v51VarCfgIoState  
  INTEGER as v51VarCfgBlock  
  INTEGER as v51VarCfgExtDch  
  INTEGER as v51VarCfgExtDchSlot  
  Integer32 as v51VarCfgExtDchPort  
  Integer32 as v51VarCfgExtDchTs  
  INTEGER as v51VarCfgExtDchCmpr  
  INTEGER as v51VarCfgExtDchRate  
  Integer32 as v51VarCfgExtDchStartBit  
  Integer32 as v51VarCfgSTypeCch  
  INTEGER as v51VarCfgStatus  
  Integer32 as v51VarCfgV52MasterTsa  

V5VarCchEntry  
SEQUENCE    
  Integer32 as v5VarCchCfgIndex  
  Integer32 as v5VarCchVarIdx  
  Integer32 as v5VarCchIdx  
  INTEGER as v5VarCchType  
  Integer32 as v5VarCchPhyLinkNo  
  Integer32 as v5VarCchLogicalId  
  Integer32 as v5VarCchTs  
  INTEGER as v5VarCchPstn  
  Integer32 as v5VarCchIsdnTypes  

V5VarStatEntry  
SEQUENCE    
  Integer32 as v5VarStatIdx  
  Integer32 as v5VarStatPrtId  
  INTEGER as v5VarStatPortType  
  Integer32 as v5VarStatEfL3Addr  
  INTEGER as v5VarStatPortState  
  Integer32 as v5VarStatMasterTsa  
  INTEGER as v5VarStatCallState  

V51MlEntry  
SEQUENCE    
  INTEGER as v51MlSltIdx  
  Integer32 as v51MlPrtIdx  
  Integer32 as v51MlCurrActiveVar  
  Integer32 as v51MlLeActiveReqVar  
  INTEGER as v51MlProtocolState  
  Integer32 as v51MlUserActiveVarReq  
  Integer32 as v51MlDeleteVarReq  
  Integer32 as v51MlSaveVariant  
  Integer32 as v51MlReadVariant  
  Integer32 as v51MlDeactivateVar  

V51MlCnfgEntry  
SEQUENCE    
  Integer32 as v51MlCnfgIdx  
  INTEGER as v51MlCnfgSltIdx  
  Integer32 as v51MlCnfgPrtIdx  
  Integer32 as v51MlCnfgIfId  
  INTEGER as v51MlCnfgStartupMode  
  INTEGER as v51MlCnfgReprovision  
  INTEGER as v51MlCnfgUnblockIoPorts  
  INTEGER as v51MlCnfgRestartComplete  
  INTEGER as v51MlCnfgV52Application  

V51IoCnfgEntry  
SEQUENCE    
  Integer32 as v51IoCnfgIdx  
  INTEGER as v51IoCnfgSltIdx  
  Integer32 as v51IoCnfgPrtIdx  
  INTEGER as v51IoCnfgSType  
  INTEGER as v51IoCnfgFType  
  INTEGER as v51IoCnfgPType  

GkGenEntry  
SEQUENCE    
  INTEGER as gkGenCallMode  
  Integer32 as gkGenMaxConnections  
  Integer32 as gkGenDefaultDistance  
  Integer32 as gkGenOutOfZoneDist  
  INTEGER as gkGenCallAcceptPolicy  
  Integer32 as gkGenIrqInterval  
  Integer32 as gkGenQ931Port  
  Integer32 as gkGenRasPort  
  INTEGER as gkGenRegPolicy  
  OCTET STRING as gkGenZoneId  

GkEndpEntry  
SEQUENCE    
  MmAliasTag as gkEndpAliasTag  
  MmAliasAddress as gkEndpAlias  
  RowStatus as gkEndpRowStatus  
  MmTAddressTag as gkEndpAddressTag  
  TAddress as gkEndpAddress  
  MmEndpointID as gkEndpID  
  MmH323EndpointType as gkEndpType  
  Integer32 as gkEndpQ931Port  
  Integer32 as gkEndpDistance  
  INTEGER as gkEndpRegMode  
  INTEGER as gkEndpSetOnline  
  INTEGER as gkEndpStatus  

GkNeighbEntry  
SEQUENCE    
  MmTAddressTag as gkNeighbAddressTag  
  TAddress as gkNeighbAddress  
  RowStatus as gkNeighbRowStatus  
  MmAliasAddress as gkNeighbLeadingAlias  
  Integer32 as gkNeighbDistance  
  MmGatekeeperID as gkNeighbDescription  

GwGenEntry  
SEQUENCE    
  MmEndpointID as gwGenGwId  
  Integer32 as gwGenQ931Port  
  Integer32 as gwGenRasPort  
  INTEGER as gwGenMode  
  Integer32 as gwGenVoipExtension  
  TAddress as gwGenRemGwAddress  
  Integer32 as gwGenMaxConnections  
  OCTET STRING as gwGenTOS  
  TAddress as gwGenBackupGkAddr  
  Integer32 as gwGenTimeToRegister  

RadH245ConfigEntry  
SEQUENCE    
  Integer32 as h245MaxJitter  
  INTEGER as h245Tunneling  

RtpMultiplexEntry  
SEQUENCE    
  INTEGER as rtpMultiplexedRtp  
  Integer32 as rtpMultiplexFrameSize  
  Integer32 as rtpMultiplexInterval  

Ip2IfEntry  
SEQUENCE    
  Integer32 as ip2IfChannelIndex  
  RowStatus as ip2IfRowStatus  
  INTEGER as ip2IfOperStatus  
  INTEGER as ip2IfAdminStatus  
  IpAddress as ip2IfDestAddr  
  IpAddress as ip2IfNextHop  
  Integer32 as ip2IfDestPort  
  MacAddress as ip2IfMacAddr  
  Integer32 as ip2IfJitterBuffer  
  Integer32 as ip2IfTos  
  Integer32 as ip2IfTDMBytesInFrame  
  INTEGER as ip2IfVlanSupport  
  Integer32 as ip2IfVlanIdentifier  
  Integer32 as ip2IfVlanFramePriority  
  INTEGER as ip2IfExitPort  
  OCTET STRING as ip2IfVoiceOos  
  OCTET STRING as ip2IfDataOos  
  Integer32 as ip2IfBundleUsage  
  OCTET STRING as ip2IfOAM  
  INTEGER as ip2IfTDMoIpMode  
  Integer32 as ip2IfTimeElapsed  
  Integer32 as ip2IfValidIntervals  
  INTEGER as ip2IfFarEndType  
  INTEGER as ip2IfRdnState  
  IpAddress as ip2IfSourceAddr  
  Integer32 as ip2IfBandWidth  
  Integer32 as ip2IfMeasuredSilence  
  INTEGER as ip2IfPayloadType  
  INTEGER as ip2IfProtocolVersion  
  IpAddress as ip2IfTdmBackUpNextHop  
  INTEGER as ip2IfOosTxEnable  
  Integer32 as ip2IfConnCheckPktFrequency  
  Integer32 as ip2IfConnPktTimeOutCycles  
  INTEGER as ip2IfMfRelay  
  Integer32 as ip2IfTxGain  
  INTEGER as ip2IfSuperTandem  
  Integer32 as ip2IfSrcPort  
  INTEGER as ip2IfModemCalls  
  Integer32 as ip2IfMinPulseWidth  
  Integer32 as ip2IfMinPowerLevel  
  INTEGER as ip2IfEchoCanceler  
  INTEGER as ip2IfCodingLaw  
  INTEGER as ip2IfCustomToneDetect  
  Integer32 as ip2IfCallerIdDelay  
  INTEGER as ip2IfConnectivityMode  
  INTEGER as ip2IfMfcSpoofing  
  Integer32 as ip2IfToneAckInterval  
  INTEGER as ip2IfNoiseLevelForVAD  

Ip2IfStatEntry  
SEQUENCE    
  Integer32 as ip2IfStatChIndex  
  Integer32 as ip2IfStatSeqErrors  
  Integer32 as ip2IfStatBufUnderflows  
  Integer32 as ip2IfStatBufOverflows  
  Counter32 as ip2IfStatTxOnTimeInterval  
  Counter32 as ip2IfStatTxOnMaxSize  
  Counter32 as ip2IfStatRxSignaling  
  Counter32 as ip2IfStatRxVoice  
  Counter32 as ip2IfStatRxHdlc  
  Counter32 as ip2IfStatTxSignaling  
  Counter32 as ip2IfStatTxVoice  
  Counter32 as ip2IfStatTxHdlc  
  Counter32 as ip2IfStatRdnFlip  

Ip2IfPortEntry  
SEQUENCE    
  Integer32 as ip2IfPortIndex  
  Integer32 as ip2IfPortUsage  
  INTEGER as ip2IfPortMask  
  Integer32 as ip2IfPortTotalThroughput  

Ip2IfCurrentStatEntry  
SEQUENCE    
  Counter32 as ip2IfCurrentStatSeqErrors  
  Counter32 as ip2IfCurrentStatBufUnderflows  
  Counter32 as ip2IfCurrentStatBufOverflows  
  Integer32 as ip2IfCurrentStatMaxDelayVar  

Ip2IfIntervalStatEntry  
SEQUENCE    
  Integer32 as ip2IfIntervalStatIndex  
  Counter32 as ip2IfIntervalStatSeqErrors  
  Counter32 as ip2IfIntervalStatBufUnderflows  
  Counter32 as ip2IfIntervalStatBufOverflows  
  Integer32 as ip2IfIntervalStatMaxDelayVar